         Contents
1.                   17  10  TE NACA OA ee MM 18  IT  DIMENSION ee Um 20         USE OC ANON Ss ee en ee 21  13  Declaration of                                                                                  22    Manufactured and sold by     Kobold Messring GmbH  Nordring 22 24  D 65719 Hofheim  Tel    49 0 6192 2990  Fax   49 0 6192 23398  E Mail  info de kobold com    Internet  www kobold com    DMI 09 00    DMI    3  Specific Application    The DMI is to be installed only in the specified applications  Every usage which  exceeds the specifications is considered to be non specified  Any damages  resulting thereform are not the responsibility of the manufacturer  The user assumes  all risk for such usage  The application specifications include the installation  start up  and service requirements specified by the manufacturer     4  Operating Principles    The flowrates of liquids with a conductivity of at least 50 uS cm  can be measured with this flowmeter  Miniflow      Faraday s Laws of Induction state that a voltage is generated  which is proportional to the average flow velocity  This signal  voltage is measured at two electrodes which are in contact with  the fluid     Various signals are available at the outputs of the converter for  further processing  e g  flowrate proportional pulses  20 mA  current output  min  max  contact output for process monitor ing      The electrical connections are made with a plug     5  Instrument Inspection    These devices are checked be
2.      Electronic   Power supply   Ripple    Power consumption   Display    Electr  connection   Impulsausgang   fest eingestellt  Pulse width    Pulse frequency   Output signal     Page 18    PEEK or PETP   Hastelloy C   Hastelloy C   10 bar  over whole temp  range    25  C    110  C  PEEK     25     60     PETP     25        50       min  50 uS cm   3 x DN inlet   2 X DN outlet     3   f  r Q gt  0 07 x Q max      Q maxX 0 0021  f  r Q  lt  0 07 x Q max    Option    1 596 of actual range     lt  0 2  of actual range   adjustable 0 10   of   the adjusted range    Hysterisis 1     5s  step function 0 99     Adjustable between 5 40 Sec    61   4 Hz   IP 65  EN 60529   15 m s     max  axeleration at 10 150 Hz   series DMI don t have any parts loading into the  measuring tube  The pressure loss disregardingly  small     16 8 31 2 VDC or 16 8 26 4 VAC  5 96     5W   3 line  97 x 32 pixel    plug in DIN 43650   1 pulse   Liter  Gallon     20 ms    max 20 Hz  0 or 4 20 mA  adjustable   Load  lt  600 Ohm    DMI 09 00    DMI    Optocoupler  The opotcoupler output can be set either as a pulse output or switch output   a  Pulse output passive     Optocoupler     Voltage  16  lt  0       lt  30V 0V lt Uce  lt 2 V    Current           lt Icen lt  0 2        2 mA  lt  1          220 mA           frequency  20 pulses sec    Pulse width  fixed 20 ms   or   b  Switch output   Function adjustable  Example  forward backflow switching  min max  contact  system alert   Technical data optocoupler  
3.     Arrow keys are used to scroll forward throught the menus  All    desired parameters can be accessed    9  The ENTER function requires that both of the arrow keys  be    pressed simultaneously  ENTER is used to turn the program  protection on and off to change and fix new parameter values     Page 12 DMI 09 00    DMI    8 3  Data Entry instructions    Condensed Form     Action use keys   Display Information  Starting poini     y 233 55  Process intormation  min     SET  Example     Flowrange setting         arbitrary parameter  Omax is displayed    Find Pararneler      Program Protection     Prog  Protection    on          Program Protection       Program Protection   of  Direct Numeric Entry Entry from a Table  Action use keys   Display Inform  Action use keys   Display Inform   Find arrow kay m  233 55 Find arrow key   Submenu  Parameter    subrnenu  mar    0 nd    currant output    LOUPE HN    Change   Change   m   Pie      t    Parameter ENTER  t    Cmax   Parameter ENTER  t  0 20mA                      turrenti             me l min  Change tram   2 Current output  B io 4 20 mA EH         _ Wm      JH   6x    find desired TAT   Current output    currant            4 20 mA   Emer the   desired    numbers in accept new    Sequere current nulpit  Ex 2 value ENTER   Current output    4 20mA    accepi new Oma  Gmax value ENTER ER    620 imin    Exit from Omay  Program Protection   Find Parameter v    off  Prog  Protection    Turn Prag  Pratecbon   Program Protection     on 
4.   If DMI should measure only in one flow direction  a  straight pipe section of 3 x DN upstream and 2 x DN downstream is required  If DMI  should measure in both flow directions  3 x DN straight pipe section upstream and  downstream is required        Page 4 DMI 09 00    DMI    Valves or other shutoff devices should be installed downstream form the flowmeter  so that it connot drain        A slight slope in the pipeline of approx  3   is advantageous in eliminating gas  pockets in the flowmeter        Installations in vertical pipelines are ideal when the fluid flows up  Installation in drop  lines  i e  the fluid flows from the top to the bottom should be avoided because it is  impossible to assure the flowmeter will remain full due to an equilibrium condition  which may exist between the downward flowing fluid and gas being forced upward        DMI 09 00 Page 5    DMI    In general the flowmeter should be installed in the pipeline with the PG Connectors  facing down     When installed in a horizontal pipeline the imaginary line between the two electrodes  should be horizontal if at all possible to prevent air or gas bubbles from interfering  with the flow signal which is measured at the electrodes  The position of the  electrode axis is shown in the adjacent figures     Electrode  axis       Entrained gas bubbles carried along with the fluid cause flow measurement errors     When installed in free discharge lines the flowmeter should not  be located in the high point in the
5.  of the flow range setting       alarm will  nurmarkc always be indicated in the display  An output signal can only be  obtained e m the submenu  Prog oulpul Min  Alarm  Max  Alam  or Min Max  Alarm was selected  Deim value Gr fis Alm im 0 oe   Pinning see connection diagram  Switching mystereses  1          DMI 09 00 Page 15    DMI      Submenu Parameter Entry Type i Comments    Selectable 0 20 mA or 4 20 mA  E Dalasa   8    4 20 ma     Exit the submenu  1  or    fix new selection with    with 4 20 mA the current output during alarm condition can be set  tn     mA  3 6 mAs 21 m     with 0 20 mA the current output during alarm condition can be set  to  O mA  21        Dale Eve deut al darem      LT m      lout at Alarm    The totalizer in the display indicatas the forward and tha reverse  tatalizar as a single value     The totalizer can be reseted to zero by pushing  Lo    Exit the submenu  1     Manual adjustment of system zero    Valve must be closed  Flowmeter must be full and flow must be at  zero  The automatic zero adjustment is limited by pressing Enter   The limit for the zero adjustment is   50 Hz  If the zero automatic  System zero adj  exceeds this value no adjustment is made  The value determined  by the converter is displayed in the 2nd ling    Exit the submenu        Select if flowrate should ba indicated in   or in engineering units  in the display  Switch over from   tn the engeneering unit selec   ted in the submenu    Unit        fix new selectian with Ente
6.  pipeline or at the outlet end of  the pipeline  flowmeter drains  gas bubbles      Standing eddies  after partially open valves or when there are  tangential inflows upstream of the flowmeter  which persist into  the flowmeter should be avoided     If a pump is used to produce the flow the flowmeter should be    Page 6 DMI 09 00    DMI    installed on the pressure side of the pump     In mixing systems  the flowmeter should be installed in a location  where the complete mixing has taken place  Non homoge neous  fluid conditions in the flowmeter are to be avoided    Pulsation dampers should be utilized where required     The ground connection between the two plugs on the converter  housing is to be connected to a good ground     There are grounding electrodes integrated in the meter tube in  the flowmeter     The meter tube and the electrodes integrated in the meter tube  come in contact with the fluid  Check before start up that the  materials used are chemically resistant to the fluid being measured   Gaskets should be used when installing the flowmeter    These should also be compatible with the fluid being metered     Assure that the maximum temperature will not exceed the fol lowing  values     a  For meter tubes made of PEEK max  110   C  b  For meter tubes made of PETP max  60   C    The meter tube material is listed on the Instrument Tag on the  flowmeter     Observe the max  torque values when tightening the connectors on the DMI    Torque Specifications for process 
7. Operating instruction  for    Electromagnetic Flowmeter    Model  DMI       DMI    1  Note    These instruction are to be read before unpacking and operating the device and are    to be closely heeded at all times     The devices are only to be used  maintained and serviced by persons familiar with  these operating instructions and with the prevailing regulation applying to procedural    safety and the prevention of accidents     2  Contents    Page 2    ls NO eare E      2      Ge T ee 2  3  SPECINE ABBICA ON ee ee                    3  4  Operating                                                                        3  5  Instrument InSDOCllOD uceasierserers vacui ku ravra                        ku eani d 3      Mecnamcal COMME CUO e TTE 4  6  WIINSTAN ATION        Stall Deine nee 4  7   _EICCUGAl CONNECH OM anne 9  7 1  Signal Outputs and supply                                                                    9  7 2  Grounding                                                          9  7 3 Interconnection Diagram                                                 10                AOU RET 11  8 1  Overview of the Factory Settings in the converter                             11                            ETT  11  8 3 Data Entry instructions    Condensed                                                     13  8 4  Data Entry                                                                     14  9  Mechanical putting into                                                     
8. again   Jf   Exit point Process   V 233 55  information GCoryarter l min  remains online   WV 32251    DMI 09 00 Page 13    DMI    8 4  Data Entry Instructions    Submenu Parameter Entry    table    Prog  Protection      off    tabla    lable  andy for Info    numeric       fable                     Aci     numeric       table               u   m zer                  14              m               rs     Teg                  Comments    ON OFF  Data can only be entered after the Prog  Protection has  been turned off  Exit the submenu  1     German English     Dela La abe oy e Creer     Select preferred language by used of arrow keys and fix new    selection with    DN 10  15  25  50  see tag    Widest measuring range the meter can be set to  Automatic  setting based on the flowmeter size selection     Flow range for forward and reverse flaw directions    Dalaran iz Aangel   mir  flow range setting 0 0 5 m s  max  flow range setting 0 10 m s  The engineering unit is to be set in the submenu    Unit       Vs  l min  bh  galis            galfi               s nmn     Range  5 to 40 seconds                 is 5 sec      Range 0 10   of the selected flow range end  Affetcs to the display  indication amd all outputs  The switching point for the how cutoff    incorporates a hysteresis of 0 5 55    Dalauit vetve for ow flow culalf io T 95     External zero ratum or totalizer reset or without function  This sub   menu will only be displayed if this option was ordered  If this  functi
9. connection  on PETP       Avoid usage of ferromagnetic process connectors     DMI 09 00 Page 7    DMI    Page 8       Information for using the threaded Adapters  a  Flowmeter is installed in a plastic pipeline     DN Suitable for plastic Threaded Connection at Miniflow for  pipelines with  2 outside Plastic Pipelines    G 3 4  no threaded adapter     G 1  with threaded adapter G34 G1   G1 2  with threaded adapter G1 4 G1 12    234  with threaded adapter G2V2 G2         Example   The DMI is to be installed in a plastic pipeline with a 20 mm outside diameter     The above table indicates that a 1 2    DN 15 meter size is required  The adapter  shipped with the flowmeter must be used  This increased the    34  thread on the  flowmeter to G 1    so that the coupling union  which has a    1    thread size for size  plastic pipeline  can be connected to the flowmeter     b  Flowmeter is installed in a metal  e g  copper  pipeline    DN Suitable for plastic Threaded Connection at DMI for Metal  pipelines with   outside pipeline    14 mm     2  tubing G 3 4  no threaded adapter     18 mm   3   tubing G 3 4  no threaded adapter     28 mm   1  tubing G1   no threaded adapter        54 mm   2  tubing  221  no threaded adapter   Example    The DMI is to be installed in a metal pipeline with a 14 mm outside diameter  i e  1   2     metal tubing     The above table indicates that    3 8      DN 10 meter size is required  The adapter  shipped with the flowmeter must be removed since it is 
10. fore despatch and sent away in perfect condition   should the damage to a device be visible  we recommend a thorough inspection of  the delivery packing  In case of damage  please inform your parcel service   forwarding agent immediately  since they are responsible for damages during  transit     Scope of delivery   e Magnetic Inductive Flowmeter  e Service manual    DMI 09 00 Page 3    DMI    6  Mechanical connection    The DMI incorporates a threaded process connection  The  diameter difference of the transition from the pipeline to the  flowmeter should be kept to a minimum    For this reason additional threaded adapters  are mounted on  the flowmeter and shipped together  exceptions  flowmeter size  3 8    DN10 and flowmeters with NPT threads      These adapters provide the ability to install the flowmeter using   a coupling union either in plastic pipelines  using the threaded  adapter  or to install it in copper or other metal pipelines  by re moving  the threaded adapter and connecting directly to the   threads on the flowmeter     see the following Table for an overview     6 1  Installation and start up    The DMI should not be installed in the vicinity of strong electromagnetic fields  The  installation orientation is arbitrary  It is essential that the flowmeter always be  completely filled with fluid  Partial filling results in measurement errors        The DMI measures in both flow directions  The forward flow direction is shown by the  arrow on the meter primary
11. on i amp  available 20 mA            will be omitted then    Note  If  the name tag indicates a   Variant  5  this option is available                   for Prog  input je                  DMI 09 00    DMI       Selectable as pulse output or forward reverse flow direction signal  or Min  Alarm  Max  Alarm  Min  Max  Alarm  General Alarm  No  Function  Note  In conjunction with pulse output  internal setting  are  1 pulse per liber ar per gallon  pulse width 20 ms          pulse  frequency 20 Hz    Ciia for Peng               oul       General alarm       Pulse weight selectable  0 1 pulse or 1 pulse or 10 pulses    Pulse entny fram tabla per litre     only for infor  no settings possible  Automatic setting of pulse  only for info weight based on adjusted flaw range On Off ratio 1 1  pulse on  width   off width  if pulse width is within 2550 ms imax  pulss   width  and within 20 ma  min  pulse width    If other pulse width is required  change pulse weight or flow  range  Calculation of pulse width  30    Omax x pulse weight     pulse width in seconds insert Gmax in limin and pulse weight in  pulse Liter in above equation   Limit alarm  range 0 105 75 of the ow range Selling  An alarm wall  numere always be indicated in the display  An output signal can only be  obtained if in the submenu Prog output  Min  Alarm  Max  Alarm  or Min  Max  Alarm was selected  Detaut vaius tor Max Aim i 105      Pinning see connection diagram  Switching hystereses  1 ts  Limit alarm  range 0 105  
12. only required for installations  in plastic pipelines  With the threaded adapter removed the 3 8    DN 10 flowmeter  size has a    34    threaded connection  This is the connection size required for the G  34  coupling union used with the 12    metal tubing     DMI 09 00    DMI    7  Electical connection    7 1  Signal Outputs and supply power    Wiring  otandard DIN 43650 plug connector with PG 9 cable glands  pipe cross section  max  1 5mm        65 rating  Open plug and wire according following instructions     Three PIN Plug   Supply power  1 24 V AC DC  2 GND       Ground    Four PIN Plug   Signal Outputs   Pin 1 2 20 mA or contact input  option    Pin 3 4 Pulse   contact output  option     Also see Section    Interconnections  Peripherals         7 2  Grounding    When installing the flowmeter in a metal to the plug  Point A  together with the supply  power  left plug   then the connection at Point B must be at the same potential as at  Point A     Attention    If a ground connection is made to the plug  Point A  together with the supply power   left plug   then the connection at Point B must be at the same potential as at Point  A  If this cannot be assured then the ground should be connected at only one point      either in the plug  Point A  or externally to the flowmeter  Point B   If is recommended  that a ground be connected to Point B   See fig  11              LLL    Ta   e     Bes dE   Ground          oa                   Potential equalization only at metal pi
13. peline    DMI 09 00 Page 9       DMI    7 3  Interconnection Diagram    Interconnection Examples for Peripherals    Option     A   Pulse output  optocoupler   Pulse output  passive  and current output 0 4     20 mA or   optocoupler or contact output  passive    contact output passive  optocoupler optocoupler and current output 0 4   20 mA     internal axternal internal external  Ag      Ag       Pulse output Tai     Pulse output  contact output     ei contact output        Aa  gt            Pin  not used lee      04   20 mA    Pin 1 mot used       Option     B      Power supply  24 V AC DC    Pin 1L 24 V AC DC          2   GND    Function ground    Pin 4        Signal Output Specifications      The function assigned to the optocoupler of the signal output can be set in the  software  Function either as a pulse output or function as a contact output   Pulse output passive    Optocoupler specifications     16 V  lt U       lt  30           lt         x2 V    0 mA     l cep     0 2 mA 2 MA lt Ice       220 mA   fmax   20 pulse sec  pulse with 20 ms   or   Contact output passive  Optocoupler   The selection can only be made in the options with a display  In the    contact output  mode    one of the following signals can be set     Current output  selectable 0 4 to 20 mA  Burdon x 600 Ohm  Power supply  16 8   26 4 VAC bzw  16 8   31  2 VDC  Ripple  5    Power consumption   lt 5W    Page 10 DMI 09 00    DMI    8  Configuration    8 1  Overview of the Factory Settings in the conver
14. r or  ax submenu wilh       Current output settings during an alarm condition    Page 16 DMI 09 00    DMI    submenu Parameter Entry Type   Comments        This features is being used to check the 20 mA loop and to check  lee pulse output loop  The meter will mol be Online  amp  simulation is  set to on  The 20 m   signal and the pulse output will correspond  to the settings done by arrow keys  If simulation is turned on the  flowrate value has      be entered in  5 and to be fixed with ENTER   After press      to return to process display  The display then  shows simulation     The Minilow is longer online mow  By pres   ging the amor key the flowrate can now be increased or  decreased  After completion of the simulation program the para   meter  Simulation  must be tumed aff     Simulation       DL 5000 anao Data of the software being used  D  egacogauo1              For ABB Service only        9  Mechanical putting into operation    Gas pockets  It has to be accertained that the instrument is always completely filled with fluid   Partial fitting as well as gas pockets results in measurement errors     DMI 09 00 Page 17    DMI    10     Technical data    Materials   Body   lining   Electrodes   Ground electrode   Max  pressure     Max operating Temperature      Ambient Temperature   Conductivity    Inlet and outlet    recommended   Accuracy     Repeatability   Creep suppression     Response time     Frequency of excitaion   Protection    Vibration resistance   Pressure loss
15. see pulse output   Error signal  The switch output  optocoupler  can be set as a    system alert    Measurment error under reference condition   Pulse output     a  9       e  cd  j  m   o         IL Calibration       Veios    0 5 0 7 1 0  m s       DMI 09 00 Page 19    DMI    For Q maxon     shedule below     50 l min    100 l min  300 l min       1200 l min    11  Dimensions    Page 20    DMI   02    DMI   04    DMI   06    DMI   08    97    ca  51       DMI 09 00    DMI    12  Fuse Locations    Location of fuse on the signal input PCB board       DIP switch    Lo for range setting  20mA  damping  etc     Fuse for Power  supply 500 mA T    DMI 09 00 Page 21    DMI    13  Declaration of conformance    We  Kobold Messring GmbH  Hofheim Ts   Germany  declare under our sole  responsibility that the product    Electromagnetic flowmeter Type  DMI       to which this declaration relates is in conformity with the standards noted below     EN 50081 1 3 93  EN 50081 2 3 94  EN 50082 1 3 93  EN 50082 2 2 96    following the provision of European Directives   89 336 EWG    Signed        Datum  10 10 00  H  Peters M  Wenzel    Page 22 DMI 09 00    
16. ter    The DMI is shipped form the factory with preset values  The factory settings can be  changed at the flowmeter installation site   The following table provides an overview of the factory settings     Factory settings   Flow range  DN 10 50 l min  DN 15 100 l min  DN 25 300 l min  DN 50 1200 l min    8 2  DMI configuration       The converter can now be configured using menu structured clear text displays     e Flow range and damping can be set in an infinite number of steps    e Additional direct reading units can be user selected for the flowrate  measurements    e  he function assigned to the optocoupler for the pulse output can be changed    e g  min  alarm  max  alarm etc      Flow Range Table    DN   Flow Range in l min can be set anywhere between              DN   Flow Range in Usgal min can be set anywhere between           DMI 09 00 Page 11    DMI    Display format  The display of the DMI magmeter is a graphic display with 97 32 pixel     Display view   The flowrate is displayed in the upper display line  The difference totalizer  which  indicates forward and reverse flow as a single value  is shown in the lower display  line  Alarms will be displayed in clear text        Data entry   During data entry the converter remains on line  the current and pulse outputs  continue to indicate the instantaneous operating values  The function of the  individual keys is described below     Clear key is used to toggle back and forth between the operating  mode and the menus 
    