Agilent Technologies 85103G Service Kit CRT Display
Contents
1. 8341 and 8350 series sources are out of support life and are no longer recommended for use in 8510C systems Please consult with your Agilent customer engineer for more information on upgrading a network analyzer and source firmware Procedure Overview Step 1 Check the service kit contents Table 1 lists the contents of the service kit If an item is missing refer to Contacting Agilent on page iv for assistance Step 2 Assemble items not included in the service kit If needed obtain the reguired items listed in Table 2 that are not supplied in the service kit Step 3 Be sure you have a static safe work station Check for the following e The static mat sits on a clean flat sturdy surface e The static mat has a connection to earth ground e The static mat has a wrist strap connected to it Step 4 Remove the 85101C from the system 2 85103G Service Kit Installation Manual 8510C CRT Display Replacement Service Kit The Service Kit Step 5 Transfer the Time Domain IC Option 010 Step 6 Install the new 85101C into the system Step 7 Check the 8510C and Time Domain option if transferred Step 8 Recycle dispose of the replaced 85101C display processor Recycle or dispose of the 85101C display processor according to your state or local reguirements The battery on the A7 I O board and the A11 display CRT may have special reguirements When disposing of the cathode ray tube CRT observe the following preca
2. 10800 650 0121 India tel 1 600 11 2929 fax 000 800 650 1101 WARNING CAUTION Safety and Regulatory Information Review this product and related documentation to familiarize yourself with safety markings and instructions before you operate the instrument This product has been designed and tested in accordance with international standards The WARNING notice denotes a hazard It calls attention to a procedure practice or the like that if not correctly performed or adhered to could result in personal injury Do not proceed beyond a WARNING notice until the indicated conditions are fully understood and met The CAUTION notice denotes a hazard It calls attention to an operating procedure practice or the like which if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met Instrument Markings When you see this symbol on your instrument you should refer to the i j instrument s instruction manual for important information 4 This symbol indicates hazardous voltages ry N279 The C tick mark is a registered trademark of the Spectrum baud Management Agency of Australia FW This symbol indicates that the instrument reguires alternating current ac input The CE mark is a registered trademark of the European Community I
3. 8510C CRT Display Replacement Service Kit Checking the 8510C Checking the 8510C Turn on the instruments in the following order 1 Source make sure that the switch is turned to power on and not standby 2 Test set 3 85102 IF detector 4 85101C display processor Does the analyzer display any internal self test failure on the self test status LEDs or display If not the instrument passed the internal self tests and functions fully If a self test fails or a running error is displayed refer to the Agilent Technologies 8510C On Site Service Manual Checking Time Domain Option If Transferred Check that the time domain IC has been installed properly in the new 85101C 1 On the 85101C a Press INSTRUMENT STATE RECALL MORE FACTORY PRESET b Press MENUS DOMAIN and select TIME LOW PASS Does the instrument display the Set Freguency low pass menu If so the time domain option is installed properly If not recheck the installation of the IC 85103G Service Kit Installation Manual 11
4. WILL CONTROL Assistance Product maintenance agreements and other customer assistance agreements are available for Agilent Technologies products For assistance refer to Contacting Agilent on page iv Contacting Agilent Any adjustment maintenance or repair of this product must be performed by gualified personnel Contact Agilent for assistance Online assistance www agilent com find assist United States tel 1 800 452 4844 or 1 800 593 6635 for on site service of systems Latin America tel 305 269 7500 fax 305 269 7599 Canada tel 1 877 894 4414 fax 905 282 6495 Europe tel 31 20 547 2323 fax 31 20 547 2390 New Zealand tel 0 800 738 378 fax 64 4 495 8950 Japan tel 81 426 56 7832 fax 81 426 56 7840 Australia tel 1 800 629 485 fax 61 3 9210 5947 Singapore tel 1 800 375 8100 fax 65 836 0252 Malaysia tel 1 800 828 848 fax 1 800 801 664 Philippines tel 632 8426802 tel PLDT subscriber only 1 800 16510170 fax 632 8426809 fax PLDT subscriber only 1 800 16510288 Thailand tel outside Bangkok 088 226 008 tel within Bangkok 662 661 3999 fax 66 1 661 3714 Hong Kong tel 800 930 871 fax 852 2506 9233 Taiwan tel 0800 047 866 fax 886 2 25456723 People s Republic of China tel preferred 800 810 0189 tel alternate 10800 650 0021 fax
5. located on the A7 I O board of the 85101C display processor This battery is not field replaceable Replace the A7 I O board if the battery reguires replacement Danger of explosion if battery is incorrectly replaced Replace only with the same or eguivalent type recommended Discard used batteries according to manufacturer s instructions DO NOT THROW BATTERIES AWAY BUT COLLECT AS SMALL CHEMICAL WASTE vi Italics Instrument Display Keycap Softkey User Entry Path name Computer Display Typeface Conventions Used to emphasize important information Use this software only with the Agilent Technologies xxxxxX system Used for the title of a publication Refer to the Agilent Technologies xxxxxX System Level User s Guide Used to indicate a variable Type LOAD BIN filename Used to show on screen prompts and messages that you will see on the display of an instrument The Agilent Technologies xxxxxX will display the message CAL1 SAVED Used for labeled keys on the front panel of an instrument or on a computer keyboard Press Return Used for simulated keys that appear on an instrument display Press Prior Menu Used to indicate text that you will enter using the computer keyboard text shown in this typeface must be typed exactly as printed Type LOAD PARMFILE Used for examples of programming code tendif ifndef NO CLASS Used for a subdirectory name or file path Edit the file usr
6. 010 1 Remove the top cover of the old 85101C display processor CAUTION Static electricity can damage this assembly Wear an anti static wrist strap connected to earth ground Place the instrument top cover connected to earth ground near the work area with the bare metal side facing up When you must put them down place assemblies on the metal surface Figure 1 A8 Assembly Location A8 ASSEMBLY Jp503 2 Remove the A8 assembly by grasping the knob on the A8 assembly board and pulling outward and upward Remove the Time Domain IC part number 85101 80091 from the A8 assembly board and set it aside for installation in the new 85101C 3 Replace the A8 assembly and the top cover of the 85101C 6 85103G Service Kit Installation Manual 8510C CRT Display Replacement Service Kit Transferring the Time Domain IC Option 010 On the new 85101C 1 Remove the top cover of the display processor 2 Remove the A8 assembly by grasping the knob on the A8 assembly board and pulling outward and upward Refer to Figure 1 for the A8 assembly location 3 Insert the Time Domain IC p n 85101 80091 in an empty socket on the A8 assembly see Figure 2 Figure 2 IC Installation Location on A8 Assembly IC Sockets A8 Assembly jp501j 4 Replace the A8 assembly Push down firmly on the board and inward on the knob until it snaps in place 5 Replace the top cover of the 85101C 6 With an indelible pen write OPT 010 be
7. Agilent Technologies 85103G Service Kit CRT Display Replacement for the 8510C Network Analyzer Installation Manual a Agilent Technologies Manufacturing Part Number 85103 90015 Printed in USA November 2002 Supersedes August 2001 Notice The information contained in this document is subject to change without notice Agilent Technologies makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability and fitness for a particular purpose Agilent Technologies shall not be liable for errors contained herein or for incidental or conseguential damages in connection with the furnishing performance or use of this material Agilent Technologies assumes no responsibility for the use or reliability of its software on eguipment that is not furnished by Agilent Technologies This document contains proprietary information which is protected by copyright All rights are reserved No part of this document may be photocopied reproduced or translated to another language without prior written consent of Agilent Technologies Restricted Rights Legend Use duplication or disclosure by the U S Government is subject to restrictions as set forth in subparagraph c 1 ii of the Rights in Technical Data and Computer Software clause at DFARS 252 227 7013 for DOD agencies and subparagraphs c 1 and c 2 of the Commercial Computer Software Restricted Rights claus
8. e at FAR 52 227 19 for other agencies Agilent Technologies 1400 Fountaingrove Parkway Santa Rosa CA 95403 1799 U S A Copyright Agilent Technologies 2001 2002 Certification Agilent Technologies certifies that this product met it s published specifications at the time of shipment from the factory Agilent Technologies further certifies that its calibration measurements are traceable to the United States National Institute of Standards and Technology NIST formerly NBS to the extent allowed by the Institute s calibration facility and to the calibration facilities of other International Standards Organization members Warranty THE MATERIAL CONTAINED IN THIS DOCUMENT IS PROVIDED AS IS AND IS SUBJECT TO BEING CHANGED WITHOUT NOTICE IN FUTURE EDITIONS FURTHER TO THE MAXIMUM EXTENT PERMITTED BY APPLICABLE LAW AGILENT DISCLAIMS ALL WARRANTIES EITHER EXPRESS OR IMPLIED WITH REGARD TO THIS MANUAL AND ANY INFORMATION CONTAINED HEREIN INCLUDING BUT NOT LIMITED TO THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR PURPOSE AGILENT SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEGUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING USE OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN SHOULD AGILENT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS THE WARRANTY TERMS IN THE SEPARATE AGREEMENT
9. ed The new 85101C display processor comes preloaded with the proper 8510C operating system If needed the operating system can be reloaded using the procedure below This procedure for loading the operating system differs from the usual disk loading procedure This method allows you to load a disk with or without an operating system previously loaded in the analyzer and reguires fewer keystrokes Selecting the appropriate operating system CRT or LCD version supplied in the upgrade package will ensure that the proper operating system is loaded The time domain option firmware is included in both 8510C operating system versions and is enabled by the time domain option security key IC Procedure 1 While holding down the MARKER key turn on the system instruments in the following order a Source turn the switch to power on not standby b Test set c Analyzer This causes the instrument to detect an apparent keyboard failure and display self test error 14 subtest 2 Ignore this error 2 Press MARKER again 3 Insert the operating system disk into the analyzer disk drive and press 1 9 MARKER 4 Select the file named PG 8510C then select LOAD FILE The disk loads in three to four minutes and the system begins normal operation The screen displays S11 Log Mag 5 Press INSTRUMENT STATE RECALL and select MORE FACTORY PRESET 6 Continue with Checking the 8510C 10 85103G Service Kit Installation Manual
10. f it is accompanied by a year it indicates the year the design was proven The CSA mark is a registered trademark of the Canadian Standards She Association 1SM1 A This text indicates that the instrumentis an Industrial Scientific and Medical Group 1 Class A product CISPER 11 Clause 4 ICES NMB 001 This ISM device complies with Canadian ICES 001 Cet appareil ISM est conforme a la norme NMB 001 du Canada zo This symbol indicates that the power line switch is ON This symbol indicates that the power line switch is OFF or in Ll STANDBY position J WARNING Safety Earth Ground This is a Safety Class I product provided with a protective earthing terminal An uninterruptible safety earth ground must be provided from the main power source to the product input wiring terminals power cord or supplied power cord set Whenever it is likely that the protection has been impaired the product must be made inoperative and secured against any unintended operation Before Applying Power Verify that the product is configured to match the available main power source as described in the input power configuration instructions in this manual If this product is to be powered by autotransformer make sure the common terminal is connected to the neutral grounded side of the ac power supply Battery Information The 8510C uses a lithium polycarbon monoflouride battery to power the instrument clock The battery is
11. itter Semirigid cable Semirigid cable 08510 20005 08510 20006 a Except for an 9826A b From an 8510 service kit or 85114A test set 85103G Service Kit Installation Manual 8510C CRT Display Replacement Service Kit Removing the 85101C Display Processor Removing the 85101C Display Processor Procedure NOTE Before replacing the 85101C display processor be sure to save any custom instrument states and calibration kit definitions to disk This can be done by performing a machine dump Refer to the 8510C Operating and Programming Manual for this procedure 1 At a static free workstation check that a The static mat sits on a clean flat sturdy surface b The static mat has an earth ground connection c The static mat has a connected wrist strap 2 Remove the 85101C display processor from the system 3 If the 85101C display processor that is being replaced is currently equipped with time domain Option 010 continue with Transferring the Time Domain IC Option 010 Otherwise install the new 85101C display processor into the system and reconnect all cables and line cords Refer to Reconnecting the System on page 9 85103G Service Kit Installation Manual 5 8510C CRT Display Replacement Service Kit Transferring the Time Domain IC Option 010 Transferring the Time Domain IC Option 010 If the 85101C display processor that is being replaced is currently eguipped with time domain Option
12. local bin sample txt Used to show messages prompts and window labels that appear on a computer monitor The Edit Parameters window will appear on the screen Used for menus lists dialog boxes and button boxes on a computer monitor from which you make selections using the mouse or keyboard Double click EXIT to guit the program vii viii 8510C CRT Display Replacement Service Kit 8510C CRT Display Replacement Service Kit The Service Kit The Service Kit This service kit installation manual details the steps reguired to replace the CRT display of the 85101C display processor top box of an 8510C system or an 8510XF E7340 50A system Warranty Information Installation of the service kit does not affect the existing instrument warranty in any way Specifically it does not extend the current instrument warranty Any parts supplied in the service kit carry a 90 day replacement part warranty Source Compatibility For complete compatibility with revision C 07 00 or greater firmware your source must be an Agilent 8360 series source If an 8360 series source is not used power domain and receiver calibration functions will not work The 8510C works with all 8360 synthesized sweeper models However some 8360 instruments must be upgraded to take advantage of two 8510C system features guick step mode and test port power flatness correction Refer to Upgrading an 8360 Source on page 8 NOTE Agilent 8340
13. low the serial number on the new 85101C 7 Install the new 85101C display processor into the system 8 Continue with Upgrading an 8360 Source next 85103G Service Kit Installation Manual 7 8510C CRT Display Replacement Service Kit Upgrading an 8360 Source Upgrading an 8360 Source Refer to the chapter Main Troubleshooting Procedure in the 8510C Network Analyzer On Site Service Manual p n 08510 90282 After upgrading source s continue with Reconnecting the System 8 85103G Service Kit Installation Manual 8510C CRT Display Replacement Service Kit Reconnecting the System Reconnecting the System Install the new 85101C display processor into the system and reconnect as shown in Figure 3 For a typical system reconnect the GPIB Display Interconnect and line cord to the new 85101C display processor Figure 3 Typical 8510 System Connections GPIB GPIB NETWORK ANALYZER SOURCE DISPLAY INTER CONNECT TRIGGER IN 8360 SERIES ONLY SWEEP IN 0 10V SWEEP NOT USED FOR 8360 SERIES OUTPUT STOP SWEEP IN OUT STOP SWEEP TEST SET TEST SET INTERCONNECT SOURCE MODULE INTERFACE SOURCE CONTROL CABLE 8516A ONLY RF FROM SOURCE POWER SPLITTER HAS 3 5mm F jp502j 85103G Service Kit Installation Manual 9 8510C CRT Display Replacement Service Kit Loading the 8510C Operating System If Needed Loading the 8510C Operating System If Need
14. utions WARNING The CRT can pose a shock hazard if not properly discharged Explosion or implosion of the CRT may cause persona injury Only a properly trained individual should release the vacuum Table 1 Service Kit Contents Item Quantity Model Part Number 85101C display processor 1 85101C Cables 85101C cables p o 85101C BNC 2 GPIB 1 IF Display Interconnect 1 RS 232 1 Documentation 85103G Service Kit Installation Manual 1 85103 90015 p o 85101C 8510C Manual set contains 08510 90275 8510C Keyword Dictionary 1 08510 90280 8510C Operating and Programming Manual 1 08510 90281 8510C On Site Service Manual 1 08510 90282 Software p o 85101C 8510C software kit 85101 60271 Performance verification disk 1 08510 10033 Master cal constants disk 1 08510 10034 Service adjustments disk 1 08510 10024 Software tool kit disk 1 85103 10002 Operating system disk for 8510C 1 85101 80116 Operating system disk for 8510XF E7340 50A 1 E7340 10001 85103G Service Kit Installation Manual 3 8510C CRT Display Replacement Service Kit The Service Kit Table 2 Eguipment Reguired but Not Supplied Item Agilent Part Number Source 8360 series Test Set 8511A B 8514B 8515A 8517A B or 85110A L Static control table mat 9300 0797 Wrist strap 9300 1367 Wrist strap to mat cord 5 ft 9300 1980 Disk drive 9122C Controller HP 9000 series 200 3002 or PC GPIB cables 10388A For 8511A Only 5086 7408 Power spl