Home
        Balance Hybrid Service Manual
         Contents
1.            7 6 22M odule  Module Sense L ev 2             Description  This indicates the loss of 2 or more of the 4 battery module temperature sensors  in the pack   Temperature data for that section of the pack is invalid   Possible Causes  M ultiple internal battery pack module temperature sensor or wiring failures   Diagnostic Aids  e Replace ESS                7 6 23C ritical  State of C harge  SOC     Description  The ESS state of Charge has went above 95  SOC or below 5  SOC  This  does not necessarily mean there is a battery issue           Possible Causes  e Pack SOC is too high or too low    e Hybrid systems is overcharging or over discharging pack  V CU  software  traction motor  ISG motor  dc dc converter  EPAS  Air  Condition         Diagnostic Aids  e Check for other VCU DTC s before continuing  e Most likely not an ESS failure but a vehicle fault                 Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 147    AZD Service Manual    7 6 24C ritical  Control Parameter    Description  The following conditions have occurred at the same time   e Keyln FALSE       e CAN Link Lost Fault  TRUE       POSSIDIE CAUSES e Disconnected pack CAN wiring OR pack microcontroller ignition  low    voltage connector pin    a      Unless this is intermittent  then pack will not be  able to restart or re enable high voltage     e Internal battery pack software fault  Replace pack        Diagnostic Aids  e  f ahistory fault  this can be ignored as it
2.           Description  The ISG DM oC state does not match the state being commanded by the VCU  The Body  Builder AC will be shut off and the engine will be forced on and stay running and the  HY BRID SERVICE light will be on solid   Possible e ISG DMOC was just reprogrammed with new software without the voltage  Causes  calibration being performed   e Faulty ISG DMoC   e Incorrect DM oC Software   Diagnostic e Compare the ESS buss voltage to the reported voltage from the ISG DM OC and  Aids     use ccShell to recalibrate DM oC voltage  Ensure that Save Box Config has been    performed   Voltage Calibration    DMoC Reported Voltage  V   324 02      Measured Voltage       _   calibrate  BoxConfiguration DCVoltageScaleFactor  T_INT C     2 4043   Save Box Config    Reprogram ISG DM OC with latest software from A zure   Contact A zure TechLine techline  azuredynamics com for support           POA1F  Battery Energy Control Module       Description     The ESS does not respond to a connect command from the V CU for greater than  2 seconds    The vehicle will be set to    Forced Conventional mode    and the HY BRID  SERVICE light will be on solid        Possible Causes     e ESS Isolation resistance is too low    less that 2 M ohms at key on   e Internal ESS failure        Diagnostic A ids           e Using Balance Diagnostic Tool check for any ESS Info codes  repair as  required    e Using the BDT verify that the isolation resistance of the ESS diagnostics  are 2 mohms at key on e
3.           e Use Balance diagnostic tool to monitor Accelerator Pedal Track 1  2  3  inputs    e Refer to appropriate A zure wiring schematics    e Refer to appropriate Ford Diagnostics for APP sensor track 2 signal        P0222   Throttle Pedal Position Sensor Switch    B    Circuit Low       Description     MY 2008  The VCU has detected that the A ccelerator Pedal track 2 input signal  to the VCU has a short Circuit to Ground or an Open Circuit  The input voltage is  less than 0 53 volts  If no faults are present on tracks 1  amp  3 then the vehicle will  continue to operate normally and the Hybrid Service light will be on solid    If faults are present for track 1  track 3 or both as well as the P0222  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash     MY 2009  The VCU has detected that the A ccelerator Pedal track 2 input signal  to the VCU has a short Circuit to Ground or an Open Circuit  The input voltage is  less than 0 14 volts    The vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash        Possible Causes     e APP Sensor track 2 wiring short circuit to ground   e Faulty APP sensor   e Open Circuit        Diagnostic A ids           e Refer to appropriate A zure wiring schematics and check all electrical  connections related to A ccelerator Pedal track 2    e UseBDT to monitor Accelerator Pedal track 2    e Refer to appropriate Ford Diagnost
4.       Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 139    AZD Service Manual    motor  DC to DC converter  EPAS  Air Con         e Pack modules are weak or poorly balanced   e Pack is cold  below 0  C      e Internal battery pack fault  module voltages are being misread due to  hardware or software fault         Diagnostic A ids  e Use Balance Diagnostic too   and record all faults  If a Critical SOC  fault is found refer to Critical  State of Charge  soc  first  e Confirm SOC is greater than 10                    7 6 14M odule  Over Voltage    Description  At least one of the module voltages in the battery pack is greater than or   16 0  volts and remains in this condition for 2 sec           GE e Hybrid system is over charging pack  V CU software  traction motor  ISG    motor     e Pack modules are weak or poorly balanced   e Pack is cold  below 0  C      e Internal battery pack fault  module voltages are being misread due to  hardware or software fault         Diagnostic A ids  e Use Balance Diagnostic too   and record all faults  If a Critical SOC  fault is found refer to Critical  State of Charge  SOC  fault first   e Confirm SOC is less than 90                    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 140    AZD    Service Manual    7 6 15M odule  Delta Voltage       Description     U Volts    Difference between average module voltage and maximum or minimum module   voltage exceeds predetermined level
5.    e Refer to appropriate Ford Diagnostics for APP sensor        P250A  Engine Oil Level Sensor Circuit       Description     The Engine Oil Level switch input to the VCU switches faster than max defined  frequency of 1 Hz        Possible Causes     Engine Oil Level switch Circuit   intermittent connection        Diagnostic A ids           e Use Balance diagnostic tool to monitor Engine Oil Level switch Input   e Refer to appropriate A zure wiring schematics and check all electrical  connections related to Engine Oil Level switch Input to VCU        P2519  A C Request    A    Circuit       Description     The Body Builder A C request input to the VCU switches faster than max defined  frequency of 25 Hz  The vehicle will continue to operate normally and the Hybrid  Service light will be on solid        Possible Causes     A C request   intermittent connection        Diagnostic A ids           e Use Balance diagnostic tool to monitor A C request Input   e Refer to appropriate A zure wiring schematics and check all electrical  connections related to A C request Input to VCU        P2533  Ignition Switch Run Start Position Circuit       Description     The K ey Start input to the VCU switches faster than max defined frequency of 5  Hz  The vehicle will continue to operate normally and the Hybrid Service light  will be on solid        Possible Causes     K ey Start circuit   intermittent connection        Diagnostic A ids           e UseBDT to monitor K ey Start input    e Confirm
6.   C    Minimum Stop Performance       Description  The accelerator pedal track 3 signal is below 9   The vehicle will continue to  operate normally and the Hybrid Service light will be on solid        Possible Causes  e APP track 3 short to ground   e APP track 3 connectivity   e APP sensor fault        Diagnostic A ids  e Refer to appropriate A zure wiring schematics   e Refer to appropriate Ford Diagnostics for APP sensor                 Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 110    AZD Service Manual    P2163  Throttle   Pedal Position Sensor    A    Maximum Stop Performance       Description  MY 2008  The accelerator pedal track 1 signal is above 91   If no faults are  present on tracks 2  amp  3 then the vehicle will continue to operate normally and the  Hybrid Service light be on solid    If faults are present for track 2  track 3 or both as well as the P02163  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and the   HY BRID SERVICE light will flash    Note  APP track 1 is an inverted signal when compared to tracks 2  amp  3    MY 2009  The accelerator pedal track 1 signal is above 98   The vehicle will be  set to a    Forced Conventional Limp Home M ode    and the HY BRID SERVICE  light will flash        Possible Causes  e APP track 1 short to ground   e APP track 1 connectivity   e APP sensor fault        Diagnostic A ids  e Refer to appropriate A zure wiring schematics   e Refer to appropriate Ford D
7.   M Y 2009  The accelerator pedal track 1 signal is below 2   The vehicle will be  set to a    Forced Conventional Limp Home M ode    and The HY BRID SERVICE  light will Flash        Possible Causes     e APP track 1 short to V bat or VREF   e APP track 1 connectivity   e APP sensor fault        Diagnostic A ids        e Refer to appropriate A zure wiring schematics   e Refer to appropriate Ford Diagnostics for APP sensor              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 109       AZD Service Manual    P2113   Throttle Pedal Position Sensor    B    Minimum Stop Performance       Description  MY 2008  The accelerator pedal track 2 signal is below 9   If no faults are  present on tracks 1  amp  3 then the vehicle will continue to operate normally and the  Hybrid Service light will be on solid    If faults are present for track 1  track 3 or both as well as the P02113  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will Flash   MY 2009  The accelerator pedal track 2 signal is below 2   The vehicle will be  set to a    Forced Conventional Limp Home M ode    and The HY BRID SERVICE  light will Flash        Possible Causes  e APP track 2 short to ground  e APP track 2 connectivity  e APP sensor fault       Diagnostic A ids  e Refer to appropriate A zure wiring schematics   e Refer to appropriate Ford Diagnostics for APP sensor                 P2114   Throttle Pedal Position Sensor  
8.   greater than  volt     One of the following conditions is TRUE for 20 seconds    e The average module voltage of the pack minus the minimum module  voltage is   2 5 volts   e Themaximum module voltage minus the average module voltage of the  pack is     1 2V    Average Volts    14 volts       2 5 volts 1 2 volts    Pack modules may be weak or poorly balanced  A single or multiple  modules may be failing or have failed    Internal battery pack fault  module voltages are being misread due to  hard or software fault    This may be more evident during cold  below 0  C  operation or during  aggressive operation where there are longer and heavier charge   discharge rates        Possible Causes     Pack modules are weak or poorly balanced  Replace pack   Pack is cold  below 0  C      Internal battery pack fault  module voltages are being misread due to  hardware or software fault         Diagnostic Aids        See pinpoint test below                       Test step Result   Action  1 Perform preliminary diagnostics   Yes  e Perform preliminary diagnostic section  Repair and retest   No  Go to step 2  Were any issues found   2 Check for Battery Faults and Software  Version  Yes  e KeyON  using the A zure Battery Diagnostic Diagnose any SOC faults  After repairs are complete              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 141       AZD Service Manual    Test step Result   Action  software  verify the latest software is loaded to   clear all 
9.  35m t R Dim SE   Molded  ans e Gi    L pen  LOWER     i Hose NIMH BATTERY PACK  L   0 52nt 1 Hose AP  5 psi   12 L min  Maided elbow HR   600 W  Max Inlet Temp   45  C  E   Si    H w Noes  Es 5 8  Hosa    Molded NOTES   Q    1  NOT TO SCALE  Es DEGAS 2  ARROWS INDICATE FLOW DIRECTION    TAEA 3  BLUE REFERS TO CO  D FLUID  ORANGE IS WARM  RED IS HOT  D    BOTZ 4  HOSE LENGTH TOLERANCE TO BE WITHIN at Dm  CAP v Hose  4 L 3 30m Ss d  Sg 4 in  The cooling system  as shown In this Satcon DC DC  diagram  to the Satcon DC DC Converter is CONVERTER  3a Vent Hose    not installed on P4 and P5  HR   455 W  L 042m     P4 and P5 use an alr cooled system instead is     Max Inlet Temp   55  C  UPPER  amp   d    LI  CRO  27 Hose Note  install lag  Molded Elbow    si Highest poai    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    AZD    Service Manual    POA92   Hybrid Generator Performance       Description  The ISG fails to crank engine above a calibrated threshold of 125 rpm 3  consecutive times  The HY BRID SERVICE light will be on solid  VCU will  attempt to start the engine with the starter  If both starter and ISG starts fail  the  HYBRID SERVICE light will flash and the vehicle will be set to Forced EV  mode with delayed traction disabled depending on the state of charge        Possible Causes  e    ISG motor failure    ISG DMoC failure   ISG belt failure    ISG belt slippage or failed belt tensioner   Speed sensor failed or intermittent        Diagno
10.  7 6 7 Misc  Invalid Pack State       Description  System has entered an invalid state       PER e Internal battery pack software fault        Diagnostic Aids  e Use Balance Diagnostic tool and record all faults    e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software                 7 6 8 Misc  Invalid Precharge State       Description  System has entered an invalid state       ROSSI CAUSES e Internal battery pack software fault        Diagnostic Aids  e Use Balance Diagnostic tool and record all faults    e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software                 7 6 9 Input  Default Param L oaded       Description  This fault indicates that the proper parameters were not loaded to the battery    during a software update  The system is operating using default values which  may affect the system operation           NOTE  This code will be set during battery programming and must be cleared          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    137                AZD    Service Manual       when programming is completed  Failure to clear the code may result in  unnecessary diagnostics        Possible Causes     e ESS was programmed and faults were not cleared  e ESS was programmed and parameters were not loaded       Diagnostic A ids           e Use Balance Diagnostic tool and record
11.  C310S D3 connectivity    e Refer to appropriate A zure wiring schematics and check all electrical  connections related to K ey Start Input to VCU           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 112                AZD Service Manual    U0100 ENG   Lost Communication with ECM PCM    A          Description  Fault monitoring begins 2 seconds after the PCM has been powered on by the  VCU  TheVCU will monitor the PCM CAN messages  If any PCM message is  arriving too slow  or any message is not being received at all  this fault will set   The vehicle will be set to    Forced Conventional Limp Home mode    and the   HY BRID SERVICE light will flash        Possible Causes  e External E Stop circuitry  short to ground    pre production only   e Failed Can  terminator resistor   e Failed PCM   e Faulty power and ground circuits to PCM module   e Faulty wiring  routing or connection problems on CAN 1        Diagnostic Aids  e Place vehicle in conventional mode and perform Ford base vehicle  diagnostics to confirm the PCM is operating normally    e UseBDT  Balance Diagnostic Tool  to manually enable PCM relay and  confirm V batt at Ford PCM fuse  23  at Ford under hood power  distribution panel     e Refer Azure wiring schematic   e Refer to pinpoint test procedure Loss of CAN 1 Communications                    U010F Lost Communication With Air Conditioning Module       Description  If any Traction M otor DM oC CAN message is arriving too slow  or 
12.  Description        The SW revision reported by the TM DMoC is NOT 4  The vehicle will be set             Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 116             AZD    Service Manual       to a    Forced Conventional M ode    and The HY BRID SERVICE light will be on  solid        Possible Causes     e TheTM DMoC has the incorrect software level loaded           Diagnostic A ids        e Reprogram the TM DM oC with the correct software level  Refer to  https   extranet azuredynamics com for the latest software version              U1030 Software Incompatibility With Air Conditioning Module       Description     The SW revision reported by the A C DM oC is NOT 4  The vehicle will be set  to a    Forced Conventional M ode    and The HY BRID SERVICE light will be on  solid        Possible Causes     e TheA C DMoC has the incorrect software level loaded           Diagnostic A ids        e Reprogram the A C DM oC with the correct software level  Refer to  https   extranet azuredynamics com for the latest software version              U1031 Software Incompatibility With Power Steering Control Module       Description     The SW revision reported by the EPAS DMoC is NOT 4  The vehicle will be set  to a    Forced Conventional M ode    and The HY BRID SERVICE light will be on  solid        Possible Causes     e TheEPAS DMoC has the incorrect software level loaded           Diagnostic Aids        e Reprogram the EPAS DM oC with the correct software 
13.  Engine Running  using the Azure  Battery Diagnostic software  check the  minimum and maximum module voltages    e Pack voltage divided by 28  the average  module voltage        Yes   Allow the system to charge the pack with no load  If the  voltages do not recover to within the limits  replace the  pack             e Subtract the minimum module voltage from the   No  average voltage Go to step 6  e Subtract the average module voltage from the  maximum module voltage   Are the results of the first greater than 1 2  volts or the second greater than 0 7V   Note  this would indicate weak modules   6 Check M odule V oltages Under Load   e Use the Balance Diagnostic software to record Yes    minimum and maximum module voltages   e Inasafe area  perform several heavy  acceleration and deceleration runs  Do not  violate any laws   NOTE  It is recommended that one person  drives while a second operates the software    e Save the trace   NOTE  save as raw data  It may be necessary to  send the recording to Azure Dynamics for  analysis     Does the Delta Voltage go higher than 1 2  volts for greater than 2 seconds        Replace the pack    No   No fault at this time  This may be an indication of a  weakening pack that may exhibit problems in colder  operation        Module Voltages  Maximum Module     Minimum Modk    7 6 16C ritical Delta V oltage                 Description           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450          143    AZD    S
14.  P0222   Throttle Pedal Position Sensor Switch    B    Circuit Low  84  P0223   Throttle Pedal Position Sensor Switch    B    Circuit High  86  P0224  Throttle   Pedal Position Sensor Switch    B    Circuit Intermittent       0   cect cette eeeeeees 86  P0226   Throttle   Pedal Position Sensor Switch    C    Circuit Range  Performance  87  P0227  Throttle Pedal Position Sensor Switch    C    Circuit Low  87  P0228   Throttle Pedal Position Sensor Switch    C    Circuit High  88  P0229   Throttle Pedal Position Sensor Switch    C    Circuit Intermittent A 88  P0504 Brake Switch    A      B    Correlation  dsivevusu tata edel Deg 88  P0531 A C Refrigerant Pressure Sensor    A    Circuit Rangelbertomance serere 89  P0705   Transmission Range Sensor    A    Circuit  PRNDL Input       ccssscesessscssssssesssssssseessrsesrsenes 89  P0915  Gear Shift Position Circuit Range Performance  ccceccecececeeeeeeeeeeececeeeneesieieteneneeeteneeeteees 89  POAOF Eng Engine Failed to Startiniame aaa aaia 90  POA1B  Drive Motor    A    Control Module  90  POA1E  Starter Generator Control Module AAA 91  POA1F  Battery Energy Control Module    91  POA3C  Drive Motor    A    Inverter Over Temperature    92  POA 3E  Generator Inverter Over Temperature    NENNEN 92  RRE Re ellene e 92  POA7E  Hybrid Battery Pack Over Temperature  93  POA 92   Hybrid Generator Performance    94  POAA6  Hybrid Battery Voltage System Isolation Fault 0c cceceseeetenetetseseeeteeeieieteneneteteeeteeeees 94  POAE1 Hybrid B
15.  Product Support   Techline Support        10   PS_FLT_DC_BUS UNDER VOLTAGE          Description        The DC bus voltage drops below the EE 2PSOffB at  The minimum Powerstage  Operating Threshold  typically 100 volts  while the power stage is enabled   Note that the battery voltage must be above EE2PSOnB at  typically 120 volts   before the powerstage will enable  Since in many applications the DM oC does  not receive an OFF signal  the HV bleeding away is anormal shutdown event   therefore this fault is only flagged if the DM oC was switching  torque was  commanded  when the DC Bus Voltage drops out  This fault is meant to  highlight abnormal shutdown sequences  it is really more a warning than a fault           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 123             AZD    Service Manual       Possible Causes     Abnormal shutdown sequence    Wrong or corrupt Software  calibration  Faulty HV battery   Faulty VCU control          Diagnostic Aids        Confirm the shutdown sequence for the DM oC was correct  with all  torque request being zeroed at least EE 2PSIdleT ime before the HV  dropped below EE2PSOffBat    e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software           11   PS_FLT_OVERSPEED       Description     The motor Controller has detected that the motor speed in RPM has exceeded  the calibrated limit of EE2PosOverspeed in the positive direction  or  
16.  Temperature sensor    e Failed sensor    e Motor has overheated due to blocked air flow to motor   Diagnostic A ids  e Check wiring for opens and shorts to ground     M easure resistance between C174P pin    G    and pin    H    pin of the 19 pin  connector at traction motor  A functioning sensor should read between   150K   and  250K e   room temperature    M easure resistance between C174P pin    U    and pin    V    pin of the 19 pin  connector at traction motor  A functioning sensor should read between  25K   and 45K     room temperature    Note  pins U  amp  V are not populated on all models of traction motor   Refer To Azure Wiring Schematic        P1A04  Drive Motor    A    Position  Sensor Transmission Output Speed Sensor    Correlation       Description  The motor speed reported by traction DM oC differs from the PCM reported OSS  by more than 1500 rpm  The vehicle will be set to a    Forced Conventional M ode     and The HY BRID SERVICE light will be on solid    The VCU will switch from using the Traction M otor OSS for the vehicle controls  and the Instrument Cluster speed display and instead use the PCM reported  transmission output shaft speed signal  OSS  and calculated vehicle speed                 Possible Causes  e Check traction motor speed sensor   e Speed sensor wiring issue   e Broken slipping traction motor drive coupler   Diagnostic A ids  e Using Balance Diagnostic tool and the ford IDS tool  monitor and    compare the OSS reading to the traction moto
17.  all faults  e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software           7 6 10Precharge  Positive R elay Short       Description     The battery pack current exceeded 5 0A when only the precharge contactor was  closed        Possible Causes     e Internal ESS fault       Diagnostic Aids           e Use Balance Diagnostic tool and record all faults  e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software           7 6 11Precharge  System Short       Description     The battery pack has detected a system short fault either because the link  voltage failed to rise or the current failed to decrease during the precharge  sequence  The system monitors how long it takes for the link voltage to rise to  the same level as the pack voltage and for the current flow to drop  This would  normally indicate an external short on the high voltage buss  A short will  prevent the voltage from achieving the proper level and cause the current to  continue to flow        Possible Causes           e Vehicle high voltage buss is shorted  positive to negative      e Component on high voltage buss is drawing current during precharge          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450             138    AZD Service Manual        when it should be off      e Internal battery pack hardware of software fault        Diag
18.  checked  In addition  since they are enumerated  it is easier to understand what the fault is     Both the EE3PSFaults and EE3LastError history can ONLY be cleared via ccShell  as they are  stored within the DM oC  The Balance Diagnostic Tool currently does not support this  functionality    The    Active Inverter State    will display any currently active DM oC faults     If history faults are displayed but no VCU DTC   s are present than there is not a current issue  with the DMoC     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 75    AZD Service Manual       Figure 30  DM oC info Codes    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 76    AZD Service Manual    7 4 VCU DTC   s    NOTE  When performing diagnostics on vehicles with multiple active DT C   s always perform  diagnostics for active Communications DT C   s first     C1000 Inertia Switch Bal 79  P0121  Throttle   Pedal Position Sensor Switch    A    Circuit Range Performance  80  P0122   Throttle Pedal Position Sensor Switch    A    Circuit LOW  sessesssssississisiisrssiesrssiniisrsnrnrssenienress 81  P0123   Throttle Pedal Position Sensor Switch    A    Circuit High  82  P0124  Throttle   Pedal Position Sensor Switch    A    Circuit lntermftent A 83  P0217 ENG  Engine Coolant Over Temperature Condition oo    ccc cccceee ee eeeeeeteneteteteieteteteeeteseeeseees 83  P0221   Throttle   Pedal Position Sensor Switch    B    Circuit Range  Performance  84 
19.  e Repair harness or connection issue        128    DESAT    There are three levels of over current protection in the DM oCs  each with the ability to act with  different response times and trip levels  The three levels are     Software Over Current   slowest response time  trip level can be adjusted by changing  software parameters    Hardware Over Current   medium response time  trip level is fixed in hardware  high trip  level       Desaturation Detection   fastest response time  trip level is fixed in hardware  highest trip                level    Description  This fault indicates that one or more of the IGBT s experienced an excessive current   This is the last level of hardware protection  triggering a critical fault which requires  power cycling the DM oC to re enable    Possible e Motor that is being driven by the DM oC has a phase to phase short    Causes  e Thecable to the motor has a phase to phase short    e Failed DM oC  Current sensor failure or disconnected  The IGBT or  other internal circuitry of the DM oC  DM oC  has catastrophically failed   e Faulty DMoC grounding              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 125    AZD Service Manual          Diagnostic  Aids     The electrical system in this vehicle is capable of producing lethal  voltage levels     All hybrid drivetrain and control systems must be maintained and  serviced by trained personnel who are qualified to service Azure  hybrid vehicle systems        e 
20.  freeze frame data and a DM oC Info Code is stored   The engine will be forced on and stay running and the Hybrid Service light will  be on solid        Possible Causes     Faulty EPAS motor Controller   Faulty EPAS M otor   Faulty Wiring        Diagnostic A ids           Refer to M otor Controller info Codes DM oC Info Codes and freeze frame  data for additional information           P1A45  Electric Power Steering Control Module       Description     The EPAS DM oC state does not match the state being commanded by the VCU   The engine will be forced on and stay running and the Hybrid Service light will  be on solid        Possible Causes     EPAS motor control was just reprogrammed to new software without the  V oltage calibration performed    Faulty EPAS motor Controller    Incorrect DM oC software        Diagnostic A ids           Compare the ESS buss voltage to the reported voltage from the EPAS  DM oC and use ccShell to recalibrate DM oC voltage   Reprogram M otor Controller with latest software from A zure       P1A46  Electric Power Steering under Speed Fault       Description     The reported EPAS speed has dropped 600 rpm below the requested set point for  greater than 1 second  The engine will be forced on and stay running and the  Hybrid Service light will be on solid        Possible Causes     Faulty EPAS M otor    Tight or seized Pump bearings   Slipping pump belt    Low fluid level or air in the PS lines       Diagnostic A ids           Remove EPAS belt and manu
21.  is a known bug that has no  negative effect   e If  Active  ESS should be replaced and A zure Techline notified                 7 6 25M isc  Contactor    Description  The CBCM has found that either the positive or negative contactor has opened  while being commanded to close   i e  Link V oltage does not match Pack  V oltage even though contactors have been closed            POSSIDIE CAUSES e Internal battery pack fault  contactor shorted or welded shut  link or pack    voltage being misread  software fault         Diagnostic A ids  e Use Balance Diagnostic tool and record all faults  e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software                    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 148    
22.  lower voltage           Possible Causes        e Inaccurate software voltage calibration allows the DC bus to go to too  high a voltage    e Other component on high voltage bus is causing a voltage spike    e Failed DM oC  Noisy signal from power board where high voltage DC  is scaled down to 0 5 volts range    e Contactor opening or fuse blowing during regen    e PM motor overspeed and back EMF voltage is too high    e Battery is over charged           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 121             AZD    Service Manual          Diagnostic A ids        Verify Battery voltage is within the recommended range    Recalibrate DM oC voltage with ccShell    Check that grounding and shielding is done properly to prevent noise   Log ISR1UsDC  ISR2EstB atCurrent  ISR 2H ertz    A loss of motor control stability at high speed might put too much  current onto the bus  particularly for permanent magnet motors   Contact  Azure Dynamics Product Support   Techline Support        7   PS_FLT_HARDWARE    oC       Description  All hardware over current faults will trigger the enumerated fault code    PS FLT HARDWARE_OC  The EE3LastError detects each fault individually        Possible Causes     Wrong or corrupt Software  calibration    Damaged motor  M otor inductance is not correct    Bad speed sensor or noisy speed sensor  Bad reading of rotor position  causes DM oC to produce voltage vectors that are incorrect and cause an  over current    Syste
23. 2    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 78    AZD Service Manual    P250A  Engine Oil Level Sensor Circuit    112  P2519  A C Request  A    ef re EE 112  P2533  Ignition Switch Run Start Position Clrouft  ccseseeeeeeetececeeeee eee ceceseeeeneeieieieneneneteteseeeees 112  U0100 ENG   Lost Communication with ECM DCH  AT  113  U010F Lost Communication With Air Conditioning Module    113  U0110  Lost Communication with Drive M otor Control Module  AT    114  U0111   Lost Communication with Battery Control Module     114  U0120 Lost Communication with Starter   Generator Control Module ANNE 115  U0121 ABS  Lost Communication with Anti Lock Brake System  ABS  Control Module    115  U0131  Lost Communication with Power Steering Control Module    116  U0151  Lost Communication with Restraint Control Module AA 116  U0155   Lost Communication with Instrument Panel Cluster  IPC  control Panel ssec 116  U0311 Software Incompatibility With Drive M otor Control Module    116  U 1030 Software Incompatibility With Air Conditioning Module  117  U 1031 Software Incompatibility With Power Steering Control Module    117  U 1032 Software Incompatibility With Starter   Generator Control Module    117  U 1300  U 1301  U 1302  U 1303  1304  U 1305  U 1306  U 1307  VCU Low Memory Margin               118  U 1310  U 1311  U 1312  U 1313  1314  U 1315  U 1316   VCU CPU uaea secere 118    C1000 Inertia Switch Tripped       Description  The Inertia switch input 
24. APP track 1  2  3 and compare    signals   Refer to appropriate A zure wiring schematics   Refer to appropriate Ford Diagnostics for APP sensor track 3 signal        P0504 Brake Switch    A        B    Correlation                   Description  VCU brake switch digital input does not correspond with CAN reported PCM  brake ON OFF  BOO   The HY BRID SERVICE light will be on solid   Possible Causes  e Wiring harness or connection problem from brake switch to VCU   e Wiring harness or connection problem from brake switch to PCM   Diagnostic A ids  e UseBDT  Balance Diagnostic Tool  on CAN 1 and monitor    Brake    ON OFF signal    Compare    Brake ON OFF signal on the BDT display with the BOO  on  FORD IDS tool    Refer to appropriate A zure wiring schematics    Refer to appropriate Ford wiring schematics           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 88             AZD    Service Manual    P0531 A C Refrigerant Pressure Sensor    A    Circuit Range Performance       Description     The Cab AC switch input to the VCU switches faster than max defined frequency    of 25 Hz  The vehicle will continue to operate normally and the Hybrid Service  light will be on solid        Possible Causes     e AC Switch circuit   intermittent connection   e Faulty AC switch  if equipped         Diagnostic A ids        e Use Balance diagnostic tool to monitor AC switch Input     Refer to appropriate A zure wiring schematics and check all electrical  connectio
25. AZD Service Manual    7 Diagnostics    7 1  7 2  7 3  7 4  7 5  7 6    Preliminary DiaghoStiCS siscscssssssississssssstesssssstsscsscsasentsssassscssnsssssssnisrssnssconssssscancessesaenies 70  Ford PCM   Hybrid VCU Interaction     ssssssssssssusunnnnnnnnnnnnnnnnnnnnnnununnnunnnnnananananananananan 72  Overview of Hybrid DIC S sssscscssssiscestssscssssesscsssarencescsssssescssassestsscsssesissnsesinsentossasastas 74  VCU DT GS E 77  DM OC Info Codes castictiitiiincitinictnninaiini en 119  ACHT Trei  129    7 1 Preliminary Diagnostics    The procedures in this section must be performed by certified technicians  who have been trained in the use and service of high voltage hybrid   electric vehicles and high voltage components     V oltage above 30 volts should be considered potentially dangerous and are  referred to as High Voltage or HV     Always wear appropriate personal safety equipment and take appropriate  precautions when working with high voltage components or wiring     Never service a component if high voltage is present        Before starting with any diagnostic procedures  always verify the complaint  Next perform a  visual inspection of the following     1     All fluid levels are within proper operating levels     Note  the PAS fluid level must be checked and or filled at a system fluid temp not less  than 10C  If circumstances arise where it does need to be filled at a temp less than 10C  then it will need re checking later at a system temp above 10C to avoid ove
26. Diagnostic A ids           Follow diagnostic by description EPAS DM oC not functioning or not  communicating    Follow diagnostic by description Loss of CAN 2 communications   Refer to appropriate A zure wiring schematics              U0151  Lost Communication with Restraint Control Module       Description     RCM CAN message is arriving too slow  or any RCM message is not being  received at all  this fault will set  The Hybrid Service light will be on solid        Possible Causes     Can terminator resistor failure CAN 1   Faulty Restraint Control M odule   Wiring or connection problems        Diagnostic A ids           Follow diagnostic by description Loss of CAN 1 communications   Refer to appropriate A zure wiring schematics   Refer to Ford diagnostic relating to restraint control module           U0155   Lost Communication with Instrument Panel Cluster  IPC  control Panel       Description     The VCU will monitor the IPC CAN messages  If any IPC message is arriving too  slow  or any message is not being received at all  this fault will set  The  HYBRID SERVICE light will be on solid        Possible Causes     Can terminator resistor failure CAN 2   Failed instrument cluster   Faulty wiring or connection problems        Diagnostic A ids           Refer to appropriate A zure wiring schematics   Refer to pinpoint test procedure Loss of CAN 2 communications   Refer to Ford diagnostics for IPC           U0311 Software Incompatibility With Drive Motor Control Module         
27. Disconnect motor cables and measure the resistance between each  phase and ground  The resistance should be greater than 1 0 M egaOhm    e Perform Isolation Resistance test Isolation Resistance T esting   e Disconnect motor cables and safely isolate them from both the motor and  the phase windings   For ISG or TM   Restart the vehicle in hybrid mode and attempt to move  the vehicle forward in forward or reverse  If faultisonaEPAS DM 0C   Using the BDT  enable diagnostic mode and then enable high voltage  mode  M anually engage EPAS system  If fault reappears  replace DM oC                  129   PS_FLT_CURRENT_CALIB_FAULT          Description  The DM oC has detected an internal hardware failure  current calibration outside  of allowed bounds  indicating a possible problem with the current sensors   Possible Causes  Offset calibration out of range due to extreme cold temperatures  below      20  C on some hardware      Failed DM oC  Current sensor failure or disconnect  internal failure            Diagnostic A ids  e Verify temperature is not extremely cold    e UseccShell scope tool to log currents and voltages  at 10kHz logging  rate log the following  ISR2IdF  ISR2IqF  ISR1IsV  and ISR1IsW  send  the captured data to A zure for analysis    e If the above test okay  replace the DM oC              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 126    AZD    Service Manual     an  PS_FLT_EXTERNAL_PS DISABLE_AT ENABLED       Description     This fa
28. EE2N egOverspeed in the reverse direction        Possible Causes     Over speed of the M otor  Noisy speed sensor signal  Failed speed sensor connection issue           Diagnostic Aids        Confirm the shutdown sequence for the DM oC was correct  with all  torque request being zeroed at least EE 2PSIdleT ime before the HV  dropped below EE2PSOffBat    e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software           12   PS_FLT_SVPWM_ERROR       Description     This results from calibration settings which reference an unsupported operating  mode    Note  This  fault  cannot be cleared so it is really more like a critical fault   Contact A zure for details       Possible Causes     e Incorrect Software          Diagnostic Aids        e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software  e Contact  Azure Dynamics Product Support   Techline Support            13   PS_FLT_SPEED SENSOR ERROR          Description        Speed discontinuity which exceeds the calibratable threshold          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450                124    AZD Service Manual       EE 2SpeedD eltaF aultT hr              Possible Causes  e Speed Sensor Noise or Disconnect   e Speed sensor harness or connector connectivity   Diagnostic Aids  e LogISR2Hertz and or ISR1FluxPosition and ISR 1M Position          
29. Fault   e isolation failure in EPAS M otor or EPAS M otor controller   e Isolation failure in ISG M otor or ISG M otor Controller   e isolation failure in Traction M otor or Traction M otor Controller  e High Voltage cabling Isolation failure   e Isolation failure in DC DC converter   e Isolation failurein AC M otor or Controller       Diagnostic Aids  e Confirm ESS service disconnect pin is installed   e Use Balance Diagnostic tool and record all faults   e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software   e Turn key on  high voltage off  contactors open   and read pack   s  reported isolation resistance value  If less than 2000 kohms  pack has  internal isolation fault  replace pack        e Turn key on  high voltage on  contactors closed   and monitor the  reported isolation resistance value for 10 minutes and if less than 1000  kohms  high voltage buss has a isolation fault  R efer to Isolation  Resistance T esting                   Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 136    AZD Service Manual    7 6 6 ESS MISC  Invalid DBS State       Description  The CBCM has entered an invalid state        e e Internal battery pack software fault        Diagnostic Aids  e Use Balance Diagnostic tool and record all faults    e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software                
30. Fault input   e Refer to the appropriate Ford Wiring schematics           P1A5B  Charge Lamp Circuit High       Description     The VCU has detected that Engine Alternator Fault input signal to the VCU has  a short Circuit to battery power or short circuit to VREF  5 volt     The input  voltage is has exceeded 4 98 volt        Possible Causes     e Wiring short circuit to power   e Wiring short circuit to VSENS power   e Open circuit in the wiring           Diagnostic Aids        e Refer to appropriate A zure wiring schematics and check all electrical  connections related to Engine Alternator Fault input   e Refer to the appropriate Ford Wiring schematics           P1A5C  Inclinometer Fault          Description        The VCU has detected that the Inclinometer value fails to change value over 5  km distance  The engine will remain on and the Hybrid Service light be on  solid              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 106          AZD Service Manual       Possible Causes  e Failed inclinometer           Diagnostic A ids  e Refer to appropriate A zure wiring schematics and check all electrical  connections related Inclinometer input   e UseBDT to confirm inclinometer operation             Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 107    AZD    Service Manual    P1A70 A C Inverter Over Temperature       Description     The Air Conditioning EPAS DM oC temperature has exceeded 75  C  The  Hybrid Serv
31. Hybrid electric Vehicle   2008  2009  2010 Ford E 450 108          AZD    Service Manual          Possible Causes     e Faulty A C DMoC   e Faulty A C M otor   e Faulty Wiring           Diagnostic Aids        e Refer to DMoC info Codes DM oC Info Codes and freeze frame data for  additional information              P1A75 A C Control Module       Description     The A C DM oC state does not match the state being commanded by the VCU   The A C will be disabled and the Hybrid Service light be on solid        Possible Causes     e A C DMOC was just reprogrammed to new software without the  V oltage calibration performed    e Faulty A C DMoC    e Incorrect DM oC software           Diagnostic Aids        e Compare the ESS buss voltage to the reported voltage from the EPAS  DM oC and use ccShell to recalibrate DM oC voltage    e Verify Software level and Reprogram DM oC with the latest software  from Azure if necessary           P2109   Throttle Pedal Position Sensor    A    Minimum Stop Performance       Description     M Y 2008  The accelerator pedal track 1 signal is below 9   If no faults are  present on tracks 2  amp  3 then the vehicle will continue to operate normally and the  Hybrid Service light be on solid    If faults are present for track 2  track 3 or both as well as the P02109  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will Flash   Note  APP track 1 is an inverted signal when compared to tracks 2  amp  3 
32. Manual             Check cooling system pumps and fans    Check for kinks or obstructions in the coolant hoses   Check for air trapped in coolant system        7 6 20C ritical  Over Temperature       Description     At least battery module temperature is greater than or   75  C   Critical fault  contactors will open after 2 minutes        Possible Causes     Coolant level and temperature   Failed cooling system pumps and fans   K inks or obstructions in the coolant hoses  air trapped in coolant  system   M ultiple internal battery pack module temperature sensor or wiring  failures  Replace pack    Internal battery pack thermal failure  Replace pack        Diagnostic Aids           Check coolant level and temperature    Check cooling system pumps and fans    Check for kinks or obstructions in the coolant hoses   Check for air trapped in coolant system        7 6 21M odule  Module Sense L el       Description     This indicates the loss of 1 of the 4 battery module temperature sensors in the    pack        Possible Causes           One of the four module temperature sensors in the battery pack has  failed  the secondary sensor is being used to report module  temperatures    One of the four module temperature sensors in the battery pack has  failed  the secondary sensor is being used to report module  temperatures           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    146             AZD Service Manual    Diagnostic A ids  e Replace ESS        
33. NEENEANEAAEANANEANEANENEENEANENNENN ENEAK EEREN EEE 139  7 6 13 Module  Under Voltage prsesia e a E   139  7 6 14 Module  Over Voltage sinisiin a aaa 140  7 6 15 Module  Delta Voltage ciena aa a ta iaai a 141  7 6 16 Critical Delta Voltage A 143  7 6 17 Module  H eg CET 144  7 6 18 Module   Delta Temperature    EEN 145  7 6 19 Critical Over Ti emperdture    dccvavict mses ia EEN 145  7 6 20 Critical  Over Temperature    146    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 129    AZD Service Manual    7 6 21 Module Module Sense L V1 NENNEN 146  7 6 22 Module  M odule Sense Lev esge  eedegeseggetereiiergr eat deeger pa tataladacenpetieinasaceiecavealsataniatnets 147  7 6 23 Critical  State of Charge IG     147  7 6 24 Criti  al Ciontrol Parameter ET 148  7 6 25 E ele 148    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 130    AZD Service Manual    7 6 1 ESS  INPUT  PILOT       Description     a  TheESS measured    Pilot    voltage  external 12 volt ignition  supply for the pack   s contactors   on pin    U    of the pack   s 31  position low voltage connector  has dropped below 7 5 volts  while the ignition is ON     b  NOTE  If the Pilot Fault has been triggered  the CBCM can no  longer guarantee the operation of the battery pack contactors  If  the contactors are open when this fault occurs  the CBCM will  prevent any precharge attempts  If the contactors are closed  when the fault occurs  the contactors may open o
34. OC_FAULT_CAUSE_NO_DMOCQUIZ_CAN  DMOC_FAULT_CAUSE_CAN_OVERFLOW  DMOC FAULT CAUSE UNKNOWN CAN FAULT  DMOC_FAULT_CAUSE_UNKNOWN_SW_FAULT  DMOC FAULT CAUSE CAN BUS ERROR    DMOC_FAULT_CAUSE_IS_NOT_ ASSIGNED       VD ON DUM SS DO M   ka    NON CRITICAL FAULTS       CRITICAL       Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 119    AZD Service Manual    Enumerated Fault Codes  EE 3PSF aulto        New code  since November 2007  also includes an enumerated error  the ISR 2PSA ctiveE rror   which will display the worst case error that occurred in a human readable form  The fault history  EE3PSFault0  EE3PSFault1  etc provides the enumerated history for the last 4 faults  These error  codes were released for external use on P1 in November 2007  so the following codes are fixed   Additional codes may be added as the fault handling improves  below from ctl_pub h       0   PS_FLT_NO FAULTS    This is the desired state  NO_FAULTS  0  indicates that no fault condition is active  Or in the  error history  means no fault has occurred since the error history was cleared      1    PS_FLT_UNKNOWN_FAULT    This fault should never occur in production code  This indicates that the powerstage state  machine detected that the PWM outputs were disabled  but no known cause could be attributed   Usually this results during code development  when new fault handling has not been  implemented completely correctly  All instances of this fault should be treated seriously and  
35. Refer to wiring schematics        P1A33 AUX   Alternator   DC DC System Performance       Description  Fault monitoring begins after the system has been started in hybrid mode  Fault is  set if the engine is on  the dc dc is enabled and the 12 volt battery voltage drops  below 11 5 volts for 15 seconds with the radiator fans off or below 11 0 volts with  the Radiator fans running  The hybrid service light will be on solid                 Possible Causes  e DC DC failure   e Alternator failure   e Blown fuse or faulty wiring   Diagnostic Aids  e Using Balance Diagnostic Tool monitor input variable    12 volt Battery    Voltage    when the system is running in hybrid mode with the engine off   Refer to Alternator and DC DC System Performance   Refer to appropriate wiring Schematics           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 102          AZD Service Manual    P1A40  Electric Power Steering Inverter Over Temperature          Description  The EPAS DM oC temperature has exceeded 75  C  The instrument Cluster  temperature gauge will read    H    or inthe RED  The EPAS shroud fan will be on   Possible Causes  e Faulty EPAS DM ot     e Blockage of air flow to cooling fins   e Faulty EPAS DM ot fan operation        Diagnostic Aids  e Visually inspect traction motor Controller cooling fins  plenum fan  shroud for blockages   e Refer to Azure wiring Schematic                 P1A41   Electric power Steering Motor Stator Over Temperature       De
36. Repair as required   If no  replace the Inclinometer    Refer to appropriate A zure wiring schematics and check all electrical  connections related to Inclinometer        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 105          AZD    Service Manual    P1A58 Inclimometer Circuit High       Description     The VCU has detected that Inclinometer analog input signal to the VCU has short  Circuit to battery power or short circuit to VREF  5 volt    or an open Circuit   The Inclinometer analog input voltage to the VCU is greater than 4 8 volts to set  this fault    The engine will always stay running and the Hybrid Service light be on solid        Possible Causes     Faulty Inclinometer    Wiring short circuit to power    Wiring short circuit to VSENS power   Open circuit in the wiring        Diagnostic A ids        Check for open circuit to Inclinometer    e Refer to appropriate A zure wiring schematics and check all electrical  connections related to Inclinometer    e Refer to Diagnostic by Description Inclinometer does not read correctly             P1A5A  Charge Lamp Circuit low       Description     The VCU has detected that Engine Alternator Fault input signal to the VCU has a  short Circuit to Ground  The input voltage is less than 0 1 volt        Possible Causes     Wiring short circuit to ground        Diagnostic A ids        e Refer to appropriate A zure wiring schematics and check all electrical  connections related to Engine Alternator 
37. S     ESS Diagnostics    There are two controller hardware revision levels in the NiMH battery pack  the newer Algonia  and older CBCM type controllers  Unfortunately the stored fault definitions conflict on two  faults  The BDT accommodates the conflict by displaying both codes  and the diagnosis will  need to proceed based on the controller type  The codes displayed for these two faults are as  follows    e Input  DBS  CBCM  or Service Disconnect  A lagonia     e Input  Default Param Loaded  CBCM  or DBS  Alagonia     Note No ESS DTC  P1A 20  is flagged by the V CU when the only active ESS fault reported by  the pack is a failed CBCM  Alagonia HW  however  the CBCM  Alagonia HW Failed fault will  be recorded in the ESS fault buffer  This DTC has been disabled by the VCU due to frequent  invalid reporting of the fault by the ESS     7 6 CT Taube  TN 129  TOL ESS   INPUT  PILOT meeste deninedautarianintig Avoidant ae unianindesanaaaies 131  T62   ESS   Input Pack UD nunn aa a a a a G 132  76 3 ESS   Input  CAN II  134  POA ESS    Nout A 2D Paul tess nti eidele aaa Ea aE 135  7 65 ESS   Input  DBS Faults est AER  136  7 60 62  ESS M SC  Invalid  DBS Stettin iererereg eegene a Ree 137  7 6 7 Misc  Invalid Pack State    137  LED Misc  Invalid Precharge State airin usnisa inania a naaar h anisa aiia 137  7 6 9 Input  Default Param Loadel AAA 137  7 6 10 Precharge  Positive Relay Short    138  7 6 11 Precharge  System Short    138  7 6 12 Precharge  T Imeout tnnt A uN EKAAANENAENN
38. Tool  check the    Yes  Clear faults and recheck           Pilot Voltage   refer to illustration  No  Go to step 5  Analog Input Voltages  Pin Number  Controller12V Voltage  13 4   a  Key in Voltage    13 8   L  Pilot Voltage   139V U  Pack ID Voltage  13 9   N  Is battery voltage higher than 7 5 volts   5 Check Power to the Battery Pack   Yes  e Key OFF  connector C0535 disconnected from   GO to step 6  the battery pack  N  0    e KeyON  measure the voltage from pin U  12  volt power  to pin Z  ground     Is battery voltage present     Refer to the proper wiring diagram and repair fault     Check inertia switch       6 Check Connector          e Key OFF  connector C053S disconnected   e Check for loose or pushed pins at both sides of  the connector    e Confirm that the ESS access panel lid is  securely fastened     Are any issues found       Yes  Repair as required     No  Replace battery pack       7 6 2 ESS   Input  Pack ID          Description        The Pack Identifier Signal was measured and found to be invalid  This condition  is checked just once after the CBCM wakes up  If the Pack Identifier signal is  lost after the CBCM initialization sequence is complete  it will not be noticed           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    132          AZD    Service Manual       Fault will be set as well     NOTE  If the Pack Identifier Fault is set  it is likely that the CAN Link Lost       Possible Causes   key ON     e 12 volt batt
39. V N    Is battery voltage higher than 7 5 volts        5 Check Power to the Battery Pack        e Key OFF  connector C053S disconnected from  the battery pack    e KeyON  measure the voltage from pin U  12  volt power  to pin Z  ground     Is battery voltage present   NOTE  this circuit is fed from the fuse panel and is live  at all times     Yes  Go to step 6    No  Refer to the proper wiring diagram and repair fault   Check inertia switch       6 Check Connector       e Check both sides of the connector for loose or  pushed pins  corrosion  or other electrical faults    Are any issues found          Yes  Repair as required     No  Replace battery pack          7 6 3 ESS   Input  CAN  21A          e Failed VCU          Description   The CBCM has not received a properly formatted  21A message within the  timeout period  2000ms    NOTE  If this fault occurs and the pack was connected  contactors  closed  then the pack will stay connected   Possible Causes  e Electrical Noise on CAN 2    e CAN 2 terminator resistor failure    e Faulty power and ground circuits to ESS  e Faulty wiring or connection problems          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    134       AZD Service Manual    Diagnostic Aids  e Use the Balance Diagnostic tool and confirm the latest ESS software  has been loaded  Refer to https    extranet azuredynamics com for the  latest software   e Confirm VCU communications with Balance Diagnostic tool   e Follow diagnostic 
40. ZD    Service Manual             Sensor range is  40   C to 85  C  87   C  sensor failure        7 6 18M odule   Delta Temperature       Description  The  maximum module temperature   minimum module temperature  is greater  than or   15  C and remains in this condition for 5 sec                 Possible Causes  e Check coolant level and temperature   e Check cooling system pumps and fans   e Check for kinks or obstructions in the coolant hoses   e Check for air trapped in coolant system    Diagnostic Aids  e Use Balance Diagnostic tool to monitor readings    If all sensors read close to the same readings then check for a coolant  issue  If only one sensor reads high   then replace ESS    Sensor range is  40  C to 85  C  87  C  sensor failure        7 6 19C ritical  Over Temperature       Description  At least one of the modules is greater than65  C for greater than 5 sec    Note  Typical temperature change from coolant to max module  temperature shouldn   t exceed 20  C        Possible Causes     Coolant level and temperature   Failed cooling system pumps and fans   K inks or obstructions in the coolant hoses  air trapped in coolant  system   M ultiple internal battery pack module temperature sensor or wiring  failures  Replace pack    Internal battery pack thermal failure  Replace pack        Diagnostic Aids  e          Check coolant level and temperature           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450             145    AZD    Service 
41. ally spin EPAS pump  If pump is hard to  turn by hand  replace pump    Check belt tension    For intermittent faults  turn the steering wheel to full lock and hold to see  if fault re appears        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 104             AZD    Service Manual    P1A47  Electric Power Steering Position Sensor Fault       Description     The reported EPAS speed is less than 300 rpm and the then torques reported by  the EPAS motor Controller is greater than 13 NM  The engine will be forced on  and stay running and the HY BRID SERV CIE light will be on solid        Possible Causes     Faulty EPAS Motor  speed senor   Tight or seized Pump bearings        Diagnostic A ids           Remove EPAS belt and manually spin EPAS pump  If pump is hard to  turn by hand  replace pump   Check belt tension        P1A57 Inclimometer Circuit low       Description     The VCU has detected that Inclinometer analog input signal to the VCU has a  short Circuit to Ground  The Inclinometer output voltage is less than  2 volts   The engine will always stay running and the Hybrid Service light be on solid        Possible Causes     Failed Inclinometer   Wiring short circuit to ground        Diagnostic A ids           Unplug Inclinometer and clear fault with Balance diagnostic tool  Start  the vehicle and see if the fault reappears    Note  An unplugged sensor should cause a P1A 58  If the P1A57  reappears then there is a short circuit in the harness  
42. any  message is not being received at all  this fault will set  The Body Air  conditioning will be disabled and The HY BRID SERVICE light will be on       solid   Possible Causes  e CAN terminator resistor failure CAN 2   e Faulty A C DMoC   e Failed 12 volt power or grounds toA C DMoC   e Wiring or connection problems           Diagnostic A ids  Use BDT  Balance Diagnostic Tool  to check A C function   e Refer Azure wiring schematic    e Refer to pinpoint test procedure Loss of CAN 2 communications                 Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 113    AZD Service Manual    U0110  Lost Communication with Drive Motor Control Module    A          Description  If any Traction M otor DMoC CAN message is arriving too slow  or any message  is not being received at all  this fault will set  The vehicle will be set to a    Forced  Conventional M ode    and The HY BRID SERVICE light will be on solid        Possible Causes        e CAN terminator resistor failure CAN 2   e Faulty traction DM oC   e Failed 12 volt power or grounds to ISG DM oC   e Wiring or connection problems   Diagnostic A ids  e Follow diagnostic by description Traction DM oC not functioning or not       communicating   e Follow diagnostic by description Loss of CAN 2 communications     e Refer to appropriate A zure wiring schematics                    U0111   Lost Communication with Battery Control Module    A          Description  Fault monitoring begins 1 second after 
43. attery Precharge Contactor CIrCult cc cccceeetsteteteteceeeeeeeseeeceseeeeiesieieieneneeeteneteteees 95  POC2F ENG   Internal Control Module Drive M otor G enerator Engine Speed Sensor Performance      95  P0C76 Hybrid Battery System Discharge Time too Jong    96    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 77    AZD Service Manual    P1A 00 Drive motor A  Critical is e ENEE 96  PIAOL Drive Motor    A    Inverter Faults siririna aaia 96  P1A 02   Drive M otor    A    Stator Over Temperature     cccccceeeceeeetenetenetensesceeesseieisisieteneneeeteteeesites 97  P1A 04  Drive M otor    A    Position  Sensor Transmission Output Speed Sensor Correlation 0    97  P1A 10  Generator Inverter Critical Faute 98  PIATI Generator  Inverter Faults iraniana a NEEN 98  P1A 12   Generator Stator Over Temperature     s sssssssssrssrsrssrnrunnnsstnnnurnuunenuuennnurnnonnnnuununurnuenenuuunuenrnuonenann 99  P1A 20 Battery Control Moduletailt NENNEN 99  P1A21 Battery Control Module Critical Fault  ccc ccc eeeeenenenenensescececeesssisieieieteneneteteeeteses 100  P1A 22   System Isolation Fault W amimg  innnan en an 100  P1A30  Hybrid Voltage M easurement Correlation    ssessssissssiesisisiissesinsisenrisisnininnnnieninniniininnnns 101  P1A 31 Starter Performance AAA 101  P1A32  Hybrid Control Module Command Engine Pedal Correlation    ccsercrrrreeees 102  P1A33 AUX   Alternator   DC DC System Performance AAA 102  P1A 40  Electric Power Steering Inverter Over T
44. by description Loss of CAN 2 communications   Refer to appropriate A zure wiring schematics                         7 6 4 ESS   Input  A2D Fault    Description  The CBCM has lost communication with its on board external A 2D chip or the  power on calibration of the current sensor has failed           Possible Causes  e Internal battery pack fault       Diagnostic Aids  e Use Balance Diagnostic tool and record all faults  e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software                   Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 135    AZD Service Manual    7 6 5 ESS   Input  DBS Fault    Description  The high voltage battery pack is electrically isolated from the vehicle chassis  It  monitors the system to detect any faults that would allow a high voltage  connection to the vehicle chassis  This fault indicates that the ESS has detected  a ground fault that would allow current flow to the chassis  If the ground fault  isn   t internal to the pack  it could mean there is a ground fault elsewhere on the  HV buss     This fault could also mean that the pack was keyed on with the service  disconnect pin not installed as the isolation resistance can   t be properly  measured with the service disconnect pin out  With the key on and the   disconnect pin out  it will read 0 kohms           Possible Causes  e ESS Service disconnect Pin is removed   e Internal ESS ground 
45. conventional mode jumper wire  and jumper pins  30 and 87a on relays K12 and K8  Clear fault codes and retest in conventional mode  If faults  are still present  follow Ford diagnostic procedures with the inclusion of the A zure transmission  control wiring and repair as necessary  If faults do not reappear  refer to A zure wiring  schematics and repair wiring or relays as required  Refer to wiring diagrams     7 2 3 Ford APP Faults    The VCU controls the APP signal by sending outa PWM signal to the PAC  PWM to Analog  Controller  and the PAC in turn sends out an Analog signal to the PCM APP inputs  For any  APP related faults please check for VCU faults first and verify PAC operation  Use Balance  Diagnostic tool to manual control APP inputs and use the Ford IDS tool to monitor A PP inputs   If the inputs and outputs do not match refer to A zure wiring diagrams and repair as required     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 72    AZD Service Manual    PWM 1 PWM to Analog 1 Engine  WS Analog PCM                 Accelerator    Analog 1           Analog 2       Analog 3          Ener  Driver     gt  M eier  gt  Signal  gt  Engine  Demand Algorithms Converter Controller    7 2 4 Instrument Cluster    The VCU acts as a gateway between the instrument cluster and any Ford installed control  modules including RCM and ABS  Any loss of instrument cluster functionality or intermittent  instrument cluster displays should be verified with the Bala
46. diagnosed so that proper fault reporting can be implemented      2   PS_FLT_ERROR_ON ENABLE       Description  This fault is flagged if after enabling the gate drivers  a fault is immediately  detected        Possible Causes  e Problem with fault clearing circuit   e Fault active while trying to enable  Hardware overvoltage might cause  this             Diagnostic Aids  e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software  If fault  persists  replace controller               3    PS_FLT_RELAY_ERROR AT_READY   4    PS_FLT_RELAY_ ERROR AT_ENABLED    These faults are very similar  indicating that the contactor was detected to be open when it was  commanded closed  These faults only distinguish if the DM oC was switching  enabled  at the  time the fault was detected     This hardware configuration is controlled by parameter change  EE ZC ontactorlsInternal will  default to TRUE  1  for most applications  If your DM oC does not have an internal contactor   this parameter should be set to FALSE  0   Follow the appropriate diagnostics path below     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 120       AZD    Service Manual       Description     Contactor state is not closed when powerstage state is READY or ENABLED        Possible Causes     Blown Fuse internal to DM oC   Calibration error  check that your unit is calibrated for an external contactor    Shielding grounding pr
47. e faults and contact   Email saved DTC   s to techline  azuredynamics com       If faults frequently reappear or are continually active contact  e Product Support   Techline Support   Toll Free Number  1 866 473 1636   Phone  905 607 3486                Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 118    AZD Service Manual    7 5 DMOC Info Codes    When a fault occurs on the DM oC it is logged into a short  4 fault  error history that is read with  the BDT under the DTC   s  Info codes under EE3PSFault0  1  2 or 3     A VCU DTC will also be set with any DM 0C   s info code and the specific DM oC info code is  captured in the Freeze Frame Data under ISG  TM  AC  or EPAS     The table below shows both critical and non critical faults related to the DM 0C   s   Note  All DMoC   s  EPAS  ISG  AC and TM   report the same info codes     DMOC INFO CODES    PS FLT NO FAULTS  PS FLT UNKNOWN FAULT   PS FLT ERROR ON ENABLE   PS FLT RELAY ERROR AT READY   PS FLT RELAY ERROR AT ENABLED   PS FLT CHARGED ERROR   PS FLT HARDWARE OV   PS FLT HARDWARE OC   PS FLT SOFTWARE OC   PS FLT SOFTWARE OV   PS FLT DC BUS UNDER VOLTAGE   PS FLT OVERSPEED   PS FLT SVPWM ERROR   PS FLT SPEED SENSOR ERROR   PS FLT DESAT   PS FLT CURRENT CALIB FAULT   PS FLT EXTERNAL PS DISABLE AT ENABLED  PS FLT KERNAL DISPATCHER ERROR   PS FLT UNDEFINED CASE ERROR  DMOC_FAULT_CAUSE_PS_OFF  DMOC_FAULT_CAUSE_NO_COMMAND1_CAN  DMOC_FAULT_CAUSE_NO_COMMAND2_CAN  DMOC_FAULT_CAUSE_NO_VCUQUIZ_CAN  DM
48. e in DC DC converter    Isolation failure in AC M otor or Controller        Diagnostic A ids           Refer to Isolation Resistance T esting   Refer to ESS Info Codes ESS   Input  DBS Fault              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 94          AZD Service Manual    POAE1 Hybrid Battery Precharge Contactor Circuit          Description  ESS reports a precharge state of  Precharge failed    The vehicle will be set to     Forced Conventional mode    and the HY BRID SERVICE light will be on solid   Possible Causes  e ESS failure     e Short or unintended load on the high voltage B uss at time of precharge        Diagnostic A ids  e Using Balance Diagnostic tool check for any ESS Info codes  repair as  required    e Isolate the Battery from the other HV components and attempt to start  vehicle  using the Balance Diagnostic tool monitor the Precharge state  and determine if the precharge Fail is still active  if yes  replace ESS if  No  perform individual component testing of each HV component and  look for a short in a component or wiring    e Refer to appropriate A zure wiring schematics                 POC2F ENG   Internal Control Module Drive Motor Generator Engine Speed Sensor    Performance       Description  The reported ISG speed differs from 2 5 x the reported engine speed by     1000rpm for more than 5 seconds    The hybrid system will set to Forced Conventional mode and the hybrid service  light will be on solid        Poss
49. electric Vehicle   2008  2009  2010 Ford E 450    122             AZD    Service Manual             https   extranet azuredynamics com for the latest software  e Check the value of EE1SoftOCLimit is zero or negative   e Contact  Azure Dynamics Product Support   Techline Support           9   ba FLT_SOFTWARE_O volts       Description     The software O volts fault is flagged when software detects an overvoltage  condition  The threshold for this error detection is set by parameter calibration   In case of a Hardware OV  this fault may be triggered simultaneously  Triggered  when the filtered DC V oltage exceeds the calibrated value of   EE1M axSwitchingV dc        Possible Causes     e Inaccurate software voltage calibration allows the DC bus to go to too  high a voltage    e Other component on high voltage bus is causing a voltage spike    Failed DM oC  Noisy signal from power board where high voltage DC   is scaled down to 0 5 volts range    Contactor opening or fuse blowing during regen    PM motor over speed and back EM F voltage is too high    Battery is over charged           Diagnostic A ids        Verify Battery voltage is within the recommended range    Recalibrate DM oC voltage with ccShell    Check that grounding and shielding is done properly to prevent noise   Log ISR1UsDC  ISR2EstB atCurrent  ISR 2H ertz    A loss of motor control stability at high speed might put too much  current onto the bus  particularly for permanent magnet motors    e Contact Azure Dynamics
50. emperature AAA 103  P1A 41   Electric power Steering Motor Stator Over Temperature  103  P1A 43  Electric Power Steering Inverter Critical Fault cccccceseseneteeeeecceeeseieeieieneneneneteeesetes 103  P1A 44  Electric power Steering Inverter Faul    104  P1A 45  Electric Power Steering Control Module    104  P1A 46  Electric Power Steering under Speed Fault AA 104  P1A 47  Electric Power Steering Position Sensor EFault cccccceceeetetetensescecceseeisieieieteeeteteteeeeeees 105  PIA57 Inclimometer  Circuit low ET 105  P1A58 Inclimometer Circuit High    NENNEN 106  PLASA  Charge Lamp Circuit le 106  PIA5B  Charge Lamp Circuit High  106  PIASCHIinclinometer RUE 106  P1A70 A C Inverter Over Temperature    ceeeeseesecensteeseeeeceetsneeseeeeseeeeeatneeceeseenasaneeseneenatantesenatas 108  P1A71 A C M otor Stator Over Temperature  108  P1A73 A C Inverter Critical Eat  108  PIA 74  A C Inverter Fault inira tated Miva abve doa hatin andi adden shiva tiadbeds 108  PIA 75 A C Control Module  siisii aa 109  P2109   Throttle Pedal Position Sensor    A    Minimum Stop Performance   scssererererrns 109  P2113   Throttle Pedal Position Sensor    B    Minimum Stop Performance    110  P2114   Throttle Pedal Position Sensor    C    Minimum Stop Performance    110  P2163  Throttle   Pedal Position Sensor    A    M aximum Stop Reriormance 111  P2164  Throttle   Pedal Position Sensor    B    Maximum Stop Performance  111  P2165  Throttle   Pedal Position Sensor    C    Maximum Stop Bertomance  11
51. equests an acceleration torque     7 3 Overview of Hybrid DTC   s   7 3 1 Vehicle Control Unit  VCU    The hybrid system is made up of several components  Each component has its own fault  reporting  The VCU monitors these components via CAN communications and depending on    the severity of the fault condition will seta DTC   Diagnostic Trouble Code  and will illuminate  the    HY BRID SERVICE    LED     There are two types of V CU faults   1  Active Vehicle DTCs  the fault is currently in fault mode     2  Stored Vehicle DT Cs  The fault has been active at some point in the past     e Upto 16 Faults are stored in the fault buffer along with freeze frame data until  they are cleared with the diagnostic tool     Diagnostic Disabling    If the 12V battery voltage falls below 9 5V  all diagnostics are disabled  After 1s  to allow for  momentary voltage drops during 12V starter cranks   low voltage diagnostics for the PCM and  the ESS are re enabled as these components are able to operate below the 9 5V threshold  All  other diagnostics will remain disabled until the battery voltage is greater than or equal to 10V     Diagnostic M ode    All diagnostics are disabled when the vehicle is in diagnostic mode  Diagnostic mode can only  be entered using the BDT   Balance Diagnostic Tool  when the vehicle is in K ey on   but not  start or run    This mode allows for manual control of the various output controls from the V CU  and allows for module reprogramming     7 3 2 ESS  Energy St
52. ervice Manual       This code indicates that the system has detected a Delta V oltage sufficiently  high to cause a critical fault  Once the critical fault has been set  the system will  limit the power to 0 kW and the contactors will open after 2 minutes  Once the  critical fault has been set  the system has to be powered down before the  contactors can reset        Possible Causes     e Pack modules are weak or poorly balanced  Replace pack   e Pack is cold  below 0  C      e Internal battery pack fault  module voltages are being misread due to  hard or software fault   Replace pack        Diagnostic Aids           e UseBDT to monitor pack Minimum and M aximum module voltages  modules  If the SOC is greater than 45   amp  the voltage delta is greater  than 2 volts replace the ESS        Module Voltages    Maximum Module    147W  Minimum Module    14 5    Figure 31    7 6 17 M odule  Over Temperature       Description     At least one of the module temperatures in the battery pack is greater than or    65  C and remains in this condition for 5 sec        Possible Causes     e Faulty ESS temperature Sensor  e Low orno coolant  e Blocked or kinked coolant hose        Diagnostic Aids           e Use Balance Diagnostic tool to monitor readings   e If all sensors read close to the same readings then check for a coolant  issue   e  f only one sensor reads high   then replace ESS          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450          144    A
53. ery voltage is low  below 7 5V    e Open  intermittent  or corroded 12 volt battery connection to pin    N     at                      Diagnostic A ids  e See pinpoint test below  Test step Result   Action  1 Perform preliminary diagnostics   Yes  Repair and retest   No  Were any issues found  Go to step 2  2 Check the Battery Software Yes  e KeyON  do not go to the high volt mode  Go to step 3  e Using the Balance Diagnostic Tool   check the  software version No    Is the latest version of software loaded     Refer to https    extranet azuredynamics com  for the latest software     Load latest software and retest        3 Clear Codes       e KeyON  but do not start the vehicle    e Using the Balance Diagnostic tool  clear all  battery codes    e Cycle the key OFF and then back ON and  restart the vehicle    e Check for codes     Does the Input  Pack ID Fault return     Yes  Go to step 4    No  No fault found       4 Check Power to the Battery Pack           e Key OFF  connector C053S reconnected    e Key ON  do not go to the high volt mode    e Using the Balance Diagnostic Tool  check the  Pilot Voltage   refer to illustration        Yes  Clear faults and recheck     No  Go to step 5          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    133    AZD Service Manual       Test step    Result   Action       Analog Input Voltages   Pin Number  Controller12V Voltage    1344 a  Key in Voltage   138V L  Pilot Voltage   139V U  Pack ID Voltage    138
54. faults and retest  the battery pack   e Check for active and historic faults  No    Go to step 3          Areany critical SOC faults present     Note  Delta voltage faults are easily set if the  SOC is ata critical point  Fix SOC faults  before proceeding with this or any other faults        3 Check M odule V oltages       e Key ON  using the Azure Battery Diagnostic Yes  software  check the minimum and maximum Replace the pack  module voltages   NOTE  Only proceed if the SOC is greater than   No  40  and the pack has not undergone recent Go to step 4  heavy charge  discharge    e Pack voltage divided by 28   the average  module voltage    e Subtract the minimum module voltage from the  average voltage   e Subtract the average module voltage from the  maximum module voltage           Are the results of the first greater than 2 5  volts or the second greater than 1 2 volts     N ote  this would indicate weak modules   Under resting conditions  the module voltages  should be within 0 2 volts minimum to  maximum        4 Attempt to go to the High Volt Mode           e Key ON  Using the Azure Battery Diagnostic Yes  software  clear the battery faults  Go to step 5  e Attempt to go to the high volt mode           No  Replace the pack          Is battery voltage higher than 7 5 volts        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 142    AZD    Service Manual       Test step    Result   Action          5 Monitor M odule V oltages        e Key ON 
55. he electric radiator  cooling fans will be on   Engine On Only    Possible Causes  e Base vehicle issue  thermostat or mechanical engine failure    Low coolant level             e  e Radiator Blockage  e Radiator fan failure  e Fan control or wiring  Diagnostic A ids  e Using Balance Diagnostic Tool  verify manual fan control  if fans operate    normally then follow ford E450 2008 diagnostic procedures else refer to  appropriate wiring schematics     e Refer to Temperature gauge reads    H    overheating for fan on off  temperatures                 83    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450       AZD    Service Manual    P0221   Throttle   Pedal Position Sensor Switch    B    Circuit Range  Performance       Description     MY 2008  The accelerator pedal tracks 1  amp  2 and 2  amp  3 are different by more than  5   If no faults are present on tracks 1  amp  3 then the vehicle will continue to  operate normally and the Hybrid Service light will be on solid    If faults are present for track 1  track 3 or both as well as the P0221  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash     MY 2009  The accelerator pedal tracks 1  amp  2 are different by more than 5   The  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash        Possible Causes     e APP track 2 connectivity   e APP sensor fault        Diagnostic A ids 
56. high  voltage reading is greater than 30 volts  The vehicle will be set to    Forced  Conventional mode    and the HY BRID SERVICE light will be on solid        Possible Causes  e Wiring or connection problem    e Improper V oltage calibration on one of the DM oCs   e Motor controller or ESS internal failure    e Blown high voltage fuse in junction box or ESS        Diagnostic Aids  e Use Balance Diagnostic tool to compare voltage readings from each  component to the ES buss voltage  All voltages should be   5 volts of  each other  If a DM oC is out of voltage specification  Use ccShell to  recalibrate the voltage    e Refer to appropriate A zure wiring schematics                 P1A31 Starter Performance       Description  If the 12 volt starter fails to crank engine rpm above 125 rpm 3 consecutive times   this fault will be set  The VCU will attempt to start the engine with the ISG  The  HYBRID FAULT light will be on unless the attempt to start with the ISG also  fails  If both starter and ISG starts fail  the HY BRID SERVICE light will flash  and the vehicle will be set to Forced EV mode with delayed traction disabled  depending on the state of charge        Possible Causes  e 12 volt starter failure   e Low 12 volt battery voltage   e Wiring issue to starter   Note  All starter wiring is done by A zure        Diagnostic A ids  e UseBDT  Balance Diagnostic Tool  to manually enable the starter relay  control    e Check power and ground connections including F007  30 Amp  fu
57. iagnostics for APP sensor                 P2164  Throttle   Pedal Position Sensor    B    Maximum Stop Performance       Description  MY 2008  The accelerator pedal track 2 signal is above 91   If no faults are  present on tracks 1  amp  3 then the vehicle will continue to operate normally and the  Hybrid Service light will be on solid    If faults are present for track 1  track 3 or both as well as the P02164  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will be Flash   MY 2009  The accelerator pedal track 2 signal is above 98   The vehicle will be  set to a    Forced Conventional Limp Home M ode    and The HY BRID SERVICE  light will be Flash        Possible Causes  e APP track 2 short to power   e APP track 2 connectivity   e APP sensor fault        Diagnostic A ids  e Refer to appropriate A zure wiring schematics   e Refer to appropriate Ford Diagnostics for APP sensor                 Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 111    AZD    Service Manual    P2165  Throttle   Pedal Position Sensor    C    Maximum Stop Performance       Description     The accelerator pedal track 3 signal is above 91   The vehicle will continue to  operate normally and the Hybrid Service light will be on solid        Possible Causes     e APP track 3 short to power   e APP track 3 connectivity   e APP sensor fault        Diagnostic A ids           e Refer to appropriate A zure wiring schematics
58. ible Causes  Broken or slipping ISG belt    Failed or maladjusted ISG speed sensor   Wiring issue between DM oC and speed sensor   Failed belt tensioner     Failed DM oC speed sensor circuit       Diagnostic Aids  e If accompanied by DTC U0120  follow diagnostic procedures for  U0120 first    e Using the Balance Diagnostic Tool  record ISG speed and engine speed  and compare the values   Note  The ISG spins 2 5 times faster than the engine RMP    e Check ISG belt and tensioner condition    e Refer to diagnostic by Description ISG speed sensor not functioning    e Refer to appropriate A zure wiring schematics                    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 95    AZD Service Manual    POC76 Hybrid Battery System Discharge Time too long       Description  The ESS reports disconnected but the high voltage buss remains above 100 volts  for greater than45 seconds  This indicates a high voltage Powertrain shutdown  fault  The vehicle will be set to    Forced Conventional mode    and the HY BRID  SERVICE light will be on solid        Possible Causes  e ESS contactors did not open   e Buss voltage incorrect        Diagnostic A ids  e Using Balance Diagnostic tool check for any ESS Info codes   e Using Balance Diagnostic tool check for any VCU DTC s        P1A00 Drive motor    A    Critical Fault       Description  The Traction M otor Controller has reported inverter state is    critical fault      Specific fault state reported by ECU cap
59. ice light be on solid        Possible Causes     e Faulty A C DM oC   e Blockage of air flow to cooling fins   e Faulty A C DM oC fan operation           Diagnostic Aids        e Visually inspect A C DM oC cooling fins  A C fan for blockages   e Refer to Azure wiring Schematic           P1A71 A C Motor Stator Over Temperature       Description     The A C motor stator temperature has hit it s    Overheat    limit of 200  C  The  Hybrid Service light be on solid        Possible Causes     e Open circuit on Stator Temperature sensor   e Failed sensor   e Motor has overheated due to blocked air flow to motor           Diagnostic Aids              P1A73 A C Inverter Critical Fault       Description     The A C DM oC has reported inverter state is    critical fault     Specific fault state  reported by V CU captured in freeze frame data and a DM oC Info Code is  stored  The A C will be disabled and the Hybrid Service light be on solid        Possible Causes     e Faulty A C motor Controller   e Faulty A C M otor   e Faulty Wiring           Diagnostic A ids        e Refer to A C DM oC info Codes DM oC Info Codes and freeze frame  data for additional information           P1A74   A C Inverter Fault          Description        The A C DM oC has reported an inverter non critical fault  Specific fault state  reported by V CU captured in freeze frame data and a DM oC Info Code is  stored  The A C will be disabled and the Hybrid Service light be on solid           Azure Dynamics Balance 
60. ics for APP sensor    e Refer to the appropriate Ford Wiring schematics           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 84          AZD Service Manual    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 85    AZD    Service Manual    P0223   Throttle Pedal Position Sensor Switch    B    Circuit High       Description     MY 2008  The VCU has detected that the A ccelerator Pedal track 2 input signal  to the VCU has short Circuit to battery power or short circuit to VREF  5 volt      The Accelerator Pedal track 2 signal voltage to the VCU is greater than 4 67 volts  to set this fault  If no faults are present on tracks 1  amp  3 then the vehicle will  continue to operate normally and the Hybrid Service light will be on solid    If faults are present for track 1  track 3 or both as well as the P0223  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash     MY 2009  The VCU has detected that the A ccelerator Pedal track 2 input signal  to the VCU has short Circuit to battery power or short circuit to VREF   5 volt      The Accelerator Pedal track 2 signal voltage to the VCU is greater than 3 75 volts  to set this fault    the vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash        Possible Causes     e APP track 2 Wiring short circuit to power   e APP track 2 Wiring short circuit to VREF powe
61. is  F orced Disconnect     The ESS has detected a critical system fault  The vehicle will be set to    Forced  Conventional mode    and the HY BRID SERVICE light will be on solid        Possible Causes     ESS internal Failure   Ground Isolation Fault        Diagnostic A ids           Using Balance Diagnostic tool check for any ESS Info codes  repair as  required        P1A22   System Isolation Fault Warning       Description     The ESS continuously monitors isolation resistance between the high voltage buss  and chassis ground  If the Isolation resistance drops below a calibrated threshold  this fault will be set  The Pack state is in Alert  M ode but the contactors are still  closed  The HY BRID SERVICE light will be on solid        Possible Causes     ESS Service disconnect Pin is removed    Internal ESS ground fault    Isolation failure in EPAS M otor or EPAS DM oC    Isolation failure in ISG Motor or ISG DM oC    Isolation failure in Traction M otor or Traction M otor DM oC   High voltage cabling Isolation failure    Isolation failure in DC DC converter    Isolation failure in AC M otor or Controller        Diagnostic A ids           Refer to Isolation Resistance T esting  Refer to ESS Info Codes ESS   Input  DBS Fault             Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 100          AZD Service Manual    P1A30  Hybrid Voltage Measurement Correlation       Description  The Difference between the maximum and minimum reported component 
62. is open  The vehicle will be set to a    Forced Traction  Disable    and The HY BRID SERVICE light will flash              Possible Causes  e Inertia Switch has been tripped   open Circuit   e Faulty Inertia Switch  e Connection or Wiring fault  e Blown Fuse F014   Diagnostic Aids  e Refer to appropriate A zure wiring schematics     e Reset inertia switch and retest             Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 79    AZD    Service Manual    P0121  Throttle   Pedal Position Sensor Switch    A    Circuit Range  Performance       Description     MY 2008  The accelerator pedal tracks 1  amp  2 and 1  amp  3 are different by more than  5   If no faults are present on tracks 2  amp  3 then the vehicle will continue to  operate normally and the Hybrid Service light be on solid     If faults are present for track 2  track 3 or both as well as the P0121  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash     MY 2009  The accelerator pedal tracks 1  amp  2 are different by more than 5   The  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash        Possible Causes     e APP track 1 connectivity   e APP sensor fault        Diagnostic A ids           e Use Balance diagnostic tool to monitor Accelerator Pedal Track 1  2  3  inputs    e Refer to appropriate A zure wiring schematics    e Refer to appropriate Ford Diagnostic
63. l Position Sensor Switch    C    Circuit Range  Performance       Description  MY 2008 only T he accelerator pedal tracks 1  amp 3 and 2  amp  3 are different by more  than 5   If no faults are present on tracks 1  amp  2 then the vehicle will continue to  operate normally and the Hybrid Service light will be on solid                 Possible Causes  e APP track 3 connectivity   e APP sensor fault   e 2008 software loaded in 2009 platform  Diagnostic A ids  e Use Balance diagnostic tool to monitor Accelerator Pedal Track 1  2  3    inputs   Refer to appropriate A zure wiring schematics   Refer to appropriate Ford Diagnostics for APP sensor track 3 signal        P0227  Throttle Pedal Position Sensor  Switch    C    Circuit Low       Description  MY 2008 only The VCU has detected that the A ccelerator Pedal track 3 input  signal to the VCU has a short Circuit to Ground or an Open Circuit  The input  voltage is less than  25 volts  The vehicle will continue to operate normally and  the Hybrid Service light will be on solid                 Possible Causes  e Accelerator Pedal track 3 wiring short circuit to ground   e Faulty APP sensor   e Open circuit   e 2008 software loaded in 2009 platform  Diagnostic A ids  e Refer to appropriate A zure wiring schematics and check all electrical    connections related to Accelerator Pedal track 3    Use BDT to monitor Accelerator Pedal track 3    Refer to appropriate Ford Diagnostics for APP sensor   Refer to the appropriate Ford Wiring sche
64. level  Refer to  https   extranet azuredynamics com for the latest software version              U1032 Software Incompatibility With Starter   Generator Control Module       Description     The SW revision reported by the ISG DM oC is NOT 4  The vehicle will be set  to a    Forced Conventional M ode    and The HY BRID SERVICE light will be on  solid        Possible Causes     e ThelSG DMoC has the incorrect software level loaded           Diagnostic Aids        e Reprogram the  SG DM oC with the correct software level  Refer to  https   extranet azuredynamics com for the latest software version                 Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 117    AZD Service Manual             Margin     Description  These are internal V CU software monitors that aid in development   Possible Causes  e NA   Diagnostic Aids  e Save then Clear faults using Balance Diagnostic Tool   If faults reoccur     record the faults and contact   Email saved DTC   s to techline  azuredynamics com       If faults frequently reappear or are continually active contact  e Product Support   Techline Support   Toll Free Number  1 866 473 1636   Phone  905 607 3486                U1310  U1311  U1312  U1313  1314  U1315  U1316   VCU CPU                           Description  These are internal VCU software monitors that aid in development   Possible Causes  e NA   Diagnostic Aids  e Save then Clear faults using Balance Diagnostic Tool   If faults reoccur     record th
65. m dynamics are too fast for DMoC to control  A rotor speed that  quickly changes or is spinning very fast may need carefully tuned  current loop parameters to avoid over current    Faulty DMoC IGBT problems  A blown IGBT or gate driver may  cause the DM OC to poorly control the current    Current sensor may be damaged           Diagnostic Aids  e       Use ccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software   Use ccShell scope tool to capture current waveforms  ISR1IsU   ISR1lsV and ISR1IsW  at highest sampling rate 10kHz    EE1LoggingRate 1   Also check rotor position waveform   ISR1FluxPosition    Contact  Azure Dynamics Product Support   Techline Support           8   PS_FLT_SOFTWARE_OC    The Software Over Current fault is primarily used for testing or in applications where additional  motor protection is required  The easiest way to trigger a fault is to set an artificially low value  for EE1SoftOCLimit  A ny time the motor current exceeds this value the Software Over Current    fault will be triggered        Description  This fault is flagged if the motor currents exceed the calibratible threshold    EE1SoftOCLimit   Note  that a value less than or equal to zero will disable this fault handling        Possible Causes  e    Wrong or corrupt Software  calibration              Diagnostic Aids  e    Use ccShell to load the latest software and calibrations  Refer to          Azure Dynamics Balance Hybrid 
66. matics        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 87          AZD    Service Manual    P0228   Throttle Pedal Position Sensor Switch    C    Circuit High       Description  MY 2008 only The VCU has detected that the A ccelerator Pedal track 3 input  signal to the VCU has short Circuit to battery power or short circuit to V REF  5  volt     The Accelerator Pedal track 3 input signal voltage to the VCU is greater  than 4 39 volts to set this fault  The vehicle will continue to operate normally and  the Hybrid Service light will be on solid                 Possible Causes  e Accelerator Pedal track 3 Wiring short circuit to power   e Accelerator Pedal track 3 short circuit to VREF power   e Faulty APP sensor   Diagnostic A ids  e Refer to appropriate A zure wiring schematics and check all electrical    connections related to Accelerator Pedal track 3 input signal   Use BDT to monitor AAP track 3    Refer to appropriate Ford Diagnostics for APP sensor    Refer to the appropriate Ford Wiring schematics        P0229   Throttle Pedal Position Sensor Switch    C    Circuit Intermittent       Description  The raw accelerator pedal track 3 slew rate exceeds 300  s  If no faults are  present on tracks 1  amp  2 then the vehicle will continue to operate normally and the  Hybrid Service light will be on solid                 Possible Causes  e APP track 3 connectivity   e APP sensor fault   Diagnostic A ids  e Use Balance diagnostic tool to record 
67. med    Has the fuel injection system been properly maintained     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 71    AZD Service Manual    7 2 Ford PCM  Hybrid VCU Interaction    The hybrid system interacts with many of the Ford base vehicle controls  Always verify the  hybrid VCU DTC s and all items listed in this section before investigating Ford base vehicle  complaints or PATS related issues     Follow the recommended procedures for retrieving and clearing Diagnostic Trouble Codes   DTC  as described in the Ford E 450 5 4 L Service M anual     Note  The PCM Calibration used in the Azure Hybrid V ehicle is not part of the Ford Released  calibrations  Do not Reprogram the Ford PCM with a Factory calibration   For PCM failures contact A zure for a pre programmed Ford PCM    When connecting the Ford IDS service tool to a 2008 or 2009 Balance Production Hybrid  vehicle the technician may need to manually enter the PCM part number  8C2A  12A 650 SD  to  establish communications between the PCM and IDS tool     7 2 1 FORD   DTC P0605 is always present on early production 2008 Balance H ybrid  vehicles     This DTC is set because a development PCM calibration is used in these vehicles  There are no  drivability concerns or fault lights related to the P0605 fault code     7 2 2 FORD  DTC P0743  P0748  P0960  P0962    The hybrid VCU takes control of the transmission control solenoids  If any transmission  solenoid faults are present  remove the C163 
68. n their own   The Pilot input is the Contactor Power supply        posse dust e 12 volt battery  low voltage  below 7 5 volts     e Open circuit    Pilot    contactor 12 volt supply  blown fuse  tripped  inertia switch  intermittent corroded connection     e Open service disconnect access panel contact switch    e ESS 12 volt ignition input  pin    L     shorted to battery 12V       Diagnostic Aids  See pinpoint test below       Test step Result   Action       1 Perform preliminary diagnostics        Yes  Repair and retest     Were any issues found  i  0    Go to step 2       2 Check the Battery Software  e KeyON  do not go to the high volt mode  Yes   e Using the Balance Diagnostic Tool   check the   Go to step 3   software version             No   Is the latest version of software loaded  Load latest software and retest   Refer to https    extranet azuredynamics com  for the latest software   3 Check for Battery Faults   e Key ON  do not go to the high volt mode  Yes   e Using the Balance Diagnostic Tool  Record and   Go to step 4   clear codes   e Cycle the key OFF and back ON  No                   Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 131    AZD    Service Manual       Test step    Result   Action       e Check for faults     Does the Pilot F ault return     No fault found       4 Check Power to the Battery Pack        e Key OFF  connector C053S reconnected   e Key ON  do not go to the high volt mode   e Using the Balance Diagnostic 
69. nce Diagnostic Tool before  continuing with Ford Diagnostics  Refer to Pin Point Tests for Loss of CAN 1 communications  and Loss of CAN 2 communications    The VCU also controls Brake warning lamp  Oil Lamp and Charge Lamp inputs to the  instrument cluster  Refer to the Azure wiring schematics and the Ford diagnostic material for  additional details about these circuits        Instrument Cluster  IC   Diagnostics    There are 2 nuisance faults that may be flagged by the IC    1  U100   Lost communication with ECM  PCM   2  B1352   Ignition key in circuit failure  These faults do not indicate a problem with the IC unless there is another functional issue  observed with the IC   Verify the VCU functionality  communications before investigating any RCM and ABS  communications faults     7 2 5 PATS    The VCU acts as a gateway for the PATS CAN signals to the instrument cluster  If power   ground or CAN communications to the VCU are lost a PATS fault may be set and cause the  vehicle not to operate  Use the Balance Diagnostic tool to check VCU communication and  function first when a PATS fault is present     The vehicles do not support the Ford E 450 CEI option for PATS based on a computer chip   embedded ignition key     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 73    AZD Service Manual    7 2 6 ABS Strategy    If ABS is active or faulty  regenerative braking will be disabled  It will be restored once the  ABS condition clears AND the driver r
70. ngine off        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 91             AZD    Service Manual    POA3C  Drive Motor    A    Inverter Over Temperature       Description     The traction DM oC temperature exceeds 75  C  The instrument Cluster  temperature gauge will read    H    The DM oC plenum fans will be on        Possible Causes     Faulty traction motor DM oC   Blockage of air flow to cooling fins   Faulty DM oC Plenum fan operation        Diagnostic A ids           Use Balance Diagnostic tool to manually turn on Plenum fans to confirm  Operation    Visually inspect traction motor Controller cooling fins  plenum fan  shroud for blockages    Refer to Azure wiring Schematic        POA3E  Generator Inverter Over Temperature       Description     The ISG DM oC temperature has exceed 75  C  The instrument cluster  temperature gauge will read    H     The DM oC plenum fans will be on        Possible Causes     Faulty ISG DM oC  temperature sensor    Blockage of air flow to cooling fins   Faulty DM OC plenum fan operation        Diagnostic A ids        Use BDT to manually turn on Plenum fans to confirm operation              AirCooled   Over temp as Plenum Fan   Plenum  Components   displayed on On temp Fan Off  temperature gauge temp  ISG Inverter 75  C Eng on  30  C  35  C 35  C  Eng Off  40  C                      Visually inspect ISG motor Controller cooling fins  plenum fan shroud  for blockages     Refer to diagnostic by description Ple
71. nostic Aids  e Use Balance Diagnostic tool and record all faults     e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software   e Check for short on high voltage buss        e Isolate each component and retest                 7 6 12 Precharge  Timeout       Description  ESS precharge timeout  This code is set during ESS precharge timeouts  If the  vehicle key is cycled three or more times within a minute  the ESS will timeout  allowing its precharge resistor to cool  After the timeout the ESS will allow  precharge automatically     The link voltage failed to rise to 95  of pack voltage within 1500 ms        peed e Vehicle high voltage buss is shorted  positive to negative      e Component on high voltage buss is drawing current during precharge   when it should be off      e Internal battery pack hardware of software fault        Diagnostic Aids  e Use Balance Diagnostic tool and record all faults   e Reprogram ESS to latest software  clear codes and retest  Refer to  https    extranet azuredynamics com for the latest software   e Check for short on high voltage buss        e Isolate each component and retest              7 6 13M odule  Under Voltage    Description  At least one of the module voltages in the battery pack is less than 7 5 volts and  remains in this condition for 2 sec           Possible Causes           e Hybrid system is over discharging pack  V CU software  traction motor  ISG          
72. ns related to AC switch Input to VCU           P0705   Transmission Range Sensor    A    Circuit  PRNDL Input        Description     The PCM reports lever position fault  The engine will be forced on and stay  running and the Hybrid Service light will be on solid        Possible Causes     e Base vehicle failure L ever position        Diagnostic A ids           e Refer to Ford Diagnostics        P0915  Gear Shift Position Circuit Range Performance       Description     Possible Causes     The PCM reports gear position fault  The vehicle will be set to a    forced  Convention Limp Home M ode    and the HY BRID SERVICE light will flash        e Base vehicle failure with transmission gear position        Diagnostic A ids           e Refer to Ford Diagnostics           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450    89          AZD    Service Manual    POAOF Eng  Engine Failed to Start       Description     The engine has failed to start when cranked above calibrated threshold of 125  rpm  The HY BRID SERVICE light will flash and the vehicle will be set to Forced  EV mode with delayed traction disabled depending on the state of charge        Possible Causes     e Base vehicle engine failure including loss of fuel  spark or sensor signal   e Loss of VCU to PCM enable signal   e Loss of PCM power or ground        Diagnostic A ids           e Verify communication with PCM with either Balance Diagnostic Tool or  IDS  If no communication  test for prope
73. num Fan not functioning           POA77   A C Position Sensor Circuit       Description     The reported air conditioning speed reported by the A C DM oC is less than 5 rpm  and the A C reported torque is greater than 10 Nm        Possible Causes     Failed A C motor speed sensor        Diagnostic A ids              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 92             AZD    Service Manual    POA7E  Hybrid Battery Pack Over Temperature       Description     Maximum ESS module temperature has exceeded 70   C  The temperature will be  inthe    H           Possible Causes     e Low temp coolant pump inoperable              e Radiator fans inoperable    e Low coolant level   e Blocked or kinked coolant hose   e Internal ESS M odule failure   Diagnostic A ids  e Using Balance Diagnostic tool check for any ESS Info codes     e Using Balance Diagnostic tool check ESS module temperatures  If all  temperatures are close to being equal than look for external cooling  system issue  If module temperature is greater than 10  C higher than the  other modules  replace ESS    e Check Electronics cooling level or kinked hose    e Using the Balance Diagnostic Tool  manually activate the low  temperature cooling pump and Radiator Fans to confirm operation    e Check radiator fan fuse F039  80 amp     e Check Coolant pump fuse F011  10 amp  and K 3 low Temp Cooling                             Pump Relay   a  Hose  L 3 60m  Ww Hose I Hose s   4   Hose  L 4 0
74. oblem  If the CAPS_ CHARGED signal is still noisy   the contactor state may still register a fault           Diagnostic Aids        e Verify that EE2Contactorlsinternal   0    e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software  if fault  persists  replace controller    e Look at variable ISR 2ContactorState  it should be EXTERNAL  if  noisy  it may be possible to trigger EXTERNAL CRITICAL FAULT   in which case you need to resolve the noise issue            5   PS_FLT_CHARGED_ERROR       Description     The  Charged Error  fault is often observed as a nuisance in systems with a lot  of noise or bad grounding        Possible Causes     e Problem with vehicle 12 volt supply  input to DM oC    Bad grounding  cable routing  or external noise   Incorrect software          Diagnostic Aids        e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software  e Verify grounding is correct            6   PS_ FLT HARDWARE_O volt       Description     The hardware over voltage fault is caused by the controller hardware detecting a  voltage above 90  of full scale  500 volts   This almost always corresponds to  450 volts DC   The purpose of the hardware protection is to stop the DM OC  from switching when it detects a dangerously high voltage  In general this  protection is faster than any software over voltage protection which is usually  set to a
75. orage System  Info Codes  1  Active Codes  the code is currently active     2  Stored Codes  ESS stored codes are saved in the Battery Control Module  BCM   memory until they are manually cleared  Active or stored critical codes may also be  accompanied by aVCU DTC     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 74    AZD Service Manual    7 3 3 DMoC Info Codes    When a DM oC fault is set  the VCU sets a fault and also stores an additional DM oC info code in  the freeze frame data and in the DM OC INFO CODES tab of the Balance Diagnostic Tool   BDT      DM oC faults are put into 2 categories     a Non critical Faults   EE3LastError or EE3PSFaults   0 127  can be reset by the V CU  and the hybrid system affected will continue to operate normally until the fault  occurrence exceeds a predetermined rate     b  Critical Faults   EE3LastErroro r EE3PSFaults   greater thanl28  A DM oC critical  fault will disable the DMoC until the following power cycle    The fault history EE3PSFaultsl 2  3  provides the enumerated history for the most recent 4 fault  entries stored  whereas the fault history EE 3LastError provides a bit field error code history  also  4 entries  that can log multiple faults simultaneously  K eep in mind that for the majority of  faults  both fault histories correlate with each other  ie  if only 1 fault occurred at any given time   but some faults are ONLY displayed under EE 3PSF aults  and so they should be the first ones to  be
76. r   e Faulty APP sensor       Diagnostic A ids     e Refer to appropriate A zure wiring schematics and check all electrical  connections related to Accelerator Pedal track 2 input signal    e UseBDT to monitor Accelerator Pedal track 2    e Refer to appropriate Ford Diagnostics for APP sensor    e Refer to the appropriate Ford Wiring schematics        P0224  Throttle   Pedal Position Sensor Switch    B    Circuit Intermittent       Description     MY 2008  The raw accelerator pedal track 2 slew rate exceeds 300  s  If no  faults are present on tracks 1  amp  3 then the vehicle will continue to operate  normally and the Hybrid Service light will be on solid   If faults are present for track 1  track 3 or both as well as the P0224  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash     MY 2009  The raw accelerator pedal track 2 slew rate exceeds 300  s  The  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HYBRID SERVICE light will flash        Possible Causes     e APP track 2 connectivity   e APP sensor fault        Diagnostic A ids           e Use Balance diagnostic tool to record APP track 1  2  3 and compare  signals    e Refer to appropriate A zure wiring schematics    e Refer to appropriate Ford Diagnostics for APP sensor track 2 signal           Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 86       AZD    Service Manual    P0226   Throttle   Peda
77. r powers  grounds  If other  CAN communications faults are present  troubleshoot and resolve them  first    e C163 conventional mode jumper and test for vehicle start  If no start   refer to Ford diagnostics    e Refer to appropriate A zure wiring schematics        POA1B  Drive Motor    A    Control Module                   Description  The traction motor DM oC state does not match the state being commanded by the VCU    The vehicle will be set to a    Forced Conventional Mode    and The HY BRID SERVICE  light will be on solid    Possible e Traction motor DM oC was just reprogrammed to new software without the   Causes  V oltage calibration performed    e Faulty traction motor DM oC    e NoHV toDMoC  blown Fuse     e Incorrect DM oC software   Diagnostic e Compare the ESS buss voltage to the reported voltage from the traction motor  Aids  DM OC and use ccShell to recalibrate DM oC voltage  Ensure that Save B ox    Config has been performed   Voltage Calibration    DMoC Reported Voltage  V     324 02      Measured Voltage    Calibrate  BoxConfiguration DCVoltageScaleFactor  T_LINT C     2 4043    less Box Config    Use ccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software   Contact A zure Tech ine techline  azuredynamics com for support              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 90          AZD    Service Manual    POA1E  Starter Generator Control Module         
78. r reported speed   Check sensor function  refer to          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 97          AZD    Service Manual    P1A10  Generator Inverter Critical Fault       Description     The ISG DM oC has reported the state is    critical fault     Specific fault state  reported by DM oC is captured in V CU freeze frame data ISG Info code  The  Body Builder AC will be shut off  the engine will be forced on and stay running  and the Hybrid Service light will be on solid        Possible Causes     e Faulty ISG DM oC   e Faulty ISG M otor        Diagnostic A ids        e Refer to DM oC info Codes DM oC Info Codes              P1A11 Generator Inverter Fault       Description     The ISG DM oC has reported inverter state is    non critical fault     Specific fault  state reported by DM OC is captured in V CU freeze frame data ISG Info code   The HYBRID SERVICE light will be on solid  If the fault monitor count exceeds  3  the Body Builder AC will be shut off  and the engine will be forced on and stay  running        Possible Causes     e Faulty ISG DMoC   e Faulty ISG Motor   e Wiring fault        Diagnostic A ids        e Refer to DMoC info Codes DM oC Info Codes and freeze frame data for  additional information              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 98          AZD Service Manual    P1A12   Generator Stator Over Temperature       Description  The ISG stator temperature has hit it
79. redynamics com for the latest software  e  f software level is correct replace DM oC           206   DMOC_FAULT_CAUSE_UNKNOWN_CAN_FAULT       Description     This is a CAN fault  that is not specifically enumerated in the P1  extension module  refer to the ISR2CA NComState for more  information        Possible Causes     e Can Bus Errors or other problems  grounding           Diagnostic A ids        e Verify that ISR2CANComState is not ONLINE   e Useother CAN analyzer tool to look for CAN bus errors  CA NK ing for          Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450                127       AZD Service Manual    example    e Check grounding and CAN wiring                  208   DMOC_FAULT_CAUSE_CAN_BUS ERROR          Description  This CAN fault is triggered if ISR2CANComState is not ONLINE  Possible Causes  Can Bus Errors or other problems  grounding   DM oC failure          Diagnostic A ids  Verify that ISR2CANComState is not ONLINE   Use other CAN analyzer tool to look for CAN bus errors  CANK ing for  example      e Check grounding and CAN wiring              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 128    AZD Service Manual    7 6 ESS INFO Codes    The ESS  Energy Storage System  Info codes are the component level faults that are monitored  and stored in the ESS  The VCU monitors the fault status of the ESS and will set and store  system level faults based on the state and level of fault stored in the ES
80. rflowing  when the system is at the maximum operating temperature  Fluid will need to be  removed from the reservoir if the reservoir is overfilled beyond the prescribed marks     12 volt battery condition and state of charge have been tested     AIl electrical connectors connected and secure     Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 70    AZD Service Manual    10     11     Test for blown fuses    Check all connectors to ensure they are properly mated    Check that the Inertia Switches have not been tripped    Look for other wiring concerns    Check all ground connections to ensure they are clean and tight   V acuum hoses are connected     All intake and exhaust components are secure and not leaking   Check for hybrid vehicle operation and verify if any service lights are on     If HYBRID ENABLED LED is OFF   check that the conventional mode jumper  connector C163P  has not been removed from under the dash  it is typically tie strapped  to the steering column      Check for DTCs and info codes on PCM  ESS and VCU  Repair any Faults before  proceeding     Fuel lines secure and not leaking   Verify fuel supply     Verify there is   tank or greater of fuel  and does the fuel pump operate   Has the fuel filter been serviced     Verify engine condition     Is the compression good with less than a 10  variation between cylinders   V erify that the valve train is operating as per manufactures specifications   Has normal maintenance been perfor
81. rid electric Vehicle   2008  2009  2010 Ford E 450 81       AZD    Service Manual    P0123   Throttle Pedal Position Sensor Switch    A    Circuit High       Description     MY 2008  The VCU has detected that the A ccelerator Pedal track 1 input signal  to the VCU has short Circuit to battery power or short circuit to VREF  5 volt      The Accelerator Pedal track 1 signal voltage to the VCU is greater than 4 78 volts  to set this fault  If no faults are present on tracks 2  amp  3 then the vehicle will  continue to operate normally and the HY BRID SERVICE light will be on solid     If faults are present for track 2  track 3 or both as well as the P0123  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash     MY 2008  The VCU has detected that the A ccelerator Pedal track 1 input signal  to the VCU has short Circuit to battery power or short circuit to VREF  5 volt      The Accelerator Pedal track 1 signal voltage to the VCU is greater than 4 95 volts  to set this fault     The vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash        Possible Causes     e Accelerator Pedal track 1 Wiring short circuit to power   e Accelerator Pedal track 1 Wiring short circuit to VREF power   e Faulty APP sensor       Diagnostic A ids           e Refer to appropriate A zure wiring schematics and check all electrical  connections related to A ccelerator Pedal track 1 inp
82. ropriate A zure wiring schematics                       U0121 ABS  Lost Communication with Anti Lock Brake System  ABS  Control Module       Description  The VCU will start to monitor this CAN message 5 seconds after the ABS module  is powered up  If any ABS message is arriving too slowly  or any message is not  being received at all  this fault will set    The VCU will disable the regenerative braking  The hybrid service light will be  on solid and the vehicle will continue in hybrid operation           Possible Causes  e Failed Can  terminator resistor    e Failed ABS module    e Faulty power and ground circuits to ABS module    e Faulty wiring  routing or connection problems on CAN 1   Diagnostic Aids  e Perform Ford base vehicle diagnostics and confirm ABS system is    operating normally   e Refer to pinpoint test procedure Loss of CAN 1 communications                    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 115    AZD    Service Manual    U0131  Lost Communication with Power Steering Control Module       Description     The VCU has detected a message period greater than 2x specified rate  or no  message received at all for any EPAS CAN message  The engine will be forced  on and stay running and the Hybrid Service light be on solid        Possible Causes     Electrical noise on CAN 2    Can terminator resistor failure CAN 2   Faulty EPAS motor Controller    Failed power or grounds to EPAS DM oC   Wiring or connection problems        
83. s    Overheat    limit of 200    C  The instrument cluster temperature gauge will read    H           Possible Causes  e Open circuit on stator temperature sensor   e Failed sensor   e ISG motor has overheated due to blocked air flow to motor        Diagnostic A ids  e Check wiring for open circuits and shorts to ground    e Inspect for blocked air flow to ISG motor   Cooling fins    e Measure resistance across C261P pin H and Pin  resistance should be   9 4 Kohm   21  C refer to chart below  If sensor out of spec  visually  inspect for damaged wiring to sensor  If wiring ok  replace ISG M otor    e Refer To Azure Wiring Schematic                 ISG  Temperature Sensor   Resistance Vs Temperature               Resistance  Kohm        Resistance  KOhm                          0 50 100 150 200 250  Temperature  F     P1A20 Battery Control Module Fault       Description  The VCU has detected that the ESS pack state is  Alert  The ESS has detected a non critical system fault  The HY BRID SERVICE light  will be on solid        Possible Causes  e ESS internal Failure   e Failure of ESS inputs        Diagnostic A ids  e Using Balance Diagnostic tool check for any ESS Info codes  repair as  required   e Refer to appropriate A zure wiring schematics                    Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 99    AZD    Service Manual    P1A21 Battery Control Module Critical Fault       Description     The VCU has detected that the ESS pack state 
84. s for APP sensor track 1 signal        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 80       AZD    Service Manual    P0122   Throttle Pedal Position Sensor Switch    A    Circuit Low       Description     MY 2008  The VCU has detected that the Accelerator Pedal track 1 input signal  to the VCU has a short Circuit to Ground or an Open Circuit  The input voltage is  less than 0 16 volts   If no faults are present on tracks 2  amp  3 then the vehicle will continue to operate  normally and the Hybrid Service light be on solid    If faults are present for track 2  track 3 or both as well as the P0122  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash     MY 2009  The VCU has detected that the A ccelerator Pedal track 1 input signal  to the VCU has a short Circuit to Ground or an Open Circuit  The input voltage is  less than 0 3 volts    The vehicle will be set to a    Forced Conventional Limp Home M ode    and The  HY BRID SERVICE light will flash        Possible Causes     APP Sensor track 1 wiring short circuit to ground   Faulty APP sensor   Open Circuit        Diagnostic A ids           Refer to appropriate A zure wiring schematics and check all electrical  connections related to A PP input    Use BDT to monitor Accelerator Pedal track 1    Refer to appropriate Ford Diagnostics for APP sensor    Refer to the appropriate Ford W iring schematics        Azure Dynamics Balance Hyb
85. scription  The EPAS motor stator temperature has hit it s    Overheat    limit of 200  C   The instrument cluster temperature gauge will bein the    Red    or    H           Possible Causes  e Open circuit on Stator Temperature sensor   e Failed sensor   e Motor has overheated due to blocked air flow to motor        Diagnostic A ids  e With the Motor at Room temperature  M easure resistance across C 338P  pins 9 and pin 10 resistance should be less than lohms  if greater than1  ohms replace EPAS M otor    e  f motor temperature sensor is within spec Refer To Azure Wiring  Schematic and repair wiring issue                 P1A43  Electric Power Steering Inverter Critical Fault       Description  The traction DM oC has reported inverter state is    critical fault     Specific fault  state reported by ECU captured in freeze frame data and a DM oC Info Codeis  stored  The engine will be forced on and stay running and the Hybrid Service light          will be on solid   Possible Causes  e Faulty EPAS motor Controller   e Faulty EPAS M otor   e Faulty Wiring   Diagnostic Aids  e Refer to M otor Controller info Codes DM oC Info Codes and freeze frame       data for additional information                Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 103    AZD    Service Manual    P1A44  Electric power Steering Inverter Fault       Description     The EPAS DM oC has reported an inverter non critical fault  Specific fault state  reported by ECU captured in
86. se and  K 7 starter relay    e Refer to appropriate A zure wiring schematics    e Jumper pin 30 and pin 87 of K 7 the starter relay to confirm wiring to the  starter                 Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 101    AZD    Service Manual    P1A32  Hybrid Control Module Command Engine Pedal Correlation       Description  This is an engine Pedal Command Fault  The difference between VCU s PCM  APP command and actual PCM APP feedback from the PCM exceeds 10  for  more than 2 seconds    The vehicle will be set to    Forced Conventional Limp Home mode    and the  HYBRID SERVICE light will flash        Possible Causes     Faulty wiring between VCU and PAC circuit   Faulty wiring between PAC and PCM circuit   PAC power or ground faults    Faulty PAC module        Diagnostic A ids           Check PCM for APP faults    To verify APP functionality  use the Balance Diagnostic Tool in     Diagnostics M ode    to manually control individual PAC APP command  outputs and confirm they match the corresponding APP signals read by  the IDS tool    If the AAP readings in the above step do not match  then remove  accelerator pedal intercept at C122P and remove connector C238 at APP  sensor and test Ford wiring by installing C122S into the APP  Clear  faults with IDS tool and verify APP operation following Ford vehicle  diagnostics   if the pedal functions normally  then the problem is with the  Hybrid wiring or PAC module on the hybrid harness    
87. stic A ids           If DTC POC2F is present  investigate first    If ISG Info codes are present  investigate them first    Using Azure Balance Diagnostic T ool record the ISG     Rotational  Speed    and PCM      Engine Speed    confirm that the signal profiles are the  same  The ISG    Rotational Speed    should be 2 5 x the Engine Speed     If  the profiles match then diagnose a ISG DM oC or ISG Motor issue  If the  profiles do not match or the ISG Rotational Speed is erratic when  compared to Engine Speed  look for slipping belt  miss adjusted of Faulty  ISG Speed sensor    Refer to appropriate A zure wiring schematics    Check ISG speed sensor adjustment and operation  refer to ISG speed  sensor not functioning           POAAG  Hybrid Battery Voltage System Isolation Fault       Description  The ESS continuously monitors isolation resistance between the high voltage buss  and chassis ground  If the isolation resistance is less than 2 M ohms at key on or  less than 500 K ohms while the vehicle is running this fault will be set  The  vehicle will be set to    Forced Conventional mode    and the HY BRID SERVICE  light will be on solid        Possible Causes  e    ESS Service disconnect Pin is removed    Internal ESS ground fault    Isolation failure in EPAS M otor or EPAS Motor Controller   Isolation failure in ISG M otor or ISG M otor Controller   Isolation failure in Traction M otor or Traction M otor Controller   High Voltage cabling Isolation failure    Isolation failur
88. the ESS has been powered on by the VCU   The VCU will monitor the ESS CAN messages  If any ESS message is arriving  too slow  or any message is not being received at all  this fault will set  The  vehicle will be set to    Forced Conventional mode    and the HY BRID SERVICE  light will be on solid        Possible Causes  e Can terminator resistor failure CAN 2   e Failed ESS    e Failed power or grounds to ESS    e Wiring or connection problems        Diagnostic A ids     Follow diagnostic by description ESS not communicating   e Follow diagnostic by description Loss of CAN 2 communications   e Refer to appropriate A zure wiring schematics                       Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 114    AZD Service Manual    U0120 Lost Communication with Starter   Generator Control Module       Description  The VCU has detected a message is being received too slowly  or no message is  received at all for any ISG CAN message  The Body Builder AC will be shut off   the engine will be forced on and stay running  and the Hybrid Service light will be       on solid   Possible Causes  e CAN terminator resistor failure CAN 2   e Faulty ISG DMoC   e NoHV power  blown fuse    e Failed 12 volt power or grounds to ISG DM oC   e Wiring or connection problems        Diagnostic A ids  e Follow diagnostic by description ISG DM oC not functioning or not  communicating    e Follow diagnostic by description Loss of CAN 2 communications    e Refer to app
89. tured in freeze frame data and a DM OC  Info Code is stored  The vehicle will be set to    Forced Conventional mode    and  the HY BRID SERVICE light will be on solid           Possible Causes  e Faulty traction motor Controller  DM oC    e Faulty Traction M otor   e Faulty Wiring   Diagnostic Aids  e Refer to M otor Controller info Codes DM oC Info Codes and freeze frame       data for additional information                 P1A01 Drive Motor    A    Inverter Fault       Description  The traction motor DM oC has reported an DM oC non critical fault  Specific fault  state reported by ECU captured in freeze frame data and a DM oC Info Codeis  stored  The Hybrid Service light will be on solid  If the fault monitor count  exceeds three  the vehicle will be set to    Forced Conventional mode    and the   HY BRID SERVICE light will be on solid           Possible Causes  e Faulty traction motor Controller   e Faulty traction M otor   e Faulty Wiring   Diagnostic Aids  e Refer to M otor Controller info Codes DM oC Info Codes and freeze frame       data for additional information              Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 96       AZD    Service Manual    P1A02   Drive Motor    A    Stator Over Temperature       Description  The traction motor stator temperature has hit it s    Overheat    limit of 200  C   The instrument cluster temperature gauge will bein the    Red    or    H                    Possible Causes  e Open circuit on Stator
90. ult is flagged if the DM oC receives an external disable signal from the  VCU via a hardware input signal while the Powerstage was enabled        Possible Causes     Problem with external disable wiring  If the external disable signal is not  wired properly  then noise could trigger this fault   Wiring connectivity issue between VCU and DM oC          Diagnostic Aids        e Check that the External Disable input to the DM oC is wired properly   e Verify VCU shutdown sequencing is correct         131   PS_FLT_KERNEL_DISPATCHER_ERROR       Description     The DM oC has run out of code execution time  Usually only seen during  software development        Possible Causes     e Wrong or corrupt Software  calibration  e Motor controller failure           Diagnostic Aids        e UseccShell to load the latest software and calibrations  Refer to  https   extranet azuredynamics com for the latest software  e  f software level is correct replace DM oC           132   PS_FLT_UNDEFINED_CASE_ERROR       Description     This fault indicates a corruption of the powerstage state variable  This  variable has been set to an invalid state  All changes in software to the  powerstage state variable should happen through the powerstage FSM    No other code should write to the state        Possible Causes     e Wrong or corrupt Software  calibration  e Motor controller failure           Diagnostic Aids        e UseccShell to load the latest software and calibrations  Refer to  https   extranet azu
91. ut signal    e Use Balance Diagnostic tool to monitor Accelerator Pedal track 1    e Refer to appropriate Ford Diagnostics for APP sensor    e Refer to the appropriate Ford Wiring schematics        Azure Dynamics Balance Hybrid electric Vehicle   2008  2009  2010 Ford E 450 82       AZD Service Manual    P0124  Throttle   Pedal Position Sensor Switch    A    Circuit Intermittent  Description  MY 2008 The accelerator pedal track 1 slew rate exceeds 300  s  If no faults are  present on tracks 2  amp  3 then the vehicle will continue to operate normally and the    Hybrid Service light be on solid   If faults are present for track 2  track3 or both as well as the P0124  then the  vehicle will be set to a    Forced Conventional Limp Home M ode    and The    HYBRID SERVICE light will flash        MY 2009  The accelerator pedal track 1 slew rate exceeds 300  s  The vehicle  will be set to a    Forced Conventional Limp Home M ode    and The HY BRID    SERVICE light will flash           Possible Causes  e APP track 3 connectivity   e APP sensor fault   Diagnostic A ids  e Use Balance diagnostic tool to record APP track 1  2  3 and compare  signals     e Refer to appropriate A zure wiring schematics   e Refer to appropriate Ford Diagnostics for APP sensor track 1 signal                 P0217 ENG  Engine Coolant Over Temperature Condition   Description  The VCU has detected that engine temperature has exceeded 123  C  The  temperature gauge in the instrument cluster will read    H     t
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Samsung Galaxy Young 2 คู่มือการใช้งาน  Samsung SCX-1630V User Manual  CP-AW3019WNM - Wedgwood AV Ltd.  XM140HD XM160HD  NTSS User Manual - Documentation  CyberPower COMMCARD300  28390-10 CP170 french canadian:23702-B-10 CP155  HeartSine® HeartSine®  Samsung DV209 User's Manual  Istruzioni d’uso    Copyright © All rights reserved. 