Home
Keysight 33210A 10 MHz Function/Arbitrary Waveform
Contents
1. Keysight 33210A 10 MHz Function Arbitrary Waveform Generator KEYSIGHT KEYSIGHT TECHNOLOGIES Data Sheet 10 MHz Sine and Square waveforms Pulse Ramp Triangle Noise and DC waveforms Optional 14 bit 50 MSa s 8K point Arbitrary Waveform Generator AM FM and PWM modulation types Linear amp logarithmic sweeps and burst operation 10 mVpp to 10 Vpp amplitude range Graph mode for visual verification of signal settings Connect via USB GPIB and LAN Fully compliant to LX Class C specification LXl Uncompromising performance at an affordable price The Keysight Technologies Inc 33210A function arbitrary waveform generator is the latest addition to the 332XX family Waveforms are generated using direct digital synthesis DDS technology which creates stable accurate low distortion sine waves as well as square waves with fast rise and fall times up to 10 MHz and linear ramp waves up to 100 kHz For user defined waveforms Option 002 provides 14 bit 50 MSa s 8K point arbitrary wave form generation Pulse generation The 33210A can generate variable edge time pulses up to 5 MHz With variable period pulse width and amplitude the 33210A is ideally suited to a wide variety of applications requiring a flexible pulse signal Custom waveform generation Option 002 The optional 8K point arbitrary waveform generator Option 002 can be used in the 33210A to generate complex custom waveforms With
2. 1 mHz to 5 MHz Pulse width 40 ns minimum period lt 10 s 10 ns resolution Variable edge time 20 ns to 100 ns Overshoot lt 2 Jitter RMS 300 ps 0 1 ppm of period Noise Bandwidth 7 MHz typical Measurement Characteristics continued 8K point arbitrary waveform generator Option 002 Frequency range 1 mHz to 3 MHz Waveform length 2 to 8 k points Amplitude resolution 14 bits including sign Sample rate 50 MSa s Min rise fall time 70 ns typical Linearity lt 0 1 of peak output Settling time lt 500 ns to 0 5 of final value Jitter RMS 6 ns 30 ppm Non volatile memory 4 waveforms Common characteristics Frequency Accuracy 10 ppm 3 pHz in 90 days 20 ppm 3 pHz in 1 year Resolution 1 pHz internal 1 mHz user Amplitude Range 10 mVpp to 10 Vpp into 500 20 mVpp to 20 Vpp into open circuit Accuracy 2 of setting at 1 kHz 1 mVpp Units Vpp Vrms dBm Resolution 3 digits DC offset Range 5 V into 500 peak AC DC 10 V into open circuit 2 of offset setting 0 5 of amplitude Accuracy 2mV Resolution 3 digits Main output Impedance 50 0 typical Isolation 42 Vpk maximum to earth Protection Short circuit protected overload automatically disables main output External frequency reference Modulation AM Carrier waveforms Sine Square Source Internal Exte
3. Accessories 34131A Carrying case 34161A Accessory pouch 34190A Rackmount kit 34191A Dual flange kit 2U 34194A Dual lock link kit 05 Keysight 33210A 10 MHz Function Arbitrary Waveform Generator Data Sheet myKeysight LX WARRANTY myKeysight www keysight com find mykeysight A personalized view into the information most relevant to you www lxistandard org LAN eXtensions for Instruments puts the power of Ethernet and the Web inside your test systems Keysight is a founding member of the LXI consortium Three Year Warranty www keysight com find ThreeYearWarranty Keysight s commitment to superior product quality and lower total cost of ownership The only test and measurement company with three year warranty standard on all instruments worldwide Keysight Assurance Plans www keysight com find AssurancePlans Up to five years of protection and no budgetary surprises to ensure your instruments are operating to specification so you can rely on accurate measurements www keysight com quality Keysight Electronic Measurement Group DEKRA Certified ISO 9001 2008 Quality Management System Keysight Channel Partners www keysight com find channelpartners Get the best of both worlds Keysight s measurement expertise and product breadth combined with channel partner convenience www keysight com find 33210a For more information on Keysight Technologies products applications or services please conta
4. MHz clock to another 33210A or to a Keysight 33220A or Keysight 33250A Phase adjustments can be made from the front panel or via a computer interface allowing precise phase calibration and adjustment 02 Measurement Characteristics Waveforms Standard Sine Square Ramp Triangle Pulse Noise DC Built in arbitrary wave Exponential rise forms available only Exponential fall Negative with Option 002 ARB ramp Sin x x Cardiac Waveform characteristics Sine Frequency range 1 mHz to 10 MHz Amplitude relative to 1 kHz Flatness lt 100 kHz 0 1 dB 100 kHz to 5 MHz 0 2 dB 5 MHz to 10 MHz 0 3 dB Harmonic distortion lt 1Vpp 2 1 Vpp DC to 20 kHz 70 dBc 70 dBc 20 kHz to 100 kHz 65 dBc 60 dBc 100 kHz to 1 MHz 50 dBc 45 dBc 1 MHz to 10 MHz 40 dBc 30 dBc Total harmonic distortion DC to 20 kHz 0 04 Spurious non harmonic DC to 1 MHz 70 dBc 1 MHz to 10 MHz 70 dBc 6 dB octave Phase noise 10 kHz offset 115 dBc Hz typical Square Frequency range 1 mHz to 10 MHz Rise fall time 20 ns Overshoot lt 2 Variable duty cycle 20 to 80 to 5 MHz 40 to 60 to 10 MHz Asymmetry 1 of period 5 ns 50 duty Jitter RMS 1 ns 100 ppm of period Ramp triangle Frequency range 1 mHz to 100 kHz Linearity lt 0 1 of peak output Variable symmetry 0 0 to 100 0 Pulse Frequency range
5. 14 bit resolution and a sampling rate of 50 MSa s the 33210A gives you the flexibility to create the waveforms you need It also lets you store up to four waveforms in nonvolatile memory The Keysight IntuiLink arbitrary wave form software allows you to easily create edit and download complex waveforms using the waveform editor Or you can capture a waveform using IntuiLink for Oscilloscopes and send it to the 33210A for output To find out more about IntuiLink visit www keysight com find intuilink Easy to use functionality Front panel operation of the 33210A is straight forward and user friendly You can access all major functions with a single key or two The knob or numeric keypad can be used to adjust frequency ampli tude offset and other parameters You can even enter voltage values directly in Vpp Vrms dBm or as high and low levels Timing parameters can be entered in Hertz Hz or seconds Internal AM FM and PWM modulation make it easy to modulate waveforms with out the need for a separate modulation source Linear and logarithmic sweeps are also built in with sweep rates selectable from 1 ms to 500 s Burst mode operation allows for a user selected number of cycles per trigger GPIB LAN and USB interfaces are all standard plus you get full program mability using SCPI commands External frequency reference Option 001 The 33210A external frequency refer ence lets you synchronize to an external 10
6. Frequency 10 MHz selectable Level 632 mVpp Pulse width gt 100 ns 0 dBm typical Input impedance gt 10 k0 DC coupled Impedance 50 0 typical Latency lt 500 ns AC coupled Jitter rms 6 ns 3 5 ns for pulse Phase offset Trigger output Range 360 to 360 Level TTL compatible into Resolution 0 001 21k0 Accuracy 20 ns Pulse width gt 400 ns Output impedance 50 Q typical Maximum rate 1 MHz Fanout lt 4 Keysight 33210As or equivalent 03 Footnotes 1 Add 1 10th of output amplitude and offset spec per C for operation outside the range of 18 to 28 C 2 Autorange enabled 3 DC offset set to 0 V 4 Spurious output at low amplitude is 75 dBm typical 5 Add 1 ppm C average for operation outside the range of 18 to 28 C 6 Sine and square waveforms above 3 MHz are allowed only with an infinite burst count 7 Only available if Option 002 is installed Measurement Characteristics continued Programming times typical General Configuration times USB LAN GPIB Power supply Cat Il Function change 120ms 120 ms 120 ms 100 to 240 V Frequency change 2 ms 3ms 2ms 50 60 Hz 5 10 Amplitude change 30ms 30ms 30ms 100 to 120 V 400 Hz Select user arb 130ms_ 130 ms 130 ms 10 Arb download times Binary transfer Power consumption 50 VA max Option 002 Operating IEC 61010 USB LAN GPIB environment Pollution Degree 2 2 k points 5ms 9ms 10ms Indoor Locatio
7. ct your local Keysight office The complete list is available at www keysight com find contactus Americas Canada 877 894 4414 Brazil 55 11 3351 7010 Mexico 001 800 254 2440 United States 800 829 4444 Asia Pacific Australia 800 629 485 China 800 810 0189 Hong Kong 800 938 693 India 800 112 929 Japan 0120 421 345 Korea 080 769 0800 Malaysia 800 888 848 Singapore 800 375 8100 Taiwan 0800 047 866 Other AP Countries 65 6375 8100 Europe amp Middle East Austria 0800 001122 Belgium 0800 58580 Finland 0800 523252 France 0805 980333 Germany 0800 6270999 reland 1800 832700 srael 1 809 343051 taly 800 599100 Luxembourg 32 800 58580 etherlands 0800 0233200 Russia 8800 5009286 Spain 0800 000154 Sweden 0200 882255 Switzerland 0800 805353 Opt 1 DE Opt 2 FR Opt 3 IT United Kingdom 0800 0260637 For other unlisted countries www keysight com find contactus BP 06 16 14 KEYSIGHT TECHNOLOGIES This information is subject to change without notice Keysight Technologies 2012 2014 Published in USA August 2 2014 5989 8926EN www keysight com
8. n 4 k points 8ms 15ms 20ms Operating 0 to 55 C 8 k points 14ms__27ms_ 40 ms temperature Operating humidity 5 to 80 RH non condensing Operating altitude Up to 3000 meters Storage temperature 30 to 70 C State storage Power off state memory automatically saved Four user configurable stored states Interface LAN LXI C Ethernet 10 100 USB 2 0 GPIB Language SCPI 1993 IEEE 488 2 Dimensions W x H x D Bench top 261 1 mm x 103 8 mm x 303 2 mm Rack mount 212 88 mm x 88 3 mm x 272 3 mm Weight 3 4 kg 7 5 lbs Safety designed to UL 1244 CSA 1010 EN61010 EMC tested to MIL 461C EN55011 EN50082 1 Vibration and shock MIL T 28800 Type III Class 5 Acoustic noise 30 dBa Warm up time 1 hour 04 Ordering Information Keysight 33210A 10 MHz function arbitrary waveform generator Accessories included Operating manual service manual quick reference guide IntuiLink waveform editor software test data USB cable and power cord see language option Options Opt 001 External timebase reference Opt 002 8K point arbitrary waveform generator ANSI Z540 calibration Taiwan Chinese manual Opt AB1 Korea Korean manual Opt AB2 China Chinese manual Opt ABA English English manual Opt ABD Germany German manual Opt ABF France French manual Opt ABJ Japan Japanese manual Opt PLG Continental European power cord Opt AGJ Opt ABO Other
9. rnal Internal modulation Sine Square Ramp Triangle Noise Arb 2 mHz to 20 kHz Depth 0 0 to 120 0 FM Carrier waveforms Sine Square Source Internal External Internal modulation Sine Square Ramp Triangle Noise Arb 2 mHz to 20 kHz Deviation DC to 5 MHz PWM Carrier waveforms Pulse Source Internal External Internal modulation Sine Square Ramp Triangle Noise Arb 2 mHz to 20 kHz Deviation 0 to 100 of pulse width External modulation input for AM FM PWM Voltage range 5 V full scale Input impedance 5 KQ typical Bandwidth DC to 20 kHz Sweep Waveforms Sine Square Ramp Type Linear or Logarithmic Direction Up or Down Sweep time 1 ms to 500 s Trigger source Single External or Internal Marker Falling edge of sync signal programmable frequency Burst Waveforms Sine Square Ramp Type Counted 1 to 50 000 cycles Infinite Gated Start stop phase 360 to 360 Internal period 1 us to 500 s Option 001 Gate source External trigger Rear panel input Trigger source Single External or Internal Lock range 10 MHz 500 Hz Level 100 mVpp to 5 Vpp Trigger characteristics Impedance 1 kQ typical Trigger input Lock time lt 2 seconds Input level TTL compatible Rear panel output Slope Rising or Falling