Contents
1. 2 Press the PRINT key The current value for OP1 is displayed 3 Press ENTER to accept this value OR Key in a value and press the ENTER key OPI is displayed Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 3 for each output Press ESC key to exit the cutoffs setup N OV e As you apply weight to the scale output one will activate above its setpoint and deactivate below its setpoint The same is true for the other two setpoints When activated each output s annunciator will light on the display 8 As weight is removed the displayed weight will remain unchanged due to being in peak mode but the OP annunciators will go out as each cutoff is reached Model E1070 Indicator User s Manual Communications The default serial port param eters are 9600 baud 8 databits no parity and 1 stop bit Stop bits for the serial communication are preset to 1 stop bit This is not config urable The E1070 provides an RS 232 output for data transmission to a peripheral device Refer to the Service Manual for RS 232 interface connections If your indicator has a peripheral device connected from the gross net weighing mode press the PRINT key to transmit the selected output s The PRINT annunciator will illuminate while data is transmitted and the data configured to be printed will be output to the printer Print Format 1 for weighing applications G 1234 56 Ib lt CR gt lt L
2. 2236 626316 Email schemberberkel awtxglobal com Web site www averyweigh tronix com France Berkel S A 36 Avenue de l Europe 95335 Domont Cedex Tel 33 1 39 35 57 00 Fax 33 1 39 35 57 57 Email averyweigh tronix france awtxglobal com Web site www averyweigh tronix com Ireland Berkel Ireland Limited Western Industrial Estate Naas Road Dublin 12 Tel 353 1 4600088 Fax 353 1 4600096 Email info awtxglobal com Web site www averyweigh tronix com Italy Brevetti van Berkel S p A Via F Olgiati 12 20143 Milan Tel 39 2 81861 Fax 39 2 810945 Email info awtxglobal com Web site www averyweigh tronix com Sweden Berkel AB Fagelviksvagen 18 20 S 145 53 Norsborg Tel 46 8 534 701 50 Fax 46 8 534 701 69 Email infocenter berkel se Web site www averyweigh tronix com United Kingdom Avery Berkel Limited Foundry Lane Smethwick West Midlands England B66 2LP Tel 44 870 90 3434 Fax 44 121 224 8183 Email info awtxglobal com Web site www averyweigh tronix com Avery Berkel Consumables UK Tel 44 870 90 30108 Fax 44 870 90 00366 Emai info awtxglobal com Web site www averyweigh tronix com Americas Canada Industrial products Avery Weigh Tronix Canada ULC 217 Brunswick Boulevard Pointe Claire QC H9R 4R7 Canada Tel 1 514 695 0380 Toll free 1 800 561 9461 Fax 1 514 695 6820 Email sales weigh tronix ca Web site www weigh tronix ca Me
3. ESC key to escape a function or return to normal operation mode Use to access the password display for the User menu Press the ENTER key to accept displayed choices Use the numeric keypad to enter values 71319 OB 19203 DB Press and release the ON OFF key to turn the unit on Press and hold the ON OFF key until the unit turns off Model E1070 Indicator User s Manual 7 There are several annunciators around the edge of the display The illustra Annunciators tion below explains each one Checkweighing graph Custom Unit Kilogram Motion Pound Center of zero Gross weight Net weight Tare Print Bottom LED color SCOM Red a cell has been ghosted Check the ghost log Green asensorcomm error has occurred Check the error log Off Scale is functioning normally Network 1 or 2 Red A network error has occurred Check the network settings on the indicator and PLC and reboot the indicator Green The network connec tion has been established Amber The network is ready for a connection but no connection has been estab lished Output 1 Center of Zero Motion Gross Net Tare Print OP 1 OP 2 OP 3 PT Network amp SensorComm Status Accumulator Count Custom Unit KG LB Checkweigher Output 3 Output 2 Accumulator Count or Peak Weight Network amp SensorComm status Preset Tare Lights when weight on th
4. When the weight reaches the setpoint for ingredient 1 OP 1 annunciator light goes out OP2 annunciator lights and output 2 activates See note at left 4 Add weight to the scale When the weight reaches the setpoint for ingredient 2 OP2 annunciator light goes out OP3 annunciator lights and output 3 activates See note at left 5 Add weight to the scale When the weight reaches the setpoint for ingredient 3 OP3 annunciator light goes out and output 3 deactivates 6 Empty the scale and repeat steps 1 5 for the next batch Model E1070 Indicator User s Manual Manual Batching by Percentage Following is an example of batching for a recipe set as follows Batch type Percentage Batch mode Manual Basis Weight 1 With the indicator powered up and the scale empty zero the scale by pressing the ZERO key 0 is displayed 2 Press the F1 key The size of the last batch is displayed 3 Press the ENTER key to accept the batch size OR Key in a new batch size and press the ENTER key The OP1 annunciator lights and output 1 is activated 4 Add weight to the scale When the weight reaches the percentage of the batch size set in the recipe for ingredient 1 OP1 annunciator light goes out 5 Press the F1 key OP2 annunciator lights and output 2 activates 6 Add weight to the scale When the weight reaches the percentage of the batch size set in the recipe for ingredient 2 OP2 annunciator ligh
5. and press the PRINT key the display should show PASS If there is a problem the display will show FAIL Press the SELECT key after checking the port function PORTI is displayed Press the UNITS key PORT 2 is displayed Repeat the test from step 14 to check the port Press the SELECT key twice to exit the serial test SERIAL is displayed Press the SELECT key TEST is displayed Press the UNITS key AUDIT is displayed Model E1070 Indicator User s Manual 25 26 20 21 22 23 24 25 Press the PRINT key CFG is displayed This stands for the configuration audit counter Press the PRINT key to see the number of times the configuration has been altered on this indicator Press the SELECT key CFG is displayed Press the UNITS key CAL is displayed This stands for the calibration audit counter Press the PRINT key The number of times the indicator has been calibrated is dis played Press the ESC key twice The display returns to normal operation mode This completes the User menu Model E1070 Indicator User s Manual Model E1070 Indicator User s Manual 27 WORLDWIDE AVERY WEIGH TRONIX COMPANIES For information please contact your local Avery Weigh Tronix support center or one of the addresses shown below Europe Austria Schember Berkel Ges m b H 2355 Wiener Neudorf Industriezentrum N S d Strasse 3 0bjekt 30 Tel 43 2236 626310 Fax 43
6. application active Applications are activated through a password protected menu See the Service Manual for instructions There are two types of sampling bulk and dribble These are selected in a password protected menu See the Service Manual for instructions Bulk sampling In this sampling method you place the specified number of items on the scale all at once in bulk and the scale automatically starts to calculate piece weight and then shows the count Dribble sampling In this sampling method you can count out the specified number of items onto the scale and when you are ready press the F1 key and the scale starts to calculate piece weight and then shows the count Each method is described below 1 In gross weight mode press the F1 key A numeric value is displayed This is the current sample size 2 Acceptthe current sample size by pressing ENTER OR Enter a new sample size see note at left and press ENTER Zeroin is briefly displayed This shows the indicator is zeroing itself Add is then displayed 3 Place the correct sample size on the scale all at the same time Busy is briefly displayed followed by one of two possible out comes a Ifthe sample met the minimum sample requirements and the weight is stable the display will show the correct number of parts on the scale and the green annunciator is lit b Ifthe sample size was not large enough or if the weight was unstable Abort is displayed and the
7. display returns to gross weight mode Repeat steps 1 3 using a larger sample size 4 Place the parts on the scale to be counted 5 You can accumulate the counts and track the number of transactions by pressing the PRINT key while in count mode See Displaying Count Information about displaying this information Model E1070 Indicator User s Manual 19 Dribble Sampling Displaying Count Information 20 In gross weight mode press the F1 key A numeric value is displayed This is the current sample size Accept the current sample size by pressing ENTER OR Enter a new sample size see note at left and press ENTER Zeroin is briefly displayed This shows the indicator is zeroing itself Add is then displayed Place the correct sample size on the scale and press the F1 key Busy is briefly displayed followed by one of two possible outcomes a Ifthe sample met the minimum sample requirements and the weight is stable the display will show the correct number of parts on the scale and the Count annunciator is lit b Ifthe sample size was not large enough or if the weight was unstable Abort is displayed and the display returns to gross weight mode Repeat steps 1 3 using a larger sample size Place the parts on the scale to be counted You can accumulate the counts and track the number of transactions by pressing the PRINT key while in count mode See Displaying Count Information below about displaying this informati
8. from the scale and press the SELECT key repeatedly istpress Net weight displayed 2nd press Tare weight displayed 3rd press Display toggles between showing ACCUM and gross total of all weighments 4th press Display toggles between showing ACCUM and net total of all weighments 5th press Display toggles between showing TOTAL and number of weighments 6th press Display returns to gross weigh mode You need the supervisor s password to clear the accumulator See the Service Manual for instructions Model E1070 Indicator User s Manual 11 Using Cutoffs in the Accumulator Application 12 If enabled you can use the cutoff trips function while in the accumulator application Cutoffs are enabled in a password protected menu See the Service Manual for instructions Follow these steps to set up to three cutoffs 1 With the indicator powered up press and hold the F1 key until OPI is displayed 2 Press the PRINT key The current value for OP1 is displayed 3 Press ENTER to accept this value OR Key in a value and press the ENTER key OPI is displayed 4 Scroll through all three outputs by using the TARE or UNITS key 5 Repeat steps 2 and 3 for each output 6 Press ESC key SAVE is displayed 7 Press ENTER to save the changes or ESC to abort the changes The unit returns to normal operation mode with the saved outputs active 8 As you apply weight to the scale output one will activat
9. Avery Weigh Tronix se TT Model E1070 Indicator User s Manual UNITED STATES This equipment has been tested and found to comply with the limits for a Class A digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own expense CANADA This digital apparatus does not exceed the Class A limits for radio noise emissions from digital apparatus set out in the Radio Interference Regulations of the Canadian Department of Communications Le present appareil numerique n emet pas de bruits radioelectriques depassant les limites applicables aux appareils numeriques de la Class A prescrites dans le Reglement sur le brouillage radioelectrique que edicte par le ministere des Communications du Canada EUROPEAN COUNTRIES WARNING This is a Class A product In a domestic environment this product may cause radio interference in which the user may be required to take adequate measures CAUTION Risk of electrical shock Do not remove c
10. F gt OR T 34 56 Ib lt CR gt lt LF gt OR N 1200 00 Ib lt CR gt lt LF gt Print Format 1 for counting application Count 12230 Print Format 1 for peak application 12230 Ib lt CR gt Error Messages The display represents M by nn so min becomes nnin mode becomes nnode etc The following are displays you may see if problems occur or if invalid operations are attempted with your indicator Display Description Over range weight Under range weight The unit cannot perform a function LANE j Displayed while a key is pressed when attempting to modify a sealed selection without edit privileges SERLEd Model E1070 Indicator User s Manual 23 Indicator Diagnostics The user menu lets you test various functions of the indicator The user Testing Indicator menu is shown in Figure 8 Instructions for using the menu are found below Functions Normal Operation Mode Press and hold ESC for 3 5 seconds PASS_ M TARE SELECT ZERO PRINT UNITS lt 1 Key in 111 and press ENTER z Test Audit About Adc Display Button Serial Software mV V Display Button Port 1 Port 2 version test test and revision Pass Fail Pass Fail Figure 8 User Menu 1 Access the User menu by pressing and holding the ESC key for 3 5 seconds PASS_ is displayed 2 Key in the User menu password 111 and press ENTER TEST is displayed 3 Pre
11. P Weigh Bar is a registered trademark of Avery Weigh Tronix and may be registered in certain jurisdictions ODVA Ethernet IP and DeviceNet are trademarks of ODVA PROFIBUS is a registered trademark of PROFIBUS International Avery Weigh Ironix se Avery Weigh Tronix Avery Weigh Tronix Canada ULC 1000 Armstrong Dr 217 Brunswick Boulevard Fairmont MN 56031 USA Pointe Claire QC H9R 4R7 Canada Telephone 507 238 4461 Telephone 514 695 0380 Facsimile 507 238 4195 Toll free 800 561 9461 e mail industrial weigh tronix com Facsimile 514 695 6820 www wtxweb com www weigh tronix ca
12. ach are explained below Limits Mode Enter the upper and lower limits for the item and the indicator will use those values to run the display See Figure 3 Lower limit A limit Each graduation 1 division Figure 3 Limits mode Sample Mode Place a correct weight product on the scale and press the F1 key The indicator will use this weight to run the display Upper and lower limits will automatically be 1 division above and below the target weight respectively Figure 4 shows how the graphic display works in Sample mode Each graduation is equal to 1 scale division The TARGET light stays lit if weight is 1 division of the target weight TARGET Lower limit Upper limit Each graduation 1 division Figure 4 Sample mode Directions for using each mode follows Model E1070 Indicator User s Manual Limits Mode Entering Uppe and Lower Limits This indicator has an 11 channel PLU Product Look Up memory To access a memory channel press a number from 0 to 10 then press the F1 key You can repeatedly press the SELECT key to view the items listed in the Sample and Limits modes on this page Performing a Checkweighment in Limits Mode Sample Mode Using Product to Set Target Weight Follow these steps to setup and use the checkweigher in limits mode 1 Empty the scale press the ZERO key to zero the display then press the F1 key Hi is displayed 2 Key in the upper weight limit using the numeric e
13. ach output is activated and deactivated automatically by the indicator The Basis of each ingredient can be weight time or pulse counts Weight If an ingredient basis is weight the output activates at the appropriate time and deactivates when the weight set in the recipe is reached Time If an ingredient basis is time the output activates for the time set in the recipe and then deactivates Counter If an ingredient basis is counts from a pulse counter the output activates for the value based on pulse count units set in the recipe and then deactivates The recipe values are set in a password protected menu You cannot change a recipe without using the password If the Batch Type is Per centage you can set the batch size but not change the percentage of each ingredient See the Service Manual for instructions on creating a recipe Examples of two batching routines are given on the next pages Model E1070 Indicator User s Manual 13 Auto Batching by Weight Each ingredient may have a built in delay time between deactivation of one ingredient and activation of the next 14 Following is an example of batching for a recipe set as follows Batch type Constant Batch mode Automatic Basis Weight 1 With the indicator powered up and the scale empty zero the scale by pressing the ZERO key Ois displayed 2 Press the F1 key The OP1 annunciator lights and output 1 is activated 3 Add weight to the scale
14. asily accessible Never use the unit without an appro priate earthground connection Any computer based system should have a separate grounded power circuit We recommend one for the Model E1070 The Model E1070 is a full function high connectivity indicator for most weighing applications and process control situations It is ideal for connected system weighing applications The display includes a multi segment fan graph for fast visual awareness for checkweighing Also the indicator can perform counting functions peak weight functions and act as a remote display The indicator also has 11 memory channels for storing data Communication ports allow connection to a many peripheral devices and to DeviceNet ProfiBus and EtherNet IP interfaces All this in a NEMA 6 4X rated enclosure Major sections of this manual are headed by titles in a black bar like ntro duction above Subheadings appear in the left column Instructions and text appear on the right side of the page Occasionally notes tips and special instructions appear in the left column Your indicator will be installed by a qualified Avery Weigh Tronix distributor They will make the required connections to your scale and peripheral devices 1 With the unit plugged in see note at left press and release the O switch to turn the indicator on 2 The indicator powers up in normal operation mode Model E1070 Indicator User s Manual 5 Front Panel The front
15. ay lit whenever an item s weight is within 1 division of the target weight You can repeatedly press the SELECT key to view the following from the gross weight display 1st press Net annunciator lights and net weight is displayed 2nd press Tare annunciator lights and tare weight is displayed 3rd press Display toggles between HI and the upper weight tolerance in the current unit of measure This will always be one division 4th press Display toggles between LO and the lower weight tolerance in the current unit of measure This will always be one division 5th press Display returns to gross weighing mode Model E1070 Indicator User s Manual 17 You can repeatedly press the SELECT key to view the items listed in the Sample and Limits modes on this page Using Cutoffs in Check weigher Application Standard Cutoffs Target Cutoffs 18 Performing a Checkweighment in Sample Mode 1 With your target weight set as described above place your item on the scale If the weight is correct Ois displayed and the TARGET annuncia tor lights If the weight varies from the target value upper or lower segments may be lit and the weight will show a plus or minus weight reading for the deviation from the target weight 2 Repeat step 1 for all products of this weight If enabled you can use the cutoff trips function while in the checkweigher application Cutoffs are enabled in a password protected menu See the Service Manua
16. cale output one will activate above its setpoint and deactivate below its setpoint The same is true for the other two setpoints When activated each output s annunciator will light on the display Model E1070 Indicator User s Manual 21 Peak Weighing Press the MODE key to scroll through the activated applica tions Press and hold the MODE key for 3 5 seconds to see the name of the currently active application Using Cutoffs MASE SET You can press the SELECT key or the ESC key to abort the process in step 3 22 This section applies if your indicator has the Peak application active Only the highest weight applied to the scale is displayed in the Peak applica tion A lit green LED indicates that peak weight is being displayed As a reminder that you are in peak mode a green annunciator is lit to the right of the weight display 1 Add weight to the scale Weight is displayed 2 Remove weight Peak weight is displayed 3 To clear the peak value be sure scale is empty and press the F1 key Ois displayed 4 Repeat steps 1 3 5 Press the SELECT key to cycle through Gross Tare Net and Peak If enabled you can use the cutoff trips function while in the peak applica tion Cutoffs are enabled in a password protected menu See the Service Manual for instructions Follow these steps to set up to three outputs 1 With the indicator powered up press and hold the F1 key until OPI is displayed
17. e above its setpoint and deactivate below its setpoint The same is true for the other two setpoints When activated each output s annunciator will light on the display Model E1070 Indicator User s Manual Batch Weighing Press the MODE key to scroll through the activated applica tions Press and hold the MODE key for 3 5 seconds to see the name of the currently active application This indicator has an 11 channel PLU Product Look Up memory To access a memory channel key in a number from 0 to 10 then press the F1 key Pulse count requires optional feature This section applies if your indicator has the batching application active The batching application has 11 recipes each with up to 8 ingredients In the recipe the following items are set Batch type can be by weight or a percentage Weight Batches are all the same size and the weight of each ingredient is predetermined by the recipe Percentage Batch size is chosen by the operator and each ingredi ent is determined by the percentage set in the recipe Batching mode can be Manual or Automatic The PLU recipe channel must be selected prior to a batching operation Manual If the recipe is set up for manual mode you press the F1 key to start the batch and you need to press the F1 key each time a setpoint is reached to activate the next ingredient output Automatic If the recipe is set up for automatic mode you press the F1 key to start the batch and e
18. e menu See the Service Manual for instructions on changing applica tions This indicator has an 11 channel PLU Product Look Up memory To access a memory channel key in a number from 0 to 10 then press the F1 key The following information if present becomes active Channel Lower Limit ID Upper Limit Gross Accum Piece Weight Net Accum Cutoff Wt1 Count Accum Cutoff Wt2 Total Cutoff Wt3 Tare Value The accumulator application comes as the default application You can do gross weighments tare net weighments and accumulator functions Below are instructions for each To perform gross weighing power up the unit and follow these steps 1 Empty the scale and press ZERO key to zero the display Ois displayed 2 Place item to be weighed on the scale Weight is displayed To perform a net weighment power up the unit and follow these steps 1 Empty the scale and press ZERO key to zero the display Ois displayed 2 Place item to be tared on the scale Weight is displayed 3 Press the TARE key Ois displayed and the NET annunciator lights 4 Place material to be weighed on the scale Net weight of material is displayed 5 Repeatedly press the SELECT key to scroll through gross tare and net modes Remove the weight from the scale and press TARE to return to gross mode Model E1070 Indicator User s Manual Acummulator Weighing The Accumulator application comes as the default active a
19. e scale is within the zero range Lights during scale motion Goes out when scale is stable Lights when gross weight is displayed Lights when net weight is displayed Lights when tare weight is displayed Lights when print format sent through serial port Lights when output one is activated Lights when output two is activated Lights when output three is activated Lights when preset tare is active This is configurable to light to show status of the Net work 1 Network 2 or SensorComm See note at left Lights when an accumulation occurs and while in the count and peak applications Lights when a custom unit of measure is active Lights when kilograms is the active unit of measure Lights when pounds is the active unit of measure Lights when checkweighing application is active Model E1070 Indicator User s Manual Menu Mode User menu password is 111 You must key in the password within 10 seconds or the display returns to normal operation mode The display represents M by nn so min becomes nnin mode becomes nnode etc The E1070 has a User menu you use to do the following e See software information e See A to D mV V values e Do a display test e Do a button test e Test the serial ports e Audit the number of configurations and calibrations performed 1 Access the User menu by pressing and holding the ESC key for 3 5 seconds Release the key when PASS_ is displayed 2 Key in the User menu password 111 a
20. eration A7SISITISSIIZIIIA Model E1070 Indicator User s Manual 3 Specifications Power requirements e 85 265 Volts AC 0 3Amp maximum e 50 60 Hz Excitation e 5 volts DC e Supports up to eight 350 ohm weight sensors Analog signal input range e 60 mV Analog signal sensitivity e 0 2 pV V divisions minimum e 1 0 pV V divisions recommended Calibration 2 to 5 points stored Operational keys e Twenty two keys Tare Select Zero Print Units F1 Clear Mode Escape Enter On Off Decimal 0 9 numeric Operational annunciators e Center of Zero Motion Gross Net Tare e Under Target Over e Units of measure LB KG e Print OP1 OP2 OP3 Pt Tare Display e Six digit seven segment 0 8 inch high LED Display rate e Selectable 1 2 5 10 Analog to digital conversion rate e 100 times per second Unit of measure Pounds kilograms custom Capacity selections e 999 999 with decimal located from zero to five places Incremental selections e Multiples and sub multiples of 1 2 5 Programmable selections Zero range motion detection automatic zero tracking five point linearization Time and date RAM e Battery backed up real time clock and RAM standard Internal resolution e 53 687 100 counts per mV V per second Harmonizer digital filtering e Fully programmable to ignore noise and vibration co EtherNet IP ID ODVA Ethernet IPTM and DeviceNet are trademarks of ODVA PROFIBUS is a registered trademar
21. k of PROFIBUS International Standard inputs e Three logic level inputs for Zero Print Tare Units and F1 Standard outputs 10 100 Ethernet Modbus TCP TCP IP SMTP DHCP Ethernet IP e PROFIBUS DP e DeviceNet e Two serial ports e RS 232 422 485 SensorComm selectable e RS232 or 20mA current loop e Three cutoff outputs Serial Command Inputs Outputs e Programmable serial response to ASCII character input e SMA protocol Broadcast Self diagnostics e Display keys inputs outputs serial port A to D converter Circuitry protection RFI EMI and ESD protection Options e Analog output Pulse input e ControlNet e TIU3 Operating applications General weighing with accumulation Batching Counting Checkweighing Peak measurement Remote display Operating temperature e 14to 104 F 10 to 40 C approved e 40 to 140 F 40 to 60 C non legal e Up to 95 non condensing humidity Enclosure e Stainless steel NEMA 6 4X Dimensions e 9 25 W x 9 25 H x 4 5 D bracket e 9 75 W x 11 H x 7 D with mounting bracket Weight 8 5 lb 4 kg Agencies e NTEP CC 04 031 Class III IIIL 10 000 divisions e OIML pending e Canadian Weights and Measures pending e UL CUL CE marked without mounting 4 Model E1070 Indicator User s Manual Introduction About This Manual Setup and Power up Attention Plug the Model E1070 into properly grounded socket outlet of the correct voltage installed near the equipment and e
22. l for instructions Follow these steps to set up to three outputs 1 With the indicator powered up in normal checkweighing mode press and hold the F1 key until OPI is displayed 2 Press the PRINT key The current value for OP1 is displayed 3 Press ENTER to accept this value OR Key in a value and press the ENTER key OPI is displayed Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 3 for each output Press ESC key to exit the cutoffs setup As you apply weight to the scale output one will activate above its setpoint and deactivate below its setpoint The same is true for the other two setpoints When activated each output s annunciator will light on the display N DR If cutoffs are configured for Target mode in the Supervisor menu cutoffs will follow the limits and accept values This means there is no additional configuration required Model E1070 Indicator User s Manual Counting Press the MODE key to scroll through the activated applica tions Press and hold the MODE key for 3 5 seconds to see the name of the currently active application This indicator has an 11 channel PLU Product Look Up memory To access a memory channel key in a number from 0 to 10 then press the ENTER key Bulk Sampling The display is showing counts when the green annunciator on the right of the display is lit This section applies if your indicator has the counting
23. nd press ENTER Figure 2 shows a flowchart of the User menu items Use the keys shown in the box in Figure 2 to navigate through the menu and choose the items you want Normal Operation Mode Press and hold ESC for 3 5 seconds ia det 0 PASS _ Bl TARE ZERO Q UNITS gt Key in 111 and press ENTER i cre f cat About Adc Display Button Serial Software mVIV Display Button version test test FOA oa and revision Pass Fail Pass Fail Figure 2 User menu flowchart Specific instructions on the User menu appear in the section ndicator Diagnostics later in the manual Model E1070 Indicator User s Manual 9 Indicator Operations Press the MODE key to scroll through the activated applica tions Press and hold the MODE key for 3 5 seconds to see the name of the currently active application PLU Channels This indicator has an 11 channel PLU Product Look Up memory To access a memory channel press a number from 0 to 10 then press the F1 key Gross Weighing To change unit of measure press the UNITS key Tare Net Weighing To clear a tare weight remove all weight from the scale and press the TARE key 10 The E1070 comes equipped with several weighing applications e Accumulator weighing default setting e Batch weighing e Checkweighing e Counting e Peak weighing These different applications are activated using a password protected Servic
24. ntry procedure Press the ENTER key to accept the value or ESC to skip LO is displayed 3 Key inthe lower weight limit Press the ENTER key to accept the value or ESC to skip 4 Place item s on the scale and the display will show if the weight is over under or acceptable based on the limits you have set You can repeatedly press the SELECT key to view the following from the gross weight display 1st press Net annunciator lights and net weight is displayed 2nd press Tare annunciator lights and tare weight is displayed 3rd press Display toggles between HI and the upper weight tolerance in the current unit of measure 4th press Display toggles between LO and the lower weight tolerance in the current unit of measure 5th press Display returns to gross weighing mode 1 With your target weight set as described above place your item on the scale If the weight is within the upper and lower tolerances you set the TARGET annunciator lights If not the upper or lower segments will be lit 2 Repeat step 1 for all products of this weight Follow these steps to setup and use the checkweigher in sample mode 1 Zero the empty scale then place a sample of the correct weight on the scale Weight is displayed 2 Press the F1 key The weight is captured the display reads 0 net weight and your indicator is ready to use as a checkweigher The target weight will be the same as your sample item and the target will st
25. on You can scroll through the following information by using the SELECT key From count display press SELECT The display toggles between PIECE and the piece weight press SELECT The display toggles between CNT TOT and the count total press SELECT The display toggles between TOTAL and the number of accumulations done press SELECT The Gross annunciator lights and gross weight is displayed press SELECT The Net annunciator lights and net weight is displayed press SELECT The Tare annunciator lights and tare weight is dis played press SELECT The count display returns Model E1070 Indicator User s Manual Using Cutoffs in the Counting Application You can press the SELECT key or the ESC key to abort the process in step 3 If enabled you can use the cutoff trips function while in the counting application Cutoffs are enabled in a password protected menu See the Service Manual for instructions Follow these steps to set up to three outputs 1 SY Oh OY With the indicator powered up press and hold the F1 key until OPI is displayed Press the PRINT key The current value for OP1 is displayed Press ENTER to accept this value OR Key in a value and press the ENTER key OPI is displayed Scroll through all three outputs by using the left and right arrow keys Repeat steps 2 and 8 for each output Press ESC key to exit the cutoffs setup As you apply weight to the s
26. over No user service able parts inside Refer servicing to qualified service personnel Avery Weigh Tronix reserves the right to change specifications at any time 09 09 04 E1070_U P65 PN 43036 0016A e1 Printed in USA LEL e ELE xo O51 53 nilo 4 Wbbm 5 AbOUE This PN tinted ee clare to 5 Setup and Perni 5 Font Panel eaae L iti 6 KEYS dille 6 Amicis lana 6 Menu Mode slide 7 lndicat r Operations sssusa vel ae Jt ee ceed oe ane cece E E E ankaii 8 PEU CHANNELS een loi 8 Gross Weighing ue ear 8 Tare Net Weighing ce ieri 8 Accumulator Weighig cca ile 9 Using Cutoffs in the Accumulator Application 10 Baten AVSIGRING stride 13 Auto Batching Olanda 14 Manual Batching by Percentage i 15 Checkweighing aiar 16 Performing a Checkweighment ssaa 17 Using Cutoffs in Checkweigher Application 18 Old 19 Dios amp loi 20 Displaying Count Information allen 20 Using Cutoffs in the Counting Application 21 EE RR A 22 Using CUNS een ro nee eer pemne ee ere 22 ComMmMmuNICationsS i ccsectcosiad ctse ntejomontdienmisnsdennnenedennten celere oe 23 EftoMMEssSages lille 23 Indicator DIAG MO SWS iii 24 Testing IndieatofFUAcIoisgReR aa 24 IMPORTANT SILLLLILALILLI A This equipment must be routinely checked for proper operation and calibration f Application and usage will determine the frequency of calibration required for safe op
27. panel shown in Figure 1 consists of the keys and display Avery Weigh Tronix TARE SELECT ZERO PRINT UNITS Figure 1 E1070 front panel The functions of the keys on the front panel are listed below Keys HD Press the TARE key to perform a tare function Also acts as a TARE Never press a key with any left arrow key when in the User menu thing but your finger Damage to the overlay may result if sharp or rough objects are used Press the SELECT key to toggle between Gross Tare Net Count Gross Accumulator Net Accumulator Transaction Counter Piece Weight and Peak Dependent on the current application Also acts as an up arrow key when in the User menu Press the ZERO key to zero the display Press the PRINT key to send information to a peripheral device through the Comm port Also acts as a down arrow key when in the User menu U a zZ i Press the UNITS key to scroll through the available units of measure while in normal operating mode Also acts as a right UNITS arrow key when in the User menu 6 Model E1070 Indicator User s Manual Press the F1 key to select application specific choices Press and hold to access the cutoffs trips function Also used to access PLU memory channels Press the C CE key to clear entries Press the MODE key to scroll through the activated applica tions Press and hold for 3 5 seconds to see the name of the currently active application Press the
28. pplication in the E1070 You can use tare net weighing with the accumulator applica tion The accumulator stores both gross and net totals for later recall You must remove all weight from the scale to scroll through the items listed at right With weight on the scale repeatedly pressing the SELECT key will only show the gross net and tare values Press the MODE key to scroll through the activated applica tions Press and hold for 3 5 seconds to see the name of the currently active application The accumulator is memory that collects individual weighments gross and net and stores the totals These totals can be recalled at any time The number of weighments included in the totals can be displayed and all information can be reviewed and deleted To use the accumulator power up the unit and follow these steps 1 Empty the scale and press ZERO key to zero the display Ois displayed 2 Place item on the scale Weight is displayed 3 Press the F1 or PRINT key to add weight to the accumulator Pressing the PRINT key also prints the default print format A circle annunciator lights briefly on the right side of the display to show the weight was accumulated 4 Remove weight from the scale Weight must return to zero before another accumulation can be recorded 5 Repeat 2 through 4 for each weighment you want to accumulate 6 To review the accumulator total and the number of weighments remove all weight
29. ss the PRINT key ABOUT is displayed Press the PRINT key then the UNITS key to view the part number and revision level for the software found in your indicator Press SELECT key to return to ABOUT 4 Press the UNITS key ADC is displayed This is the mV V output of the connected analog scale 5 Press the PRINT key The mV V value is displayed This value should increase as weight is applied to the scale 24 Model E1070 Indicator User s Manual 10 11 12 13 14 15 16 17 18 19 Press the SELECT key ADC is displayed Press the UNITS key DISP is displayed This is the display test item Press the PRINT key to perform a dynamic test of the display All parts of the display flash Press the ESC key to stop the test The display flashes a couple more times and then DISP is shown Press the UNITS key BUTTON is displayed This is the button test item Press the PRINT key to perform a button test Each key you press will be reflected on the display screen to confirm the button is functioning correctly The ESC key is excluded from this test It is used to stop the testing and return to the menu item Press ESC key to stop the button test BUTTON is displayed Press the UNITS key SERIAL is displayed This is the serial test item Press the PRINT key to access the serial test PORTI is displayed If you jumper the transmit and receive lines on the serial port
30. t goes out 7 Press the F1 key OP3 annunciator lights and output 3 activates 8 Add weight to the scale When the weight reaches the percentage of the batch size set in the recipe for ingredient 3 OP3 annunciator light goes out and output 3 deactivates 9 Empty the scale and repeat steps 1 8 for the next batch Model E1070 Indicator User s Manual 15 Checkweighing The smallest orange segment of the fan graph shown in Figure 3 will be lit when in the checkweighing mode as a reminder that this application is active The graph is based off of net weight so if a tare is active only the net weight is considered for checkweighing If there is no tare gross weight is used as the basis for the graph Press the MODE key to scroll through the activated applica tions Press and hold the MODE key for 3 5 seconds to see the name of the currently active application 16 This section applies if your indicator has the checkweighing application active Applications are activated through a password protected menu See the Service Manual for instructions Checkweighing allows a quick visual check of the acceptability or unaccept ability of an item s weight You set your target weight in one of two ways It depends on how your indicator is configured The choice is made in the password protected Supervisor menu which is explained in the Service Manual Your unit will be configured with limits mode or sample mode E
31. xico Constructa de Basculas S A de C V Norte 59 No 880 B Local B Col Industrial Vallejo 02300 Mexico DF Tel 52 5 36 84033 Fax 52 5 58 70156 Email maluna berkel com mx Web site www averyweigh tronix com USA Industrial products Weigh Tronix Inc 1000 Armstrong Drive Fairmont MN 56031 USA Tel 1 507 238 4461 Fax 1 507 238 4195 Email industrial weigh tronix com Web site www averyweigh tronix com WORLDWIDE AVERY WEIGH TRONIX COMPANIES For information please contact your local Avery Weigh Tronix support center or one of the addresses shown below Retail products Avery Berkel North America 1758 Genesis Drive Suite A LaPorte Indiana 46350 Tel 1 800 237 1886 Fax 1 219 325 9587 Web site www averyweigh tronix com Africa Kenya Avery Kenya Limited Factory Street P O Box 30417 00100 Nairobi Tel 254 2 559004 Fax 254 2 543956 Email avery swiftkenya com Web site www averyweigh tronix com Asia and Pacific India Avery India Limited Ballabgarh Works Plot Nos 50 59 Sector 25 Ballabgarh Haryana Tel 91 129 223 4625 Fax 91 129 223 2557 Email stomar averyindia net Web site www averyweigh tronix com Malaysia Avery Malaysia Sdn Bhd No 8A Jalan 213 46050 Petaling Jaya Selangor Tel 60 3 7781 4344 Fax 60 3 7781 5623 Email adm avery po my Web site www averyweigh tronix com 30 Model E1070 Indicator User s Manual DeviceNet EtherNet I
Download Pdf Manuals
Related Search
Related Contents
E-style枠 親子開きドア XM-124 Dynamisches Standard-Messmodul Installationsanleitung Declaración Por favor, lea el manual del usuario con el - Fc Logic Wind - VDO Marine capa cd 2004.cdr - Câmara dos Deputados PROFIBUS and PROFINET for Grundfos MP 204 adt 1 68 adt 1 68 digital pressure gauge Copyright © All rights reserved.