Home
CO-200 - Allegion
Contents
1. 1 Press and hold the Schlage button while presenting a credential and the credential card is not accepted 2 This credential becomes the master construction credential the lock has either and is used to program construction access been programmed or 3 The Schlage button will blink green on the left and right as already has a master confirmation construction credential After you have created the master construction credential you If the master can then use that card to add construction access mode user construction credential credentials cannot be located or to The master construction credential will not grant put the lock back into access It is used only to add additional credentials construction access mode reset the lock to Add construction access mode user credentials locks factory settings See with card readers Reset to factory defaults 1 Present the master construction credential to the lock on page 11 for more The Schlage button will light information 2 Present the user credential to be added within twenty 20 seconds The user credential will be added to the lock database Credentials added using the master construction credential will have normal 24 7 access Cancel construction access mode Construction access mode may be cancelled by one of the following methods e load a door file using the SUS reset the lock to factory settings see Reset to factory defaults on page 11 for more information W
2. M Y amp E ee i PPIN Credential sisanne New PIN E between each H ew Car step add another credential OR E to finish Programming Code OR Programming Card Wait for G GEE Delete Credential Credential PIN to stop flashing delete another between each credential OR to finish step Programming Code OR Programming Card i Oe Wait for Change Relock Time Each button press adds to the total delay time Example 1 9 adds a 10 second delay 0 to disable beeper OR to enable beeper to stop flashing between each step to finish Programming Code F Wait for Disable Enable o G E to stop flashing Beeper 3 A between each step 1 Other lights may show before the final confirmation Wait for final confirmation before continuing to the next step 8 Schlage CO 200 user guide Wait for Function Press Present confirmation Programming Code OR Programming Card Wait for DOS A Change PIN Length DH to stop flashing Press a OR for desired PIN length between each a step to finish 1 Other lights may show before the final confirmation Wait for final confirmation before continuing to the next step Error codes All error codes are indicated on the Schlage button by a solid red LED anda blinking green LED The number of green blinks indicates the error code Number of green blin
3. Programming Card 3 G o Wait for Add Toggle O80 soe Credential jotetaiswudeasateassvesevannacedta pNew PIN between each for PIN only OR New Card step add another credential OR to finish Programming Code OR Programming Card 3 E Wait for Add Toggle PIN OFOROKE ae Credential tienen New PIN between each i New Card step add another credential OR s to finish 1 Other lights may show before the final confirmation Wait for final confirmation before continuing to the next step N Wait for Function Press Present confirmation Programming Code OR Programming Card DA Wait for Add Freeze M Emm Credential New PIN to stop flashing esresessesesoseecoseseoseessseese a between each for PIN only OR New Card step add another credential OR E to finish Programming Code OR Programming Card g BOS T Wait for Add Freeze PIN E M w E Credential N PIN to stop Nashing pepelape de iieorteudien gt oul i L between each i ew Ah step add another credential OR s to finish Programming Code OR Programming Card FH Wait for Add Pass Through M Y gt 8 Credential eee New PIN between each for PIN only OR New Card step add another credential OR to finish Programming Code OR Programming Card 3 3 E Wait for Add Pass Through 3
4. If DPS is used then opening door will also release privacy If a mortise deadbolt is used then retracting the deadbolt will also release privacy 13 Troubleshooting Problem The lock beeper does not sound and the keypad does not light when the Schlage button is pressed Possible cause The beeper may be turned off The battery or wired power may be improperly connected The batteries may be inserted with incorrect polarity The reader may not be properly seated into the front escutcheon The reader connector may have bent pins The through door cable may not be properly plugged in Solution Use manual programming or the SUS to enable the beeper see Disable Enable Beeper on page 8 or the SUS user guide for more information Check that the battery or wired power is connected correctly Check that the batteries are inserted in the correct polarity Check that the reader is fully seated into the front escutcheon Check that there are no bent pins in the reader connector Check that the through door cable is plugged in correctly The red wire should be on the left and not pinched in the door Refer to the installation instructions that came with the CO 200 lock or this user guide for details on the above mentioned procedures The connection with the SUS is not successful The Schlage button is always on solid green The triangles on the outside lock assembly cy
5. T P516 271 CO 200 Offline lock user guide Instructions for CO Series offline locks Para el idioma espa ol navegue hacia www schlage com support Pour la portion fran aise veuillez consulter le site www schlage com support OVEMNIE Peer A E REA C A eE cerrtrr eye cer herr tenereree A AE rere rivet creer E AE 3 Getting Started aaisen e a wie Ginn Adina nana 4 Schlage Utility Software SUS sssini eisino 160006060 see cc cescedactebanee eee 4 Construction access MOde ai satscisecsssczecedscaeadscgeaasegnasagancacanaechcenya caadadanascapassaeaesheaasepeanaede 5 Create the master construction credential locks with card readers 20 Add construction access mode user credentials locks with card readers avo Cancel construction access Mode ccceceeeeeeeeeeeeeeeeeeceeeeeeeaeeseeeeeeeeeseeees 5 LOCKS With KOYPadS size ccessicersscuescastensvetanasteawisesvaina ee coves decatnaees enccs sua Ger esecast E a 5 Manual lock programming sev 2sscssscteschcesstesseviccs m ERR GERS dda 6 Credential types z ocismaciccacacicoecccorm oriana aasa a E aeeai aiaa Programming legend 3a Manual Programming Command S asmina ana nn 7 Eron COGS is see A P REE A N E R E 9 TestlockoperatiOMh z v 2rbass trant MechanicalhMteStz 2 52r20222250520852220822220m2 EEES ENTE Test in factory default mode Test in normal Operation Mode csssssdsssiccctincics 200660200 ieedecaddeeaeesgdeaneedecececsicededa
6. US user guide for details on the above mentioned procedures 14 Schlage CO 200 user guide Problem Possible cause Solution The LEDs and The reader is not the The lock must be installed with the beeper indicate an original reader matched original reader that came with the lock incompatible reader with the lock at the 2 red blinks and 2 factory beeps with each card or key press or 5 red blinks and 5 beeps on power up 15 FCC Statements Allegion Agency Statements Compliance Statement Part 15 19 This device complies with Part 15 of the FCC Rules Operation is subject to the following two conditions 1 This device may not cause harmful interference and 2 This device must accept any interference received including interference that may cause undesired operation Warning Part 15 21 Changes or modifications not expressly approved by the party responsible for compliance could void the user s authority to operate the equipment FCC Interference Statement Part 15 105 b This equipment has been tested and found to comply with the limits for a Class B digital device pursuant to Part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference in a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio
7. anical and electronic operation See Test lock operation on page 10 for more information When ready to set up for normal use remove factory default security settings then program the user credentials See Manual lock programming on page 6 for more information Consult the Schlage Utility Software SUS user guide for information about configuring the lock Familiarize yourself with the information in this guide Save this user guide for future reference Schlage Utility Software SUS The Schlage Utility Software is used for programming and setup only The Schlage Utility Software SUS is used to configure locks The SUS configures lock functions that cannot be configured with manual programming and is used to transfer data files between the access control software and locks For more information about the SUS see the SUS user guide 4 Schlage CO 200 user guide Construction access mode Construction access mode is used to allow access before the lock has been programmed and for testing purposes vip e Enabled by default Use the same master The lock will remain in construction access mode until the construction credential mode is cancelled as described below for all the locks in the e No audits are captured while lock is in construction access facility mode If you present the first card to a new lock to create the Create the master construction credential locks with card readers master construction
8. communications However there is no guarantee that interference will not occur in a particular installation If this equipment does cause harmful interference to radio or television reception which can be determined by turning the equipment off and on the user is encouraged to try to correct the interference by one of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help RF Exposure Statement To comply with FCC IC RF exposure requirements for mobile transmitting devices this transmitter should only be used or installed at locations where there is at least 20 cm separation distance between the antenna and all persons Section 7 1 5 of RSS GEN Operation is subject to the following two conditions 1 This device may not cause interference and 2 This device must accept any interference including interference that may cause undesired operation of the device lt Allegion 2014 vW Printed in U S A 1 877 671 7011 www allegion com us ALLEGION Fa 2 Re 1037124 Customer Service
9. de OR card unlock the lock Normal Use Normal Use PIN Unlocks the lock momentarily PIN 3 6 digits OR card PIN 3 6 digits AND card Toggle Changes the state of the lock from PIN 3 6 digits OR card Toggle PIN locked to unlocked or vice versa unless PIN 3 6 digits AND card in a Freeze state Freeze Freezes the lock in the current state PIN 3 6 digits OR card Freeze PIN lock remains frozen until Freeze PIN 3 6 digits AND card credential is presented again Pass Through Pass Through PIN Unlocks a lock momentarily regardless PIN 3 6 digits OR card of state Overrides a lock in Freeze state PIN 3 6 digits AND card Programming legend Symbol Description Five digit code identical to programming Programming Code credential code listed in the Credential Types table Programming Card Programming Card identical to programming credential card listed in the Credential Types table TIP Use the same programming code for all locks in the facility Three to six digit code A PIN can be any of the PIN code types listed in the Credential Types PIN table A PIN entered before a card credential becomes the credential reference number E Asterisk key on the keypad o 9 Number keys on the keypad Schlage button 1 Programming codes such as 1 1 1 1 1 or 1 2 3 4 5 can be easily select
10. e when a credential is presented and the lock is in factory default mode and has no access programming 3 For locks with keypads enter the default PIN 13579 and to verify access The Schlage button will blink green a beep will sound and the door will unlock for the preset relock delay period After the relock delay period the lock will relock and the Schlage button will blink red If the lever retracts and holds the latch through the relock delay period then the Schlage button will light green until the lever is released Test in normal operation mode 1 Present a valid credential The Schlage button will blink green a beep will sound and the door will unlock for the preset lock delay period The lock will re lock after the lock delay period and the Schlage button will then blink red If the lever retracts and holds the latch through the relock delay period then the Schlage button will light green until the lever is released 2 If an invalid credential is presented the Schlage button will blink red a beep will sound and the door will not unlock Normal lock operation After credentials have been programmed present credentials to operate the lock as follows Credential type Action Credential Present credential to reader gt Green blink and access granted PIN Present credential oo PINI gt Within 5 seconds Green blink and Credential to reader gt ig Press gt access granted 1 Ifthe PIN i
11. ed by non authorized users and should not be used 6 Schlage CO 200 user guide Manual Programming Commands Commands are confirmed by five alternating green blinks of the Schlage button Programming mode will time out if no entry is made in 20 25 seconds Time out is indicated by red blinks of the Schlage button three left and nine right at the same time The right LED on the Schlage button will blink green to indicate an incorrect entry To interpret blink patterns refer to Error codes on page 9 Function Change Programming Code Change Programming Card Press Present Programming Code OR Programming Card D New Programming Code New Programming Code Programming Code OR Programming Card D New Programming Card Wait for confirmation Wait for to stop flashing between each step Wait for to stop flashing between each step Programming Code OR Programming Card Wait for Edi Add Normal Use G Credential T S E New PIN to stop flashing for PIN only OR New Card between each add another credential OR s to finish step Programming Code OR Programming Card F gt j 888 gt gt Wait for Add Normal Use 3 M W Ee PIN Credential tesa New PIN betweeneach i New Card step iadd another credential OR to finish Programming Code OR
12. etsninees 10 Normal lock operatios oides intinsa a iea 10 Reset to factory detault i c i ccicscusncatssasencsasesanasetanddaianssccaeaacetsuneseasactsaaasanasencastdeaasanecess 11 Level factory default reS t sist cacy cacisctiadtee ie aaar AR EAE NENE 11 L evel 2 factory default r esets cc cc8 aiwidan anita a N Ei 11 Batteries neiii enoaan asanarea arara TN A AEN NEETA AASE NENANA aa 12 To install or replace alkaline batteries ccccccciccciiiiiiiiiii iieis 12 Low battery INdICAUONS sscssisinceescstestetioccedsaacerssetucessecaseusiaasctadeacs easivsousned sveestaeetetaceds 13 Battery fall re TO OS sisca e a EO ainia aaie 13 ESDU E AEE EAE EAEE N EE EA Schlage button Optional Inside Push Button IPB Troublesho tiNg csiis asee aea a a aaa aa E a cei ca RE naa aa asi odvar 14 FCC Statements purini a ia e aa riani ia Peet octets 16 This product is compliant of UL 294 and ULC S319 standard This product s compliance would be invalidated through the use of any add on expansion memory or other module that has not yet been evaluated for compatibility for use with this UL Listed product in accordance with the requirements of the Standards UL 294 and ULC S319 This product has been evaluated for ULC S319 Class 2 Schlage CO 200 user guide Overview The Schlage CO 200 is an off line electronic lock in the CO Series product line This product is listed for UL294 and ULCS319 e The lock i
13. hen construction mode is cancelled the master construction credential and all other credentials added using the master construction credential will no longer function Locks with keypads In the factory default reset state offline locks with keypads with or without additional credentials have a default PIN of 13579 and which can be used for installation testing and construction access To test enter 13579 and The Schlage button will blink and the lock will unlock The default PIN is automatically deleted when a new programming credential is created construction credentials are created or the lock is programmed with the Schlage Utility Software SUS Manual lock programming Left LEDAN lt Right LED TIPS K N BR 22 O 0 lu N code of 97531 and of 13579 and FE WO Ov Ww The Schlage button has two different LEDs one on the left and one on the right All locks have a default programming All locks have a default normal use code When adding a card credential the 3 6 digit code PIN entered prior to presenting the card becomes the credential reference number This number can be used to delete a card without physically having the card Keep a log of all issued credential reference numbers and codes for future reference Credential types Credential type Programming Function Description Used to program the lock does not Five digit co
14. ks Error Code Description Computer programming error not complete Too long programming user code entered Programming code must be five 5 digits User code length cannot exceed six 6 digits Memory full too many codes Delete some codes Programming code cannot be deleted only changed Programming code entries do not match Programming code not changed Invalid command Invalid function code entered Code not found Code too short Programming code length must be five 5 digits User code minimum length is three 3 digits 9 Not a unique code 10 Manual programming not allowed Error code functions have not been verified by Underwriters Laboratories Inc NID AJA S N gt o Test lock operation If you encounter problems while performing any of the following tests review the installation guide and correct any problems Mechanical test 1 Rotate the inside lever or depress the push bar to open the door Operation should be smooth and the latch should retract 2 Insert the key into the keyway and rotate the key and the outside lever to open the door Operation should be smooth and the latch should retract The Schlage button will light solid green until the key is released and the latch is extended Test in factory default mode 1 For locks with a keypad press any number key The lock will beep and the Schlage button will blink red 2 The Schlage button will blink red twic
15. l battery installation or replacement refer to instructions at www schlage com support CAUTION Danger of explosion if batteries are incorrectly replaced Replace only with the same or equivalent type Dispose of used batteries according to the manufacturer s instructions This product has been evaluated for ULC S319 compliance with Duracell Procell PC1500 AA alkaline batteries and Panasonic CR2025 lithium coin cell For installations requiring ULC S319 these battery models should be used 12 CY MS amp MD Schlage CO 200 user guide Low battery indications Condition Indicator Solution Batteries low After credential is presented Replace batteries immediately to 9 red blinks of Schlage button Left avoid battery failure Lock is intended AA batteries Right Coin Cell to operate for 500 cycles in low battery then normal indicator battery condition Battery Failure No LED or beeps and valid Replace batteries immediately configured by credentials do not grant access Mechanical override key must be used SUS to unlock the lock Battery failure modes The battery failure mode is set using the SUS See the SUS user guide for more information Mode Description Fail As ls default Lock remains in current state until batteries are replaced Fail Unlocked Lock unlocks and remains unlocked until batteries are replaced Fail Locked Lock locks and remains locked
16. lindrical and mortise locks only may not be properly aligned The triangles on the outside lock assembly may not be properly aligned cylindrical and mortise locks only Check the outside lock assembly cylindrical and mortise locks only The triangles on the back of the lock assembly must be properly aligned Refer to the installation instructions that came with the CO 200 lock for details Check the outside lock assembly cylindrical and mortise locks only The triangles on the back of the lock assembly must be properly aligned Refer to the installation instructions that came with the CO 200 lock The reader is not working The Smart card is not reading The magnetic swipe card is not reading correctly no beeps or blinks The through door cable may be pinched The Smart card default of the card reader may not be correct for the Smart card The Mag Track in Use default for all magnetic card credential readers is Track2 The magnetic swipe card data may be on Track1 or Track3 Check that the through door cable is not pinched Change the Smart card format using the SUS Select CO 200 Lock Properties Reader tab and Smart cards in use Use the SUS to change Mag Track in Use Select CO 200 Lock Properties Reader tab and MAG Card Track selection Refer to the installation instructions that came with the CO 200 lock or the S
17. o factory defaults If the mechanical key is not rotated within 10 seconds two beeps and two red blinks indicate timeout Level 2 factory default reset Level 2 factory default reset will delete all configurations and settings in the lock and the reader Reader configurations that will reset to factory default include keypad format magstripe reader track beeper on off and contactless card Days in Use counter and lock type configurations will not reset To complete Level 2 factory default reset repeat steps 2 through 4 within 10 seconds of the confirmation signals of level 1 factory default reset If more than 10 seconds pass after the confirmation signals of level 1 reset then level 1 reset must be repeated prior to performing level 2 reset To install or replace alkaline batteries 1 2 3 4 5 Battery voltage can be checked with the SUS Changing batteries does not affect any programmed data Remove the battery cover Remove the battery bracket Do not allow the battery pack to hang from the wires Install the new batteries install only new AA Alkaline batteries Make sure the batteries are installed in the correct orientation Reinstall the battery pack and battery bracket Reinstall the battery cover making sure the plug is to the right of the battery pack CY MS and MD locks Be careful not to pinch the battery wires when installing the battery cover For coin cel
18. s configured to operate as Classroom Storeroom function Optional Office or Privacy functions are available The lock is powered by four 4 AA batteries See Batteries on page 12 for more information Outside lever is normally locked Inside lever always allows egress e The lock maintains an audit trail of events in the normal operating mode e The lock is configured using the Schlage Utility Software SUS See Schlage Utility Software SUS on page 4 for more information RN Prox Sy Outside lt Schlage Button RN Keypad s Keypad Prox id ae Reader Reader Outside a Lever Ss Keyway Mag Swipe Keypad Reader Inside Thumbturn Battery Compartment Optional Inside Push Button DA L CO 200 CY CO 200 MD CO 200 993 CO 200 MS Inside Lever Getting Started Follow these steps when setting up a new lock i 2 3 6 T Install the lock See the installation guide that came with the lock or visit www schlage com support for more information Make sure the batteries are installed properly See Batteries on page 12 for more information Before programming the lock may be used in construction access mode See Construction access mode on page 5 for more information The lock should remain in construction access mode until you are ready to set up the rest of the system Test the lock for proper mech
19. s entered incorrectly press x to start over 2 The default PIN length is six 6 digits The key must be used as an ENTER key for PINs with fewer than six digits PIN length can be configured using the SUS so users do not have to press key 10 Schlage CO 200 user guide Reset to factory defaults All information in the lock will be deleted and reset to factory defaults The door must be locked not toggled open or in the middle of normal access before resetting to factory defaults Level 1 factory default reset Level 1 factory default reset will delete configurations and settings in the main controller in the lock Main controller configurations that will reset to factory default include programming and user codes Level 1 factory default reset will not reset configurations and settings in the reader Press and hold the Schlage button Wait for the lock to beep twice and two green blinks of the Schlage button indicating confirmation After confirmation signals release the Schlage button Rotate the mechanical key within 10 seconds and hold The Schlage button will light green Continue holding the key until confirmation signals are observed the Schlage button light will turn off one second and a one second beep will sound After confirmation signals release the mechanical key The Schlage button will light green for one second and a one second beep will sound to confirm reset t
20. until batteries are replaced LED reference Most LED indicators are configured with the SUS See SUS user guide for more information Schlage button Access denied 2 red blinks Access denied user outside time zone 4 red blinks Factory default reset One second solid green with one second beep Waiting for PIN 5 left red with right green blinks then solid right green Low battery indicator AA batteries 9 left red blinks Low battery indicator coin cell battery 9 right red blinks Momentary unsecured access 1 green blink then one red blink on relock USB active with no physical connection Left green blinking An incompatible reader is on the lock 2 red blinks and 2 beeps with each card or key press or 5 red blinks and 5 beeps on power up Optional Inside Push Button IPB Action Lights Office Mode Allows lock to toggle between locked normal and unlocked state Press IPB to lock 1 red blink Press IPB to unlock 1 green blink Privacy Mode Allows the lock to toggle between normal access and a state in which normal credentials are ignored With door closed press IPB to engage privacy 4 green blinks With door closed press IPB to release privacy 4 red blinks 1 Unlocking the lock with the IPB will cause the lock to remain unlocked until the IPB is depressed again 2 On locks configured with a mortise deadbolt throwing the deadbolt will also engage privacy 3
Download Pdf Manuals
Related Search
Related Contents
Mise en page 1 Polar FT80 User's Manual 添付文書:90916309-01A - Boston Scientific Kevin-pc\manual working\SBC\613\Em104-i613 Copyright © All rights reserved.
Failed to retrieve file