Home
SRV930 Manual - SR Instruments, Inc.
Contents
1. The low power microprocessor circuitry allows the SRV930 to derive its power from one 1 9 volt battery or for continuous operation the optional AC adaptor SRV930AC The animal s weight is displayed on a 4 2 digit LCD display INTENDED USE The SRV930 is designed for use as an animal weighing system for animals not exceeding 44 pounds Please read the following warnings to avoid injury to the animal or attendant WARNING DO NOT USE FOR ANIMAL TRANSPORT DO NOT EXCEED MAXIMUM LIMIT OF 44 LBS 20 KG USE HANDLES TO MOVE THE SCALE WHILE EMPTY MAINTENANCE and CLEANING The SRV930 scale s weighing surface is made from durable plastic Exercise caution when cleaning the display window as it is made of a clear plastic and can be scratched by abrasive cleaners Avoid getting liquids around the display area The display area is not moisture tight and excessive moisture could affect the electronic function of the scale Mild soap and water is recommended for general cleaning and disinfecting WARNING DO NOT use pressurized water or steam The scale system contains microprocessor circuitry and strain gauge sensors that may be adversely affected by exposure to such an environment SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale
2. The system is set in pounds MEMORY The MEMORY button is used to recall the weight of the patient in memory SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 8 of 14 BASIC SYSTEM OPERATION TURNING SYSTEM ON Make sure the scale is free and clear of any obstructions then press the TARE ON OFF button to turn the scale on When scale is ready 0 00 will be displayed REWEIGH NEXT USE To reweigh the same or different patient be sure the tray is free and clear of any objects Press the TARE ON OFF button to zero the scale When 0 00 is displayed the scale is ready for use Kg Lb FUNCTION Press the Kg Lb button to toggle between Ib oz Ib oz or kg displayed weight The scale will remain in the last mode used unless manually changed Example If the last weight recorded was in kilograms and the scale is shut down the weight mode will be in kilograms when the scale is turned back on TARE The tare function is used to subtract any additional items example receptacle from the patient s Net weight MEMORY Press the MEMORY button to store the last weight for recall if needed To view the last stored we
3. Inc warrants that all new equipment will be free from defects in material or workmanship under normal use and service for a period of two 2 years from the date of purchase by the original purchaser Normal wear and tear injury by natural forces user neglect and purposeful destruction are not covered by this warranty Warranty service must be performed by the factory or an authorized repair station Service provided on equipment returned to the factory or authorized repair station includes labor to replace defective parts Goods returned must be shipped with transportation and or broker charges prepaid SR Instruments Inc s obligation is limited to replacement of parts that have been so returned and are disclosed to SR Instruments Inc s satisfaction to be defective The provisions of this warranty clause are in lieu of all other watranties expressed or implied and of all other obligations or liabilities on SR Instruments Inc s part and it neither assumes nor authorizes any other person to assume for SR Instruments Inc any other liabilities in connection with the sale of said articles In no event shall SR Instruments Inc be liable for any subsequent or special damages Any misuse improper installation or tampering shall void this warranty DAMAGED SHIPMENTS Title passes to purchaser upon delivery to Transportation Company Any claims for shortage or damage should be filed with the delivery carrier by purchaser RETURN POLI
4. CY All products being returned to SR Instruments Inc require a Return Goods Authorization number RGA To receive an RGA call our Technical Service Team at 716 693 5977 or toll free in the USA and Canada at 800 654 6360 When inquiry is made please supply model and serial numbers purchase order if the scale was bought on contract and reason for return Generally deleted damaged and outdated merchandise will not be accepted for credit A minimum restocking charge of 15 will be assessed on return of current merchandise All returns are to be shipped FREIGHT PREPAID to SR Instruments Inc 600 Young Street Tonawanda NY 14150 RESTOCKING FEE e 15 fee for any scale that has been opened and used e 10 fee for any scale returned that has been ordered incorrectly or refused delivery with no model change e 5 fee if an error in ordering has been made and a different model exchanged e No fees will be charged if the scale is returned because of an error on the part of SR Instruments Inc e No returns accepted after 60 days SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 13 of 14 NOTES SR Instruments Inc 600 Young Street Tonawanda NY 14150 T
5. Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 1 of 14 SRScailes by SR Instruments Inc Model SRV930 Medium Capacity Counter Top Scale Operating and Service Manual Serial Numbers 1132 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 2 of 14 TABLE OF CONTENTS TABLE OF FIGURES vcinniasuseinsinnnennnisnininiiaionnisnndennnuiniennnenadene 2 PACKING CHECKLIST MODEL SRV930 e sessssesesescsscsossssesesossesosossesesossesossssesesossesosossssee 3 ASSEMBLY A A E T EE T E nin atada cado 3 ACCESSORIES saque aiii dd id dida a a a a ano 3 SYSTEM DESCRIPTION AND INTENDED USE esesessesesescssesossssesescssssosossesesosoesosossesesesossessss 4 MAINTENANCE AND CLEANING as cascavescsakcascivacsacs conseiscicentioncoancavsiasscenceasnsseninesdeetvensntecaacsads 4 STORAGE AND TRANSPORTATION ssesessosossesesesossesosossesescssesossssesesesoesosossesesescssosossesesessesesoss 5 ROCCE ECA ONG ana pas iai cedaessuadssiasunsecnsanneseksnacbameeanntatecascds is ind ada 6 BUTTON FUNCTIONS seia nara nana CRE caido dd cen tks so rs035 7 BASIC SYSTEM OPERATION vssssusessenscasc
6. Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 5 of 14 STORAGE and TRANSPORTATION STORAGE If storing this equipment for periods longer than three 3 months remove the battery To maintain proper operation of this instrumentation storage and transport conditions should not vary outside the following conditions Ambient Temperature 41 F to 95 F 5 C to 35 C TRANSPORTATION To transport the SRV930 from one location to another within the office use the handles to lift and carry If moving from inside to a mobile location SRI recommends using the soft sided carry case SRV930CC to protect the scale from outside elements SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 6 of 14 SPECIFICATIONS MAXIMUM WEIGHT CAPACITY 44 lb 704 oz 20 kg 24 in x 13 5 8 in x 2 2 in 62 cm x 33 cm x 5 cm Scale with handle PLATFORM SIZE Platform surface 19 1 2 in x 12 in 48 cm x 30 cm DISPLAY TYPE 1 0 LCD display with 4 4 active digits DISPLAY RESOLUTION 0 02 1b 0 5 oz 0 01 kg AUTO POWER DOWN Adjustable to 120 180 240 300 seconds and OFF MEMORY While active freezes dis
7. asedesnscdsenacnescccuccaxedssdnsadecnsnassoanesactantionusconcstecanteadeecaeceees 8 BATTERY REPLACEMENT assi Dai Diria add uia dia 8 CALIBRA TION ccsscetssssocnssseessscoressstectenseekeceisansdaeasastneatsdensssoceiased scbnceenseeanseniateodesacscnseanchedseasconnsesens 10 TROUBLESHOOTING cisssssisiassscccenigstascsnsssncniassansinnsoecsnaanouastangeecansonivecsuess auanoads okscassyecceanjennoaansiens 11 WARRANTY quand densa sincado da da a di Dun din anna dida 12 NOTES sscsceacssscenssennesnccenscuesturessandessssncwscsenacedsanessencoutanesciaweceasenencasaivensedsoenidenssenecedsousiieneaseusececsacsiess 13 TABLE OF FIGURES Figure 1 Battery Compartment Cover cscssssssssssssssssssssscssssssesssscssssscssssssssssssssssasesssasessneseees 3 Figure 2 Display Button Functions sscssssisscnsssvccedesunsssesdaniscesins casntsenciesssensisssdcnacosssveesaasssndeatesinstenss 7 Figure 3 Battery Compartment Cover e eesseessoecsoccssccesocescosecoeessccesocesocesoosesoesssecssocesocsscossssesssese 9 Figure 4 Calibration Button Display seseseeesooessoesssecssccesocescosesocesoccesccesocesoosssoeessecssocssocsscosesse 10 SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 3 o
8. el 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 14 of 14 SRScailes By SR Instruments Inc Precision amp Technology in Perfect Balance SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc
9. f 14 PACKING CHECKLIST Model SRV930 Medium Capacity Counter Top Scale 4 DESCRIPTION QUANTITY SCALE SYSTEM lea 9 VOLT BATTERY lea END CAPS 2 ea WARRANTY CARD lea MANUAL lea ASSEMBLY STEP 1 Unpack the Scale System and check parts against the PACKING CHECKLIST If there are any missing or damaged parts please call the Service Hotline 1 800 654 6360 STEP 2 Figure 1 Turn scale over Slide open Battery Compartment Cover Insert supplied 9 volt battery See BATTERY REPLACEMENT instructions Slide Battery Compartment Cover closed Turn scale over STEP 3 Install End Caps over handrails Battery Compartment Figure 1 Battery Compartment Cover ACCESSORIES Part Description SRV930CC Soft Sided Carry Case SRV930AC AC Adapter SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 4 of 14 SYSTEM DESCRIPTION AND INTENDED USE SYSTEM DESCRIPTION The SRV930 medium capacity counter top scale employs the latest in microprocessor and load cell technology to provide accurate and repeatable weight data Operated by one 1 9 volt battery the scale can be used in a fixed location or as a portable scale
10. ight in memory press the MEMORY button again to return to the original value NOTE MEMORY button will not store weight if weight is under two pounds one kilogram MEMORY will hold last stored weight until the memory is replaced with another stored memory The memory will not zero HOLD ARROW INDICATOR The HOLD arrow at the left bottom of the LCD display will first flash when weighing TURN SYSTEM OFF The SRV930 scale can be programmed to auto shut down at 120 180 240 or 300 seconds Pressing the TARE ON OFF button until the scale turns off will conserve on the battery life To change the auto shut down time press the TARE ON OFF button to turn the scale ON Press and hold the Kg Lb button until the display reads UNIT Press the Kg Lb button until the display indicates A OFF Continue on next page SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 9 of 14 BASIC SYSTEM OPERATION cont Press the MEMORY button once The display will indicate one of the following OFF 120 180 240 or 300 Toggle the Kg Lb to select the desired shut down time Once selected press the MEMORY bu
11. l sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 11 of 14 CAUTION The integrated circuits and semiconductors on the printed circuit boards may be damaged by electrostatic discharge ESD Be sure to use proper handling precautions at all times TROUBLESHOOTING SYMPTOM REASON CORRECTIVE ACTION Display reads LOW Battery needs replacing Display reads Err If the total weight exceeds the maximum capacity of the scale removed weight from the surface Memory will not Zero Memory will hold the last stored weight until it is replaced with another stored weight It will never Zero Memory will not store Memory will not store weight if weight is less than two 2 pounds or 0 9 kilograms For additional information or assistance phone our Service Hotline 1 800 654 6360 or e mail sri srinstruments com SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 12 of 14 WARRANTY TWO 2 YEAR LIMITED WARRANTY Each SRScailes system is manufactured with high quality components SR Instruments
12. ould perform this procedure Load cells have no user serviceable components and should not be tampered with for any reason Re calibration is generally not required but should be verified periodically to ensure accuracy The recommendation for calibration check is at least once every 12 months or as individual maintenance policy requires MEMORY Kg Lb TARE HOLD ON OFF Capacity 20kg x 0 01kg 44 Ib x 0 02 Ib m Figure 4 Calibration Button Display STEP 1 Press and hold the TARE ON OFF button display will read 8888 At the same time press the Kg Lb button three 3 times The display will then read the gravitational constant number or F FFF STEP 2 Press the TARE ON OFF button one 1 time The display will show and off set number STEP 3 Press the TARE ON OFF button The display will read 0 Scale is now in calibration mode STEP 4 Ensure scale is in kilograms mode STEP 5 Place 20 kg dead weight on the scale platform Display will show a span count between 2000 16000 STEP 6 Press TARE ON OFF button one 1 time Display will read CAL and then read 20 00 kg STEP 7 Remove the weight Display will read 0 00 Calibration is now complete Press the TARE ON OFF button to turn scale off SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com emai
13. play data and stores it in memory LAST WEIGHT RECALL MEMORY button recalls last stored weight AVERAGING Automatic digital filter POWER SUPPLY One 1 9 volt battery or optional AC DC adaptor CALIBRATION Calibrated to manufacturing specifications Normal operating conditions for this product OPERATING CONDITIONS Ambient Temperature Range 41 F to 95 F 5 C to 35 C Avoid exposure to high pressure water or steam Storage and transport conditions should not vary outside the following conditions TRANSPORT and STORAGE Ambient Temperature 41 F to 95 F 5 C to 35 C Remove batteries if storing longer than three 3 months SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 email sri srinstruments com Fax 716 693 5854 URL www srscales com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 7 of 14 BUTTON FUNCTIONS MEMORY Kg Lb TARE ON H _ OFF Capacity 20kg x 0 01kg 44 Ib x 0 02 Ib Es SSS mm o Figure 2 Display Button Functions The TARE ON OFF button is used to turn the scale on off to tare the TARE ON OFF weigh or to zero the display Holding the TARE ON OFF button for two seconds will manually shut down the scale Kg Lb The Kg Lb button is used to toggle between lb oz Ib oz or kg
14. tton to save The display will revert back to A OFF Press the Kg Lb button and toggle through features until the word END is displayed Press the MEMORY button to save your changes the display will return to normal mode BATTERY REPLACEMENT The low battery indicator will display on LCD display when battery s power is insufficient to operate the scale If available you can plug in the AC adaptor to continue operation STEP 1 While the tray is empty turn the scale over with the feet facing in the upward position STEP 2 Slide the Battery Compartment Cover open as the arrow on the cover indicates STEP 3 Unclip and remove current 9 volt battery and discard properly STEP 4 Replace with new 9 volt battery STEP 5 Replace Battery Compartment Cover STEP 6 Turn the scale to an upright position STEP 7 Press the TARE ON OFF button to confirm scale is operating Figure 3 Battery Compartment Cover Battery Compartment Cover SR Instruments Inc 600 Young Street Tonawanda NY 14150 Tel 716 693 5977 Fax 716 693 5854 URL www srscales com email sri srinstruments com Copyright 2014 SR Instruments Inc Model SRV930 Series Medium Capacity Counter Top Scale Operating and Service Manual S N 1132 Part No MANSRV930 141208 Page 10 of 14 CALIBRATION IMPORTANT This scale is factory calibrated and ready for use IMPORTANT CALIBRATION CHECK Qualified service personnel only sh
Download Pdf Manuals
Related Search
Related Contents
CORS-AIR ECF15 RC-18 RC-24 RC-30 RC Fortress HD0624DG Instructions / Assembly WooKong Multi Rotor Product Release Notes Kodak HERO 7.1 User's Manual Complete ECE 375 Manual - Oregon State University Philips Daily Collection HR1560 Examination Request System for the Clinical Radiology dept User manual IGNIJET 2008 Copyright © All rights reserved.