Home

Tektronix TDS7000 Series Digital Phosphor Oscilloscopes

image

Contents

1. to 90 relative humidity with a maximum wet bulb tem perature of 29 C at or below 60 C noncondensing Upper limit derated to 20 relative humidity at 60 C Altitude Operating 10 000 ft 3 048 m Nonoperating 40 000 ft 12 190 m Random Vibration Operating 0 00015 g2 Hz from 5 to 350 Hz 3 dB octave from 350 to 500 Hz 0 000105 g2 Hz at 500 Hz Overall level of 0 27 GRMS Nonoperating 0 0175 g2 Hz from 5 to 100 Hz 3 dB octave from 100 to 200 Hz 0 00875 g2 Hz from 200 to 350 Hz 3 dB octave from 350 to 500 Hz 0 006132 g2 Hz at 500 Hz Overall level of 2 28 GRMS Safety UL 3111 1 CSA 22 2 No 1010 1 EN61010 1 Digital Phospor Oscilloscopes TDS 7000 Series http dpo tektronix com Digital Phosphor Oscilloscopes gt TDS7000 Series gt Ordering Information TDS7054 500 MHz Digital Phosphor Oscilloscope TDS7104 1 Ghz Digital Phosphor Oscilloscope TDS7404 4 GHz Digital Phosphor Oscilloscope All models include Accessory pouch Front cover Mouse Probe Calibration and Deskew Fixture 067 0405 00 Quick Reference 020 2335 00 User Reference 071 0700 00 GPIB Programmer s Reference TDS 7000 Series Product Software CD ROM TDS 7000 Series operating system restoration CD ROM Performance verification procedure PDF file NIST MIL STD 45662A and IS09000 Calibration Certificate Power Cord TDS7054 also includes 4 P6139A 500 MHz 10x Passive Probes TDS7404 also
2. Negative Duty Cycle Period Frequency Delay Combination Area Cycle Area Phase Burst Width Histogram related Waveform count Hits in box Peak hits Median Maximum Minimum Peak to Peak Mean u Standard Deviation o 1 U 2 u 3 o Waveform Processing Math Algebraic Expressions Define extensive algebraic expressions including waveforms scalars and results of parametric measurements e g Integral Ch1 Mean Ch1 1 414 Arithmetic Add subtract multiply divide waveforms and scalars Calculus Integrate differentiate Frequency Domain Functions Spectral magnitude and phase real and imaginary spectra Vertical Units Magnitude Linear dB dBm Phase degrees radians Window Functions Rectangular Hamming Hanning Kaiser Bessel Blackman Harris Gaussian Flattop2 Tek Exponential Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com D Digital Phosphor Oscilloscopes gt TDS7000 Series Display Characteristics Display Type Liquid crystal active matrix color display Display Size 211 2 mm W x 158 4 mm H 264 mm 10 4 in diagonal Display Resolution 640 horizontal x 480 vertical pixels Waveform Styles Vectors Dots Intensified Samples Variable Persistence Infinite Persistence Computer System and Peripherals CPU Intel Celeron Processor 500 MHz PC System Memory 128 MB Hard Disk Drive Rear panel removable hard disk drive
3. gt 4 3 GB capacity Floppy Disk Drive Front panel 3 5 in floppy disk drive 1 44 MB capacity CD ROM Drive Rear panel CD ROM drive Mouse Logitech thumb wheel model included USB interface Keyboard Order 119 6297 00 USB interface Input Output Ports Probe Compensator Output Front panel BNC connec tor requires Probe Cal Deskew Fixture included for probe attachment Amplitude 1 V 1 0 into a 250 Q load fre quency 1 kHz 5 Analog Signal Output Amplitude Front panel BNC connector provides a buffered version of the signal that is attached to the Channel 3 input when Ch 3 is selected as trigger source 20 mV div 20 into a 1 MQ load 10 mV div 20 into a 50 Q load Analog Signal Output Bandwidth Typical TDS7054 TDS7104 100 MHz into a 50 Q load TDS7404 1 Ghz into a 50 Q load Auxiliary Output Levels Front panel BNC connector provides a TTL compatible polarity switchable pulse when the oscilloscope trigger Parallel Port IEEE 1284 DB 25 connector Audio Ports Miniature phone jacks for stereo microphone input and stereo line output USB Port Allows connection or disconnection of USB keyboard and or mouse while oscilloscope power is on Digital Phospor Oscilloscopes TDS 7000 Series http dpo tektronix com Keyboard Port PS 2 compatible Mouse Port PS 2 compatible LAN Port RJ 45 connector supports 10Base T and 100Base T Serial Port DB 9 COM1 port SVGA Video Po
4. to 1 div at 3 GHz 0 35 div DC to 50 MHz increasing to 1 div at 1 GHz 0 35 div DC to 50 MHz increasing to 1 div at 500 MHz External Auxiliary Input 250 mV from DC to 50 MHz increasing to 350 mV at 500 MHz 250 mV from DC to 50 MHz increasing to 500 mV at 100 MHz 400 mV from DC to 50 MHz increasing to 750 mV at 100 MHz Main Trigger Modes Auto Normal and Single Auto Normal and Single Auto Normal and Single Trigger Sequences Main Delayed by Time Delayed by Events All sequences can include separate horizontal delay after the trigger event to position the acquisition window in time Trigger Level Range Internal 12 divisions from 12 divisions from 12 divisions from center of screen center of screen center of screen External Auxiliary Input 8V 8V 8V Line fixed at 0 V fixed at 0 V fixed at 0 V Trigger Coupling DC AC attenuate lt 60 Hz HF Rej attenuate gt 30 kHz LF Rej attenuates lt 80 kHz Noise Reject reduce sensitivity Trigger Holdoff Range 250 ns minimum to 12 seconds maximum 250 ns minimum to 12 seconds maximum 250 ns minimum to 12 seconds maximum Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com Digital Phosphor Oscilloscopes gt TDS7000 Series Trigger Modes Edge Positive or negative slope on any channel or front panel auxiliary input Coupling includes DC AC noise reject HF reject and LF reject Glitc
5. 04 TDS7404 Timebase Range 200 ps div 40 s div 50 ps 10 s div Timebase Delay Time Range 16 ns to 250 s 16 ns to 250 s Channel to Channel Deskew Range 25 ns 25 ns Time Interval Accuracy 0 30 sample interval 15 ppm reading 0 15 sample rate 10 ppm reading Trigger J itter RMS 8 pSms_ typical 7 PSrus Long Term Sample Rate and Delay Time Accuracy 15 ppm over gt 1 ms interval 10 ppm over gt 1 ms interval O Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com Digital Phosphor Oscilloscopes gt TDS7000 Series Acquisition System TDS7054 TDS7104 TDS7404 Real time Sample Rates 1 channel max 5 GS s 10 GS s 20 GS s 2 channels max 5 GS s 5 GS s 10 GS s 3 4 channels max 2 5 GS s 2 5 GS s 5 GS s Equivalent time sample rate max 250 GS s 250 GS s 250 GS s Maximum record length per channel 400 k 1 ch 200 k 2 ch 100 k 4 ch 400 k 1 ch 200 k 2 ch 100 k 4 ch with standard memory with Memory Opt 1M 2 M 1 ch 1 M 2 ch 500 k 4 ch 2 M 1 ch 1 M 2 ch 500 k 4 ch with Memory Opt 2M 8 M 1 ch 4 M 2 ch 2 M 4 ch 8 M 1 ch 4 M 2 ch 2 M 4 ch with Memory Opt 3M 16 M 1 ch 8 M 2 ch 4 M 4 ch 16 M 1 ch 8 M 2 ch 4 M 4 ch with Memory Opt 4M 32 M 1 ch 16 M 2 ch 8 M 4 ch Maximum Duration at Highest Real time Resolution 1 ch TDS705
6. 4 TDS7104 TDS7404 Time Resolution single shot 200 ps 5 GS s 100 ps 10 GS s 50 ps 20 GS s Max Duration with Standard Memory 80 us 40 us 20 us Max Duration with Opt 1M 400 us 200 us 100 us Max Duration with Opt 2M 1 6 ms 800 ps 400 us Max Duration with Opt 3M 3 2 ms 1 6 ms 800 us Max Duration with Opt 4M 1 6 ms Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com Digital Phosphor Oscilloscopes gt TDS7000 Series Acquisition Modes TDS7054 TDS7104 TDS7404 FastAcg Acquisition FastAcq optimizes the instrument for analysis of dynamic signals and capture of infrequent events Maximum FastAcg Waveform Capture Rate gt 200 000 wfms sec gt 200 000 wfms sec gt 400 000 wfms sec Sample Acquire sampled values Acquire sampled values Acquire sampled values Peak Detect Captures narrow glitches at all real time sampling rates Minimum Peak Detect Pulse Width lt l ns lt l ns 400 ps Averaging From 2 to 10 000 waveforms included in average Envelope From 2 to 2x109 waveforms included in min max envelope Hi res Real time boxcar averaging reduces random noise and increases resolution FastFrame Acquisition Acquisition memory divided into segments maximum trigger rate 150 000 waveforms per second Time of arrival recorded with each event Trigger System TDS7054 TDS7104 TDS7404 Sensitivity Internal DC Coupled 0 35 div DC to 50 MHz increasing
7. Digital Phosphor Oscilloscopes gt TDS7000 Series z Performance Simplicity and Connectivity TDS7000 Series oscilloscopes are high perform ance solutions for verification debug and charac terization of sophisticated electronic designs The family features exceptional signal acquisition per formance operational simplicity and open connec tivity to the design environment Classic analog style controls a large touch sensitive display and graphical menus provide intuitive control Open access to the Windows operating system enables unprecedented customization and extensibility Superior Performance TDS7000 models range from 500 MHz to 4 GHz bandwidth with single shot sample rates to 20 GS s meeting demands of the latest high speed logic families and multi Gigabit communication standards Acquisition memory options from 2 to 32 Megasamples maximize the value of high sample rate and ensure that critical events are captured with fine detail High performance jitter analysis to 1 pSays is achieved through exceptional trigger and acquisition performance deep memory and applied software TDS7000 Series high bandwidth signal access solutions include the P7240 4 GHz 120 ps rise time active probe and the P7330 3 GHz 130 ps rise time differential probe Small form factors and a wide array of tip accessories ensure effective ness In addition the TDS7404 includes the TekConnect signal interconnect system This inter
8. M TDS7M23 TDS7M24 From Opt 3M TDS7M34 Digital Phospor Oscilloscopes TDS 7000 Series http dpo tektronix com Digital Phosphor Oscilloscopes gt TDS7000 Series Instrument Options Available where indicated by x TDS7054 TDS7104 TDS7404 Acquisition Memory Options 1M 2 Msamples max 500 ksamples ch x X x 2M 8 Msamples max 2 Msamples ch X X X 3M 16 Msamples max 4 Msamples ch x x X 4M 32 Msamples max 8 Msamples ch xX Mounting Options 1K K4000 Scope cart X X X 1R Rackmount kit X X X Software Options ji TDS IT2 Jitter Analysis Software xX xX X 2 TDSDDM2 Disk Drive Analysis Software X X X Probe Options 30 No Probes X X X 33 Add 1 P6158 3 GHz 20x Low C Probe X 34 Add 1 P6247 1 0 GHz Differential Probe X 35 Add 1 P6243 1 0 GHz Active Probe X 36 Add 1 P6139A 500 MHz 10x Passive Probe x X 37 Add 1 P6245 1 5 GHz Active Probe X 39 Add 1 P6248 1 7 GHz Differential Probe X 51 Add 1 P7240 4 GHz Active Probe x 52 Add 1 P7330 3 GHz Differential Probe X Service Options D1 Calibration data report X X X c3 Additional 2 years of calibration x x X D3 Calibration data report for Option C3 x xX X R3 Additional 2 years of repair X X X Digital Phospor Oscilloscopes TDS 7000 Series http dpo tektronix com 1 Digital Phosphor Oscilloscopes gt TDS7000 Series For Further Information Tektronix maintains a comprehensive constantly e
9. ardware Bandwidth Limits 250 MHz or 20 MHz Input Coupling AC DC Gnd DC Gnd Input Impedance 1MQ 0 5 or 50 Q 1 50 Q 2 5 Input Sensitivity 1 MQ 1 mV div to 10 V div Input Sensitivity 50 Q 1 mV div to 1 V div 2 mV div to 1 V div Vertical Resolution 8 bits gt 11 bits w averaging 8 bits gt 11 bits w averaging Max Input Voltage 1 MQ 150 V CAT Derate at 20 dB decade to 9 Vus above 200 kHz Max Input Voltage 50 Q 5 Vans With peaks less than 30 Volts Determined by TekConnect accessory DC Gain Accuracy 1 00 1 00 Offset Range 1 mV div 100 mV div 1 V 101 mV div 1 V div 10 V 1 01 V div 10 V div 100 V 2 mV 50 mV div 0 5V 50 5 mV 99 5 mV 0 25V 100 mV 500 mV 5V 505 mV 1 V div_ 2 5 V Channel to Channel Isolation Any two channels at equal vertical scale settings gt 100 1 at 100 MHz and gt 30 1 at the rated bandwidth 2100 1 at 4 Ghz DC Measurement Accuracy Stated for average gt 16 waveforms 0 3 Reading Net Offset Offset Accuracy 0 06 div V div Net Offset Offset Position Volts div 1 0 Reading Net Offset Offset Accuracy 0 06 div V div Net Offset Offset Position Volts div Delta DC Measurement Accuracy Stated for average gt 16 waveforms 1 0 Reading 0 1 div V div 0 3 mV 1 0 Reading 0 1 div V div 0 3 mV Timebase System TDS7054 TDS71
10. com ze 150 9001 CE amp Copyright 2000 Tektronix Inc All rights reserved Tektronix products are covered by U S and foreign patents issued and pending Information in this publi cation supersedes that in all previously published material Specification and price change privileges reserved TEKTRONIX and TEK are registered trademarks of Tektronix Inc All other trade names referenced are the service marks trademarks or registered trademarks of their respective companies 4 00 HB PG 55W 13766 0 Tektronix 7
11. face replaces traditional BNC input connectors with a convenient positive locking interface suitable for higher system bandwidths P7000 Series probes are directly compatible with TekConnect signal interconnect system along with adapters that provide SMA BNC and N connections Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com gt Features amp Benefits 4 GHz 1GHz and 500 MHz bandwidth models Up to 20 GS s real time capture rate Up to 32 Megasamples memory depth gt 400 000 wfms second maximum waveform capture rate J itter measurements to 1PSauys Graphical user interface Control via classic direct controls touch sensitive color display or mouse Open Windows environment Built in networking gt Applications Verification debug and characterization of sophisticated designs J itter and timing analysis Spectral analysis Disk drive analysis Investigation of transient phenomena Tektronix 7 ONILNdWO9 WO94741 Digital Phosphor Oscilloscopes gt TDS7000 Series gt Figure 1 Digital Phosphor technology provides unprecedented waveform capture rate maxi mizing the probability of discovering hidden faults and revealing dynamic signal behavior Digital Phosphor Oscilloscopes Signal observation time is critical for successful dis covery of intermittent faults and characterization of complex dynamic signals TDS7000 Series Digital Phosphor Oscilloscopes i
12. for navigation or switch to a Windows menu bar Classic analog style controls provide instant access to the most frequently used functions while the large touch sensitive display provides intuitive menu operation Waveform positions cursor loca tions and trigger level can be directly dragged using the touch screen or a mouse A graphical drag box can be used to select a waveform area for zooming histogram analysis or measurement gating The USB interface allows a mouse keyboard and other peripherals to be added without powering off the instrument With this flexibility TDS7000 Series instruments readily adapt to a cart cluttered bench top shelf floor and other locations that otherwise make operation awkward D Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com gt Figure 3 Sophisticated analysis capabilities allow users to fully characterize and document design performance Application specific Extensions The TDS7000 family contains many extended fea tures to quantify and document signal characteris tics These features remain close at hand without cluttering the human interface Applied measure ment extensions can be installed to enhance TDS7000 capabilities Optional applications include jitter analysis and disk drive measurements These applications build on the precision signal acquisition performance of TDS7000 Series to address the need for application specific measurements to quickly quantif
13. h Trigger on or reject glitches of positive negative or either polarity Minimum glitch width is 1 0 ns with 200 ps resolution Width Trigger on width of positive or negative pulse either within or out of selectable time limits 1 ns to 1 s Runt Trigger on a pulse that crosses one threshold but fails to cross a second threshold before crossing the first again Optional time qualification Timeout Trigger on an event which remains high low or either for a specified time period selectable from 1 ns to 1 s with 200 ps resolution Transition Trigger on pulse edge rates that are faster or slower than specified Slope may be positive negative or either Setup Hold Trigger on violations of both setup time and hold time between clock and data present on any two input channels Pattern Trigger when pattern goes false or stays true for specified period of time Pattern AND OR NAND NOR specified for four input channels defined as HIGH LOW or Don t Care State Any logical pattern of channels 1 2 3 clocked by edge on channel 4 Trigger on rising or falling clock edge Trigger Delay by Time 16 ns to 250 seconds Trigger Delay by Events 1 to 10 000 000 Events Waveform Measurements Amplitude Amplitude High Low Maximum Minimum Peak to Peak Mean Cycle Mean RMS Cycle RMS Positive Overshoot Negative Overshoot Time Rise time Fall time Positive Width Negative Width Positive Duty Cycle
14. includes 4 TekConnect to SMA adapters TCA SMA Power Cord Options for all Models Opt Al Universal European power cord 220 V 50 Hz Opt A2 UK power cord 240 V 50 Hz Opt A3 Australia power cord 240 V 50 Hz Opt A5 Switzerland power cord 220 V 50 Hz Opt A99 No power cord Opt AC China power cord Recommended Accessories Keyboard USB interface Order 119 6297 00 Service Manual Order 071 0711 00 Transit Case Order 016 1522 00 TekConnect Adapters TCA SMA TekConnect to SMA Adapter TCA N TekConnect to N Adapter TCA BNC TekConnect to BNC Adapter Instrument Acquisitions Memory Upgrades Acquisition memory upgrades equivalent to Options 1M 4M can be ordered to extend instrument performance after initial purchase Users can install upgrades without opening the instru ment case or requiring on site service Order the appropriate TDS7Mxx kit from the following table according to current and intended configuration Software TDS IT2 J itter Analysis Software TDSDDM2 Disk Drive Analysis Software WSTRO Wavestar waveform capture and documentation software Cables GPIB Cable 1 m Order 012 0991 01 GPIB Cable 2 m Order 012 0991 00 RS 232 Cable Order 012 1298 00 Centronics Cable Order 012 1250 00 To Opt 1M To Opt 2M To Opt 3M To Opt 4M TDS7404 only From Standard Memory TDS7M01 TDS7M02 TDS7M03 TDS7M04 From Opt 1M TDS7M12 TDS7M13 TDS7M14 From Opt 2
15. n of networking enables Web based information brows ing e mail exchange printing and file sharing View the Windows Desktop on Separate Monitor TDS7000 can also be expanded with the addition of an external monitor With dual monitor mode enabled the instrument retains live scope displays while other applications such as publishing analysis or browsing tools reside on the external monitor Users can easily transfer images and waveform data from TDS7000 to the locally running applica tion or view Web based reference information while using the scope for design work Standard Interfaces The TDS7000 includes standard interfaces for con trol and peripheral expansion The GPIB command set shares a high degree of commonality with previ ous TDS 500 700 class instruments while increas ing hardware and software performance Both USB and PS 2 interfaces are included for mouse key board and other peripheral expansion USB offers the advantage of hot insertion and removal so devices can be added or removed without cycling power The TDS7000 also includes a LAN interface for network connection Digital Phospor Oscilloscopes TDS7000 Series http dpo tektronix com GB Digital Phosphor Oscilloscopes gt TDS7000 Series gt Characteristics Vertical System TDS7054 TDS7104 TDS7404 Input Channels 4 4 4 Analog Bandwidth 3 dB 500 MHz 1 Ghz 4 GHz Calculated Rise Time 10 mV div 1 V div 800 ps 400 ps 100 ps H
16. ncorporate 3rd generation DPX technology to enable maximum waveform cap ture rates of more than 400 000 waveforms per second This unprecedented performance allows users to fully visualize signal activity In trou bleshooting applications Digital Phosphor can save minutes hours or even days by quickly revealing the nature of faults so sophisticated trigger modes can be applied to isolate them Operational Simplicity The TDS7000 Series graphical user interface deliv ers sophisticated capability to advanced users with out intimidating occasional users The front panel includes a complete set of classic analog style con trols for most commonly used features For advanced use the combination of large 10 4 inch 264 mm touch sensitive display and graphical interface creates a highly visual environment with explicit illustration of instrument features The wave gt Figure 2 Extensive use of illustrations helps users locate advanced features quickly and apply them with confidence form display area remains visible even when dis playing control windows so changes in the wave form aren t missed when making selections or adjustments Context sensitive help supplements graphic control windows and encourages users to apply advanced capabilities to solve their problem The adaptable TDS7000 Series human interface readily supports any operating style and environ ment Users can select traditional instrument style buttons
17. rt DB 15 female connector connect a second monitor to use dual monitor display mode Supports Basic requirements of PC99 specifications GPIB Port IEEE 488 2 standard Scope VGA Video Port DB 15 female connector 31 6 kHz sync EIA RS 343A compliant connect to show the oscilloscope display including live waveforms on an external monitor or projector Power Source Power 100 240 Vays 10 50 60 Hz 115 Vans 10 400 Hz CAT Il lt 300 W 450 VA Digital Phosphor Oscilloscopes gt TDS7000 Series Physical Characteristics Benchtop Configuration Dimensions mm in Height 277 10 9 Width 455 17 9 Depth 425 16 75 Weight kg Ibs Net 18 39 Shipping 37 80 Rackmount Configuration Dimensions mm in Height 277 10 5 Width 502 19 75 Depth 486 19 125 Weight kg Ibs Net 19 41 Kit 5 6 12 25 Mechanical Cooling Required clearances in mm Top 0or gt 3 76 Bottom 0 0 Left side 3 76 Right side 3 76 Front 0 0 Rear 0 0 Environmental Temperature Operating 0 C to 50 C excluding floppy disk and CD ROM drives 10 C to 45 C including floppy disk and CD ROM drives Nonoperating 22 C to 60 C Humidity Operating 20 to 80 relative humidity with a maximum wet bulb temperature of 29 C at or below 50 C noncondensing Upper limit derated to 25 relative humidity at 50 C Nonoperating With no diskette in floppy disk drive 5
18. sions con sisting of waveform sources math functions meas urement values and scalars can be created easily using a calculator style editor This allows users to quickly transform raw waveform data into powerful information that is readily interpreted Enhanced Spectral Analysis The TDS7000 Series includes a unique spectrum analyzer style interface for performing frequency domain analysis Controls such as center frequency frequency span resolution bandwidth and reference level provide access to wide or narrow band fre quency phase and group delay information A gat ing function allows selection of only a portion of the time domain signal for analysis These controls allow users to focus on extracting spectral informa tion instead of confronting the idiosyncrasies of FFTs found in typical DSOs Complete Connectivity The TDS7000 Series includes open access to the Windows operating environment While the instrument remains a dedicated oscilloscope the ability to access the Windows desktop creates a powerful new tool Built in applications such as WordPad Paint and a web browser allow users to concurrently maintain lab notes while working with the instrument This saves time and eliminates error prone steps associated with transporting images for later report development Other applica tions such as Microsoft Excel MATLAB and MathCAD can be installed in the instrument to accomplish local signal analysis The installatio
19. xpanding collection of application notes technical briefs and other resources to help engineers working on the cutting edge of technology Please visit Resources For You on our Web site at www tektronix com D Digital Phospor Oscilloscopes TDS 7000 Series http dpo tektronix com Contact Tektronix ASEAN Countries 65 356 3900 Australia amp New Zealand 61 2 9888 0100 Austria Central Eastern Europe Greece Turkey Malta amp Cyprus 43 2236 8092 0 Belgium 32 2 715 89 70 Brazil and South America 55 11 3741 8360 Canada 1 800 661 5625 Denmark 45 44 850 700 Finland 358 9 4783 400 France amp North Africa 33 1 69 86 81 81 Germany 49 221 94 77 400 Hong Kong 852 2585 6688 India 91 80 2275577 Italy 39 2 25086 501 J apan Sony Tektronix Corporation 81 3 3448 3111 Mexico Central America amp Caribbean 52 5 666 6333 The Netherlands 31 23 56 95555 Norway 47 22 07 07 00 People s Republic of China 86 10 6235 1230 Republic of Korea 82 2 528 5299 South Africa 27 11 651 5222 Spain amp Portugal 34 91 372 6000 Sweden 46 8 477 65 00 Switzerland 41 41 729 36 40 Taiwan 886 2 2722 9622 United Kingdom amp Eire 44 0 1344 392000 USA 1 800 426 2200 For other areas contact Tektronix Inc Export Sales P O Box 500 M S 50 255 Beaverton Oregon 97077 0001 USA 1 503 627 6877 For the most up to date product information visit our web site at www tektronix
20. y device performance Intuitive Zooming TDS7000 acquired waveforms are always horizon tally fit into the display This big picture is retained for context while zoom is used to select areas of specific interest Waveform zoom can be directly controlled with knobs or the graphical user interface for intuitive interaction Digital Phosphor Oscilloscopes gt TDS7000 Series ee Dik es B Ceo AY eT gt Figure 4 Open access to the Windows desktop allows users to leverage standard tools for documentation analysis information browsing and communications Parametric Measurements The TDS7000 includes a complete parametric meas urement system for signal characterization Direct selection from a graphical palette makes locating choices simple Users can quickly reassign measure ments to a different waveform simplifying verifica tion tasks Split cursors make it easy to measure trace to trace timing characteristics Measurement Statistics can be gathered for deeper insight Measurement results are easily extracted for inclu sion in a document or analysis in a spreadsheet using the Windows clipboard or an Export function Powerful Math The TDS7000 Series allows user defined math expressions to be performed on waveform data giv ing them the opportunity to get on screen results in terms that they can define Common waveform math functions are provided at the touch of a button For advanced applications algebraic expres