Home
Lincoln Quicklub centralized and automatic
Contents
1. It s compact rugged easy to install and easy to use It has a long list of standard features including built in controller with LED display and keypad for easy programming system cycle monitoring a built in low level control and remote monitoring capability For those who thought the reduced downtime and improved safety of automated lubrication were out of reach and for those waiting for a cost effective system for their smaller machinery the reliable QLS 301 is the answer It s automatic lubrication made easy Same as QLS 401 except has spring loaded follower allowing for mounting P301 31211154 SSV6 12DC 30 10m Operating Voltage 12 and 24 VDC 120 and 230 VAC 50 60 Hz Operating Current 12 VDC 2 0A 24 VDC 1 0A 120 VAC 1 0A 230 VAC 0 5A Operating Temperature 10 to 158 F 25 to 70 C Number of Outlets 6 8 12 or 18 Reservoir Capacity 61 in 1 0L je 230 mm 9 05 in L ii mm 805 in 3 Protection NEMA 4 fl 1 Lubrication Cycle Time AC 20 min to 60 hours DC 4 min to 60 hours ai 5 Number of Cycles For VDC 1 to 5 cycles 22 ra For VAC SSV6 SSV8 1 to 3 cycles Qo Es For SSV12 SSV18 1 cycle EL ga s5 eJ i 5 i Timer Memory Indefinite f Maximum Operating Pressure 3000 psig 205 bar d Output per Outlet amp Cycle approx 0 012 in approx 0 2 cm Lubricant NLGI 2 grease 148 mm 6 74 in Weight 12 5 Ibs 5 7 kg NEL 9 mm gt
2. 274047 25 ft 7 6 m coil grease filled 274048 50 ft 15 2 m coil grease filled p 05 427 te re 062 1 575 274049 100 ft 30 5 m coil non grease filled grey 274050 500 ft 152 4 m coil non grease filled NOTE Burst pressure 2500 psi 172 bar LINCOLN 28 SKF Quicklub Lubrication Systems LINCOLN Fittings Adapters and Accessories aaa Sees Con Wwe Ls xe a ure s ner oo Pre Asa 28 Taper 49 APTE asa 2 Taper 90 NPTF_ 7 nner oo NPT Steel Tibe Model N Size 0 D x Wal O D x Wall Wendncb T odel No orking Pressure e OD Wal Length di 62175 7 020 25076m 4400 psig 300 bar Nylon IUE ISI Size Size OD xWal D x Wall Minimum Model No Working Pressure Bending Length Radius 62256 25 ft 7 6 m 62278 vs 026 100 ft 30 5 m 625 psig 42 5 bar 500 ft 152 m 500 ft 152 m m Grease Fittings Description 700506 7a NPT threaded straight leakproof fitting Plastic grease fitting cap Fittings Adapters and Installation Accessories Model No Description 10130 72 NPT male x NPT male nipple 10181 Ye NPT male x NPT female adapter 174 long e NPT male x female adapter 146 long 2 outlet NPT x NPT junction block 4 outlet NPT x 14 NPT junction block Junction Block NPT Ena gt D Bulkhead NPT male x NPT female x NPT female 10461
3. 14 145026328 chee mines xd 29 244048 27 27404T7 28 504 31606 3 26 LEA AA 29 244053 27 274048 28 51055 eem 29 14570 foe ete ee ole xen 29 244054 20 204049 paaa pba 28 51304 0 26 20012 Macias Ceres eee 29 244055 27 274050 28 519 30583 1 26 20024 i nee ba ena ii 29 244056 27 274062 28 30 519 34271 2 23 20026 8 ic eed 8 Pee See 29 24405T7 27 274097 31 519 34271 7 23 2002B x see px 29 244058 27 274098 2 2 aaa 31 519 34271 8 23 200292 eh iE ine eene 29 244201 30 274099 xp cee ee ee e 31 519 34339 3 23 20042 napaanak aag eae 30 244225 29 274149 bm 23 519 34339 4 23 20043 tek eas eed 30 244512 33 274238 ccc eee ees 28 532 31847 1 30 226 12508 5 30 244883 20 274239 hada debe 28 538 36763 1 24 226 13095 7 30 244884 27 274820 aaa 31 538 36763 4 24 226 14105 5 23 246002 28 27484T7 23 538 36763 5 24 236 10580 1 23 246322 24 276389
4. 31 544 320221 14 236 142619 23 246416 26 276390 2 26 6 2 26 31 544 32023 1 14 237 13381 2 23 247022 28 276391 31 544 32695 1 14 237 13381 3 23 247023 26 276395 28 544 32696 1 14 239406 bip ERR 33 247232 34 276407 29 30 544 32957 2 14 239408 rises na 33 247615 30 276409 24 549 342541 6 239410 4 ir Lor 33 247616 29 276424 30 549 34254 2 6 2939412 ee areca ee 33 249010 0 4 276831 29 549 342543 6 299418 0na E 33 249209 31 276634 31 549 342544 6 239499 cce Wk 26 249520 31 276635 31 549 34254 5 6 239857 o Ek Rx 26 249848 31 276693 31 549 34254 6 6 239959 ccs ck pnr Eus 26 249849 31 276954 vga 28 549 34254 7 6 241052 niis eR 24 249850 31 277057 24 549 34254 8 6 241053 ssepe 24 249851 31 277059 c se eg mana Wa 24 549 34254 9 6 241054 2 creen 31 249987 26 31 277226
5. 30 619 26651 3 5 241290 ri ees 26 272589 26 304 19165 1 30 619 26653 1 5 241293 2 pedes 26 272632 23 304 19166 1 30 619 26654 3 5 SKF 35 LINCOLN Quicklub Lubrication Systems LINCOLN Sees Numerical Index Model No Page No Model No Page No Model No Page No Model No Page No 619 26764 1 5 644 461744 11 80895 24 P311 31211154 19 619 26765 3 5 644 462781 8 81583 sesso 29 P311 31411110 20 619 26844 1 4 644 46278 3 8 85414 22 P311 31411154 19 619 26845 2 4 649 295351 6 85424 22 P31142611114 19 619 26848 1 5 649 295361 6 85425 22 P31142811114 19 619 26849 2 5 649 295371 6 85429 22 P311 61211154 19 619 271211 4 649 295381 6 1 87311 eek eee ehaee 32 P311 61411110 20 619 27122 1 4 649 295391 6 873121 aaa coo 32 P31161411154 19 619 27472 1 4 649 295401 TON 96412 ite wate ERR 32 P311 62611114 19 619 27474 1 4 649 295411 T 858301 aman kad kya 24 P311 6
6. 8 644 40867 1 13 650407654 20 94834LDL 13 644 40868 1 13 650 40768 3 20 94923 0 10 644 40869 1 13 650 40768 4 20 P30131211154 18 644 40870 1 13 650 40768 5 20 P301 31411110 20 644 40873 1 9 650 40915 8 16 P301 31411154 18 644 40987 2 9 650 40915 9 16 P30142611114 18 644 41040 1 13 655 287161 24 P301 42811114 18 644 46073 5 11 664 34005 5 23 P301 61211154 18 644 46073 6 11 664 34005 6 23 P301 61411154 18 644 46173 4 11 664 34195 9 24 P301 62611114 18 644 46173 5 11 664 36070 5 23 P301 62811114 18 644 46173 6 11 664 36070 6 23 P301 91211154 18 644 46173 7 11 66649 30 P301 91411154 18 644 46173 8 11 684862 26 P301 92611114 18 644 46174 2 11 700506 29 P301 92811114 18 LINCOLN 36 SKI A complete line of lubrication solutions and industrial pumping products Automatic lubrication Our automatic systems dispense measured amounts of lubricant at predetermined intervals S
7. 28 549 342551 6 241055 cz rena 31 252717 28 277307 30 600 26875 2 24 2411105 i RES 31 252807 26 31 303 16118 1 6 600 26876 2 8 PAVING ie sce venia pe RS 34 256276 24 303 161191 6 600 26876 2 24 241120 aa ba baka 31 270784 2 20 20 2505 nes 30 303 16120 1 6 600 26877 2 24 241124 aabang aes 34 270864 8 23 303 161211 6 600 28750 1 23 24 P HP E PER 34 270928 31 303 161221 6 600 29110 1 24 241129 2 teint are wes 34 271374 23 303 161231 6 600 29185 1 24 241132 dis 34 271924 pal eos 22 303 161241 6 600 29304 1 24 241133 a 34 271925 22 303 16125 1 6 619 26396 2 4 241238 28 30 271926 22 303 161261 6 619 26398 2 4 241286 s 28 271927 2 0 22 303 16127 1 6 619 26646 2 4 241287 soie 28 272394 27 28 303 17499 3 28 619 266482 4 241288 sss 28 272401 27 28 303 19346 2 28 619 266501 5 241289 s 28 272427 aa 28 304 191641
8. People capabilities and systems to save money and increase productivity Were the largest and most successful company in our field because we continu ally satisfy our customers with the world s best lubrication and pumping systems For more than a century companies have relied on our technical and quality leader ship our world class manufacturing and customer service and our vast network of distributors and support facilities Lincoln develops new products and systems at research and development facilities in the U S Germany and India that provide global and regional applica tion solutions We have solutions for large processing plants automotive manufacturing pulp and paper mills and food and beverage facilities Virtually every industrial professional involved in operations and maintenance can benefit from Lincoln systems On the road or in the field Lincoln pro tects heavy equipment used in mining construction agriculture and over the road trucking The world s leading manufacturers offer our systems as standard equipment or factory options Lincoln builds precision metal compo nents state of the art electronic con trols and the industry s top performing pump systems Our quality systems in the United States and Germany are ISO 9001 registered With five technical support centers on three continents and a network of systems houses and distributors suppor ted by regional sales and service offi
9. Sheetmetal 10461 14 NPT male x NPT female reducing bushing eT Nesmtha Bulkhead Adapters Modeino sye 1 s coc Job Na SASS NuR 13154 1 4 PTF 75 12 7 mm 4 28 Jc 4 8 mm 23 64 9 1mm 14054 Ye PTF v 12 7 mm 14 16 4 mm asap siy i 727127 mm 70148 mm LA No 91093 Nut 74 NPT 74 hex i t B NPSM P Thd Steel gt lt D Bulkhead Sheetmetal No 51055 SKF 29 LINCOLN Quicklub Lubrication Systems LINCOLN Fittings Adapters and Accessories aes Metric Adapters Model No Description 20042 M6X1 male x NPSF female straight 20043 M6X1 male x NPSF female 90 244201 74 BSPT male x NPT female thread 304 19166 1 M6X1 male x Ya 28 SAE female 304 19165 1 M8X1 male x 1 4 28 SAE female 304 19164 1 M10X1 male x 1 4 28 SAE female 241650 74 BSPT male x NPT female thread stainless steel 273482 M8X1 male x NPT female straight 277307 M8X1 female x M8X1 25 male 90 Contact Lincoln for a complete metric Quicklub catalog C Hex Zerk Lock Grease Fitting Adapter PA Connects any 75 NPTF male tube adapter directly to a standard grease fitting Aluminum carbon steel construction fluorocarbon elastomer seal B Dimensions L Model No Thread A B C Hex in mm in mm in mm I 270784 7a NPSL Female 625 15 9 500 12 7 500 12 7 Note Zerk Lock with a straight female thread is designed to accept a tube c
10. ves 6Ak401708 P2054YIB01KBACHAT01 UD Sv Amer on Yes No UL in the description refers to UL approved CSA certified pumps Pumps with A SV come complete with the 4 NPT adapter and pressure relief valve 241 229 350 395 250 SKF 11 ae Quicklub Lubrication Systems LINCOLN Identification Code Pump Models 203 Examples of Codes P203 2 X N 1 K6 24 1A 1 10 Note P203 4 X N BO 1 KR 24 2A 6 15 M13 Any pumps combination other than the above standard P203 2 X N 2 K5 12 1A 1 10 H pumps can be composed and ordered in accordance P203 8 X N BO 1 K6 24 1A 5 14 V13 with the valid model identification code P203 4 Y L BO 1 K7 24 1A 1 10 V20 Basic pump model for grease or oil with 1 3 outlets g P 203 2 X L 1 K6 24 1A 7 16 V10 Reservoir Design 2 2 transparent plastic reservoir 4 4 transparent plastic reservoir 8 8 transparent plastic reservoir 15 15 I transparent plastic reservoir X reservoir for grease Y reservoir for oil N standard design L low level control without designation standard reservoir 2 BO filling from top FL flat type reservoir for 2l no low level Pumping Element 1 3 number of elements Piston Type Piston Diameter selection see page 20 K5 5mm K6 6 mm K7 7 mm KR adjustable 7 mm B7 7 mm outlet same as K5 S7 7 mm food industry Operating Voltage 12 VDC or 24 VDC DC moto
11. without designation without p c b M08 M23 with microprocessor control 3 different model in accordance to the jumper position No designation pump without control p c b The Figures are in conjunction with those of the Type of connection determining the connector you could use For hazardous material transport 8 C7 for supply of chisel paste low level for oil the connection for low level is not taken into consideration Special order Quicklub pumps require a delivery time of six to eight weeks LINCOLN 12 aKF Quicklub Lubrication Systems LINCOLN aa Electric Grease Pumps 233 Series 233 Pumps with Data Logger QuickData The 233 centralized lubrication pump is a powerful and robust compact multi line pump that can drive up to three elements and is used in progressive Quicklub or Modular Lube automated lubrication systems The 233 is ideal for mobile applications rental machines and construction machines Versatile compact and economical this pump is enhanced with low level control printed circuit board MDF01 with attached data logger module and a keypad with display QuickData Displays Current status and operating data Malfunctions of the lubrication system with the time of occurrence Remedying of the malfunction with date time and duration of malfunction Low level signal of reservoir and regular refilling Modifications in the pause time programming Number of automatically and manuall
12. 0 35 in E Model Specifications i m mN ja Model No Valve Type Valve Mount 0 cia K y W P301 31411154 SSVE 24 DC 30 10m Note All models include low level LINCOLN e 18 aKF Quicklub Lubrication Systems LINCOLN Electric Oil Pumps QLS 311 Series laa QLS 311 Unitincludes pump control monitor and metering valve and is ready to go out of the box Pump includes built in controller with LED display and keypad for easy programming system cycle monitoring a built in low level control and remote monitoring capability Unit offers the advantages of automated lubrication including reduced downtime and improved safety to machinery large and small Operating Voltage 12 and 24 VDC 120 and 230 VAC 50 60 Hz Operating Current 12 VDC 2 0A 24 VDC 1 0A 120 VAC 1 0 A 230 VAC 0 5A Operating Temperature 10 to 158 F 25 to 70 C Number of Outlets 6 8 12 or 18 Reservoir Capacity 61 in 1 0L Protection NEMA 4 Lubrication Cycle Time AC 20 min to 60 hours DC 4 min to 60 hours m 230 mm 9 05 in d t ja mm 7 24 in Number of Cycles For VDC 1 to 5 cycles ho SF 61 For VAC SSV6 SSV8 1 to 3 cycles For SSV12 SSV18 1 cycle Su g Timer Memory Indefinite 85 32 E pa Max Operating Pressure 1160 psig 80 bar SES g si Output per Outlet amp Cycle approx 0 012 in approx 0 2 cm Lubricant oil with at least 40cSt Weight
13. 25 PIPE FITTINGS Reducing Bushings Nipples Couplings Reducing Couplings Street Ells Tees Crosses Adapter Unions Elbows Pipe Fitting Adapters Supply Line Swivels Feed Line Swivels Anchor and Junction Blocks LINCOLN D occ Quicklub Lubrication Systems LINCOLN Fittings Adapters and Accessories ES r Divider Valve Mounting Accessories C C 4 nylon locknut for valve mounting Grade 8 7a valve mounting bolt y Standard Compression Fittings for Steel mE or Nylon Tubing w Model No i 241290 Ja tube x NPT male straight fitting 241293 Ja tube x 78 NPT male 90 fitting Divider Valve Outlet Adapters for 1 4 O D Steel or 4 n Nylon Tubing Compression Style With Check Valve Ferrule 7 Ca i Divider Valve Outlet Adapters for O D Steel m or Nylon Tubing Compression Style Without Check Valve Compression nut stainless steel Ferrule Divider Valve Outlet Adapters for 2 I D Hose E E Description L JS Ferrule Valve outlet adapter with check NPT female Valve outlet adapter without check 7s NPT female For SSVM Valves Compression Fitting ome PG Feed ee Ine guinea Mees Material connection 13112 419 22990 1 Adapter 419 226152 a 519 30583 1 Check valve body NOTE Quicklub adapters without check valves are for use in oil systems with open tube minimal backpressure Quicklub adapters with check valves are for use i
14. 12 5 Ibs 5 7 kg H Model Specifications Note All models come with a low level indicator e 215 mm 8 46 in SKF 19 pus Quicklub Lubrication Systems Electric Grease Oil Pumps QLS 301 311 Series up the external controller Operating Voltage Operating Current Operating Temperature Number of Outlets Reservoir Capacity Protection Minimum Pause Time Maximum Operating Time Timer Memory Output per Outlet amp Cycle Lubricant Weight 270 mmy 10 62 in Bottom Mount 146 mm 5 74 in Shaam L7 0 35 in 215 mm 8 46 in 20 Maximum Operating Pressure Model Specifications Prairie sse ga avc o rarer ssvz Back awc o Grease os0407054 seve Bottom wovac o LINCOLN EIE QLS 301 311 for Remote Control The QLS 301 311 for Remote Control allows customers to be in control of the lubrication process The 24 VDC models monitor system cycling with a proximity Switch An external timer or PLC controls the interval between lube cycles The 120 VAC models have no cycle monitoring and are on off controlled by the user s external timer or PLC The minimum pause time requirements should be followed when setting 24 VDC 120 VAC 50 60 Hz 24 VDC 1 0A 120 VAC 1 0A 10 to 158 F 25 to 70 C 6 8 12 or 18 61 in 1 0L NEMA 4 4 min DC models 20 min AC models 25 min DC models 15 min AC models Indef
15. 158 F 25 C to 70 C 4000 psi 250 psi 276 bar 17 bar Note Do not use pump without pressure relief valve Protected from water sprayed in all directions Model Specifications Control Settings Reservoir Capacity Interval Interval Model No Description Between Between f Liters Lbs Lube Lube k Cycle Min Cycle Hrs E mU e 7 BET eee eue Pzssusockezenmeisunesv neo aeo 116 soso e pee vo oeza rzesxcweneznersuseesv voc acm 1 15 soso e pee vo CO TA ao 118 sora om o COURT voc areo 116 sorso e pe 16 secar P207XLPOIKEAC3A6151105 _ wovac aeo 118 sorso vo These 644 pumps do not come with the pressure relief valve It must be ordered separately and is recommended The 4 NPT adapter 304 19614 1 is also not included and must be ordered separately if required None of the above pumps come with the proximity switch This must be ordered separately SKF 9 LINCOLN Quicklub Lubrication Systems LINCOLN Electric Grease Pumps 203 Series Electric Grease Pump with RemoteLinc Technology Easily interfaces with OEM and aftermarket telematics systems Allows users to Remotely monitor and detect low lubricant levels and system faults Reduce cost by receiving immediate real time alerts when lubricant is low or the system is in fault Electrical Requirements 12 VDC 3 5 amps 24 VDC 2 amps Input 94 265
16. 649 20636 1 ve Note You must use outlets 1 amp 2 for each of the above reference models to allow the system to operate properly Metering Adjustment Screws Output Model Number Output Model Number cu in cc Sold as Each Bag of 12 cu in cc Sold as Each Bag of 12 0049 0 08 303 16118 1 549 34254 1 037 0 6 303 16123 1 549 34254 6 0085 0 14 303 16119 1 549 34254 2 049 0 8 303 16124 1 549 34254 7 Yes No Yes 10 12 14 16 18 20 2 018 0 3 303 16121 1 549 34254 4 085 1 4 303 16126 1 549 34254 9 012 0 2 303 16120 1 549 34254 3 061 1 0 303 16125 1 549 34254 8 024 0 4 303 16122 1 549 34254 5 110 1 8 303 16127 1 549 34255 1 LINCOLN 6 SKF Quicklub Lubrication Systems LINCOLN aaa Divider Valves SSV D Metering Device with Outlets 1 amp 2 Together For added installation flexibility outlets 1 and 2 can be singled together In this configuration outlets 1 and 2 are internally connected thus doubling the output through one output port See the chart below for models and outlet configurations Specifications Construction Max Operating Output Outlet Pair Stroke Lubricant Lubricant Operating Temperate Material Pressure cu in cc Inlet Outlet P 9 p Carbon Steel 5076 psig 350 bar Min 0049 08 Max 110 1 8 Ja NPTF F M10x1 13 F to 158 F 25 C to 70 C 649 29543 1 NPT SSVD 12 11 V1 A Note A plug must be installed in outlets 1 or 2 but not both
17. 8 or SSV 12 and 18 without control p c b 0 External SSV 12 SSV 182 00 2 1 SSV 6 BACK eroaan epit sek unes eu oR sguardi natos ence Sek drap tend essi n 3 SOV 8 DOOM oe peer SENI MEC HE ev etki Wandin 4 SSV 12 paman DRI GAGA Au aA pes BANDA ca Y VAYA QU prar Aa d ees es 6 SON Ga nA eSI TERME EI D Gu ate eee EE 9 Note For external divider block application only use the specific divider blocks SSV KNQLS SSV Divider Block Position External divider block 0000 cee ene 0 Back vertical order a naa cece eee caue e ad eee es ey e a e d dora 1 Bottom horizontal order II 2 3 Note Do not use QLS 401 with SSV block in bottom mounting position for mobile applications Do not install the pump in areas exposed to shock Operating Voltage 12 VDO iid ou Seb abe bad sid qo d D dedu dd idea due dd Suppe 2 24 NDC ze hind euge RR RR ERR NE RB RE REG quaerat e uh 4 120 VAC with control p c b only B 6 230 VAC with control p c b only I 8 Note Standard 12 and 24 VDC pump models for mobile applications can be supplied with 10 meter 30 electrical cable Note Standard 120 and 230 VAC pump models for industry are supplied without electrical cable Reservoir 1 liter reservoir without low level control llle 0 1 liter reservoir with low level control 0 0 0 0 cece ee ee eee 1 2 liter reservoir without low level control 0 0
18. Bulb voc 237133813 Replacement Bulb awc 256105004 Replacementlens Green 236142619 Repaemenien Relo Pressure Relief Valves Model No Pressure Relief Setting Supply Line Connection 270864 4000 psi 270 bar 1 8 NPT female 624 28894 1 5076 psi 350 bar 6 mm Compression Nut 624 28895 1 5076 psi 350 bar 8 mm Compression Nut 624 28931 1 5076 psi 350 bar 6 mm Quicklinc 304 19614 1 Adapter 6 mm Stem x 1 8 NPT female 6 mm x NPT supply line adapter Model 304 19614 1 can be used to convert supply line connection to NPT for these models Return to tank Note Model 226 14105 5 psi relief adapter is required for 4 8 and 15 liter pump models Proximity Switches Electric grease pumps with Feedback Monitoring require purchase of one of the following proximity switches Model No Description Hse wis Corresponding Pump Connection 519 34339 3 Bayonet 3 m 9 8 cable length 4 bayonet quarter turn 519 34339 4 Bayonet 7 m 23 0 cable length 4 bayonet quarter turn 519 34271 7 AMP 3 m 9 8 cable length 4 AMP existing field models 519 34271 8 AMP 7 m 23 0 cable length 4 AMP existing field models SKF 23 LINCOLN Quicklub Lubrication Systems LINCOLN Pump Accessories SSeS Pump Elements Piston Max Operating Connection 600 26875 2 5 mm 5K 122 in min 2 cm3 min 171 in min 2 8 cm min 600 29304 1 Bever
19. a 2 2 liter reservoir with low level control 0 0 0 0 ee ees 3 Number of Possible Connections 1A connection left side square type supply voltage 0 2A 2 connections square type 0 eect eee 1 connection left side supply voltage 0 c eee eee eee 1 1 connection right side low level control or fault indication 1A 1 connection quarter turn bayonet type supply voltage low level control or fault indication DC models only 2 Type of Plug Connector Square type acc to DIN 43650 type of construction A 1 industrial application Quarter turn bayonet type plug DIN 72585 1 4 pole mobile application DC models only 0000 cece eee 5 Electrical Connectors With socket without cable 0 0 rn 1 With socket with cable 10 mM 0 0 0 0 RR 5 With socket with cable 10 m DC models only cece eee eee 7 Control p c b p c b without time control DC models 0000 c eee ee 0 p c b S4 Normally closed or normally open contact programmable monitored to 5 cycles DC models 00 0 cece eese 1 cycle with SSV 12 SSV 18 AC models 1 to 3 cycles with SSV 6 SSV 8 AC models aaa 4 SKF 17 ae Quicklub Lubrication Systems Electric Grease Pumps QLS 301 Series LINCOLN eee LINCOLN jo QLS 301 pump horizontally
20. filler pump 4 and 8 liter and 2 liter flat type 246322 Remote push button manual lube upgrade kit for pumps with square DIN connectors field replacement only 256276 Remote push button manual lube kit for pumps with bayonet round connectors Model No Description er 6 wire cord 273921 Universal quickfill adapter for 2 4 and 8 liter pumps 638 37549 1 538 36763 5 Fill adapter for 4 and 8 liter pumps 7 538 36763 4 90 fill adapter for 4 and 8 liter pumps G 538 36763 1 Fill adapter for 2 liter pumps 241052 7 5 Amp fuse C 241053 Standard fuse holder Ka 276409 Heavy duty fuse holder 273921 664 34195 9 45 5 wire power cord round bayonet LINCOLN 24 SKF Quicklub Lubrication Systems Installation Components LINCOLN a Lubricant flows through supply lines between the pump and divider valves then through feed lines between the divider valves and the bearing Tubing and or pipe sizes are determined after considering both the length of the line and the specific lubricant intended for use in the system Your Lincoln representative can assist you in the proper selection of supply and feed line material to optimize your application Listed below is a simplified outline of the installation components offered For a complete listing of products please refer to the pages in this catalog entitled Fittings Adapters and Accessories Additional installation componentry can be found in the Installation Componen
21. for the above referenced models to allow the system to operate properly One metering screw needed per outlet pair for SSV D metering device SKF 7 LINCOLN Quicklub Lubrication Systems LINCOLN Electric Grease Pumps 203 Series P203 Series Pump These pumps are electrically operated and are used in progressive type automated lubrication systems The proven and reliable P203 pump has been designed to develop high operating pressures allowing it to supply NLGI 2 grease in most ambient temperatures Versatile compact and ecomomical this pump can be enhanced with several options including an integrated controller low level monitoring and system monitoring Special configurations are available upon request Note Customer must furnish a 12 or 24 volt D C power source Electric Grease Pumps with Integrated On Off Controller Output Min Per Element 171 cu in 2 8 cc Lubricant Outlet 7s NPT F Max System Operating Pressure 5000 psig 350 bar Enclosure Rating IP6K9K Operating Temperature Range Min 13 F 25 C Max 158 F 70 C Reservoir Capacity 2 4 8 or 15 liter Reservoir Fill Method By grease fitting Pressure Relief Valve 4000 psi 250 psi 276 bar 17 bar Protected from water sprayed in all directions Single 6mm element standard to increase pump output add one or two additional element s 600 26876 2 and relief valve 270864 Pressure relief valve
22. information contained herein December 2014 FORM 442833 LINCOLN OEIL LOOoONll skf com
23. system that delivers precise amounts of lubricant fully monitored with the divider valve s indicator pin Kits include 100 14 nylon tubing 12 straight Quicklinc tube fittings 12 Zerk Lock adapters mounting clips and hardware Quicklub Centralized Lubrication Kits Single point kits contain all items required to install a system on your machinery including a complete installation service manual The selection chart describes the models available to meet your specific needs Tm Da F Non filled Kit with single fitting for use with portable grease gun Pre filled 87412 Complete kit with grease gun for permanent mounting Pre filled LINCOLN 32 SKF Quicklub Lubrication Systems LINCOLN Kits KA Trailer Kits Unassembled Trailer Kits Preassembled Model Ri 244512 12 point manual QL kit tandem axle Note Above referenced kits require purchase of electric grease pump see Pump section of this catalog when fully automated system is desired SKF 33 Quicklub Lubrication Systems LINCOLN Kits Tractor Truck Kits Unassembled Kits Description Manual Kits Automated Kits 24 point QL kit 241324 241124 includes 241324 and 94012 28 point QL kit 241328 241128 includes 241328 and 94012 32 point QL kit 241332 241132 includes 241332 and 94012 33 point QL kit 241333 241133 includes 241333 and 94012 ere 9299999999 000000000 POS B90969 64 VPE zz PEEP PY 494949 PA
24. the hammer and your operator with the push of a pedal automatically sends a single shot of hydraulic fluid to the pump Then the pump gives one shot of grease to lubricate the bearing points When the operator s foot comes off the pedal pressure releases the spring in the pump so it s ready to lubricate again Applications construction OEMs hydraulic hammer retrofits demolition attachments and medium to larger breakers hammers Withstands vibrations of an operating hammer Travels with hammer perfect for rental equipment or hammers used on various machines Hydraulic power supply Pedal actuated Attached grease fitting allows for manual filling and fast priming of pump Uses standard 14 5 ounce grease cartridges and handles chisel paste To adjust output metering plugs are available 0 006 in 0 1cm to 0 031 in O 5cm Convenient visual low level indicator Operating Temperature 10 F to 180 F 23 C to 80 C Hydraulic Port SAE 4 746 20 UNF O ring Pump Outlet SAE 4 4s 20 UNF O ring Weight Empty 16 3 Ibs 7 4 kg Weight Full 17 3 Ibs 7 8 kg Specifications Model No 85429 85425 85424 85414 Hydraulic Ratio at Max Output and Pressure Max Hydraulic 2600 psig 5000 345 b Operating Pressure 112 bar psig ar Max Recharge or Vent 400 psig 1100 psig 600 psig 1100 psig Pressure 28 bar 75 bar 41 bar 75 bar Max Lube Outlet 6500 psig 450 bar Pressure Output pe
25. 2811114 19 619 27476 1 4 649 295421 91048 i 30 P311 91211154 19 619 27478 1 4 649 29543 1 T 91308 s 30 P311 91411154 19 619 28899 1 4 649 295441 7 4 94012 PDEA bees 8 P311 92611114 19 619 28900 1 4 649 295451 6 94024 coss 8 P311 92811114 19 619 28901 1 4 649 295461 6 19421212 one Ampang 8 P401 31202574 15 619 28902 1 4 649 295471 6 94222 aa pamana eens s 9 P401 31401110 16 619 29067 1 4 649 295481 6 94223 12 02 22 2008 56 10 P401 31402574 15 619 29400 1 4 649 295491 6 94223 AC 10 P40142601114 15 619 29401 1 4 649 295501 T 94223 aaa 10 P40142801114 15 619 36732 1 5 649 29551 1 PN 94224 aa na wae AG 8 P401 61202574 15 619 36732 2 5 649 295521 T944 2 aan Be aed NGA 8 P401 61401110 16 619 77254 1 4 649 295531 7 94412LDL 8 P401 61402574 15 6217 5 e bene Kk iea 29 649 295541 TIN 94422 kno 9 P401 62601114 15 622502 8 EE 29 649 29627 1 6 94423 12 iLuuee 10 P401 62801114 1
26. 5 062218 es ee issus 29 649 29628 1 6 94423 AC 10 P401 91202574 15 02357 vices SERRE E 28 649 296291 6 94423 lala 10 P401 91401110 16 624 28894 1 23 649 29630 1 6 94423LDL 10 P401 91402574 15 624 28895 1 23 649 296311 7 94424 la 8 P401 92601114 15 624 28931 1 23 649 296321 7 94434LDL 13 P401 92801114 15 62950 ope DER ee 29 649 29633 1 7 94812 Lss 8 P42161202531 21 638 37549 1 24 649 296341 7 94812LDL 8 P421 61222531 21 638 37549 2 24 649 296351 6 94822 aaa 9 P421 91202531 21 644 40821 6 9 649 29636 1 6 94822LDL 9 P421 91402531 21 644 40822 8 9 649 29637 1 6 94823 10 V325120000 24 644 40824 1 13 649 29638 1 6 94823 12 10 644 40824 2 13 649 29639 1 7 94823 AC 10 644 40826 1 13 649 29640 1 7 94823LDL 10 644 40827 1 13 649 29641 1 7 94824 0 la 8 644 40843 8 9 649 29642 1 7 94824LDL
27. 7 LINCOLN Quicklub Lubrication Systems LINCOLN Fittings Adapters and Accessories esas Divider Valve Outlet Closure Plug Description Valve outlet closure plug gasket not required 303 19346 2 Stainless steel outlet closure plug gasket not required Ye Supply and Feed Line Hose Lube Working Minimum i Nylon Tube 4000 psig Dacron Braid 276 bar Polyurethane Cover Model No Description ID hose 26 ft 7 92 m coil grease filled 35 ft 10 66 m coil grease filled AO ft 12 19 m coil grease filled 200 ft 60 96 m coil non grease filled 2250 ft 685 8 m spool non grease filled 276395 40 ft 12 19 m grease filled with quick wrap protection installed on hose Description Hose stud 90 to be used with 272427 Description Ys NPT swedge on hose stud Requires swedging tool 7a NPT field installable hose coupling swedging tool not required 7a NPT swedge on hose fitting with swivel requires swedging tool Hose End Connecting Tools Model No Description 241238 Hose Swedging Tool Hand vise for quick connect and reusable hose ends Feed Line Nylon Tubing Working ini Wall Minimum Model Description Thickness Bending in mm psig bar Radius 242025 25 ft 7 6 m coil grease filled 242050 50 ft 15 2 m coil grease filled o EI pex 050 127 625 425 8751222 SE to 62357 100 ft 30 5 m coil non grease filled 247022 500 ft 152 40 m coil non grease filled
28. 7474 1 Y N N 619 29067 1 N Y 20 NNNM z w o es o es es o es o Yes o es es Yes es Y SSV Divider Valve Accessories 249010 Cycle switch for providing feedback monitoring for SSV systems 11 cable 26 gauge wire Note Cycle switch can only be used with SSV Series Quicklub valves that have indicator pins Remove slotted plug from indicator assembly on valve prior to installing switch LINCOLN 4 SKF Quicklub Lubrication Systems LINCOLN aa Divider Valves SSVM Divider Valves P tuae j 50 mm Pea The SSVM Divider Valve is smaller in overall size than the SSV series and provides smaller volume output per outlet Available with six to 12 outlets the SSVM series valve is used primarily in oil system applications Specifications Construction Maximum Output Cycle per Outlet Lubricant Lubricant Operating Temperatur Material Operating Pressure cu in cc Inlet Outlet Min Max Carbon Steel 2900 psig 200 bar 0037 07 78 NPTF F M amp t1 22F 25c 212 F 70 Model No F Maximum Number of Outlets Cycle Indicator Pin Dimension A Carbon Steel in mm 1 91 48 5 619 26765 3 Yes 2 36 60 619 26651 3 Yes 10 2 81 71 5 12 3 26 83 Note You must use outlets 1 and 2 for each of the above referenced models to allow the system to operate properly Divider Valve Accessories 619 36732 1 Demonstration Valve see through block 619 36732 2 Cut awa
29. RES PEPE CPP PH PP PP EE Preassembled Manual Kits Model No Description 247232 32 point manual preassembled kit Note Above referenced kits require purchase of electric grease pump see Pump section of this catalog when fully automated system is desired LINCOLN 34 SKF Quicklub Lubrication Systems LINCOLN E Numerical Index Model No Page No Model No Page No Model No Page No Model No Page No 674 etu Soo ape aa 24 241324 34 272633 23 304 196141 9 23 10190 AA 29 241328 34 272634 23 404 20236 4 26 10181 or ERR 29 241332 34 272643 23 404 22581 2 26 10182 hahha 29 24133BP3 34 272658 27 404 22602 1 26 N0461 aaa anes wan 29 241650 4 30 272659 27 404 23668 1 26 13112 ee Eee 26 242025 28 273422 iocos 23 4192261822 26 19129 i xe etm eee ia 29 242050 28 273425 23 419 22990 1 26 19154 EpL ERR REPE 29 242125 29 273426 23 432 243131 27 191559 s es enu E pom ous 29 243699 27 273482 30 444 70490 1 14 14054 ori ele 29 24404T7 20 273921 eios 24 444 704911
30. VAC 50 to 60 Hz Enclosure Rating IP6K9K Interval Between Lube Cycles Min 4 minutes Max 15 hours Pump Output 0 171 cu in min 2 8 cc min Outlet Connection 1 8 NPT F Reservoir Capacity 2 4 8 or 15 liter Maximum Recommended o Operating Pressure 9900 a ca Greases NLGI grade 2 depending on operating Lubricant temperature and type of lubricant Temperature Range 13 F to 158 F 25 C to 70 C Pressure Relief Valve 4000 psi 250 psi 276 bar 17 bar Model Specifications None of the above pumps come with a proximity switch This must be ordered separately LINCOLN 10 aKF Quicklub Lubrication Systems LINCOLN Electric Grease Pumps 203 Series 203 AC Models This VAC pump automatically adjusts to handle a variety of electrical supply voltages between 94 and 265 volt 50 to 60 Hz EL Input Voltage 94 265 VAC 3 Amps L INCOLN Operating Temperature 13 to 158 F 25 to 70 C Number and Element Size 1 6mm Reservoir Capacity 2 4 8 or 15 liter Output per Minute Approx 2 8 cc 0 171 cu in per min Lubricant Greases up to NGLI 2 Oil with at least 40 cSt Max Operating Pressure 5076 psi 350 bar Contact Lincoln for 15 liter reservoir models saso Model Specifications T i i Bes Grease Low Printed Model No Description p circuit Cap or Oil board 044 461735 P209 4VLBOAIKG ACAAT ONVIOUL ArSV Amer on Yes
31. age eed Grease G 1 4 600 28750 1 7 mm 7C Hammer Chisel Paste 350 bar 244 in min 4 cm min 600 29110 1 7 mm S7 Silicon Based Grease 600 29185 1 7 mm B7 Silicon Based Grease senes omen PAO Grease and chisel paste compatibility should be confirmed with Lincoln Technical Galvanized pump elements to withstand corrosion Special element designed to be used for applications on hydraulic hammers With bypass check valve Adjustable lubricant output pump element Model 85830 ALS Fill Pump Air operated grease pump designed to fill pump reservoirs from drums Includes pump drum cover high pressure hose outlet swivel control valve and universal swivel whip hose coupler and universal follower For use with 120 Ib drums not included Fill nipple is not included and must be ordered separately Model Bare Pump Max Working Max Air Lube No Pump Ratio Pressure Pressure Outlet 3 8 ID x 10 SAE 100R2 high 3750 psi 150 psi 3 8 NPT 1 4 NPT 85830 V325120000 258 bar 10 3 bar female female peso SESS bar ALS Fill Pump Accessories Model No Description 277059 Fill nipple long for 203 pump 277057 Grease coupler 3 8 NPTF female inlet 85830 674 Two wheel hand cart to make package portable pede 80895 Caster base to make package portable Quicklub Pump Accessories y _ 638 37549 1 Manual grease filler pump 2 liter 638 37549 2 Manual grease
32. ces our customers can always draw on our worldwide resources To make sure your investment results in significant savings Lincoln developed a unique program called BearingSaver You not only get a complete audit of your facility you also receive an analysis of your return on investment LINCOLN zzz aKF Quicklub Lubrication Systems LINCOLN Table of Contents a ener Introduction to Quicklub 2 SSV Divider Valves leer 4 SSVM Divider Valves leeren 5 SSV D Divider Valves leere 6 with Outlets 1 and 2 Together 7 Electric Grease Pumps leen 8 203 SBIIBS i505 uoUySERRRRRAREERERRX PPRSISRa 8 233 SerieS 2 unsa kawa rape Rar eee ET KA GALA 13 Reservoir Field Upgrades 14 QLS 401 Series lll 15 QLS 301 Seres oossoasoowhkwo 34 ER nra 18 QLS 311 SONGS LorcsRh4re3 Rr EEG eai 19 QLS 421 Series lll l 21 HAWG 22 0 BALA BK KE LENG MAGAT Ri Ea ed 22 Pump Accessories rers 24 Installation Components 25 Fittings Adapters and Accessories 26 Single Point Lubrication Kits 32 Numerical Index lerrllre 35 SKF 1 ae Quicklub Lubrication Systems LINCOLN Introduction to Quicklub CENA The Lincoln Quicklub system is designed to provide a relatively simple and inexpen
33. eal and tighten 4 Then thread a 5 And plug the tube into the divider onto the fitting Zerk Lock using Quicklinc into the Quicklinc valve and insert a hammer and completely into adapter the line staking tool the Zerk Lock Quicklinc Push In Style Fittings for Nylon Tubing Model No Description 244047 Ja tube x NPT male straight fitting 244048 Ya tube x NPT male 90 fitting 243699 Ya tube x NPT male 90 swivel fitting 244053 Ya tube x Ya 28 male 90 swivel fitting 244054 Ja tube x Ya 28 male 90 fitting 244055 Ja tube x Ya 28 male straight fitting 244056 Ja tube x 6x1 mm male 90 fitting 74 tube x 6x1 mm straight fitting Ya tube x 74 tube splicer union Divider Valve Outlet Adapters for O D Nylon Tubing Quicklinc Push In Style Model No 244883 Valve outlet fitting with check M10x1 thread Valve outlet fitting without check M10x1 thread Divider Valve Outlet amp Inlet Adapters for 1 I D Mans Hose Quicklinc Push In Style with Check y i 272658 Valve outlet fitting with check Use with 272401 and 272394 hose stud M10x1 thread 3 272659 7a NPT male straight fitting Use with 272401 and 272394 hose stud i IMPORTANT Use the valve adapters for connecting the high pressure hose incl hose stud with groove to the main divider valve The collet of the adapter is not knurled and has a wide collar T Model No Description 432 24313 1 Protective Quicklinc rubber boot SKF 2
34. h outlets SKF 3 pus Quicklub Lubrication Systems LINCOLN Divider Valves SSV Divider Valves 30 mm L sx en The SSV Divider Valve is the heart of a manual or automated Quicklub system Featuring from six to 22 outlets the SSV valve is available in carbon steel and 303 stainless steel for corrosive environments Valves are available with cycle indicator pins to provide visual indication of system operation Specifications Construction Max Operating Pressure Output Cycle per Outlet Lubricant Lubricant Operating Temperature Material Min Operating Pressure cu in cc Inlet Outlet Carbon Steel 5076 psig 350 bar 012 2 Ys NPTF F M1Ox1 22 F 212 F Stainless Steel 290 psig 20 bar i 1 4 BSPP F 30 C 100 C Note Lubricant outlet must use Lincoln Quicklub fittings See Divider Valve Accessories section 241650 stainless steel adapter available to convert inlet to 78 NPTF F F Model No Maximum Number Dimension A Cycle Indicator Pin G Carbon Steel 303 Stainless Steel of Outlets in mm 619 27121 1 619 27122 1 619 26396 2 619 26646 2 619 26844 1 619 26845 2 619 26398 2 619 26648 2 619 29400 1 619 28899 1 619 29401 1 619 28900 1 619 28901 1 619 28902 1 619 77254 1 2 36 60 2 95 75 5 9 150 6 5 165 7 1 180 Note You must use outlets 1 and 2 for each of the above referenced models to allow the system to operate properly N N 619 2
35. included with these models Model Specifications Interval Timer Setting Reservoir Reservoir Capacity Model Electrical On Time Off Time No Requirements 2 minute increments 1 hour increment 94012 a la 12 VDC 3 5 E 7 2 2 minutes 30 minutes 1 hour 15 hours ee 94024 94424 j ee 24 VDC 2 Amp eS E 46278 644 46278 1 j Can be set for either minutes or seconds Electric Grease Pumps Without Integrated Controller Model Specifications Model N EikikedEaad A Reservoir Capacity odel No ectrical Requirements j E e Le 94224 24 VDC 2 Amps is o 94212 12 VDC 3 5 Amps i LINCOLN 8 SKF Quicklub Lubrication Systems Electric Grease Pumps 203 Series LINCOLN aaa LINCOLN SiS Electric Grease Pumps with Low Level Sensor Electrical Requirements Input Enclosure Rating Interval Between Lube Cycles Pump Output Outlet Connection Reservoir Capacity Maximum Recommended Operating Pressure Lubricant Temperature Range Pressure Relief Valve and Integrated Controller for Feedback Monitoring Supplies NLGI 2 grease depending on temperature to divider valves 12 VDC 3 5 amps 24 VDC 2 amps 94 265 VAC 50 to 60 Hz IP6K9K Min 4 minutes Max 15 hours 0 171 cu in min 2 8 cc min Ye NPT F 2 4 8 or 15 liter 5000 psi 350 bar Greases NLGI grade 2 depending on operating temperature and type of lubricant 13 F to
36. industries and applications eliminating costly manual point by point lubrication Examples include Mobile Equipment Industrial Equipment Over the road tractors Wheel loaders e Packaging Bakery Single axle trailers e Hydraulic excavators Lathes Printing Tandem axle trailers Motor graders Beverage industry e Punch presses Tri axle trailers e Backhoe loaders Textile e Paper converting Yard tractors Hydraulic hammers e Metal working e Milling Trucks of all types Street sweepers Wood processing Plastic processing e Refuse haulers Road amp highway e Material handling Wind energy paving equipment equipment LINCOLN 2 SKF Quicklub Lubrication Systems LINCOLN Introduction to Quicklub The heart of the Quicklub system More than a drilled manifold block the valve incorporates a series of metering pistons which accurately dispense lubricant from each outlet overcoming back pressure of up to 1 000 psi Visual monitoring is provided with an indicator pin which confirms a valve has completed a full cycle Quicklub divider valves are available for grease or oil applications and in carbon steel and 303 stainless steel for corrosive environments Figure 1 Figure 2 The inlet passageway is connected to all piston chambers at all times with only one piston free to move at any time With all pistons at the far right lubricant from the inlet flows against the right end of
37. inite Grease 3000 psig 205 bar Oil 1160 psi 80 bar approx 0 012 in approx 0 2 cm up to NLGI 2 grease or oil with at least 40cSt 12 5 Ibs 5 7 kg Grease aKF Quicklub Lubrication Systems LINCOLN Electric Grease Pumps QLS 421 Series aa QLS 421 Accurate lubrication without the need for continuous power that s what over theroad trailers need That s exactly what Lincoln s QLS 421 supplies With a unique controller card that keeps track of the time a trailer is in use by monitoring its vibration the QLS 421 delivers the precise lubrication an OTR trailer requires exactly when it s needed by using the power of the trailer s brake lights Because it doesn t need power to monitor the time between lubrication events the QLS 421 is ready when its controller card says go And the QLS 421 keeps lubricating each time the trailer s brakes are applied until its controller card adds up the on times and determines that the pre set time for a complete lubrication cycle has been reached The QLS 421 features an enhanced stirring paddle to help prevent grease separation in applications with long refill intervals Operating Voltage 12 and 24 VDC Operating Current 12 VDC 2 0A 24VDC 1 0A Operating Temperature 10 to 158 F 25 to 70 C p 280 mm 9 05 in E Number of Outlets 6 12 or 18 SS I INR Reservoir Capacity 61 in 1 0L Protection NEMA 4 t S Time Between Cyc
38. les 1 hour to 16 hours B EE On Time Range 1 to 32 min g 8 Timer Memory Indefinite Maximum Operating Pressure 3000 psig 205 bar m Output per Outlet per Valve Cycle approx 0 012 in approx 0 2 cm Lubricant up to NLGI 2 grease i Weight 12 5 Ibs 5 7 kg agencies Model Specifications Reservoir Valve siaa Vave Hee Size D i i 215 mm 8 46 in P421 91402531 24 VDC SSV18 HO P421 61202531 SSV12 1 liter pack 19 feet E i ac P421 91202531 12 VDC SSVi8 6 meters EET 61222531 Le SKF 21 ae Quicklub Lubrication Systems LINCOLN BEENDEN Hammer Pumps HTL Hydraulic Lubricator Pump for Hammers Delivers precise lubrication every time the hammer cycles Increase productivity no work interruption Reduces machine repairs and replacement costs Arms and breakers move constantly and exert enough force to demolish a building or repair roads in a tough environment filled with grit and debris OEMs recommend bearing lubrication of that hammer every two hours to achieve optimal performance and to hold down maintenance and repair costs However deadline driven operators rarely halt work to grease the hammer which can lead to breakdowns that grind down productivity and inflate repair expenses Lincoln s HTL Pumps make precise consistent lubrication a reality Now your operator can lubricate the hammer without leaving the cab The pumps attach directly to
39. lows customers to be in control of the lubrication process The 24 VDC models monitor system cycling with a proximity switch An external timer or PLC controls the interval between lube cycles The 120 VAC models have no cycle monitoring and are on off controlled by the user s external timer or PLC The minimum pause time requirements should be followed when setting up the external controller Optional low level control Operating Voltage 24 VDC 120 VAC 50 60 Hz Operating Current 24 VDC 1 0A 120 VAC 1 0A Operating Temperature 10 to 158 F 25 to 70 C Number of Outlets 6 8 12 or 18 Reservoir Capacity 61 in 1 0L Protection NEMA 4 Minimum Pause Time 4 min DC models 20 min AC models Maximum Operating Time 25 min DC models 15 min AC models Timer Memory Indefinite Maximum Operating Pressure 3000 psig 205 bar Output per Outlet amp Cycle approx 0 012 in approx 0 2 cm Lubricant up to NLGI 2 grease Weight 12 5 Ibs 5 7 kg Model Specifications Model No Valve Type Valve Mount P401 31401110 SSV6 24 VDC 650 40915 8 SSV8 120 VAC UL P401 61401110 SSV12 24 VDC 650 40915 9 SSV12 120 VAC UL P401 91401110 SSV18 24 VDC LINCOLN 16 aKF Quicklub Lubrication Systems LINCOLN Selection Guide VDC and VAC Pump Model 401 Pump Models P40100400114 Examples of part numbers P40162400154 P401 6 24 0 015 4 Pump 401 for grease an NG RR ER PENE TGA P401 d SSV Divider Block External SSV 6 SSV
40. n all automated systems LINCOLN 26 SKF Quicklub Lubrication Systems LINCOLN aa Fittings Adapters and Accessories Zerk Lock and Quicklinc Make Connecting Fast Quicklinc line connectors and adapters link metering valves and flexible lubrication lines Outlet adapters with check valves are used in automated systems while models without a check valve are used in manual systems called single point kits where a divider valve connected to several lubrication points is fed with a grease gun The Quicklinc tube splicer union is a great way to fix a broken line without replacing the whole line Just clean the line ends plug them into the connector and the line s repaired Quicklinc lube point connectors are ideal when fittings can be removed easily All three varieties straight 90 degree elbow and elbow swivel connect much faster than using a typical screw connector which requires assembly of four components Zerk Lock is Lincoln s other great time saving connector When removing a fitting is not practical the Zerk Lock grease fitting adapter is the answer It connects any 18 inch male tube adapter directly to a grease fitting Even when a fitting is self tapered or pressed in there s no need to drill it out and tap new threads with Zerk Lock a tremendous time saving Quicklinc and Zerk Lock are designed to work well together It s as simple as do wc KG 1 Install a Quicklinc 2 Place a Zerk Lock 3 S
41. n ties 50 count poly bag 7 177 8 m length 241054 Nylon ties 100 count poly bag 7 177 8 m length 274097 20 feet 6m of 34 convoluted loom split wrap 274098 20 feet 6m of 72 convoluted loom split wrap 274099 20 feet 6m of s convoluted loom split wrap Pump Mounting Bracket and Hardware for 203 Series and QLS 300 amp 400 Series Pumps Model T No 249520 Pump mounting bracket for 203 301 401 653 Series pumps 249209 12 mm x 172 long grade 8 bolt for 249520 pump bracket 2 required 274820 Pump and primary valve mounting bracket Stand Offs for Mounting SSV Valves P Clamps and Angle Iron Model Description No P 252807 Valve mounting block for welding 249987 6mm bolt to be used with the 252807 249850 12mm round stand off 270928 12mm square stand off 249848 12mm x long bolt to be used with 249850 and 270928 249851 10mm round stand off 249849 10mm x long bolt to be used with 249851 SKF 31 Quicklub Lubrication Systems LINCOLN Kits These kits are designed to service up to 12 points from a single grease fitting utilizing our 12 point SSV series divider valve The kits which are available with or without a grease gun include all componentry required to install the system Kits are available primed with NLGI 2 grease or non filled if a specific grade or type of grease is to be used These kits effectively replace the concept of using grease fittings mounted to a central manifold with a
42. newly enhanced stirring paddle in the reservoir to prevent grease separation even with long refill intervals All components including an internal pressure relief valve are part of the complete package Standard features include a built in controller with LED display and keypad for easy programming and monitoring and a divider block with 6 8 12 or 18 outlets The integrated all in one system concept reduces installation time and costs The 12 and 24 VDC models are available with bayonet quarter turn type plugs for improved protection in mobile applications optional low level control Operating Voltage 12 and 24 VDC 120 and 230 VAC 50 60 Hz Operating Current 12 VDC 2 0 A 24 VDC 1 0A 120 VAC 1 0A 230 VAC 0 5A Operating Temperature 13 to 158 F 25 to 70 C Number of Outlets 6 8 12 or 18 Reservoir Capacity 61 in 1 0L 2 0L Protection NEMA 4 Lubrication Cycle Time AC 20 min to 60 hours DC 4 min to 6 hours Number of Cycles For VDC 1 to 5 cycles For VAC SSV6 SSV8 1 to 3 cycles For SSV12 SSV18 1 cycle Timer Memory Indefinite Max Operating Pressure 3000 psig 205 bar Output per Outlet amp Cycle approx 0 012 in approx 0 2 cm Lubricant NLGI 2 grease Weight 12 5 Ibs 5 7 kg Model Specifications Model No Cable SKF 15 pus Quicklub Lubrication Systems LINCOLN Electric Grease Pumps QLS 401 Series QLS 401 for Remote Control The QLS 401 for Remote Control al
43. onnector with a tapered male thread This tapered to straight thread engagement is required for secure seal 247615 Staking tool for the 270784 Zerk Lock fitting a Swivels man 6 Model No Description II 91048 74 NPT male x NPT female 90 swivel 91308 14 NPT male x NPT female straight swivel Street Tee Description 276407 Ye NPT male x NPT female x NPT female Adapter Unions Model No 66649 Description 14 NPT male x NPT female swivel adapter union Installation Assembly Tools Model No 274062 Hand vise for quick connect and reusable hose ends 532 31847 1 Tool for Loosening Quickline Type Fittings 276424 Quicklub Spare Parts Kit LINCOLN 30 SKF Quicklub Lubrication Systems LINCOLN Fittings Adapters and Accessories Quick Wrap for Line Bundling and Protection Quick split wrap makes bundling and protecting lube lines fast It s as simple as 44 1 Place installation tool around group 2 Slide Quick Wrap onto line bundle of lines Approx Approx mog el Description rer ool Number of Number of i i Ya Tube 7s ID Hose 276389 54 Quick Wrap 164 roll 276634 276390 34 Quick Wrap 100 roll 276634 276391 1 Quick Wrap 65 roll 276635 System Finishing Accessories Model er 241110 Feed line bundling spiral wrap 10 ft 3 m length 241120 Feed line bundling spiral wrap 20 feet 6m of spiral wrap 276693 300 feet of spiral wrap 241055 Nylo
44. piston A fig 1 Lubricant flow shifts piston A from right to left dispensing lubricant through connecting passages to outlet 2 Flow is then directed against the right side of piston B fig 2 Piston B shifts from right to left dispensing lubricant through outlet 7 Lubricant flow is directed against the right side of piston C fig 3 Piston C shifts from right to left dispensing lubricant through outlet 5 Lubricant flow is directed against the right side of piston D Piston D shifts from right to left dispensing through outlet 3 Piston D s shift directs lubricant through a connecting passage to the left side of piston A fig 4 Lubricant flow against the left side of piston A begins the second half cycle which shifts pistons from left to right dispensing lubricant through outlets 1 8 6 and 4 of the divider valve Crossporting a Divider Valve Figure 5 Outputs from adjacent outlets may be combined by installing a closure plug in one or more outlets Lubricant from a plugged outlet is redirected to the next adjacent outlet in descending numerical order Outlets 1 and 2 must not be plugged since they have no cross port passage to the next adjacent outlet In figure 5 outlets 5 and 3 are cross ported and directed through outlet 1 In this example outlet 1 will dispense three times as much lubricant as outlet 7 The tube ferrules in outlets 1 and 7 block the cross port passage so that lubricant flow is only directed throug
45. r AC 94 265 VAC 47 63 HZ with 24 VDC motor Number of Connection Possibilities 1A 1 connector left power supply 1A 1 connector left power supply 1A 1 connector power supply left illuminated push button for additional lubrication low level 3 2A 2 connectors power supply left illuminated push button for additional lubrication low level right V10 V13 V20 V23 H 2A 2 connectors power supply left illuminated push button for additional lubrication low level left and piston detector right M08 M23 Type of Connection 1 square type connector DIN 43650 type A 5 bayonet plug 4 3 DIN 72585 1 V10 V13 V20 V23 H 6 bayonet plug 7 5 DIN 72585 13 M08 M23 7 bayonet plug 7 6 DIN 72585 1 V10 V13 V20 V23 Connection Outside the Pump 00 without socket outlet without cable 01 socket outlet without cable 10 socket outlet with 10 m cable 11 socket outlet with 10 m ADR cable 14 socket for bayonet with 10 m cable 4 3 V10 V13 V 20 V23 no low level no illuminated push button 15 socket for bayonet with 10 m cable 7 5 3 M08 M23 16 socket for bayonet with 10 m cable 7 6g V10 V13 V 20 V23 with low level or illuminated push button 17 2 socket for bayonet with 10 m ADR Cable 4 8 V10 V13 H P C B for 12 24 VDC V10 V13 adjustable pause and operating time 3 H for trailers and semi trailers
46. r Stroke Std 018 cu in 0 3 cc Std MET SU IH Din DE Std x 006 031 cu in Metering Plug 006 031 cu in 0 1 5 cc Optional 0 1 5 cc Optional Grease Reservoir 14 5 oz Volume Optional metering plugs are available for different output volume See Pump Output Adjustment chart below Pump Output Adjustment Metering Plug Model No Output per Stroke 271924 0 006 in 0 1 cm 271925 0 012 in 0 2 cm 271926 0 018 in 0 3 cm eum Costin LOSEM Note Standard plug included with pump LINCOLN 22 SKF Quicklub Lubrication Systems LINCOLN Hammer Pumps and Pump Accessories laa 203 Pumps Designed for Hammer Applications 271374 P203 4XNBO 1C7 24 1A1 10 No 7mm Chisel 4 No 7mm Chiset 4 No 7mm Chisel 4 No 4 No No a a No f 2 No a 12 No smsa a 2 No 8 24 No Ko No 273422 P2038XLB0 2K7242110 Yes No 2x7mm Su 273425 P2038XLB04K72428140 Yes No fmmsi o a Chisel paste compatibility must be confirmed by Lincoln technical Pump comes with 272634 kit installed for double output L 24 L 24 L 12 L 24 aL 24 8L 24 8L 24 203 Hammer Pump Accessories Model No 272634 274149 600 28750 1 274847 Push Button Switches 364 360705 664 36070 6 664340055 Wuminated Manual Swich Re 120 664340055 Iluminated Manual Switch Rea avoc 237133812 Replacement
47. rately Other technical data and dimensions are identical to the P203 SKF 13 pus Quicklub Lubrication Systems LINCOLN Electric Grease Pumps Reservoir Field Upgrades See ses Lidless Pump Upgrade Options Now available Retrofit kits to field replace current 4L and 8L Model 203 reservoirs to ones without lids The retrofit kit promotes good maintenance practice and improves system performance by eliminating grease contamination through the removable lid For each field retrofit kit two part numbers need to be ordered see model numbers below One part number for the reservoir One part number for the fixed paddle Assembly is required The fixed paddle snaps in place and the new reservoir gasket replaces the old one 444 70490 1 Fixed Paddle assy 4XNBO 4YNBO 544 32696 1 Reservoir 8XN BYN 444 70491 1 Fixed Paddle assy 8XNBO 8YNBO 544 32695 1 Reservoir 4XN 4YN Lidded Pump Upgrade Option These two kits are used to upgrade a 2 liter reservoir to either a 4 or 8 liter reservoir with lid pump These upgrades are for pumps without low level monitoring 544 32022 1 4 Liter Conversion Kit 544 32023 1 8 Liter Conversion Kit 15 Liter Upgrade Kit Converts 4 and 8 liter model Quicklub pump to 15 liter reservoir with low level 544 32957 2 4 and 8 Liter Conversion Kit LINCOLN 14 SKI Quicklub Lubrication Systems LINCOLN Electric Grease Pumps QLS 401 Series QLS 401 The QLS 401 features a
48. sive method of centralizing or automating the lubrication of machinery bearings Quicklub can be a simple centralized system with lubricant supplied manually from a lever gun Pre assembled kits are available to service up to 12 points from a single grease fitting Custom kits can also be provided by our distributors to cover virtually any quantity of points desired Quicklub lubrication method System Operation A Quicklub centralized lubrication 1 The lubricant is delivered to the system typically dispenses divider valves through a hand or measured amounts of lubricant air operated grease gun to each point covered by the sys tem Even those hard to reach are assured of being properly lubricated and purged of contaminants 2 The divider valve dispenses lubricant in measured amounts directly to each point being covered by the system through the feedlines Visual indication of S Oo TS Wo o UB cycle pin assures that all points COSS de nion ae are lubricated Quicklub can also be a fully automated system with lubricant supplied by our 12VDC and 24VDC electric or pneumatic pumps An automated lubrication system typically dispenses small measured amounts of lubricant at frequent intervals while production machines are operating The electric pumps incorporate an integrated timer for easy installation and trouble free operation Quicklub systems have proven to be the right solution for many
49. ts Catalog TUBING Hydraulic Steel Stainless Steel and Nylon Single and Multiple Tube Clamps Heavy Duty Standard Duty Threaded Sleeve and Snap On Coupler Tube Fittings Quicklinc Tubing Adapter Zerk Lock Grease Fitting Adapters Non Metallic PIPING Seamless Continuous Welded Forged Fittings Malleable Iron Fittings 316 Stainless Steel Pipe and Fittings Stainless Steel Fittings Galvanized Pipe Threaded Plug and Fittings ACCESSORIES Supply Feed and Bulk Feed Line Hose Air Hose Kits for Hose Repair Heavy Duty Air Line Quick Disconnects aKF AIR CONTROL AND ACCESSORIES Manual Shut Off Valves Pressure Gauges Lubricant Filters and Strainers AIRCARE AIR PREPARATION SYSTEMS Modular Air Line Filters Regulators and Lubricators Integrated Modular Filter Regulator with Gauge Modular Air Line Combination Units High Capacity Air Line Filters Regulators and Lubricators High Capacity Air Line Combination Units Miniature Air Line Components Air Line Filter Regulator and Lubricator Miniature Air Line Combination Units Modular Air Line Equipment Accessories Lockout Valve Quick Clamp Quick Clamp Wall Mounting Bracket Porting Block Quick Mount Pipe Adaptors Manifold Block Pressure Switch Panel Nut Wall Mount Bracket Tamper esistant Cover and Seal Wire Air Line Equipment Accessories Wall Mount Bracket High Capacity Mounting Bracket and Nut Miniature Pressure Gauges
50. y model valve SSV8 LINCOLN D noc aKF 5 Quicklub Lubrication Systems LINCOLN Divider Valves Va dia SSV D Metering Device SSV D metering devices are adjustable per outlet pair thus enabling lubricant requirements to be better met The metering occurs within the block via metering screws that are available in ten different outputs sold separately The outputs of the progressive metering device can be easily set even after installation Simply put in a different size metering screw Tedious reassembly of entire metering device segments is a thing of the past The SSV D can be integrated into system using standard SSV metering devices Both metering device types also use the same components such as piston detector and outlet closure plugs Specifications Construction Max Operating Output Outlet Pair Stroke Lubricant Lubricant 5 Operating Temperature Material Pressure cu in cc Inlet Outlet Carbon Steel 5076 psig 350 bar Min 0049 08 Max 110 1 8 Ys NPTF F M10x1 13 F to 158 F 25 C to 70 C Model No Maximum Number Cycle Indicator Pin Dimension A Number of Required of Outlets in mm Metering Screws 649 29535 1 2 75 70 3 649 29545 1 o mem o e 649 29536 1 3 35 85 4 649 29546 1 649 29537 1 3 94 100 5 649 29547 1 649 29538 1 649 29548 1 649 29549 1 649 29627 1 649 29635 1 649 29628 1 649 29636 1 649 29629 1 649 29697 1 ve m9 7 48 190 649 29630 1 o
51. y triggered lube cycles as well as the corresponding lubricant consumption Power supply interruptions The QuickData software is updated and all data can be read out by using an off the shelf infared IrDa to USB adapter All indications enable the users to draw their conclusions regarding the condition function reliability usability and duration of service of the machine or the device All information can be analyzed and documented and is then available as a written protocol The family of 233 pumps includes 12 and 24 VDC and 120 VAC pumps They are available with 1 2 or 3 elements in 5 6 or 7 mm or with an adjustable output element Reservoir sizes are 2 4 or 8 liters Refer to the pump identification code for a complete listing of available pump configurations Model Specifications Reservoir Reservoir Capacity Printed Low Level AE Model No Description circuit Liters Control board Ca E UE E UNE sione PzsrexBo ke2e2ws owpr z voc a 2a e ve edo PzsvextBo ke2ezws owor zsvoc e e 16 ves swsup P2334XL4K62424510M0F 2e voc 2 e ve usu Passeer avoc e s 1 ves sione P239 4XLG0 1K6 12 2A510 MDFA 12voC a 2 e Ves saos P239 8XL60 1K6 12 2A510 MDF A 12voC e e 35 Ves 644 40867 1 P233 8XLBO 1K6 AC 3A6 15 MDF 120VAC 8 48 16 Yes These pumps do not include a pressure relief valve or proximity switch which must be ordered sepa
52. ystems include Helios and Duo Matic two line systems and Centro Matic Modular Lube Quicklub and ORSCO precision oil lubrication With our BearingSaver program we find the best automatic solution for you from our wide range of systems for grease fluid grease and oil aKF General lubrication Sometimes a simple approach is the best solution Our wide range of products includes smaller self contained auto matic lubricators and general lubrication equipment Industrial pumping Lincoln has developed specialized pumps and pumping stations to handle the difficult job of transferring thick fluids From the industry best PileDriver Ill and PowerMaster lll pumps and air motors to specialty pumps controls and mounting accessories Lincoln is the preferred pumping system for many tough applications LINCOLN aay SKF is a registered trademark of the SKF Group Lincoln Quicklub Quicklinc BearingSaver Helios Centro Matic Modular Lube PileDriver Ill and PowerMaster Ill are registered trademarks of Lincoln Industrial Corp SKF Group 2014 The contents of this publication are the copyright of the publisher and may not be reproduced even extracts unless prior written per mission is granted Every care has been taken to ensure the accuracy of the information contained in this publication but no liability can be accepted for any loss or damage whether direct indirect or consequential arising out of the use of the
Download Pdf Manuals
Related Search
Related Contents
SHA・KC64E Honda Power Equipment GXI 60 Lawn Mower User Manual Bedieneinheit BE-SEG-01 Manual de instrucciones testo Saveris 21CFR Part 11 Software Copyright © All rights reserved.
Failed to retrieve file