1. 21 34b Ouibound edll a u ett mote enn HER 21 3 4 2 Incoming 22 3 4 3 Door Entry System with keyboard module SlimKey 22 PARAMETER PROGRAMM 23 4 1 PROGRAMMING WITH THE HELP OF A PHONE 23 4 1 1 Entry into the programming eese ener nennen 23 412 Parameter eene tenent nennen tenente 23 4 2 PROGRAMMING WITH THE HELP OF A PC PROGRAMME BRAVESET 24 DESCRIPTION OF PROGRAMMABLE 25 7 8 5 2 26 5 3 BASIC PARAMETERS toties in FR ARE SR 31 5 4 TIME PARAMETERS estin anaa nnns etit anna st nnne sensns ennt 33 5 5 SYSTEM PARAMETERS E AE 37 5 6 BASIC SETTING AND DELETION eene nnns 43 5 7 END OF PROGRAMMING 43 5 8 PARAMETER OVERVIEW eeeee einen tenens enne senes anganan test neis 44 TECHNICAL PARAMETERS 600000000000000000000000000 0000000000000000 0000000000 anane enenenen 47 6 1 ELECTRICAL PARAMETERS 2 ecececeeeceeeeencaeceeeeeseseeacaeeeeeeeeeeeesenaees 47 6 2 MECHANICAL DIMENSIONS nee nana aana anaa anana enne ntes 47 TABLE FOR EASY
2. 955 abd activation code from other modes of switch 0000 0000 1111 abcd Brave sends a serial code for the code relay COSW after evaluation code from other modes m of relay 1 30 BRAVE SlimDP User and service manual 5 3 Basic parameters Type of choice v time impulse 0 1 v type of choice v 0 is DTMF tone choice v 1 is impulse choice Parameter Value Bee z sign for prolonging a call or 10secs before the end of the call the Brave sends signal after pressing this the Brave prolongs the call Parameter Value Meaning Basic Command for disconnecting Brave from g Command order 1 2 there are 2 to disconnect the Brave from both relays bb Command for disconnecting the Brave from the phone 2 spaces is advantageous to set the same command for relay switching on parameter 35 36 and command for the Brave disconnection aazbb or 1 command is always 2 digits but if you wish to control relay with a single digit from the phone there is an option to input a where a is a single number and the star represents an empty space and must be in the first place e g at parameters 35 36 ooa Service password 0000 9999 0000 XXXX service password to programme from a phone DTMF A If you forget the password the following procedure is recommended 1 Open the Brave front cover 2 Switch DIP 2 to ON 3
3. Parameter Value Conditions Minimum line current 18mA Line picked up Minimum line voltage 18V Line disconnected Voltage on the line when Brave 8V 20mA picks up VA characteristic 12V 1 60 Lead in in disconnected state lt 30uA U 60V Impedance of line ending Wa 15nF Line picked up Bandwidth 300Hz 3400 Hz 20 60mA Impendence of ringing 2Kohm 25 60Hz Sensitivity of ringing detector min 10 25 V Impulse choice 40 60 ms Level of tone choice 6a 8dB 1 20 60mA Sensitivity of tone choice min 40 dB 20 60mA Sensitivity of tone detector min 30 dB 20 60mA Power supply for name tag back lighting relay heating and 12V DC 12V 24V 12V AC 10V 18V current circuit for exit button Max off take of backlighting and 250mA 12Vss heating Max Voltage of relay contact 48V When 1A Max Current of relay contact 1 5A When U 30V Operating temperature 20 to 60 st Level of cover IP44 1 Potential to change by programming 6 2 Mechanical dimensions Dimensions WxHxD 104mm x 153mm x 16mm Weight 360g Unit material elox aluminium profile Name card panel material acrylglas plexiglass BRAVE SlimDP User and service manual 47 7 Table for easy programming Fill in the values you want to programme into the empty part of the table in the double framed part there are whole programming commands to make programming easier You can keep the programmed values in the manual for future ch
4. User and service manual 5 4 Time parameters ee Number of rings before the Brave picks up 1 9 The number of rings before an incoming call is picked up The Brave picks up between rings 2 secs after detecting the q th ring It is possible to set the number of rings between 1 and 9 Parameter awe meaning Sese d The maximum length of time for which the Brave is busy lt is possible to prolong this time during the call by choosing a key or from the phone parameter 42 The setting of this time is in accordance with the adjacent table Parameter Value meaning eie w maximum time in seconds between button presses range 1 9 Normal buttons Relay switch on if the time between presses is longer than time w then the code will not work correctly Choice of number if the pressed button is the first number of a password to switch on a relay then the choice is delayed by time w Time of disconnection for repeat dialling 1 5 E z Time secs the Brave disconnects before it picks up again for repeat dialling press of a button during a call detection of busy tone range 1 BRAVE SlimDP User and service manual 33 E EOM Time before commencing a choice 1 5 z Time sec after the Brave picks up before it commences a choice range 1 5 This time is different for each switchboard phone system but generally most operate within 2 seco
5. e The product in question e description of the problem e Proof of purchase and e Your full name and address The warranty does not cover e Mechanical chemical thermal or any other faults cause by the user e Faults caused by natural disasters e Faults caused by repairs or changes made by the user or any other authorised or unauthorised person s e Purposely done damage e Incorrect use of the product caused by incorrect installation programming etc and e Damages cause during the transport of the product to and from the purchaser Manufacturer Dealer Date of sale 8 Drilling master board ALPHA Tech JR 2013 Version 2 6 X 13
6. Brave doesn t produce acoustic feedback In the Hands Free circuit there are several functioning blocks for supressing this feedback The basic one is a circuit for semi duplex operation where the incoming signal weakens the microphone and the signal from the microphone weakens the incoming signal Thresholds for switching on the microphone are set in this parameter the lower the value the higher the sensitivity of the microphone In noisy surroundings it is recommended to use a higher value with combination of parameters 71 75 77 77 Speed of switching over voice atomisation 2 1 4 4 is the slowest Parameters 75 76 describes the principle of acoustic feedback and the speed with which the circuit switches over the quality of incoming or outgoing sounds are set with parameter 77 Switchover time ms 1 2 4 8 VA characteristic for line connection 0 1 Nearly every country in the world has different telephone norms and this parameter enables you to lower the voltage on the Brave s terminals to connect telephone line voltages in active state by 1V Where it is required the respective norm lowers line voltage by 1V as standard it is Iz1 BRAVE SlimDP User and service manual 41 Compensation for loss of conduit depending on 79 line current 0 1 2 The Brave has a circuit for installations remote from the TETTE 100m that can compensate for the loss caused by a conduit This
7. Call the Brave 4 Once the Brave picks up the system is in programming regime In this regime it is possible to change the password 44xxxx Switch DIP 2 to OFF and Close the front cover own BRAVE SlimDP User and service manual 31 Parameter Vae meaning fee Command for switch over to DAY 11 00 99 0 9 Command for switchover to NIGHT 10 0099 0 9 command to switch over to the DAY regime 2 spaces n command to switch over to the NIGHT regime 2 spaces f command is always 2 digits but if you wish to switch over from Day to Night with a single digit from the phone there is an option to input a where a is a single number and the star represents an empty space and must be in the first place e g parameters 35 36 Note The Day Night switch over regime stays set following line disconnection Parameter Bee e Choice of regime numbers 0 selects numbers from first and second group ez1 selects numbers in accordance with the Day Night regime WARNING setting this parameter materially affects the number dialling Parameter Value Line disconnection function by repeatedly pressing a button 0 1 k Line disconnection by repeated pressing of the same number k 0 function is disabled and kz1 repeatedly pressing the same button to disconnect the line A WARNING setting of this parameter materially affects number dialling 32 BRAVE SlimDP
8. Parameter Value COTE signals introduction conclusion 0 1 2 The acoustic signals for the connection and disconnection of a line are standard but this may cause false choices with some phone systems So using parameter v itis possible to switch off these signals The values required are z 0 Introduction conclusion signalisation is off z 1 Pick up and disconnection signalisation on intro concl type1 z 2 Pick up and disconnection signalisation on intro concl type2 Parameter Value E a Acoustic ticking signal during a call EM 0 1 Ticking during a call is switched off as standard However by switching it on you can differentiate on the switchboard a call from the Brave by a faint ticking The values are u 0 Ticking into a call is off u 1 Ticking into a call is on E RE 7 Acoustic signals for switching on a relay 0 1 The signal for switching on a relay is standard z 0 However it is possible to use this function when using a uni directional supply 12V so when the door lock is open there is no buzzing so the person at the door won t know the door is open When set to zz1 the time the relay is switched door open then there is a specific sound Note This function is available only for regimes mz1 Note2 During the relay switch on 2 impulses there is acoustic signal for the whole time of the sequence even during gap between impulses BRAVE SlimDP User and service manual 37 Parame
9. basic models Brave SlimDP 01 1 button Brave SlimDP 02 2 buttons Brave SlimDP 04 4 buttons Parameters that are not specified in this manual is not recommended to change because they are not available for the version of Brave SlimDP If you do happen to change a parameter so it is recommended to make the defaults parameters 1 4 Unit features Three versions are available plus keyboard Brave SlimDP 01 Brave SlimDP 02 Brave SlimDP 04 Keyboard Canopy 8 BRAVE SlimDP User and service manual 2 Installation This compact unit is fixed by 2 screws to the wall 2 1 Opening wiring wall mounting and settings 2 1 1 Name card panel 1 2 1 2 Uncover control elements 4 Push the aluminium speaker grille down see Every unit is supplied with a special key which is used to release the name cards on the front panel Push the key into the hole in the speaker grille see figure 1 Push the name card panel down and then push it towards to grille see figure 2 The panel will be released Pull it towards you to remove see figure 3 figure 4 BRAVE SlimDP User and service manual 2 1 3 Wiring and wall mounting 5 Use the wall mounting template at the end of the manual to mark the position for the screw holes and cable connection the mounting surface Drill the holes 6 Feed the cable analogue line power supply lock see figure 6 thro
10. higher N Under no circumstances use 120V or 230V direct current DC This can be solved by the use of contactors power relays BRAVE SlimDP User and service manual 11 8 2 1 4 Switches The switch marked HEAT see figure 8 activates heating of the PCB This is for increased resistance against humidity To use this feature you must connect an external 12V power supply The switch marked SERVICE see figure 9 is required for programming the unit when the password is forgotten It is performed by ordinary phone DTMF tone dial on The switch is off The PCB heating has two major benefits Firstly it warms the board during winter time temperatures under 20 C most circuits have warranty operation down to 20 C and secondly it helps to protect the PCB against humidity when installed outside A Note Door entry system Brave SlimDP is designed in such a way that it is possible to connect 10 18V AC or 12 24V DC to the terminals 12V polarity is unimportant The motherboard heating system has a regulator so that resistors won t burn out at a higher voltage 12 BRAVE SlimDP User and service manual 2 1 5 Voice level The principle of setting acoustic paths Here we have three parameters 71 72 and 73 Using the interaction of these parameters can be set to sound in different conditions 1 quiet environment parameters 71 72 73 are set to 7 2 environment where is a stro
11. on 0 1 66 Suppression of reception DTMF from microphone 0 1 BRAVE SlimDP User and service manual 45 67 b Baby Call call without the need to programme in number 0 1 0 68 b Mute at the lock activated 0 1 0 5 Setting of number of buttons on the main 2 panel 6 t Delayed start for switchboards with line 0 tests Siemens 0 1 Reception volume 01 16 16 is the highest SPK Transmission volume 01 16 16 is the highest MIC Speaker volume 01 16 16 is the highest TRH Soft transition of switchover 0 1 Suppression of background noise 0 1 Threshold for switching on the microphone 1 4 4 is the highest Speed of switching over voice atomisation 1 4 is the slowest VA characteristic for line connection 0 1 Compensation for loss of conduit depending on line current 0 1 2 Level of signalisation transmission in dBm 04 16 Basic setting provide Deletes all numbers in 1st group regime Day Deletes all numbers in 2nd group regime night Basic setting only for parameters 3x Basic setting only for parameters 4x Basic setting only for parameters 5x Basic setting only for parameters 6x Basic setting only for parameters 7x 46 BRAVE SlimDP User and service manual 6 Technical parameters 6 1 Electrical parameters
12. panel This constant serves a purpose to identify the no 1 button in the composition of the module After entering the number of buttons s the button no 1 is moving so it is always first Number of buttons on the main panel s choice 1 1 2 2 4 4 WARNING setting this parameter materially affects number dialling Pase aue Weg ao Delayed start for switchboards with line testing Siemens 0 1 This function is off as standard t 0 By switching this function on t 1 the processor goes into sleep mode immediately after the line connection and after 3 secs The Brave initialises The line connection after the power supply connection is then delayed state switching on restarting of the switchboard If this function is not working and the telephone switchboard still identifies a line fault then there is no other option but to use e BestBox external module e mudule SlimKeyboard include permanent power doorphone from 12V BRAVE SlimDP User and service manual 39 5 6 Parameter setting Hands Free A First ensure that the rubber seal on the microphone fits properly otherwise setting the acoustic parameters will be difficult Parameter Value Meaning Basic 71 Reception volume 01 16 16 is the highest SPK 07 Transmission volume 01 16 16 is the highest MIC Speaker volume 01 16 16 is the highest TRH gg ff rr Each number is entered as 2 digits with a range 01 16 After receiving a con
13. 2 Switch on r 2 from phone lt On keyboard option 1 impulse 352 2 Switch on r 1 from phone 2 impulses 361 2 Pd of time for r 1 switch sec 371 2 Control of r 1 during incoming call 149 381 Control of r 2 during incoming call 1 0 382 i Length of time between impulses of r 1 sec 301 2 Enable code relay COSW sw 1 0 1 3 0 1 code for activation 1 imp btn 0000 1111 3 1 4 code for activation 1 imp phn 0000 1111 3 2 4 code for activation 2 imp btn 0000 1111 3 3 4 code for activation 2 imp phn 0000 1111 3 4 4 code for activation other mode 0000 1111 3 5 4 Type of choice tone imp 0 1 1 Sign for prolonging of call 1 Brave disconnection from x phone Doe Brave disconnection from 5 phone 009 Service password 0000 9999 4 Command for switch over A to DAY 90 9 s Command for switch over to NIGHT 0073 2 Regime system choice 1 0 1 Disconnection by repeat 0 1 1 press of the same button Number of rings for pick up 1 0 51 1 Maximum length of time min 52 1 Time between button presses sec 53 1 Time of disconnection for repeat choice 54 Time before choice sec 55 1 commences Number of rings before disconnection 04 99 56 BRAVE SlimDP User and service manual 49 Frequency of tone detector table 500 1 Number of busy tones 4 0 501 1 Length of time of 1 5 502 permanent tone Length of time of tone sed 1 choice nn x 10 503 2 Gap between DTMF
14. Brave Door Entry System Brave SlimDP 01 Brave SlimDP 02 Brave SlimDP 04 User and Service Manual Version 2 6 Welcome Congratulation on purchasing the Brave SlimDP BRAVE Slim Door Phone which is a continuation of the successful SlimDP Slim Door Phone The Brave SlimDP is a universal project with the title BRAVE with different designs bringing a wider spectrum of functions and possibilities This manual is for the following options Brave SlimDP 01 1 button Brave SlimDP 02 2 buttons Brave SlimDP 04 4 buttons Basic functions of the new line Electronic volume control without the need to open the front cover Programmable tone detection for call disconnection or repeat calls Programming with a DTMF phone or USB cable from a PC 24 digit telephone numbers including Flash and Pause LED backlit name tags Manual Version V2 6 22 10 2013 fl L P H Alphatech spol s r o Jeremenkova 88 140 00 Praha 4 Tech Tel fax 272103334 www alphatech cz info alphatech cz Table of Contents 1 5 BASIC FEATURES 4 e na enses teens tatu anake nia sapaa NANA 6 1 1 stulti 6 1 2 TERMINOLOGY e Let et ees 7 1 3 BRAVE SLIMDP VERSIONS AND 8 1 4 UNIT FEATURES tc pot eain 8 INSTALLATION 5596 495359868
15. N9 aeta sna tasto senses sos ana 96 855 etos tns t esso aaoi 9 2 1 OPENING WIRING WALL MOUNTING AND SETTINGS 9 DAA card paliel s iet Hom Pa ete EEEE TRS 9 2 1 2 Uncover control elements 9 2 1 3 Wiring and wall mounting 10 2l 4 7 3SSWICheS a cs on REPRE edo 12 DAD Voice CVE s a e rte dar a em p RE RR set een 13 2 2 LOCATION OF DOORPHONE COMPONENTS 14 2 9 CHANGING NAME CARDS opea nien 15 2 4 FINAL CLOSING OF DOORPHONE ccce enne nennen nennen nenne 15 2 4 1 Covering control elements eese eene 15 2 4 0 Replacing name card panel eese 15 2 5 KEYBOARD 16 2 6 CODE RELAY entente enne nnne nnne nent 17 2 7 9 eti Reha tic pras gor t ada ra 18 2 015 ImeRelaysuussseeute priae eite 18 2 7 2 Power supply I2V AC i ise er eee pee te eet 18 2 73 Powersupply 12V DC sisa tag wig ag ana Rec er 18 2 74 USB Programming cable eese 18 DOOR ENTRY SYSTEM OPERATION 19 3 1 SIGNALLING OVERVIEW 19 3 2 GALLER AT THE DOOR wi ee tiet retard inel tae e etu erento 20 3 3 RELAYS REGIMES aba teuer 21 3 4 PERSON IN THE
16. PROGRAMMING 66000000000000000000000000 0000000000 anane enananenen 48 DRILLING MASTER BOARD 66000000000000000000 0000000000000000 00000000 ao enses sosta 52 BRAVE SlimDP User and service manual 5 1 Basic features 1 1 Features VNN VNN VVVVV v Voice communication is powered from a telephone line Impulse and tone DTMF options Storage of 2 24 digit long numbers per button including Flash and pause Option to prolong a call with or Option to connect one electronic locks to open doors Potential to use up to 6 relay regimes for electrical lock an additional bell lighting etc Two codes to disconnect the Door Entry System from a phone One code to open doors from the phone for 1 impulse and one code for 2 impulse 3 x 6 code locks for relay password from door buttons Can be connected electrically secure lock on the switch serial activation code COSW Option to disconnect a call by the repeated pressing of a button Option to switch on a baby call regime no number dialling Option to switch on a regime to suppress the DTMF connection from the microphone Option to switch on a ticking sound into a call to announce another call Option to switch on acoustic signalling for relay connection Option to set the number of rings before connecting a call Programmable parameters for tone options Flash length and Pause length Programmable parameters for acoustic sign
17. alisation Programmable parameters for tone detection Electronic volume setting without the need to open the front cover Version A is with integrated 1W amplifier Programmable with PC via USB cable and remote DTMF programming Integrated regulated heating of the PCB BRAVE SlimDP User and service manual 1 2 Terminology Telephone line Line connection Line disconnection Option Incoming call Outbound call Call connection Code lock Code relay External code Internal code AN Analogue 2 conductors connecting to a public telephone network public line or to a local telephone system local line The start of a telephone connection the same as picking up a phone handset End of connection the same as replacing a phone handset DTMF a tone option combination of two tones chooses also special signs and uses breaking the loop Flash Impulsive option by breaking the loop chooses only digits Connection between a Brave and a phone made by selecting an option on the phone The Brave connects the call after set number of rings The Brave can be programmed from the phone following a connection by inputting a password Connection between the Brave and a phone made by choosing an option on the Brave i e Pressing a button Signalised when following the dialled number is picked up This signal is not available on an analogue line but the ringing tone ends and a connection begins It is difficult to ide
18. anges Meaning Programming sequence description specify par Fill the values Number under button 1 Day 1gr Number under button 2 Day 1gr Number under button Day 1gr Number under button 4 Day 1gr Number under button 1 Night 2gr Number under button 2 Night 2gr Number under button 3 Night 2gr Number under button 4 Night 2gr Relay 1 works in mode 1 6 311 1 Passw for relay 1 1 imp Day Night 3211 6 Passw for relay 1 1 imp Day Night 3212 6 Passw for relay 1 1 imp Day Night 3213 6 Passw for relay 1 1 imp Day Night 13214 6 Passw for relay 1 1 imp Day Night 3215 6 Passw for relay 1 2imp Day Night 324 6 Passw for relay 1 1 imp Day 3311 6 Passw for relay 1 1 imp Day 3312 6 Passw for relay 1 1 imp Day 3313 6 Passw for relay 1 1 imp Day 3314 6 Passw for relay 1 1 imp Day 3315 6 Passw for relay 1 2 imp Day 331 6 Passw for relay 1 1 imp Night 3411 6 Passw for relay 1 1 imp Night 3412 6 Passw for relay 1 1 imp Night 3413 6 Passw for relay 1 1 imp Night 3414 6 Passw for relay 1 1 imp Night 3415 6 Passw for relay 1 2 imp Night 341 6 48 BRAVE SlimDP User and service manual Button choice for 1 relay m 6 311 2 Switch on r 1 from phone 1 impulse 351
19. ap between DTMF tone choices is specified by the formulae the entered number x 10 time length of gap ms range 04 16 which is 40 160ms f Length of flash is specified by the formulae the entered number x 100 z time length Flash ms range 1 6 which is 100 600ms p Length of pause is specified by the formulae the entered number x 100 400 time length of pause ms range 1 0 which is 500 1400ms Time p is the simultaneously length of gap between button taps for an impulse choice Parameter Value LI level of DTMF choice v dBm 04 16 uu Transmission level of DTMF choice to the line the range is 4 to 16dBm input the de level where uu 04 is 4dBm uu 10 is 10dBm BRAVE SlimDP User and service manual 35 36 509 S Listening in DTMF level 1 4 p Preemphase is the ratio of the upper and lower groups of DTMF frequencies It is possible to choose ratio 2 2 dB 0 Europe or ratio 3 2dB p 1 Australia 5 Choice of DTMF volume levels 4 levels Volume in DTMF dB S choice 15 1 9 2 3 3 3 4 BRAVE SlimDP User and service manual 5 5 System parameters Parameter Value Acoustic signals confirmation error empty memory end of call 0 1 The Brave s comes with standard acoustic signals However using parameter z itis possible to switch off the acoustic signals The values z 0 Acoustic signals off and z 1 Acoustic signals on
20. be a programming entry tone followed immediately by a programming tone see chapter 3 1 page 19 2 With the help of DIP 1 SERVICE incoming call only connect to the Brave as in part 1 above but where the DIP switch is in position 1 the Brave will go straight to the programming regime you will hear the pick up tone for entry to programming followed immediately by the programming tone see chapter 3 1 page 19 Do not forget to put DIP switch to position off at the end 4 1 2 Parameter programming The default state for programming is announced with a programming tone the Brave always returns to this state after a specified time bsec whether you started programming or not There are two types of parameters used during programming These are parameters with a fixed length which is the majority of them when programming is confirmed after it fulfils the mandatory length and is immediately written in with a confirming tone and parameters with variable length parameters 1 2 32 33 34 when the confirmation is made only after time of inaction 5 sec The only case when there is an immediate writing in of parameters is when the maximum number of written in signs numbers are filled up for parameters 1 and 2 it is 24 for parameters 32 33 34 it is 6 If you input a number sign that is unacceptable during the programming the Brave immediately sends an error tone the parameter is not written in and the Bra
21. d the programme is indicated by the firmware on the bottom For ease of orientation the parameters in the BraveSet programme are marked with the same codes as per the phone programming The details about parameter setting can be found in help of the programme and also on the manufacturer s website www alphatech cz 24 BRAVE SlimDP User and service manual 5 Description of programmable parameters Parameters always start with a fixed mandatory part address followed by a variable part which is your choice The range and explanation is always under the table sometimes with examples Everything is dialled exactly as it is shown in the table nothing needs to be confirmed in any way after writing into a memory a confirmation tone can be heard and if an incorrect value is input then an error tone will be heard 5 1 Direct dialling memory tt button number memory always input 2 digits 01 04 nn telephone number as long as 24 digits that are to be saved For saving of other sign choices always use the meaning choice assignation as per the table 0 9 0 9 Numbers saved in parameter 1 are numbers of the first group or numbers of the regime Day t Basic settings never change or delete these saved Flash numbers Pause 0 tt button number memory always input 2 digits 01 04 nn telephone number as long as 24 digits that are to be saved For saving o
22. e 12V for relay light and heating Telephone line connection Microphone 14 BRAVE SlimDP User and service manual 2 3 Changing name cards Name card panel 2 1 10n page 9 has spaces to insert printed name cards Insert name cards from top see picture Cards can easily be printed with pictures as well as text using the included software The card outline is marked for easy cutting Panel with cards 2 4 Final closing of Doorphone 2 4 1 Covering control elements 1 Push aluminium speaker cover back up see picture Take care when re covering the speaker The aluminium edge of the speaker may be gently pressed if required 2 4 2 Replacing name card panel 2 Push key into hole in speaker grille as far as possible see figure 2 3 Push name card panel upwards and push the bottom edge in see figure 9 4 Push the name card panel back g down behind the lip of the casing 2 see figure 4 BRAVE SlimDP User and service manual 2 5 Connect the Keyboard Keyboard work as separate code lock he has connection power supply 12V input for departure button and one relay with change over contact In case connection by special cable keyboard with Doorphone characteristics those code lock expand and keyboard can be use not only to control relay in keyboard but relay in doorphone Doorphone contol too and use so 10 codes for one and 10 codes for second relay Fu
23. external 1 impulse for length of time t1 use for electric locks or 2 impulses when it switches on for time t1 off for t2 and again switches on for t1 opening of sliding gates mz2 is switched on for time when the line is picked up camera switches on when system picks up and off when it disconnects mz3 is switched on for time when the line is picked up and extra time t1 after disconnection lights switches on for time when the line is picked up and extra time t1 after disconnection for this time the line is busy mz4 regime button switched on when any button is pressed and off after t1 use is for example connection of external bell or siren mz6 switches on depending on pressed button it is set in parameter 31r In this way it is possible to choose only one button for each relay which when pressed switches on relay for time t1 This regime is used instead of connecting separate doorbell to the system Parameter Value button tt switches on LT C NEN rin regime m Bue 01 04 relay number relay number 1 in SlimDP i button number memory always in two digits 01 99 This parameter is only for relay regime m 6 Value tt determines which button starts switching on for time t1 of relay r 26 BRAVE SlimDP User and service manual Parameter Meaning In regime Day Night password hh for relay r in order p 1 5 for 1 impulse and p for 2 impulses 11 444444 In regime Day password hh for
24. f other sign choices always use the meaning choice assignation as per the table 0 9 0 9 Numbers saved in parameter 2 are numbers of the second group or numbers of the regime Night Di Basic setting never change or delete these saved Flash numbers Pause 0 Note The Day Night regime switch over remains set in the Brave even after a line disconnection Examples of setting 1 first button is supposed to dial 358 during the day and 0603441296 during the night then the programming is 101358 and wait for then 2010 0 603441296 and wit for 2 second button is supposed to dial 123 1 2Flash3 during day and night then the programming is 1021231 2 3 and wait for then 20212381 2 3 and wait for BRAVE SlimDP User and service manual 25 Note f you are not using regime Day night or regime 2 groups of numbers then it is recommended to set regime Day Night parameter 47 and then set the same code for switching over Day Night parameters 45 and 46 His way it is guaranteed that Brave will always be in Day regime and you can only programme telephone numbers for the day regime parameter 1 5 2 Relays O a frm relay r operates in regime m 1 8 11 21 r relay number 1 in SlimDP m relay regime 1 6 not m 5 regimes mz1 4 5 6 are explained in detail in Relay Regimes Tab 1 on page 21 1 mode relay switched on with command internal code or with a password
25. firmation tone JJ the new value is immediately active and can be tested Facilitation you can also add reduce the volume with help of buttons on the phone and 5117 Stops for the maximum and minimum volume are acoustically signalled 3 tones like the signal for the end of a call If you don t press anything for 5 seconds then the set value is saved and you hear a confirmation tone WARNING Default values are set by the manufacturer and it is not recommended that you change them unless absolutely necessary o Soft transition of switch over 0 1 This function is set to off as standard c 0 it is a character of the semi duplex operation switch over on the telephone line If the character of silencing is too steep it is possible to soften it using cz1 75 n Suppression of background noise 0 1 This function is set to off as standard 0 the Brave is installed in noisy location train station busy street car park etc by switching on this circuit nz1 the noise level is set as a default threshold for switching on the microphone and is not one way opened This is related to setting of parameters 71 76 77 40 BRAVE SlimDP User and service manual Parameter Value Meaning Sese 76 Threshold for switching on the microphone 2 1 4 4 is the highest There is a simultaneous signal from the microphone and the speaker on the telephone line to ensure that the
26. function is switched off as standard k 0 but it is possible to set on 2 levels depending on the current that switchboard can supply short circuit current lo Switchboard current lo Function off 20mA 50mA 45mA 75mA 70 Level of signal transmission v dBm 04 16 uu The signal transmission range to the line is 4 to 16dBm entered is required level which is uu 04 is 4dBm uu 10 is 10dBm 42 BRAVE SlimDP User and service manual 5 7 Basic setting and deletion Parameter Value Meaning Basic 8 Basic setting provide This setting does not affect parameters 1 and 2 numbers saved in memory Parameter Value Meaning Basic 81 Deletes all numbers in 1st group regime Day 82 Deletes all numbers in 2nd group regime night 83 Basic setting only for parameters 3x only 3 84 Basic setting only for parameters 4x only 4 85 Basic setting only for parameters 5x only 5 8 i i 28 6 Basic setting only for parameters 6x only 6 87 Basic setting only for parameters 7x only 7 Parameters 81 and 82 deletes all numbers saved in the button memory Parameters 83 87 deletes selective basic setting for parameters starting with 3 4 5 6 7 Values for the basic setting are stated for each parameter in the right hand column Basic WARNING deletion is irreversible and it would be necessary to reprogramme them again 5 8 End of programming Paramet After choosing 9 pro
27. gramming tone the Brave disconnects BRAVE SlimDP User and service manual 43 5 9 Parameter overview Parameter Meaning number nn under button tt number nn under button tt relay r works in regime m 1 6 button tt causes switching on of relay r in regime m 6 01 04 In regime DAY NIGHT password hh for relay in order p 1 5 for 1 impulse and p for 2 impulses 11 444444 In regime DAY password hh for relay r in order p 1 5 for 1 impulse and p for 2 impulses 11 444444 In regime NIGHT password hh for relay in order p 1 5 for 1 impulse and for 2 impulses 11 444444 command aa from the phone for switching on relay 1 impulse 00 99 0 29 199 266 command aa from the phone for switching on relay r 2 impulses 00 99 0 9 time ss sec of relay r switch on for time ti 01 99 Control of relay r during incoming call 0 1 period zz sec between impulses for switching on 2 impulses of relay r time 105 205 length t2 01 99 p 1 enabled disabled p 0 connection code relay COSW 0 1 activation code 1 pulse from buttons 0000 1111 activation code 1 pulse from phone 0000 1111 activation code 2 pulses from buttons 0000 1111 activation code 2 pulses from phone 0000 1111 activation code from other modes of switch 150 260 105 205 11 21 41 Type of choice v ton impulse 0 1 0 42 2 Sign for call
28. is set in several codes to activate the relay code Relay can be activated codes for one or two impulses can differentiate activated from the phone DTMF or from keys keyboard The last option is 0 the activation code in another mode switch than the lock The code information is 8 bits but the code is 4 bits with security 4 bits which is total of 8 bits Practically this is performed so that after activation the switch is first transmits the serial code and if they agree so code relay connects the electric lock ss s 5 NO COM NC NO 12V The code relays can be connected in parallel to increase the number of switches but can never combine connections electric lock and the code relay parallel BRAVE SlimDP User and service manual 17 18 2 7 Other accessories 2 7 1 Time Relay The time relay enables wider functionality of the relays It is a separate product and detailed instructions be found at au www alphatech cz wine A GEER AMER 1234 1554 2 7 2 Power supply 12V AC A 12V 1A AC alternative power supply is recommended for the Brave SlimDP normal version This is not a part of delivery and must be ordered separately Further details of power supplies and electric locks can be found at www alphatech cz 2 7 3 Power supply 12V DC A 12V 1A DC alternative power supply is recommended for the Brave SlimDP version with amplifier This is not a pa
29. mber relay number 1 in SlimDP 2 in Slimey zz timet2 between first and second impulse for switching on relay 1 2 spaces 00 99 where time 00 means 0 5sec E RERO 1 enabled disabled p 0 connection code relay COSW 0 1 turns on transmission serial code to activate the first relay CAUTION at activation this function never connect to the circuit electric lock without board COSW code relay threatens to destroy the relay in Brave communicator The following codes may be the same or different for the resolution switching on multiple parallel connected relay code Parametr Vae Description porat activation code 1 pulse from abcd Brave sends a serial code for the sae TN COSW after evaluation code from keys keyboard namely for 1 pulse BRAVE SlimDP User and service manual 29 Paramon Vale Description activation code 1 pulse from P o abcd Brave sends a serial code for the TT ey COSW after evaluation code from telephone DTMF namely for 1 pulse Parametr Value Description perm activation code 2 pulses from Goo abcd Brave sends a serial code for the TT a COSW after evaluation code from keys keyboard namely for 2 pulses Parametr Value activation code 2 pulses from abcd Brave sends a serial code for the TT COSW after evaluation code from telephone DTMF namely for 2 pulses Paramor Value
30. mmand for switching on 1 relay 1 impulse is for example 8 the command for disconnection is 8 and the command for switching on 1 relays 2 impulses is 9 Programming 351 8 JJ 431 8 361 9 If you are in conversation with the Brave the command to open a gate would be button 9 the first impulse starts and the gate opens the second impulse stops it the time the gate is opened opened space is set by time between the impulses parameter 30 after people enter press 8 then Brave makes 1 impulse and disconnects gate closes Parameter Value NL LL time ss sec of relay r on for time t1 105 205 relay number relay number 1 in SlimDP ss time t1 for which relay 1 is switched on 2 spaces 00 99 where time 00 means 0 5sec 28 BRAVE SlimDP User and service manual relay r control during incoming call 0 1 11 21 relay number relay number 1 in SlimDP S parameter whether it is allowed pz1 or disallowed 0 to control relay during incoming call To prohibit control during an incoming call for use with relay 2 in mode 1 for controlling a garage door so the electronics open the garage door and the car passing through the door closes the door Then control from the phone could result in a permanently opened door i e the door doesn t close because car didn t enter time zz sec between impulses for switching on relay r 2 impulses time t2 105 205 01 99 relay nu
31. nds after a line is picked up Parameter value Meaning Number of rings before it disconnects 12 04 99 After the choice finishes it will start counting CRT control ringing tones if the number is higher than hh then it will disconnect range 04 99 repeats the choice if the regime of dialling 2 groups of numbers is set Parameter Value Meaning Basic 500 Medium frequency of tone detector 1 0 Number of busy tones 2 0 Time length of permanent tone 1 5 3 3s x Medium frequency of tone detector is set if there is a non standard signal from the telephone switchboard y Minimum number of busy tones necessary for detection 2 0 where 0 means 10 busy tones z Minimum length of time of a permanent tone for detection of notification tone at branch switchboard 1 5 sec frequency x choice Hz 275 375 325 425 375 475 425 525 475 575 525 625 575 675 625 725 675 775 725 825 ojojo NID 34 BRAVE SlimDP User and service manual Parameter Meaning Basic 503 Tone length of time for DTMF tone choice 04 16 504 Time of gap between DTMF tones n 10 100ms Length of flash time 100ms 506 Length of time of pause digit gap 1 0 4 800ms 10 100ms tt Length of DTFM tone choices is specified by the formulae the entered number x 10 time length of tone ms range 04 16 which is 40 160ms m Length of g
32. ne inside of the building rings and on pick up it is possible to talk to the visitor at the door By choosing a code it is possible to switch on a relay parameter 35 if it is set in mode m 1 switch over the Day Night regime parameter 45 46 and disconnect the connection parameter 43 10sec before the end of the call parameter 52 the system BRAVE SlimDP User and service manual 21 sends a notice about the end of the call but choosing a code parameter 42 it is possible to pro long the call By replacing the handset the call is terminated the switchboard phone will send a system busy tone and the system will disconnect There is one more option disconnection of line after repeat pressing of the same button parameter 4 3 4 2 Incoming call An incoming call is a call to the system started by a person inside the building After choosing the branch the system is connected and the line rings following a set number of rings parameter 51 the system will then pick up and it is possible to speak The options are the same as an outgoing call chapter 21 e One exception is in the first 10sec when it is also possible to input and a service password parameter 44 directing the system to go to the programming regime e Another exception is during incoming call and DIP1 is switched to on SERVIS when the system also goes to the programming regime without a service password e The final exception is relay controls parame
33. ng ambient noise at the communicator and quiet environment at the phone Here is both necessary to reduce the microphone gain parameter 72 1 3 and also change the ratio of the parameters 71 73 way 73 enlarge the the parameter parameter 73 11 15 and 71 parameter smaller value 71 2 4 3 environment where is a strong ambient noise at the phone and quiet environment at the communicator Here we leave the parameter value of 72 7 and 73 and 71 parameters set as follows parameter71 11 to 14 and 7322104 The principle of settin parameters is signal from the microphone is amplified by the sum of parameters 72 71 volume of microphone and signal to the speaker is amplified by the sum of parameters 71473 volume of speaker To switch the direction of the ratio is evaluated parameters threshold 73 72 f parameter 72 is greater than the parameter 73 thus favoring the direction from the microphone We choose when the direction to the phone is interrupted f parameter 73 greater than parameter 72 thus favored direction to the speaker We choose this if the interrupted sound in the speaker of communicator BRAVE SlimDP User and service manual 13 2 2 Location of Doorphone components All mounting control and setting elements are located under the speaker front aluminium grille oudspeaker J Heating activation lighting Ag EE SlimDoorPhone fixing screw hol
34. nnects Relays can switch on one or two impulses depending on control code with the length of time between impulses set in parameter 30 See Tab 1 20 BRAVE SlimDP User and service manual 3 3 Relays regimes Regime m 1 parameter 3111 and 3121 Action Note Parameter Relay Evaluation of correct 3211 3215 internal code from According to setting 3311 3315 1 the buttons Day Night 3411 3415 321 According to setting 331 1 t2 E Day Night 341 Internal code from Option to choose 1 or 2 351 t the phone digits of code 1 2 digit code is basic and it is possible to shorten it by using in the first 361 MAH place of code during 1 a programming Regime mz4 Action Note Parameter Relay Press buttons Any number of button 3114 11 other than in 311 1 Button set in 311 8114 1 Regime m 6 Action Note Parameter Relay Press of the button Any number of button 3116 _ other than in 311 Button set in 311 or 312 3116 7 Note t1 time of connection of relay 1 parameter 371 t2 time between impulses of relay 1 parameter 301 Tab 1 Table of relay controls 3 4 Person in the building The person in the building means the person who is in telephone contact with the Brave entry system i e Mr Smith 3 4 1 Outbound call An outbound call is a call from the Brave system i e started by a visitor Once the system has been dialled a pho
35. ntify the exact moment this occurs Function for relay connections by inputting a combination of up to 4 buttons or keyboard keys after pressing the key symbol between Doorphone Brave and the electric lock can be connected code relay COSW CodeSwitch which is located at the lock and lock activates only when is the same the specified serial combination of the Brave and set the code on the board relay COSW Combination of 1 2 or 4 buttons or 10 keyboard keys after pressing the key symbol for a relay connection External being input on the Brave outside the building Digits combination dial from phone for relay activation DTMF Internal dial by phone inside building phone connected to other PBX extension The manufacturer continuously improves the product firmware The technology used allows you to upload to Brave the latest version of the firmware any time using a standard computer with BraveSet and USB cable The latest version of the firmware is available at http www alphatech cz BRAVE SlimDP User and service manual 7 1 3 Brave SlimDP versions and differences The Brave door entry system is conceived as system that provides a final solution based on a modular design The features and parameters that are available to and can be set differ for each version of the Brave It is therefore necessary to set the parameters for all versions including any add on parameters for each version Available Features
36. ones the Brave SlimDP plays during installation as it will assist in the analysis of its state and operation The sounds can be turned off in several levels parameters 61 62 63 and 65 To play and listen to the sound signals go to www alphatech cz zvukova signalizace 3 html BRAVE SlimDP User and service manual 3 2 Caller at the door The door entry system s buttons are labelled in the same way as normal doorbell buttons Visitor finds the appropriate name for example Mr Smith and presses the button The Brave will pick up a line plays the pick up line tone if it is not prohibited para 62 and dials the phone number saved under that button parameter 1 or 2 depending on system regime From the Brave s speaker a ringing tone will be heard and Mr Smith s phone will ring As soon as Mr Smith picks up he can talk to his visitor If an electric lock is also connected to the Brave Mr Smith can press a DTMF code on his phone and let visitor in If he puts down the phone the Brave will disconnect If the call lasts longer than the pre set limit parameter 52 10sec before disconnection the Brave will send a line disconnection tome but Mr Smith can dial or parameter 42 to prolonged the call for the length of time set in parameter 52 The dialled number depends on the regime mode which is set in the system parameter 47 Regime Day Night if the system is in Day mode it dials the number set in parameter 1 if the system i
37. prolonging t Command for Brave disconnection from 43 gbb the phone 00 99 0 9 195 266 44 BRAVE SlimDP User and service manual 44 XXXX Service password 0000 9999 0000 Command for switch over to DAY 45 dd 00 99 0 9 11 Command for switch over to NIGHT 46 nn 0099 0 9 10 47 Regime system choice 0 1 1 4 k Line disconnection by repeat press of the 1 same button 0 1 Umber of rings before Brave picks up 1 9 Maximum length of call 0 9 Time between button presses 1 9 Time of disconnection for repeat choice 1 5 Time before choice begins 1 5 Number of rings before disconnection 04 99 Medium frequency of tone detector 375 475Hz Number of busy tones 2 0 4 Length of time for permanent tone 1 5 3 3s Length of time for DTMF tone choice 04 16 10 100ms Length of time for gap between DTMF tones 04 16 10 100ms Length of time Flash 1 6 1 100ms Length of time for pause inter digit gap 1 0 4 800ms Level of transmission of DTMF choice v dBm 04 16 10 preemphase DTMF 0 1 61 Listening in DTMF level 1 4 Acoustic signalisation confirmation error empty memory end of call 0 1 62 Acoustic signalisation Intro Concl 0 1 63 Acoustic signalisation ticking into a call 0 1 65 Acoustic signalisation for relay switch
38. relay r in order p 1 5 for 1 impulse and p for 2 impulses In regime Night password hh for relay r in order p 1 5 for 1 impulse and p for 2 impulses 11 444444 relay number relay number 1 in SlimDP p order 1 5 for 1 impulse 5 passwords external codes from Brave s buttons external code of code lock p Order to set password external code for 2 impulses hh password external code for relay switching on from button or keyboard 2 to 6 places Buttons 1 4 are programmed as numbers 1 4 All together 3x12 passwords depending on the Day Night setting combinations are be input either with the help of the buttons only butons on panel max 4 Switching on a relay is affected by the relay regime and the choice Day Night if the regime 2 groups of numbers is set the system is constantly in regime DAY There are several rules that needs to be followed when setting a password Choose the first button of password from buttons that are the least used for direct dialling prolonging time mindful about conformity of numbers i e when 1 password contains another Note When setting parameter 32 33 34 signs and and 5 6 7 8 9 0 are not used because they are not on the button panel TEE command aa from phone for pene relay number relay number 1 in SlimDP 2 in oa aa command internal code for switching on the relay from the phone 2
39. rt of delivery and must be ordered separately Further details of power supplies and electric locks can be found at www alphatech cz 2 7 4 USB Programming cable The USB cable is the same as that used for the SlimDP door entry system The USB drivers can be found on the web site www alphatech cz BRAVE SlimDP User and service manual 3 Door Entry System Operation The Brave SlimDP door entry system s functions are set by establishing parameters see the chapter on parameter programming page 23 3 1 Signalling overview Brave SlimDP acoustic signals that occur during its operation Samples of sounds can be listened to in the setting programme BraveSet State Tones Tone frequency Pick up line type 1 eg 980 1333 1650 Disconnection of line type 1 ae 1650 1333 980 Pick up line type 2 m 800 1067 1200 1333 Disconnection of line type 2 Hau 1333 1200 1067 800 Confirmation of command from the phone J 800 Ticking during a call LL Notice about the end ofa call 1333 Relay switch signal Modulated Entry into programming from the phone ggal 980 1067 1180 Programming from the phone Modulated Parameter confirmation 800 Entry into programming from the PC ggal 980 1067 1180 Line connection Reset 1850 1067 1850 Error generally something is not right dba 800 Empty memory no number is programmed se g 1300 2100 It is useful to know what t
40. rther it is possible keyboard use to dialling numbers Exit button can control one or the other relay and relay in keyboard it is possible control from phone during conversation too parameter 30 Code lock for relay in Doorphone from buttons stays conserved Connection by special cable is make that way will you use programming connectors 8pin To programming from PC is usings same USB cable USB KABslim and program ID Manager is in new version 2010 equipped also by program for setting keyboard To basic function is necessary have connected to Doorphone telephone line and to keyboard 12V 12V for heating board and power supply of relay in Doorphone can use from same source and it is possible use also for power supply of locks Recommended is use low power locks The choice is entered by gradual pressing of buttons with digits Firstly the key symbol must be pressed to enter a password When pressing X the guard will hang up 16 BRAVE SlimDP User and service manual 2 6 Code relay COSW For the switch relay is available function code relay COSW CodeSwitch It serves primarily to secure transmission of information by switching the electric lock When using this function is not possible connecting or disconnecting the voltage at the terminals to lock this lock activated Activation is performed only when positive result compared serial information transmitted between Brave and the board code relay pec Brave
41. s in Night mode it dials a number set in parameter 2 The switching over of regimes manually is set in parameters 45 46 Regime 2 groups of numbers the first press of the button always dials a number set in parameter 1 Following the repeated pressing of the same button when it detects a busy tone 10sec after choice or after a pre set number of rings parameter 56 the system dials a number from the second group parameter 2 After another press of the same button the system will again dial the number from the first group or after detecting a busy tone on the dialling of a number from the group 2 the repetition ends If a visitor presses the button after the system has picked up the system will disconnect for a length of time as set in parameter 54 before it picks up the line and dials a new number The number choice takes place either by tone DTMF or impulse according to the setting in parameter 41 There is one more option disconnection of line after repeat pressing of the same button parameter 4 It is possible to control a relay switch code lock with the first 4 buttons If visitor at the door presses buttons in the correct combination according to a pre programmed code parameter 32 34 and the length of time between presses isn t greater than the pre set time parameter 53 the system picks up switches the appropriate relay if it is set in mode m 1 for the length of time given in parameter 37 or 39 30 and then disco
42. spaces To set the same commands for both relays internal code so that both relays activate at the same time It is also recommended that the same command is set for relay on and command to disconnection of system parameter 43 aa bb 1 command is always 2 digits but if you wish to control relay with a single digit from the phone there is an option to input a where a is a single number and the star represents an empty space and must be in the first place BRAVE SlimDP User and service manual 27 Example 1 relay switch on internal code 48 is programmed 35148 J 2 relay switch on internal code 8 is programmed 352 8 By choosing no 8 on the phone we switch on just the second relay with option 48 we switch on both relays Note second relay is in SlimKey module works only if is SlimKey connected meaning Bac command aa from phone for switching relay number relay number 1 in SlimDP cc command internal code for switching on the relay from the phone 2 spaces To set the same command for both relays internal code so that both relays activate at the same time 1 command is always 2 digits but if you wish to control relay with a single digit from the phone there is an option to input a where a is a single number and the star represents an empty space and must be in the first place Switching a relay on with 2 impulses is used for sliding gates replacing a gate entry Example Co
43. ter Value Meaning Basic Suppression of the reception DTMF from the microphone 0 1 Suppression of the reception from the microphone is off as a default It is possible to open the door with a personal dialler without disturbing a person inside the building For higher security it is possible to switch on the suppression function iz1 and stop a person with an unauthorised copy of the DTMF code from entering Parameter Value Meaning eose 67 Baby Call call without the need to programme a telephone number 0 1 This function is turned off as standard b 0 By switching on this function bz1 the acoustic signal for an empty memory is cancelled so after pressing a button with an empty memory there is only a beep confirmation and a call is activated as if there were a number Warning During the first 10 seconds of a call the tone detector is inactive there is a pause before the switchboard responds or number dialling by the switchboard 68 b Mute at the lock activated 0 1 Low Default is off m 0 By enabling the m 1 mutes the acoustic path at close relay 1 or 2 in electric lock modes 1 and 5 This feature is there because if you often use code lock function or exit button so the switch on time to hear the tone exchange For some customers this can be distracting 38 BRAVE SlimDP User and service manual Parameter Setting of the number of buttons on the main 2
44. ter 381 when an incoming call can disable the relay controls 3 4 3 Door Entry System with keyboard module SlimKey If a keyboard module is connected to the system then it is necessary to set the following parameters Parameters for control second relay is in parameters same for relay 1 inside Brave SlimDP but with index relay 2 For using features in SlimKey is need set in SlimKey parameter connection with SlimDP to Next is possible dial telephone numbers from keyboard and control relay 1 by code from SlimKey and from exit button connected on SlimKey This settings is on SlimKey in Brave SlimDP is connection with SlimKey detected automaticaly 22 BRAVE SlimDP User and service manual 4 Parameter programming 4 1 Programming with the help of a phone 4 1 1 Entry into the programming There are two ways to enter the Brave s programming system 1 With the help of a password incoming calls only pick up a phone and dial the number that the Brave is connected to either the number of the branch if you are connected to a switchboard line or the number of the line to the building where the Brave is and ask be connected to the branch to which the Brave is connected The brave will pick up you will hear the pick up tone see chapter 3 1 page 19 within 10 secs press xxxx where xxxx is the service password to enter the programme system in the basic setting xxxx 0000 if correct there will
45. tones nn x 10 504 2 Length of time Flash nx 100 505 1 Length of time of pause nx100 400 506 1 a DESEAN level DTMF 04 16 507 dB preemphase DTMF 0 1 508 Listening in DTMF level 1 4 509 Acoustic signalisation other 0 1 Acoustic signalisation 0 1 Intro Concl Acoustic sign ticking 0 1 Signal tone turning on relay 0 1 Suppression of reception from 0 1 0 1 Mute at the lock activated 0 1 dependant Delayed start Siemens 0 1 no of buttons on the panel Reception volume TRH Transmitting volume MIC Speaker volume SPK Soft transition of switch over Suppression of background noise microphone switch on threshold Speed of switching over voice atomization VA characteristic Compensation for loss of conduit Level of signalisation trans 50 BRAVE SlimDP User and service manual WARRANTY Each and every product has been tested before it leaves the factory The manufacturer guarantees that the product and its features will work in accordance with the descriptions in this manual as long as the customer uses the product in accordance with the manufacturer s instructions Warranties will be extended when a warranty repair has been undertaken Although all warranty repairs will be handled by the manufacturer it is important that warranty claims are handled through your dealer Warranty claims should be accompanied by
46. ugh the cable hole Fix the panel to the wall using the screws and rawlplugs supplied Drill draw is on page 52 Note Some materials such as metal and wood may require special screw types To power the unit for voice connect the telephone wires into the terminal on the right side Using either a standard analogue phone line or an analogue extension on a PBX For the external power supply connect to the terminal 12V external power supply AC min 10V max 18V or DC min 12V max 24V The energy consumption of a connected electrical magnetic lock 0 5A 1 0A determines the load on the power supply If you activate the heating feature the PCB current will climb to about 150mA We recommend power supply AC 12V 1A for normal version and we recommend power supply DC 12V 1A for version with amplifier 10 BRAVE SlimDP User and service manual The wiring of relay contacts is explained in the next picture The symbol NO means contact normally open COM means sharing output central and NC means contact normally closed The relay contact is isolated from the other circuits on the board For the variants of lock connection see the picture below Telephone line LINE Wiring of standard and magnetic inverse lock 7 A special USB cable enables the doorphone to be connected to a PC for programming of individual parameters A dedicated Windows program is included on the CD requires version W98SE or
47. ve reverts to a default state where it is possible to either repeat the parameter programming or start programming a different parameter The Brave will automatically disconnect form the programming regime after a period of inaction 30 sec With each DTMF tone dialled the time will always resets to 30 sec It is also possible to end the programming regime by choosing parameter 9 BRAVE SlimDP User and service manual 23 Note If you want to keep a connection opened during the programming prolong the 30 sec time regime i e before a customer decides what else he wants to be set then you can press or the Brave immediately answers with an error tone but will prolong the time before disconnecting 4 2 Programming with the help of a PC programme BraveSet To programme the Brave with the PC you will need to use the special cable USB KABslim and programme BraveSet The Brave will also need to be connected to a telephone line Procedure Connect the Brave SlimDP to the line Connect Brave SlimDP to the PC via the USB cable The Brave will pick up a line and within 3 seconds a tone for programming entry will be heard see chapter 3 1 Page 19 Run programme BraveSet Until the USB is disconnected the Brave is connected to the PC and is in programming regime and will not run any other operations lf you lose connection you will need to reconnect the USB cable the Brave will then pick up Connection between the Brave an