Home
        Badu® EcoM3 - INYOPools.com
         Contents
1.     5  Hand tighten the lid to make an air tight seal  Do not use any tools to tighten the lid  hand tighten  only  Make sure all valves are open and the unions are tight     6  Once all the air has left the filter  close the pressure release valve     7  Switch on power to the pump motor to start  There will be a delay of six to twelve  6 to 12  seconds as  the EcoM3 powers up     8  The unit will automatically run on high speed for two  2  minutes to prime the pump  After the two  minutes the pump will default to low speed  Note  If you press the medium or high button during the two   2  minute priming  the pump will then run for two  2  hours on the speed you selected then default back  to low     9  The pump has three  3  speed settings   low  medium  and high     High Speed  Used when vacuuming the pool or operating the spa jets or some water features  such as water falls     Medium Speed  Used for gentle spa jet action  or filtration for the pool     Low Speed  Recommended for everyday filtration of your pool   This speed will achieve the  lowest operating costs with the lowest noise level      10  If the power is turned off to the pump  it will repeat this process   See number 6     11  Ifthe pump does not prime and all the instructions to this point have been followed  check for a suction  leak  If there is a leak repeat Steps 2 through 6     12  For technical assistance  call Soeck Pumps Technical Support at 800 223 8538     5 Service and Maintenance    Routine Maint
2.  BONDING AND GROUNDING   1  The motor frame must be grounded to a reliable grounding point using a solid copper conductor   No  8 AWG or larger  In Canada  No  6 AWG or larger must be used  If the pump is installed within five   5  feet of the inside walls of the swimming pool  spa  or hot tub  the motor frame must be bonded to  all metal parts of the swimming pool  spa  or hot tub structure and to all electrical equipment  metal  conduit  and metal piping within five  5  feet of the inside walls of the swimming pool  spa  or hot tub     2  Bond the motor using the provided external lug     WARNING  Always disconnect the power source before working on a motor or its connected  load     WARNING  In order to avoid the risk of property damage  severe personal injury  and or death   make sure that the control switch  time clock  or control system is installed in an accessible  location  so that in the event of an equipment failure or loose plumbing fitting  the equipment  can be easily turned off     CAUTION  The pump must be permanently connected to a dedicated electrical circuit  No  other equipment  lights  appliances  or outlets may be connected to the pump circuit  with the  exception of devices that may be required to operate simultaneously with the pump  such as a  chlorinating device or heater     WARNING  Motor fitted with internal auto reset  May restart without warning     Electrical Wiring    1  The pump motor must be securely grounded using the  10 green headed groun
3.  height between  the pump and water level should not be more than five  5  feet     If the pump is located below water level  isolation valves must be installed on both sides of the pump to  prevent the back flow of pool water during any routine or required servicing  The Badu EcoM3 comes  equipped with unions on both the suction and discharge ports  This feature simplifies installation and  service and eliminates the possibility of leaks at the threaded adaptors     Before starting the pump for the first time  remove the see through lid   Turn lid counter clockwise to  remove   Fill strainer tank with water until it is level with the suction inlet  Replace lid  making sure the  o ring is not damaged  Screw down  hand tight     Suction and discharge line should be independently supported at a point near the pump to avoid strains  being placed on the pump  Always use properly sized valves     Use the fewest fittings as possible  Each additional fitting has the effect of moving the equipment farther  away from the water     NOTE  If more than ten  10  suction fittings are needed  the pipe size must be increased     Every new installation must be pressure tested according to local codes  See the Pressure Testing  Section on page 7    Electrical Installation    10    Electrical Installation    When installing and using the motor  basic safety precautions should always be followed  The wiring of  the motor should be done by a licensed electrician in accordance with local codes    
4.  workmanship for a period of twenty four  24  months  from the date that the pump is originally installed     2  Not withstanding any provisions herein to the contrary  the warranties  and obligations hereunder shall not in any event extend for more than  three  3  years beyond the date of shipment of the pump and motor  from the factory in Jacksonville  Florida     3  Warranty is void in the following cases  damages which result  in whole or in part from   a  careless or improper installation of the  pump or the motor   b  improper or negligent use and maintenance of  the pump or the motor   c  tampering with the pump or the motor by  unauthorized repair personnel     4  The manufacturer   s sole obligation hereunder shall be to replace  or repair any defective pump or motor  The manufacturer reserves  the absolute right to determine whether any defective pump or motor  should be replaced or repaired     5  Any customer who wishes to make a claim under this Limited  Warranty shall notify the manufacturer  of such claim by telephone or  by mail  After the customer has been authorized to return a defective  pump or motor  the customer must return the pump or motor to the  manufacturer at 8125 Bayberry Road  Jacksonville  Florida 32256   Any goods returned to manufacturer without prior authorization will be  returned to the shipper unopened        The manufacturer shall not bear any costs or risks incurred in shipping  a defective pump or motor to the manufacturer or in shippin
5. 57700  2921150700    160 1  160 2  412 1  143  101  582  894 1  595  914 1  412 5  174 2  230  433  412 2  161 2  113  914 2  554 2  721  721 1  721  amp  721 1  25  507       D  pe    lt     A E TR A OY eat a a a a et    wk ek Ce gk Se    es        fr 160    EL 160 1                                                 DESCRIPTION   LID   LOCK RING   LID   O RING   LID 137 x 5mm   BASKET   ONE PIECE   CASING   CAP   DRAIN  3 8     WITH GASKET   CASING  LEGO SPACER   GASKET    1 4  x 7 16    x 1       SCREW   CASING HEX SLOT M7 x 48mm SS  O RING   DIFFUSER 90 x 5mm   DIFFUSER   IMPELLER  ll  1 0HP S F 1 0 101 9 0mm M10  MECHANICAL SEAL  14mm    O RING   CASING 190 x 6mm   SEAL HOUSING 14mm   FLANGE   BOLT   FLANGE M8 x 25mm   WASHER   FLANGE BOLT  M8    SET   DISCHARGE UNION COMPLETE   SET   SUCTION UNION COMPLETE  COMPLETE UNION SET   SUCTION DISCHARGE  SPANNER   LID  OPTIONAL    SLINGER   SPLASH RING          60    50          40    30       3450 RPM    TOTAL HEAD IN FEET    20       10       2600 RPM       600 RPM             0 20 40 60 80 100 120  GALLONS PER MINUTE    A B C  and D represent California Title 20 System Curves       A   117 PVC Pipe  SCH40  C   2    PVC Pipe  SCH40   B   114    Copper Pipe D   212    PVC Pipe  SCH40     8 Limited Warranty    The manufacturer supplies a limited warranty to the original consumer  purchaser of the pump and motor on the following terms and condi   tions     1  The pump and motor are warranted to be free from defects in  material and
6. Installation  Operating   and Service Manual    Badu EcoM3    Swimming Pool Pump       A    POOL PRODUCTS  INCORPORATED    Technical Support  Address     Hours   Toll Free   Phone     Fax     Web site     Speck Pumps   8125 Bayberry Road  Jacksonville  FL  32256  USA    8 00 am to 5 00 pm EST  800 223 8538  904 739 2626  904 737 5261    www usa speck pumps com    O 2010 All Rights Reserved  Speck Pumps  Jacksonville Florida USA    This document is subject to change without notice     Date of Installation   Installed By     Serial Number     For Service Call  o    2999999978   Rev 03 2010    SAVE THESE INSTRUCTIONS     Table of Contents                            Important Safety Instructions 1  General Description 7  Installation Information 8  Preparation Guide   8  Pump Location 8  Pipe Sizing   9  Plumbing Installation   9  Electrical Installation   9  Bonding and Grounding     10  Electrical Wiring     10  Setting Up Remote Control 11  Voltage Checks   11  Pressure Testing  11  Operation 12  Service and Maintenance 13  Routine Maintenance     13  Winterizing     14  Troubleshooting 14  Controller Warnings poa   14  General Troubleshooting Problems   15  Product Specifications 16  Replacement Parts and Exploded View     16  Performance Curves   17  Limited Warranty 17    1 Important Safety Instructions    READ THIS MANUAL CAREFULLY BEFORE USING THE SPECK PUMP    READ AND FOLLOW ALL INSTRUCTIONS     Important Notice   This manual contains important information about the ins
7. age and void the warranty     There are two options when winterizing the pump    Option 1   1  Drain all the water from the pump  system equipment  and piping     2  Remove drain plugs  Do not replace plugs  Store the plugs in the empty strainer basket for winter   3  Keep the motor covered and dry     Option 2   1  Drain all the water from the pump  system equipment  and piping     2  Remove the pump and motor from the plumbing and store indoors in a warm and dry location     Note  When the winter season is over the pump will need to be primed prior to start  Refer to  Section 4 Operation  Start Up Guide     CAUTION  DO NOT run the pump dry  If the pump is run dry  the mechanical seal will be damaged  and the pump will start to leak  If this occurs  the mechanical seal will need to be replaced  ALWAYS  maintain the proper water level in your pool  Continued operation in this manner could cause a  loss of pressure  resulting in damage to the pump casing  impeller  and mechanical seal     6 Troubleshooting    WARNING  The pump must serviced by a professional service technician qualified in pool spa  installation  The following procedures must be followed exactly  Improper installation and or  operation can create dangerous electrical hazards  which can cause high voltage to run through  the electrical system  This can cause property damage  serious personal injury  and or death   Improper installation and or operation will void the warranty     The Badu EcoM3 warnings are indi
8. cated by a flashing LED light on the control panel  If the error light is  on pay attention to the appropriate number of flash intervals of short or long duration  then shut the pump  down immediately  For example  if a    Low Voltage    warning occurs  the LED will blink two times  then off   then blink two times  This sequence is repeated until the condition is cleared        Table 2 0    The Badu EcoM3 Warning Sequence       Flash Rate LED    Error    Light    Error Description    Cause                               1 Flash Microprocessor failure Microprocessor Start Up   2 Flashes Low voltage Voltage must exceed  lt  208V AC control  activates itself independently when voltage  exceeds 208V for more than six  6  seconds   Motor Activates    3 Flashes Temperature to high Temperature Too High  gt  100   C  212   F    Temperature to low Temperature Too Low  lt   20   C  4   F    4 Flashes Thermal overload tripped Motor is drawing to much current amps   5 Flashes High voltage Voltage has risen  gt  269V AC   6 Flashes Shaft locked Impeller or pump locked motor shaft stopped  turning   7 Flashes Self test One or more self test were not completed   8 Flashes Motor Error One or more phases is disconnected          General Pump Troubleshooting Problems    Table 2 0    The Badu EcoM3 General Problems       Problem    Possible Cause    Solution       1  Error Light appears during start up    A  Low Voltage    During the initial start up  6 12 sec   onds delay  or momentary power dr
9. ce and maintenance     4  Protect the pump against flooding and excess moisture  and event foreign objects from clogging  air circulation around motor  All motors generate heat that must be removed by providing proper  ventilation     5  DO NOT store or use gasoline or other flammable vapors or liquids in the vicinity of this pump  DO  NOT store pool chemicals near the pump     6  DO NOT remove any safety alert labels such as DANGER  WARNING  or CAUTION  Keep safety  labels in good condition and replace any missing or damaged labels     7  Provide access for future services by leaving a clear area around the pump  Allow plenty of space  above the pump to remove lid and basket for cleaning     Pipe Sizing    NOTE  All pipe sizes are able to withstand the pressures the pump will deliver  but not  necessarily the flow  If the pipe is too small for the pump  or is elevated above water  the  maximum gallons per minute  GPM  may not be delivered  If this happens  the pump will  develop a pocket of air  cavitation  that makes noise  This may shorten the life of the pump     SUCTION  amp  DISCHARGE   When the pump is located up to 50 feet from the pool  the recommended minimum pipe size for both  the suction and discharge is 2    for 0 75 HP to 1 5 HP  full rated pumps      Plumbing Installation    When installing the pump  care should be taken to see the suction line is below water level to a point  immediately beneath the pump to ensure quick priming via a flooded suction line  The
10. d  Drain covers must be listed certified to the latest published  Hazardous suction  edition of ANSI ASME A112 19 8  They must be replaced if cracked   Can trap hair or body broken  or missing     parts  causing severe  injury or death     Do net block suction  Number of Suction Outlets Per Pump  Provide at least two  2     hydraulically balanced main drains  with covers  as suction for each       circulating pump suction line  The centers of the main drains  suction outlets  on any one  1  suction line  must be at least three  3  feet apart  center to center     The system must be built to include at least two  2  suction outlets  drains  connected to the pump  whenever the pump is running  However  if two  2  main drains run into a single suction line  the single  suction line may be equipped with a valve that will shut off both main drains from the pump  The system  shall be constructed such that it shall not allow for separate or independent shutoff or isolation of each  drain     More than one  1  pump can be connected to a single suction line as long as the requirements above are  met     Water Velocity  7he maximum water velocity through the suction fitting or cover for any suction outlet  must be 1 5 feet per second  unless the outlet complies with the latest published edition of ANSI ASME  A112 19 8  the standard for Suction Fittings For Use in Swimming and Wading Pools  Spas  Hot Tubs   and Whirlpool Bathtub Applications  In any case  do not exceed the suction if fi
11. d screw provided  inside the motor terminal box     NOTE  Do not connect to electric power supply until unit is permanently grounded     2  Wire size must be adequate to minimize voltage drop during the start up and operation of the pump   See Table 1 for recommended wiring sizes     3  Insulate all connections carefully to prevent grounding or short circuits  Sharp edges on terminals  require extra protection  To prevent the wire nuts from loosening  tape them using suitable  listed  UL   ETL  CSA  electrical insulating tape  For safety  and to prevent entry of contaminants  reinstall all  conduit and terminal box covers  Do not force connections into the conduit box     Table 1 0  Recommended Wire Sizes for the Badu EcoM3                Recommended Wire Sizes For The Badu EcoM3  Distance from Sub panel 0   50 Feet 50   100 Feet 100   150 Feet  Voltage 208   230 VAC 208   230 VAC 208   230 VAC  Minimum Wire Size 12 10 8                      Setting up the remote control    The Badu EcoM3 consists of an operator control panel and the system electronics that drive the motor  along with a ten  10  foot remote controller cord  Speeds can be changed by the controller at the top of  the motor or remotely by use of a remote controller  External controller not provided  available through  Speck Pumps   This pump can also be plugged into an external controller  such as a time clock  to meet  all existing state or local codes  Figure 2  A3 Channel time clock with potential free contac
12. edium head pump uses a state  of the art axial flux permanent magnet brushless DC motor controlled by advance logic electronics   Providing cooler and quieter operation at a fraction of the cost of a standard PSC motor  The affinity  laws of hydraulics states that if you halve the speed  the power reduces by 8 times  The multiple speeds  offered by the Badu EcoM3 enables it to run slower and consume less energy but still have the ability to  run at full speed if required     The Badu EcoM3 operates at a maximum system flow of 100 gallons per minute  GPM      This pump can operate from 1600 RPM to 3450 RPM with preset speeds of 1600  2600  and 3450 RPM   This allows you to select the most appropriate speed for your application  The Badu EcoM3 was designed  to meet the needs of today s more environmentally friendly consumer  The pump parts are made of 100   recyclable    environment friendly    plastic  The axial flux brushless DC motor  has a significant reduction  in greenhouse gas emissions  Saving greater than 2 tonne CO  per year  Lower noise reduction  and  energy savings per year     The Badu EcoM3 control panel provides manual speed con   trols for the pump  There are three preset speed buttons that  can be selected low  medium  and high     Controls and LEDs  1  low  med  and high button LED  Press one of the buttons  to select the desired preset pump speed  The pump preset  speeds are  low  1600 RPM   med  2600 RPM   and high   3450 RPM   The button green LED is on wh
13. en the selected  button is pressed   2  Power LED  This green LED light is on when the Badu  EcoM3 pump is powered up    E 3  Error LED  This red LED is on whenever an error has oc    Power   Error curred     A       Figure 1    3 Installation Information    Preparation Guide    1  Upon receipt of the pump  check the carton for damage  Open the carton and check the pump for  concealed damage  such as cracks  dents  or a bent base  If damage is found  contact the shipper or  distributor where the pump was purchased     2  Inspect the contents of the carton and verify that all parts are included  See Section 7  Parts List and  Exploded View     Pump Location    NOTE  In Canada  the pump must be located a minimum of three  3  meters  approximately ten   10  feet  from the water  CSA C22 1      1  Speck Pumps recommends to achieve better self priming  install the pump as close to the pool as  practical  Consult local codes for minimum distance between pool and pump     WARNING  Some Safety Vacuum Release System  SVRS  devices are not compatible with  the installation of check valves  If the pool has an SVRS device  be sure to confirm that it will  continue to safely operate when the check valves are installed     2  The piping should be as direct and free from turns or bends as possible  as elbows and others fittings  greatly increase friction losses     3  Place pump on solid foundation which provides a rigid and vibration free support so that it is readily  accessible for servi
14. enance    This pump requires little or no service other than reasonable care and periodic cleaning of the strainer  basket     1  Inspect the pump basket for debris by looking through the clear pump lid     2  Turn off the power to the pump  If the pump is located below the water level  close isolation valves on  the suction and discharge sides of the pump to prevent back flow of water     3  Remove any debris  because as the debris accumulates  it will begin to block the flow of water  through the pump  Keep the basket clean and clear to improve the performance of the pump     4  Turn the lid   s lock ring counter clockwise until it stops  Carefully remove the lid and lock ring     5  Remove the basket and properly dispose of the debris into the trash and rinse out the basket  Check  basket for cracks  if crack is found replace basket     6  Replace basket back into the pump  align the basket properly with the suction pipe  Then fill with  water up to the suction pipe  Clean clear cover  lid o ring and sealing surface of the pump of any debris     14    Routine Maintenance   continued    6  Replace lid with locking ring  Hand tighten the lid to make an air tight seal  Do not use any tools to  tighten the lid     7  Verify that all valves have been returned to the proper position for normal operation  Turn on the  power to the pump     Winterizing    CAUTION  The pump must be protected when freezing temperatures are expected  Allowing the  pump to freeze will cause severe dam
15. g a repaired  or replaced pump or motor to a customer     6  The manufacturer will charge customers for all non warranty work  which it may perform  Non warranty work will not be performed until  the customer has accepted the price quoted     7  EXCEPT AS SPECIFICALLY SET FORTH ABOVE  NO  OTHER WARRANTIES  WHETHER EXPRESS OR IMPLIED   INCLUDING WITHOUT LIMITATION  THE IMPLIED WARRANTIES  OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR  PURPOSE  ARE MADE BY THE MANUFACTURER  IN NO  EVENT WILL THE MANUFACTURER BE LIABLE FOR ANY LOSS   INCLUDING TIME  MONEY  GOODWILL  LOST PROFITS AND  CONSEQUENTIAL DAMAGES BASED ON CONTRAST  TORT OR  OTHER LEGAL THEORY  WHICH MAY ARISE HEREUNDER OR  FROM THE USE  OPERATION OF MODIFICATION OF THE PUMP   MOTOR OR ASSOCIATED PARTS  THE MAXIMUM LIABILITY OF  THE MANUFACTURER HEREUNDER SHALL NOT EXCEED THE  AMOUNT ACTUALLY PAID BY THE CUSTOMER FOR THE PUMP   MOTOR AND ASSOCIATED PARTS     8  Some states do not permit limitations on the terms of implied  warranties or on the recovery of incidental or consequential damages   Accordingly  the limitations contained in paragraph 7  may not apply  to certain customers     9  This warranty gives customers specific legal rights  Customers may  have other rights which vary from state to state     17       2999999978   Rev 03 2010 v1    
16. ide a properly located outlet      For swimming pool pumps with or without a maximum 3 foot  0 91 m  cora    CAUTION  This pump is for use with permanently installed pools and may also be used with hot tubs  and spas if so marked  Do not use with storable pools  A permanently installed pool is constructed in or  on the ground or in a building such that it cannot be readily disassembled for storage  A storable pool is  constructed so that it may be readily disassembled for storage and reassembled to its original integrity     TO REDUCE THE RISK OF ELECTRICAL SHOCK  connect ground wires to grounding screw located in  the motor  Use no smaller than a  12 AWG  3 3mm2  wire     TO REDUCE THE RISK OF ELECTRICAL SHOCK  a bonding connector is provided for bonding to  metal water pipes  metal rails  or other metal within 5 feet of the swimming pool  All local points should be  bonded with a  8 AWG  8 4mm2  wire      For hot tub and spa pumps     CAUTION  Do not install within an outer enclosure or beneath the skirt of a hot tub or spa unless so  marked     SAVE THESE INSTRUCTIONS     2 General Description    Badu EcoM3    The Badu EcoM3 swimming pool pump is both environment friendly and cost efficient  This revolutionary  three speed pump provides the pool owner a simple three button control to operate the pump  greatly  reducing the operating cost at a reasonable investment  The robust pump is based on Speck Pumps  energy efficient design platform  The Badu EcoM3 high performance  m
17. op   in which case the pump will restart  itself after the voltage is above 208V  for a period of six seconds        2  Pump will not prime     A  Suction air leak    B  No water in pump     C  Closed valves or blocked lines     D  Low voltage to motor     Make sure see through lid and o rings  are clean and properly positioned   Hand tighten see through lid  Tighten  all pipes and fittings on suction side  of pump  Be sure water in pool is high  enough to flow through skimmer     Make sure strainer tank is full of water   Open all valves in system  Clean skim   mer and strainer tank  Open pump and    check for clogging of impeller     Check voltage at motor  If low  pump  will not come up to speed        3  Motor does not turn    A  No power to motor     B  Pump jammed    Check that all power switches are   on  Be sure fuse or circuit breaker is  properly set  Time set properly  Check  motor wiring at terminal     With power off  turn shaft  It should  spin freely  If not  disassemble and  repair        4  Low flow       A  Dirty filter    B  Suction Leak    Back wash filter when filter pressure is  high  or clean cartridges   See Problem 2             15    16    Product Specifications       PART NUMBER DRAWING NUMBER    2921116010  2921116020  2901141201  2901114300  2921110108  2901158200  2920889410  2920889420  2991000088  2920141210  2921117412  2920723101  2920143310  2921141222  2921116125  2921111300  5879120825  2991000062  2500300902  2921770001  2500300914  29211
18. stem with water  air is often trapped in the system during  the filling process  This air will compress when the system is pressurized  Should the system  fail  this trapped air can propel debris at a high speed and cause injury  Every effort to remove  trapped air must be taken  including opening the bleed valve on the filter and loosening the  pump basket lid while filling the pump     WARNING  Trapped air in the system can cause the filter lid to be blown off  which can result in  death  serious injury  or property damage  Be sure all air is properly purged out of the system  before operating  DO NOT USE COMPRESSED AIR TO PRESSURE TEST OR CHECK FOR  LEAKS     11    12    Pressure Test   continued    WARNING  When pressure testing the system with water  it is very important to make sure that  the pump basket and lid is completely secure     STEPS   1  Fill the system with water  using care to eliminate trapped air     2  Pressurize the system with water to no more than 35 PSI     WARNING  Do not pressure test above 35 PSI  Pressure testing must be done by a trained pool  professional  Circulation equipment that is not tested properly might fail  which would result in  severe injury or property damage     3  Close the valve to trap pressurized water in the system   4  Observe the system for leaks and or pressure decay     5  If there are leaks  repeat Steps 1  3  For technical support  call 1 800 223 8538     4 Operation    CAUTION  Never run the pump without water  Running 
19. tallation  operation and safe use of this product   This information should be given to the owner and or operator of this equipment     WARNING  Before Installing this product  read and follow all warning notices and instructions which  are included  Failure to follow safety warnings and instructions can result in severe injury  death  or  property damage  Call 1 800 223 8538 or visit www usa speck pumps com for additional copies of these  instructions     WARNING   Entrapment Prevention    DANGER  DO NOT BLOCK SUCTION    SUCTION HAZARD  Can cause serious injury or death  Do not use  this pump for wading pools  shallow pools  or spas containing bottom  drains  unless pump is connected to at least two  2  functioning suction  outlets     44 DANGER    WARNING  Pump suction is hazardous and can trap and drown or  IL disembowel bathers  Do not use or operate swimming pools  spas  or  Hazardous suction  hot tubs if a suction outlet cover is missing  broken  or loose   Can trap hair or body  parts  causing severe  injury or death    Do not block suction     The following guidelines provide information for pump installation  that minimizes risk of injury to users of pools  spas  and hot    tubs   A DANG ER Entrapment Protection  The pump suction system must provide  protection against the hazards of suction entrapment       Suction Outlet Covers  A   suction outlets must have correctly installed     screw fastened covers in place  All suction outlet  drain  covers must be  maintaine
20. th or serious injury  to pool users  installers  or others due to electrical shock  and may also  cause damage to property     A WARNING    seal ees aig Always disconnect power to the pool pump at the circuit breaker  causa death  before servicing the pump  Failure to do so could result in death or  Disconnect power before serious injury to serviceman  pool users  or others due to electric shock     working on pump or motor        Important Safety Precautions    When installing and using this electrical equipment  basic safety precautions should always be  followed  including the following     READ AND FOLLOW ALL INSTRUCTIONS     For all units   WARNING  To reduce the risk of injury  do not permit children to use this product unless they are closely  supervised at all times      For cord and plug connected units    WARNING  Risk of Electrical Shock  Connect only to a grounding type receptacle protected by a ground   fault circuit interrupter  GFCI   Contact a qualified electrician if you cannot verify that the receptacle is  protected by a GFCI      For cord and plug connected units   WARNING  Do not bury the cord  Locate cord to minimize abuse from lawn mowers  hedge trimmers   and other equipment      For cord and plug connected units   WARNING  To reduce the risk of electrical shock  replace damaged cord immediately      For cord and plug connected units   WARNING  To reduce the risk of electrical shock  do not use extension cord to connect unit to electrical  supply  prov
21. the pump  dry  for any length of time can  cause severe damage to both the pump and the motor and will void the warranty     If this is a new pool installation  make sure all piping is clear of construction debris and has been properly  pressure tested  The filter should be checked for proper installation  verifying that all connections and  clamps are secure according to the manufacturer   s recommendations     WARNING  To avoid risk of property damage  severe personal injury or death  verify that all power  is turned off before starting this procedure     1  Release all pressure from the system and open the filter pressure release valve     2  Depending on the location of the pump  do one of the following      If the pump is located below the water level of the pool  open the filter pressure valve to prime the pump  with water      If the pump is located above the water level of the pool  remove the lid and fill the basket with water  before starting the pump  DO NOT run the pump without the basket     3  Make sure pump turns freely  especially after extended periods of down time  Note  To turn the shaft  place a screwdriver into the slot at the fan end and turn it by in the direction of rotation  If necessary  remove the fan cover and turn the fan by hand  After re starting make sure the mechanical seal does not  leak     4  Prior to replacing the lid  check for debris around the lid o rings seat  Debris around the lid o ring seat  will make it difficult to prime the pump 
22. ts   Also called     dry contacts     A device using    momentary switches    would also work  NOTE  If remote controller cable is  not used  the wiring needs to be isolated  The ends MUST NOT TOUCH or the speeds may be affected    To Connect to a Remote Controller   1  Remove power from the Badu EcoM3 by disconnecting the high voltage lines or by opening any  breaker to which the pump power is connected     WARNING  Electrical Shock Hazard   Turn off all switches and main breaker in  the Badu EcoM3 electrical circuit before  starting the procedure  Failure to comply p                Red   High   3450 RPM  may cause a shock hazard  resulting in    zs Blue   Medium   2600 RPM  severe personal injury or death     White  lt  Low  lt  1600 RPM       2  For technical assistance  call Speck  Pumps Technical Support at Black  lt  Common  800 223 8538              Figure 2    Voltage Checks    The correct voltage  as specified on the pump data plate  is necessary for proper performance and long  motor life  Incorrect voltage will cause the error light to turn on and cause damage to the motor if not  turned off immediately     It is the responsibility of the electrical installer to provide data plate operating voltage to the pump by  ensuring proper circuit sizes and wire sizes for this specific application     CAUTION  Failure to provide data plate voltage during operation will cause the motor to  overheat and void the warranty     Pressure Test    WARNING  When pressure testing a sy
23. tting   s maximum designed  flow rate     If 100  of the pump   s flow comes from the main drain system  the maximum water velocity in the pump  suction hydraulic system must be six  6  feet per second or less  even if one  1  main drain  suction  outlet  is completely blocked  The flow through the remaining main drain s  must comply with the latest  published edition of ANSI ASME A112 19 8  the standard for Suction Fittings For Use in Swimming and  Wading Pools  Spas  Hot Tubs  and Whirlpool Bathtub Applications     Testing and Certification  Suction outlet covers must have been tested by a nationally recognized  testing laboratory and found to comply with the latest published edition of ANSI ASME A112 19 8  the  standard for Suction Fittings For Use in Swimming and Wading Pools  Spas  Hot Tubs  and Whirlpool  Bathtub Applications     Fittings  Fittings restrict flow  for best efficiency use fewest possible fittings  but at least two  2  suction  outlets      Avoid fittings that could cause an air trap     Pool cleaner suction fittings must conform to applicable International Association of Plumbing and  Mechanical Officials  IAPMO  standards     WARNING   Risk of Electrical Shock or Electrocution    This pool pump must be installed by a licensed or certified electrician or  a qualified pool serviceman in accordance with the National Electrical  Code and all applicable local codes and ordinances  Improper installation  will create an electric hazard which could result in dea
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
FILTRI DEFERRIZZATORI AUTOMATICI SERIE: FDV/T  ST-213取説出稿 [更新済み]-1  和訳 - 国際エネルギースタープログラム  Amana AGR4230BAW Installation Instructions  AEG Eclipse 10  Sierra M6-2 SAS/SATA Protocol Analyzer User Manual  A Learning Model for 8051 Microcontroller Case Study on  115122-luzerne brins longs  フジトップカラーECⅢ 主剤  ETUDE COMPARATIVE DE PLUSIEURS PHYTASES SUR    Copyright © All rights reserved. 