1. Ib Performance Tests Use a network analyzer to perform the following return loss test on your adapters as soon as you receive them Periodically repeat the test to determine if the performance meets the electrical specifications stated on the previous page or if they need to be replaced An initial period of one year between performance tests is recommended NOTE If you are testing adapters that are not specified above 40 GHz serial numbers below 101 and no serial numbers replace the 50 GHz value in the previous table with the 40 GHz value Required Equipment Keysight Model or Part Number Network analyzer PNA with Option 010 See PNA 50 GHz or higher Family Microwave Network measurement capability with Analyzers Configuration Guide time domain option 010 part number 5990 7745EN 2 4 mm loads included in the 00901 60003 male 85056A calibration kit 00901 60004 female 2 4 mm 50 ohm airline 5 0 cm 85057 60001 included in the 85057B verification kit 85130G Operating and Service Manual 3 Figure 2 Return Loss Setup PORT 50 OHM TEST SET AIRLINE LOAD ADAPTER 85130_010_002 Return loss is measured by connecting a 50 ohm fixed load termination through a 5 0 cm airline to the adapter then attaching the adapter to port one of the test set see Figure 2 The effects of an imperfect load may be gated out using the network analyzer time domain option NOTE Refer to your netw
2. 27 7015 b 2 November 1995 as applicable in any technical data Safety Notices CAUTION A CAUTION notice denotes a haz ard It calls attention to an operat ing procedure practice or the like that if not correctly performed or adhered to could result in damage to the product or loss of important data Do not proceed beyond a CAUTION notice until the indicated conditions are fully understood and met A WARNING notice denotes a hazard It calls attention to an operating procedure practice or the like that if not correctly per formed or adhered to could result in personal injury or death Do not proceed beyond a WARNING notice until the indicated condi tions are fully understood and met 85130G Adapter Kit General Information To obtain optimum performance from this adapter kit observe these simple precautions e Make connections carefully to avoid misalignment and connector damage which will result in inaccurate measurements Keep the connectors free of dirt and any particles e When you clean the connectors try using compressed air first Do not use abrasives With a clean foam swab apply only isopropyl alcohol For more information refer to the Connector Care for RF and Microwave Coaxial Connectors document It can be viewed online by searching for part number 08510 90064 at www keysight com Description The 85130G contains two adapters designed to protect 2 4 mm connectors on a test
3. Keysight 85130G NMD 2 4 mm to 2 4 mm Adapter Kit This manual applies directly to Keysight 85130G adapters with serial number 101 and above An adapter with an earlier or no serial number is not specified above 40 GHz Operating and KEYSIGHT Service Manual TECHNOLOGIES NOTICE This document contains references to Agilent Technologies Agilent s former Test and Measurement business has become Keysight Technologies For more information goto www keysight com KEYSIGHT TECHNOLOGIES Notices Keysight Technologies 1991 2015 No part of this manual may be reproduced in any form or by any means including electronic storage and retrieval or transla tion into a foreign language without prior agreement and written consent from Key sight Technologies as governed by United States and international copyright laws Manual Part Number 85130 90043 Edition January 2015 Supersedes August 2013 October 2013 Keysight Technologies 1400 Fountaingrove Parkway Santa Rosa CA 95403 Warranty The material contained in this docu ment is provided as is and is subject to being changed without notice in future editions Further to the maxi mum extent permitted by applicable law Keysight disclaims all warranties either express or implied with regard to this manual and any information contained herein including but not lim ited to the implied warranties of mer chantability and fitness f
4. ipment and Supplies The following equipment and supplies are required for the maintenance and use of but are not supplied with your 85130G adapter kit Item Part Number 11752 60107 f 2 4 mm gage set part of 85056A calibration kit 11752 60108 m Torque wrench 20 mm 96 N cm 8 in Ib 8710 1764 Torque wrench 5 16 96 N cm 8 in Ib part of the 85052B calibration kits 8710 1765 Document Connector Care for RF and Microwave Coaxial Connectors 08510 90064 Contacting Keysight Assistance with test and measurement needs and information on finding a local Keysight office are available on the Web at www keysight com find assist NOTE In any correspondence or telephone conversation refer to the Keysight product by its model number and full serial number With this information the Keysight representative can determine whether your product is still within its warranty period 6 85130G Operating and Service Manual This information is subject to change without notice Keysight Technologies 1991 2015 January 2015 KEYSIGHT TECHNOLOGIES 85130 90043 www keysight com
5. ogies guarantees that your adapters will equal or exceed the following specifications Figure 1 85130G Specifications CENTER CONDUCTOR PROTRUSION No center conductor shoulder male pin end of female center pin protrusion is allowable on any connector CENTER CONDUCTOR RECESSION NMD 2 4mm PSC 2 4 NMD 2 4mm Female Female Male FP FP OUTER OUTER OUTER CONDUCTOR CONDUCTOR CONDUCTOR CENTER CENTER CENTER CONDUCTOR CONDUCTOR CONDUCTOR OUTER OUTER CONDUCTOR CONDUCTOR CONDUCTOR MATING PLANE MATING PLANE MATING PLANE MP male contact pin shoulder recession behind the outer conductor mating plane FP recession of the end of female center pin behind the outer conductor mating plane 85130G Operating and Service Manual Connector Allowable Recession mm in NMD 2 4 mm female 0 015 to 0 056 0 0006 to 0 0022 NMD 2 4 mm male 0 015 to 0 0254 0 0006 to 0 0010 PSC 2 4 mm female 0 015 to 0 0254 0 0006 to 0 0010 ELECTRICAL Adapter Frequency Range Return Loss DC to 26 5 GHz gt 28 dB 26 5 GHz to 40 GHz gt 23 dB NMD 2 4 mm f to NMD 2 4 mm m and NMD 2 4 mm f to PSC 2 4 mm f 40 GHz to 50 GHz 220 dB a Adapters with serial number gt 101 Proper Use Attach the adapters to the test ports and tighten them finger tight Use the spanner wrench to hold the test set end of the adapter and torque the test set connector with a 20 mm torque wrench set to 96 N cm 8 in
6. or a particular purpose Keysight shall not be liable for errors or for incidental or conse quential damages in connection with the furnishing use or performance of this document or of any information contained herein Should Keysight and the user have a separate written agreement with warranty terms cover ing the material in this document that conflict with these terms the warranty terms in the separate agreement shall control Technology Licenses The hardware and or software described in this document are furnished under a license and may be used or copied only in accordance with the terms of such license Restricted Rights Legend If software is for use in the performance of a U S Government prime contract or sub contract Software is delivered and licensed as Commercial computer soft ware as defined in DFAR 252 227 7014 June 1995 or as a commercial item as defined in FAR 2 101 a or as Restricted computer software as defined in FAR 52 227 19 June 1987 or any equivalent agency regulation or contract clause Use duplication or disclosure of Software is subject to Keysight Technologies standard commercial license terms and non DOD Departments and Agencies of the U S Gov ernment will receive no greater than Restricted Rights as defined in FAR 52 227 19 c 1 2 June 1987 U S Govern ment users will receive no greater than Limited Rights as defined in FAR 52 227 14 June 1987 or DFAR 252 2
7. ork analyzer s Help system for specific instructions on using the functions mentioned in the return loss test below Preset the analyzer Set a stimulus start frequency of the analyzer s lowest frequency Set a stimulus stop frequency of 50 GHz Set an IF bandwidth of 100 Hz Perform and then save a 2 4 mm 1 port S4 calibration With correction turned on select the time domain mode Set a stimulus start time for the sweep to 0 05 nano seconds Set a stimulus stop time for the sweep to 1 0 nano seconds o o NO oO FF WD Select the gating function and gate out everything but the adapter See Figure 3 10 Select the analyzer s frequency domain mode 11 Use the markers to read the return loss value 4 85130G Operating and Service Manual Figure 3 Analyzer Trace Showing Location of Gates and Airline Stop Gate S11 LINEAR REF i Adapter End of Airline Load End of Airline START 50 0 ps STOP 1 0 ns 85130_030_002 Performance Test Record ELECTRICAL SPECIFICATIONS Tested by Date Adapter Frequency Range Return Loss Measured NMD 2 4 mm f to DC to 26 5 GHz gt 28 dB NMD 2 4 mm m nd 26 5 GHz to 40 GHz gt 23 dB NMD 2 4 mm f to PSC 2 4 40 GHz to 50 GHz gt 20 dB mm f Replaceable Parts There are no replaceable components for the adapters A worn or damaged adapter must be replaced in whole 85130G Operating and Service Manual Equ
8. set for example If the application requires a male test port use the NMD 2 4 mm f to NMD 2 4 mm m adapter If the application requires a female test port use the NMD 2 4 mm f to PSC 2 4 mm f precision slotless connector adapter Precision Slotless Connectors When properly used a precision slotless connector should have the same lifespan as a standard slotted connector Keysight Technologies designed the precision slotless contacts to mate with all connectors within a connector series when those connectors meet published interface dimensions Mating a connector that does not meet published specifications can damage a precision slotless connector For this reason ensure that any device you connect is within its specifications Contents The 85130G kit contains the following e Test port adapter NMD 2 4 mm f to NMD 2 4 mm m Keysight part number 85130 60015 Test port adapter NMD 2 4 mm f to PSC 2 4 mm f Keysight part number 85130 60016 Storage box foam lined e Operating and Service Manual Spanner wrench 85130G Operating and Service Manual 1 Device Serial Numbers The adapters in this kit are individually serialized To help avoid confusing these adapters with similar adapters from other kits record the serial numbers in the following table Serialized Adapter Serial Number NMD 2 4 mm f to NMD 2 4 mm m NMD 2 4 mm f to PSC 2 4 mm f Specifications Keysight Technol