1. 14 1 The economic running function is available at cooling heating or auto mode Cooling The set temperature rise 1 C per hour Two hours later the set temperature will maintain as a constant and the fan speed is kept at low speed Heating The set temperature decrease 1 C per hour Two hours later the set temperature will maintain as a constant and the air circulation is kept at low speed Anti cold air function takes precedence over all Auto The economic running function operates in accordance with selected running mode by auto mode 9 15 Auto restart function In case of a sudden power failure this function automatically sets the unit to previous settings before the power failure when power returns 9 16 Models and Parameters Model 42HQE009QC 42HQE012QC 38YE009QC 38YE012QC gare 10A 12A Grig 8A 8 5A FAN 6 5A 7 5A IRESTORE 4 5A 6 5A IDEFROST 3 5A 5 0A ES 28 34 ma 32 37 ces 30 33 e 26 22 TE5 4 TE6 10 mn 60 62 a 53 53 ras 50 52 THperrost 15 15 TMberrosT 16 16 TLperrost 1 7 17
2. Temp down T gt TE5 On On Ts TES gt 5 Minutes Off Off 9 7 Dehumidifying mode 9 7 1The 4 way valve is off in dehumidifying mode Bi aag and Indoor Fan actions in dehumidifying mode Conditions Indoor Fan Fan Indoor Fan Compressor and Outdoor Fan Compressor and Outdoor Fan Outdoor Fan ON 6minutes TA TS 2 BREEZE OFF 4minutes ON b5minutes BREEZE OFF 5minutes LOW ON 4minutes BREEZE OFF 6minutes 9 7 3Low room temperature protection When room temperature decreases to below 10 C compressor and outdoor fan will stop indoor fan is Breeze Dehumidifying operation will be resumed when room temperature restores to over 13 C TS lt TA lt TS 2 Repeat on and off cycle 9 7 4At dehumidifying mode the anti freezing function of the indoor heat exchanger is the same as that of cooling mode 9 7 5At dehumidifying mode the action of indoor fan is the same as that of air only mode 9 8 Heating mode 9 8 1Generally the 4 way valve is open in heating mode but it is closed in defrosting mode 4 way valve must delay 2 minutes compared with compressor if the compressor changed into non heating mode or turned off 4 way valve doesn t delay in dehumidifying mode 9 8 2Generally the outdoor fan is turned off with the on off action of compressor in heating mode except for the defrosting mode or the end of defrost 9 8 3Action of compressor and outdoor fan motor at heating mode compressor must run
3. the following D amp D A and B are satisfied A The compressor keeps running for 40 minutes or more B The temperature difference of evaporator and room temperature meets one of the following Temp of evaporator room temp Fan speed is high lt THberrosT Fan speed is mid lt TMberrost Fan speed is low lt TLoerrosT Breeze Meet only if it is Breeze 2 Calculate from the end of latest defrost evaporator high temp protection only closes outdoor fan with the compressor still running Add up to 90 minutes 9 9 2 Defrosting time If the temp difference condition 1 is satisfied for less than 40 minutes this can be regarded as severe frosting The defrosting time is 10 minutes If the temp difference condition 2 is satisfied for more than 40 minutes the defrosting time is 6 minutes If the temp difference condition 1 is satisfied out of 40 minutes generally the defrosting time is 6 minutes after three continuous 6 minute defrost the fourth should be 10 minutes defrost The circulation is as following 6 minute defrost 6 minute defrost 6 minute defrost 10 minute O 9 9 3 Ending condition of defrosting Ifone of following conditions is satisfied end the defrost and turn into heating mode A The defrost time has reached to 6 or 10 minutes B The compressor current has reached to Iperrost Or above Iperost differs in different models 9 9 4 Defrosting Actions i Defrost 100r 6minute
4. 46 57 22 11 5 49 3 5896 4 44 23 10 973 50 3 451 3 41 59 24 10 474 51 3 3185 2 39 82 25 10 52 3 1918 1 37 2 26 9 5507 53 3 0707 0 35 2 27 9 1245 54 2 959 1 33 33 28 8 7198 55 2 8442 2 31 56 29 8 3357 56 2 7382 3 29 91 30 7 9708 57 2 6368 4 28 35 31 7 6241 58 2 5397 5 26 88 32 7 2946 59 2 4468 6 25 5 33 6 9814 60 2 3577 7 24 19 34 6 6835 61 2 2725 8 22 57 35 6 4002 62 2 1907 9 21 81 36 6 1306 63 2 1124 10 20 72 37 5 8736 64 2 0373 11 19 69 38 5 6296 65 1 9653 12 18 72 39 5 3969 66 1 8963 13 17 8 40 5 1752 67 1 830 14 16 93 41 4 9639 68 1 7665 15 16 12 42 4 7625 69 1 7055 16 15 34 43 4 5705 70 1 6469 7 2 Compressor windings resistance run amp start winding 20 C Compressor model PA108X1C 4DZDE PA145X2C 4FT Winding 1 Main 3 7545 Q 2 3515 Q Winding 2 Sub 4 7515 Q 3 2245 Q 7 3 Indoor fan motor windings resistance 20 C Motor model RPG13H RPG20D Winding 1 Main 385 8 360 8 Winding 2 Sub 400 8 291 8 7 4 Outdoor fan motor windings resistance 20 C Motor model YDK24 6T YDK24 6F Winding 1 Main 170 8 440 8 Winding 2 Sub 195 8 215 8 0 8 Troubleshooting For all heat pump model Failure phenomenon Operation lamp Timer lamp Defrosting lamp Over current protection of the compressor occurs 4 times x X x Indoor fan speed has been out of control for over 1 mi
5. Ed i NG pang j CM pP RD i A L TA AN FM PROA f We A 3 d 4 N 1 di COMPRESSOR 7 T FAN 1 CAPACITOR EL L CAPACITOR Y G BL i E Ce J MOTOR FOR COMPRESSOR MOTOR FOR FAN ng I a c gt g PA DETECT i T KO cang MAIN BOARD CNSR CMI A 6 2 42HQE012QC 38YE012QC BROWN LOR BLACK PONER SURELY Paa Y G OR GREEN de N E BROWN se j BROW E a5 S no a CURRENT DETECT ii ELL o a 0 MAIN BOARD a sg a maak DISPLAY DISPLAY mp K E a YIG is gt INOTES i ANGIN UP TO THE IEC STANDARDS BROWN BLUE Y G OR THE UL TO OUTDOOR UNIT STANDARDS BLACK WHITE GREEN OUTDOOR ELECTRIC WIRING DIAGRAM TO INDOOR UNIT OUTDOOR UNIT Y G H S RD BK BR BL va ve BL BLUE RD RED TERMINAL BLOCK YELLOW Y C GREEN BR EROWI BK r Q N I OVERLOAD PROTECTION J NI J RD Fa CM K RDA L L Y Y B CAPACITOR i T CAPACITOR Y G BL MOTOR FOR COMPRESSOR MOTOR FOR FAN 7 Specification of electrical parts 7 1 Temperature resistance of room temp sensor amp pipe temp sensor Temperature Resistance Temperature Resistance Temperature Resistance C Ko CC Ko T KQ 10 62 28 17 14 618 44 4 3874 9 58 71 18 13 918 45 4 2126 8 56 37 19 13 263 46 4 0459 7 52 24 20 12 643 47 3 8867 6 49 32 21 12 056 48 3 7348 5
6. OSHIBA Capacity Btu h 8820 12045 apresso Input W 900 1225 Rated current RLA A 4 1 5 5 B160 135 241E MRA UP3REO591 T56 IThermal protector 13430 9087 INTERNAL IOL Capacitor uF 25 35 Refrigerant oil ml 350 480 Model RPG13H RPG20D Brand Welling Welling Indoor fan motor Input W 36 5 44 Capacitor uF 1 2 1 5 Speed hi mi lo r min 1150 1050 950 1180 900 750 la Number of rows 2 2 b Tube pitch a xrow pitch b mm 21x13 37 21x13 37 c Fin spacing mm 1 3 1 3 Indoor coil d Fin type code Hydrophilic aluminium Hydrophilic aluminium le Tube outside dia and type mm 7 innergroove tube 7 innergroove tube f Coil length x height x width mm 578X252X26 74 655x315x26 74 ig Number of circuits 2 2 Indoor fan Type mm Crossflow Crossflow Indoor air flow Hi Mi Lo m3 h 450 400 350 642 470 380 Indoor Sound pressure Hi Mi Lo 38 36 33 41 36 30 LPA cooling bad Indoor unit Dimension W H D mm 750x250x188 815X280X195 Packing W H D mm 830x336x280 915X360X275 Net Gross weight Kg 12 5 15 14 19 5 Model YDK24 6T YDK24 6F Brand Welling WELLING Outdoor fan motor Input W 56 56 Capacitor uF 3 25 Speed r min 840 800 la Number of rows 1 1 6 b Tube pitch a xrow pitch b mm 25 4x22 21x13 37 c Fin spacing mm 1 4 1 5 Outdoor coil d Fin type code Hydrophilic aluminium Hydrophilic aluminium le Tube outside dia and type mm 09 53 innegroove tube 067 innerg
7. Service Manual Split Wall Mounted Type Room Air Conditioner ALLEGRO PLUS SERIES Model applied 42HOE0090C 38YE0090C 42HQE012QC 38YE012QC 00 O QE QM Contents FEES EET 3 Tse e d DIMENSION PARA TA AT 6 Refrigeration cycle diagram maa 9 Operation HMS puna E AA ANA AA AA 10 Wiring diagram iii ia 11 Specification of electrical paris sssssseeeeeeeessssseeeeeeee essere seene eenn eee 13 Troubleshooting iii e 14 Electronic function Ka KAKANAN GNG 14 1 Features 1 1 Compact design 1 2 Ouiet operation 1 3 Anti icing function at cooling mode 1 4 Anti cold air function at heating mode 1 5 Auto defrosting and heating recovering function at heating mode 1 6 Outdoor unit overload current protection 1 7 Restart function 1 8 24 hours on off mode time setting 1 9 Error self diagnosis function 1 10 Quickly connected piping and cable 2 Specification Power supply Ph V Hz 1 220 240V 50Hz 1 220 240V 50Hz Capacity w 2500 3500 Rated Input 890 1250 Cooling Rated current A 4 2 5 5 EER W W 2 81 2 81 Capacity w 2900 4000 Rated Input 900 1250 Heating Rated current A 4 2 5 4 COP W W 3 21 3 21 Moisture Removal L h 1 0 1 2 Max input consumption 1200 1500 Max current A 6 8 Starting current 21 7 33 Model PA108X1C 4DZDE PA145X2C 4FT Type Rotary Rotary Brand TOSHIBA T
8. YE012QC 4 Refrigeration cycle diagram Cooling amp heating outdoor unit Indoor unit a Quick connecter Auxiliary accumulator for 12K Sensor of room temp K Heat exchanger 4 way valve Heat exchanger Compressor Sensor of heat exchanger temp Quick connecter Capillary a One way valve 5 Operation limits 5 1 Cooling operation Outdoor air temp C DB 45 40 COOLING 35 30 25 20 10 15 20 25 30 35 40 Indoor air temp C DB Note The chart is the result from the continuous operation under constant air temperature conditions However excludes the initial pull down stage 5 2 Heating operation Indoor air temp C DB 30 25 20 15 10 5 5 15 25 Outdoor air temp C DB Note The chart is the result from the continuous operation under constant air temperature conditions However excludes the initial pull down stage 6 Wiring diagram 6 1 SISISISIS 42HQE009QC 38YE009QC PONER SUPPLY b BROWN OR BLACK ls L F BLUE OR GREEN t NE 1 OLD var ama KK EIK L YIG INDOOR UNIT 5 THE COLOR OF POWER SUPPLY CORD L N E MEASURES Soa Ta STANDARDS BROWN BLUE Y G OR THE UL EEN OUTDOOR ELECTRIC WIRING DIAGRAM TO INDOOR UNIT OUTDOOR UNIT overtop T PROTECTION Ee RD
9. for 7 minutes after starting and then judge temperature Meanwhile other protections are still valid Condition Compressor Outdoor fan Room temp up T gt Ts 3 off Off T lt Ts 3 On On Room temp down Ts Ts 2 On On T gt Ts 2 Off Off 9 8 4Indoor Fan actions at heating mode Condition Indoor fan speed T Indoor exchanger temp Indoor exchanger temp up T lt TE1 Off TE1 lt T lt TE2 Breeze T gt TE2 Setting fan speed Indoor exchanger temp down T gt TE3 Setting fan speed TE3 lt T lt TE4 Breeze T lt TE4 Off 9 8 5Auto wind at heating mode Condition Indoor fan speed Indoor Fan can be set at HIGH MID LOW AUTO by using a wind function prevails Anti cold wind control function at heating mode remote controller but Anti cold T Indoor Temp Setting Temp Room temp up T lt 2 High T gt 2 Mid Room temp down T gt 0 Mid T lt 0 High 9 8 6Indoor evaporator high temperature protection at heating mode Condition Compressor Outdoor fan T Indoor exchanger temp Indoor exchanger temp up T lt TE8 On On TE8 lt T lt TE7 On Off T gt TE7 Off Off Indoor exchanger temp down T gt TE9 Off Off T lt TE9 On On 9 8 7 The louver opens to Standard Angle ANGLHEAT when power is on for the first time 9 9 Defrosting operation Ava ilable for heating only 9 9 1Defrosting condition Defrosting starts when either of
10. i cold air from Setting Fan Speed to Breeze temperature TE4 Anti cold air from Breeze to Fan Off temperature TE5 Evaporator low temperature protection entering temperature TE6 Evaporator low temperature protection restoring temperature TE7 Evaporator high temperature protection compressor off temperature TE8 Evaporator high temperature protection fan off temperature TE9 Evaporator high temperature protection restoring temperature 9 3 Systematic functions Remote receiving Testing and forced run Position set for indoor unit wind vane LED displaying and alarm On or off Timer Protection for the compressor Current protection High temperature protection of indoor heat exchanger at heating mode Auto defrosting and heating recovery at heating mode Anti cold air at heating mode Anti frozen at heating mode 9 4 Protection The compressor functions protection with a delay of three minutes Sensor protection at open circuit and breaking disconnection 9 4 1 Temperature Fuse break protection 9 4 2 Fan Speed is out of control When Indoor Fan Speed is too high higher than High Fan 300RPM or too low lower than 400RPM the unit stops and LED displays failure information and can t returns to normal operation automatically 9 4 3 Cross Zero signal error warning If there is no Cross Zero signals in 4 minutes the unit stops and LED displays failure information and can t returns to normal operation automatically 9 4 4 The current protection of the co
11. mpressor Condition Indoor fan Compressor Outdoor fan Remark Current up I lt IRESTORE On On On IRESTORE SIS Iran On On Off Heating mode Low speed On On Cooling mode Iran SISlsmin Off Off After 5 Minutes Ismin lt l lt lasec Off Off After 3 Seconds Current down lsmin lt I lt I3sec Off Off After 3 Seconds Iran SMIN Off Off After 5 Minutes IRestore SIS FAN On On Off Heating mode Low speed On On Cooling mode l lt IresTORE On On On If compressor turns off for continuously 4 times due to current protection in 5 minutes since Compressor On the unit stops and LED displays failure information and can t returns to normal operation automatically 9 5 Fan only mode Fan speed is high mid low Auto 9 6 Cooling mode The 4 way valve is closed at cooling mode The action of the compressor and the outdoor fan Condition Compressor Outdoor fan Temp up T gt Ts 1 On On T lt Ts 1 Off Off Temp down T gt Ts On On T lt Ts Off Off Auto fan at cooling mode Condition Indoor fan speed T Indoor Temp Setting Temp Temp up T lt 3 Low 3 lt T lt 5 Mid T gt 5 High Temp down T gt 3 High 1 lt T lt 3 Mid T lt 1 Low Anti freezing control to indoor evaporator at cooling mode T evaporator temp Condition Compressor Outdoor fan Temp Time Temp up T gt TE6 On On Ts TE6 55 Minutes Off Off
12. nute X x Ww No over zero signal x x Ww Temp sensor on indoor evaporator is open circuit or short o v da circuit Indoor room temp sensor is open circuit or short circuit X Y X EEROM error On Ww Xx X Extinguish Flash at 5Hz 9 Electronic function 9 1 Electric Control working environment 9 1 1 Input voltage 175 253V 9 1 2 Input power frequency 50Hz 9 1 3 Ambient temperature 7 C 43 C 9 1 4 Indoor fan normal working amp is less than 1A 9 1 5 Outdoor fan Normal working amp is less than 1 5A 9 1 6 Four way valve normal working amp is less than 1A 9 1 7 Swing motor DC12V 9 1 8 Compressor single phase power supply Its normal working amp is less than 15A 9 2 Proper symbols and their meanings TA Indoor ambient temperature TE Indoor evaporator temperature TS Setting temperature through the remote controller lasec Self protection amp of compressor continue three seconds until turns off the compressor Ismin Self protection amp of compressor continue five minutes until turns off the compressor Iran Self protection amp of outdoor fan indoor fans when they change from higher wind to lower wind Irestore Amp self protection return value THperrost High wind defrosting temperature difference TMberrost Middle wind defrosting temperature difference TLperrost Low wind defrosting temperature difference TE1 Anti cold air from Fan Off to Breeze temperature TE2 Anti cold air from Breeze to Setting Fan Speed temperature TE3 Ant
13. roove tube f Coil length x height x width mm 684x508x22 775x504x26 74 ig Number of circuits 2 4 Outdoor fan Type mm Propeller Propeller Outdoor air flow m3 h 1800 2000 Outdoor Sound pressure dB A 53 54 LPA cooling Dimension W H D mm 700X540X225 780X540X245 Outdoor unit Packing W H D mm 815X580X325 910X575X335 Net Gross weight Kg 27 30 34 5 36 5 Refrigerant type R410A g 850 1000 Design pressure MPa 4 2 4 2 Refrigerant piping Liquid side Gas side Quick Connection 4m Quick Connection 4m Expansion device Main mm 2 5 1 3 700 3 2 1 7 1100 Capillary Sub mm 2 5 1 3 950 2 5 1 5 1100 Operation temp CC 17 30 17 30 Ambient temp CC 7 43 7 43 Application area m2 14 21 18 26 Remarks 1 Cooling capacities are based on indoor air temp 27 C DB 19 C WB and outdoor air temp 35 C DB and 24 C WB Heating capacities are based on indoor air temp 20 C DB 15 C WB and outdoor air temp 7 C DB and 6C WB 2 Indoor Sound Pressure level is measured in free field JIS 9612 std at 1m distance Outdoor Sound Pressure level is measured in hemispherical field at 4m distance from the unit these values are normally somewhat different as a result of ambient condition 3 Dimensions 3 1 Indoor unit 42HQE009QC 42HOEO09 00 Indoor unit outline Installation plate 150 mm or more to ceiling 120 mm or more to wall 6 Left refrigerant pipe hole Indoor unit 42HQE012QC 3 2 Outdoor unit 38YE009QC 38
14. s gt 45 gt 258 Compressor 4 way Valve Outdoor Fan Indoor Fan 9 10 Automatic operation mode 9 10 1 The air conditioner automatically selects one of the following operation modes cooling heating or fan only according to the temp difference between room temp TA and set temp TS TA TS Operation mode TA TS52 C Cooling 1C lt TA TS lt 2 C Fan only TA TSs 1C Heating Fan only for cooling only type 9 10 2 The indoor fan blows automatically in corresponding selected mode 9 10 3 The motion of indoor fan s blade should accord with the selected operation mode 9 10 4 One mode should be carried out for at least 15 minutes once selected If the compressor cannot start for 15 minutes reselect the operation mode according to the room temp and set temp or reselect when the set temp varies 9 11 Forced cooling function 9 11 1 Select forced cooling function with the forced cooling button or the switch 9 11 2 The compressor is unconditionally turned on after 30 minutes cooling operation whose fan mode is set as low the A C operates at the DRY mode with a set temp of 24 C 9 11 3 All protections of remote control cooling are available at forced cooling operation 9 12 Forced Auto function Select forced auto function with the forced auto button or the switch In forced auto status the A C operates like auto mode with a set temp of 24 C 9 13 Timer Function 9 14 Economic Running 9