Home

HoyerPro 600 Manual

image

Contents

1. beeper will sound continuously Once the beeping stops both buttons should be released and the lift sequence will commence Maintaining the Lift Maintenance Schedule The lift requires regular maintenance Set up and follow a maintenance schedule The following chart represents minimum maintenance 1 AS Nesded Each Monil Gearing v If the inspection shows damage or excessive wear remove the lift from service until the repair is made Refer to Repair Parts and Service section Lubrication The internal ring gear requires lubrication annually For optimal performance NYE Rheolube 380 or equivalent industrial grade grease should be used This must be performed by a qualified technician only Cleaning the Lift Clean all surfaces of the lift with a damp soft cloth and a mild detergent Use a stiff bristled brush if necessary Wipe the lift using a damp cloth Dry the lift with a towel Joerns Healthcare recommends inspecting the lift for obvious damage as you disinfect it Inspecting the Lift Have your service technician check the following Are all components present Does the spreader bar move up and down smoothly Are the lift components free of excessive wear Do all controls function properly Do all safety cutouts function properly Are the slings in good condition with no cuts or frayed edges Are all screws nuts bolts and pins present and securely in place Does the lift traverse smooth
2. Record see manufacturing rights reproduction use rights and sales use rights thereto and to any article disclosed Maintenance Record therein except to the extent those rights are expressly granted to others or where not applicable to vendor proprietary parts Important Precautions Ak Danger Electric shock can cause death or serious injury Charge the lift batteries only as described in this manual Ak Warning Improper use of the lift can cause injury Use the lift only for the purpose described in this manual Ak Warning Untrained operators can cause injury or be injured Permit only trained personnel to operate the lift Ak Warning Improper operation can cause injury Operate the lift only as described in this manual Ak Warning Helpers can cause injury or be injured Maintain control of the lift operate the controls and direct any helpers Ak Warning Improper maintenance can cause injury Maintain the lift only as described in this manual Jak Warning Improper parts and service can cause injury Use only Joerns Healthcare parts and Joerns Healthcare approved items on the lift Proprietary Notice Important Precautions Return to Charge Option Repair Parts and Service Limited Warranty Le
3. have the serial number of your Joerns Healthcare product available when calling Customer Service and include it in all written communications Canadian Office 1000 Clarke Road Suite 6 London ON Canada N5V 3A9 P 866 546 1151 F 519 451 8662 2010 Joerns Healthcare 6110096 RevA 10 1102 Post Acute Acute HomeCare VA Government 5001 Joerns Drive 19748 Dearborn Street Stevens Point WI 54481 Chatsworth CA 91311 P 800 826 0270 P 800 966 6662 F 800 457 8827 F 800 232 9796 Joerns Nu Healthcare www joerns com email info joerns com
4. 4 Healthcare User Service Manual Joerns Lifting and Repositioning Hoyer Pro6OO Ceiling Lift To avoid injury read user s manual before using redefining patient handling r Joerns Lifting and Repositioning Hoyer Pro600 Ceiling Lift Disclaimer Table of Contents This manual contains general instruction of the use operation and care of this product The instructions are Disclaimer cccccceceseecesneeeeeeseeeeeeeeenaeeenes not all inclusive Safe and proper use of this product is solely at the discretion of the user Safety information is included as a service to the user All other safety measures taken by the user should be within and under consideration of applicable regulations It is Learning About the Lift recommended that training on the proper use of this product be provided before using this product in an Operator Skills and Training Eau inin a a a a xa nel Using the Lift i i kk sakkkkkkikkkae actual situation Retain this manual for future reference Include it with the product in the event of transfer to new users Additional free copies are available upon request from Maintaining the Lift Customer Service Maintaining the Track Proprietary Notice The information disclosed in this manual is the Lift Checklist property of Joerns Healthcare Joerns Healthcare reserves all patent rights proprietary design rights Training
5. arning About the Lift Lift Description The Hoyer Pro600 is a device for lifting and transporting a patient The lift is intended for professional use by trained operators Additional help may be necessary when using the lift General specifications are rounded to the nearest whole number For detailed specifications contact Joerns Healthcare Customer Service at 800 826 0270 Joerns Healthcare reserves the right to change specifications without notice 1 Hand Controller Used to control raise and lower functions as well as traverse functions on power traverse models 2 Spreader Bar Assembly Used as the main support for lifting the patient Sling can be directly looped to the hooks on the ends for two point attachment during certain transfer applications 3 Scale optional not shown Accurate to within 1 10th of a pound Features a LCD readout auto zeroing and the capability of displaying both pounds and kilograms 4 Side Suspender Bars Attached to spreader bar ends for use in four point sling attachments This is the most common transfer application for optimum patient comfort 5 Lifting Strap Attaches the spreader bar to the lifting motor 6 Emergency Lowering Pullcord This feature is to be used for lowering the patient only when all other attempts fail 7 On Off Switch and Emergency Stop Toggle Switch turns lift on and off Crear ride controls p wr traverse Note Thee controls nci am a second sai af C
6. ecommends a minimum of two trained operators Additional help may be necessary for some procedures or circumstances Refer to your company s policy 2 Follow standard patient handling procedures when operating the lift as defined by your company s policy 3 Stay with the patient at all times Using the Lift Controls To use these controls press the raise button to raise the patient Press the lower button to lower the patient Press either of the power traverse buttons to move forward or backward along the track Figure 2 Emergency Lowering In the event of a malfunction locate the emergency lowering cord ring Figure 3 and pull until fully extended Once extended pull on emergency lowering cord to safely lower patient to bed or chair Moving the Lift to the Patient Important Ensure that the lift is directly above patient prior to attaching sling Do not attach sling if lift is misaligned to the front back or either side If the Patient is in a Bed 1 With the sling in place lower the spreader bar until the side suspender bars are just above the patient s abdomen or lower chest Ensure that the spreader bar is parallel with the patient s shoulders Figure 4 Figure 2 Figure 3 Figure 4 Joerns Lifting and Repositioning En Hoyer Pro600 Ceiling Lift If the Patient is in a Chair 1 Ifthe patient is in a chair lock the chair s wheels if so equipped 2 With the sling in place lower the sp
7. ght front hook Figure 8 Lifting the Patient If the Patient is in a Bed or on the Floor 1 Once sling is attached to spreader bar raise the patient just enough to check the patient s safety and comfort Ensure that leg loops are not bunched up or twisted Ensure that leg loops are not riding up uncomfortably into patient s groin Once sling has been checked and adjusted if required continue to raise the patient to desired height Figure 9 Figure 8 2 As you raise the spreader bar have attendants use the sling to guide the patient If the Patient is in a Chair 1 Raise the patient just enough to check the patient s safety and comfort Ensure that leg loops are not bunched up or twisted Ensure that leg loops are not rising up uncomfortably into patient s groin Figure 10 2 Once sling has been checked and adjusted if required continue to raise the patient to desired height Transporting the Patient 1 Lift patient as previously described in this manual Ensure there are no obstructions in the path of travel 3 Depress the appropriate power traverse button on the hand controller if so equipped For the manual traverse models push or pull on the sling 4 Walk with the patient stabilizing them at the same time to ensure safety Figure 9 Figure 10 Lowering the Patient Lowering the Patient to a Bed 1 Lower the patient slowly to the bed Once the patient is fully supported by the bed disco
8. ly Is the main lifting strap in good condition with no cuts or fray Maintaining the Track The ceiling lift track system is an important part of your overall lifting system All tracks and related components require regular maintenance inspection and load testing Any loose fittings must be repaired prior to using the lift Any lateral or end to end movement or deflection in the track is a sign of abnormal wear Do not use the lift if any of these conditions arise Have your track system professionally serviced prior to putting the lift back into service Annual track inspections and load testing are imperative and required Never use any track system that has not been load tested in the last 12 months Inspecting Ceiling Lift Straps Important Aid for inspecting ceiling lift straps Figure 13 If any of the below conditions are discovered remove the lift immediately and contact Joerns Healthcare 800 826 0270 Repair Parts and Service To order parts or for professional lift repair contact Joerns Healthcare at 800 826 0270 Joerns Healthcare or an approved dealer are the only agents authorized to manage service or repair this product Prep apres l lu ar ta ra war mark Figure 13 Joerns Lifting and Repositioning Hoyer Pro600 Ceiling Lift Lifter Maintenance Checklist To be Inspected by User Every 2 Years Clean Lift as described in Maintaining the Lift section Inspect lifting strap fo
9. nnect the sling from the lift 2 Roll the patient on to his her side and slide the sling from beneath the patient Figure 11 Lowering the Patient to a Chair 1 If lowering the patient into a wheelchair lock the wheelchair s wheels 2 Position the patient over the chair 3 Lower the patient slowly into the chair Have the attendant guide the patient into the chair 4 As the patient settles in the chair have the attendant grasp the handle on the back of the sling and pull upward gently allowing the patient to sit in an upright position Figure 12 5 Once the patient is fully supported by the chair disconnect the sling from the lift Note If lowering the patient to a toilet use a toileting sling This type of sling can be kept attached to the patient while they use the toilet 6 When finished transporting the patient remove the sling from behind the patient Figure 11 Joerns Lifting and Repositioning En Hoyer Pro600 Ceiling Lift Charging the Batteries Important Totally discharging the lift batteries reduces battery life 1 Charge the lift when it is not in use or if the orange or red LED s are illuminated on the battery indicator 2 Raise the spreader bar to a safe height 3 Depress the traverse button on the hand controller or manually move the lift 4 Move the lift until it reaches the charging station 5 If batteries are discharged to a level where the lift will not move manually
10. o be free from defects in materials and workmanship for one year except as follows External finishes gelcoat decals paint etc are warranted for 90 days Soft goods webbing vinyl foam etc are warranted for 90 days Repairs and services are warranted for 90 days or until the end of the time period s above whichever comes last This limited warranty applies when you use and care for the product properly If the product is not used and cared for properly the warranty is void The warranty period begins the day the product is shipped from Joerns Healthcare or the day you received it if you have proof of the delivery date Shipping charges and travel time are not covered by the limited warranty We are not liable for shipping damages or damages sustained through using the product Limited Warranty Obligation If a product or part is proven to be defective Joerns Healthcare will repair or replace it At our option we will refund the product s purchase price The purchaser accepts these terms in lieu of all damages This is a summary of the limited warranty The actual terms and conditions of the limited warranty and the limitations of liability and disclaimers are available upon request by calling 800 826 0270 Customer Service Customer Service Product Support is an important aspect of each Joerns Healthcare product For assistance with the lift contact Joerns Healthcare Customer Service at 800 826 0270 Please
11. onte on manual avers modela Erergency Lowering Joerns Lifting and Repositioning EN Hoyer Pro600 Ceiling Lift Battery Level Indicator Gauge Allows the user to monitor battery levels at all times The readings should always be in the green zone If levels fall below green into yellow or red lift should be charged immediately The smart charge battery charging station makes overcharging impossible An audible tone will sound if batteries are at a critically low level Figure 1 Components r Joerns Lifting and Repositioning Hoyer Pro600 Ceiling Lift Operator Skills and Training Skills Operators need a working knowledge of patient handling procedures Operators need the ability to assist the patient Training Follow a training program designed by your training officer Read this manual Practice with the lift before using it in regular service Test each trainee s understanding of the lift Keep training records Use the convenient form on page 10 Using the Lift Before Placing the Lift in Service 1 Require all personnel who will work with the lift to read this manual 2 Assign appropriate personnel to confirm that the lift operates properly Have them follow instruction in Inspecting the Lift on page 8 3 Install 20A fuse supplied and attached to the trolley into the panel fuse holder located on the top surface of the plastic shroud General Guidelines for Use 1 Joerns r
12. pull it to the charging station 6 Charge the lift for at least two hours before returning it to service 7 The LED s will flash sequentially when proper charging is initiated Note Joerns Healthcare recommends that the lift remain connected to the battery charger any time it is not in use Using Additional Help Joerns recommends two trained operators He she may need additional help Refer to your company policy for safe patient handling Operators should maintain control of the lift and direct helpers Return to Charge Option RTC Pro600 Activating On Off To Activate ON Hold the lift button for 15 seconds The lift will beep twice This display will show Active To Activate OFF Hold the lift button for 15 seconds The lift will beep once The lift will show OFF The RTC sequence is to lift until the upper limit has been reached then traverse toward the charger until the charger has been detected or 34 seconds of maximum traverse time Lower for 10 seconds so that the spreader bar is easier to grab turn off and charge The RTC sequence can be stopped after the first 4 seconds of lift by hitting any switch The RTC will immediately stop if the lift current is greater than 5 amps cannot RTC if the lift has a load in it 7 r Joerns Lifting and Repositioning Hoyer Pro600 Ceiling Lift To Initiate RTC Press and hold the traverse left and right buttons at the same time for 4 seconds
13. r cuts and or fraying and or unravelled stitching Replace strap immediately if damaged Do not use lift if strap is damaged Inspect all spreader bar and side bar hardware for loose and or missing components Repair any deficiencies before using lift Inspect test hand controller functions Inspect test charging functions Inspect test all limit switch functions v TEE Re EBEN Lise PN LI N TI TT s mon LE BRI TT T famu EE HEN SSSR specrtestemergencylowerngandememenoystpfundons BE I Repacebateies Cd Celing lift Trak T inspect and tighten all track brackets j inspect and tighten all track end stops Cd m E Load test all tracks v Inspect for cuts tears fraying and unravelled stitching Immediately remove from service if damaged Inspect for signs of bleaching as per sling instructions Replace main lifting strap v Lifting and Repositioning Hoyer Pro600 Ceiling Lift Joerns Training Record Description o p Joerns Lifting and Repositioning Lj Hoyer Pro600 Ceiling Lift Maintenance Record LEE a NNNM Joerns Lifting and Repositioning m Hoyer Pro600 Ceiling Lift Joerns Healthcare Warranty Program for Joerns Hoyer Pro600 Thank you for purchasing the Hoyer Pro600 Ceiling Lift With proper care and maintenance you will enjoy many years of service from our carefully crafted product Joerns warrants the products we manufacture t
14. reader bar until the spreader bar is level with the patient s forehead and is 10 to 12 inches in front of the patient Figure 5 Attaching the Sling to the Lift Decide in what position the patient should be when lifted To lift the patient in a seated position use a shorter set of loops at the shoulders and a longer set of loops at the legs This places the patient s head higher than his her legs To lift in a reclined position use a longer set of loops at the shoulders and a shorter set of loops at the legs This will allow the patient s head to be level with his her legs Figure 6 Attach the back loops to the hanger by slipping the right back loop over the right back hook and the left back loop over the left back hook Note The left and right refer to the patient s left and right Configuring the Sling for Normal Use 1 Run the left leg strap under the patient s left leg up between the patient s legs and attach to the right front hook Figure 6 2 Runthe right leg strap under the patient s right leg up between the patient s legs and attach to the left front hook Figure 7 Figure 7 Figure 5 r Joerns Lifting and Repositioning Hoyer Pro600 Ceiling Lift Configuring the Sling for Impairments such as Groin Injury 1 Run the right leg strap under both of the patient s legs and attach to the left front hook 2 Run the left leg strap under both of the patient s legs and attach to the ri