Home
Stature User Manual
Contents
1. 1 Hoyer Stature Patient Lift Battery Control Pack Mast Extrusion Push Handle Foot Push Pad Straight Line R Steering Device gt S Motor Gearbox Rear Castor braked Front Castor non braked READ AND UNDERSTAND THE INSTRUCTIONS IN THIS MANUAL BEFORE USING YOUR STATURE 3 294000 10062 Rev A Fl Hoyer English Stature 2 Introduction About Your Lift The Hoyer Stature is an electrically operated patient lift Each Stature lift is fully assembled load tested and certified before being packed shipped The packing consists of a strong purpose built carton that is used for both export and domestic markets to ensure the safe arrival of the lift A number of documents are supplied in a wallet which is packed with each lift and should be kept safely for future reference USER MANUAL CUSTOMER SATISFACTION CARD Europe only TEST CERTIFICATE DEALER GUARANTEE CARD Europe only PACKING CHECK LIST The TEST CERTIFICATE is an important document and may be required for your insurance records It is valid for six months and after it has expired the lift should be inspected and serviced per the maintenance schedule by a competent authorized engineer Servicing and periodic testing can be carried out by your authorized supplier Please ensure your lift is included in their maintenance schedule If you are at all unsure what your local market servicing requirements are please check with your deale
2. Lift Strap Check Lift Strap 21 294000 10062 Rev A Ki Hoyer English Stature 9 Technical Specifications Safe Working Load 500 Ibs 227 kgs Maximum Overall Length 54 7 inches 1390 mm Minimum Overall Length nennen 50 8 inches 1290 mm Maximum Overall Height neen 83 8 inches 2130 mm Minimum Overall Height nennen 76 6 inches 1945 mm Height at Maximum Reach eenen 77 8 inches 1975 mm Reach at Maximum Height eenen 24 6 inches 625 mm Reach at Minimum Height eenen 24 6 inches 625 mm Maximum REACH anne 24 6 inches 625 mm Tumming RAUS resereven en tenets sta 61 0 inches 1550 mm Legs Open External Width 93 9 inches 1360 mm Legs Open Internal Wd 48 4 inches 1230 mm Legs Closed External Width oo cence 29 9 inches 760 mm Legs Closed Internal Width oo eee 25 1 inches 640 mm Overall Height of LEGS nennen evene eneneenen 4 3 inches 110 mm Ground Clearance 1 2 inches 30 mm Front TW Bee 4 inches 100 mm Rear Braked Caetors ENEE 4 inches 100 mm Reach center of spreader bar to the front of the mast 4 Point Position Cradle measurement to top of location pins NOTE 4 point positioning cradle is standard fitment with the Stature lift Cradle Max H ight issii nriran 61 inches 1550 mm Cradle Min Height usable nnen 15 4 inches 390 mm 6 Point Spreader Bar measurement to top of location pins NOTE 6 point positioning cradle is optional for the Stature lift Spreader Bar Max H
3. Service Manual It is strongly X recommended the testing is carried out by an authorized service dealer 11 BASE AND WHEELS Ensure base is even and level all four wheels are on the floor 12 SLINGS Check for wear and fraying 13 LUBRICATION Oil pivot joints including mast and boom connections spreader bar joint only if required 14 HAND SET Ensure plugged fully into controller vv 15 FIXINGS Check all nuts bolts screws and fasteners for excessive wear and for tightness Replace as required HKH 20 294000 10062 Rev A English kloyer Stature THESE CHECKS SHOULD INCLUDE v Required X Recommended 6 months in North America 16 QUICK RELEASE PIN Ensure the pin is securely fitted before lifting by pressing the barbed end 17 LIFTING STRAP Your lift strap should be checked at service intervals for any sign of wear ideally every six months In order to view the strap it is recommended to remove the cap at the top of the mast cycle the lift in both directions whilst observing the condition of the strap If you see any wear v fraying creasing or similar it is recommended an authorized Joerns Healthcare Dealer or qualified competent service engineer replaces the strap IMMEDIATELY For details regarding strap maintenance and replacement please request our detailed service guide See below for details Service Intervals Initially lt Before Use S lt Check
4. correct size and capacity e NEVER use a sling which is frayed or damaged e ALWAYS fit the sling according to the instructions provided user instructions e ALWAYS ensure sling straps DO NOT get caught around the legs of the hoist e ALWAYS carry out lifting operations according to the instructions in the user manual e NEVER disconnect or bypass a control or safety feature because it seems easier to operate the lift e DO NOT lift a patient with the castor brakes on Always let the lift find the correct center of gravity e DO NOT attempt to manoeuvre the lift by pushing on the mast boom or patient e ALWAYS manoeuvre the lift with the push handle located on the mast A foot push pad is also provided on the base of the hoist e ALWAYS lower the patient to the lowest comfortable position before transfers e DO NOT push a loaded lift at speeds which exceed a slow walking pace 3 Km hour 0 8 metres second H 294000 10062 Rev A mover English Stature e DO NOT push the lift over uneven or rough ground Particularly if loaded e DO NOT attempt to push pull a loaded lift over a floor obstruction e NEVER force an operating safety control All controls are easy to use and do not require excessive force e DO NOT park a loaded lift on ANY sloping surface e DO NOT use electric lifts in a shower e DO NOT charge an electric lift in a bathroom or shower room e DO NOT lift a patient unless you are trained and competen
5. engaged Click into place DISASSEMBLY The lift should not be disassembled unless for service repair or transport if necessary If disassembly is necessary follow the assembly instructions in reverse sequence 7 294000 10062 Rev A Fl Over English Stature ALWAYS CHECK THE FOLLOWING BEFORE OPERATION Push the open and close buttons on the hand control to confirm that the legs of the lift open and close satisfactorily e Push the up and down buttons on the hand control to confirm that the boom rises and lowers satisfactorily 8 294000 10062 Rev A English Moyer Stature 4 Safety Precautions Please read and follow the safety precautions listed below Following these few basic safety precautions will make lifting operations easy and trouble free WARNING e ALWAYS check the safe working load of the lift is suitable for the weight of the patient e DO NOT exceed the safe working load of the hoist as an electrical current limiting device will activate preventing use of the hoist e ALWAYS plan your lifting operations before commencing e ALWAYS carry out the DAILY CHECK LIST before using the lift e ALWAYS familiarise yourself with the operating control and safety features of a lift before lifting a patient e DO NOT use a sling unless it is recommended for use with the lift e ALWAYS check the sling is suitable for the particular patient and is of the
6. opened to enable access around armchairs or wheelchairs For transferring and negotiating narrow doorways and passages the lift legs should be in the closed position Electric leg adjustment is achieved by pressing the appropriate buttons on the hand control The legs will be locked whenever the hand control switch is released 2 Castors and Braking The lift has two braked castors which can be applied for parking When lifting the castors should be left free and un braked The lift will then be able to move to the center of gravity If the brakes are applied it is the patient that will swing to the center of gravity and this may prove disconcerting and uncomfortable Attached to the rear castor is a straight line steering device which when applied to the castor will facilitate straight line movement 3 Raising and lowering the boom The movement of the boom carriage is achieved by a powerful motor gearbox which is controlled by a simple hand control unit The hand control has two buttons with directional arrows UP and DOWN SW The motor gearbox stops automatically at the limit of travel in both directions The hand control plugs into a socket at the base of the control box SAFETY NOTE The downward movement of the boom will stop if the lift senses that the patient has encountered an obstruction 4 Emergency Stop The red Emergency Stop Button is located on the front of the control box and is activated by pressing in This will cut a
7. to ensure the spreader bar cradle is safely locked into position before use CONNECTION To connect raise the spreader bar cradle up toward the boom slot Insert the pin sleeve through the plastic end cap and to support the spreader bar cradle Once aligned in the boom slot reinsert the quick release pin fully into the sleeve until it locks into position YOU MUST CHECK THAT THE PIN IS SECURELY FITTED To do this press your finger into the barbed end If the pin remains stationary the lift is safe to use 15 294000 10062 Rev A Hoyer English Stature REMOVAL CAUTION Be sure to support the weight of the spreader bar cradle before removing pin To detach pin depress the spring barb using a flat blade electrical screw driver or similar and pull the pin out Support the spreader bar cradle and then pull the pin sleeve in the opposite direction removing it completely from the boom This will release the spreader bar completely 16 294000 10062 Rev A English Meyer Stature 7 Charging Instructions The batteries are located in the power pack and are charged via an off board desktop charger unit Hand Control Legs Open Close Boom Raise Lower Control Box Emergency Stop Raise Lower When the battery pack needs charging it is removed from the lift and fitted to an off board charging unit 1 Remove the power pack from the lift The pack is retained by a simple latch at the top of the power pack
8. Hoyer Hoyer Stature User Instruction Manual amp Warranty To avoid injury read user manual prior to use Hoyer Stature Manuel de l utilisateur et garantie Afin d viter tout accident veuillez lire attentivement la notice avant utilisation Manual de Instrucciones y Garantia para el Usuario Para evitar posibles da os lea previamente el manual de usuario Hoyer Stature Benutzerhandbuch und Garantie Um Verletzungen zu vermeiden lesen Sie bitte die Gebrauchsanweisung vor der ersten Benutzung Hoyer Stature E mmJoerns SMHealthcare Redefining patient handling Fl ver English Stature Mianufacturer s Contact Details Hoyer USA Joerns Healthcare Inc 2100 Design Road Suite 100 Arlington TX 76014 USA Tel 800 826 0270 Fax 800 457 8827 www joerns com Contents 1 Hoyer Stature Patient Ef een anenennnnmmeraennaneeme 3 2 Introduction About Your Um 4 3 Assembly and Commissioning Instruchons A 5 4 Safety Precautions varanen nevera 9 5 Operating Instructions nnee een nenenenenenen enen venenenenenenenenvenenenenenenenennenenenenenenenen venen 11 6 Removal of Spreader Bar Cradle Systems 15 ihe Charging InSh CUONS sein iara AE EEREN EERE E 17 8 Maintenance Schedule amp Daily Check List eneen venrenenenenenten enn 19 9 Technical Specifications ENEE NENNEN 22 19 E Cu 24 2 294000 10062 Rev A English OVER Stature
9. Lift the latch and the power pack will be released 2 Fit the power pack to the charging unit The location and latching of the power pack to the charger is the same system as used on the lift 3 Plug the charger mains plug into a suitable mains outlet 4 Charging is automatic and will fully charge the batteries over a period of eight to twelve hours Note Even if the charger is left plugged in for extended periods it will not allow the batteries to overcharge a Green Light Indicates main power is on b Yellow Light Indicates battery is charging c Battery will be fully charged when yellow light goes off Note Charging will take up to 4 hours It is recommended that the battery be charged immediately up on receipt 5 To return the lift to service disconnect power supply remove the power pack from the charger Fit the power pack to the lift and make sure the latch holding the pack in place is fully engaged Click in place The charging of Hoyer electric lifts is simple and straightfor ward but it is important to follow the charging instructions closely Please pay particular attention to the following warnings they will help you avoid problems with discharged batteries 17 294000 10062 Rev A mover English Stature AWARNING KEEP the batteries fully charged Place the battery on charge whenever it is not in use If it is more convenient to do so place on charge every night The charger will not allow the ba
10. care at our discretion Only the Joerns Healthcare Product Service Department can dispatch authorized technicians This warranty is extended to the original purchaser of the equipment 24 294000 10062 Rev A English Weyer Stature 25 294000 10062 Rev A EA Joerns Healthcare Joerns Healthcare Inc 2100 Design Road Suite 100 Arlington TX 76014 USA Tel 800 826 0270 Fax 800 457 8827 www joerns com 2011 Joerns Healthcare 294000 10062 Rev A DCO 11 0339
11. e before use Shoulder Straps Leg Strap Shoulder Strap Attachment Shoulder Strap Attachment Point Leg Straps 4 point positioning cradle Example of 4 point cradle sling with safety clip system 13 294000 10062 Rev A NW Hoyer English Stature Securi3 sling attachment system Example of installation NOTE For detailed fitting instructions please refer to the user guide supplied with each sling WARNING Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage DO NOT use slings that are worn or damaged WARNING HOYER RECOMMENDS THE USE OF GENUINE HOYER PARTS Hoyer slings and lifters are not designed to be interchangeable with other manufacturer s products Using other manufacturer s products on Hoyer products is potentially unsafe and could result in serious injury to patient and or caregiver WARNING Refer to maximum weight capacity of lift Sling capacity is limited by the maximum capacity of the lift 14 294000 10062 Rev A English EES Stature 6 Removal of Spreader Bar Cradle Systems FOLLOW THESE INSTRUCTIONS EXACTLY Your Stature lift has the option of using both a 6 point spreader bar and 4 point positioning cradle The removal of either of these systems is completed easily by the use of a quick release pin This is done quickly and easily but you must read the following safety instructions
12. eight 17 7 inches 1975 mm Spreader Bar Min Height usable 26 6 inches 675 mm Weights Mast Base amp Boom Assembly 142lbs 64 5kgs 4 point positioning cradle 13 2lbs 6kgs Power Pack 6 6 lbs 3 kgs io F lt Mr seen ee een 162lbs 73 5kgs All measurements are within a 5 5 degree of tolerance 22 294000 10062 Rev A English Meyer Stature ELECTRICAL SPECIFICATIONS BATTERIES e ea 12 volt Rechargeable sealed lead acid type BATTERY CAPACITY 2 3 2 Ampere hours CHARGER RATED INPUT eneen 230Vac 50 60Hz CHARGER RATED OUTPUT een 27 4 29 0 VDC 0 8A Electric Shock Protection CHARGER esters een CLASS Il RA INTERNAL POWER SOURCE Degree of Shock Protection CHARGER is naasten deelne et TYPE B BIE Teter teens reren teen TYPE B INTENDED OPERATING ENVIRONMENT gt 5 lt 40 Outside this environment functionality and safety may be compromised MOTOR GEAR BOX ia Planetary Type STRAP teneerste beten Nylon woven 23 294000 10062 Rev A Ki Hoyer English Stature 10 Warranty This warranty covers HoyerPro lifts only Lifts not covered under this warranty include but are not limited to Advance H HML400 HPL600WB HPL600WBSC HPL402 C HLA and variations HoyerPro lifts are guaranteed for a period of two years from the date of delivery against defects in materials and workmanship under normal use and service This warranty includes a
13. g hooks clips on the spreader bar cradle and side suspenders for excessive wear e MAKE sure the legs open and close correctly e OPERATE the hand control to confirm the boom raises and lowers satisfactorily ON electric powered lifts check the operation of the emergency stop button EXAMINE slings for fraying or other damage DO NOT use any sling if damaged or if the sling shows signs of wear CONFIRM the lift is not giving a low battery alarm when the hand control is operated If the alarm sounds DO NOT use and place on charge immediately e CHECK fasteners for tightness and wear MAINTENANCE INSPECTION AND TEST Joerns Healthcare recommend a thorough inspection and test of the Hoyer Stature lift and lifting accessories slings scales etc is carried out on a regular basis Inspection frequency varies depending on locality so you must check with your dealer or local government agency as appropriate regarding how often an inspection is required The examination and test should be conducted according to the recommendations and procedures provided in this manual Joerns Healthcare recommends maintenance inspection and certified testing is carried out by authorized service agent dealers only 19 294000 10062 Rev A Hoyer English Stature THESE CHECKS SHOULD INCLUDE E v Required X Recommended 2 8 S 6 months in North America 3 EE 1 SPREADER BAR Check the spreader bar for freedom of rotation and swing
14. ll mechanical and electrical components Aluminium structural components and mechanical components on lifts are covered under warranty for a period of five 5 years from the date of delivery Damage caused by use in unsuitable environmental conditions or failure to maintain the product in accordance with user and service instructions is not covered Any alteration modification or repair unless performed by or authorized in writing by Joerns Healthcare will void this warranty Parts HoyerPro lifts contain various parts that wear from normal use These parts such as DC batteries and casters are not covered under the two year warranty but are covered for 90 days after date of delivery Joerns Healthcare s obligation under this warranty is limited to supplying replacement parts servicing or replacing at its option any product which is found by Joerns Healthcare to be defective Warranty replacement parts are covered by the terms of this warranty until the product s original warranty period expires When requested by Joerns Healthcare parts must be returned for inspection at the customer s expense Credit will be issued only after inspection Service Most service requests handled by the facility Maintenance Department with assistance from the Joerns Healthcare Product Service Department Most parts requested can be shipped next day air at the customer s expense Should a technician be required one will be provided by Joerns Health
15. ll power to the lift and only be reset by twisting the button anticlockwise and releasing 11 294000 10062 Rev A Ki mover English Stature 5 Electrical Emergency Down Up Emergency lower down and raise up buttons are provided at the front of the control box This is operated by inserting a ballpoint pen into the button highlighted A This will bring the boom up or down should the hand control fail at any time 6 Mechanical Emergency Down In the case of a complete electrical failure the Stature lift is fitted with mechanical lowering device This device is located on the left hand side of the lift s chassis The lowering mechanism is operated by inserting a 6mm Hex socket into the aperture and onto the mechanism turning clockwise to raise the lift and anticlockwise to lower the lift This can be done manually with a socket wrench Recommendation In order to raise or lower the boom more quickly it is recommended that a 6mm Hex socket be used in conjunction with a 1 4 inch drive adaptor and an electric reversible drill NOTE do not use hammer setting This will increase the speed in which the patient can be safely raised and lowered A 6mm Hex socket is contained in the top cap located on the top of the mast NOTE Before raising or lowering the patient ensure you have you have planned your destination carefully For instance back onto a chair or bed 7 Batteries The batteries are protected from deep di
16. ol ep Check for wear on the central pivot Check for firm attachment to the boom 2 BOOM Check the attachment of the boom to the mast carriage vw w Lie Make sure there is only minimal movement 3 MAST Check it is firmly connected to the chassis MOTOR GEARBOX This should require no maintenance other than X checking for correct operation and listening for unusual noise 5 POWER PACK Check the function of the emergency stop button and alef emergency down up 6 BATTERIES The batteries are housed in the power pack and should not require maintenance other than the regular charging as detailed in the Vv charging instructions Check that the connections remain clean Confirm the battery bracket is secure and undamaged 7 LEG ADJUSTMENT Check that the legs operate in both full extensions inward outward 8 CASTORS Check all castors for firm attachment to the legs Check for free rotation of the castor and the wheels 9 CLEANING Wipe down with a clean cloth using soap and water and or any hard surface disinfectant Harsh chemical cleaners or abrasives should be avoided as these may damage the surface finish of the lift Avoid x Iw excessive wetting especially electrical areas and the opening to the base of the hoist We recommend that the cloth is soaked in the solution squeeze out excess fluid and wipe hoist surface 10 LOAD TEST The load test should be carried out in accordance with the manufacturer s test procedures see
17. r and or a local government agency The Hoyer Stature is suitable for the following CATEGORIES of lift within the working param eters of the lifts specified in the TECHNICAL SPECIFICATIONS see contents page Category A Wheelchair Category B Bed Category C Bath dependent upon setting Category D Toilet Shower Chair Category E Floor Category F 90 degree Rotation The Hoyer Stature is suitable for patients in the SITTING SITTING RECUMBENT and RECUMBENT positions The examples of slings suitable for this device are listed as follows e Hoyer Quickfit e Hoyer Access e Hoyer Full Back e Hoyer Comfort e Hoyer Quickfit Deluxe e Hoyer Silkfit e Hoyer Long Seat The CE mark The Hoyer Stature carries the CE mark and complies with the following EC directives e Medical Device Directive 93 42 EEC EMC Directive 89 336 EEC e Low Voltage Directive 73 23 EEC 4 294000 10062 Rev A English ES Stature 3 Assembly and Commissioning Instructions CARTON CONTENTS Place the carton in a clear working area and open carefully The carton contains Hoyer STATURE LIFT WALLET CONTAINING DOCUMENTS HAND CONTROL BATTERY PACK DESK TOP CHARGER STAND LEAD FASTENER KIT INCLUDES SCREWS ALLEN KEY HEX SOCKET CAPPING PLATE AWARNING The Hoyer Stature is heavy and will need to be lifted with care You may need assistance to lift the Hoyer Stature from the carton ASSEMBLY INSTRUCTIONS Remo
18. scharge by a LOW VOLTAGE ALARM This will sound when the batteries need recharging and the hand control is being operated It will not sound independently of the hand control being operated DO NOT IGNORE THIS WARNING ALARM Complete the lifting operation and place the battery on charge see charging instructions 12 294000 10062 Rev A English ES Stature 8 Slings The Hoyer Stature has the option of both a 6 point spreader bar and a 4 point positioning cradle Both systems use different attachment methods and slings The 6 point system uses slings with webbing loops which allow positioning adjustment by selecting different coloured loops The 4 point cradle uses the Secruri3 safety clip system and adjustment is made by rotating the 4 point cradle either upward or down Loop strap slings Hoyer Quickfit Full Back Quickfit Deluxe Long Seat Access and Silkfit Safety clip slings Hoyer Comfort The 6 point system attaches to the spreader bar hooks via loop straps shown below each sling is supplied with instructions Please study the instruction guide before use Leg Strap Shoulder Straps Attachment Points Shoulder Strap I Attachment Points Leg Straps da Ss 6 Point spreader bar Example of 6 point spreader bar sling with loop attachments The four point cradle sling attaches to the cradle studs via a safety clip system shown below each sling is supplied with instructions Please study the instruction quid
19. t to do so e YOUR lift is for patient lifting DO NOT use it or allow it to be used for any other purpose e DO NOT bump the lift down steps loaded or unloaded DO NOT attempt to negotiate a loaded lift on a slope which exceeds 1 12 approximately 5 degrees e DO NOT attempt to negotiate a slope without a second helper being present e DO NOT use in a wet or corrosive environment such as poolside locations e DO NOT use on extra thick pile carpet when the lift is fully loaded e NEVER operate lift with loose worn or missing parts fasteners e Joerns Healthcare recommends that slings be checked regularly and particularly before use for signs of fraying or damage DO NOT use slings that are worn or damaged e HOYER RECOMMENDS THE USE OF GENUINE HOYER PARTS Hoyer slings and lifters are not designed to be interchangeable with other manufacturer s products Using other manufacturer s products on Hoyer products is potentially unsafe and could result in serious injury to patient and or caregiver e Refer to maximum weight capacity of lift Sling capacity is limited by the maximum capacity of the lift 10 294000 10062 Rev A English ES Stature 5 Operating Instructions OPERATING CONTROLS Emergency Detachable Stop SC Battery Pack Emergency CD Lower Raise Hand Eege Battery Indicator Ic 1 Leg adjustment The legs on the Hoyer Stature are electrically adjustable for width The legs can be
20. tteries to overcharge A WARNING NEVER run the batteries completely flat As soon as the audible warning sounds complete the lifting operation in hand and place on charge A CAUTION NEVER store the power pack for long periods without regular charging throughout the storage period A WARNING ALWAYS make sure the mains power to the charger is switched off before connecting or disconnecting the power pack AWARNING NEVER leave the power pack plugged in to the charger with the mains power off AWARNING Do not charge an electric lift in a bathroom or shower room 18 294000 10062 Rev A English ES Stature 8 Maintenance Schedule amp Daily Check List All Hoyer products are designed for minimum maintenance however some safety checks and procedures are required A schedule of DAILY tasks is detailed below Daily checks and a six monthly service inspection and test will ensure a lift is kept in optimum safe working condition A list of spare parts is available upon request The LOAD TEST and certification should only be carried out by qualified personnel or an authorized service agent dealer DAILY CHECK LIST Joerns Healthcare strongly recommends the following checks be carried out on a daily basis and before using lift e MAKE sure the lift moves freely on its castors e MAKE sure the spreader bar is free to rotate and swing e EXAMINE the spreader bar cradle is firmly attached to the boom e EXAMINE the slin
21. ve all the parts from the carton and place on the floor taking care to protect the finish from damage 1 Place the chassis and mast which are connected in a clear space The mast and chassis should be rested on the push handle which will ensure the product remains stable while connecting the legs and boom to the product 5 294000 10062 Rev A H r IE English Stature 2 Fit the legs to the chassis using two 6mm countersunk screws per leg as provided NOTE There is a left and a right leg and they are configured as shown below 3 Using Allen Key provided tighten the 6mm screws located on each side of the chassis A WARNING The screws should be secured firmly 4 Insert the curved boom section into the boom carriage Secure the assembly by inserting the two 6mm countersunk screws into the blue capping plate provided in the fastener kit as shown below and tighten firmly 6 294000 10062 Rev A English ES Stature 5 Attach four point positioning cradle to the lift boom by inserting the split pin Ensure pin is secure 6 Stand the Stature upright and apply the brakes A WARNING Be careful when lifting the Stature to the upright position as it is heavy Fit hand control plug into the bottom of the control box located on the mast ensure correct alignment to the plug socket Fit power pack to the lift and make sure the latch holding the pack in place is fully