1. FAGOR BOTTLE COOLER EQUIPMENT Manual for installation use and maintenance FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 TABLE OF CONTENTS 1 RECEIVING AND INSPECTING THE EQUIPMENT 3 2 SPECIFICATIONS 4 3 INSTALLATION 5 3 1 UNCRATING 5 3 2 SEALING 5 3 3 CLEANING OF CABINET 5 3 4 LOCATION 5 3 5 DATA PLATE 6 3 6 ELECTRICAL CONNECTIONS 6 3 7 DIVIDER INSTALLATION 7 4 OPERATION 7 4 1 DEFROST 7 4 2 TROUBLESHOOTING 7 5 MAINTENANCE 8 6 WIRING DIAGRAMS 10 7 WARRANTY 11 8 TECHNICAL INFORMATION 13 Page 2 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 1 RECEIVING AND INSPECTING THE EQUIPMENT Upon receiving your new FAGOR BAR EQUIPMENT check the package and the machine for any damages that may have occurred during transportation Visually inspect the exterior of the package if damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retain all crating material until inspection has been made Contact the dealer through which you purchased the unit Check the compressor compartment housin
2. a Check the thermostat is not in OFF position b Check the thermostat is at position 5 or higher c Check the unit is not on defrost cycle d Check gasket is in good condition and door is sealed e Check fan is moving Open the door press and hold door switch for verification f Don t put any food inside until unit is at temperature g Be sure castors or legs were installed 3 There is water under the refrigerator a Check the drain pipe is over the pan b Check cabinet is level Page 7 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 5 MAINTENANCE Stainless Steel Care and Cleaning Proper cleaning of stainless steel requires soft cloths or plastic souring pads Never use steel pads wire brushes or scrapers Cleaning solutions need to be alkaline or non chloride cleaners Any cleaner containing chlorides will damage the protective film of the stainless steel Chlorides are also commonly found in hard water salts and household and industrial cleaners If cleaner containing chlorides are used be sure to rinse repeatedly and dry thoroughly upon completion Routine cleaning of stainless steel can be done with soap and water Extreme stains or grease should be cleaned with a non abrasive cleaner and plastic scrub pad There are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Never use an
3. of the User s records pertaining to the Equipment to determine whether a defect exists whether the conditions set forth in this Warranty have been satisfied and whether or not the applicable Warranty is in effect THE FOREGOING WARRANTY IS IN LIEU OF AND EXCLUDES ALL OTHER WARRANTIES NOT EXPRESSLY SET FORTH HEREIN WHETHER EXPRESS OR IMPLIED BY OPERATION OF LAW OR OTHERWISE INCLUDING BUT NOT LIMITED TO ANY REPRESENTATION OF PERFORMANCE AND ANY IMPLED WARRANTIES OF TITLE NON INFRINGEMENT MERCHANTABILITY OR FITNESS FOR A PARTICLULAR PURPOSE NO OTHER WARRANTIES ARE AUTHORIZED ON BEHALF OF FAGOR UNLESS SPECIFICALLY ISSUED BY FAGOR Fagor shall have no liability for incidental or consequential losses damages including without limitation or expenses loss of sales spoiled food profits or goodwill claims whether or not on account of refrigeration failure or punitive or exemplary damages directly or indirectly arising from the sale handling or use of the Equipment or from any other cause relating thereto whether arising in contract tort warranty strict liability or otherwise Fagor s liability hereunder in any case is expressly limited at Fagor s election to repair or replacement of Equipment or parts therefore or to the repayment of or crediting the user with an amount equal to the purchase price of such goods Prices amp Specifications Fagor reserves the right to change the prices and specifications of the equipment and or material
4. 8 AWG o E C Lampara Light JB Ara a de Conexi nes Juction Box Controlador El ctronico Electronic Controller TA Termostato M canico Thermostat T Azul Obscuro Dark Blue y Tl Sensor de Ambiente Environment Sensor Amarillo Y ellow G T2 Sensor Deshiclo Defrost Sensor Rojo Red I8AWG H INTL Interruptor Lampara Ligth Switch es reso 1 L N es awa Note Some models doesn t include the lamp installed from factory check your sales representative Nota Algunos modelos no incluyen la l mapra instalada de fabrica revise con su representate de ventas Page 10 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 WARRANTY Limited Warranty One Year Parts amp Labor Warranty Fagor Commercial Inc Fagor Warrants to the fist end user purchaser the User that the Fagor brand equipment sold hereunder except for parts and accessories which carry the warranty of a supplier the Equipment will be free from defects in material and factory workmanship under normal conditions of use and maintenance for a period of one 1 years from the date of installation Warranty commencement date but in no event to exceed eighteen 18 months from the date of shipment from the factory Warranty is Not Transferable Warranty Coverage If there is a defect in material or factory workmanship covered by this Warranty reported to Fagor during the perio
5. ATA PLATE SERIAL NUMBER FOR THE EQUIPMENT 8 digits and ends in M The data plate in located inside the unit near the top front left corner Under no circumstances should the data plate be removed from the unit The data plate is essential to identify the particular features of your unit and is of great benefit to installers operators and maintenance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation 3 6 ELECTRICAL CONNECTIONS Refer to the amperage data in this manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information HEAVY APPLIANCES A protected circuit of the correct voltage and amperage must be run for connection of the supply cord Unit must be grounded and connected in accordance with NEC Article 422 Appliances DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine still running when power is off disconnect power at the circuit breaker before unplugging the machine Page 6 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 WARNING Machine and compressor warranties are void if failure is d
6. TING Cut and remove the outer packaging Cut the 4 clamps that hold the refrigerator to the skid Lift the unit off the skid If machine was laid down during this operation leave the cabinet upright for 24 hours before plugging into power source 3 2 SEALING WHEN SANITATION CODES REQUIRE SEALING TO FLOOR THIS METHOD MAY BE USED 1 Tip cabinet and apply a bead of silicone seal on bottom edge of the base 2 Return cabinet to upright position and using proper equipment lift cabinet into location Heavy appliances should not be used on the same circuit with the cooler CAUTION If an extension cord is necessary use only a three wire grounding type of wire size 16 AWG or heavier do not exceed 20 feet in length The use of ungrounded cords or overloaded circuit voids compressor warranty 3 3 CLEANING OF CABINET The exterior of the cabinet is painted and should be cleaned only with lukewarm water taking care not to scratch the paint Mild detergents are also recommended The interior can be cleaned in a similar manner THE CONDENSER MUST BE CLEANED AT REGULAR INTERVALS FAILURE TO DO SO CAN CAUSE COMPRESSOR MALFUNCTION AND WILL VOID WARRANTY Clean approximately every six months depending upon usage dust etc Pull cabinet away from wall and thoroughly vacuum the condenser and surrounding surfaces This cooler is designed to maintain your beer temperature within the most desirable range You can expect this temperature with the proper tem
7. ations amp Returns Cancelled orders and returned merchandise are subject to a 25 restocking and handling charge Written authorization is required for a return of any equipment All equipment returned must be in its original factory crate freight prepaid and must be in the same condition as originally shipped by Fagor Returns will only be authorized within 30 days of invoice date Warranty Register your product with Fagor Commercial to validate you warranty Service calls must be made directly through Fagor service department 1 866 463 2467 or e mail servicerequest Fagorcommercial com You may register your product online at http www Fagorcommercial com Page 12 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 5 2 TECHINICAL INFORMATION If further technical information is needed please contact the Service Department directly Toll Free 866 463 2467 Phone 305 7790170 FAGOR 13105 NW 47th Ave Miami Fl 33054 Phone 305 779 0170 www fagorcommercial com Page 13 For Customer Service Call 1 866 GO FAGOR
8. d acid based cleaning solution Many food products have an acidic content which can deteriorate the finish Be sure to clean the ALL food products from any stainless steel surface Common items include peppers tomatoes and other vegetables Cleaning the Condenser Coil DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit Disconnect machine Remove front bottom panel and carefully slide out the condensing unit The condenser coil requires regular cleaning recommended every 30 60 days depending of the accumulation of dust and grease If the buildup on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush Heavier dust build up may require a vacuum or even compressed air to blow though the condenser coil If heavy grease is present there are de greasing agents available for refrigeration use and specifically for the condenser coils The condenser coil may require a spray with the de greasing agent and then blown through with compressed air Be sure all electrical and mechanical parts are dry before turning on the power Never use a high pressure water wash for this cleaning procedure as water can damage the electrical components located near or at the condenser coil Do not place filter material in front of condenser coil This material blocks air flow to the coil similar to having a dirty coil If you keep
9. d the applicable Warranty is in force and effect Fagor will repair or replace at Fagor s option that part ground shipping only of the Equipment that has become defective and will cover labor cost straight time only within the corresponding warranty period of time Fagor shall bear all labor costs straight time only in connection with the installation of these replacement parts provided that the installation is conducted by Fagor or its authorized representative Charges for warranty travel time round trip total two 2 hours or up to 100 miles total Any charges exceeding those stated herein must have prior authorization by Fagor Travel outside of the two 2 hours or 100 miles and any work performed at overtime or weekend rates would be the responsibility of the owner user In the case Fagor deems the equipment non repairable said equipment will be replaced and the replacement unit s will carry the same warranty period from the original unit s installation date original Warranty Commencement Date Additional Three Year Compressor Part Warranty In addition to the warranty set above Fagor warrants the sealed compressor part only for an additional four 4 years based on the installation date This warranty is for defects both in workmanship and material under the normal and proper use and maintenance service The four 4 year extended warranty only applies to sealed parts of the compressor and does not apply to any other part or compo
10. g and visually inspect the refrigeration package Be sure lines are secure and base is still intact A NOTE FROM OUR QUALITY CONTROL MANAGER CONGRATULATIONS ON YOUR NEW PURCHASE WE WOULD LIKE TO WELCOME YOU TO THE FAGOR TEAM THE UNIT IN FRONT OF YOU IS A GREAT PIECE OF EQUIPMENT THAT WILL BECOME ONE OF YOUR MOST RELAIBLE TOOLS IN YOUR DAILY OPERATIONS FOR YEARS TO COME PRIOR TO SHIPPING YOUR UNIT OUR TRAINED SERVICE TECHNICIANS TESTED YOUR UNIT FOR A PERIOD OF 12 HOURS THIS PERFORMANCE TEST WAS RECORDED AND A COPY OF THE RESULTS IS INCLUDED WITH THIS SERVICE MANUAL DURING THIS TEST OUR HIGHLY QUALIFIED PERSONNEL INSPECTED YOUR MACHINE FOR LEAKS LOSE COMPONENTS AND IMPROPER NOISE LEVELS WE ALSO TESTED THE COOLING PERFORMANCE IN AN EFFORT TO GIVE YOU THE BEST AND MOST RELAIBLE UNIT POSSIBLE Page 3 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 2 SPECIFICATIONS Refrigerant Charge oz R134A Crated 12 oz Weight Bottles LBS AMBIENT TEMPERATURE The above equipment mentioned are tested in the ambient temperature between 60 F to 90 F If the equipment is installed in an ambient higher than 90 F it will reduce the equipment efficiency and consume more energy Page 4 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 3 INSTALLATION 3 1 UNCRA
11. nent including but not limited to cabinet temperature control refrigerant motor starting equipment fan assembly or any other electrical or mechanical component Exclusions from and Conditions to Warranty Coverage This Warranty does not cover parts or accessories which a carry the warranty of a supplier or b are abused Application of this Warranty is further conditioned upon the following Installation The Equipment must be properly installed in accordance with Fagor s installation procedures and by a professional technician No Alteration The Equipment must not have been modified or altered from its condition at the date of original installation Use FAGOR EQUIPMENT IS NOT DESIGNED FOR PERSONAL FAMILY OR HOUSEHOLD PURPOSES AND ITS SALE FOR SUCH PURPOSES IS NOT INTENDED IN THE EVENT THE EQUIPMENT IS SO USED THIS WARRANTY SHALL BE NULL AND VOID AND THE EQUIPMENT SHALL BE DEEMED TO HAVE BEEN SOLD AS IS WHERE IS WITHOUT ANY WARRANTY OF ANY KIND INCLUDING WITHOUT LIMITATION ANY WARRANTY OF TITLE NON INFRINGEMENT MERCHANT ABILITY OR FITNESS FOR A PARTICULAR PURPOSE Proper Maintenance and Operation The Equipment must be properly maintained and operated in accordance with Fagor s maintenance and operating procedures All service labor and parts must be acquired from Fagor or its authorized service representative for the User s area This warranty is void if failure is a direct result of handling and or transportation fi
12. perature control setting and in a normal environment It is important to understand that when the beer is purchased it must be placed inside the cooler as soon as possible to avoid excessive warm up If this happens it may take many hours for the temperature to be reduced to the desirable range No provision is made for rapid cooling of beer which has become too warm 3 4 LOCATION Units represented in this manual are intended for indoor use only Be sure the location chosen has a floor strong enough to support the total weight of the unit and contents For the most efficient operation be sure to provide good air circulation inside and outside of the unit Page 5 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 Inside cabinet The first cleaning must be made when you unpack the unit and before switching it on Clean it with water and a mild detergent When it is clean and dry insert the accessories in the appropriate places for the best use of the user Outside cabinet Be sure the unit has good air circulation around it Avoid hot corners and locations near stoves and ovens It is recommended the unit be installed no closer than 2 from any wall The place where the refrigerator is placed must be open and clean avoiding that de fan of the condensing unit absorbs materials which are deposited then into the condenser blades and coil which can produce failures 3 5 D
13. r coil and evaporates it at an external condensate evaporator pan Each drain can become loose or disconnected from moving or bumping the drain IF YOU NOTICE EXCESSIVE WATER ACCUMULATION ON THE INSIDE OF THE UNIT be sure the drain tube is connected from the evaporator housing to the condensate evaporator drain pan IF WATER IS COLLECTED UNDERNEATH THE UNIT you may want to check the condensate evaporator drain tube to be sure it is still located inside the drain pan The leveling of the unit is important as the units are designed to drain properly when on a level surface if your floor is not level this can also cause drain problems Be sure all drain lines are free of obstructions typically food product is found blocking drain lines causing water to back up and overflow the drain pans Page 9 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 WIRING DIAGRAMS Color Estandar Standard Calibre AWG Ref Color AWG Size S mbolo TET E S mbolo a eas Symbol Descripci n Description Symbol Descripci n Description VE Ventilador de Evaporador Evaporator s Fan RDE Resistencia de Descarche Defrost Resistance Compresor Compressor RG Resistencia de Desague Drain Resistance Verde Green 18 AWG V Ventilador de Condensador Condenser Fan CONT Contactor Auxiliar Contactor C Azul Obscuro Dark Blue 16 AWG Marr n Brown 16 AWG Azul Claro Light Blue 18 AWG Marr n Brown 1
14. re water accident misuse acts of god s attempted repair by unauthorized persons improper installation if serial number has been removed or altered or if unit is used for purpose other than it was originally intended Failure to comply with any of these conditions will void this Warranty In addition this Warranty does not cover defects due to apparent abuse misuse or accident Page 11 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 Parts Warranty Coverage Fagor warrants all new machine parts produced or authorized by Fagor to be free from defects in material and workmanship for a period of 90 days from the Warranty Commencement Date If any defect in material and workmanship is found to exist within the warranty period Fagor will replace the defective part without charge Defective parts become the property of Fagor Fagor will have no responsibility to honor claims received after the date the applicable Warranty expires Notwithstanding the foregoing any claim with reference to the Equipment or any parts therefore for any cause shall be deemed waived unless submitted by the User to Fagor within 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the right at its own expense to have its representatives inspect the Equipment at the User s premises and to request all
15. the Condenser clean you will minimize your service expense and lower your electrical costs Failure to maintain a clean condenser coil can initially cause high temperatures and excessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Page 8 For Customer Service Call 1 866 GO FAGOR FAGOR BAR EQUIPMENT Operations and Service Manual rev April 2013 Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY associated with the compressor or cost to replace the compressor To put back the condensing unit in its place slide in the unit carefully BE SURE DRAIN PIPE IS LOCATED OVER THE PAN Replace front bottom panel Gasket Maintenance Gaskets require regular cleaning to prevent mold and mildew build up and also to keep the elasticity of the gasket Gasket cleaning can be done with the use of warm soapy water Avoid full strength cleaning products on gaskets as this can cause them to become brittle and prevent proper seals Also never use sharp tools or knives to scrape or clean the gasket which could possibly tear the gasket and rip the bellows Gaskets can easily be replaced and do not require the use of tools or authorized service persons The gaskets can be pulled out of the grove in the door and new gaskets can be pressed back into place Drain Maintenance Each unit has a drain located inside the unit which removes the condensation from the evaporato
16. ue to improper electrical installation 3 8 DIVIDER INSTALLATION 1 Hook the dividers to their proper place so you have division within your cabinet 4 OPERATION Verify thermostat is in the OFF position prior to connecting the unit to its power source Failure to do so could lead to electrical failures Keep in mind the evaporator fans and lights will still have power while the thermostat in the OFF position Connect unit to power supply Temperature controller inside the cabinet goes from O OFF Position to 7 Coolest Position Set control at position 5 for temperature average of 35 F 4 1 DEFROST The unit will not require defrosting if the door is only opened for a minimum time Defrosting should be done when the box is empty and periodically To do this unplug the unit and leave the door open for fifteen minutes Defrost water will accumulate in a pan under the evaporator and will drain to a plastic container in the storage area under the unit Do not use a pick knife etc to pry ice from evaporator as this could puncture evaporator or damage the finish 4 2 TROUBLESHOOTING Sometimes working failures are due to simple causes which can be solved by the user Before asking for the help of a qualified technician you have to do some verification These failures are not covered by the warranty 1 Refrigeration doesn t work a Check the unit is still connected to power supply 2 Refrigerator doesn t reach temperature
17. without notice Prices are FOB Fagor warehouses All orders are subject to acceptance by Fagor Commercial Inc Terms All orders are subject to credit approval All Invoices not paid within the specified terms will be subject to a 1 5 per month delinquency charge Buyer agrees to pay all costs of collection including such attorney s fees as may be allowed by law Taxes This price list does not include any Federal State City or Local taxes which may apply and are subject thereto Shipment Requested carrier will be used upon request Fagor has the right to ship via any responsible carrier if requested carrier is unavailable Shipping charges are payable by consignee and any claims arising as such charges shall be resolved between the carrier and the consignee Shipping dates are approximates Fagor is not responsible for any delays in deliveries that are beyond our control Damaged Merchandise Inspect shipment for any damage before accepting it If damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipts Fagor assumes nor responsibility for damages while in transit Concealed Damage If there is concealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retain all crating material until inspection has been made Cancell