Home
vtp series - tapas display
Contents
1. H 0 71 al For Customer Service Call 1 866 GO FAGOR www fagorcommercial com 11 VTP SERIES OPERATIONS AND SERVICE MANUAL 8 PARTS BREAK DOWN V1 VITRINA REFRIGERADA TAPAS COD PIEZA SUSTITUYE A Acabado SUSTITUIDO POR ASE sw Monero Jua monero monero eee we av pp 1111 ca a FAGOR ean 2005 som 2020 mca o 00m s020 2050 ots O Escala C digo maquina RECAMBIOS VTP 175 CA For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 12 VTP SERIES OPERATIONS AND SERVICE MANUAL COD PEZA COTAS SIN TOLERANCIA DIN 7168 7 SUSTITUYE A me CT a em PA E 94190 m quina RECAMBIOS VTP 139 CA For Customer Service Call 1 866 GO FAGOR www fagorcommercial com 13 Denominacion 6041090003 CONTAINER GN 1 3 40 V107130062 FRAME VTP139 A 1366mm 6007130108 FRAME PLAT 5540mm 603902M0002 ACRILICO PANEL 44X1820X1 V109050057 PANEL CURVED VTP 167170004 GLASSES RAIL VTP 139 C 107130058 TOP PANEL 139 1366 6035050006 GLASS DOOR 550 165 3 VTP 139 6021010010 COMPRESSOR TL 4
2. compressor and does not apply to any other part or component including but not limited to cabinet temperature control refrigerant motor starting equipment fan assembly or any other electrical or mechanical component The original purchaser shall be responsible for returning the defective compressor to Fagor prepaid This warranty shall be void if the compressor in Fagor s sole judgement has been subjected to misuse neglect alteration or accident operated contrary to the recommendations specified by the Unit manufacturer repaired or altered by anyone other than Fagor in any way so as in Fagor s sole judgement to affect its quality or efficiency or if the serial number has been altered defaced or removed This warranty does not apply to a compressor in any unit that has been moved from the location where it was originally installed Parts Warranty Coverage Fagor warrants all new machine parts produced or authorized by Fagor to be free from defects in material and workmanship for a period of 90 days from the Warranty Commencement Date If any defect in material and workmanship is found to exist within the warranty period Fagor will replace the defective part without charge Defective parts become the property of Fagor Fagor will have no responsibility to honor claims received after the date the applicable Warranty expires Notwithstanding the foregoing any claim with reference to the Equipment or any parts therefore for any cause shal
3. FAGOR VTP SERIES TAPAS DISPLAY Manual for installation use and maintenance VTP SERIES OPERATIONS AND SERVICE MANUAL TABLE OF CONTENTS 0 TABLE OF CONTENTS 1 RECEIVING AND INSPECTING THE EQUIPMENT N SPECIFICATIONS 2 1 DIMENSIONS 3 INSTALLATION 3 1 UNCRATING 3 2 LOCATION 3 3 DATA PLATE 3 4 LEVELING 3 5 ELECTRICAL CONNECTIONS OPERATION ui 0 U A U N MAINTENANCE TROUBLE SHOOTING WIRING DIAGRAMS e e N e PARTS BREAKDOWNS 0 N WARRANTY For Customer Service Call 1 866 GO FAGOR www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL 1 RECEIVING AND INSPECTING THE EQUIPMENT Upon receiving your new Fagor VTP check the package and the machine for any damages that may have occurred during transportation Visually inspect the exterior of the package If damaged open and inspect the contents with the carrier Any damage should be noted and reported on the delivering carrier s receipt In the event that the exterior is not damaged yet upon opening there is concealed damage to the equipment notify the carrier immediately Notification should be made verbally as well as in written form Request an inspection by the shipping company of the damaged equipment Retain all crating material until inspection has been made Contact the dealer through which you purchased the unit For Customer Service Call 1 866 GO FAGOR www fag
4. G R134A 220V 602101M0018 COMPRESSOR NE 6160 Z 115 V 6029020023 CONDENSER 7x3 VTP 6021050008 FAN MOTOR 220V 120X120 C BOLAS 6021050020 FAN MOTOR 115V 120X120 C BOLAS 1 1 604701M0002 DRYER 25 gr 1 1 1 1 6007020003 CAPILARY TUBE 0 42 mm 3000mm 3000mm 3000mm 3000mm 602129M0005 FLUORESCENT LIGHT 30 32W 602129M0010 BALLAST ELECTRONIC 120 220 V V109170057 SOP REACT Y CEBADOR VTP INC 109010033 FRONT PANEL VTP 602135M0024 THERMOSTAT CAREL 120V 6021130003 ORANGE LIGHT 6021130001 ON OFF SWITCH 6021130002 LIGHT SWITCH 6035010003 GLASS CURVED 1364MM RED GREY 602101M0057 STARTING KIT TL 4 G 6003010170 SIDE PANNEL 6003010012 LEG M 10x40 PR 30 V139020002 PROTECTOR LIGHT VTP 139 6007130108 DOORS RAIL 5540mm 107130018 GLASS JOINT VTP 1366PLAT 6007130114 PERF PANT SILVER 5540mmVTP139 107010001 PROBE HOUSING VTP SERIES OPERATIONS AND SERVICE MANUAL 9 WARRANTY One Year Parts amp Labor Warranty Fagor Commercial Inc Fagor warrants to the first end user purchaser the User that the Fagor brand equipment sold hereunder except for parts and accessories which carry the warranty of a supplier the Equipment will be free from defe
5. cts in material and factory workmanship under normal conditions of use and maintenance for a period of 1 one year from the date of Installation Warranty Commencement date but in no event to exceed 15 fifteen months from the date of shipment Warranty is Not Transferable Warranty Coverage If there is a defect in material or factory workmanship covered by this Warranty reported to Fagor during the period the applicable Warranty is in force and effect Fagor will repair or replace at Fagor s option that part of the Equipment that has become defective Fagor will cover labor cost within one year from the Warranty Commencement date or 15 months from shipment date whichever occurs first Fagor shall bear all labor costs in connection with the installation of these replacement parts provided that the installation is conducted by Fagor or its authorized representative Charges for warranty travel time to round trip total of 2 two hours or up to 100 miles total Any charges exceeding those stated herein or overtime rates must have prior authorization by Fagor Additional Four Year Compressor Part Warranty In addition to the warranty set above Fagor warrants the compressor part only for an additional four 4 years based on the installation date This warranty is for defects both in workmanship and material under the normal and proper use and maintenance service The four 4 year extended warranty only applies to hermetically sealed parts of the
6. f the cabinet are positioned in the pan Free plug and cord do not plug in yet and place the unit close enough to the electrical supply so extension cords are never used 3 5 ELECTRICAL CONNECTIONS Refer to the amperage data on this manual or on data plate and your local code or the National Electrical Code to be sure unit is connected to the proper power source Verify correct incoming voltage according to the Data Plate information A protected circuit of the correct voltage and amperage must be run for connection of the supply cord Machine must be grounded and connected in accordance with NEC Article 422 Appliances DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit If machine still running when power is off disconnect power at the circuit breaker before unplugging the machine WARNING Machine and compressor warranties are void if failure is due to improper electrical installation For Customer Service Call 1 866 GO FAGOR www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL 4 OPERATION The minimum temperatures in order that foods don t begin to spoil are Refrigeration S02F 10 C 00 Machine must reach proper temperature before loading products If an interruption in the power supply occurs and it is longer than 20 minutes check that the foods don t exceed the critical points check that they a
7. goodwill claims whether or not on account of refrigeration failure or punitive or exemplary damages directly or indirectly arising from the sale handling or use of the Equipment or from any other cause relating thereto whether arising in contract tort warranty strict liability or otherwise Fagor s liability hereunder in any case is expressly limited at Fagor s election to repair or replacement of Equipment or parts therefore or to the repayment of or crediting the user with an amount equal to the purchase price of such goods For Customer Service Call 1 866 GO FAGOR www fagorcommercial com 16 Fagor Commercial Inc 13105 NW 47th Ave Miami Fl 33054 4525 Tel 305 779 0170 Fax 305 779 0173 1 866 GO FAGOR www fagorcommercial com
8. hen it is clean and dry insert the accessories in the appropriate places for the best use of the user Outside cabinet Be sure that the unit has access to ample air Avoid hot corners and locations near stoves and ovens It is recommended that the unit be installed no closer than 2 from any wall The place where the refrigerator is placed must be open and clean avoiding that the fan of the condensing unit absorbs materials which are deposited then into the condenser blades and coil which can produce failures 3 3 DATA PLATE The data plate is located inside the cabinet on the left side panel Under no circumstances should the data plate be removed from the unit The data plate is essential to identify the particular features of your machine and is of great benefit to installers operators and maintenance personnel It is recommended that in the event the data plate is removed you copy down the essential information in this manual for reference before installation For Customer Service Call 1 866 GO FAGOR www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL CAUTION NEVER LAY MACHINE ON ITS SIDE IF NEEDED LEAVE THE CABINET ON ITS NORMAL POSITION FOR 24 HOURS BEFORE PLUGGING INTO POWER SOURCE FAILURE TO MEET THIS REQUIREMENT CAN CAUSE COMPRESSOR FAILURE AND UNIT DAMAGE THAT WILL NOT BE COVERED UNDER WARRANTY 3 4 LEVELING Set unit in its final location Ensure the drain hose or hoses bottom rear side o
9. l be deemed waived unless submitted by the User to Fagor within thirty 30 days after the date the User discovered or should have discovered the claim In connection with all claims under this Warranty Fagor will have the right at its own expense to have its representatives inspect the Equipment at the User s premises and to request all of User s records pertaining to the Equipment to For Customer Service Call 1 866 GO FAGOR www fagorcommercial com P 15 VTP SERIES OPERATIONS AND SERVICE MANUAL determine whether a defect exists whether the conditions set forth in this Warranty have been satisfied and whether or not the applicable Warranty is in effect Exclusions from and Conditions to Warranty Coverage This Warranty does not cover parts or accessories which a carry the warranty of a supplier or b are abused Application of this Warranty is further conditioned upon the following Installation The Equipment must be properly installed in accordance with Fagor s installation procedures e No Alteration The Equipment must not have been modified or altered from its condition at the date of original installation e Use Fagor equipment in not designed for personal family or household purposes and its sale for such purposes is not intended in the event the equipment is so used this warranty shall be null and void and the equipment shall be deemed to have been sold as is where is without any warranty of any ki
10. me verification These failures are not covered by the warranty 1 Refrigerator doesn t work a Check out that machine is still connected 2 Refrigerator doesn t reach temperature a Check out that the thermostat is not in OFF position b Ensure Equipment is in a ventilated place and removed min 2 from any other appliance or heat source The environment maximum temperature must be 38 100 2F d Allthe pans must remain in place for proper operation of the unit e To insure proper air flow product must not be placed higher than the maximum level mark located on the internal wall of the unit f Check out temperature is not Celsius g Don t put any food inside up to VTP is at temperature 3 There is water inside the refrigerator a Check out that drain pan inside the cabinet is in position b Check out that there is not food clogging the drain line 4 There is water under the refrigerator a Check out that the drain pipe is over the pan b Check out cabinet is level Warning To assure proper operation of equipment it is recommended that the unit is on for 8 hours prior to the introduction of perishables For Customer Service Call 1 866 GO FAGOR www fagorcommercial com 10 VTP SERIES OPERATIONS AND SERVICE MANUAL 7 WIRING DIAGRAMS EFT SS ekaa ara 2 mp Foco pluto Filot lame inter TP 13 110 220 VOLT pa
11. nd including without limitation any warranty of title non infringement merchant ability or fitness for a particular purpose e Proper Maintenance and Operation The Equipment must be properly maintained operated in accordance with Fagor s maintenance and operating procedures All service labor and parts must be acquired from Fagor or its authorized service representative for the User s area e This warranty is void if failure is a direct result of handling amp or transportation fire water accident misuse acts of god attempted repair by unauthorized persons improper installation if serial number has been removed or altered or if unit is used for purpose other than it was originally intended Failure to comply with any of these conditions will void this Warranty In addition this Warranty does not cover defects due to apparent abuse misuse or accident The foregoing warranty is in lieu of and excludes all other warranties not expressly set forth herein whether express or implied by operation of law or otherwise including but not limited to any representation of performance and any implied warranties of title non infringement merchantability or fitness for a particular purpose No other warranties are authorized on behalf of Fagor unless specifically issued by Fagor Fagor shall have no liability for incidental or consequential losses damages including without limitation or expenses loss of sales spoiled food profits or
12. orcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL 2 SPECIFICATIONS VTP SERIES TAPAS DISPLAY MODEL rans Amps HP Voltage uE Onz Ref Ship Weight VTP 139 6 3 5 Y 115 60 1 5 15P 8 134a 112 VTP 175 8 3 5 Y 115 60 1 5 15P 8 134a 135 2 1 DIMENSIONS 1 9 1385mm For Customer Service Call 1 866 GO www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL INSTALLATION 3 1 UNCRATING Cut and remove the outer packaging If machine was upright during this operation remember to leave the cabinet laid down for 24 hours before plugging into power source 3 2 LOCATION Units represented in this manual are intended for indoor use only Be sure the location chosen has a floor table cabinet strong enough to support the total weight of the unit and contents For the most efficient operation be sure to provide good air circulation inside and outside of the unit Inside cabinet The first cleaning must be made when you unpack the machine and before switching it on You have to clean it with water and with mild detergent W
13. re not altered and avoid opening the doors NOTE Good air flow inside the cabinet is critical Do not block air flow to the fans and allow space along the front back and sides CAUTION Do no introduce hot foods chemical or corrosive products drugs neither open beverage bottles For Customer Service Call 1 866 GO FAGOR www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL 5 MAINTENANCE Stainless Steel Care and Cleaning Proper cleaning of stainless steel requires soft cloths or plastic souring pads Never use steel pads wire brushes or scrapers Cleaning solutions need to be alkaline or non chloride cleaners Any cleaner containing chlorides will damage the protective film of the stainless steel Chlorides are also commonly found in hard water salts and household and industrial cleaners If cleaner containing chlorides are used be sure to rinse repeatedly and dry thoroughly upon completion Routine cleaning of stainless steel can be done with soap and water Extreme stains or grease should be cleaned with a non abrasive cleaner and plastic scrub pad There are also stainless steel cleaners available which can restore and preserve the finish of the steels protective layer Never use and acid based cleaning solution Many food products have an acidic content which can deteriorate the finish Be sure to clean the ALL food products from any stainless steel surface Common items include peppers tomatoes and other vege
14. tables Cleaning the Condenser Coil DANGER Power must be turned off and disconnected from the power source whenever performing maintenance repair or cleaning the condensing unit Disconnect machine The condenser coil requires regular cleaning recommended is every 30 60 days depending the accumulation of dust and grease If the build up on the coil consists of only light dust and debris the condenser coil can be cleaned with a simple brush Heavier dust build up may require a vacuum or even compressed air to blow though the condenser coil If heavy grease is present there are de greasing agents available for refrigeration use and specifically for the condenser coils The condenser coil may require a spray with the de greasing agent and then blown through with compressed air Be sure all electrical and mechanical parts are dry before turning on the power Never use a high pressure water wash for this cleaning procedure as water can damage the electrical components located near or at the condenser coil Do not place filter material in front of condenser coil This material blocks air flow to the coil similar to having a dirty coil For Customer Service Call 1 866 GO FAGOR www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL If you keep the Condenser clean you will minimize your service expense and lower your electrical costs Failure to maintain a clean condenser coil can initially cause high temperatures and e
15. xcessive run times Continuous operation with dirty or clogged condenser coils can result in compressor failures Neglecting the condenser coil cleaning procedures WILL VOID YOUR WARRANTY associated with the compressor or cost to replace the compressor Drain Maintenance Each unit has a drain located inside the unit which removes the condensation from the evaporator coil and evaporates it at an external condensate evaporator pan Each drain can become loose or disconnected from moving or bumping the drain IF YOU NOTICE EXCESSIVE WATER ACCUMULATION ON THE INSIDE OF THE UNIT be sure the drain tube is connected from the evaporator housing to the condensate evaporator drain pan IF WATER IS COLLECTED UNDERNEATH THE UNIT you may want to check the condensate evaporator drain tube to be sure it is still located inside the drain pan The levelling of the unit is important as the units are designed to drain properly when a level surface if your floor table is not level this can also cause drain problems Be sure all drain lines are free of obstructions typically food product is found blocking drain lines causing water to back up and overflow the drain pans For Customer Service Call 1 866 GO FAGOR www fagorcommercial com VTP SERIES OPERATIONS AND SERVICE MANUAL 6 TROUBLE SHOOTING Sometimes working failures are due to simple causes which can be solved by the user Before asking for the help of a qualified technician you have to do so