Home

Likorall 242/243/250™

image

Contents

1. Transport and Storage During transportation or when the lift is not to be used for a long time the emergency stop should be engaged The environment where the lift is transported and stored should have a temperature of 10 40 C 50 104 F and a relative humidity of 30 to 75 The air pressure should be 700 1060 hPa Recycling For instructions on how to recycle your Liko product please visit our website www liko com Product Changes Liko s products undergo continuous development which is why we reserve the right to make product changes without prior notice Contact your Liko representative for advice and information about product upgrades Design and Quality by Liko in Sweden Liko is quality certified in accordance with ISO 9001 and its equivalent for the medical device industry ISO 13485 Liko is also certified in accordance with environmental standard ISO 14001 4 Liko A CEED company www liko com Manufacturer Liko AB SE 975 92 Lulea Sweden info liko se Copyright Liko AB 2010 02
2. s strap loops are correctly connected to the sling bar hooks when the sling straps are extended but before the patient is lifted from the underlying surface A Never leave a patient unattended during a lifting situation C Intertek Likorall 242 ES ES R2R 242 S S R2R 243 ES 250 ES have been tested by accredited testing institutes and comply with the requirements for MDD Class 1 products MDD 93 42 EEC Likorall complies with the requirements of EN ISO 10535 IEC 60601 1 EN 60601 1 2 ANSI AAMI ES60601 1 and CAN CSA C22 2 no 60601 1 A under no circumstances must the lift be modified If you have any questions please contact Liko Particular care must be observed when using strong sources of disturbance such as diathermy etc so that diathermy cables are not positioned on or near the lift If you have questions please consult the responsible assistive device technician or the supplier The lift may not be used in areas where flammable mixtures may occur for example in areas where flammable goods are stored Likorall 242 243 250 7EN120115 01 2 www liko com Definitions a N Likorall 1 Connection hand control 2 Indication charging 3 End cover 4 Emergency stop 5 Emergency stop cord 6 Emergency lowering raising electrical 7 Outlet for transfer motor contact rail exclusively ES 8 IR receiver exclusively ES 9 SSP Limit Switch 10 Strap stop exclusi
3. 1Liko A rD Company Likorall 242 S ES Likorall 242 S ES R2R Likorall 242 243 250 Instruction Guide English 7EN120115 01 2010 02 15 Applies to the following models Prod no 3122005 3122006 Prod no 3122007 3122008 Prod no 3122009 3122010 Prod no 3122011 3122012 Prod no 3123001 Prod no 3123002 Prod no 3122501 Prod no 3122502 Likorall 242 ES Likorall 242 ES R2R Likorall 242 S Likorall 242 S R2R Likorall 243 ES natural Likorall 243 ES white Likorall 250 ES natural Likorall 250 ES white Likorall 250 ES Product Description Likorall is one of the world s most popular overhead lift motors Likorall is designed and developed for Liko s complete range of fixed installed and free standing lift systems A Liko lift system is always close at hand and easy to use All common lifts and transfers can be performed using Likorall for instance between bed wheelchair to from floor toilet visits gait training and together with stretchers Likorall R2R room to room enables the patient to be moved between two rail systems in separate rooms without connecting rails and without making holes over doors Likorall with the ES designation is prepared for operation with the wireless HandControl Remote IR and in addition a Transfer Motor can be connected for motor driven movement of Likorall ES along the rail Accessories A large and complete range of accessories are ava
4. Contact Liko for further information SlingBar Cover Paddy 30 Fits Universal SlingBars 350 450 and 600 as well as SlingBar Slim 350 Hang up HandControl Hanger Sold in set of 10 pcs Multi Connector Intended for installation on Likorall for control of switches and or if the rail system is equipped with a MultiStation for charging via the rail Transfer motor Likorall ES Fits Likorall with ES designation Max 250 kg 550 Ibs HandControl Remote IR Likorall with ES designation can be equipped with a wireless hand control IR The hand control operates normally within a range of 0 5 meters 0 196 inch from the lift Quick Release Carriage LR Fits the Quick release Adapter LR prod no 3126009 Quick Release Adapter LR Fits Quick Release Carriage LR prod no 3126008 Easy Switch Developed for users patients who have reduced strength or movement of the hand Easy to install on the hand control 2 button 4 button Fits Likorall hand controls prod no 3126034 3126035 and 3126036 Likorall 242 243 250 7EN120115 01 10 Prod Prod Prod Prod Prod Prod Prod Prod Prod Prod no no no no no no no no no no 3156025 3607001 3156100 3126111 3126044 3126060 3126008 3126009 3107010 3107011 No LikoScale 350 Prod No 3156228 www liko com Parking Panel 600 LR MR Parking Panel 1500 LR MR Can be co
5. R and the transfer can be carried out in the next room NOTE To free the Q link from the Universal SlingBar R2R it may be necessary to let out additional strap from Lift 1 Likorall 242 243 250 7EN120115 01 8 www liko com Maximum Load Different maximum loads may apply to different products on the assembled lift system lift sling bar sling and any other accessories used For the assembled lift system the maximum load is always the lowest maximum load rating for any of the components For example a Likorall which is approved for 200 kg 440 Ibs can be equipped with a sling bar which is approved for 300 kg 660 Ibs In this case the maximum load of 200 kg 440 lbs applies to the assembled lift system Study the markings on the lift and lifting accessories or contact your Liko representative if you have any questions Recommended Lifting Accessories A Using lifting accessories other than those approved can entail a risk The Liko assortment contains many sling bars slings stretchers scales and other accessories to solve most lifting needs Below is a list of lifting accessories suitable for Likorall To select suitable slings and other lifting accessories please see the Lifting accessories brochure For additional guidance in selecting a sling study the instruction guide for the respective sling models Here you will also find guidance for combining Liko s sling bars with Liko s slings Contact your Liko represen
6. Switch from for instance the strap stops Q link or if the lift strap is subjected to harmful strain for example if it is pulled sideways or folded over during the lifting motion If the SSP Limit Switch is activated so that the lifting motion stops the lift can once again be operated after the lift strap is straight again a short delay in the lifting motion is normal in these cases The SSP Limit Switch protects the lift motor from mechanical strain and it also prevents squeeze injurie A Ensure that the lift strap is kept straight and stretched when it runs in and out of the lift motor A Indication charging Likorall indicates in two ways that the battery needs charging e Buzzer sounds when lifting LED A flashes red when lifting When either of these signals sounds or illuminates the lift should be charged as soon as possible See Charging the batteries page 7 Likorall 242 243 250 7EN120115 01 www liko com Charging the Batteries Green Yellow White _j no function it N Z In order to ensure maximum battery life it is important to charge the batteries regularly We recommend that you charge the batteries after use or every night Full charge is achieved after max 8 hours Fully charged batteries will last for approximately 60 lift cycles 1 Check that the emergency stop button is not pressed 2 Place the hand control
7. ch system Aliko Biko Lika QLiko Fits Likorall All ES ES ES ES Ne A Hand Control Likorall Likorall is operated with a light push on the buttons of the hand control The arrow directions should be the same as the direction shown in the illustration The movement ceases when the button is released For the Likorall ES there is a number of hand controls to choose from depending on how the lift and rail system are equipped and an IR hand control for wireless operation If needed the lifting motion can also be controlled without hand control via the buttons and respectively on the end cover of the lift see page 6 Likorall 242 243 250 7EN120115 01 4 www liko com Emergency stop For emergency stop pull the red emergency stop cord To reset turn the button in the direction of the arrows The red cord on the lift motor s end cover is intended for use if an emergency situation occurs a Q4ink Xo N o 2 p Lifting accessory with quick release hook Likorall 242 R2R 243 ES 250 ES Push down the red catch and connect the quick release hook to the Q link Release and check that the catch locks in order to prevent involuntary unhooking from the Q link Read more about Liko s Quick release Hook system on page 9 N t Ne A Mechanical emergency lowering Likorall 242 S ES 1 Move the emergency lowering handle up and down until the patient has been lowered and the
8. e free operation certain details should be checked each day the lift is used e Inspect the lift and check to make sure that there is no external damage e Check the sling bar attachment e Check the lift strap for wear and to ensure the strap is not twisted e Check the functionality of the safety latches e Check the operation of the lift movement e Check to make sure that the emergency lowering functions correctly e Check that the mechanical emergency lowering functions and that the lifting height is set correctly e Charge the batteries each day the lift is used and check to ensure that the charger works When necessary clean the lift with a moist cloth using warm water or disinfectant NOTE Do not use cleaning agents that contain phenol or chlorine since these can damage aluminium and plastic materials A The lift should not be exposed to running water Service Likorall should be periodically inspected at least once a year A Periodic inspection repair and maintenance should be performed only in accordance with the Liko Service Manual and by personnel authorized by Liko and using original Liko spare parts Service Agreement Liko offers the opportunity to enter into service contracts for the maintenance and periodic inspection of your Liko products Expected Life Time The product has an expected life time of 10 years when correctly handled serviced and periodically inspected in accordance with Liko s instructions
9. ilable for Likorall including many different sling models in several sizes and designs In this document the person being lifted is referred to as the patient and the person helping is referred to as the caregiver Aisa warning triangle used for situations which require extra care and attention i IMPORTANT Read the instruction guide for both the patient lift and lifting accessories before use Lifting and transferring a person always involves a certain level of risk It is important to completely understand the contents of the instruction guides The equipment should be used only by trained personnel Please contact Liko in the event of any uncertainties or questions Table of Contents Safely IMStHUICHONS eera e O AO 2 De TINITIONS serene EE E 3 Technical Dala cece ttre Eiraan ieee ENEE AAEE eaka EEn Ea REE 3 Measuremenl cerra nna n coasdeenns Sates dienaadeyadoaiteancneeetdeapandariniedeaeaadenee 4 ASSOMDIY sczccevestaccctees cadtscvtisscctedies saeveneccsnenteetas basdenae saan vejeanmoetes E EE 4 OPS NA OM sxerets a pecateaas eee tua sgae thie E a a a EESE aa aia Papaa EEEE 4 Charging the Batteries ccs as ccnesticcteptviecadenseisteceestanueceapteadedadeeaeseedeaeceetea aeons 7 Transferring from room tO LOOM cceeeceeeeeeenee anr 8 Maximum Load cece eeeeeee eee eeenne ANENE ENON KENESE FENAN EEEE EAEE Aa iE 9 Recommended Lifting Accessories eessssssesrreesrssureseerrreersnnnnseesnaaaerinuneaeernneenan 9 Simple T
10. in the charger s socket 3 Connect the charger to a 100 240 V AC electric socket 4 Agreen LED illuminates to indicate that the charger is connected to the electrical grid 5 The charging starts automatically and a yellow LED indicates that the batteries are charging 6 When the battery is fully charged the charger shuts off automatically and the yellow LED turns off NOTE If the lift will not be used for a longer period of time the hand control should be placed in the charger to allow the battery to charge If the charger is not connected to a power supply the emergency stop button should be pressed in order to prevent the battery from discharging Alternative charging procedure MultiStation Prod No 3126110 As an alternative to charging via the hand control the batteries can be charged with a MultiStation installed on the rail system In this case Likorall must be equipped with a contact rail or a transfer motor The batteries are then charged by parking the lift in the charging position under the MultiStation see figure This charging procedure is also suitable when Likorall is operated by HandControl IR x Used batteries are to be deposited at the nearest recycling facility or given to personnel authorized by Liko Likorall 242 243 250 7EN120115 01 7 www liko com Transferring from room to room Liko s R2R Room to Room system is an effective
11. k Palaa e Hook niversa The Quick release Hook Universal fits the Universal SlingBar 350 450 and 600 Prod No 3156508 prod no 3156074 3156076 Quick release Hook TDM fits the SlingBar Mini 220 prod no 3156005 Sling Cross bar 450 and 670 prod no 3156021 and 3156018 and Universal TwinBar 670 prod no 3156077 See the Guide to Liko s Quick release Hook System which can be downloaded from our website www liko com or contact Liko for more information about the Quick Release Hook N TDM advantages and uses of the Quick release Hook system Prod No 3156502 gt Likorall 242 243 250 7EN120115 01 9 www liko com Stretcher All stretchers in Liko s product range can be used with Likorall Contact Liko for further information Scale For weighing persons in combination with the Likorall we recommend LikoScale 350 This can easily be installed with the LikoScale Adapter Kit Please contact Liko for more information Liko Support Springs for bounce and gait training Is used in order to produce a softer springy motion during gait training The springs are available in two sizes short prod no 3156512 and long prod no 3156511 These springs are intended for patient weights up to 70 kg 154 Ibs For patient weights up to 100 kg 220 Ibs prod no 3156513 short Also see the instruction guide for Liko MasterVest models 60 and 64 or Liko LiftPants model 92 for more information Liko Bathing Chair
12. ko com Measurements i ANNAN Lateral view lA e at CSP Central Suspension Point _ y y Esi S Lag isi Overhead view Cc va q y d B gt Toa S a D Measurements in mm A B C D H eer 165 340 250 293 210 335 2000 models 242 S ES R2R 243 ES 250 ES models 242 S ES Measurements in inch A B C p H LE 6 49 13 38 9 84 11 53 8 67 13 18 78 74 models 242 S ES R2R 243 ES 250 ES models 242 S ES Minimum distance from ceiling to CSP at maximum lifting height Built in dimension the distance between the attachment point for the lift unit on the carriage and the CSP at maximum lifting height Lifting interval the distance between maximum lifting height and minimum lifting height measured in CSP Assembly Er Handle reinforcement exclusively Likorall 242 S ES Press the reinforcement included in the bag containing the instruction guide labelled Emergency lowering onto the emergency lowering handle X Operation N HandControl H i Remote IR Button functions O Lifting movement Up Down 5 0 oo eo gt S Movement direction Transfer motor Control Swit
13. lift strap is com pletely slack Always ensure that the emergency lowering is made to a bed wheelchair or other suitable location 2 After mechanical emergency lowering has been performed resetting adjustment of the lifting height is required Lower the sling bar so that the lift strap is completely slack Hold down the emergency lowering handle halfway Simultaneously tighten the lift strap by turning the black wheel counter clockwise with the other hand Repeat until the desired height has been achieved Likorall 242 243 250 7EN120115 01 5 www liko com F F o ee ae TP 3 A Electrical emergency lowering Carriages with adjustable friction brake Emergency lower by pushing The amount of drag along the rail can be in the button on the end cover adjusted on carriages equipped with a of the lift Always ensure that the friction brake Turn the brake clockwise emergency lowering is made to for increased resistance and counter a bed wheelchair or other suitable clockwise to reduce resistance location The following carriages have a friction brake prod no 3126011 and 3126015 Hang up HandControl Hanger When not in use the hand control can be hung on the Hang up Hand control hanger Me j A SSP Limit Switch The lifting motion is stopped electrically with a light touch on the SSP Limit
14. mpleted with the following accessories Hook for SlingBar Hook for Accessories Bracket for Charger Quick Reference Guide see respective product Prod Prod Prod Prod Prod no 3126075 no 3126080 no 3126070 I no 3126071 no 3126100 Simple Troubleshooting The lift doesn t work A repeated signal can be heard from the lift The lift stops in the high position The lift does not achieve maximum lifting capacity You hear unusual sounds Likorall 242 243 250 7EN120115 01 11 Check to ensure that the emergency Check that the hand control is correctly Charge the battery If the lift still does not work properly stop button is not pressed in connected please contact Liko Charge the battery immediately If the lift still does not work properly please contact Liko Check to ensure that the emergency stop E button is not pressed in Check that the hand control is correctly connected Use the selected mechanical or electrical emergency lowering device to lower the patient onto a firm surface Charge the battery If the lift still does not work properly please contact Liko mb a Charge the battery If the lift still does not work properly please contact Liko Please contact Liko www liko com Inspection and Maintenance Care and Maintenance For troubl
15. roubleshooting sses nan EEEE EEEE EN 11 Inspection and Maintenance ccccceceeeeeeceeceeeeeeeeeeececaeaeeaeeeeeeeeteeeeesnnaeas 12 NOTE This instruction guide contains important information for users of the product All those who use the product should review and fully understand the contents of the instruction guide Remember to keep the instruction guide in a place where it is always available to those using the product Safety Instructions A Installation of Likorall to rail carriages must to be made by personnel authorized by Liko and in accordance with the current installation instructions Before using the first time make sure that Before lifting always ensure that e the lifting accessories are properly attached to the lift the lift strap is not twisted or worn and can move e the batteries have been charged for at least 8 hours in and out of the lift freely you have read the instruction guide for the lift and e the lifting accessories are not damaged lifting accessories e the lifting accessory is correctly and securely applied e personnel using the lift are informed of the correct use tO the patient in order to prevent injuries of the lift and lifting accessories e the lifting accessories are properly attached to the lift e the lifting accessory is selected appropriately in terms the lifting accessories hang vertically and can move of type size material and design with regard to the freely patient s needs the sling
16. solution for safe and easy transfer of patients between two or more rooms The R2R system is mounted without making openings in walls over doors and full isolation is therefore retained between the rooms supported by the system The transfer is performed in a safe and easy manner with the aid of separate rail systems for each room Liko s R2R system enables linking together two Likorall when transferring from room to room The actual transfer operation between two rooms is performed with a comfortable transition for the patient from one Likorall to another C N A Lift 2 L A Mounting Universal SlingBar R2R Room to Room 1 Move Lift 1 with the patient as close to the door way The Universal SlingBar R2R has a double hook with as possible Lower the lift as far as possible bearing Quick release The double hook has protection against in mind the patient s comfort unintentional detachment 4 N Lift 2 2 Move Lift 2 as close to the door opening as possible 3 Raise Lift 2 The patient is successively moved Lower the lift strap from Lift 2 a sufficient length to the next room and finally suspended in Lift 2 and connect the Q link to the Universal SlingBar R2R only When the pressure is relieved from the lift Check that the safety latches on the R2R connector strap for Lift 1 disconnect the lift strap from function properly the Universal SlingBar R2
17. tative or visit www liko com for advice and information on Liko s product range SlingBar Mini 220 Prod no 3156005 G N Max load 205 kg 450 Ibs Universal SlingBar 350 with Quick release Hook Prod no 3156084 E Fixed connection prod no 3156074 Max load 300 kg 660 Ibs Universal SlingBar 450 with Quick release Hook Prod no 3156085 Fixed connection prod no 3156075 Max load 300 kg 660 Ibs I Universal SlingBar 600 with Quick release Hook Prod no 31560868 E SD Fixed connection prod no 3156076 Max load 300 kg 660 Ibs wp Universal SlingBar 670 Twin with Quick release Hook Prod no 3156087 CE Fixed connection prod no 3156077 Max load 300 kg 660 Ibs meg Universal SideBars 450 Prod no 3156079 Qe H including bag AN E Max load 300 kg 660 Ibs a Sling Cross bar 450 with Quick release Hook Prod no 3156022 ae A Fixed connection prod no 3156021 C Max load 300 kg 660 Ibs W Sling Cross bar 670 with Quick release Hook Prod no 3156019 5 Fixed connection prod no 3156018 ae gt D Max load 300 kg 660 Ibs 4 Sling bars with fixed connection can be equipped with Quick release Hook Quick Release Hook Liko s Quick release Hooks are a system for quick change of lifting accessories on Liko s mobile and stationary lifts equipped with the Q link The Quick release Hook can be installed on lifting accessories with a fixed connection Sulo
18. vely 242 S ES 11 Movable strap stop exclusively 242 S ES 12 Hang up HandControl Hanger 13 Mechanical emergency lowering exclusively 242 S ES 14 Hand control with wire 15 Q link exclusively 242 R2R 243 ES 250 ES a i J Technical Data Maximum Likorall 242 200 kg 440 Ibs Emergency Mechanical Likorall 242 S ES load Likorall 243 230 kg 507 Ibs lowering device Electrical Likorall 242 S ES R2R Likorall 250 250 kg 550 Ibs Likorall 243 ES Likorall 250 ES Batteries 2 x 12 V 2 6 Ah Valve regulated lead acid Intermittent Int Op 10 90 active operation gel type batteries New batteries operation max 6 min are provided by the supplier d level 49 dB Battery SMP CC 10 43 24 100 240 V AC 40 60 Hz Sound leve au charger max 600 mA Protection class IP 43 Lifting l Protection class speed 50 mm s 2 inch s hand control IP 43 Lifting Operating forces interval 2000 mm 77 8 inch of controls 5N 242 S ES vertically adjustable Electrical data 24 V 12A 3 Intended for indoor use Lift motor Likorall 242 S ES 13 0 kg 28 6 Ibs Type B in accordance with the electrical shock weight Likorall 242 R2R 13 2 kg 29 lbs protection class Likorall 243 ES 250 ES 12 6 kg 27 7 lbs Likorall is equipped with a SFS Single Fault Safety safety drum This patented safety design provides protection against uncontrolled lowering The lift strap has a tenfold safety Likorall 242 243 250 7EN120115 01 3 www li