Home

installation & service manual

image

Contents

1. Clean Water Solutions 293 Wright Street Delavan WI 53115 Phone 1 800 937 6664 www omnifilter com Filters Fast 866 438 3458 sales filtersfast com www filtersfast com
2. Install the white tube insert into the end of the red tubing d Push the red tubing with the white insert into the angle needle valve e Use a wrench to securely tighten the hex chrome plated compression nut with the matching compression thread f Do not use Teflon tape on this compression connection Printed in the U S A 11 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com 866 438 3458 www filtersfast com filters fast STEP 3 MOUNTING THE TANK BALL VALVE Note Do not tamper with the air valve on low side of storage tank It has been preset at 8 10 psi by the manufacturers 1 Unplug the plastic cap on the top of the tank 2 Wrap the thread 3 times with plumbers Teflon tape only 3 Connect the ball valve to the thread Make sure it is tight but not over tight See lt Fig 5 gt 4 Connect the yellow tubing from to the tank ball valve Turn the tank ball valve off VV BLPO14WJG Qi ES OFF POSITION ON POSITION dr TOP VIEW OF TANK BALL VALVE lt ON POSITION lt Fig 5 gt STEP 4 MOUNTING THE DRAIN CLAMP The drain clamp will fit most standard drain pipe 1 1 4 It should be installed above the trap and on the vertical tailpiece See lt Fig 6 gt 1 Position the drain saddle in desired location mark spot through thread outlet remove saddle 2 Drill 1 4 6 3mm hole into the drain pipe above the water line of trap 3 Align the ho
3. Se Flex line assembly Solid copper line assembly lt Fig 3 gt lt Fig 4 gt Feed water adapter components Feed water adapter assembly Printed in the U S A 10 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com fil ers ast 866 438 3458 com www filtersfast com 4 Please follow Fig 4 for flex line and solid copper riser installation a Flex line Loosen nut and separate cold water riser tube from faucet shank Gently bend riser tube so that feed water adapter fits onto faucet shank Replace the existing cone washer with the new washer if needed The new washer is provided in the installation kit Reinstall riser tube onto feed water adapter VV WWC 1 and tighten b Solid copper riser tube follow procedure 4a except you may need to cut a piece of the riser tube about 3 4 or 1 so the feed water adapter can fit between the faucet and riser tube 5 Connect red tubing to angle needle valve VV WNV 4 Hex chrome plated compression nut White plastic ferrule DO NOT apply Teflon P tape on this pipe thread a White T d au t din Angle needle valve E el i vod VV WNV 4 amp ry VM Nn es Feed water tubing connection DO apply Teflon tape on this pipe thread a Slide the hex chrome plated compression nut with the thread facing the end of the red tubing b Slide the white plastic ferrule onto the red tubing c
4. This hole can be used for the RO faucet skip to step 6 2 Place a piece of masking tape or duct tape on the determined location where hole is to be drilled 3 Use a variable speed drill at slow speed with a 1 8 3 mm drill and drill a centering hole in the center of the desired faucet location Use lubricating oil to keep the drill bit cool while drilling 4 Enlarge the hole using a 1 4 6 4 mm drill bit Use factory approved method or approved plumbing practice to drill hole in sink 5 Enlarge the hole to 1 1 4 diameter Keep bit well oiled and drill slowly 6 Slide the large chrome escutcheon base plate and the matching large rubber washer in that order over the faucet stud at the bottom of the faucet 7 Firmly push the provided black 3 8 tube over the large barb fitting on the bottom of the faucet The tubing may not push all the way to the end of the connection but must be installed securely over the barbed portion of the fitting to prevent leaks Leave the full length of tubing attached at this time as it will be trimmed in a subsequent step 8 Feed the black 1 4 tubing attached to the membrane housing through the hole in the sink Trim this tubing so there 15 only 12 more than needed to make a comfortable installation Firmly push the black 1 4 tube over the small barb fitting on the bottom of the faucet The tubing may not push all the way to the end of the connection but must be installed securely over the barb
5. housing Make sure the O ring 15 in place and turn the housing clockwise to close f Repeat previous step on the subsequent filter changes g Turn on the water supply and make sure there are no leaks Let the water drip from faucet for about 10 minutes If the water flow 15 less than 1 cup 8 oz or 240 ml per minute it may be an indication to change the membrane 1 Membrane change procedures Unscrew the cap of the membrane housing e Slid out the used membrane and discard nsert the new membrane with 2 o rings into housing first the black brine seal around membrane last Be sure it is fully seated into bottom end e Screw cap back on to the membrane housing make sure o ring is still in place t may take 10 20 minutes for new membrane to run to normal flow If the water flow is OK then turn on the tank ball valve After 1 minute turn off the RO faucet and complete the filter change procedures Printed in the U S A 14 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters fast TROUBLE SHOOTING Note Turn off the system before servicing PROBLEM CAUSE SOLUTIONS Milky colored water Noise from faucet Small amount of water from storage tank Slow production Water taste or smell offensive Air in system V Air gap faucet 7 Location of drain saddle Restriction in drain line System just starting up v Air pressure in s
6. to complete 7 After the second tank 15 filled you may enjoy the pure water 8 Check leaks daily for first week and periodically thereafter 9 You may notice that the water may be milky colored during the first week It may be air in the water It is normal and safe NOTE 1 Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts 2 This reverse osmosis system contains a replaceable component critical to the efficiency of the system Replacement of the reverse osmosis component should be with one of identical specifications as defined by the manufacturer to assure the same efficiency and contaminant reduction performance WARNING Do not use this RO system appliance to purify non drinkable sources of water that are unsafe or with water of unknown quality BH WARNING Never use hot water or freeze unit WARNING Incorrect installation will VOID the warranty Printed in the U S A 13 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters ast 866 438 3458 ECT www filtersfast com PREVENTIVE MAINTENANCE This recommendation is intended for maximum efficiency of RO water production by your system 1 Filter maintenance a It is OK to put filters o
7. 866 438 3458 www filtersfast com INSTALLATION amp SERVICE MANUAL Under the sink Reverse Osmosis System Model RO2000 Series B System Tested and Certified by NSF International against NSF ANSI Standard 58 for the reduction of Barium Cadmium Copper Cyst Hexavalent Chromium Lead Radium 226 228 Selenium TDS Trivalent Chromium as verified and substantiated by test data OMNIFILTER Clean Water Solutions 293 Wright Street Delavan WI 53115 Phone 1 800 937 6664 www omnifilter com Copyright 2006 OMNIFILTER Printed in the U S A Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters ast 866 438 3458 com www filtersfast com hank you for choosing an Omni RO2000 Reverse Osmosis Drinking Water System With proper care your water filtration system will produce high quality drinking water for many years Read carefully and follow the instructions in this manual before proceeding with the actual installation Pay particular attention to all warnings cautions and notes Failure to do so could result in personal injury or damage to the equipment or other property System and installation needs to comply with state and local laws and regulations If you have any questions please contact us at 800 937 6664 CHECK LIST 1 RO2000 Reverse Osmosis Unit 2 Water storage tank 5 gallon volume 2 8 gallon 40 51 3 Installation kit tank ball valve drain saddle valve fee
8. PTIONS SERVICE LIFE Warranty RO2000 Series B Reverse Osmosis Systems are warranted to the original owner to be free of defects in material and workmanship from the date of manufacturing for one year While testing was performed under laboratory conditions actual performance may vary Printed in the U S A Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters ast 866 438 3458 JEUX T www filtersfast com Performance Test Data Model RO2000 Series B Maximum Permissible Product Water Concentration mg L Chromium Hexavalent 0 0 Influent Challenge Substance Concentration mg L 0 1 1 Substance Influent Challenge Concentration Reduction Requirement Minimum 50 000 mg L 99 95 Performance Indication A sampling kit for analysis of TDS The Omnifilter model RO2000 Series B reverse osmosis system contains a replaceable treatment component critical for effective reduction of TDS Total Dissolved Solids The product water shall be tested periodically to verify that the system 15 performing satisfactorily The TDS sampling kit is included with this system in a separate bag This sampling kit will be used to compare your kitchen tap water against the reverse osmosis drinking water to determine if the membrane needs to be replaced This sampling kit includes Two 2 sample bottles with labels one 1 Padded envelope with mailing
9. Plat Rubber Washer lt Completed Air gap faucet installation Blue 1 4 tubing Black 1 4 tubing Black 3 8 tubing Printed in the U S A 9 Copyright 2006 OMNIFILTER fil erst asl 866 438 3458 www filtersfast com STEP 2 CONNECTING TO THE COLD WATER LINE Caution The water supply to your unit MUST be from the COLD WATER LINE Hot water will severely damage your R O System 1 Locate cold water angle stop shut off valve underneath the sink and turn it off Open cold water faucet to release the pressure If water continues to come out of faucet with angle valve turned off the house main will have to be turned off 2 Locate feed water adapter V V WWC 1 in the installation kit The angle needle valve VV WNV 4 should be installed into the feed water adapter VV WWC 1 prior to connecting assembly to the feed water line See figure 3 To prevent leaks teflon tape must be applied to the angle valve pipe threads that connect to the feed water adapter Do not put teflon tape on the needle valve threads for the compression nut 3 Disconnect the cold water riser tube and install the feed water adapter DO apply Teflon tape on this pipe thread Red Tubing DO NOT apply Teflon tape on this pipe thread Solid Copper Line Compression Nut 539 Flex Line Red Tubing Angle stop shut off valve 3 8 R T T zz ls TT m i Yu eal b b ig Ghee E EREE N Has
10. SS pe pome 4TH STAGE 3RD STAGE KI 1 TO FEED WATER p ae PRESSURE TANK M ncn 2nd STAGE 1ST STAGE Sediment filter Please contact your local dealer at Ist stage 2nd stage Carbon filter or call OMNIFILTER at 1 800 937 6664 3rd stage TFC membrane 4th stage Inline carbon filter Auto shut off valve Operating pressure 50 90 PSI Operating temperature 40 100 F Recovery rate 1690 REPLACEMENT PARTS OMNI ITEMZ DESCRIPTIONS SERVICE LIFE OMI TFC membrane 24 36 months R200 Inline carbon filter Printed in the U S A 3 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters ast COM Performance Data Sheet Model RO2000 Series B Operating Pressure 50 90 PSI Operating Temperature 40 100 F Water Hardness lt 120 ppm 7 gpg pH Range 3 11 TDS 1000 ppm The performance claims are made by the RO2000 Series B This system has been tested according to NSF ANSI 58 for the reduction of the substances listed below The concentration of the indicated substances in water entering the system was reduced to a concentration less than or equal to the permissible limit for water leaving the system as specified in NSF ANSI 58 Function Barium Reduction Cadmium Reduction Copper Reduction Cyst Reduction Hexavalent Chromium Reduction Lead Reduction Radium 226 228 Reduction Seleniu
11. d water valve faucet assembly 4 Four colored tubings black red yellow blue 4 feet each color 5 Manual and warranties isat 4 Imm B ro Te 3 Installation Kits ign 0 1 Reverse Osmosis Unit 2 Water Storage tank 4 Four colored tubing 5 Gallon Attached to RO unit RECOMMENDED TOOLS LIST Variable speed drill 1 8 and 1 4 drill bits 7 8 drill bit 1 2 and 9 16 open end wrenches or adjustable Phillips screwdriver k Utility knife Teflon tape This reverse osmosis system contains a replaceable treatment component critical for effective reduction of total dissolved solids The product water shall be tested periodically to verify that the system 15 performing satisfactorily System Tested and Certified by NSF International against NSF ANSI Standard 58 for the reduction of Barium Cadmium Copper Cyst Hexavalent Chromium Lead Radium 226 228 Selenium TDS Trivalent Chromium Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after the system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts Printed in the U S A 2 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com 866 438 3458 www filtersfast com filters ast com 0 O o RO2000 FILTRATION PROCE
12. ed portion of the fitting to prevent leaks Air Gap Faucet Air Gap Window Escutcheon Plate Black Rubber Washer Counter Top Black Locating Washer 7 me d Washer Split Washer Washer Connect to 3 8 onnect to 1 4 Black Tubing lack Tubing Brine Output Brine Input Connect to 1 4 Blue Tubing Printed in the U S A Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filtersfast 866 438 3458 Com www filtersfast com 9 From above the sink pass the black 3 8 drain tube through the hole in the sink Installation of the faucet from this point 15 far easier with a helper 10 Hold the faucet centered in the hole and in the desired position Be sure the large rubber seal 15 centered under the large chrome escutcheon base plate 11 From underneath the sink position the following parts in this order Install the large split washer plastic spacer plastic spacer 1s installed with the open side facing up and parallel with the black tubes metal flat washer internal locking washer and hex nut onto the faucet stud Discard the included small rubber washer as it is not used with the faucet provided for this system 12 While maintaining all parts in the centered and desired position carefully and securely tighten the hex nut on the faucet stud A basin wrench 15 handy for this step WARNING Over tightening the faucet to the sink
13. label and one 1 Instruction sheet Printed in the U S A 5 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filtersfast 866 438 3458 Com www filtersfast com Please follow by 4 color coded tubing connection to complete installation AIR GAP N RO FAUCET Tul CAUTION When cutting supplied tubes predetermine the length by measuring the distance between the components to be connected BLACK TUBING 3 8 YELLOW TUBING 1 4 BLACK TUBING 1 4 No tools are needed to RED TUBING 1 4 connect 4 colored 3 JL O STORAGE TANK tubes Secure connections are simple Cut the tube square and push past the O ring to the tube stop i Tube is secured in position Aaa g emwedhu Colar or Taing Feed Water Valve Feed Water to RO System Tank Ball Valve RO Water to Storage Tank D Air Gap Connector Black 1 4 Discharge Water to Air Gap Faucet Black 3 8 Discharge Water From Air Gap Faucet to Drain Printed in the U S A 6 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters ast 866 438 3458 C C www filtersfast com INSTALLATION STEP 1 INSTALLING THE FAUCET 1 Determine the desired location for your RO faucet on your sink surface There maybe an existing hole in the back area of the sink for use with a sprayer or soap dispenser
14. le drilled in the drain pipe with the drain saddle using a drill bit or other narrow straight object and tighten clamp 4 Make sure to align drain saddle to drilled hole Attach drain saddle to drain pipe and tighten the two screws evenly See lt Fig 7 gt 5 Connect 3 8 black tubing to drain clamp DRAIN PIPE Printed in the U S A 12 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filtersfast 866 438 3458 Com www filtersfast com STEP 5 SYSTEM START UP 1 Turn on the cold water supply and the under sink feed water valve but close the tank ball valve 2 Open RO faucet lever to the up position for continuous flow 3 Check system for leaks tighten as necessary 4 After 10 30 minutes the water will start to drip out of the RO faucet Let it drip for about 10 minutes and then flip the handle to the closed position TURN ON THE TANK BALL VALVE NOW It will now take several hours 2 3 for the storage tank to fill depending on the local water pressure DO NOT DRINK THE WATER FROM THE FIRST TANK PRODUCED BY YOUR NEWLY PURCHASED SYSTEM 5 After the tank 15 full you will hear the water stop flush the system by placing the RO faucet in the open position until the water 1s completely discharged 6 Upon complete discharge of storage tank flip handle to closed position on RO faucet and let the refilling process begin This process could take 2 3 hours
15. m Reduction TDS Reduction Trivalent Chromium Reduction 866 438 3458 www filtersfast com OMNIE EFR Clean Water Solutions 293 Wright Street Delavan WI 53115 Phone 1 800 937 6664 Specifications Daily Production Rate Volume of Unit Recovery Rate Pressure Drop at Rated Flow System Weight System Dimension 15x5 5x17 5 Test parameters of 25 1 C 50 psi and pH of 7 5 5 System tested and certified by NSF international against NSF ANSI Standard 58 for the reduction of Barium Cadmium Copper Cyst Hexavalent Chromium Lead Radium 226 228 Selenium TDS Trivalent Chromium General Installation Operation Maintenance Requirements Installation needs to comply with state and local laws and regulations Do not use with water that is microbiologically unsafe or of unknown quality without adequate disinfection before or after system Systems certified for cyst reduction may be used on disinfected water that may contain filterable cysts e This system shall only be used for arsenic reduction on chlorinated water supplies containing detectable free chlorine residual and should provide a one minute chlorine contact time before the RO system e This reverse osmosis system contains a replaceable treatment component critical for effective reduction of total dissolved solids The product water shall be tested periodically to verify that system is performing satisfactorily Replacement Parts OMNI ITEM DESCRI
16. may damage the faucet and or sink 13 Install the provided John Guest 9 quick connect fitting to the bottom of the faucet stud Securely push the blue 1 4 tube coming from the horizontal inline post filter into this fitting 14 The black 3 8 tube previously connected to the faucet will need to be attached to the drain connector that will be installed in a later step It is of utmost importance that this 3 8 tube be trimmed so there 15 little extra tubing from the connecting points There can be no loops sharp bends or kinks in this tube When installed the drain clamp must be lined up with the hole to be drilled 1n the drain pipe The air gap faucet must always have unrestricted flow from the faucet to the drain A restriction in this portion of the system will result in water dripping or leaking from the small hole on the side of the faucet just under the dispensing handle 15 The faucet dispensing handle may be pushed and held down for instant water or pulled up into the locked position for continuous flow Printed in the U S A 8 Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com Drain Connector Dispensing Handle Plastic Spacer Metal Flat Washer TT Internal Locking Washer B 2 2 PAZ 4 Faucet Stud EET y JU Pug John Guest Quick Large COM Connect Fitting Split Washer Chrome Escutcheon Base
17. n the shelf for several years b To keep the sealed non opened filter we recommended to put it into some air tight container preventing it from absorbing the air This prolongs the shelf life of carbon filter particularly if you order the replacement filter for more than one years usage and avoids any possible odor from the air 2 Membrane maintenance a The dry packed membrane usually has a two year shelf life To prolong the shelf life we recommended keeping non opened dry membrane in refrigerator b Once being used we recommend you run the RO system every day at least 2 minutes about 1 gallon or 4 liters drinking water This helps to maintain the membrane performance If you do not use the RO system for long periods drain the storage tank before using Fill the tank and drain it twice Your RO system is then ready to use 3 Filter and membrane change procedures a Shut off the water supply b Turn off the tank ball valve by turning 90 degree c Open RO faucet to continuous flow position d Lift the filter housing up 1 and slid on the housing wench Use one hand to hold the system and the other hand to turn the wrench counter clockwise to open the housing Note If it is too tight to open the housing you may try to unplug the fitting between red tubing and the systems in order to reduce the air and water pressure inside the housing e After opening the housing remove the used filter and put the new filter into the
18. torage tank is low V Low water pressure Crimps in tubing v Clogged prefilters V Fouled membrane V Post carbon is depleted Fouled membrane V Sanitizer not flushed out 866 438 3458 www filtersfast com Air in the system 15 a normal occurrence with initial startup of the RO system This milky look will disappear during normal use within 1 to 2 weeks Will disappear after system shuts down B Relocate the drain to above water trap Blockage sometimes caused by debris from garbage disposal or dishwasher Normally it takes 2 3 hours to fill tank Low water pressure and or temperatures can reduce production rate Add pressure to storage tank The pressure should be 8 10 psi when the tank is empty Add a booster pump Make sure tubing 15 straight Replace prefilters Replace membrane Replace post carbon Replace membrane Drain storage tank and Refill it overnight Clogged flow restrictor Replace flow restrictor Leaks Printed in the U S A Fittings are not tightened V Twisted O ring v Misalignment of hole in drain saddle 15 B Tighten fittings as necessary Replace a o ring Realign drain saddle Copyright 2006 OMNIFILTER Filters Fast 866 438 3458 sales filtersfast com www filtersfast com filters fast 866 438 3458 QU www filtersfast com 0 FR

Download Pdf Manuals

image

Related Search

Related Contents

製品カタログ  Samsung SM-G920TRWATMB Health and Safety Guide  04-52-05-1 MU - Precia Molen  Meyer 9122 Musical Toy Instrument User Manual  SC18IS600 SPI to I2C-bus interface  Sierra Wireless Overdrive User's Manual  Qubit™ Protein Assay Kits - Ecologie Microbienne Lyon  Untitled  Acronis SharePoint Explorer  OBDII ABS y Airbag Herramienta de Escaneo  