Home

Installation Instruction

image

Contents

1. Function description More details regarding the operating modes you will find in the operating instruction of your Combi Main screen Display Room temperature timer mode 15 C Room rer 10 10 L over Status of zu EAT zd the heater Room temperature Display on when the heater is active Timer Display on when the timer Is active Clock Only if the clock has been set otherwise the Truma logo will appear in the display Status of the heater 5E Set room temperature e g 18 C EG Energy selection E Electro G Gas W Set water temperature ruma H 16 C EG Wi 0 C Selection key upwards to select functions or set values Selection key downwards to select functions or set values Selection key backwards to select values Selection key forwards to select values On Off Display and heater is switched on and or off The clock is shown when the time is set After an interruption in the operating voltage the display and the heater are switched off If the time is shown this needs to be set Green LED shines when the heater is on Green LED flashes when the heater is after running Red LED shines when there is a malfunction Manual mode In manual mode the heater is controlled via the 4 keys below the display It is not necessary to set the time because the Iruma logo is shown in the display instead of the time A pre selection between summer winter operation must
2. be made via the setup Room temperature When the menu is selected the yellow LED shines The current set room temperature is displayed and can be changed Key increases the room temperature max 30 C by 1 C Key reduces the room temperature min 5 C by 1 C A change in the room temperature needs to be confirmed with E Energy selection When the menu Is selected the yellow LED shines Depends on summer winter operation see setup Use key O or to select the energy source and confirm with E Bar shows current mode Summer operation 230 V AA 230 V 8A Gas powered electro mode 230 vV 900 W electro mode 230 V 1800 W Winter operation 230V 24A 230V 8A Gas powered 230 V 24 A and gas mixed operation gas and electro mode 900 VV 230 V 8A und Gas and gas mixed operation gas and electro mode 1800 VV electro mode 230 V 900 W electro mode 230 V 1800 W If electro or mixed operations are selected and there is no 230 V power supply the heating will not function Water temperature When the menu is selected the yellow LED shines During the heating up phase the set water temperature flash es in the main screen Use key O or 0 select the water temperature and confirm with B Bar shows current mode Depends on summer winter operation see setup Summer operation Water 40 C Water 60 C Winter operation Water gt 0 C heating without controlled wate
3. on off select on off Backlight brightness levels O 9 If no action is taken the display switches back to the main screen after a few seconds The lighting switches off after a short delay Further information see operating instructions Combi 4 E Combi 6 E Maintenance Clean the panel with a dry and fluff free cloth Disposal The device must be disposed of in line with the administrative regulations of the respective country in which it is used National regulations and laws in Germany for example the End of life Vehicle Regulation must be observed Technical data Operating voltage DC voltage 8 16 V Ambient temperature 20 C to 60 C Front panel Plastic Width 190 mm Height 110 mm Depth 29 mm Cutout dimensions 165 x 90 mm Weight 1709 The right to effect technical modifications is reserved Trouble shooting list Fault Rectification Cause Clock is not shown Set clock Activated timer is not shown Power supply was any more interrupted Room temperature Is Heater not active not shown Device does not react Interrupt power supply for any more 10 seconds Heater display does Check 12 V supply voltage not react If these measures do not rectify the problem please contact the next Truma Service point see Truma service book or www truma com Installation instructions The installation in the vehicle must comply with the technical and administrati
4. CP 25 UK Operating instructions Page 2 Installation instructions Page 8 To be kept in the vehicle ruma Htc EG WiU O E Y ruma CP 25 UK Table of contents Operating instructions Operating instructions Please be sure to read the instructions for installation o antenne ten een 2 and use before attempting to connect and use this Safety instructions 22222220222seseeeeeeeeeeeneennen 2 device Intended use cooccocccnccnncncocnnccnnnncncnnnononnnnnnnorononnnonnncnnnnnnnneninannnns 3 Initial operation or activation after a power Cut eese gt Function description 444Hmsnn seen nen 3 Symbols used MAIN SCHEEN sara aid 3 ON Off coccececcsscsssessessessessessessessessessessessessessesseasessesseesesseeseeseee 4 AN Room temperature eueneeesseeseensennnnnnnnnnnnnnnnnnnnnnnn nennen nnenn 4 Symbol indicates a possible hazard Energy selection ooccoccccocncocnnoncnconnnonnnoncncncnnnonnnncnnncnnnanncnnnnos 9 Water temperature occccocccccnccncncncocnnnnnncnnncnonnnnononcnonnnnnnnnrnnnnnns 5151101 o OP Non II EENERI AEG HUENPEERENENIR ICE NENNEN 6 Comment including information and tips Maintenance ui 6 DI DO A een ee an 6 Technical data enennen 7 Safety instructions Trouble shooting list ooooccoocccocccocnccccncocncoccnnos 7 To protect you from electrical shocks injury or burns the following basic s
5. afety principles must be observed Installation instructions when using electrical devices Please read and follow these instructions before using the device Installation Ensure that the devices are positioned safely and cannot fall down or over Always position the cables to ensure they do not pose a tripping hazard Do not expose electrical devices to rain Do not operate electrical devices in damp or wet environ ments Do not operate electrical devices close to flammable liquids or gases Position the devices so that they are out of the reach of children Protection against an electrical shock Only operate devices whose casings and cables are undam aged Ensure the cables are installed safely Do not pull on the cables Use Do not use electrical devices for purposes other than those stated by the manufacturer Repairs Do not repair or modify the device Please contact your dealer or the Truma Service see service manual or www truma com Accessories Only use accessories and additional devices that are supplied or recommended by the manufacturer Intended use The CP 25 UK is a digital operating display and control unit for the Combi 4E GE The device is designed to be installed in caravans and motorcaravans Initial operation or activation after a power cut After the operating voltage has been connected the unit will beep and the display remains dark To switch on press the key and the main screen will appear
6. hone telefax 01283 58 60 20 01283 58 60 29 sales trumauk com www trumauk com Fo O 07 2011 34020 98600 01
7. r tempera ture heating has priority Water 60 C Timer mode The heater runs in timer mode as soon as one or both timers have been activated in the setup Timer On appears in the main screen The heater is only active in the set time window active timer Only the energy selection can be changed in the case of an active timer A change in the room or water temperature will automati cally switch the control system into manual mode SET Setup In the main screen display you can enter the setup menu via the setup key The following settings can be made Back return to main screen Timer 1 on off select i on off w hlen Timer 2 on off select ti on off w hlen Summer Winter select amp summer winter Set clock Set timer 1 Back Return to main screen Start Set start time Stop Set stop time Water Set water temperature Temp Set room temperature The timer settings can be made every day until the timer is switched off If the room or water tempera ture is changed outside the timer menu the timer is automatically switched off Set timer 2 Back Return to main screen Start Set start time Stop Set stop time Water Set water temperature Temp Set room temperature The timer settings can be made every day until the timer is switched off If the room or water tempera ture is changed outside the timer menu the timer is automatically switched off Buzzer
8. ve provisions of the respective country in which it is used e g EN 1648 VDE 0100 721 National regu lations and guidelines must be observed In other countries always observe the respectively valid regulations Panel Install the panel in a place that is protected from damp and wet Prepare an installation opening for the display 65 e H de A X max 4 o I O ae 165 Dimensions in mm Connect the cable TIN Bus to the display and lead toward the heater Connect the 12 V plug and connect with the 12 V operating voltage Secure the plus cable with a 1 A fuse Connect GSM module optional The heater can be switched on remotely via the GSM module 12 V m 2 x TIN Bus Es LI Gsm View from the back Attach the panel with 4 screws 2 x TIN Bus GSM 3 View from the front Press the frame of the panel until it clicks into position The right to effect technical modifications is reserved In Germany always notify the Truma Service Centre if problems are encountered in other countries the relevant service should be contacted see Truma Service Booklet or www truma com Having the equipment model and the serial number ready see type plate will speed up processing Sales and Service in UK and Eire Truma UK Limited 2000 Park Lane Dove Valley Park Foston South Derbyshire DE65 5BG Service telep

Download Pdf Manuals

image

Related Search

Related Contents

Consultez ici le programme complet  User Manual - MAD V1.5 Deep Archive Manager V4.0  aux Lilas - Les Lilas  Samsung Galaxy 580 Uživatelská přiručka(Eclair)  HT32F125x Development Board User Manual  Endura® Serie NSM5200  Le slam s`enflamme à Brazzaville  Model 700939 FET Probe for DL Series  設計標準(PDF:381KB)  

Copyright © All rights reserved.
Failed to retrieve file