Home

RADIO ROLLER BLINDS CONTROLLER SRP-02

image

Contents

1. Lene E E 1 Disconnect power supply by the phase fuse the circuit breaker or the switch disconnector combined to the proper circuit Check if there is no voltage on con nection cables by means of a special measure equipment Connect the cables with the terminals in accordance with the installing diagram Install SRP 02 device in the junction box Switch on the power supply from the RADIO ROLLER BLINDS CONTROLLER SRP 02 MANUAL INSTRUCTION ZAMEL Sp z 0 0 XX ul Zielona 27 43 200 Pszczyna Poland tel 48 32 210 46 65 fax 48 32 210 80 04 www zamelcet com e mail marketing zamel pl DESCRIPTION Radio roller blinds controller SRP 02 is used to control roller blind drives with 230V TECHNICAL DATA SRP 02 mains y Input supply terminals L N Input rated voltage 230V AC Input voltage tolerance 15 10 Nominal frequency 50 60 Hz AC motor with a limit switch The device re alises roller blinds local and central control functions and it has the possibility of comfort gt mode adjustment Comfort modes are used to adjust roller blinds position height level and to memorise the height level Central mode is used in case of a totally closed or opened roller blind or a group of roller blinds controllers One controller with different position level Coding addressing transmission can be used for one Maximum nu
2. it suspend the rights of the PURCHASER resulting from the discrepancy equipment between the goods and the contract It is forbidden to put the used equipment together with other waste Programming push button Salesman stamp and signature date of sale J Ne nose SD VER 002_11 07 2011 OPERATION Pressing shortly the programmed push button in local mode lt 2 sec or roller blind switch optional causes the roller blind moves Another short pressing of the same push button or the switch causes the roller blind stops at a required level Pressing the push button or the switch longer gt 2 sec causes comfort mode activates the roller blind moves in a required direction and stops according to the adjusted time Pressing shortly transmitter s push button programmed in the central mode causes complete opening or closing of the roller blind RADIO TRANSMITTERS PROGRAMMING LOCAL mode Press PROG push button of SRP 02 device for Press and release transmitter s first Press and release the second a longer time until LED red diode switches on push button movement 4 LED red transmitter s push button movement v constant signal Next release PROG push button diode switches on first signal pulsates LED red diode switches on signal next the signal is constant pulsates and then switches off THE TRANSMITTER IS ADDED CENTRAL mode LZ pO TN Press PROG push button of SR
3. P 02 device for Press and release transmitter s first Press and release the second transmitter s a longer time until LED red diode switches on push button movement 4 LED red push button movement v LED red diode constant signal Next release PROG push button diode switches on first signal pulsates switches on the signal pulsates Wait for about 5 seconds till LED red diode next the signal is constant and next it switches off THE switches on first signal pulsates TRANSMITTER IS ADDED next the signal is constant An exemplary programming procedure with P 257 4 remote control The procedure for the rest of radio EXTA FREE transmitters is analogous with reservation that 2 channel transmitters can be programmed only in one mode local or central CAUTION If push button changes are required for local and central control in a 4 channel transmitter the programming procedu re should be for two modes separately first local control push buttons then central control push buttons In case of a 2 channel transmitter the change from local control to central control should start with controller s memory deletion and only then transmitte r s programming procedure for central mode can start One transmitter can be added during one programming cycle Full memory is signalled with pulsating LED red diode S A COMFORT MODE TIME PROGRAMMING RADIO TRANSMITTERS DELETION Press PROG push button of SRP 02 device for a longe
4. erised with this sign can cooperate with each other Roller blind motor terminals upward movement a downward movement v Z5 Z O Input supply terminals L N WARRANTY CARD Optic signalling of receiver s operation C There is 24 months guarantee on the product ZAMEL provides a two year warranty for its products The ZAMEL warranty does not cover a mechanical defects resulting from transport loading unloading or other circumstances b defects resulting from incorrect installation or operation of ZAMEL products c defects resulting from any changes made by CUS the device is damaged or deformed In case of TOMERS or third parties to products sold or equipment necessary for the correct operation of products sold d defects resulting improper functioning of the device contact the from force majeure or other aleatory events for which ZAMEL is not liable e power supply batteries to be equipped with a device producer in the moment of sale if they appear All complaints in relation to the warranty must be provided by the CUSTOMER in writing to the retailer after discovering a defect N ZAMEL will review complaints in accordance with existing regulations The symbol means selective The way a complaint is settled e g replacement of the product repair or refund is left to the discretion of ZAMEL collecting of electrical and electronic Guarantee does not exclude does not limit nor does
5. in backlight elements Ambient temperature range 10 55 C Operating position free Casing mounting installation cable box 60 mm Casing protection degree IP20 EN 60529 Protection level II Overvoltage category II Pollution degree 2 Surge voltage 1 kV EN 61000 4 5 Dimensions 47 5 x 47 5 x 20 mm Weight 0 039 kg Reference standard EN 60669 EN 60950 EN 61000 I The device is designed for APPEARANCE PERO single phase installation and must be installed in accord ance with standards valid in a particular country The device should be connected accord CAUTION ing to the details included in this operating manual Installation connection and control should be carried out by a qualified electrician staff who act in accordance with the service manual and the device functions 9 In case of casing dismantling an electric shock may occur and the guarantee is lost then Be fore installation make sure the connection ca bles are not under voltage The cruciform head screwdriver 3 5 mm should be used to instal the D device Improper transport storage and use of the device influence its wrong functioning It is not advisable to instal the device in the fol lowing cases if any device part is missing or P 256 8 YZZ Local wired control terminals upward movement a downward movement v The ZAMEL company devices which are charact
6. lar receiver RCR 01 Radio motion sensor RXM 01 RS 485 EXTA FREE Transceiver A ANT 01 External antenna RTN 01 Retransmitter
7. mber of transmitters 32 roller blind Each of the Range up to 250 m in the open area controllers is operated by means of a wireless P 256 8 remote control The remote control can also control operation of RDP 01 radio dimmer switch on switch off control and light sources brightening dimming and of RWL 01 radio lighting switch Nominal power consumption 0 4 W stand by mode 0 7 W roller blind movement Transmission radio 868 32 MHz Coding way unidirectional Roller blinds control system realised by means of SRP 02 roller blinds Maximum time of roller blind movement 120 sec Comfort mode time adjustment 1 120 sec every 0 1 sec Optic signalling of transmitter s operation LED red diode Local control terminals LOCAL 4 up down Roller blind motor power supply terminals 4 up down Relay contact parameters 2NO 5 A 250 V AC1 1250 VA voltage contacts Number of terminal clamps 6 Section of connecting cables 0 2 2 50 mm used in wired and wireless control of roller blind sunblind and gate drives electric motors of 230 V AC wired local control inputs easily installed in 60 mm junction box energy saving device possibility of con stant work two comfort modes upper and bottom memory of roller blind height level e g roller blind open at a half height level possibility of cooperation with any roller blind switch which is not equipped
8. n first signal pulsates next the signal is constant Press PROG push button of SRP 02 device If the roller blind is in a required comfort position press PROG push button and release it the roller blind stops ROLLER BLIND MOVEMENT TIME IS ADDED next release PROG push button the roller blind moves automatically Time programming example for upper comfort mode In order to programme time for bottom comfort mode it is necessary to close the roller blind completely before programming procedure starts Maximum time is 120 seconds Wait again for about 5 seconds till LED red diode switches on first signal pulsates next the signal is constant RNK 02 2 channel button radio transmitter RNL 01 Radio foot transmitter ROP 01 1 channel radio receiver RWL 01 Radio lighting switch RNK 04 4 channel button radio transmitter RTI 01 IR EXTA FREE transceiver ROP 02 2 channel radio receiver RWG 01 Remote control socket P 256 8 8 channel remote control P 257 4 4 channel remote control RNM 10 4 channel radio modular transmitter RNP 01 4 channel radio transmitter RDP 01 1 channel radio dimmer ROB 01 12 24V Radio gate controller SRP 02 Radio roller blinds controller SRP 03 Central radio roller blinds controller P 257 2 2 channel remote control RNP 02 4 channel radio transmitter ROM 01 1 channel radio modular receiver ROM 10 2 channel radio modu
9. r time After 5 seconds LED red diode switches on Release the push button in SRP 02 signal pulsates and then it switches off MEMORY IS DELETED COOPERATION AND OPERATING RANGE SRP 02 RNK 02 RNK 04 P 256 8 P 257 4 2 RNM 10 RNP 01 RNP 02 RNL 01 RTN 01 RCR 01 RTI 01 1 channel transmitters do not cooperate with roller blind controllers CAUTION The given range concerns open area an ideal condition without any natural or artificial obstacles If there are some obstacles between a transmitter and a receiver it is advisable to decrease the range according to wood and plaster from 5 to 20 bricks from 10 to 40 reinforced concrete from 40 to 80 metal from 90 to 100 glass from 10 to 20 Over and underground medium and high electrical power lines radio and television transmitters GSM transmitters set close to a device system have also a negative influence on the range RANGE LOSS CONCERNING RADIO SIGNALS GOING THROUGH OBSTACLES S A Ra RS bricks from 10 to 40 wood and plaster from 5 to 20 reinforced concrete from 40 to 80 metal from 90 to 100 glass from 10 to 20 TRANSMITTERS RECEIVERS k Open the roller blind Press PROG push button of SRP 02 device for a longer time until completely LED red diode switches on constant signal Next release PROG push button Wait for about 5 seconds till LED red diode switches o