Home
Golvo 7000 7007 Instruction Guide
Contents
1. Before assembly make sure you have the following parts and tools bag containing instruction guide tag marked Emergency lowering charger cable and exten sion cable two M6 screws tools Wrench 17 mm Allen wrench 4 5 and 6 mm A Lock the wheels before you begin assembling the lift Ji Start by unscrewing the transport safety plate metal plate at the lower edge of the mast Then throw away the safety plate the screws and the red information sticker attached to the safety plate A Place the mast on the center beam of the base between the two black plastic caps B Push the mast forward as shown in the illustra tion above until it snaps onto the center beam 2 Secure the mast with two M6 screws enclosed in the upper holes on the mast NOTE Do not place any screws in the lower holes A 3 A Place the armrest unit in the bracket on the mast inserting it into the lower track first B Lower the armrest unit pressing on it until it snaps onto the upper track Note that none of the premounted M8 screws should be completely un screwed although you may need to loosen some of them Golvo 7EN140102 03 5 4 Secure the armrest by tightening the two pre mounted M8 screws www liko com S 5 Assemble the sling bar or other accessory using M8 6 Connect the cables to the control box as follows
2. 3 Check that the charger cable is correctly connected pages 6 amp 11 4 Check that the contact plates of the bat tery are not defective or broken off 5 If the lift still does not work satisfactory contact Liko 1 Check that the emergency stop button Check that the emergency stop button is not pushed in page 8 2 Use the electrical emergency lowering to safely lower the patient see page 8 3 Use the mechanical emergency lowering to safely lower the patient page 8 4 Check that the battery is charged page 11 5 If the lift still does not work satisfactory contact Liko The lift stops in the elevated position Check that the correct lifting range has The lift does not reach its maximum gt been set page 9 lifting height If the lift still does not work satisfactory contact Liko If you hear unusual sounds or discover gt Contact Liko wear and tear on the strap Golvo 7EN140102 03 15 www liko com Care and Maintenance Care and inspection For safe and troublefree operation a few routine procedures should be performed every day the lift is used Visually inspect the lift and check for external damage or wear Check the sling bar connector Check the lift strap for wear and make sure it is not twisted Check that the safety latches work properly Test the operation of raising and lowering and the base width adjustment function Check th
3. F screws and locking nut enclosed Make certain to Cable for hand control to socket number 1 turn the screws 2 mm 0 08 inch past the lock func Cable for lift motor to socket number 2 tion on the nut Do not tighten so much that the sling Cable for base motor to socket number 3 bar connector cannot move in relation to the locking plate J 7 A Connect the extension cable for the charger 8 Place the battery in its holder above the control cable to the control box box Check that the battery locks into the holder B Insert it in the tension clip on the underside audible click of the control box C Finally connect the charger cable to the extension cable 9 Mount the holder for the 10 Reset the emergency stop 11 Press the tag marked Emer charger cable Hook it on the by turning the button in the gency securely into place on the outer edge and press down direction indicated by the arrows emergency lowering device until you hear a click ES After assembly check to ensure that the lifting motions correspond with the buttons on wheel brakes work properly the handcontrol the width adjustment of the base works properly the emergency lowering works properly the indicator lamps on the front of the control box mechanical and electrical light during charging e a Golvo 7EN140102 03 6 www liko com Disass
4. Max 300 kg 660 Ibs ED Universal SlingBar 450 Prod No 3156075 R Standard for Viking L eS Max 300 kg 660 Ibs Universal SlingBar 600 Prod No 3156076 Max 300 kg 660 Ibs Universal TwinBar 670 Prod No 3156077 Max 300 kg 660 Ibs Sling SideBars 450 Prod No 3156079 incl storage bag Max 300 kg 660 Ibs Sling Cross bar 450 Prod No 3156021 Max 300 kg 660 Ibs Sling Cross bar 670 Prod No 3156018 Max 300 kg 660 Ibs gt Golvo 7EN140102 03 12 www liko com SlingBar Cover Paddy 30 Prod No 3607001 fits Universal SlingBar 350 450 and 600 and SlingBar Slim 350 Bag for SlingBars Prod No 2001025 Golvo 7007 LowBase Kit Prod No 20090071 This reconstruction kit enables the lift to be adapted to beds barrack beds with a very low ground clearance 58 110 mm 2 28 4 3 inch Contact Liko for more informtion Quick release Hook Liko s Quick release Hook system enables quick and easy exchange of lifting accessories on Liko s mobile and stationary lifts Golvo requires Q link for use with Quick release Hook Quick release Hook Universal fits Universal SlingBar 350 450 and 600 Prod No 3156074 3156076 Quick release Hook TDM fits Sling Cross bar 450 and 670 Prod No 3156021 and 3156018 and Universal TwinBar 670 Prod No 3156077 When a sling bar mounted with the Quick release Hook system is used the lifting height will be 33 mm 1 3 inch shorter than with a permanently mo
5. A B B B2 B G D E F G H H4 Ho Weight Turning diameter load Max Max Min diameter Golvo 7000 ES 75 75 200 1750 1990 1340 540 1120 670 950 530 810 960 840 600 110 23 42 1240 Golvo 7007 ES 75 75 200 1850 2080 1440 580 1190 750 1020 620 900 1060 940 600 110 23 44 1330 Golvo 7007 46 75 200 1850 2080 1440 580 1190 590 600 750 1020 620 900 1060 940 600 110 20 60 46 1330 LowBase 7 E Lifting range 1260 mm is adjustable See page 9 Maximum load and weight in Ibs Measurement in inches Model Wheel Max L A A B By Bog B3 C D E F G H H4 Ho Weight Turning diameter load Max Max Min diameter Golvo 7000 ES 2 96 2 96 440 69 78 53 21 44 26 38 21 32 38 33 24 43 1 93 49 Golvo 7007 ES 2 96 2 96 440 73 82 57 23 47 30 40 24 35 42 37 24 43 1 97 52 Golvo 7007 1 8 2 96 440 73 82 57 23 47 23 2 23 6 30 40 24 35 42 37 24 43 0 8 24 101 52 LowBase SSRS i j 7 Lifting range 49 6 inches is adjustable See page 9 Golvo 7EN140102 03 www liko com Assembly mast with lift arm motor for lift arm control box and sling bar with bolt and locking nut M8 armrest base including motor for base width adjustment battery box including holder for charger cable Re hand control with cable
6. Liko reserves the right to change aspects of the products without prior notice Contact your local Liko representative for updated information and advice Design and Quality by Liko in Sweden Liko is quality certified according to ISO 9001 and its equivalence for the medical device industry ISO 13485 Liko is also certified according to environmental standard ISO 14001 i4 Liko A GITE Company www liko com Manufacturer Liko AB SE 975 92 Lulea Sweden info liko se Copyright Liko AB 2009 07
7. Short max 70 kg 154 Ibs pair Short max 100 kg 220 Ibs pair For more information see instruction guide for Liko MasterVest mod 60 64 or Liko Lift Pants mod 92 Prod No 3166511 Prod No 3166512 Leg Protector Leg Protector Set Golvo 7000 grey Leg Protector Set Golvo 7007 grey Extra Battery Box Prod No 2006106 Charger for Extra Battery Prod No 2004106 for wall mounting or for use with Table Charger Housing Table Charger Housing Prod No 2107103 excl battery box and charger a table charger housing for the charger when you do not wish to mount the charger on the wall Golvo 7EN140102 03 14 Prod No 3156513 E desig cc Na P Mahy cc b Prod No 2006011G Prod No 2006012G www liko com Simple Troubleshooting Check that the emergency stop button is not pushed in page 8 2 Check that the cables to the control box are correctly connected page 6 3 Check that the charger cable is not connected to the power socket 4 Check that the battery is charged page 11 5 Check that the contact plates of the battery are not defective or broken off 6 If the lift still does not work satisfactory contact Liko The lift does not work up down gt Base width adjustment does not work Battery charging does not work is not pushed in page 8 2 Check to ensure that the power socket is power supplied
8. the sling bar closer to the floor you can do this by using the mechanical lowering device to extend the lift strap Do not extend the lift strap more than necessary since this also influences the maximum lifting height For example when lifting a patient from the floor it may be necessary to lower the lifting range if the sling s strap loops do not reach the hooks of the sling bar even when the lift arm is in its lowest position Do the following Hold down the red emergency lower ing handle while simultaneously pulling down the sling bar with the other hand This extends the lift strap and lowers the sling bar Continue until you achieve the needed length After mechanical lowering Resetting the lifting range If you extend the lift strap while testing using the emer gency lowering function the height of the lifting range is lowered To reset the maximum lifting height you must re establish the original length of the lift strap Do the following 1 Unweight the lift strap above the emergency lower ing device by placing the sling bar on the lift mast or by having another person holding up the sling bar to keep the lift strap slack 2 Move the emergency lowering handle down and up with one hand while turning the black knob clockwise tightening the lift strap with your other hand Repeat the action until the red mark on the lift strap is slightly above the emergency lowering device Armrest If needed the armrests can
9. at the correct lifting range has been set and that the emergency lowering works properly Charge the battery every day the lift is being used and check the charger function When necessary clean the lift with a moist cloth using common surface cleaners or disinfectants NOTE Do not use cleaning products that contain phenol or chlorine since these can eventually damage aluminum and polyamide material A The lift must not be exposed to running water Service Golvo must be inspected at least once per year Pay particular attention to parts that are subject to wear A Repairs and maintenance may only be carried out according to Liko service manual by personnel authorized by Liko and using original Liko spare parts Service agreements Liko invites you to sign a service agreement for regular maintenance and testing of your Liko products Contact your local Liko representative for more information Transportation and storage During transportation or when the patient lift is not to be used for some time the emergency stop button should be pushed in The environment where the patient lift is transported and stored should have a temperature between 10 C and 40 C and a humidity between 30 and 75 The air pressure should be between 700 and 1060 hPa Recycling For instructions on how your Liko product should be recycled please visit our website www liko com Product changes Liko s products are constantly being updated and refined
10. attery must be re charged imme diately A 7 Alternative charging procedures Alt A With built in charger With wallmounted charger or table charger housing Plug the charger cable into a power Loosen the holder for the charger cable Remove the battery box from the socket 100 240 V AC Check that control box by loosening the locking device on top of the battery box the yellow lamp on the control box Alt A Place the battery box on the wallmounted charger Check that the lights indicates charging charger is plugged into the power socket 100 240 V AC and that the If the charger cable is stretched out yellow lamp on the front of the charger lights indicates charging it should be replaced to avoid the Alt B Place the battery box on the charger in the table charger housing risk of the cable getting caught and Check that the charger is plugged into the power socket 100 240 V AC tear and that the yellow lamp on the front of the charger lights indicates char ging Note The lift does not operate when the charger cable is plugged into a power socket Old batteries are to be left at the nearest recycling station or given to personnel authorized by Liko Golvo 7EN140102 03 11 www liko com Maximum Load Different maximum allowable loads may apply to different products on the assembled lift system lift sling bar sling and other accessories For t
11. be folded down into a sup port position The armrests have two functions to give the patient a greater sense of security and to make it easier for the caregiver to move the lift A CAUTION When moving a patient in the lift between different rooms the armrests should be placed in the support position Golvo 7EN140102 03 9 www liko com Parking the sling bar When the lift is not being used or when moving an empty lift the sling bar can be placed in the parking bracket The parking bracket is intended for use with Universal SlingBar 350 450 and 600 all models A Important when using the parking position Never raise the lift arm while the sling bar is parked in the parking bracket since this might cause personal injury or damage on the lift if the sling bar suddenly releases from the hook and swings forward Transfers from a bed Always make certain that the lift strap is vertical and parallel to the mast To achieve this Golvo should be placed correctly under the bed Adjust the width and or change the position of Golvo in relation to the base of the bed to achieve the correct position UN Golvo 7EN140102 03 Check that the lift strap is vertical during the lift Do not start the lift unless the sling bar is well balanced An unbalanced load leads to wear and tear on the lift strap It may also ca
12. cy room use and horizontal lifting etc In this document the person being lifted is called the patient and the person helping is called the caregiver A are triangles used to warn of situations that demand extra care and attention li IMPORTANT Carefully read these instructions and the instructions for the particular lifting accessory being used Lifting and transferring patients always presents a potential risk It is essential to thoroughly understand the content of these manuals and that only trained persons use the equipment If you have questions please contact Liko or your local Liko representative Table of Contents Safety Instructions ssssssssssseeneeenene mener nennen 2 BI 3 Technical Data iore en der e tot e e erar De tanks 3 Measurements sirasini ornk paniei naani iaaii eaaa anaiai ania i aaa 4 ntium 5 6 Disassemibly ms ur cte ee eA Decret e lice ER Dre cd a e UI Dv uu 7 eire E 8 10 Transfers from Bed nein ehe Rae nu EE RN Enna AR ER ERE RR ERN E 10 Charging the Batteries 2 eon Ideen er ee tene cec d eed i te a 11 Maxim m B er o e 12 Recommended Lifting Accessories esseeene 12 14 Simple Troubleshooting s cte de tele otc erede Deeds 15 Care and Maintenance sssssssssssssseeeeeeenrennen enne 16 A NOTE This instruction guide contains information that is important for users of the product A complete under stan
13. ding of the contents of the instruction guide is essential and only personnel who are well informed should use the equipment Remember to keep the instruction guide readily accessible for users of the product Safety Instructions Before using the lift for the first time make certain that the lift is assembled according to the instructions the lifting equipment is correctly applied to the lift the batteries have been charged for at least 6 hours you have read the instruction guides for the lift and lifting accessories personnel using the equipment have received appropriate instructions and training Before lifting always make certain that the lift strap is not twisted or worn and that it can move freely in and out of the lift unit you have selected the correct type size material and design of slings and accessories to safely meet the patient s needs lifting accessories are not damaged the lifting accessory is correctly applied to the lifting equipment the lifting accessory is correctly and securely applied to the patient so that no personal injury can occur the sling s strap loops are correctly fastened to the slingbar hooks when the sling strap is extended but before the patient is lifted from the underlying surface A Never leave a patient unattended in a lifting situation C Golvo 7000 ES 7007 ES 7007 LowBase are tested by an accredited testing institute and comply with the require ments of t
14. ed lead acid gel type batteries New batteries are available from supplier Battery Built in charger for 100 240 V AC charger 50 60 Hz max 400 mA Lift motor 24 V 6 5 A Manufactured by Liko with planetary gearing and safety nut pre vents excessive wear Motor for width adjustment 24 V 3 5 A Geared motor Wheels Standard front 75 mm twin wheels Standard rear 75 mm lockable twin wheels Material Anodized aluminium Golvo 7EN140102 03 9 Emergency lowering Mechanical and electrical Intermittent Int Op 10 90 active operation max operation 2 min Out of a time of 100 active must be less than 10 however not more than 2 min Degree of protection IP 43 Sound level 53 dB 3 El This device is built for indoor operation Type B according to the degree of protection against electric shock Class II equipment Patented www liko com Golvo 7000 ES 7007 ES Measurements r Se Y L L l m TEe T H T 0 Golvo 7007 LowBase 7 By Sa Fi 1 A J Maximum load and weight in kg Measurement in mm Model Wheel Max L A
15. embly 1 Start by loosening the sling bar or other accessory mounted on the lift 2 Loosen the armrest holder as described below Ke A Loosen both of the M8 screws on each side of the B Remove the armrest holder by using two screw mast drivers 3 Release cables for the hand control the lift motor and the motor for base adjustment 4 Remove the mast A When the mast is free from the base it must be supported so it does not fall A Remove both of the safety screws from the upper B Screw in the safety screws in the lower holes on holes on the mast the mast This releases the mast from the base and it can now be taken down Golvo 7EN140102 03 7 www liko com Operation Se x Golvo 7EN140102 03 Operation Operate the lift using the pushbuttons on the hand control For raising and lowering press either of the two upper pushbuttons The direction in which the arrows are point ing applies when the hand control is held as shown in the illustration The thicker sets of arrows refer to the maximum lifting speed The thinner arrows refer to the lower lifting speed The lifting motion ends as soon as the push button is released For base width adjustment press either of the two lower push buttons U Wider f Narrower Emergency stop To activate Press in the red button on the control box To reset Turn the butto
16. he directives for medical technical Class 1 products MDD 93 42 EEC Golvo 7000 ES 7007 ES 7007 LowBase comply with the requirements according to IEC 60601 1 IEC 60601 1 2 EN ISO 10535 UL 60601 1 and CAN CSA C22 2 No 606 1 Particular care must be taken when using strong sources of electromagnetic interference such as diathermy etc so that cables are not positioned on or near the lift If you have questions please consult the responsible assis tive device technician or the supplier This equipment is not suitable for use in the presence of flammable mixtures Maximum load 200 kg 440 Ibs Golvo 7EN140102 03 2 www liko com Definitions Golvo 7000 ES 7007 ES Rear wheel with brake Motor for base width adjustment 1 Lift strap 2 Sling bar with safety latches 3 Parking bracket for sling bar 4 Foldable armrest 5 Mast with built in motor for lifting 6 Base 7 Front wheel 8 9 10 11 12 13 14 15 16 Golvo 7007 LowBase Control box with emergency stop built in charger and electrical emergency lowering raising Battery box Hand control Manoeuvering handles Emergency lowering mechanical Product decal Lift arm Technical Data Lifting speed Two speed levels 4 8 cm s 1 9 inch s and 3 2 cm s 1 3 inch s both speed levels without load Batteries Two 2 9 Ah 12 V valve regulat
17. he total lift system the lowest max allowable load indicated for the respective products on the system always applies For example A Golvo that is approved for 200 kg 440 Ibs may be equipped with a lifting accessory that is approved for 300 kg 660 Ibs In this case the applicable max load is 200 kg 440 Ibs for the total lift system Study markings on the lift and lifting accessories or contact your Liko representative if you have any questions Recommended Lifting Accessories A Using other lifting accessories than those recommended below may induce risk Sling bars and accessories recommended for use with Golvo are described below Changing sling bars and adding extra accessories affects the maximum lifting height of the lift Before changing sling bars and accessories it is important to ensure that it will still be possible to achieve the desired lifting height for situations in which the lift will be used For choice of appropriate slings and other lifting accessories see e g the brochure Lifting accessories For further guidance on choosing a sling consult the instruction guide for the respective sling model Here you will find advice on suitable combinations of Liko sling bars and Liko slings Contact your Liko representative or visit www liko com for advice and information on Liko s product range SlingBar Mini 220 Prod No 3156005 8 Max 205 kg 450 Ibs i Universal SlingBar 350 Prod No 3156074 B
18. iA Liko A Cr Company Golvo 7000 ES 7007 ES Golvo Instruction Guide English 7EN140102 03 2009 07 03 Applies to the following models Golvo 7000 ES Prod No 2000009 Golvo 7007 ES Prod No 2000010 Golvo 7007 LowBase Prod No 2000061 Golvo 7007 LowBase Product Description Golvo is an electrically powered mobile lift i e both raising and lowering of the lift arm and width adjust ment of the base are done with electric motors To ensure maximum safety for caregivers and patients Golvo is equipped for both mechanical and electrical emergency lowering All Golvo lifts are equipped with convenient armrests to assist both the caregiver and the patient If needed the armrests can be folded down into a support position Golvo is also available in a design with an extra low base Golvo LowBase This model is recommended for lifting to and from beds barrack beds that have a ground clearance of 58 110 mm 2 28 4 3 inch Golvo can be used in most lifting situations for example between bed wheelchair to from the toilet in bath and shower to from the floor for weighing patients and for horizontal lifting A comprehensive range of accessories are available for Golvo including sling bars of different widths slings in many sizes and fabrics and accessories for ambulation gait training static weight bearing weighing patients and for emergen
19. n in the direction of the arrows Electrical emergency lowering raising For electrical emergency lowering raising use a thin object and press into the hole marked Emergency on the control box A The object used to press must not be too sharp since this might cause damage to the control box Mechanical emergency lowering 1 Emergency lowering should always take place over a bed wheelchair or other appropriate place 2 To operate pull down the handle marked Emergency Lowering and then release the handle upward Continue pumping the handle until the patient in the lift is on a stable surface Press down on the sling bar and continue to pump the handle down and up until the sling bar is low enough to permit the sling s strap loops to be unhooked Locking the wheels The rear wheels can be locked for rotation and lateral movement To lock the wheels press down the brake lever with your foot To release the brakes press up the brake lever with your foot During lifting wheels should remain unlocked so that the lift may shift to the patient s center of gravity The wheels should however be locked if there is a risk for the lift mov ing into the patient for example when lifting from the floor A Locked wheels during lifting increases the risk of the lift tilting over A CAUTION Due to the risk for injury never use your hands to lock the foot brake 8 www liko com Setting the lifting range If you need to move
20. unted sling bar See Guide to Liko s Quick release Hook System which can be downloaded from our website www liko com or contact Liko for more information on the advantages and use of the Quick release Hook system Standaid Set Prod No 2001020 For patients with sufficient body stability the Standaid Set can be used for shorter transfers for example between a wheel chair and a toilet or between a bed and a wheelchair The patient is lifted to a semi standing position with the help of SafetyVest or the SupportVest behind the back and under the arms Stretchers Most Liko stretcher models can be used in combination with Golvo Contact Liko for more information Golvo 7EN140102 03 13 Quick release Hook Prod No 3156508 Univers al wW Q link Prod No 3156509 Quick release Hook TDM Prod No 3156502 Liko OctoStretch Prod No 3156055 www liko com Scale In need of weighing patients in combination with Golvo we recommend LikoScale 350 Max load 350 kg 770 Ibs LikoScale 350 is certified according to the european directive NAWI 90 384 Non Automatic Weighing Instruments Contact Liko for more information Support Springs Elastic springs enable a gentler springing motion which makes activities such as gait training easier and more natural Springs are available in three different designs Long max 70 kg 154 Ibs pair
21. use instability of the lift during the lift motion A An unbalanced load increases the risk of the lift tilting over 10 www liko com Charging the batteries For maximum battery life batteries must be charged regularly We recommend charging after use or each night Maximum charge is reached after about 6 hours When the batteries are fully charged the charger disconnects automatically NOTE A yellow indicator lamp on the control unit lights constantly during charging When the batteries are fully charged the yellow lamp shuts off If this lamp continues to light after 8 hours the batte ries probably need to be replaced Discontinue charging and replace batteries Never charge batteries in a wet area If the lift is not in daily use we recommend that the emergency stop be pressed in after the lift has been used This breaks the current and conserves battery power Make sure the lift is fully charged before pressing in the emergency stop Battery capacity a If the battery needs charging a beep tone will sound and a lamp A is lit on the handcontrol There is howe ver enough power left in the battery for a few more lifts 0 25 50 75 CAPACITY O 25 50 75 100 CAPACITY A display on the control box shows the current battery capacity When all fields of the display are black the A battery is fully charged When a plug symbol appears Oliko see illustration the b