GE Monogram® Installation Instructions 36" Island Vent
Contents
1. 15 Model Available Required Accessory Recirculating Operation Product Dimensions Design Information Model This vent hood is designed to ZV850 be used in vented ceiling mounted installations ZX858 For 8 ft ceiling height This kit includes decorative duct covers and support frames to reach an 8 ft ceiling height ZX859 For 9 ft ceiling height This kit includes decorative duct covers and support frames to reach an 9 ft ceiling height This hood may be installed for recirculating operation One of the following kits is required and must be ordered with the hood ZXR858 For 8 ft ceiling height ZXR859 For 9 ft ceiling height ZXR8510 For 10 ft ceiling height The vent hood must be installed 24 min and 30 max above the cooking surface 25 1 2 is recommended for best venting performance and to insure that the duct cover meets the ceiling The cooking surface should be at least 36 above the floor Installation will be easier if the vent hood is installed before the cooktop and countertop is installed n 000 0000 I 25 1 2 Recommended 36 Reference 36 Island Vent Hood NOTE Accessories to meet proper ceiling height are required to complete the installation ZX8510 For 10 ft ceiling height This kit includes decorative duct covers and support frames to reach a 10 ft ceiling height Order t
2. e Observe the recommended 25 1 2 space between the cooking surface and bottom of hood Approx 1 1 2 Beyond Cooking Cooktop Surface E e o Countertop Side View 8 3 4 Top View of Support Framing ol Cross ini Framing n Gelling 8 3 4 7 5 8 Side View Front of Hood Upper Support Typical Support Frame Mounting praes Lower The framing should be spaced 8 3 4 on the sides and 7 5 8 at the front from centerline to centerline to accept mounting screws in the vent support frame Ceiling support structure e At the hood location install 2 x 4 cross framing between ceiling joists as shown e The 2 x 4 cross framing can be installed standing or flat depending on duct run See illustration of ductwork page 8 Note The cross framing must be spaced 8 3 4 on the side from centerline to centerline in order to accept the hood mounting screws Step Advance Planning continued Installation Preparation e Arrange cross framing in the ceiling to suit the existing structure See examples Secure each 2 x 4 block with at least four 4 10 wood screws 3 long minimum size screws not supplied Use 8 wood screws total for the two supports e The cross framing must be accurately aligned to assure correct positioning of the hood e The cross framing must be level in all direction
3. 04306398
4. Note Any home ventilation Rectangular system such as a ventilation to 6 round 2 ft hood may interrupt the proper flow of combustion air and 3 1 4 x 10 4 ft exhaust required by fireplaces 3 1 4 x 12 4ft gas furnaces gas water heaters and other naturally vented systems To minimize the chance of interruption of such naturally 6 round to rectangular transition 90 elbow vented systems follow the heating equipment manufacturer s guidelines and safety standards such as those 3 1 4 x 10 4 ft 3 1 4 x 12 4 ft Rectangular to 6 round transition 90 elbow published by NFPA and ASHRAE Round wall cap with damper 24 ft 3 1 4 x 10 24 ft 3 1 4 x 12 18 ft Rectangular wall cap with damper Round roof cap 33 ft o gi A A 249686 Actual length of straight duct plus duct fitting Total Duct Run equivalent Equivalent length of duct pieces are based on actual tests conducted by GE Evaluation Engineering and reflect requirements for good venting performance with any ventilation hood Installation Preparation 36 Island Vent Hood Plan the location Ceiling Determine the exact location of the vent hood E Hood Step e Use a plumb to check location to be sure i Ducting countertop cooktop location below the hood Veli Centerline Advance will align exactly Planning The hood should project forward 1 1 2 i beyond the front edge of the cooking appliance See illustration
5. be sure the mounting holes will provide parallel alignment with the countertop below e Center punch all hole locations e Drill pilot holes in the 4 screw locations 6 Fronto Nood Use a 5 32 bit and drill approximately g 1 1 2 deep ae ee e Cut the 6 1 4 dia duct opening and approx Wire Access Hole 1 dia wire access hole Hood Mounting Lower Support Flange x 1 se 13 5 8 sppe STTIIIZIZIZI IZIIII I r 5 a Support Frame 39 1 8 Opening 25 1 2 Recommended 75 1 8 Check Level in to Floor Both Direction Lower lt lt i Countertop y Support o dae ee Frame J Y Install upper support frame Note 39 1 8 to top of hood flange can be increased e Secure the upper support frame to the up to 42 max ceiling joists and or cross framing with the 75 1 8 min to floor 77 7 8 max 4 screws provided For maximum rigidity Install lower support frame and strength the screws must be driven PP h fthe ioi d e Insert lower support frame from required Tite a THE Jpistana orco accessory ZX858 ZX859 or ZX8510 into the e o 5 b h f upper support frame and loosely secure with paca i wed support a 8 screws and washers 4 on front and 4 on level vertically and horizontally back sides e Adjust the lower support frame up or down to the desired height above the countertop Tighten screws Important Again check to be sure t
6. studs into the support frame holes and at the same time guide the hood duct connector into the house duct Install 4 nuts and lock washers to the mounting studs Tighten with a 10mm wrench Verify that power is turned off at the source WARNING e Ve If house wiring is not 2 wire with a ground wire a ground must be provided by the installer When house wiring is aluminum be sure to use U L approved anti oxidant compound and aluminum to copper connectors Mounting Installation 36 Island Vent Hood Stop Screw Install 4 lock washer and 4 Nuts e Check hood level in both directions e Check to be sure that the duct is positioned over the hood connector e Seal the duct connection with duct tape Note Do not drive screws through lower duct connection Doing so will prevent proper damper operation e Install strain relief into the knockout of the junction box cover e Insert house wiring through strain relief and tighten e Connect white leads to branch circuit white lead e Connect black leads to branch circuit black lead e Connect green yellow leads to branch circuit green or bare ground lead e Secure all connections with wire nuts on each electrical connector e Push wires into junction box and replace cover Be sure wires are not pinched 13 11 Slide Duct Cover Down Install Side Utility Bars e Hold the decorative duct cover and remove the temp
7. vapors Structural framing installation work and electrical wiring must be done by qualified person s in accordance with all applicable codes and standards including fire rated construction Sufficient air is needed for proper combustion and exhausting of gases through the flue chimney of fuel burning equipment to prevent back drafting Follow the heating equipment manufacturer s guidelines and safety standards such as those published by the National Fire Protection Association NFPA and the American Society for Heating Refrigeration and Air Conditioning Engineers ASHRAE and the local code authorities Local codes vary Installation electrical connections and grounding must comply with applicable codes In the absence of local codes the vent should be installed in accordance with National Electrical Code ANSI NFPA 70 1990 or latest edition Step 3 Check Installation Hardware 9 Step 4 Mount Template 10 Step 5 Install Support Frame 10 Step 6 Secure Wiring cee eeeeeeees 11 Step 7 Size and Install Ductwork 11 Step 8 Install Decorative Duct Covers 12 Step 9 Install Hood eeeeeeeeee 13 Step 10 Connect Electrical 13 Step 11 Slide Duct Cover Down Install Side Utility Bars 14 Step 12 Install Filters eee 15 Step 13 Finalize Installation
8. GE Monogram Installation Instructions 36 Island Vent Hood Model ZV850 Monogram Contents Before you begin Read these instructions completely and carefully IMPORTANT Save these instructions for local inspector s use IMPORTANT OBSERVE ALL GOVERNING CODES AND ORDINANCES Note to Installer Be sure to leave these instructions with the Consumer Note to Consumer Keep these instructions with your Owner s Manual for future reference WARNING This appliance must be properly grounded See Electrical Supply page 5 If you have a question concerning the installation of this product call the GE Answer Center Consumer Information Service at 800 626 2000 24 hours a day 7 days a week If you received a damaged vent hood you should immediately contact your dealer or builder For Monogram local service in your area 1 800 444 1845 For Monogram service in Canada call 1 888 880 3030 For Monogram Parts and Accessories call 1 800 626 2002 CAUTION Due to the weight and size of this vent hood and to reduce the risk of personal injury or damage to the product TWO PEOPLE ARE REQUIRED FOR PROPER INSTALLATION Proper installation is the responsibility of the installer Product failure due to improper installation is not covered under the GE Appliance Warranty See the Owner s Manual for warranty information WARNING To reduce the risk of fire or electrical shock do not use
9. Vent Hood wee Step Top Duct Install Screw on Cover Pretap Each Side 2 Screw Install Holes TTT Bottom Duct Cover Decorative Top Duct Bottom Duct Cover Cover Duct Covers I i o o o Top Duct 0 Cover J T Stop Screw o io Install Stop Screw in One 7 of 3 Holes Sali e Pretap or drive decorative screw into the e Locate the stop screw in the envelope taped screw holes on the support frame This will to the front of the hood Set aside make screw installation easier e Slide the bottom decorative duct over the e Separate the two decorative duct covers installed top duct and push up past the stop e Select the inside top cover which has two screw hole location screw holes in the top e Install the supplied temporary stop screw e Slide the decorative duct cover over the in one of 3 holes in the support frame or support frame and push to the ceiling the top duct cover to prevent the bottom e Attach to the hood support at the top with decorative duct cover from sliding down 2 supplied decorative screws Wee The slop seria be installed Failure to do so could result in personal injury or damage to the duct cover 12 Step Install Hood Step Connect Electrical Align Duct Connector to Align House Duct Studs Note TWO PEOPLE ARE REQUIRED TO COMPLETE THIS INSTALLATION Lift the hood up to the support frame Carefully align the hood mounting
10. ckaging e Remove junction box cover Front of Hood o v 2 D de a pe 0 i e Install strain relief onto junction box cover Locate the hardware accessory box packed with the hood and check contents sh S gt 8 S 3 S ST Remove the Packaging Check Step 2 D wn Es oO Ss Es lt o 3 En os 2 oO OA 4 Hex head wood lag screws 6mm x 2 1 2 2 Le pe B Se O La t A o oO oO frames or 1 4 x 2 1 2 Template hillips Head P Decorative Screws 2 2 Side Bars With 4 Machine Screws a D Q s Q D gt D E i gt 2 D n gt D Pa E 0 1000 00 e800 Set 000000 to the front of the hood to be sure it Do contains one stop screw Leave this screw in the envelope 000000 000000000 00 00900000 3 Filters Mounting Screw Holes Support Frames with 8 Screws and 8 Washers S y 19 0 0 x N D D 0 0 x N oO 10 0 0 x N E n n 5 O S Check contents of the required Decorative Duct Covers Step Mount Template Step Install Support Frame Installation 36 Island Vent Hood e Align the template with the marks on the 9 ceiling and tape in place Be sure the template is oriented correctly with the front of the hood e Use a plumb to
11. he required accessory at the same time as the vent hood and have on site before installation Both the hood and accessory must be on site at the time of installation Follow the installation instructions packed with the accessory to complete the installation Height to Ceiling 26 1 4 for 8 ft Ceiling Using ZX858 Accessory 38 1 8 for 9 ft Ceiling Using ZX859 Accessory 50 1 8 for 10 ft Ceiling Using ZX8510 Accessory The distance between the cooking surface and the bottom of the hood must be at least 24 and up to 30 The 25 1 2 recommended installation height above the standard 36 countertop will insure duct cover fit to the ceiling Design Information 36 Island Vent Hood Usin g Duct A duct cover accessory is required for all Cover Accessories ceiling heights Use this chart to determine the correct Duct Cover Accessory for 8 ft to 10 ft ceilings that must be ordered with the hood ZV850SB Installation Heights ZV850 Duct Cover Dimensions Actual Vented Ceiling Possible Hood Duct Cover Installation Height Installation Height Accessory ZX858SB 14 3 16 15 3 16 ZX859SB 20 1 2 22 1 2 ZX8510SB 26 27 1 2 h 711 24 1 2 ipa a wo a R 8 0 25 1 2 ACCESSORY ZX858SB 81 25 1 2 to 28 1 2 25 1 2 to 29 1 2 Based on 36 countertop height ACCESSORY ZX859SB ACCESSORY ZX8510SB Tools and Ma
12. he support is level in both directions There is no way to level the hood after the hood is secured to the frame Step Secure Wiring Step Size And Install Ductwork Installation Wiring e Route house wiring through the ceiling hole and pull a length to reach the hood junction box approximately 6 below the support e Tape the wire to the front of the frame support to prevent damage during installation and service To Find Required Duct Length e Measure from house duct flange to bottom of support frame Dimension A Add at least 1 to Dim A for duct overlap at the top Subtract 1 3 4 for hood insertion into the bottom of the frame to determine required duct length e Cut the 6 duct to required length Note The bottom of the duct must be external female connection to the top of the hood The bottom end should be flared slightly to facilitate installation of the hood e Install duct up through support frames and attach to house ducting with sheet metal screws e Seal the connection with duct tape 36 Island Vent Hood M Ceiling Front Side Support Frames Tape House Wiring i i ii Ceiling Y iY i House Duct Fax Side l Required ui Duct Duct upport a i Frame Dim A Lano Duct Connection To Hood m PER LDL 131 a Y kd Bottom Support Frame Flange 11 Installation 36 Island
13. ief for junction box cover e Plumb e Center punch Grounding Instructions The grounding conductor must be connected to a ground metal permanent wiring system or an equipment grounding terminal or lead on the hood WARNING Warning The improper li connection of the equipment Ge grounding conductor can result in a risk of electric shock Check with a qualified electrician or service representative if you are in doubt whether the appliance is properly grounded Installation Preparation 36 Island Vent Hood Duct Use this chart to Total fittings ea Te ene omits Equivalent Quantity Equivalent A alri Duct Piece Dimensions Length Used Length for duct runs to outdoors KALI a straight per foot This Hood Must Note Do not exceed length UE OTH maximum permissable 3 1 4 x 10 1 ft CET Rel Mg equivalent lengths straight per foot 3 1 x 10 or length 3 1 4 x 12 Duct Maximum duct length 100 foot for range hoods 90 elbow 12 ft Flexible ducting If flexible metal 45 elbow 7 ft ducting is used all the equivalent feet 3 1 4 x 10 14 ft values in the table 3 1 4 x 12 10 ft should be doubled 90 elbow The flexible metal 3 1 4 x 10 8 ft duct should be 3 1 4 x 12 6 ft straight and smooth 45 elbow and extended as 3 1 4 x 10 33 ft much as possible 3 1 4 x 12 24 ft Do NOT use flexible 20 ar EBON plastic ducting 6 round to rectangular 2 ft
14. orary stop screw Return the screw to the service manual envelope for future use e Slide the lower duct cover down onto the hood Installation 36 Island Vent Hood e Install the side utility bars with screws as shown Installation 36 Island Vent Hood 12 Install Filter Lower Filter alters Sak e Remove protective film on filters e Tip the filter into the lower slots at the rear of the opening Lift the filter and pull the knob forward until the filter rests on the slots To remove the filters grasp the knob push the filter towards the rear and tilt downwards amp e Remove the protective film covering the Step control panel on the front face of the hood and any other packaging materials e Check all 4 lamps to assure tightness in Finalize sockets Installation e Refer to the Owner s Manual for operating instructions 15 Monogram GE Consumer amp Industrial GE Appliances General Electric Company Louisville KY 40225 monogram com 2007 GE Company NOTE While performing installations described in this book safety glasses or goggles should be worn For Monogram local service in your area call 1 800 444 1845 NOTE Product improvement is a continuing endeavor at General Electric Therefore materials appearance and specifications are subject to change without notice Pub No 49 8970 2 04 07 JR Printed in Italy
15. s Check with a spirit level and adjust if necessary IMPORTANT The ceiling structure must be capable of supporting the weight of the hood approximately 100 pounds and any inadvertent user contact loads It is recommended that the hood support frame be supported by a minimum of 2 x 4 cross framing Ductwork e Use the shortest and straightest duct route possible For satisfactory performance duct run should not exceed 100 feet equivalent length for any duct configuration e Refer to Duct Fittings chart to compute the maximum permissible length for duct runs to the outdoors e This vent hood must use 6 round duct The 6 round duct can transition to 3 1 4 x 10 or 3 1 4 x 12 e Install the house ductwork to run horizontally between ceiling joists or straight up through the roof Finish the Ceiling Finish the ceiling surface Be sure to mark location of the ceiling joists and cross framing Check to be sure that ceiling is level use shims if necessary 36 Island Vent Hood Cross Framing Support Frame Upper Half A Of Support Opening Frame Height Adjustment Slot rage i Ceiling Joint Vent Straight Up Through The Ceiling 6 Round Duct Elbow Flat Standing 0 Vent Between Ceiling Joists Installation 36 Island Vent Hood required accessory ZX858 ZX859 or ZX8510 e Remove the frame cover parts box side bars The vent hood is packed separately from the Step and pa
16. terials Required not supplied Power Supply Installation Preparation Tape measure e Knife e Spirit level e Wire cutter Wire stripper e Wire nuts e Electric drill and 5 32 bit e Phillips screwdriver e Flat blade screwdriver e Hammer e Pliers e 10 mm Hex wrench socket e Safety glasses e Tape to mount template Gloves to protect against sharp edges IMPORTANT Please read carefully CI FOR PERSONAL SAFETY THIS APPLIANCE MUST BE PROPERLY GROUNDED r Remove house fuse or open circuit breaker before beginning installation Do not use an extension cord or adapter plug with this appliance Follow National Electrical Code or prevailing local codes and ordinances Electrical supply This vent hood must be supplied with 120V 60Hz and connected to an individual properly grounded branch circuit and protected by a 15 or 20 amp circuit breaker or time delay fuse e Wiring must be 2 wire with ground e If the electrical supply does not meet the above requirements call a licensed electrician before proceeding e Route house wiring in the ceiling as close to the installation location as possible Allow an additional 3 feet length from ceiling joists to reach the junction box on the hood e Connect the wiring to the house wiring in accordance with local codes 36 Island Vent Hood e 120V 60Hz 15 or 20 Amp 2 wire with ground Properly grounded branch circuit e Strain rel
17. this hood with any external solid state speed control device Any such alteration from original factory wiring could result in damage to the unit and or create an electrical safety hazard To reduce the risk of fire and to properly exhaust air be sure to duct air outdoors Do not vent exhaust air into spaces within walls or ceilings or into attics crawl spaces or garages WARNING TO REDUCE THE RISK OF FIRE USE ONLY METAL DUCTWORK Model Available 3 Required ACCESSOry in 3 Recirculating Operation eeeeeeeeee 3 Product Dimensions i 3 Using Duct Cover Accessories 4 Installation Preparation Tools and Materials Required 5 Power Supply iniziai ie 5 DuctFittinos ruaiuaia iii 6 Step 1 Advance Planning n 7 8 Installation Step 2 Remove the Packaging 9 TO REDUCE THE RISK OF FIRE ELECTRICAL SHOCK OR INJURY TO PERSONS OBSERVE THE FOLLOWING A Use this unit only in the manner intended by the manufacturer If you have any questions contact the manufacturer B Before servicing or cleaning unit switch power off at the service panel and lock service panel to prevent power from being switched on accidentally If the service panel cannot be locked fasten a tag or prominent warning label to the panel For general ventilating use only Do not use to exhaust hazardous or explosive materials or