1. absorption based sensor that is connected to the gas control thermostat see Figure 31 When exposed to flammable vapors it will trigger the control to stop the flow of gas and enter the FVS lockout state While in the FVS lockout state the LED on the control will flash the gas lockout code Refer to the Gas Control Led Status Codes section for an explanation of the codes applicable to the control installed on your water heater If an FVS lockout occurs check around the water heater for sources of chemical contamination such as flammable vapors including gas vapors solvents paint and thinners as well as sources of water and detergents Note Resetting the heater will reset the FVIR circuit if all sources of contamination have been removed and the sensor clears If all sources of contamination have been removed and the system will not reset the sensor will need to be replaced If there is a problem with the wiring of the flammable vapor sensor or the flammable vapor interface the LED will flash the failure status code see Troubleshooting Guide ROTATE LEFT CCW TO REMOVE RSS G FT MOUNTING BRACKET FLAMMABLE VAPOR SENSOR PULL TO REMOVE Figure 31 27 CLEANING THE COMBUSTION CHAMBER 1 Follow procedure outlined in Removing Inner Door Manifold Burner Assembly 2 Use a vacuum cleaner shop vac to remove all loose debris in the combustion chamber 3 Reassemble following the procedure under
2. The tip end of the burner manifold MUST be placed in the upper slotted portion for models with input rate of 40 000 to 50 000 Btu hr to obtain proper installation The tip end of the burner manifold MUST be placed in the lower slotted portion for models with input rate of 60 000 to 75 000 Btu hr to obtain proper installation 2 After confirming no materials of any type are between door gasket and combustion chamber shield align the screws on the inner door with the screw holes on the combustion chamber and tighten with 1 4 nutdriver or 1 4 socket amp ratchet see Figure 15 After tightening the inner door screws visually inspect area around door gasket and skirt for spaces or gaps The door gasket MUST be sealed completely in order for the water heater to perform properly DO NOT OPERATE THE WATER HEATER IF THE DOOR GASKET DOES NOT CREATE A SEAL BETWEEN MANIFOLD DOOR AND COMBUSTION CHAMBER Reconnect the manifold tube to the gas control valve thermostat Note Do Not apply any thread sealant at this connection To prevent any cross threading the manifold tube should be started by hand turn clockwise for natural gas counter clockwise for L P Upon tightening with the fingers and confirming it has not been cross threaded tighten nut with an 3 4 open end wrench see Figure 15 Reconnect all the electrical connections to the bottom of the gas control valve thermostat gently pushing each connector up until it snaps
3. This is a surface treatment and often requires repeated trials in heavily infected systems The chlorination of a system requires that you follow each step explicitly to avoid an untreated portion of the piping system from re infecting another part See the Chlorination Procedure section Longer lasting solutions include chlorination or aeration of the water supply NOTES Since rusty water is caused by a bacteria presence and is not caused by the water heater any treatment would not be considered warranty related 32 CHLORINATION PROCEDURE CAUSES The chlorination procedure is used to eliminate various bacteria that accumulate and grow in water heaters These bacteria often cause odorous or discolored water conditions TREATMENT The simplest treatment available is the shock chlorination of the system This is a surface treatment and often requires repeated trials in heavily infected systems The chlorination of a system requires that you follow each step explicitly to avoid an untreated portion of the piping system from re infecting another part Longer lasting solutions include chlorination or aeration of the water supply PROCEDURE Please read the steps of the chlorination procedure prior to beginning If you feel uncomfortable performing any of these steps contact a service person to perform this procedure for you STEP 1 Turn off the gas and electric supply to the tank STEP 2 Turn off the cold water supply valve to the tank
4. C One gallon of 120 F 49 C water weighs approximately 8 25 pounds Pounds X 45359 Kilogram Gallons X 3 7854 Liters of Hot Mixed Temp Cold divided by Hot Temp Cold Thermal Efficiency GPH X 8 25 X Temp Rise X 1 0 divided by BTU H Input BTU Output GPH X 8 25 X Temp Rise X 1 0 GPH BTU H Input X Eff divided by Temp Rise X 8 25 One cubic foot of Natural Gas contains about 1000 BTU of heat One therm is equal to 100 000 BTU One cubic foot of Propane Gas contains about 2500 BTU of heat One gallon of Propane gas contains about 91 250 BTU of heat One pound of Propane gas contains about 21 600 BTU of heat One pound of gas pressure is equal to 27 7 inches water column pressure Inches of Water Column X 036091 PSI Inches of Water Column X 073483 Inches of Mercury Hg Centimeters Inches X 2 54 mm millimeters Inches X 25 4 Meters Inches X 0254 Doubling the diameter of a pipe will increase its flow capacity approximately 5 3 times Construction Tank is constructed of steel The inside of the tank is constructed of a glass lining bonded to the steel This prevents water to metal contact and rusting of the tank An anode rod will be installed within the tank The hex head plug end of the anode is visible on the top of the water heater This metal rod offers secondary protection of the tank against corrosion where the application of glass is not possible thre
5. Installing Inner Door Manifold Burner Assembly 28 CLEANING THE BLOWER BLOWER In dusty and contaminated air conditions the interior of the blower and the blower wheel may require periodic cleaning This is often indicated by nuisance failures of the air pressure switch or the high limit temperature control A collection of dust or debris on the rear blower air intakes can also indicate reduced blower capacity To clean the inside of the blower assembly and the blower wheel requires the removal of the blower motor from the mounting plate located on the top of the heater Tools required include an 11 32 nut driver small 1 paintbrush toothbrush and vacuum cleaner 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Disconnectthe vent piping from the top of the blower Loosen the lower gear clamp that holds the rubber coupling to the blower 5 Remove and retain the 4 11 32 nuts located on the back of the blower with the nutdriver see Figure 32 6 Holding the blower motor and the blower housing pull the assembly forward to disengage it from the mounting plate The blower will still be connected to the junction box so exercise care not to stress the wi
6. L P Grasp the manifold tube and push down slightly to free the manifold tube from the gas control valve thermostat see Figure 15 7 Remove the insulation pad on the inner door by cutting it if necessary Keep the insulation in a safe place for reusing it later 8 Use a 1 4 nutdriver or 1 4 socket amp ratchet to loosen the 2 hex head screws on the inner door so the inner door manifold burner assembly can be removed see Figure 15 9 Remove inner door manifold burner assembly by grasping the manifold rotating it to the left to clear the igniter and flame sensor and pulling back Care should be taken when inner door and burner assembly passes through jacket opening that it does not damage any of the electrical wiring see Figure 17 Removing Burner 1 Burner may be hot Wait until burner has cooled off After noting the position of the condensation drain hole on the top of the burner turn the inner door manifold burner assembly upsidedown Using a Phillips head screwdriver remove and retain the 2 screws attaching the burner to the manifold pipe see Figure 18 amp 19 Installing Burner Care MUST be taken to ensure the burner is installed correctly on the inner door manifold assembly Position the new burner upside down with the orientation of the burner s condensation drain as shown in illustration see Figure 18 amp 19 1 Align the screw holes on the inner door manifold assembly Using the two screws remo
7. STEP 3 Open a nearby hot water faucet to relieve the vacuum STEP 4 Drain all the water from the tank a water hose may be needed STEP 5 Remove the anode rod s and close the drain valve STEP 6 Using a funnel in the anode opening add one gallon of household chlorine bleach for every 25 gallons of tank capacity STEP 7 Reinstall anode rod s after inspecting and replacing as needed Open cold water supply valve and refill the system Then draw the water to every hot water fixture until the smell of chlorine is detected Operate dish and clothes washers until a noticeable amount of the chlorine is detected as well All hot water lines must receive treatment STEP 9 Leave the chlorine solution undisturbed for one hour or more STEP 10 After the contact time has elapsed drain the tank according to steps 2 3 amp 4 STEP 11 Close the drain valve and refill the tank Allow the tank to sit for 15 minutes Repeat steps 2 3 and 4 Continue to flush the tank if the water is discolored or contains a chlorine odor STEP 12 Close the drain valve and refill the tank Flush all chlorine from the piping by opening every hot water outlet appliance STEP 13 Return hot water heating system to service by following the recommended start up procedure posted on the unit or in the manual NOT ENOUGH HOT WATER CAUSES The heating capacity of the water heater has been exceeded complaints regarding an insufficient supply of hot water are typically t
8. control thermostat Provide fresh air ventilation Purge the air from gas line Check the pressure switch make sure the pressure switch hose is not kinked Check vent pipe for blockage Check wire connections Replace the gas control thermostat Drain flush provide water treatment if needed See Strange sounds section in the Manual See Condensate section in the Manual See Temperature amp Pressure Relief Valve section in the Manual Check the Thermostat Back flush to clean out sediment replace if necessary See Leakage Checkpoints section Plug in power cord check fuses and or supply voltage Turn temperature knob to higher setting Replace air pressure switch Replace blower Repair and reconnect wires Reset determine cause of lockout Determine cause of insufficient draft Check draft with manometer at pressure switch Refer to Table 1 in the Manual for minimum acceptable draft setting a Remove blockage b Reduce vent length increase vent size c Clean blower wheel Reconnect or replace pressure switch hose Replace defective pressure switch Determine cause of overheating check for overfiring insufficient air supply high ambient air temperature once high limit switch activated must be replaced Replace igniter Replace gas control thermostat Refer to BLOWER WILL NOT START problem Proper air circulation must be provided for combustion and dilution of flue temp Room
9. replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 3 4 Open End Wrench Phillips Head Screwdriver Ratchet with 1 4 socket or 1 4 nutdriver Ratchet with 1 2 socket Removing Inner Door Manifold Burner Assembly 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the outer door from the unit 5 Unplug all the electrical connections from the bottom of the gas control valve thermostat see Figure 15 6 Using a 3 4 open end wrench remove the manifold tube from the gas control valve thermostat turning counter clockwise for natural gas clockwise for L P Grasp the manifold tube and push down slightly to free the manifold tube from the gas control valve thermostat see Figure 15 7 Removethe insulation pad on the inner door by cutting it if necessary Keep the insulation in a safe place for reusing it later 8 Usea 1 4 nutdriver or 1 4 socket amp ratchet to loosen the 2 hex head screws on the inner door so the inner door manifold burner assembly can be removed see Figure 15 9 Remove inner doo
10. the flame sensor igniter and valve 3 Removeandretainthescrew s securing the flame sensor and or hot surface igniter assembly see Figure 14 4 Remove and discard the old flame sensor and or hot surface igniter assembly Install the new Flame Sensor and or Hot Surface Igniter 6 Route the new flame sensor and or hot surface igniter connector wire through manifold burner door opening Secure the assembly to the bracket using screw s removed in step 3 above 7 Reconnect the wiring connection between the flame sensor igniter and the valve 8 Reposition the manifold component block in the manifold door opening and secure it with the retainer clip Caution Must Be Taken Prior to installing the new inner door manifold burner assembly look inside the burner chamber to fully understand the correct positioning of the burner assembly and burner manifold tab It may be necessary to use a flashlight to ensure correct placement Care must be taken so as to not damage any electrical wiring or components as you are installing the new inner door manifold burner assembly Extra caution should be taken to ensure that electrical wiring fiberglass insulation or any other object is not caught between door gasket and combustion chamber shield Note If the burner door gasket see Figure 9 is worn or damaged it needs to be replaced See section Door Gasket Replacement Re installing Inner Door Manifold Burner Assembly 1 Ins
11. the valve 7 Carefully pry against the casting until it barely slides past the locking tab edge 8 Repeaton the opposite side 9 Replace the valve Note When replacing the valve do not apply pressure with the hand on the valve pins 10 Re assemble in the reverse order Note During re assembly align the pins on the valve module to their proper location in the control module without causing damage SCREW AND GROUND TAB CASTING AND CASTING AND LOCKING TAB LOCKING TAB Figure 24 20 TEMPERATURE SENSOR AND CABLE REMOVAL REPLACEMENT TEMPERATURE SENSOR AND CABLE Important Do not remove the entire gas control assembly from the water heater Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required T15 Torx screwdriver Flat blade screwdriver Removing Temperature Sensor and Cable 1 Setthe gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 20 2 Turn gas control switch to the OFF position and turn off the gas supply to the unit see Figure 20 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the Electronic Control Module as outlined in Removing Electronic Control Module section above Note When removing the control mod
12. FF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the outer door from the unit 5 Unplug all the electrical connections from the bottom of the gas control valve thermostat see Figure 7 6 Using a 3 4 open end wrench remove the manifold tube from the gas control valve thermostat turning counter clockwise for natural gas clockwise for L P Grasp the manifold tube and push down slightly to free the manifold tube from the gas control valve thermostat see Figure 7 7 Remove the insulation pad on the inner door by cutting it if necessary Keep the insulation in a safe place for reusing it later 8 Use a 1 4 nutdriver or 1 4 socket amp ratchet to loosen the 2 hex head screws on the inner door so the inner door manifold burner assembly can be removed see Figure 7 9 Remove inner door manifold burner assembly by grasping the manifold and pull back slowly Rotating it to the left to clear the igniter and flame sensor Care should be taken when inner door and burner assembly passes through jacket opening that it does not damage any of the electrical wiring see Figure 9 Caution Must Be Taken Prior to installing the new inner door manifold burner look inside the burner chamber to fully understand the correct positioning of the burner assembly and burner manifold tab It is necessary to use a flashlight to ensure co
13. NIFOLD DOOR AND COMBUSTION CHAMBER Reconnect the manifold tube to the gas control valve thermostat Note Do Not apply any thread sealant at this connection To prevent any cross threading the manifold tube should be started by hand turn clockwise for natural gas counter clockwise for L P Upon tightening with the fingers and confirming it has not been cross threaded tighten nut with a 3 4 open end wrench see Figure 7 Reinstall the insulation pad which was removed in step 7 above Reconnect all the electrical connections to the bottom of the gas control valve thermostat gently pushing each connector up until it snaps into place see Figures 7 amp 10 Reconnect the electrical power to the water heater in the wall outlet and turn the main gas supply back ON to the gas control valve thermostat Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater Test gas connections by brushing on an approved non corrosive leak detection solution Note Do not splash the solution on control If a leak is detected shut the water heater down by following the directions on the Lighting and Operating Instructions Repair the leak s and repeat this step Upon verifying proper operation of the water heater replace the insulation and outer door 17 CONTROL MODULE REMOVAL REPLACEMENT ELECTRONIC CONTROL MODULE Important Do not
14. OR CURVED SLOT FOR 60 75K BURNERS WITH OFFSET MANIFOLD TUBES BRACKET LOCATED IN THE CENTRE OF THE CHAMBER 40 50K BURNERS WITH STRAIGHT MANIFOLD TUBES 0000000000 Figure 12 GASKET ON INSULATION REAR OF DOOR PAD OUTER DOOR COMBUSTION MOUNTING CLIP CHAMBER 1 EACH SIDE OPENING w RETAINER CLIP Q IGNITER SENSOR ASSEMBLY COMPONENT BLOCK Figure 14 BURNER AND ORIFICE REMOVAL REPLACEMENT BURNER Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 3 4 Open End Wrench Phillips Head Screwdriver Ratchet with 1 4 socket or 1 4 nutdriver Removing Inner Door Manifold Burner Assembly 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the outer door from the unit 5 Unplug all the electrical connections from the bottom of the gas control valve thermostat see Figure 15 6 Using a 3 4 open end wrench remove the manifold tube from the gas control valve thermostat turning counter clockwise for natural gas clockwise for
15. SLY HOT SURFACE IGNITER NOT GLOWING FOLLOWING WARM UP PERIOD VENT PIPE TOO HOT ABOVE 170 F Insufficient secondary air Low gas pressure Orifice too large Flue clogged Defective gas control thermostat Heater installed in a confined area Air in gas line Pressure switch Blocked exhaust Wire connection Defective gas control thermostat Scale and sediment Condensation dripping on burner Condensation Dripping Temperature amp 2 Pressure Relief Valve Thermostat does not shut off Drain valve dripping leaking Tank Leak No power to unit Thermostat set too low Defective air pressure switch Defective blower Disconnected or loose wire Control locked out Air pressure switch not closing due toinsufficient draft check for a Vent piping blocked b Piping length too long c Clogged dirty blower Disconnected torn or blocked pressure switch hose from air pressure switch to blower housing Defective pressure switch High limit switch open due to excessive vent temperature or defective switch Defective hot surface igniter Defective gas control thermostat Blower does not run when heater fired Not enough dilution air to mix with flue gases Air in room too hot for mixing with flue gases Wrong burner orifice Provide ventilation to water heater Check flue way flue baffle and burner Check with gas utility company Replace with correct orifice Clean locate source and correct Replace gas
16. Service Handbook RESIDENTIAL GAS WATER HEATERS POWER VENTED GAS MODELS WITH HOT SURFACE IGNITION NOT FOR USE IN MANUFACTURED MOBILE HOMES TABLE OF CONTENTS GENERAL INFORMATION 2 CHECKING THE GAS SUPPLY PRESSURE 3 LEAKAGE CHECKPOINTS 4 TEMPERATURE ADJUSTMENT 5 ANODE ROD REMOVAL REPLACEMENT 6 DIP TUBE REMOVAL REPLACEMENT 7 DOOR BURNER ASSEMBLY REMOVAL REPLACEMENT 8 FLAME SENSOR AND IGNITER REMOVAL REPLACEMENT 10 BURNER AND ORIFICE REMOVAL REPLACEMENT 12 DOOR GASKET REPLACEMENT 16 CONTROL MODULE REMOVAL REPLACEMENT 18 VALVE MODULE REMOVAL REPLACEMENT 20 TEMPERATURE SENSOR AND CABLE REMOVAL REPLACEMENT 21 GAS VALVE REMOVAL REPLACEMENT 22 BLOWER REMOVAL REPLACEMENT 24 ROTATING THE BLOWER 25 PRESSURE SWITCH REMOVAL REPLACEMENT 26 FV SENSOR 27 CLEANING THE COMBUSTION CHAMBER 28 CLEANING THE BLOWER 29 TECHNICAL BULLETINS 30 TROUBLESHOTING CHART 36 Note References to the Manual refer to the Installation and Operating Manual 1206 322153 000 Rev 00 GENERAL INFORMATION Draw efficiency is the quantity of hot water available to the consumer before the outlet water temperature decreases by 25F 14C A 40 gallon water heater will typically provide 70 28 gallons of this usable hot water 60 is the minimum The burner or elements are allowed to operate during this test Incoming cold water mixes the remaining stored water below this 25F 14C limitation Energy Factor is an indicator of the com
17. THE MODULE ELECTRONIC CONTROL STRAIGHT UP THREADED CONTROL FITTING DO NOT REMOVE FROM WATER HEATER VALVE MODULE Figure 22 ELECTRONIC CONTROL MODULE DISCONNECT TEMPERATURE SENSOR CABLE HERE THREADED P N FITTING DO NOT REMOVE FROM WATER HEATER Figure 23 19 VALVE MODULE REMOVAL REPLACEMENT VALVE MODULE Important Do not remove the entire gas control assembly from the water heater Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required T15 Torx screwdriver Flat blade screwdriver Removing Valve Module 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 20 2 Turn gas control switch to the OFF position and turn off the gas supply to the unit see Figure 20 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the Electronic Control Module as outlined in Removing Electronic Control Module above Note When removing the control module from the gas control assembly disengage the pins on the valve module without causing damage 5 Remove the screw and the ground tab with a Torx screwdriver see Figure 24 6 Insert a flat blade screwdriver between the casting and the locking tabs at the bottom of
18. Unplug all the electrical connections from the bottom of the gas control valve thermostat see Figure 7 6 Using a 3 4 open end wrench remove the manifold tube from the gas control valve thermostat turning counter clockwise for natural gas clockwise for L P Grasp the manifold tube and push down slightly to free the manifold tube from the gas control valve thermostat see Figure 7 7 Remove the insulation pad on the inner door by cutting it if necessary Keep the insulation in a safe place for reusing it later 8 Use a 1 4 nutdriver or 1 4 socket amp ratchet to loosen the 2 hex head screws on the inner door so the inner door manifold burner assembly can be removed see Figure 7 9 Remove inner door manifold burner assembly by grasping the manifold and pull back slowly Rotating it to the left to clear the igniter and flame sensor Care should be taken when inner door and burner assembly passes through jacket opening that it does not damage any of the electrical wiring see Figure 9 Removing The Door Gasket 1 Locate the gasket that is on the rear of the burner door assembly see figure 17 19 2 Pull off this gasket and using the 3 4 scraper scrape away and gasket stuck to the door 3 Using the 3 4 scraper clean around the combustion chamber opening to ensure no old gasket material is stuck on the combustion chamber Figure 17 Use the flashlight to clearly illuminate this area Take care not to damage
19. aded tank openings These areas will have small areas of water to metal contact All water heaters will contain at least one thermostat to operate the heater and one high limit to prevent water from overheating CHECKING THE GAS SUPPLY PRESSURE Gas pressure checks are done with flowing gas using a gas pressure manometer capable of reading pressure in inches of water column Supply gas pressure checks are measured before the gas control valve and as close to the water heater as possible Manifold main burner gas pressure is measured at the pressure tap on the bottom of the gas control valve see Figure 1 Use an allen wrench to remove the plug then attach the gas gauge Note Desired gas pressures will be noted on the gas valve label located on the gas control valve and rating plate Supply gas pressure Increase supply gas is under desired pressure regulator setting pressure requirement Call the gas utility company to readjust gas pressure on main supply Technicians can not adjust main gas supply pressure MANIFOLD MAIN BURNER GAS PRESSURE PRESSURE TAP RE INSTALL PLUG AFTER USE MANOMETER Figure 1 Supply gas pressure Add gas pressure is over desired regulator pressure Call the gas utility company to readjust gas pressure on main supply Technicians can not adjust main gas supply pressure Manifold gas pressure Ensure there is adequate is more than 4 supply gas pressure inch W C from values E
20. air to be used for dilution with combustion products in flue should be less than 90 F Install correct orifice 37 GAS CONTROL LED STATUS CODES IGNITION STATE AND TIMING LED Flash Sequence Control Status IGNITION STATE TIMING xd id T IDLE no call for heat Pisspuie 5 seconds NG models seon HSI Warmup Heartbeat Call For Heat lanition Activati alternates bright dim no fault conditions Period IAP on One Flash Low Flame Signal three second pause control continues to operate Flame Pecognitign 0 5 second Two Flash P Switch Failed a wo Flash ressure Switch Faile three second pause Trial For Ignition IAP FRP Three Flash Not Applicable three second pause Pressure Switch Failed Open Period inter purge Four Flash m three second pause VAS TIME ence Flame Failure 2 seconds max Five Flash NER eae Response Time 1uA flame current three second pause a Post purge PS Prove Period Six One Flash FOIE EOCKOHE Retry Limit PS Fault Delay ree Sepon pause UE leg Tri failed open closed 2 minutes Six Two Flash So Loco Soft Lockout Recycle Limit PS Limit opened TCO Limit Lockout Soft Lockout Recycle Limit Flame Lost Soft Lockout Flame out of Sequence Sensed Seven Flash Flammable Vapor Sensor three second pause Lockout EloRt ne Flash FVS Fault Detected three second pause Eight Two Flash Temperature Sensor Fault three second pause Detected Piane Three Flash Electronics Faul
21. all possible water sources is made and necessary corrective steps taken J Leakage from other appliances water lines or ground seepage should also be checked To check where threaded portion enters tank insert cotton swab between jacket opening and fitting If cotton is wet follow draining instructions in the Draining and Flushing section in the Manual and then remove fitting Put pipe dope or Teflon tape on the threads and replace When you are finished follow the steps in Filling the Water Heater section in the Manual Figure 2 TEMPERATURE ADJUSTMENT Safety Due to the nature of the typical gas water heater the water temperature in certain situations may vary up to 30F 16C higher or lower at the point of use such as bathtubs showers sink etc HOT WATER CAN SCALD Water heaters are intended to produce hot water Water heated to a temperature which will satisfy space heating clothes washing dish washing and other sanitizing needs can scald and permanently injure you upon contact Some people are more likely to be permanently injured by hot water than others These include the elderly children the infirm or physically mentally handicapped If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring certain temperature water at the hot water tap then you must take special precautions In addition of using the lowest possible temperature
22. allon of water vapor during every hour of operation Condensate is often mistaken for leaking Newer heaters will condensate more than older heaters because modern water heaters are much more efficient than their predecessors The newer heaters utilize as much of the energy out of the main burner flame as possible This lowers the flue gas and tank storage temperature and closer to the dew point temperature To distinguish between a condensating water heater and a leaking water heater 1 Wipe up any water under the heater 2 Turn gas control switch to the OFF position 3 Wait 8 hours check for water accumulation under the heater 4 Condensation should stop when the entire tank water is heated above approximately 115 F a If no water is under the heater the water heater was condensating b If water is under the heater check further for a loose fitting If all fittings are tight and the tank is leaking replace the water heater Leaking heaters cannot be repaired DISCOLORED WATER SYMPTOMS Rusty brown black or yellow water appearing in the hot water CAUSES TREATMENT Complaints of discolored water are commonly blamed on water heaters and storage tanks but in fact it is a rare occurrence for today s high quality glass lined tanks to have a lining failure significant enough to allow water to contact enough bare metal to discolor the contents of even a small tank The most common cause of rusty water is a non toxic iro
23. arged from the relief valve The temperature and pressure relief valve T amp P is a safety device limiting temperature and pressure levels in a water heater Each T amp P has both a temperature and pressure rating Normally the temperature and pressure relief valve will have a temperature rating of 210 F A probe part of the relief valve extends into the tank measuring the stored water temperature This probe must be within the top six inches of the water heater If the water heater s thermostat malfunctions higher than normal water temperatures could be produced Once the probe senses a temperature approaching its temperature rating the relief valve will open to full capacity releasing very hot water until the temperature is below its reset temperature The pressure rating on the relief valve should be the same or less than the certified working pressure of the tank generally 150 psi and be below the lowest maximum working pressure rating of any system components Once the pressure in the tank reaches the valve s pressure rating it will slightly open relieving the pressure Relieving of pressure can be noted as dribbling or weeping water from the relief valve If an incorrectly sized temperature and pressure relief valve is installed the warranty will be void Follow these easy steps to diagnose thermal expansion Intermittent weeping and or dribbling at the relief valve The relief valve relieves water slowly when actuating on
24. ations along the shell Pressures in excess of the maximum design working pressure can cause permanent deformation of the shell Note The continuous expansion of the tank shell may cause the tank to rupture at a welded seam Collapsed Flue Tube This will choke off the ability to vent the products of combustion causing the flame and or combustion to spill out from the combustion chamber Often this will occur where thinning of the flue tube walls has occurred due to contamination of the combustion air or because of excessive condensation Inverted or Deformed Tank Heads Often this accompanies collapsed flues but one or both heads can be deformed The only effective means of control is to install water hammer arrestors These devices have diaphragms which separate an air chamber from the water in the piping system As the shock wave reaches this device the air chamber absorbs the shock Arrestors should be located as close as possible to the source of the shock wave Since water hammer exposes the equipment to pressures in excess of its design limits failures caused by water hammer are not eligible for warranty consideration MINERAL BUILD UP Rumbling Crackling Popping With the increase in fuel costs and hot water consumption deliming has become a necessity of modern maintenance Lime CaCO is the most notable factor when discussing water hardness Lime is present in every water system to some degree Since lime is inversely sol
25. bined thermal efficiency and standby efficiency of a water heater The higher the energy factor the more efficient the water heater will be Minerals and gases will separate from water as temperature increases R Value is a measure of the resistance of a substance to heat flow Recovery rate is the amount of water that is heated to a set temperature per hour Standby efficiency is the water heater s ability to contain heat in the tank A minimum of tank water heat loss per hour is desired e g temperature change R value Btu h loss square foot of tank surface Temperature rise is the increase in the temperature from its coldest inlet water temperature to the desired hot outlet setting Typically it is assumed that the entering water be 40 F 5 C stored water desired to be 120 F 49 C resulting in a temperature rise of 80F 44C Thermal efficiency is approximately the amount of generated BTU British Thermal Units which enters the water A percentage of the total BTU passes out through the vent piping Water cannot for all practical purposes be compressed Water expands when it is heated Formulas and Conversions BTU British Thermal Unit is the heat required to raise 1 pound of water 1F 1 BTU 252 cal 0 252 kcal 1 cal 4 187 Joules BTU X 1 055 Kilo Joules BTU divided by 3 413 Kilowatts To convert from Fahrenheit to Centigrade F 32 times 5 9 or 556 equals degrees
26. connect the electrical power to the water heater from the wall outlet 4 Release water pressure by opening a nearby hot water faucet let run until water is cool to touch Turn off water supply to the water heater 5 Remove the outer door from the unit 6 Connect a drain hose to the drain valve and run it to an adequate drain or to the exterior of the building Open the water heater drain valve and allow the water to drain from the tank 7 Unplug all the electrical connections from the bottom of the gas control valve thermostat see Figure 26 8 Using a 3 4 open end wrench remove the manifold tube from the gas control valve thermostat turning counter clockwise for natural gas clockwise for L P Grasp the manifold tube and push down slightly to free the manifold tube from the gas control valve thermostat see Figure 26 9 Ensuring that the gas supply line is turned off disconnect the gas piping at the ground joint union then remove the gas piping from the gas control valve thermostat 10 Remove any other fittings that may be installed on the threaded pipe to the gas control valve thermostat 11 After ensuring the water heater is completely drained thread a short length of 1 2 threaded pipe into the inlet connection of the gas control valve thermostat and use it to turn the gas control valve thermostat counter clockwise to remove see Figure 27 Do not use any type of wrench on the valve body as it may cause damage to t
27. d in step 8 above Care should be taken to ensure the proper orientation of the bracket and pressure switch see Figure 30 Using a hex head hex screwdriver secure the bracket to the junction box with the screws removed in step 7 above see Figure 30 Reattach the two 2 electrical flag terminals by pushing the flag terminals onto the switch Care MUST be taken to ensure that each of the electrical flag terminals is in its original position Reattach the air pressure tubing to the air pressure switch by pushing the tubing onto the connector until the end of the tubing reaches the shoulder of the connector Replace the blower s junction box door by reusing the screw removed in step 4 above Reconnect the electrical power to the water heater in the wall outlet and turn the gas supply back ON to the gas control valve thermostat Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater AIR PRESSURE TUBING JUNCTION BOX JUNCTION PRESSURE SWITCH BRACKET Figure 30 FV SENSOR FLAMMABLE VAPOR SENSOR When using a gas fired water heater there is a risk of flammable vapors entering the combustion chamber being ignited by the burner flame and causing a flashback In order to detect such flammable vapors before they enter the combustion chamber this water heater is equipped with a flammable vapor sensor FVS It is a chemical
28. e of 40 000 to 50 000 Btu hr to obtain proper installation The tip end of the burner manifold MUST be placed in the lower slotted portion for models with input rate of 60 000 to 75 000 Btu hr to obtain proper installation 2 After confirming no materials of any type are between door gasket and combustion chamber shield align the screws on the inner door with the screw holes on the combustion chamber and tighten with 1 4 nutdriver or 1 4 socket amp ratchet see Figure 15 After tightening the inner door screws visually inspect area around door gasket and skirt for spaces or gaps The door gasket MUST be sealed completely in order for the water heater to perform properly DO NOT OPERATE THE WATER HEATER IF THE DOOR GASKET DOES NOT CREATE A SEAL BETWEEN MANIFOLD DOOR AND COMBUSTION CHAMBER 3 Reconnect the manifold tube to the gas control valve thermostat Note Do Not apply any thread sealant at this connection To prevent any cross threading the manifold tube should be started by hand turn clockwise for natural gas counter clockwise for L P Upon tightening with the fingers and confirming it has not been cross threaded tighten nut with a 3 4 open end wrench see Figure 15 4 Reconnect all the electrical connections to the bottom of the gas control valve thermostat gently pushing each connector up until it snaps into place see Figures 10 amp 15 GASKET ON INSULATION REAR OF DOOR 5 Reconnect the electrica
29. e blower assembly may be rotated 90 degrees clockwise or counter clockwise to allow horizontal venting in areas having restricted space above the water heater see Rotating the Blower section VENTING PR JUNCTION BOX COVER JUNCTION Figure 28 ROTATING THE BLOWER BLOWER EXHAUST DIRECTION Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required Ratchet with 11 32 socket or 11 32 nutdriver The blower assembly may be rotated 90 degree clockwise or counterclockwise to allow horizontal venting in areas having restricted space above the water heater To rotate the blower outlet remove the four nuts with 11 32 nut driver see Figure 29 securing the flue collector to the blower housing Pull the blower assembly forward to free it from the mounting studs Rotate the blower housing clockwise or counter clockwise and align the four holes and screws together Reattach the blower housing to the flue collector Figure 29 This power vent heater can accept 2 or 3 rubber outlet coupling depending on the capacity of the water heater This coupling mounted in the vertical position accepts the vent piping and is attached as shown in Figure 28 25 PRESSURE SWITCH REMOVAL REPLACEMENT Installing Pressure Switch PRESSURE SWITCH Important Us
30. e inlet water piping connected to the cold inlet of the water heater see Figures 5 amp 6 Some installations will have a union connection others will have the supply piping soldered to an adapter that connects to the nipple on the water heater Using the pipe wrench remove the piping from the top of the tank 7 With the piping removed use the pipe wrench on the exposed nipple directly to remove it from the heater Note Sometimes the dip tube will come out with the piping in one piece Separate accordingly Installing Dip Tube 1 Use Teflon tape or an approved pipe sealant on threads of the new dip tube 2 Place the dip tube into the spud on top of the tank and turn clockwise until tight Using the pipe wrench continue to tighten until the joint is water tight Note Do not clamp the pipe wrench jaws on the threaded portion of the nipple and do not over tighten This can cause the threads to distort and can result in a leak 3 Apply Teflon tape or pipe sealant on the top threads and reconnect the water piping see Figure 6 4 Turn the main water supply back on 5 Open a nearby hot water faucet to purge air from the water line Fill water heater tank completely Note To assure the water heater tank is full keep the hot water faucet open for 3 minutes after a constant flow of water is obtained 6 After turning off the hot water faucet check for water leaks around dip tube and immediately correct any if found R
31. e is relieved and the stretched tank returns to a natural shape Faucet drips during any recovery cycle when no hot or cold water is used Water surges when a faucet is first opened and then pressure drops The water in a water heating system expands when it is heated and increases in volume Since water will not compress like air system designers must include provisions for thermal expansion Water in a closed tank at 50 psi when heated just 10 degrees will reach a pressure of 250 psi Many water supply systems have check valves or back flow preventers at the water meter to prevent any possible contamination of the public water supply by the accidental back flow of contaminated water into the supply mains These check valves are often required by code and some cities are even installing the check valves They serve a useful purpose Do not remove them The use of pressure reducing valves PRV is another cause PRVs are designed to conserve water and prolong fixture life Many PRVs also act as very effective check valves Again do not remove them Water softeners in the system may also act as back flow preventers Follow these easy steps to diagnose thermal expansion Turn gas control switch to the OFF position and install a water pressure gauge with dead hand on the drain valve Open the drain valve so the gauge reads system pressure Open a hot water tap and allow 15 to 20 of the tanks volume to run out Shut off the drain valve a
32. e new burner upside down with the orientation of the burner s condensation drain as noted in Removing Burner Orifice step 1 3 Align the screw holes on the inner door manifold assembly Using the two screws removed in step 1 above installed the new burner to the inner door manifold assembly rotate the assembly to visually check the top portion of the burner assembly and confirm the orientation of the condensation drain hole as shown in the illustration see Figure 18 amp 19 Caution Must Be Taken Prior to installing the new inner door manifold burner assembly look inside the burner chamber to fully understand the correct positioning of the burner assembly and burner manifold tab It may be necessary to use a flashlight to ensure correct placement Care must be taken So as to not damage any electrical wiring or components as you are installing the new inner door manifold burner assembly Extra caution should be taken to ensure that electrical wiring fiberglass insulation or any other object is not between door gasket and combustion chamber shield Note If the burner door gasket see Figure 9 is worn or damaged it needs to be replaced See section Door Gasket Replacement Reinstalling Inner Door Manifold Burner Assembly 1 Insert the manifold burner assembly in the burner chamber compartment making sure that the tip of burner manifold tab engages in the proper slot of the bracket see Figure 16 Important
33. e only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required Phillips Head Screwdriver Ratchet with 1 4 socket or 1 4 nutdriver Removing Pressure Switch 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Usea 1 4 nutdriver or 1 4 socket amp ratchet to loosen the screw on the junction box Remove and retain the screw and junction box cover see Figure 30 5 Remove the air pressure tubing from the air pressure switch by pulling upward on the tubing at the connection to the air pressure switch 6 Afternoting the position of each electrical flag terminals remove the two 2 electrical flag terminals from the switch by pulling outward and off the switch 7 Using a hex head screwdriver remove and retain the 2 screws securing the bracket to the junction box see Figure 30 8 Using a hex head screwdriver remove and retain the 2 screws securing the pressure switch to the bracket see Figure 30 26 1 Using a hex head screwdriver secure the new pressure switch to the bracket with the screws remove
34. einstall the pipe insulation removed in step 4 removal process Reconnect the electrical power to the water heater in the wall outlet and turn the gas supply back ON to the gas control valve thermostat Turn the gas control switch to the ON position see Figure 3 To restart the water heater follow the directions on the Lighting and Operating Instructions label located on the front of the water heater near the gas control valve thermostat NIPPLE DIP TUBE Figure 5 SHUT OFF VALVE HOT WATER OUTLET Iy gu L3 COLD B WATER UNION amp amp 4 UNION MESE B B 3 4 SWEAT gt E4 34 sweat FITTING anc NIPPLE DIP TUBE TEMPERATURE PRESSURE RELIEF VALVE BLOWER ASSEMBLY COMPONENTS NOT SHOWN FOR CLARITY Figure 6 DOOR BURNER ASSEMBLY REMOVAL REPLACEMENT INNER DOOR MANIFOLD BURNER ASSEMBLY Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 3 4 Open End Wrench Phillips Head Screwdriver Ratchet with 1 4 socket or 1 4 nutdriver Flashlight Removing Inner Door Manifold Burner Assembly 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the O
35. er CAUSES The most common cause of smelly water is a non toxic sulfate reducing bacteria scientifically termed Divibrio Sulfurcans This bacteria often enters the water system through construction or a break in ground piping The bacteria create the energy it needs to survive by converting sulfate SO to hydrogen sulfide H S gas you smell in the water Hydrogen sulfide gas is distinctive because of its rotten egg like stench Its presence can severely affect the taste as well as the odor of the water Occasionally this bacteria can be accompanied by black deposits the result of pipe and fitting corrosion In extremely high concentrations hydrogen sulfide gas can be toxic though the gas is detectable long before harmful levels are reached The requirements for the bacteria to thrive are Elevated levels of iron and manganese in the water Water with little or no dissolved oxygen Temperatures below 138 F Items that can increase the potential for this bacteria are Water softeners Well water Long periods of no water movement Other factors that may contribute to smelly water Chlorides of Magnesium and Calcium leave a bitter taste Chloride of Sodium produces a salty taste Sulfates 50 ppm gives a medicinal taste Carbon Dioxide in low pH water gives fizzy water Iron and tannic waters also give a bad taste and odor TREATMENT The simplest treatment available is the shock chlorination of the system
36. er in the heater is hot the unit will wait to operate until there is a need for more hot water COUPLING REAR BLOWER AIR INTAKES MOUNTING BLOWER PLATE Figure 32 29 TECHNICAL BULLETINS GENERAL EFFECTS THE FIX NOTES SYMPTOMS CAUSE THE FIX 30 WATER HAMMER Water hammer is the destructive force pounding noise and vibration in a piping system when water flowing through a pipeline is stopped abruptly When water hammer occurs a high intensity pressure wave travels back through the piping system until it reaches a point of some relief The shock wave will then surge back and forth between the point of relief and the point of stoppage until the destructive energy is dissipated in the piping system The violent action accounts for banging thumping and or intense vibration in the pipe line Although noise is generally associated with the occurrence of water hammer it can occur without audible sound or noise Quick closure of valves always causes some degree of shock with or without noise The common cause of water hammer is single lever faucets sinks lavatories or automatic solenoid valves dishwashers washing machines etc The speed of the valve closure time is directly related to the intensity of the surge pressure The damage from water hammer can manifest itself in a number of ways The most common are Expanded Tank Shell This can be demonstrated by measuring the circumference at various loc
37. ert the manifold burner assembly in the burner chamber compartment making sure that the tip of burner manifold tab engages in the proper slot of the bracket see Figure 12 The tip end of the burner manifold MUST be placed in the slotted portion under the condensation pan to obtain proper installation see Figure 12 Important The tip end of the burner manifold MUST be placed in the upper slotted portion for models with input rate of 40 000 to 50 000 Btu hr to obtain proper installation The tip end of the burner manifold MUST be placed in the lower slotted portion for models with input rate of 60 000 to 75 000 Btu hr to obtain proper installation 2 After confirming no materials of any type are between door gasket and combustion chamber shield align the screws on the inner door with the screw holes on the combustion chamber and tighten with 1 4 nutdriver or 1 4 socket amp ratchet see Figure 11 After tightening the inner door screws visually inspect area around door gasket and skirt for spaces or gaps The door gasket MUST be sealed completely in order for the water heater to perform properly DO NOT OPERATE THEWATERHEATERIFTHE DOOR GASKET DOES NOT CREATE A SEAL BETWEEN MANIFOLD DOORAND COMBUSTION CHAMBER Reconnect the manifold tube to the gas control valve thermostat Note Do Not apply any thread sealant at this connection To prevent any cross threading the manifold tube should be started by hand turn clockwi
38. he gas control valve thermostat assembly 22 Installing Gas Control Valve 1 11 12 Do not apply any sealant tape to the gas control thermostat threads that screw into the tank The threads have a pre applied white sealing material Thread a short length of 1 2 threaded pipe into the inlet connection of the new gas control valve thermostat and use it to turn the gas control valve thermostat clockwise to tighten into place Note Do Not over tighten or damage may result but it needs to be water tight see Figure 27 Remove the 1 2 threaded pipe from the gas control valve thermostat Reconnect the gas piping to the gas control valve thermostat use Teflon amp tape or an approved pipe sealant on threads of the piping Close the drain valve and turn on the cold water supply line filling the tank completely with water Purge the water lines of any excess air by opening a hot water faucet allowing the water to flow for a minimum of 3 minutes allowing the tank to fill completely Reconnect the manifold tube to the gas control valve thermostat Note Do Not apply any thread sealant at this connection To prevent any cross threading the manifold tube should be started by hand turn clockwise for natural gas counter clockwise for L P Upon tightening with the fingers and confirming it has not been cross threaded tighten nut with an 3 4 open end wrench see Figure 26 Reconnect all the electrical connections to the bot
39. he result of a water heater that cannot meet the demands of the residence both people and appliances The demand for sufficient hot water may also be exceeded if additional people and or appliances are added to the residence Operating Set Point is too low Mineral build up Hot water supply valve s to fixtures not fully open Inlet outlet water piping connections to water heater reversed Dip tube inside water inlet connection missing THE FIX Compare hot water requirements with the capacity of the water heater If necessary install a water heater with greater capacity Turn temperature knob to desired temperature as described in the Manual Drain the tank see Draining and Flushing section in the Manual Determine if water treatment is needed Check to see if hot water supply valve is fully open check inlet outlet piping connections to water heater are not reversed check to see if the dip tube inside water inlet connection is not missing 33 SYMPTOMS CAUSE TEST THE FIX WARNING 34 THERMAL EXPANSION Effects are only noticeable after hot water use followed by periods of no water use Relief valve drips during any recovery cycle when no hot or cold water is used Hot water pipes creak while water heater is recovering and all valves are closed Tanks or other components of the water supply system fail prematurely A metallic creaking noise might actually be heard in the location of the heater as the pressur
40. into place see Figures 10 amp 15 Reconnect the electrical power to the water heater in the wall outlet and turn the gas supply back ON to the gas control valve thermostat Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater As the burner is heating view flames through viewport test the manifold tube connection at the gas control valve thermostat by brushing on an approved noncorrosive leak detection solution Important Do Not splash any solution onto any electrical connections Upon verifying proper operation of the water heater replace the outer door 15 DOOR GASKET REPLACEMENT DOOR GASKET Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 3 4 Open End Wrench 3 4 Scraper Ratchet with 1 4 socket or 1 4 nutdriver Flashlight Removing Inner Door Manifold Burner Assembly 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the outer door from the unit 5
41. l power to the water heater in the wall outlet and turn the gas supply back ON to OUTER DOOR the gas control valve thermostat 6 Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater 7 As the burner is heating view flames through viewport test the manifold tube connection at the gas control valve thermostat by brushing on an approved noncorrosive leak detection solution Important Do Not splash any solution onto any SUN eit COMBUSTION i i CHAMBER electrical connections f 1 EACH SIDE OPENING 8 Upon verifying proper operation of the water heater replace the outer door Figure 17 BURNER ORIFICE IGNITER A AND FLAME DRAIN HOLE AT 2 O CLOCK POSITION SCREWS gt CONNECTIONS Bi MANIFOLD TUBE NUT MANIFOLD For 40 000 to 50 000 Btu hr DRAIN HOLE AT 2 O CLOCK POSITION BURNER IGNITER AND FLAME sm NOTE OUTER DOOR AND INSULATION NOT SHOWN FOR CLARITY Figure 15 BURNER SUPPORT STRIGHTSLOT FOR CURVED SLOT FOR BRACKET 40 50K BURNERS 60 75K BURNERS LOCATED IN THE WITH STRAIGHT WITH OFFSET CENTRE OF THE MANIFOLD TUBES MANIFOLD TUBES CHAMBER MANIFOLD lI Figure 16 Figure 19 Note The drain hole must be at the 2 o clock position directly opposite the igniter and flame rod For 60 000 to 75 000 Btu hr models 13 BURNER ORIFICE Important Use only factory authorized
42. n reducing bacteria scientifically termed Crenothrix Leptothrix and Gallionella Iron bacteria is commonly found in soil water wells water treatment plants and water distribution piping systems where soluble iron exceeds 0 2 ppm higher levels make conditions even more favorable Soluble iron in the water provides food for the bacteria Rusty discolored water is the end result of the bacteria feeding process Water heaters and storage tanks usually require new anode rods as presence of iron bacteria contributes to premature anode failure The requirements for the bacteria to thrive are Elevated levels of iron and manganese in the water Water with little or no dissolved oxygen Temperatures below 138 F Items that can increase the potential for this bacteria are Water softeners Well water Long periods of no water movement The simplest treatment available is shock chlorination of the system This is a surface treatment and often requires repeated trials in heavily infected systems The chlorination of a system requires that you follow each step explicitly to avoid an untreated portion of the piping system from re infecting another part See the Chlorination Procedure section NOTES Since rusty water is caused by a bacteria presence and is not caused by the water heater any treatment would not be considered warranty related 31 SMELLY WATER SYMPTOMS Rusty brown black or yellow water appearing in the hot wat
43. nd make sure that no other fixture in the system hot or cold is open Make sure that outside fixtures if they are on the same system are turned off too Any water leaks or use will make the test meaningless Check the water pressure gauge and turn the pointer so it lines up with the pressure indicating needle Turn the gas control switch ON so the heater cycles on Watch the pressure gauge If the system is closed the pressure will start to climb steadily and rapidly A small amount of thermal expansion control may be built into the system because of trapped air pockets or a water hammer arrestor In that case the pressure will increase slightly hold steady for a short time and then rapidly increase The temperature and pressure relief valve T amp P or PRV should open and release water once the pressure reaches the maximum setting on the valve The valve will close once the pressure falls below the pressure setting of the valve The ideal fix involves the use of a pressure reducing valve if supply pressures are above 60 to 70 psi and a properly sized expansion tank The PRV reduces supply pressures to 40 to 60 psi allowing an economically priced and sized expansion tank to be used The PRV also offers the benefit of saving water and prolonging the life of water flow valves The PRV is not required if the system already has one or if high supply pressures are desired A supply water pressure of 80 PSI is a maximum set by many codes The PRV i
44. nsure the main burner indicated on gas valve orifice is the correct size or rating plate for the water heater model being tested Ifthe above tests have been performed and the results were correct replace the gas control valve Important After checking the manifold gas pressure detach the gas gauge reinstall the plug using insulation tape and tighten with allen wrench Check for leaks and repair as required LEAKAGE CHECKPOINTS A Water at the blower assembly is water vapor which has condensed out of the combustion products This is caused by a problem in the vent or blockage in the drain coupling B Condensation may be seen on pipes in humid weather or pipe connections may be leaking C The anode rod fitting may be leaking D Small amounts of water from temperature pressure relief valve may be due to thermal expansion or high water pressure in your area E The temperature pressure relief valve may be leaking at the tank fitting F Water from a drain valve may be due to the valve being slightly opened G The drain valve may be leaking at the tank fitting H Combustion products contain water vapor which can condense on the cooler surfaces of the tank Droplets form and drip onto the burner This is common at the time of start up after installation and when incoming water is cold Water in the water heater bottom or on the floor may be from condensation DO NOT replace the water heater until a full inspection of
45. nt for a lower setting Should overheating occur or the gas supply fails to shut off turn OFF the manual gas control valve to the water heater The following table lists the approximate water temperatures produced by various dial settings Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat setting by up to 30F 16C If you experience this type of use you should consider using lower temperature settings to reduce scald hazards Listed below is time to burn relationship for normal adult skin E w Temperature Setting ANODE ROD REMOVAL REPLACEMENT Installing Anode Rod ANODE ROD Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required Ratchet with 1 1 16 Socket Pliers Teflon Tape or an approved pipe sealant Removing Anode Rod 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Shutoffthe incoming water supply to the water heater and open a nearby hot water faucet to depres
46. ontrol 2 Replace gas control thermostat ORIFICE thermostat 1 Low gas pressure 1 Check with gas utility company 2 Orifice too small 2 Replace with correct orifice 3 Thermostat set too low 3 Turn temperature knob to higher setting 4 Gas control error codes 4 Referto gas control error code in the Installation 5 Sediment or lime in tank and Operating Manual INSUFFICIENT HOT 6 Water heater too small 5 Drain flush provide water treatment if needed WATER 7 Wrong piping connections 6 Install adequate heater 8 Leaking faucets 7 Correct piping dip tube must be in cold inlet 9 Wasted hot water 8 Repair faucets 10 Long runs of exposed piping 9 Advise customer 11 Hot water piping in outside 10 Insulate piping wall 11 Insulate piping 1 Thermostat is too high 1 Turn temperature knob to lower setting WATER IS TOO HOT 2 Defective gas control 2 Replace the gas control thermostat thermostat 1 Insufficient secondary air 1 Provide ventilation to water heater Check flue 2 Low gas pressure way flue baffle and burner 3 Orifice too small 2 Check with gas utility company 4 Thermostat set too low 3 Replace with correct orifice SLOW HO LN TEB 5 Heater too small 4 Turn temperature knob to higher setting RECOVERY 6 Wrong piping connection 5 Install adequate heater 7 Wasted hot water 6 Correct piping dip tube must be in cold inlet 8 Flue clogged 7 Advise customer 8 Clean flue locate source and correct 1 P
47. or screws visually inspect area around door gasket and skirt for spaces or gaps The door gasket MUST be sealed completely in order for the water heater to perform properly DO NOT OPERATE THE WATER HEATER IF THE DOOR GASKET DOES NOT CREATE A SEAL BETWEEN MANIFOLD DOOR AND COMBUSTION CHAMBER Reconnect the manifold tube to the gas control valve thermostat Note Do Not apply any thread sealant at this connection To prevent any cross threading the manifold tube should be started by hand turn clockwise for natural gas counter clockwise for L P Upon tightening with the fingers and confirming it has not been cross threaded tighten nut with a 3 4 open end wrench see Figure 7 Reinstall the insulation pad which was removed in step 7 above Reconnect all the electrical connections to the bottom of the gas control valve thermostat gently pushing each connector up until it snaps into place see Figures 7 amp 10 Reconnect the electrical power to the water heater in the wall outlet and turn the main gas supply back ON to the gas control valve thermostat Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater Test gas connections by brushing on an approved non corrosive leak detection solution Note Do not splash the solution on control If a leak is detected shut the water heater down by following the directions on the Lighting and Ope
48. position see Figure 3 To restart the water heater follow the directions on the Lighting and Operating Instructions label located on the front of the water heater near the gas control valve thermostat THE ANODE ROD IS COVERED BY URETHANE FOAM LOCATED UNDER THE CAP CHIP AWAY THE FOAM TO EXPOSE THE TOP OF THE ANODE ROD Figure 4 DIP TUBE REMOVAL REPLACEMENT DIP TUBE Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 18 Pipe wrench Piping and soldering equipment Teflon Tape or an approved pipe sealant Removing Dip Tube 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Shutoffthe incoming water supply to the water heater and open a nearby hot water faucet to depressurize the water tank Remove pipe insulation from cold inlet piping 5 Connect a hose to the drain valve and terminate it to adequate drain or to the exterior of the building Open the drain valve and allow at least 5 gallons of water to drain from the tank Close drain and remove hose 6 Remove th
49. pressure A closed system can cause pressure to increase in the system This condition is called thermal expansion For additional information regarding thermal expansion please see thermal expansion section on of the Installation and Operating Manual Leaking at the spud of the water heater Spuds are welded to the tank and are not repairable The heater should be replaced Leakage at the threaded relief valve connection Remove relief valve and reseal connection Large volume of hot water sporadically discharged from the relief valve The relief valve relieves water quickly when actuating on temperature The only cause of this problem is a malfunctioning thermostat INSULATION BLANKETS The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters Most modern water heaters have adequate factory installed insulation the use of an after market insulation blanket is no longer recommended by most experts While the use of an external insulation blanket will not void the warranty the water heater manufacturer explicitly disclaims any liability for problems associated with the use of insulation blankets Note A few local energy codes may still require the use of insulation blankets on waters heaters Be sure to follow all installation instructions cautions and warnings for the insulation blanket as well as the cautions and warning of the water heaters owners manual Should you choose to apply an ins
50. r manifold burner assembly by grasping the manifold rotating it to the left to clear the igniter and flame sensor and pulling back Care should be taken when inner door and burner assembly passes through jacket opening that it does not damage any of the electrical wiring see Figure 17 Removing Burner Orifice 1 Burner may be hot Wait until burner has cooled off After noting the position of the condensation drain hole on the top of the burner turn the inner door manifold burner assembly upsidedown Using a Phillips head screwdriver remove and retain the 2 screws attaching the burner to the manifold pipe see Figure 18 amp 19 2 Using a ratchet with 1 2 socket remove the burner s old orifice Note the burner orifices have different threads dependent upon the gas type Orifices for natural gas have right hand threads orifices for L P have leftt hand threads see Figures 18 amp 19 Installing Burner Orifice 1 Using a ratchet with 1 2 socket install the new burner orifice Note the burner orifices have different threads dependent upon the gas type right handed threads for natural gas turn clockwise to install and left handed threads for propane gas turn counter clockwise to install see Figures 18 amp 19 Note Determine whether the orifice is tall or short and DO NOT replace them with each other 2 Care MUST be taken to ensure the burner is installed correctly on the inner door manifold assembly Position th
51. rating Instructions Repair the leak s and repeat this step Upon verifying proper operation of the water heater replace the insulation and outer door BURNER SUPPORT BRACKET LOCATED IN THE CENTRE OF THE CHAMBER STRAIGHT SLOT CURVED SLOT FOR FOR 40 50K 60 75K BURNERS BURNERS WITH WITH OFFSET STRAIGHT MANIFOLD TUBES MANIFOLD TUBES 000000000000000000 A AT OUTER DOOR ELECTRICAL CONNECTIONS Figure 8 GASKET ON INSULATION REAR OF DOOR PAD MOUNTING CLIP 1 EACH SIDE Figure 9 Figure 10 COMBUSTION CHAMBER OPENING FLAME SENSOR AND IGNITER REMOVAL REPLACEMENT FLAME SENSOR AND OR HOT SURFACE IGNITER Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 3 4 Open End Wrench Phillips Head Screwdriver Ratchet with 1 4 socket or 1 4 nutdriver Flashlight Flat Blade screwdriver Removing Inner Door Manifold Burner Assembly 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Remove the outer door from the unit 5 Unplug all the elec
52. remove the entire gas control assembly from the water heater Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required T15 Torx screwdriver Flat blade screwdriver Removing Electronic Control Module 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 20 Turn gas control switch to the OFF position and turn off the gas supply to the unit see Figure 20 Disconnect the electrical power to the water heater from the wall outlet Remove the front Torx screw at the bottom of the gas control valve thermostat as illustrated in Figure 21 Use a flat blade screwdriver to release the two tabs at the top of the gas control valve thermostat and lift the electronic control straight up see Figures 22 amp 23 Disconnect the temperature sensor cable Note When removing the control module from the gas control assembly disengage the pins on the valve module without causing damage Re assemble in the reverse order Note During re assembly align the pins on the valve module to their proper location in the control module without causing damage iil 7 N Figure 20 FRONT TORX SCREW Figure 21 f EN ELECTRONIC CONTROL LIFT
53. ressure build up 1 Use a pressure reducing valve and relief valve 2 Heater stacking 2 Lower the thermostat setting DRIP FROM RELIEF 3 Closed water system 3 See Thermal Expansion Section in the VALVE 4 Improperly seated valve Manual 4 CheckRelief valve for proper operation Do Not plug T amp P valve GAS CONTROL 1 Defective gas control 1 Replace gas control thermostat THERMOSTAT FAILS TO thermostat SHUT OFF 1 Sulfides in water supply 1 See Smelly water section in the Manual 1 Filling the new water heater for 1 Normal operation the condensation should the first time disappear after heater warms up 2 Moisture from the products of 2 Normal operation the condensation should CONDENSATION combustion disappear in time 3 Water dripping from blower 3 Provide drip TEE to the horizontal section of assembly exhaust vent close to blower assembly 4 Undersized water heater 4 Install adequate heater 1 Insufficient secondary air 1 Provide fresh air ventilation to the water heater 2 Flue clogged 2 Clean locate source and correct COMBUSTION ODORS 3 Heater installed in a confined 3 Provide fresh air ventilation to the water heater area 4 Provide fresh air ventilation to the water heater 4 House too tight 36 PROBLEM POSSIBLE CAUSE S CORRECTIVE ACTION SMOKING AND CARBON FORMATION UNABLE TO LIGHT THE BURNER SIZZLING RUMBLING NOISE WATER LEAKAGE BLOWER WILL NOT START BLOWER RUNS CONTINUOU
54. ring 7 Accessing the blower wheel through the outlet use the paint brush to brush off the outer edge of the blower wheel to dislodge the dirt stuck on the blades and the inside of the housing Rotate the wheel until all blades are clear Note The wheel is a balanced component Do not bend dent or distort the blades as this can upset the wheel balance and affect the blower operation Vacuum out the loosened dirt 8 Accessing the inside of the blower wheel through the rear of the housing gently brush off the inside of the blades using the toothbrush Again take care not to distort the blades Rotate the wheel until all blades are cleaned and vacuum the debris 9 Inspect the flue collector hood still attached to the heater and vacuum out the dust and debris that may have accumulated 10 With all parts cleaned and the blower wheel turning freely reinstall the blower to the mounting plate aligning the 4 studs and pushing tight against the mounting plate 11 Reinstall the 4 11 32 nuts and tighten securely All 4 nuts must be in place and secure to safely operate the blower 12 Reattach the vent piping and coupling to the top of the blower tighten the bottom gear clamp and ensure the piping is secure 13 With all components clean and secure reconnect the electrical power to the heater 14 Reset the thermostat to the desired temperature setting and turn the gas control switch back to the ON position Note If the wat
55. rrect placement Care must be taken so as to not damage any electrical wiring or components as you are installing the new inner door manifold burner assembly Extra caution should be taken to ensure that electrical wiring fiberglass insulation or any other object is not between door gasket and combustion chamber shield Note If the burner door gasket see Figure 9 is worn or damaged it needs to be replaced See section Door Gasket Replacement 8 ELECTRICAL CONNECTIONS MANIFOLD TUBE NUT HEX HEAD SCREWS NOTE OUTER DOOR AND INSULATION NOT SHOWN FOR CLARITY Figure 7 Re installing Inner Door Manifold Burner Assembly 1 Insert the manifold burner assembly in the burner chamber compartment making sure that the tip of burner manifold tab engages in the proper slot of the bracket see Figure 8 Important The tip end ofthe burner manifold MUST be placed in the upper slotted portion for models with input rate of 40 000 to 50 000 Btu hr to obtain proper installation The tip end of the burner manifold MUST be placed in the lower slotted portion for models with input rate of 60 000 to 75 000 Btu hr to obtain proper installation After confirming no materials of any type are between door gasket and combustion chamber shield align the screws on the inner door with the screw holes on the combustion chamber and tighten with 1 4 nutdriver or 1 4 socket amp ratchet see Figure 7 After tightening the inner do
56. s installed between the check valve and the water heating system The expansion tank is installed between the PRV and the water heating system Follow the manufacturers instructions for installing the expansion tank Run the thermal expansion check again The pressure should increase only slightly then hold steady throughout the recovery cycle The expanded water is flowing back from the heater and into the pressurized storage bladder of the expansion tank Air pressure will force this water out of the expansion tank into the supply once usage resumes DO NOT DEPEND ON THE TEMPERATURE amp PRESSURE VALVE T amp P VALVE TO HANDLE THERMAL EXPANSION The T amp P valve manufacturers designed the valve to be an emergency relief device only The T amp P Valve could be subject to reduced effectiveness or failure Thermal expansion of water if not compensated for in system design will lead to the early failure of components These failures are not covered by the manufacturer s warranty so it is extremely important that everyone be aware of the causes symptoms and solutions to thermal expansion in a closed water heating system SYMPTOMS CAUSE THE FIX GENERAL NOTES LEAKING TEMPERATURE AND PRESSURE RELIEF VALVE Water seeping around the relief valve tank connection Leakage at the threaded portion of the relief valve connection Intermittent weeping and or dribbling from the relief valve Large volume of hot water sporadically disch
57. se for natural gas counter clockwise for L P Upon tightening with the fingers and confirming it has not been cross threaded tighten nut with an 3 4 open end wrench see Figure 11 Reconnect all the electrical connections to the bottom of the gas control valve thermostat gently pushing each connector up until it snaps into place see Figures 10 amp 11 Reconnect the electrical power to the water heater in the wall outlet and turn the main gas supply back ON to the gas control valve thermostat Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater As the burner is heating view flames through viewport test the manifold tube connection at the gas control valve thermostat by brushing on an approved noncorrosive leak detection solution Important Do Not splash the solution onto any electrical connections If a leak is detected shut the water heater down by following the directions on the Lighting and Operating Instructions Repair the leak s and repeat step 6 above Upon verifying proper operation of the water heater reinstall the insulation and the outer door Note The structure of flame sensor hot surface igniter allows you to remove and replace them separately CONNECTIONS MANIFOLD TUBE NUT HEX HEAD SCREWS NOTE OUTER DOOR AND INSULATION NOT SHOWN FOR CLARITY Figure 11 BURNER SUPPORT STRIGHT SLOT F
58. setting that satisfies your hot water needs a means such as a mixing valve should be used at the hot water taps used by these people or at the water heater Mixing valves are available at plumbing supply or hardware stores Follow manufacturer s instructions for installation of the valves Using the lowest hot water temperature that meets your needs will also provide the most energy efficient operation of the water heater Never allow small children to use a hot water tap or to draw their own bath water Never leave a child or handicapped person unattended in a bathtub or shower Note A water temperature range of 120 F 140 F 49 C 60 C is recommended by most dishwasher manufacturers Settings Temperature range on residential gas water heater is from 110 F 10 to 155 F x10 and a 70 F vacation setting The T amp P valve will open at 195 F 10 The water heater temperature adjusting dial see Figure 3 was factory set at the lowest temperature all the way counter clockwise to the mechanical stop unless specified differently by provincial or state regulations It is adjustable and must be reset to the desired temperature setting to reduce the risk of scald injury Turning the dial clockwise will increase the temperature and counter clockwise will reduce the temperature The HOT marking on the Honeywell gas valve is indicative of approximately 120 F 49 C and is the preferred starting point Some states have a requireme
59. surize the water tank 5 Connect a hose to the drain valve and terminate it to adequate drain or to the exterior of the building Open the drain valve and allow at least 5 gallons of water to drain from the tank Close drain and remove hose 6 Remove and retain the anode cap on top of the heater and remove and retain just enough insulation so you can access to the anode head see Figure 4 Keep in a safe place for reinstallation later 7 Remove the anode rod by using a ratchet and a 1 1 16 socket turning counter clockwise see Figure 4 1 2 Use Teflon tape or an approved pipe sealant on threads of the new anode rod Place the anode rod in the spud top of the tank and turn clockwise until the threads are hand tight Using a ratchet and 1 1 16 socket tighten down water tight Turn the main water supply back on Open a nearby hot water faucet to purge air from the water line Fill water heater tank completely Note To assure the water heater tank is full keep the hot water faucet open for 3 minutes after a constant flow of water is obtained After turning off the hot water faucet check for water leaks around anode rod and immediately correct any if found Reinstall the insulation and anode cap which were removed in step 6 above Reconnect the electrical power to the water heater in the wall outlet and turn the main gas supply back ON to the gas control valve thermostat Turn the gas control switch to the ON
60. t Detected three second pause Fight Font Fash Valve Fault Detected three second pause Indefinite follow defined procedure to restart three second pause Flammable Vapor Indefinite follow defined Sensor Lockout procedure to restart Six Three Flash three second pause Hardware Fault Indefinite clear fault to restart Six Four Flash three Lockout in 15 seconds or less second pause 38 This page intentionally left blank May be used for notes or to record other installation information 39
61. the mounting clips located on each side of the opening Replacing The Door Gasket 1 2 Remove the paper cover on the new door gasket This will expose the gasket adhesive Position the gasket on the freshly cleaned door surface so that the adhesive firmly holds the gasket to the door Smooth the gasket to avoid creases Re installing Inner Door Manifold Burner Assembly 1 Insert the manifold burner assembly in the burner chamber compartment making sure that the tip of burner manifold tab engages in the proper slot of the bracket see Figure 8 Important The tip end of the burner manifold MUST be placed in the upper slotted portion for models with input rate of 40 000 to 50 000 Btu hr to obtain proper installation e The tip end of the burner manifold MUST be placed in the lower slotted portion for models with input rate of 60 000 to 75 000 Btu hr to obtain proper installation After confirming no materials of any type are between door gasket and combustion chamber shield align the screws on the inner door with the screw holes on the combustion chamber and tighten with 1 4 nutdriver or 1 4 socket amp ratchet see Figure 7 After tightening the inner door screws visually inspect area around door gasket and skirt for spaces or gaps The door gasket MUST be sealed completely in order for the water heater to perform properly DO NOT OPERATE THE WATER HEATER IF THE DOOR GASKET DOES NOT CREATE A SEAL BETWEEN MA
62. tion box opening and place the blower on top of the water heater 2 Reconnect the power connector and the ground connector Reinstall the junction box cover and screw removed in step 5 above Tighten with 1 4 nutdriver or 1 4 socket amp ratchet 3 Align the screw holes on the blower assembly with those on the top of the heater Using the six screws removed in step 6 above install the blower assembly and tighten with 1 4 nutdriver or 1 4 socket amp ratchet see Figure 28 4 Reinstall the vent by pushing it into the adaptor After confirming the ventis properly seated in the adaptor use a 5 16 nutdriver to tighten the screw on the gear clamp of the adaptor connecting the venting to the blower Important This connection must be properly sealed to prevent the leakage of the products of combustion into the living area 24 5 Reconnect the electrical power to the water heater in the wall outlet and turn the gas supply back ON to the gas control valve thermostat 6 Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater Note This power vent heater will accept a 2 or 3 rubber outlet coupling depending on the size of the water heater This coupling mounted in the vertical position accepts the vent piping and is attached as shown in Figure 28 Refer to the Manual to determine vent pipe sizing for your application Th
63. tom of the gas control valve thermostat gently pushing each connector up snapping into place see Figures 10 amp 26 Turn on the gas supply to the unit and test the gas supply line and union connections by brushing on an approved noncorrosive leak detection solution Note Do not splash the solution on control If a leak is detected shut the water heater down by following the directions on the Lighting and Operating Instructions Repair the leak s and repeat leak test Reconnect the electrical power to the water heater in the wall outlet and turn the gas supply back on to the gas control valve thermostat Restart the water heater by following the directions on the Lighting and Operating Instructions label located on the front of the water heater As the burner is heating view flames through viewport test the manifold tube connection at the gas control valve thermostat by brushing on an approved noncorrosive leak detection solution Important Do Not splash any solution onto any electrical connections Upon verifying proper operation of the water heater replace the outer door CONNECTIONS m 17 aa a 1 WU Ls a Figure 27 MANIFOLD TUBE NUT 23 BLOWER REMOVAL REPLACEMENT BLOWER Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools req
64. trical connections from the bottom of the gas control valve thermostat see Figure 11 6 Using a 3 4 open end wrench remove the manifold tube from the gas control valve thermostat turning counter clockwise for natural gas clockwise for L P Grasp the manifold tube and push down slightly to free the manifold tube from the gas control valve thermostat see Figure 11 7 Remove the insulation pad on the inner door by cutting it if necessary Keep the insulation in a safe place for reusing it later 8 Use a 1 4 nutdriver or 1 4 socket amp ratchet to loosen the 2 hex head screws on the inner door so the inner door manifold burner assembly can be removed see Figure 11 9 Remove inner door manifold burner assembly by grasping the manifold rotating it to the left to clear the igniter and flame sensor and pulling back Care should be taken when inner door and burner assembly passes through jacket opening that it does not damage any of the electrical wiring see Figure 13 Removing Flame Sensor And Or Hot Surface Igniter Note The configuration of the flame sensor and igniter allows you to replace them separately It is recommended to clean the flame sensor when you replace the igniter 1 Lift the retainer clip straight up from the back of the manifold component block using a flat blade screwdriver then remove the manifold component block from the manifold door see Figure 14 2 Disconnect the wiring connection between
65. uble the more you heat the more lime comes out higher usage excessive hardness and increased heating surface can lead to a high incidence of limed up heaters Symptoms often include a popping of water trapped under lime deposits or the sizzling of water trapped next to elements boiling it to steam Treatment of a limed up heater is relatively simple Since CaCO is a base the easiest way to dissolve it so it can be flushed from the heater is with an acid The most commonly used is phosphoric acid at a food grade level Two available treatments are Mag Erad and Un Lime Any well stocked plumbing supply house should have a deliming solution available The directions on the product should be followed explicitly SYMPTOMS CAUSES THE FIX CONDENSATION The water heater appears to be releasing water while the main burner is on or water is found surrounding the heater shortly after the water heater has been used This section explains why flue gases condense and how you can differentiate between condensation and leaking Condensate is the result of air borne water vapor being chilled below the dew point The dew point is the temperature at which water vapor turns into liquid Low incoming water temperatures cool the piping and the heat transfer surfaces of the water heater When the main burner comes on the hot flue gases turn into condensate upon contact with these surfaces The typical home water heater will produce about one half g
66. uired Ratchet with 5 16 socket or 5 16 nutdriver Ratchet with 1 4 socket or 1 4 nutdriver Removing Blower 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn OFF the gas supply to the unit see Figure 3 3 Disconnect the electrical power to the water heater from the wall outlet 4 Use a 5 16 nutdriver to loosen the screw on the upper gear clamp of the rubber coupling adaptor connecting the venting to the blower Slowly pull the vent from the adaptor see Figure 28 Note The rubber coupling adaptor will be different based on the venting size 2 or 3 vent pipe 5 Usea 1 4 nutdriver or 1 4 socket amp ratchet to loosen the screw on the junction box Remove and retain the screw and junction box cover Disconnect the power and ground connectors see Figure 28 6 Usea 1 4 nutdriver or 1 4 socket amp ratchet to loosen remove and retain the 6 hex head screws so the blower assembly can be removed Remove the blower while carefully passing the power and ground connectors through the junction box opening see Figure 28 Important When removing the blower care must be taken to pass the power and ground connectors through the junction box opening so the wires and blower do not get damaged Installing Blower 1 Pass the power and ground connectors through the junc
67. ulation blanket to this heater you should follow these instructions Failure to follow these instructions can restrict the air flow required for proper combustion resulting in fire asphyxiation serious personal injury or death Do not cover the outer door thermostat or temperature amp pressure relief valve When installed the insulation blanket will cover important safety and operation labels Obtain new warning and instruction labels from the Technical Information Center listed in the owners manual The replacement labels must be placed on the blanket in the location of the original labels on the water heater jacket Do not cover the instruction manual Keep it on the side of the water heater or nearby for future reference Do not apply insulation to the top of the water heater as this will interfere with safe operation of the draft hood Do not allow insulation to come within 2 of the rear air duct of the water heater to prevent blockage of combustion air flow to the burner The combustion air openings in the rear air duct of the water heater must NOT be obstructed Inspect the insulation blanket frequently to make certain it does not sag thereby obstructing combustion air flow 35 TROUBLESHOTING CHART BURNER FLAME TOO 1 Insufficient secondary air 1 Provide ventilation to water heater HIGH 2 Orifice too large 2 Replace with correct orifice 1 Low gas pressure 1 Check with gas utility company FLAME BURNS AT 2 Defective gas c
68. ule from the gas control assembly disengage the pins on the valve module without causing damage 5 Remove the Valve Module as outlined in Removing Valve Module section above 6 Use a screwdriver to pry under the sensor retainer finger to remove the temperature sensor and cable see Figure 25 7 Re assemble in the reverse order Note When replacing the valve do not apply pressure with the hand on the valve pins Note During re assembly align the pins on the valve module to their proper location in the control module without causing damage SENSOR RETAINER FINGER NOTE USE CAUTION WHEN REPLACING THE VALVE TO NOT APPLY PRESSURE ON THE VALVE PINS Figure 25 TEMPERA TURE SENSOR CABLE UNDER THE RETAINING TAB THREADED CONTROL FITTING DO NOT REMOVE FROM WATER HEATER 21 GAS VALVE REMOVAL REPLACEMENT GAS CONTROL VALVE Important Use only factory authorized replacement parts If you lack the necessary skills to properly perform the installation you should not proceed but get help from a qualified service technician Tools required 3 4 Open End Wrench short length of 1 2 threaded pipe Pipe Wrench Removing Gas Control Valve 1 Set the gas control valve thermostat to its lowest setting by turning the knob counter clockwise to the VAC point see Figure 3 2 Turn gas control switch to the OFF position and turn off the gas supply to the unit see Figure 3 3 Dis
69. ved in step 1 of Removing Burner install the new burner to the inner door manifold assembly rotate the assembly to visually check the top portion of the burner assembly and confirm the orientation of the condensation drain hole see Figure 19 and note Caution Must Be Taken Prior to installing the new inner door manifold burner assembly look inside the burner chamber to fully understand the correct positioning of the burner assembly and burner manifold tab It may be necessary to use a flashlight to ensure correct placement Care must be taken so as to not damage any electrical wiring or components as you are installing the new inner door manifold burner assembly Extra caution should be taken to ensure that electrical wiring fiberglass insulation or any other object is not between door gasket and combustion chamber shield Note If the burner door gasket see Figure 9 is worn or damaged it needs to be replaced See section Door Gasket Replacement Reinstalling Inner Door Manifold Burner Assembly 1 Insert the manifold burner assembly in the burner chamber compartment making sure that the tip of burner manifold tab engages in the proper slot of the bracket The tip end of the burner manifold MUST be placed in the slotted portion under the condensation pan to obtain proper installation see Figure 16 Important The tip end of the burner manifold MUST be placed in the upper slotted portion for models with input rat

Download Pdf Manuals

image

Related Search

Related Contents

PDF User Manual  SL-912i-912-914-006 R1 Version Française  Manual del servicio de certificación con clave  MANUEL D`UTILISATION TRONÇONNEUSE CS-3700ES  The National Statistics Socio-economic Classification User Manual  membrete autorizado - Delegación Cuauhtémoc  Service Manual  Canon DR-7090C All in One Printer User Manual  LED Projector  BOXCOOL専用温度センサ取扱説明書 例、  