Home

Model: PF1103T TIME CONTROL WITH FREEZE PROTECTION

image

Contents

1. Replace t stat when temp is below 32 deg Defective relay Replace relay Defective wiring Check wiring 158 00859 indd 2 D 4 7109 2 00 13 PM
2. b mailing the product along with proof of purchase postage prepaid to the authorized service center listed below This warranty is made by Intermatic Incorporated After Sales Service 7777Winn Rd Spring Grove Illinois 60081 9698 815 675 7000 http www intermatic com Please be sure to wrap the product securely to avoid shipping damage INTERMATIC INCORPORATED SPRING GROVE IL 60081 9698 158 00859 4 158 00859 indd 1 Do not use this control as a power disconnect it could turn ON unexpectedly Disconnect electricity at the main Panel before servicing this control or the equipment s connected to it GENERAL INFORMATION Model PF1103T Freeze Protection Control is self contained in an indoor outdoor beige rainproof enclosure and designed to automatically control as well as protect the Pool Spa equipment and plumbing against freeze damage The Control if wired according to instructions turns ON OFF the Filter Pump on a daily schedule and also turns ON the Filter Pump when the air temperature where this Control is located drops below the temperature set by the ther mostat dial between 33 F and 42 F Nevertheless the Control is not intended to be a substitute for insulation coverings or maintenance Both models are designed to operate either on 120 Volt or 240 Volt 60 cycle When used on 240 Volt however the neutral wire must be installed and it is not recommended for controlling 240 Volt GFCI protected eq
3. conduit run s required by duit about 10 inches long installed at bottom of the the installation layout enclosure Handle capillary tube with care 2 Hang enclosure on a flat vertical surface or other 6 TEST INSTALLATION support using hardware suitable for the a Turn thermostat dial to its lowest setting and purpose place crushed ice in plastic bag inside 3 Properly terminate conduits at both ends and pull in capillary coil of Thermostat the conductors Min 75 C Rated as b Turn power ON to Control wait one minute specified by the installation layout then slowly turn thermostat dial counter 4 Select the appropriate wiring diagram 120V or clockwise until Filter Pump starts 240V installation on page 4 of this manual and make c Turn power OFF to Control remove ice LINE and LOAD Pump connections as shown First check wiring reinstall front plate 1 Insert ON green and OFF red trippers into dial at desired ON and OFF times Fig 1 2 Be sure trippers are firmly pressed against dial surface and at least one space is left between ON and OFF trippers Fig 2 3 Turn dial clockwise one or more revolutions until correct time of day is next to arrow in center of dial Fig 3 TIME OF DAY Figure 3 The knob in the upper left corner of timer is for operating the Filter pump manually when needed By turning it COUNTERCLOCKWISE it will start or stop the filtering neating cycle ahead of the schedule
4. WIRING DIAGRAMS INTERNAL WIRING CLOCK MOTOR YELLOW To 240V PUMP SUPPLY To 120V PUMP NTERMATIC PF1100 SERIES INSTALLATION OPERATION amp FREEZE PROTECTION CONTROLS SERVICE MANUAL Model PF1103T TIME CONTROL WITH FREEZE PROTECTION IN RAINPROOF TYPE 3R ENCLOSURE Model PF1103MT TIME CONTROL MECHANISM ONLY WITH FREEZE PROTECTION SUITABLE FOR POOL SPA EQUIPMENT CONTROL INPUT VOLTAGE 120 VOLT 60 HZ OR 240 VOLT 60 HZ ELECTRICAL RATING 1 5 HP 120 VOLT AC 3 HP 240 VOLT AC Risk of drowning Do not permit unsupervised children to use pool or spa Close supervision of children required at all times 240 VOLT WIRING 1 NEUTRAL MUST ALWAYS BE WIRED MN BLACK LINE 1 on Se GROUND MLB IPED LINE 2 BLUE LOAD 1 J WHITE NEUTRAL FE YELLOW LOAD 2 OAD 120 VOLT WIRING 1 RED AND YELLOW WIRES ARE NOT USED MUST BE PERMANENTLY INSULATED CAPED MM BLACK LINE 1 Fa GREEN GROUND ELEL RED LINE 2 BLUE LOAD 1 C WHITE NEUTRAL FE YELLOW LOAD 2 Risk of electric shock 4A WARNING Test ground fault protection regularly If it fails do not use Pool or Spa Contact qualified service professional for help re we WU a gt ONE YEAR LIMITED WARRANTY If within one 1 year from the date of purchase this product fails due to a defect in workmanship Intermatic Incorporated will repair or replace it at its sole option free of charge This warranty s extended to
5. d start stop time Automatic operation will resume with the next scheduled cycle Timer comes with two sets of trippers allow Manual Knob ON Tripper Green 5 43 Oia a TIME OF DAY YINTeRMatic HEAVY DUTY OFF Tripper Red To suspend automatic operation remove red and green trippers from Dial and Store them in a convenient place Additional trippers can be obtained by con tracting an Intermatic distributor or Intermatic Consumer Service at 815 675 7000 and ask ing for 156PB10398A tripper kit 2 ON and 2 OFF trippers identify each lead by color The LINE connections for d Turn power ON to Control and set Timer 240 Volt supply are Black and Red To operate the and the Thermostat see OPERATION clock motor and relay coil you also have to connect instructions on page 3 ing the choice of two cycles per day If only one cycle is needed the extra trippers may be stored on the dial by placing SAME color trippers next to each other TROUBLESHOOTING Timer will not keep time the NEUTRAL to the White lead NOTE If the 240 Volt supply is GFCI protected Stop This is not the right control for such applications Use Model PF1102T INSTALLATION MODEL PF1103MT instead Otherwise connect pump to Blue and Yellow leads Make sure the installation is properly grounded 5 If the Control is installed in location where it i 1 Astal mechanism in any Intermatic Pool Panel with exposed to direct sun most of th
6. e day extend 8 inches ONIy one Time Switch by snapping it into the unused of the copper capillary tube of the mounting bracket furnished with the Panel No trippers on dial Install trippers Trippers are not installed properly Re install trippers on dial Timer dial is not turning Breaker OFF Turn ON Power Timer motor dead due to lightning Replace timer SETTING OPERATING INSTRUCTIONS TO SET FILTER TIMER follow instructions on page 3 The length of the daily filtration heating cycle depends on many variables such as size shape and geographic location of the pool water chemistry type of pool equip ment usage and season of year If not sure contact your local pool service professional for advice Pump operates off schedule Power failure earlier Reset timer Breaker was OFF for some time Reset timer Filter pump is ON at all timer Timer contacts welded Replace timer TO SET THERMOSTAT turn dial to desired temperature between 33 F and 42 F Remember many variables such as the location of this Control the location of the pool or spa the location and insulation of the plumbing etc must be considered before selecting the turn ON temperature of the Filter Pump Your local pool service professional is the best source of information The Thermostat is factory set to turn OFF the Filter Pump when the ambient temperature rises 5 F above its set point Filter Pump will not start Defective thermostat see Test procedure
7. the original household purchaser only and is not transferable This warranty does not apply to a damage to units caused by accident dropping or abuse in handling acts of God or any negligent use b units which have been subject to unauthorized repair opened taken apart or otherwise modified c units not used in accordance with instructions d damages exceeding the cost of the product e sealed lamps and or lamp bulbs LED s and batteries f the finish on any portion of the product such as surface and or weathering as this is considered normal wear and tear g transit damage initial installation costs removal costs or reinstallation costs INTERMATIC INCORPORATED WILL NOT BE LIABLE FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES SOME STATES DO NOT ALLOW THE EXCLUSION OR LIMITATION OF INCIDENTAL OR CONSEQUENTIAL DAMAGES SO THE ABOVE LIMITATION OR EXCLUSION MAY NOT APPLY TO YOU THIS WARRANTY IS IN LIEU OF ALL OTHER EXPRESS OR IMPLIED WARRANTIES ALL IMPLIED WARRANTIES INCLUDING THE WARRANTY OF MERCHANTABILITY AND THE WARRANTY OF FITNESS FOR A PARTICULAR PURPOSE ARE HEREBY MODIFIED TO EXIST ONLY AS CONTAINED IN THIS LIMITED WARRANTY AND SHALL BE OF THE SAME DURATION AS THE WARRANTY PERIOD STATED ABOVE SOME STATES DO NOT ALLOW LIMITATIONS ON THE DURATION OF AN IMPLIED WARRANTY SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU This warranty service is available by either a returning the product to the dealer from whom the unit was purchased or
8. uipment For such application use Model PF1102T Time Control with Freeze Protection Model PF1103MT is a mechanism only functions just like Model PF1103T and fits snaps into any Intermatic Pool Panel Models T10000R T30000R or T40000R Series 4 7 09 2 00 12 PM CAUTION Risk of injury or property damage Do not install or operate this equipment and other associated equipment without basic safety precautions Read and follow the safety instructions listed below and other basic safety precautions before installation or operation of this control and other associated equipment 1 This control must be installed by a qualified person according to the national and local electrical codes Install this control not less than 5 feet 3 meters in Canada from inside edge of pool and 1 foot 30cm above ground USE COPPER CONDUCTORS ONLY rated 75 C minimum Do not exceed maximum ratings of individual components wiring devices and current carrying capacity of conductors For control grounding bonding installing and the wiring of underwater lights refer to Article 680 of the National Electrical Code or Article 68 of the Canadian Electrical Code The control should not operate any equipment which would cause bodily injury or property damage should it be activated unexpectedly INSTALLATION 1 Select the proper outdoor location for the Control thermostat into an open ended plastic or metal con and prepare the necessary