1. 1L591 NC150R Wiring Rev5 100510 1 Copyright TekTone Sound amp Signal Mig Inc All Rights Reserved IL591 Tek SAFE Area of Rescue Assistance Manual 5 System Maintenance Instructions Most of the equipment and parts used in the NC150R Area of Rescue Assistance System are not user serviceable and cannot be replaced or repaired by the end user Equipment must be repaired by qualified service personnel only There are no user serviceable parts in the PKISIA and PK152 Power 8 Control Units or the IR150B IR150N IR150SS IR150SS S Remote Call Stations notify qualified service personnel for repair or replacement Parts which are user serviceable are listed in the following section and their replacement explained NC150R Master Stations There are several user serviceable parts in the NC150R Master Stations Only one of these parts is electrically operated The user serviceable parts and replacement procedures are explained below Refer to Figure 6 to identify replacement switch parts A full list of replacement parts and numbers appears in the Replacement Parts section Selector Lamp Switch Lens Replacement e Remove lens by squeezing top and bottom together and pulling away from panel e Replace with same color lens by pushing new lens towards panel The lens should snap into place on the selector lamp switch knob with a noticeable click Selector Lamp Switch Filter Identification e Remove lens by squ
2. Lens 1 each NC150R Button not used 6 IL591 Tek SAFE Area of Rescue Assistance Manual Copyright TekTone Sound amp Signal Mig Inc All Rights Reserved Copy this Users Guide and place it next to the NC150R Master Station This page will fit in a standard 8 x10 frame when cut on the dotted lines IL591 Page 7 Rev 12 03 2011 Teklone Users Guide for Tek SAFE Area of Rescue Assistance System NC150R Master Station IR150SS IR150SS S Remote Call Station IR150B Remote Call Station Qr 00000000 00000000 o0o000000 00000000 00000000 ooo0o0000 PUSH FOR HELP 6 7 4 5 Call Button Tone call to selected remote when pressed Call Lamp Indicates incoming call when illuminated Talk Button Talk when pressed Listen when released IR150N Remote Call Station Selector Buttons Establishes conversation path with associated remote station when depressed Selector Lamps Indicates incoming call from associated remote when illuminated illuminated Call Button Places a call when pressed Call Placed Lamp Indicates a call is placed when Reset Button Cancels the call when pressed In Use LED Indicates station is in use when illuminated Audio On Lamp Indicates master station is listening when illuminated NC150R MASTER STATION OPERAT
3. TALK button while speaking and release to listen The remote area may be monitored by selecting the remote station and releasing the TALK button When conversation or monitoring is complete press the station selector button to release it The remote station s in use LED will turn off Test Station Selector Lamps Press TEST button All station selector lamps should illuminate Improper Operation If the NC150R Master Station fails to operate as described contact qualified maintenance personnel There are no user replaceable parts on the NCISOR Master Stations other than the station selector lamps IR150B IR150N IR150SS IR150SS S Remote Call Stations Refer to Figure 1 for locations names and functions of controls and indicators Call the NCISOR Master Station Press the CALL button The call placed lamp will illuminate to indicate call placement When the call is answered the call placed lamp will go off and the in use LED will illuminate to indicate a communication path has been established to the master station Speak in a normal voice Cancel a Call Press the RESET or CANCEL button Call placed lamp will go off Improper Operation Contact qualified service personnel if the station does not operate as described There are no user serviceable parts on the IR150B IR150N IR150SS IR150SS S Remote Call Stations Copyright TekTone Sound amp Signal M g Inc All Rights Reserved IL591 Tek SAFE Area of Rescue Assista
4. liability for any errors or inaccuracies that may appear in this documentation TekTone the TekTone logo Tek Call Tek Care Tek Check In Tek Com Tek Digicare Tek Door Tek Entry IH Tek Guard Tek Micro Tek Micro II Tek MMARS Il TekNIOS TekNIOS II Tek Paging Tek Phone Tek Safe Tek Select II Tek Sentry Tek Sound Tek Status Tek Trio and Tek View are either registered trademarks or trademarks of TekTone Sound amp Signal Mfg Inc in the United States and or other countries All other trademarks are the property of their respective owners ii e IL591 Tek SAFE Area of Rescue Assistance Manual Copyright TekTone Sound amp Signal Mig Inc All Rights Reserved Table of Contents System Operating Instructions unnsuunsennennnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnnn 1 NCISOR Master Station rra 1 IR150B IR150N IR150SS IR150SS S Remote Call Stations oe eee 1 system Installati n 2 een 3 Installation Procedure cel a Augen cours 3 Equipment Locations Braun lignan eens 3 NCISOR Master Station ia nenne 3 IR150B IR150N IR150SS IR150SS S Remote Call Stations 3 PK151A PK152 Power amp Control Units cccccccccccnonocinininanananannnnnnnnnnoncnnncnnnnos 3 Wirng Install tion wu tities eine heel Benannte a ee ee 3 Housing Installation sii ii 3 NGISOR Master Station rn arena nee 3 IR150B Remote Call Stations u22us00ssesnensnennensnennnnnennnennennnennenn
5. mounted in areas that are exposed to weather effects outdoors but under an overhanging roof but not in areas directly exposed to weather driving rain with no coverage PKI151A PK152 Power amp Control Units Locate the PK151A or PK152 and the SS106 within an IH151N Junction Box in an accessible area The junction box transformer and power amp control unit are also available preassembled from the factory as part number IH151NK Do not exceed operating temperature range of 10 30 C Location should provide for convenient cable runs to remote call and master stations Cable run from the PK151A or PK152 to the NCI50R Master Station must not exceed 100 Wiring Installation The necessary wiring information can be found in Figure 7 Run wiring conduit from remote call station to remote call station and terminate at the PK151A or PK 152 Power amp Control Unit Limit each run to 16 stations and 600 feet of wire Housing Installation NCI50R Master Station To flush wall mount provide wall cutout as shown in Figure 2 Remove panels from frame as shown in Figure 3 Fit back box and frame assembly into prepared opening Fasten assembly into place using screws provided in back box Hous ing must be TekTone OH150 Replace panels using the procedure as shown in Figure 3 IR150B Remote Call Stations Install the back box Steel City H3BD with Steel City 3GC plaster ring or exact equivalent as shown in Figure 4 for each station in system I
6. ION Answer a Call Normal calls are indicated by simultaneous operation of the following signals Steady illumination of the associated station selector lamp which is marked to indicate call origin steady illumination of call lamp and slowly pulsing audible tone To establish conversation with the calling station press the associated station selector button The remote station s in use LED will illuminate To speak to the caller press the TALK button while speaking and release to listen When the conversation is complete press the associated station selector button to release the station The remote station s in use LED will turn off Call a Remote Call Station Locate the station selector button associated with the remote station to be called Press that selector button to establish a conversation path The remote station s in use LED will illuminate To produce an announcing tone at the remote station press the TALK and CALL buttons simultaneously Press the TALK button while speaking and release button to listen The remote area may be monitored by selecting the remote station and releasing the TALK button When conversation or monitoring is complete press the station selector button to release it The remote station s in use LED will turn off Test Station Selector Lamps Press TEST button All station selector lamps should illuminate IR150B IR150N IR150SS IR150SS S REMOTE STATION OPERATION Call the NCI
7. SOR Master Station Press the CALL button The call placed lamp will illuminate to indicate call placement When the call is answered the call placed lamp will go off and the in use LED will illuminate to indicate a communication path has been established to the master station Speak in a normal voice Cancel a Call Press the RESET or CANCEL button Call placed lamp will go off
8. TALK button on the master station An electronic call tone should be heard at the master station and at the remote call station Press the TALK button and speak in a normal voice Release the button to hear the reply At the remote call station the call placed lamp should turn off and the in use LED should be illuminated When voice communication is heard reply in a normal voice Return all controls to the normal position Figure 7 Tek SAFE System Wiring Diagram Notes 1 Terminal identifications shown are not in actual order 2 Main supply circuit Connect to 117 VAC 60Hz 40 Watts maximum Use 18 gauge wire 3 Use shielded cable if not in a metal conduit If shielded cable is used shield drain wire NC150R Master Panel replaces conductor connected to terminal C on CONTROL module on NC150R Connect shields from twisted shielded pairs to C terminal on master 18 IR150B IR150N A IR150SS IR150SS S 2 Yellow R Brown P 2 Blue C Orange L Red Y Green X PK151A PK152 IR150B IR150N Typical of up to 8 IR150SS IR150SS S stations maximum Yellow R Brown P Blue C Orange L Red Y Green X Selector Switch Module Selector Switch Module XLXLXLXL y D R R P P TI T2 aN N Q Q JE y 1 Twisted n n 117 VAC Shielded Pair 22 A Twisted Shielded Pair 22
9. Teklone SOUND amp SIGN Communications for today and tomorrow Alpha Communications 42 Central Drive Farmingdale NY 11735 1202 Phone 631 777 5500 Fax 631 777 5599 Website www AlphaCommunications com Email info alphacommunications com TOLL FREE Technical 1 800 666 4800 IL591 SECTION D Rev 12 03 2011 Tek SAFE NC150R Area of Rescue Assistance System Operation Installation and Service Manual The Tek Safe NC150R Area of Rescue Assistance System provides communica tion between area of rescue assistance stations in protected stairwells and the building lobby Calls are indicated at the NC150R Master Station by both visual and audible signals The master station also has sensitive two way communication to the IR150B IR150N IR150SS and IR150SS S Remote Call Stations Tek SAFE meets ADA requirements for area of rescue assistance systems check local codes for additional requirements Operation Installation and Service Manual Copyright 2003 2011 TekTone Sound amp Signal Mfg Inc All rights reserved No part of this publication may be copied without the express written permission of TekTone Sound amp Signal Mfg Inc The content of this manual is furnished for informational use only is subject to change without notice and should not be construed as a commitment by TekTone Sound amp Signal Mfg Inc TekTone Sound amp Signal Mfg Inc assumes no responsibility or
10. eezing top and bottom together and pulling away from panel e Remove white filter by lifting it out of selector lamp switch knob e Identify filter by room number or other means using dry transfer lettering labels or other similar methods Be sure identified filter is replaced in knob so that lettering is readable right side up Defective Lamp Replacement e Remove lens and filter by method described above e Using needle nosed pliers tweezers or similar tool pull lamp out of socket by gripping lamp at sides and moving it from side to side as it is pulled away from the panel WARNING Do not squeeze too tightly or it will break e Replace lamp by holding with tool and pushing into socket Be sure lamp is turned so that the base is lined up with the slot in the socket Lamp must be pushed in below the level of the filter e Push test button to make sure lamp has been placed in socket properly If lamp does not light try pressing more firmly into socket If lamp still does not light repeat steps above with new lamp until one works properly e Replace lens and filter in lamp switch knob as previously described Replacement Parts Part No Description Used For LIO14K 24V Lamp 10 each NCI150R Selector Module Lamps RP021K Blank Filter 10 each NC150R Selector Button Label RP022K Orange Lens l0each NCISOR Call and Selector Buttons RP024 Green Lens each NC150R Talk Button RP027K Clear Lens 10 each NC150R Button not used RP028 Yellow
11. f a smaller back box is desired use ARCO 2GB with ARCO 3GC ring Minimum dimensions of the back box must be no less than 8 6 x4 5 x2 5 Minimum clearance from live parts on the station to dead metal parts must be no less than 0 5 IR150N Remote Call Stations Install a TekTone IH106N back box horizontally for each station in system IR150SS Remote Call Stations Install a TekTone OH600 back box horizontally for each station in system IR150SS S Remote Call Stations No back box is necessary to surface mount PKISIA or PK152 Power Control Unit SS106 24 VAC 30 VA Transformer IHISIN Junction Box Fasten IH151N Junction Box to wall using suitable fasteners Mount PK151A or PK152 inside junction box Minimum dimensions of junction box must be no less than 12 x12 x4 Minimum clearance from live parts to dead metal parts on housing must be 1 Install SS106 Transformer in junction box as shown in Figure 5 Do not connect trans former primary to power source until entire installation is completed and checked for shorts and grounds Install transformer connection box as shown in Figure 5 Minimum dimen Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL591 Tek SAFE Area of Rescue Assistance Manual gt 3 System Installation sions must be no less than 1 75 x3 75 x1 5 The junction box transformer and power amp control unit are also available preassembled from the factory as part number IH151NK Wire Check
12. nce Manual 1 Figure 1 Master and Remote Call Station Control Locations NC150R Master Station IR150SS IR150SS S Remote Call Station IR150N Remote Call Station TekTone Ei Call Button Tone call to selected remote when pressed 8 4 65 Call Lamp Indicates incoming call when illuminated IR150B Remote Call Station Talk Button Talk when pressed Listen when released Selector Buttons Establishes conversation path with associated remote station when depressed Selector Lamps Indicates incoming call from associated remote when illuminated Call Button Places a call when pressed Call Placed Lamp Indicates a call is placed when illuminated N Reset Button Cancels the call when pressed In Use LED Indicates station is in use when illuminated Audio On Lamp Indicates master station is listening when illuminated A E Finished Wall p 11 625 4 4375 11 625 7 4 4375 eS i In masonry walls install 0 5 x4 wood fillers at top and bottom of opening for Wall Opening ur housing attachment Flush Housing Width Height Finished Floor OH150 4 7 16 11 5 8 Figure 3 Panel Removal Figure 4 Ring amp Back Box f
13. nnnnsnnnnennnnnn 3 IRISON Remote Call Stations essen hn nae 3 IR150SS Remote Call Stations 20u2200200nsnennensnennennnennnenennnennennnennnnnnnnnnnnnnn 3 IRISOSS S Remote Call S tations u sense 3 PK151A or PK152 Power amp Control Unit SS106 24 VAC 30 VA Transformer IH151N Junction Box cccccccnnnnnninananananono 3 Wire CheckoUb ota LEER EEE een 4 Wire Connections vectra io EOS 4 Connections ChEckouk esti tata adi 4 System Test Instructions iii en dene eee 4 System Maintenance Instructions cccceseseeeeeeeseeeeeeeeeeneesseneeeeeneeees 6 NGISOR Master Stations cue iia 6 R placement PATIS 8 220808 genen Rasen ues tes cies 7 Frameable Users Guide accio nnmnnn 8 Illustrations Figure 1 Master and Remote Call Station Control Locations 0 0 0 eens 2 Figure 2 Master Panel Housing Chart and Wall Cut Out Details 2 Figure 3 Panel Removal amp Replacement ooononnccicnocnconnnonnnnnonnnonononcnn non ccnn nro nora non ccoo 2 Figure 4 Ring amp Back Box for IR150B Remote Call Stations ene 2 Figure 5 SS106 Transformer Installation ss seesseseesesesesessesesesencseesceeseseerreesesessees 4 Figure 6 NC150R Selector Lamp Switch Lens Filter and Lamp Replacement 4 Figure 7 Tek SAFE System Wiring Diagram eeesensenenenennnnn 5 Copyright TekTone Sound amp Signal Mfg Inc All Rights Reserved IL591 Tek SAFE Area of Rescue As
14. or amp Replacement Panel Removal First IR150B Remote Call Stations remove the self tapping metal screws located in the SS top U channel just above each panel Then lift up on panel to clear bottom channel After removal adequate space is available to grasp and remove the remaining panels Panel Replacement Insert top of panel into top channel push panel in at bottom and release Panel should fall into place in bottom channel Replace self tapping metal screws Install ring with panel mounting holes at top and bottom as shown 2 IL591 Tek SAFE Area of Rescue Assistance Manual Copyright TekTone Sound amp Signal M g Inc All Rights Reserved System Installation Installation Procedure e Determine equipment locations e Install wiring e Install housings e Check wires e Connect equipment e Check connections Equipment Locations NCI50R Master Station Locate NC150R Master Station in building lobby within easy reach of operating personnel Do not exceed operating temperature of 10 30 C IR150B IRISON IR150SS IRI50SS S Remote Call Stations Locate IR150B IR150N IR150SS IR150SS S Remote Call Stations in protected area of rescue assistance loca tions Up to 8 remote call stations are supported by each NC150R Master Station Do not exceed operating temperature range of 10 40 C The IR150SS includes weather stripping and a Mylar speaker for weather resistance and may be
15. out Use an ohmmeter or other continuity checking device to test wires for shorts or grounds If shorts or grounds are encountered find and correct the problem before continuing Make sure minimum number of conductors needed for all of the equipment being used in the system are available Wire Connections Use crimp style connectors for all wire connections Do not use wire nuts NCI50R Master Station Connect wires as shown in Figure 7 IRI150B IRISON IRI50SS IR150SS S Remote Call Stations Connect wires as shown in Figure 7 PKISIA or PK152 Power amp Control Unit Connect wires as shown in Figure 7Also con nect secondary from the SS 106 Transformer 24 VAC 30 VA connections to the PK151A or PK152 as shown in Figure 7 Do not connect transformer primary to power source until entire installation is completed and has been checked for shorts and grounds Connections Checkout Recheck all connections to equipment If all wires and connections are satisfactory connect primary coil of SS106 Transformer to source of 117 VAC 60 hZ 40 watts max and operation of system can be checked according to System Test Instructions System Test Instructions Before proceeding with a system test set all stations to normal conditions as follows NCISOR Master Station All push buttons should be in the out position A depressed button may be released by pressing the button and then releasing it IRI150B IRISON IRISOSS IR150SS S Remote Call S
16. sistance Manual gt 111 System Operating Instructions TM This section provides complete operating instructions for all Tek SAFE functions as well as reference drawings for use in locating and describing all controls System operators must read the following operating instructions concerning system equipment and the terms used in conjunction with the equipment NC150R Master Station Refer to Figure 1 for locations names and functions of controls and indicators Answer a Call Normal calls are indicated by simultaneous operation of the following signals Steady illumination of the associated station selector lamp which is marked to indicate call origin steady illumination of call lamp and slowly pulsing audible tone To establish conversation with the calling station press the associated station selector button The remote station s in use LED will illuminate To speak to the caller press the TALK button while speaking and release to listen When the conversation is complete press the associated station selector button to release the station The remote station s in use LED will turn off Call a Remote Call Station Locate the station selector button associated with the station to be called Press that selector button to establish a conversation path The remote call station s in use LED will illuminate To produce an announcing tone at the remote call station press the TALK and CALL buttons simultaneously Press the
17. tations If the call placed lamp is illuminated press the RESET button to reset it Test IR150B IRISON IR150SS IR150SS S Remote Call Stations Test remote call stations one at a time Press the CALL button on each remote call station to place a call Check for operation of the following signals Figure 5 SS106 Transformer Installation Figure6 NC150R Selector Lamp Switch Lens Filter and Lamp Replacement Lens Filter 24V Lamp Switch Knob 4 IL591 Tek SAFE Area of Rescue Assistance Manual Copyright TekTone Sound amp Signal M g Inc All Rights Reserved System Installation e The call placed lamp on the remote call station should be illuminated e OntheNCIS5O0R Master Station the CALL lamp should be illuminated and the associated station selector lamp marked to identify the calling station should be illuminated A slowly repeating audible call tone should be heard Press the RESET button on the remote call station to reset the call All signals should be canceled Test the Intercom Function Press the CALL button on the remote call station to place a call At the master station select the calling station by pressing the illuminated station selector button and check for the following e The station selector lamp should be canceled e The caLL lamp should turn off e The audible call tone should be canceled The remote call station s in use LED should be illuminated Press the CALL button and the
Download Pdf Manuals
Related Search
Related Contents
CodeCheck Technical Notes - Summer 2003 CB3-111 User Guide Manual - Downloaded from LpManual.com ④Click! ②入力! ③Check! ⑤Click! ①読取! ⑥入力! ⑦選択 Samsung 931BW User Manual Bulletin technique User Manual - san telequip Acronis True Image Home 2012 Leroy-Somer Poulibloc 2000-3000 - Maintenance INSTRUCTION MANUAL Copyright © All rights reserved.