        Digimatic Gage Counter EC-101D
         Contents
1.      Lower tolerance limit    Attribute data     NG  100 ms     NG a      The time varies depending on the gage  the above value  shows a case of LGD      2  External preset HOLD    o ms min  N ms min     An input is active low  1      H     0      L       14  Error Display  Display Resetting Method    Count standby status Press  P SET     at power on or The power supply needs to   instantaneous power be checked for an   interruption instantaneous power  interruption     voltage supply   digits or more  and press  P SET      Error40 Abnormal gage Press  P SET  and check  for correct gage    connection     digits or more   Error90 Press  P SET  and input  error tolerance limit again     Key protection Set P  No  35 to 0     Note      During tolerance output   NG is low      if an error occurs during parameters  preset values  or tolerance  limit settings  an error is displayed after the counter has returned to  the count status  However  the error is immediately output to the  external output device     PSET          15  Specifications    542 007  C 101D    axes  EEU V to  12 V  400 mA max    Power consumption 14 8 VA    Operating O to 40  C  20 to 80  RH with no condensation   temperature       Storage temperature     10 to 50  C  20 to 80  RH with no condensation     External dimensions  96 x 84 6 x 48 mm   W x D x H     16  Standard Accessories       Washer  plain washer  nominada 4    6   Cuber fest  596688   AG adapter  ADS08N   1  Warranty card    17  Optional Accessorie
2.    lt 6 gt      lt 8 gt   lt   gt      lt 3 gt  UNIT indicator  flashes when the HOLD signal is input    lt 4 gt  Sign    lt 5 gt  Gage input connector    lt 6 gt  I O connector    lt 7 gt  AC adapter input    lt 8 gt  Grounding terminal    lt 9 gt  Cord clamp    Mitutoyo    8 3 Setting parameters  Set the counter parameters so they are appropriate for the gage to be  connected  Perform required settings such as switching between the  tolerance and Digimatic output     Parameter list    No  Parameter Name Setting Initial  Setting    Parameter mode selection 0  Reference  To set parameters  select 1  1  Modification    ka  Settings other than 0 and 1 are  User parameter clear      Initializes the user  parameters     prohibited    ae  1   Count direction selection When the spindle is pushed in    0    count   1      count  2   Gage type setup 0  INC  LGS  1   1  ABS  LGD  IDC  SD  etc     2  Multiple units connected  4    14  Startup mode 0  At startup         display  1  0 000    5  mm inch unit system display  0  mm   4 selection 1  Inch 5 100 000 reads  2  Not initialized by user 2  Inch 1 10 000 reads  2    1  1  1  1    parameter clear  3  mm  when 1 100 000 inch gage   Inch   1 25 4 mm  connected     2  x10  1  Least significant digit blank  output switch 1  Digimatic output   5   digimatic input wait 1  200 ms wait  35   Key protect 0  Normal    Malfunction is prevented  1  Disable key input    1  x2  3  Arbitrary  3    2  400 ms wait     1  If this parameter is cleared
3.   97 i    Panel machining size   Thickness of panel that can be  mounted    1 mm to 3 2 mm       8 1 2 Attaching rubber feet  When setting the counter on the desk  adhere the rubber feet included  with the counter to the bottom of the unit case    CAUTION    Once the rubber feet have been adhered  the counter cannot be  mounted to the panel     8 2 Connecting connectors    Be sure to disconnect the AC adapter plug before  connecting connectors   CAUTION    1  Connect the linear gage to the INPUT connector    2  Connect the grounding wire to the grounding terminal    3  Connect the cable to the OUT connector  The user must supply  the cable    4  Connect the AC adapter     Use the cord clamp to connect the AC adapter     If an external DC power supply  option  is used   connect the power cable as shown below     Vagal       ss AGV     Watch the following when using the EC 101D   e Do not route the power cable and gage cable with other    How to install  the AC adapter                                           7  Appearance  lt i gt   lt 3 gt  20s CAUTION power lines through the same piping   Ag e Use a shielded cable with a length of 3 m or less for the  URDA   OUTPUT cable   O  o ne  o_o e Be sure to ground the counter        gg E88 e Clamp all cables to the counter body    lt 4 gt  EA   Le  Pe      lt 1 gt  Tolerance limit indicator  91 4 66    67 _    Approx  8  lt 2 gt  P  SET indicator                Code No  542 007  Model EC 101D  Serlal No  000001    be ak i           
4.   the preset value and tolerance limits are  cleared     2  When the inch type gage is connected  the minimum reading is the  resolution of the gage     3  For how to set the constant  refer to 10     4  The display speed can be changed   When the Multi Unit is connected  set P  No  12   2 and P  No  29  1   Do not set the SELECT switch of the Multi Unit to    EX        5  An error can occur when a special gage is connected   cases  set P  No  29 to 1 or 2     In such    1  Parameter setting procedure    Li Key Operation Corresponding Display Output    Turn the counter on  The counter enters the count  standby status     RRB BE    Displays the first parameter No   00   The flashing digit can be  modified      008538    Parareter    Press the  P SET  key  while holding down the   Fn  key to set the  parameter mode     Press  P SET  to set the  set value to 1      P SET        688538    Press  Fn  twice      BEEEES    The current setting parameter  11 will flash     Press  Fn  to advance the  parameter number        Kawasaki  Japan       Zz Key Operation Corresponding Display Output    5   Press  P SET  to set the    P SET     aver  ABBgEB    Press  Fn  to secure the  setting and move to the  next parameter number     required times   Press  P SET  while  holding down  Fn      The counter returns to the count  display mode to display a  counter value under the set  parameters        Note    Unless parameter No  00 is set to 1  no parameters can be  changed     9  Setting Parame
5.  large current power equipment    5  Warranty  If the Mitutoyo Digimatic Gage Counter  EC 101D  should prove  defective in workmanship or material  within one year from the date of  purchase  it will be repaired or replaced  at our option  free of charge  upon its prepaid return  For further information  contact your dealer or  local Mitutoyo sales office     6  Overview  The EC counter is a small counter conforming to the DIN size  96 x 48  that  allows for easy installation or incorporation  The EC counter features a  tolerance judgment or SDP output function  Gages with a Digimatic output  can be connected to   Main features    Key function   Presetting  zerosetting  tolerance limit setting  Tolerancing Pe   3 stage tolerance limits  Output Tolerancing output or Digimatic  switched by  function    parameter   Input Presetting hold  during tolerance mode   function                                                                                           A    User   s Manual  No  99MBCO89A1  SERIES No  542    8  Setup   8 1 Installation   8 1 1 Mounting counter on panel  After removing the fixing metals of the counter  insert the counter unit in  the panel from the front side and fix the counter from the rear side of the  panel using the fixing metals  Use the required number of washers  included with the EC 101D that are appropriate for the thickness of the  panel     Panel thickness  mm    1 0 to 1 3   1 4to 1 7   1 8to2 5   2 5to 3 2  Number of washers   0   1   2   3    
6.  set value to 2  0  ae omo o  tolerance limit  o Red   3   Press  Fn  and then the      m  When the tolerance indicator O ae  O set constant is displayed     J  lights red  the displayed value   z O   Q O O ra A   is the previously set value  aw       om   4   Set the value following  the same procedure as  for presetting   Press  P SET  while The display returns to the  holding down  Fn   counter value     Press  P SET  to perform presetting     Setting tolerance values other than lower limit  lt  upper limit    Press  P SET  five times  O     mi     OOS    j  10  Setting Arbitrary Constant  When the tolerance indicator while holding down the displayed   lights orange  the displayed  Fn  key  O Oc 0  Follow the procedures in 3 to 7    above to set the tolerance limit   Press  Fn  to input the upper    Fn       O Q Q  Press  Fn  to complete setting   U  and return to the count status  DSS A o  nd ade   Set value range   9 9999  Note  results in an error  In this case  press  P SET  to set the values  again       When the arbitrary constant is set  the decimal point flashes     11  Backup Memory Function  The following data is retained even if the power is turned off     Parameters  preset value   Retained  tolerance limits       Retained only during ABS mode    12  1 O Connector Terminal Function    12 1 Output circuit    Operation  The transistor is turned on when the input is low    Open collector     Output withstand voltage  24 V max  Surge absorbing diode    Output curre
7.  to the normal    E fi       O O e  Press  Fn  to enter the setup   Fn  ON     gt  OFF  2        9 4 ON OFF    Follow the procedure below to turn the counter display on or off   gage or I O cable is connected  disconnect the AC adapter      Description Key Operation   Corresponding Display  1   Count status m   3  O O e    2   Press  ON OFF  to turn    ON OFF   the display off     O O     BBE  O Q O  Press  ON OFF  again to    ON OFF   turn the display on  The m  display at this time is as  H 4 O 9 A    follows according to the O   ae  gage type    ABS mode  When the  value is OFF    INC mode  Display value  such as ID    mode  P SET    The preset indicator flashes mm  and the preset value previously     set is shown  OC     If the     ZERO     00000    Press  P SET  ten times     000000    Press  ZERO  twice    When  ZERO  is pressed  the  most significant digit will flash        displayed value    The most significant digit can  be set with a minus sign   MSD  0  gt  9  gt   0  gt   9  gt  0          Press  P SET  to change the  4    Press  ZERO  to move the  flashing digit        Press  P SET  to change the  displayed value                 aun O     Press  Fn  to complete the  presetting of values   Fn  Description Key Operation   After this  proceed to inputting    e Corresponding Display  ee range  z _ the lower tolerance limit  3 Cum    1   Press the  P SET  key The first parameter 00 is  value is the previously set a  value   a 2   Press  P SET  twice to  O KO  set the
8. Digimatic Gage Counter EC 101D    1  Safety Precautions  To ensure operator safety  use the instrument in conformance with the  directions and specifications given in this manual     2  Foreword  To obtain the highest performance and the longest service life from  your Counter  carefully read this User   s Manual thoroughly prior to  setup and operation  After reading this manual  keep it near the  Counter for quick reference  Be sure to follow the precautions below     3  Conformance to EC Directives  This unit conforms to the following EC directives   Standard  EN61326 1997 A1 1998  A2 2001  A3 2003  Immunity test requirement  Annex A  Emission limit  Class B    4  Precautions on Use       Neither remove the cover nor disassemble this unit    Doing so may expose personnel to electric shock or  i result in damage or fire to this unit due to a short circuit  WARNING caused by metal chippings or dust       Note the warning labels on the top surface of this unit       This unit is a precision instrument  Do not bump or apply  excessive force to any part of this unit when setting it up  or operating it      Use this unit in an environment where the temperature is  between 0 and 40  C  Temperature variations should be  minimized so that there is no condensation       Avoid operating this unit in the following places    e Where it will be exposed to cutting chips and oil  dirt   dust  or significant vibrations    e Where it will be exposed to direct sunlight    e Near high voltage
9. nt  20 mA max           i eee   Output saturation voltage  0 7 V max  oe m    TD62583 or     equivalent     Output d    e E    Note  Use a surge absorbing diode or a relay with a built in surge absorber  when using a relay to protect the output circuit     12 2 Input circuit    Operation  An input is valid when it is low   External device   Reference circuit     Use an open collector    output or relay output     Counter        Input current  Imax 1 mA  Input voltage  H   4 to 24 V  L 1V max     12 3 Pin assignment    Tolerance output mode    OUT Applicable plug    9    a MIL type connector  FAS 10 17  YAMAICHI   XG4M 1030 T  OMRON    lt 10 gt   lt 2 gt        1  During tolerance judgment mode    No  cable color  to GND  Es    Tolerance output  Brown red  3    The corresponding Yellow black  output terminal is low  Vellouied  When an error is  displayed    HOLD   HOLD input Green black  P SET  Preset input  error Green red  cancel   No connection for  other than above      The pin functions are different during the Digimatic output mode   After setting the output mode  connect the cable      One end of the I O cable is not bunched and requires processing by  users  Connect the F G line to the grounding terminal of the  counter  Connect the F G terminal  with green solderless terminal   of the cable to the earth terminal of the counter     Bis  C O  Fa    I O cable  option        ro   com  ae   W    Mitutoyo    13  Timing Chart  1  Tolerance output  Upper tolerance limit      
10. s  Separate Order     936937 Connecting cable for Digimatic mini processor  1 m     965014 Connecting cable for Digimatic mini processor  2 m   214938 PJ 2  DC plug              C162 155  I O cable  2 m     
11. ters  9 1 Turning on the AC adapter power supply    a Procedure    1   Turn the counter on   The counter enters the  count standby status   2   Press  P SET  to return to  the count display     Key Operation   Corresponding Display    PRA     P SET     8886    9 2 Zero setting  presetting  and error resetting    Use the  ZERO  or  P SET  key to set the origin   By presetting the  P SET  key  the preset value can be changed  refer  to 9 4  and the origin  0 at factory setting  to the arbitrary value     Key Operation     Ty  2 1600    2   Press  P SET  or  ZERO        When counter value is 1 000     P SET     6666     If an error occurs  press the preset key to reset the error     Note       The preset count of the effective zero for the gage type  ABS  is 1  million times       After the error has been released  all of the decimal points flash for  approximately 8 seconds        2  Tolerance judgment result  When tolerance limits have been set  the tolerance is judged in three steps  as shown in the table below     Tolerance   I O Output  Indicator    Measurement  lt  Lower limit    9 3 Setting preset value and tolerance limits    Always set the preset value and tolerance limits in this order   The  flashing portions are indicated in gray in the following diagram      1  Setting preset value and tolerance limits      Key Operation and Corresponding  Display Output    Lower limit  lt  Measurement  lt  Upper limit  Upper limit  lt  Measurement Red HNG o O        Set the counter
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
Amendment-3-WBMSC-Medical Equipment  BoConcept Model 3800 Assembly Instruction  Istruzioni per l`uso  Acer Iconia W3-810-27602G03nsw 32GB Silver  PROLIFT - RIO beauté  Sansui SLED1953W Flat Panel Television User Manual  Pro val.indd  Sony MZ-E810SP User's Manual  Battery  Telstra Outdoor Gateway with Indoor Access Point    Copyright © All rights reserved. 