Home
VBM 1063 - Vollmer America
Contents
1. loosen the clamp screw S get a good hold on the gauge head and pull the gauge off the rotation bearing To remove the transducers At first remove the round cover from the top of the housing two Allen bolts visible from above Then loosen the transducer clamp screws accessible through the two holes B1 and B2 and remove the transducers from the measurement frame To remove the guide rollers The VBM 1063 is available with spring sus pended or with pneumatically operated guide rollers mod pn see next page Spring suspended rollers see photo above Start with the removal of the upper guide roller holdings together with the rollers two bolts A Then it is possible to replace all rollers without having to remove the holdings of the lower rollers Do not install the upper rollers before the transducers are in place If possible do not loosen the screws in the holdings of the lower guide roll ers This would require a complicate alignment procedure by Vollmer The rollers itself can easily be replaced by loosening the screws C which clamp the roller axle in the holding OBS EMS Operating and Service Manual VBM 1063 19 measuring controlling recording automation documentation pneumatically operated rollers pn The upper transducer must be re moved to give way for the removal of the upper rollers Loosen the screws N on both sides of the
2. Compressed air supply Working pressure for pneumatic guide roll ers optional is 3 5 bar de pending on the strip material controlled by a magnetic valve that opens if the light barrier is detecting that the gauge is in measurement position lamp P in position is on Transducer lifting device When the gauge is traversing the thick ness indicator needle must be at the minus limit stop Symmetry check Switch into the Service I mode set nominal size to 0 move both transducer tips up and down indication has to be 0 um 0 5 um In case of tight tolerances check daily otherwise weekly Gauges with AS do this procedure automati cally Both ways are described ina separate manual for the VMF amplifier Side view of the pneumatic cabinet Accuracy check with slip gauge Set the gauge to the nominal size of the slip gauge and insert the adjustment plate between the transducer tips The indication should be zero In case of tight tolerances check daily otherwise weekly OBS EMS Operating and Service Manual VBM 1063 13 measuring controlling recording automation documentation Transducer position to the strip The transducers must stand perpendicu lar to the strip Lift or remove the upper guide rollers and put the test plate onto the lower guide rollers Tip it to both sides as well as to the front and to the bac
3. ing screw F Note The upper diamond must always carry some weight to avoid wrong measurement This becomes visible in form of sudden peaks on the record er Yee NS yi N 1063 E2 PM5 Operating and Service Manual VBM 1063 29 measuring controlling recording automation documentation Installation When the gauge is installed into an inspection line installation height and levelling of the gauge are derived from the inspection table If the gauge was removed from its position take care to reinstall the slidebase angular to the passline In rolling mills the gauge should be installed as described in the following sketch Ww G gt S lt a i p 4 a H U If possible the gauge should be positioned between the roll gap mill W and the deflector roll U Base and the bracket K are so high that they lie under the strip by the passline height H see data drawing in the documentation Here the stroke of the vertical guiding is able to follow the expected range of strip movement Additional conditions are base parallel to roll axes in the mill slidebase rectangular to the strip gauge must be able to traverse towards the roll middle 30 1063 E2 PM5 VBM 1063 Operating and Service Manual FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke
4. For your own safety please make sure to get familiar with the control program sequences before you start to work on the gauge Intended use of this machine This gauge must be used exclusively for the measurement of cold strip It must be firmly installed in its intended position and electrically electroni cally hydraulically and pneumatically connected as intended by the Voll mer company Any alteration might cause severe damage We care about your health Please follow the safety precautions Especially if you have many years of professional experience you willbea Good exam ple for young er colleagues 1063 E2 PM5 Operating and Service Manual VBM 1063 measuring controlling recording automation documentation Operation mode selector switch Service I 0 If the gauge has an automatic traverse unit the electronic cabinet contains a selector switch Service I 0 Service 0 is the position for the normal operation mode in which the gauge is traversed back and forward automatically If e g ifthe strip tension breaks down or if the strip moves laterally the gauge head is traversed off the strip into its rear limit position with double speed Danger Crushing Hazard Nobody is allowed in the danger zone as long as the system in the Service 0 mode Service I is the position for service operation The gauge head can only be traversed by inching service by manual controls in the operator
5. measurement head and pull off the bolts P The two rollers with beam Q can now be pulled off towards the front The ka unit needs only to be removed completely if one wants to open the gauge housing After the upper guide rollers were removed loosen the screw X on each side of the gauge and the grub screws in the two holders Y Then pull out the bolts V and pull off the upper guide roller holding towards the front together with the pneumatic cylinders Now loosen the two grub screws M on axis W remove the four retaining rings push the axis out of the hous ing To remove the housing from the ka frame The housing is fastened to the frame ka by four Allen bolts 5 mm hexagon socket wrench They are accessible from below near rotary bearing D Loosen the four screws and take the gauge head off the ka frame 20 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralse 60 49 2334 507 0 Fax 49 2334 53015 To disassemble the housing O remove the black protection fitting B put the housing on its left side so that the alignment hole J is up Remove adjustme
6. resistor in the transducer cable connector as well as the VMF phase and sensitivity adjustment On gauging systems with transduc ers of the 90 series and VMF 3 2000 amplifiers parts of these procedures are performed automatically see separate manual 28 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 To adjust the measurement frame If the gauge is measuring with two transducers in sum then upper screw A holds the C frame in the 90 position The front end of the frame can only move up as overload protection The spring loaded screw F is pushing up the rear end of the measurement frame to pveent it from swinging Here is no need to change the factory adjustment even when rolling very thin strip EAN Di VBM 1063 The spring loaded screw F is supporting the measurement frame Ifthe gauge has one transducer and one micrometer single measurement the strip is lifting the C frame when the gauge is on the strip This lifts the bottom transducer against the strip surface The stronger the C frame has to be lifted the safer both sides will keep surface contact But the pressure must not be too strong in order to avoid traces on the strip When rolling very soft or thin material it is possible to give a pressure relief by loosen
7. the VMF 3 2000 Measurement start and end For measurement the gauge is forwarded to the on strip position If it has a DAV the transducer tips are then lifted automatically until the gauge is in measurement position Measurement amplifier and classifier now indicate the difference between nominal and actual size and whether the measurement value is in or below tolerance or if it is exceeding the upper limit Important note for manually traversed gauges Please do always move the gauge off the strip before the strip tension is switched off The strip end must never pass through the gauge as it will cause serious damage 12 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 Continuous checking In between the service intervals it is recommended to check the gauge reg ularly Temperature After the gauge was traversed into the rear limit position the temperature must nwa 040 o not change That means the temperature deviation indicator TD should remain constantly close to zero If the tempera ture is not constant adjust the heater by setting a new gauge temperature with the two knobs S Ideally the Lamp H Heater at the pneumatic cabinet is in dicating that the on and off periods are of about the same Temperature control device in the electronic duration cabinet
8. the two e O digit switches DK ofthe electronic clas A e nd sifier Coloured control lamps indicate whether the measurement value is in over or below tolerance Such classi fiers are optional equipment their op eration is described in a separate manual The optional nominal size selector FS4 shows the selected nominal size in microns or steps of 0 0001 depend ing on the FS4 type The amplifier VMF 3 2000 includes all components described above It puts out the measurement data with statis tic evaluation ready for quality control documentation according to ISO 9000 Its internal automatic adjustment pro vides the best possible measurement accuracy at any time The VMF 3 2000 amplifier is capable of processing transducer signals of over all 4mm measurement stroke instead of 2 mm like the VMF 3 11 and 3 22 ERGEBNIS i 2 types Transducers of the 90 series and the VMF 3 90 amplifier can be used n z to upgrade nearly all Vollmer gauges 6 VBM 1063 Operating and Service Manual peg Ee EM FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 Nominal size setting If the required material thickness e g 500 um is entered as nominal size and if the measurement is 501 um the amplifier will indicate 1 um So it is possible to stay within the highest sensitivity range of the in
9. 1063 E2 PM5 vallis Automatic Thickness Gauge For Fast Running Cold Strip VBM 1063 Operating and Service Manual measuring controlling recording automation documentation Table of Content re Safety Precautions Intended use of this machine Operation mode selector switch Service I O ccceecccesceseesseeseeeeteeenseeteeeaes 4 Design and funCti On sar ehehe a e a E Gaveeeth usd 4 SYE A E A Han a ETR 6 Nominal size Setting wiccccscccdesseoivtescacostbssndescesccct catiuevevdsSeueustcvahsuaecetsonsabetes 7 EYP OS see shea Be diend Covailessea Sats cetuns coven dudta cats cebest devsis dea Sevag E cake reverie 8 Operations oeenn tee he aan andi en eaten 10 Measurement etopucntencied edie a a i ee abi dase te ILIKE CHECK 2s ies cast onice ces sacdescans cashes daciensuaeansduseseasasatiatons TA Indication check 2 2 s eisarseteacet atiapan iene Avera eee Nominal size and tolerance limits Measurement start and end eee Continuous checking 1iv sin Lenin r EE E T RON 13 Safety Precatlons vies sccecberek Boog lece sods ohcseus t 14 Troubleshooter rasa aeon a a die inGuia alain tes If the gauge measures wrong If the gauge marks the strip eseessessssssesesssessrsssssessseseesrsseeseeseeseeseeseeseese 17 Maintenances eeei erea EE E E E Guide rollers Measurement frame To remove the gauge To remove the transducers ccceseeseeseeseeeeeeeeesees
10. 3 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 If the gauge marks the strip Diamond with small cracks If hit too hard the diamonds in the transducer measurement tips might get tiny ring shaped cracks which are hardly visible Sometimes such cracks mark the strip gt replace the measurement tip Diamond broken out In case of strip breaking a diamonds might break out of a transducer measurement tip replace the measurement tip Roller blocked gt Replace the roller Ifthe roller surface is not damaged replace only the bearings ibe E at MS Operating and Service Manual VBM 1063 17 measuring controlling recording automation documentation Maintenance The thickness gauge does not need much maintenance Only the measure ment tips with the diamonds and the guide rollers are subject to wear The gauge should be cleaned regularly in order to avoid dirt deposits which might block movable parts At least the following points must be checked regularly even if measure ment results and symmetry are correct Guide rollers Clearance The rollers have to move freely They should have only little axial clearance Blocking rolls mark the strip Replace defective rollers Deposits on the surface Some strip materials tend to leave deposits on the rollers They cannot run smooth and might mark the strip replace rollers rework if possible Roller support
11. 60 49 2334 507 0 Fax 49 2334 53015 Measurement head adjustment Passline height The upper limit stop of the vertical guide should be set to a position where the lower guide rollers touch the strip edge with the upper third of their slope Loosen lock nut Y below nut Z and use nut Z to adjust the gauge head to an appropriate height Finally tighten lock nut Y The large aluminium knob X is used to set the tension of the suspension springs The suspension should push the gauge head against the upper limit stop of the vertical guide but not too hard so that the strip is not lifted by the gauge head In that case reduce the suspension load It is set correctly when the gauge head is slightly lowered by the strip when it is forwarded to the measurement position When measuring very thin strip the bottom lim it stop might be lowered a little so that the lower guide rollers put less load to the strip However the height must not be reduced too far so that the lower guide rollers are not permanently driven by the passing strip Gauge head passline adjustment Axial alignment with clamp screw S height adjust ment by means of nut Z and suspension adjustment by knob X See the text above and below for details Levelling If the strip does not run horizontally the gauge head can be turned Loosen clamp screw S at the rear of the gauge Lift the gauge at the fr
12. Trouble shooting Indication check If the previous test shows a constant zero check the gauge measurement by means of an adjustment plate with integrated slip gauge optional addition This test should be made regularly especially when rolling with tight toler ances The gauge must be in its rear limit position and in the Service I position At first set the nominal size to the thickness of the slip gauge and turn off the working pressure of the pneumatic guide rollers Then insert the slip gauge plate between the guide rollers as shown in the sketch When the transducer tips measure the integrated slip gauge then the indication should be very close to zero 0 5 um If not check the entire gauge adjustment To check the gauge with an adjustment plate The thick part in the center of the plate is pointing downwards Please follow the safety precautions and set the gauge into the Service I mode before somebody is allowed to go into the danger zone 1063 E2 PM5 Operating and Service Manual VBM 1063 11 measuring controlling recording automation documentation Nominal size and tolerance limits After the zero check nominal strip thickness is set mechanically by fine adjustment micrometer and or electronically by the FS4 thumb wheel switch The tolerance limits can be entered into the electronic classifier 2S or 4S optional item see separate instructions or by then keys of
13. ce the bearings remove the outer shell of the left bearing and replace it by a new one whichs screws are not tightened put new balls in the new left inner bearing shell 10 balls per section take that inner shell with the balls in one hand and the left half of the housing with the outer shell of the bearing in the other hand Put the housing with the outer shell on top of the inner shell with the bearings press the parts together and turn them upside down put in the C frame and then the washers put the cleaned old inner shell of the right side bearing onto the C frame and insert the cleaned old balls put on the right half of the housing and press everything together insert the two screws S and tighten them while moving the C frame in its bearings The C frame must remain easy movable but no lateral clear ance is allowed Adjust this by removing or adding one washer on each pin pushin the alignment pin tighten all four screws SK of the left side shell now change the right side bearing in the same way so that it will be precisely positioned by the new bearing on the left side To assemble the housing Before finally closing the housing lubricate the ball bearings well with res in free oil After the housing was assembled check the C frame again for easy movement If there is any resistance in the bearing remove one dis tance washer from each pin The C frame must be easy movable all the way up and down ev
14. defective On strip the pneumatic guide rollers are pressed down working pres sure 3 5 bar Check regularly if the upper guide rollers move up to their mechanical limit stop when the compressed air is switched off Standard guide rollers are pushed down by pressure springs They should be moveable so that they can be pushed up in their guiding Check the lower guide rollers for parallel adjustment see under Con tinuous checking Transducer position to strip clean the ball guides if the rollers get stuck Measurement frame Easy movable The C frame might get stuck because of major dirt deposits in the gauge mechanics or if after long time of operation the C frame bearing is worn This might cause measurement errors The measurement frame must rest against its bottom limit stop In that position the alignment pin must slide easily into the adjustment hole Clean the gauge send it to Vollmer for repair if the bearing is defective 18 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 To remove the gauge First undo all plugs at the connector board behind the gauge and remove the plugs from the board so that the cables which lead to the gauge head are free Check the measurement head for temperature it might be hot Then
15. dicator no matter of the material thickness In this range the full deflection of the indicator covers a range of 10 microns Nominal size can be set in several ways mechanically single measurement with micrometer fine adjustment The fine adjustment is set to the selected nominal size on its micrometer thread The size is indicated by a digital turns counter mechanically sum measurement adjustable transducer The adjustable transducer is set to the selected nominal size on its mi crometer thread Depending on the model the nominal size is indicated by a digital turns counter mod Di or a scale mod Scale or via an electronic pulse encoder on a separate digital indicator mod ME electronically sum measurement with two transducers and FS 3 4 there is no mechanical transducer adjustment but the measurement value is electronically compensated for the nominal value by the setting of a thumb wheel switch so that the selected nominal size is indicated as zero The electronic adjustment is limited to 1 5 or 3 mm depending on the trans ducer type It can be combined with an adjustable transducer mod Di Scale or ME i e the upper transducer is mechanically adjusted to one nominal size and from that position it can be adjusted electronically to different nominal sizes Depending on the application there are additional control indicator or data processing devices which can be connected to the measurement electron
16. e gauge is in its rear limit position The gauge is set to nominal size zero Then the amplifier adjusts itself to zero This procedure is started either by pressing a key or by time automatic available only in combination with VMF 3 22 or VMF 3 2000 DAV The diamond measurement tips of the two transducers are pneumatically pulled apart when the gauge is traversed in order not to damage them at the strip edge For measurement of wavy strip or vibrating strip the measure ment pressure can be pneumatically increased to prevent the measurement tips from losing contact to the surface 8 VBM 1063 Operating and Service Manual peg Ee EM FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 2S dig Digital electronic classifier decade switches to set upper and lower toler ance limit In tolerance values are indicated by a green control lamp be low tolerance is shown in red and exceeding the upper limit is indicated by a yellow lamp AS Automatic symmetry adjustment the transducer tips can be moved up down pneumatically instead of manual manipulation Hwst 500 hydraulic traverse unit consisting ofa control unit and a slidebase stroke of the hydraulic cylinder is 500 mm ibe E at MS Operating and Service Manual VBM 1063 9 measuring controlling recording automation documentation Operation Depending on the application the gauge ope
17. e zero point changes The indication is incorrect even if the symmetry is correct Fasten the grub screws in the guide ram see transducer manual Long term drift of the zero point An integrated heater heats the gauge so that the temperature does not change whether the gauge is measuring or not The temperature control should be adjusted so that the gauge always keeps the same temperature when it is moved off the strip or when the measurement starts after a long stop The temperature should not drift for more than 2 C degrees 1063 E2 PM5 Operating and Service Manual VBM 1063 15 measuring controlling recording automation documentation Short term drift of zero point Can be noticed if the rolling has been finished and the gauge in its rear position is directly moved set to nominal size zero without pushing AO If then the indication drifts away to or the cooling of the diamonds does not work correctly Check if the small air pipes are not bent Com ing from the ingoing side of the gauge the jet has to meet exactly the tip of the transducer Re adjust the cooling at the pressure valve in the pneumatic cabinet connect the air supply correctly or adjust air pressure if the display drifts away to minus increase cooling if the display drifts away to plus reduce it Indication too low Ifthe transducers in the C frame are clamped not tight enough they might be shifted in their bore Gauge zer
18. eceececeseesesseeseceeseeeeaeens 19 To remove the guide rollers cccccecccessesseceseesseeeeeseceseeseeeeeeseeeseeseeeaes 19 To remove the housing from the ka frame eceecceeseeteeteeeeeeeeneenes 20 To disassemble the housing Spare Parts ccccesecsseeseeseeees To replace the bearings ccceseeeeees To assemble the housing Measurement frame adjustment 0 0 0 0 ccccceecccesseeseceteeeeeeeeesesseeeeseeseeeees 24 To assemble the guide rollers eceeccecsceeseeesecesceeeeeeeeseeeeceseeeseeeseenee 25 To check the transducer alignment cceecceccsseeseeeeceeeeseeeeneeeeeeseeneeaee 25 Pransducer Check eieren css uh E e Torei Transducer installation 06 To check the transducer position Symmetry check ceeeeeeeseeteeees To adjust the measurement frame 0 cceeceseesccesseeteceseeseceseeeseeeseeeeaes 29 Wristallat Ont e5 scceageseess ere a alate ose fH oh beaten das A beta ec ees Measurement head adjustment Passline height 0 0 0 0 cece Levelling se escent cies Strip breaking sv sescsecectedesecsdycansias cuts cavenss deve conssuadecedicates dedecbasuenscdveceteeiedees 32 2 VBM 1063 Operating and Service Manual peg Ee EM FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 Safety Precautions please read carefully This manual has to be handed to the machine operator and one copy mus
19. en if that means to have a little lateral clearance 1063 E2 PM5 Operating and Service Manual VBM 1063 23 measuring controlling recording automation documentation Measurement frame adjustment First insert the brass screw F with its spring and ram and screw it to its original position so that the C frame is spring pushed against the limit stop U There should be a perceptible spring load when the front end of the C frame is lifted from the limit stop Ib Misa A VBM 1063 The measurement frame is held by two ball bearings in the gauge hous ing Then insert the alignment pin J into the gauge housing This aligns the C frame in the 90 position so that the transducer bores are exactly perpen dicular to the lower guide rollers axes VBM 1063 with alignment pin J That pin is used to align the C frame to the 90 position when installing transducers or adjusting the limit stop screws 24 VBM 1063 Operating and Service Manual peg Ee EM FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 Now adjust the limit stop screws A ingauges withsum measurement two transducers with movable tips turn the upper screw A clockwise and lock it in that position where it is just touching the C frame When the adjustment pin is now pulled o
20. ent the rams of the transducers sometimes get too sticky so that they do not shut completely If the gauge is then set to zero the indication of a following measurement is too low After clean ing any transducer ram should slide easy in its bushing or bearing for a quite long period of time gt increase cleaning frequency Transducers clamped too hard If the clamp screws in the C frame are tightened too hard they possibly distort the transducer housing which increases the friction in the ram guiding loosen the clamp screw and re tighten with moderate force Oil in the flexible cable protection hose The oil increases the friction of the ram guide bushing or ball bearing In that case the transducers cannot continuously keep contact to a vibrat ing strip The measurement then indicates too thick Much oil in the protection hose does additionally choke the diamond lifting Drain the oil from through the brass drain screw 10 mm spanner at the transduc ers cable entry Remove the Allen bolt from the white DAV plastic con nector peace and blow in compressed air see extra DAV instruction manual Clean the transducer and possibly improve compressed air quality Gauge zero not constant If the screws which connect the measurement tip with the guide ram are not tight the measurement ram might move against the guide ram If for example DAV was activated or material was placed between the transducers and then removed th
21. from Vollmer It must slide easily through the two clamps If not have the C frame aligned at Vollmer or replace it ibe E at MS Operating and Service Manual VBM 1063 25 measuring controlling recording automation documentation Transducer check This is just a basic check of the transducer function Please read the sepa rate transducer service manual for service and repair Ram easy movable The transducer rams must be easy to be pushed in and spring back imme diately Measurement tips worn or damaged If the measurement result of the slip gauge plate is not 0 but the other checks are all right remove the transducers and check the measurement tips Diamonds worn The diamonds should be crowned to achieve accurate measurement re sults Worn diamonds with flat spots may cause measurement errors gt Replace and possibly get the old diamonds reworked Broken diamonds Cause incorrect measurement results and mark the strip gt Replace Measurement tips with broken out diamonds after strip breaking or when the strip end has passed through the gauge gt Replace Micrometer thread damaged Worn micrometer threads cause measurement errors Check Set the trans ducer to zero select a nominal size and insert the correspondent slip gauge Try with several slip gauges The indication has to be very close to zero If not send the transducer to Vollmer for repair without trying to repair the
22. ics 1063 E2 PM5 Operating and Service Manual VBM 1063 7 measuring controlling recording automation documentation Types According to individual requirements of our customers Vollmer gauges are produced in many different types The gauge card in the documentation shows the type of your gauge The following list is a general overview about the available items e g VBM 1063 E Su FS4 pn ka T K A0 DA V 2S dig AS Hwst500 Meaning of the abbreviations VBM1063 E Electronic strip thickness gauge for high quality strip on fast cold rolling mills measurement depth up to 100 mm from the strip edge Su Measurement by 2 transducers in sum accurate measurement values even in case of strip vibration FS3 FS4 Remote selection of nominal size by a thumb wheel with 3 or 4 decades pn The upper guide rollers are pneumatically pushed down onto the strip i e the gap between upper and lower guide rollers is closed when the gauge is in On Strip position measuring position ka With this cardan suspension the gauge measures precisely even when the strip lies in a hollow shape T Heating elements in the gauge head for keeping a constant temperature against long term drift because of heat coming from the strip into the gauge K Air cooling of the transducer s measurement tips against short term drift if the measurement tips are heated by the strip AO Electronic adjustment system which works when th
23. k see sketch 1 through 4 The display may only deflect to the side If not check the whole gauge This check is recom mended after a strip breaking or other hard treatment For your convenience the Vollmer company offers a special adjustment plate with an integrated slip gauge which is individually selected to match the thickness of that strip which is usually rolled on your mill see pic ture under Measurement Indication Check Guide rollers Check for easy rotation Passline Check the correct height of the gauge to the strip Safety Precations Nobody must work on the gauge unless it has been switched into the Service I mode This mode makes sure that the gauge will not be automatically traversed and the pneumatic guide rollers will not close unexpectedly Caution Crushing hazard Never traverse the gauge as long as somebody is in the danger zone 14 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 Trouble shooting If the gauge measures wrong Wrong point remeasured Cross profile strip thickness varies in many cases If the gauge is checked strip thickness must be measured at the same distance from the edge as the transducers have measured check the strip thickness at correct edge distance Transducers dirty In a very dirty environm
24. l in housing and measurement frame becomes useless Clean C frame shells and balls with a non aggressive solvent and dry them completely with compressed air If there are any traces of wear in the shells replace both bearings and balls see To replace the bearings Ifthere were wrong measurement result e g after a strip breaking the alignment of the transducer clamps in the C frame must be checked with an inspection bolt available at Vollmer It has easily to slide through both clamps If not get the C frame aligned at Vollmer Spare Parts Each single item is named by its drawing number and the position number on that drawing For example A special guide roller of the VBM 1063 is item 101 6 a on drawing W68 005 13 Ba Note Please order spare parts exclusively based on the technical drawings in the docu mentation not on this manual 22 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 To replace the bearings The ball bearings should be replaced if there is any sign of wear at the shells In that case the C frame cannot move easy enough to follow all strip move ments Do not loosen the four hollow screws SK for 3 mm hexagonal sock et wrench on both sides at the same time This would make alignment drill in housing and C frame useless Here is a step by step instruction how to repla
25. nt screw F with spring and ram remove the two limit stop screws A remove the two bolts S Important Note Do not loosen any other than the items indicated here If you didn t have a special service training it is most likely that you will cause a considerable loss of measure ment accuracy take the right half off the left one possibly use a plastic hammer The outer shell of the bearing is fastened at the housing the inner side lies on the C frame Take out the balls and take the bearing off the C frame Do not swap the bearing shells OBS EMS Operating and Service Manual VBM 1063 21 measuring controlling recording automation documentation Take note of the number of washers spacers between C frame and bearing equal number of washers on each pin Take off the washers and put them aside Now remove the C frame and the inner shell of the second bearing There are no washers at this side Important note Do not loosen the four hollow screws SK for 3mm hex agonal socket wrench If those screws need to be re moved in order to replace the bearings only one side may be removed at a time Then the housing should be reassembled so that the remaining old bearing is posi tioning the new one The second bearing on the other side of the C frame must not be removed before the new one is precisely positioned and secured If both bearings are loose at the same time the alignment dril
26. o is then shifted too Indication wrong If the fine thread of the fine adjustment is defective the nominal size setting is disturbed Indication wrong Check the transducer symmetry by moving up and down both transducer tips If the indication does not stay 0 readjust the transducer symmetry Additional check for gauges with decade switch type FS3 FS4 After symmetry adjustment or after a new transducer was installed the ad justment of the measurement amplifier to the nominal size selector has to be checked by a slip gauge Set the gauge to 0 and insert 500 or 800 um slip gauge Then set the decade switch to 500 resp 800 and check if the gauge measures zero If not adjust the VMF to the nominal size selector switch by the X9 sensitivity potentiometer Indication too high Put an adjustment plate onto the lower guide rollers and set the gauge to zero Tip the plate it to both sides as well as forward and backward The indication should deflect only towards If not check the complete gauge measurement tips for wear C frame for 90 position and C frame distortion Indication too high After strip breaking or when the strip end passed through the gauge the C frame is possibly bent The indication is too high Check as before and check the alignment of transducer clamping bores with a 20 mm inspec tion pin 16 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 5809
27. ont adjust it to the strip passline angle and clamp it again OBS EMS Operating and Service Manual VBM 1063 31 measuring controlling recording automation documentation Strip breaking The gauge is mounted onto the slidebase with a shear block This is to pre vent the gauge and its suspension from destruction in case of strip breaking Shear block B is made from cast iron and easy to replace In case of over load it shears off so that the gauge and its suspension can move with the broken strip Please check the gauge zero after each strip breaking If it has not changed measurement can continue immediately If the gauge zero has shifted for a minor amount set the measurement amplifier to zero and check the symme try Check a the gauge with a slip gauge which is integrated into the adjust ment plate addition available from Vollmer If these points are all right measurement can go on If the symmetry is disturbed or if the measurement does not indicate the exact thickness of the sample check the whole gauge Take special care of the diamonds the easy movement of the transducer rams and the alignment of the transducer holes in the C frame Safety precautions The gauge head might become hot Check temperature before touching it 32 VBM 1063 Operating and Service Manual 1063 E2 PM5
28. rates manually or automatical ly controlled During manual operation the most important thing is to move the gauge off the strip before the strip end runs through it If in automatic mode the gauge is switched to on strip it moves auto matically into the measurement position Ifit is ready to measure the meas urement electronic puts out a start signal Mostly the measurement position is detected by a light barrier aside the measurement head As soon as the light beam is interrupted when the gauge head crosses the strip edge a timer starts which stops the movement after a preselected time set during commissioning Instead of the timer it is also possible to use a pulse encoder for the controlling of the measurement depth In that case the measurement depth can be set by a decade switch and the selected measurement depth is digitally indicated Off strip makes the gauge moving back to its rear position immediately independent of the actual position Before the strip end passes through and would damage the gauge an exter nal signal is given and the gauge automatically moves off the strip Various electronic interlocks are possible to avoid damage For example a strip ten sion breakdown may be the trigger for retracting the gauge Or the gauge moves only on strip and remains there if a certain rolling speed is exceed ed Each gauge is provided with a safety switch If the strip reaches too far into the measurement mou
29. s which do not leave any marks on the strip At its rear end each transducer has got a differential transformer The mov able core of this transformer is connected to the measurement tip which is sliding on the strip surface In this way any movement of the measurement tip is measured inductively 4 VBM 1063 Operating and Service Manual peg Ee EM FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 VBM 1063 The two thickness measurement transducers T are measuring in sum The measurement frame D is installed in two C shaped ball bearings All changes within both transducers are passed toa VMF measurement amplifier where they are added sum measurement The amplifier indicates a meas urement result as deviation from zero i e the difference to the preset nom inal size Depending on the type of the gauge there are several ways for electronic or mechanical nominal size setting so that the measurement amplifier indi cates 0 when the measured strip thickness matches the nominal thickness The C shaped measurement frame in the gauge has an extremely low tem perature extension It is held in two C shaped ball bearings The gauge head is held in the passline by a spring suspended vertical guide Guide rollers hold it always parallel to the strip surface Amplifier measurement data can be u
30. s desk The automatic traverse controlling is switched off so that the gauge will not move automatically Caution crushing hazard for hands and fingers Do not put hands or fingers into the vertical guide or the slidebase while the gauge head is moving Design and function The VBM 1063 is designed to measure strip thickness on high quality strip in fast running cold rolling mills The gauge measures the passing material continuously in its measurement mouth which has a depth of 100 mm The strip passes the C shaped thickness measurement frame with two thickness feelers which are measuring the running strip simultaneously from the top and from the bottom This can be done by single measurement or by sum measurement Single measurementmeans to measure strip thickness between an electronic LVDT transducer and a micrometer fine adjustment feeler It is designed for slow running strip Sum measurement is used to measure fast running strip with high quality surface Two electronic transducers measure the strip from either side As only a small amount of mass has to be moved instead of the entire C frame the two transducer tips are able to follow the surface even in case of vibrating strip Both measurement methods provide results of high accuracy but they re quire different ways of gauge adjustment Due to strip thickness changes the transducer tips are pushed apart or come closer The transducer tips are crowned and polished diamond
31. sed as signal for controlling and for quality monitoring documentation according to ISO 9000 It is available on two analog voltage outputs Some VMF amplifiers do additionally provide digital data outputs Side view on a VBM 1063 The Gauge head M is suspended by vertical guide V The vertical guide is traversed in the slidebase S by the hydraulic cylinder H between the rear limit position shown here and the measurement position on strip B OBS EMS Operating and Service Manual VBM 1063 5 measuring controlling recording automation documentation System The VBM 1063 gauge is always installed with a VMF measurement ampli fier This measurement amplifier indicates the difference between meas ured strip thickness and selected nominal size A separate instruction of the measurement amplifier is part of the documentation Measurement amplifier VMF 311 with i _ 2 electronic classifier 2S top and nominal gt DA DK size selector FS4 bottom The measurement amplifier continuously indicates the difference between nominal and actual strip thickness The opera torcan select the resolution of the ana logue indicator by the measurement range selector MB Full deflection can indicate from 1000 microns 030 down to 10 microns 0003 The zero po tentiometer NP allows to eliminate small we deviations of the gauge zero vM wean Tolerance limits can be set by
32. t be permanently available to operator and service personnel Nobody is allowed to work on or with the gauge before he has read and understood this manual Feel free to call the Vollmer company in case of any questions phone 49 2334 507 0 Warning Crushing Hazard In some applications this gauge has a hydrau lic traverse unit It has to be switched to the mode Service I before any body enters the danger zone When operating in the standard mode Service 0 the gauge might rush back or foreward unexpected and uncontrollable Hands or fingers which are put into the vertical guide behind the gauge or into the slidebase below the gauge might get caught and heavily injured if the gauge head moves up down or is traversed A pneumatic vertical guide and pneumatic operated guide rollers might cause injuries on hands and fingers In case of a pressure drop the vertical guide with the gauge head might leap up Under certain conditions the guide roll ers might close the gap unexpectedly Therefore the pneumatic system must be de pressurized before anybody starts to work on this gauge The aluminium gauge head might get hot Therefore check the temperature before trying to handle the gauge head If the gauge head is operated automatically or semiautomatically the doc umentation contains a description of the control program for this applica tion Nobody is allowed to work on the gauge unless he knows the control program sequences
33. th the gauge is retracted While the gauge moves forward or backwards the DAV Diamond Lifting Device operates automatically The transducers are lifted in order to avoid the diamonds scratching over the strip edge or click together when the gauge moves back The process is specified in the records of PLC if the gauge has an automatic traversing device In the Service I mode the gauge head can be hydraulically moved back and forward by inching operation In this mode the compressed air supply is switched off i e the pneumatic guide rollers cannot be closed and the DAV is not operational When pressing the AO button for an automatically traversed gauge the gauge is treversed to its rear limit position and is automatically set to zero After the amplifier has adjusted itself to zero the gauge is traversed On Strip again 10 VBM 1063 Operating and Service Manual 1063 E2 PM5 FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstrae 60 49 2334 507 0 Fax 49 2334 53015 Measurement Zero check Zero checking should be performed regularly Set the gauge to nominal size zero and check the VMF indication It should be zero Minor deviations can be eliminated by the VMF 3 22 zero potentiometer or by the Master key of the VMF 3 2000 Then operate the DAV or puta thin piece of material between the transduc er tips and take it out again The indication must return to zero If not check the gauge see section
34. thread by yourself Transducer installation After cleaning or diamond changing the transducers can easily be reinstalled into the C frame connect the bottom transducer B to cable socket X2 and put a test plate onto the lower guide rollers switch on the VMF measurement amplifier select the 1000 um meas urement range set the nominal size to zero insert the alignment pin into the lateral hole to align the measurement frame to the 90 position insert the bottom transducer into its holding and push it up against the test plate until the amplifier indicates the required value That value depends on the type of the gauge see gauge card in the documentation and the application 1063 E2 PM5 26 VBM 1063 Operating and Service Manual FRIEDRICH VOLLMER Feinmefigeratebau GMBH 58093 Hagen Verbandsstralke 60 49 2334 507 0 Fax 49 2334 53015 We marked the paragraph with the optimum values for your application Transducers with 1 mm stroke 20 MUBE 0 20 MOBE 0 and meas urement amplifier VMF 3 11 or 3 22 or 3 2000 clamp lower transducer at 500 um Transducers with 1 mm stroke two 20 MUBE 0 and measurement am plifier VMF 3 11 or 3 22 or 3 2000 clamp lower transducer at 800 um If measuring only strip below 1 mm clamp the lower transducer at 500 um Transducers with 2 mm stroke series 90 or 92 20 MUBE 20 MOBE and measurement amplifier VMF 3 2000 clamp lower transducer at 1000 um Transducers with 2 mm s
35. tics With another cable the gauge accuracy might be affected Please do always check the transducer symmetry after a transducer was re inserted see extra manual 1063 E2 PM5 Operating and Service Manual VBM 1063 27 measuring controlling recording automation documentation To check the transducer position The upper guide rollers must be lifted or removed for this check Put the adjustment plate onto the lower guide rollers and tip it to all four directions see sketch 1 through 4 The indicator must be deflected at any time exclu sively towards the side If not the gauge needs service If minus is indicated when the plate is tilted towards one side sketches 1 2 either the transducer tips are worn the C frame is distorted or the lower guide rollers are not parallel If minus is indicated when the plate is tilted towards the front or the back sketches 3 4 itis also possible that the 90 position of measurement frame was not cor rectly adjusted Ifthe indication is deflected to minus theoretically there might be one transducer with a diamond that is not perfectly centred This is easy to check by turning the transducer clockwise in 90 steps Then it is easy to check if the error follows in the same direction when tilting the adjustment plate Symmetry check If there was any soldering done on the cable or the transducer coil check the compensation
36. troke series 90 or 92 two 20 MUBE and measurement amplifier VMF 3 2000 clamp lower transducer at 1500 um If measuring only strip below 1 mm clamp the lower transducer at 500 um for single measurement one transducer and one fixed feeler clamp the transducer so that it measures 0 at the adjustment plate lou oOos Then take off the adjustment plate Gauges with sum measurement select measurement range 10 um fortransducers with micrometer fine adjustment Before inserting screw the upper part of the transducer clockwise down to the limit stop and then turn it back for one full turn connect the second transducer and push it into the upper bore against the lower transducer until the measurement amplifier indicates nearly zero Minor deviations can be eliminated by the zero point potentiometer VMF 3 22 3 22 or the Master key VMF 3 2000 Gauges with single measurement Before inserting screw the upper part of the fine adjustment clockwise down to the limit stop and then turn it back for one full turn push the fine adjustment into the upper bore against the lower trans ducer until the measurement amplifier indicates nearly zero Minor de viations can be eliminated by the zero point potentiometer VMF 3 22 3 22 or the Master key VMF 3 2000 Important note Please do always use a transducer together with its own extension cable which was individually adjusted to the transducer measurement characteris
37. ut the front end of the measurement frame should not move down gauges withsingle measurement one transducer with movable ram and one rigid measurement tip need to have the upper pin screw A screwed clockwise until it touches the C frame Then screw it back for half a turn 180 and lock it When pulling the alignment pin the front end of the C frame should drop for about 1 mm The bottom limit stop screw is always adjusted in such a position that the front end of the C frame can be lifted as far as possible but the transducer scale ring if there is any and the pin G must not touch the housing Turn the lower A screw back for a several turns and lift the front end of the meas urement frame up to its limit stop Hold it there and turn the lower screw A into the housing until it begins to push down the front end of the measure ment frame To assemble the guide rollers First insert the lower guide rollers Their support has to be aligned parallel so that the test plate contacts the rollers at four points For changing the lower guide rollers there is no need to loosen the support But it might be shifted after strip breaking The upper guide rollers are assembled together with their support after the transducers are in correct position To check the transducer alignment Ifthere was any wrong measurement result e g after a strip break the alignment of the transducer clamps should be checked with an inspection bolt avail able