Home

Elite and Reflections Cool Breeze

image

Contents

1. PIPER PRODUCTS Service Manual ELITE AND REFLECTIONS Cool Breeze Refrigerated Tables CB and R CB Models For Service Information call 800 544 3057 Please have the following information available before calling Information can be found on the identification certification tag Model Number Serial Number Date of Purchase Part Description and number as shown in parts list Piper Products Inc 300 South 84 Avenue Wausau WI 54401 Phone 715 842 2724 Fax 715 842 3125 N IMPORTANT INFORMATION READ BEFORE USE 9 3 2015 2 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 Table of Contents INTRODUC HON SR GO GL DR Oa nag OOF 4 EREIGH DAMAGE GL AIMO iic Gn I aa ae eaten 4 INSTALLATION i ee GA GOR reer 5 STARTUP AND OPERATION ee Suite 6 THEORY OF OPERATION UR a dn fedd i 6 THERMOSTAT SET uii iie i Gi aa una 7 STAINLESS STEEL AND GENERAL CLEANING 10 TROUBLESHOOTING GUIDE 5525 Gai al aa AER vu 11 GB EXPLODED VIEW ce NO Exec NU decur G
2. All labor shall be performed during regular working hours Overtime premium will be charged to buyer After thorough examination the decision of the Piper Products Service Department shall be final Any defective parts to be repaired or replaced must be returned to Piper Products Inc 300 South 84th Avenue Wausau WI 54401 transportation charges prepaid and they must be properly packed and tagged The serial and model number of the equipment and date of original installation of such equipment must be given However after one year we will not assume any responsibility for any expenses including labor incurred in the field incidental to the repair or replacement of equipment covered by this warranty Our obligation hereunder to repair or replace a defective part is the exclusive remedy for breach of this warranty and we will not be liable for any other damages or claims including consequential damages If upon inspection by Piper Products Inc or its Authorized Service Agency it is determined that this equipment has not been properly installed or has not been used in an appropriate manner has been modified has not been properly maintained the warranty will be void Also if the nameplate or other identifying marks have been removed defaced or changed or the unit has been repaired or altered by persons other than expressly approved by Piper Products Inc the warranty will be void If the equipment has been subjected to misuse or misapplica
3. C A No 12 EXPEODISD VIEW ue daa ue e Cy wi il er ree 13 WIR ING DIAGRAM cuba resend VE cer GO dded terne FFO 14 PIPER PRODUCTS INC LIMITED 15 3 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 INTRODUCTION Congratulations You have just purchased one of the finest pieces of eguipment on the market today Before installing or operating your new Piper Products Inc equipment you should read through this manual This manual should be retained for further refer ence as it contains installation and operating instructions service tips part lists and warranty information For your safety read and follow all cautions and warnings FREIGHT DAMAGE CLAIMS Your Piper Products eguipment was carefully inspected and packed before leaving our factory The transportation company assumes full responsibility for safe delivery of this eguipment Piper Products cannot assume responsibilities for damage or loss incurred in transit Visible damage or loss should be noted on the freight bill and signed by the person making the delivery A freight claim should be filed immediately with the transportation company If damage is unnoticed or concealed until eguipment is unpacked notify the transportation company immediately and tell them you want to file a concealed
4. HOWN WIRING DIAGRAM IER NEED ES POWER SWITCH INDICATOR LAMP DIXEL ARO6CX CONTROLLER 8598549850 un WR a a a DE P EM PME Gee 2 _ HOT GAS AS SOLENOID aS B pem WATERTIGHT HT SB SA lt v XV EVAPORATOR FANS L ONDENSING 120 VOLT 10 3 AMPS 1236 WATTS 9 3 2015 PIPER PRODUCTS INC LIMITED WARRANTY Piper Products Inc warrants to the original purchaser that its eguipment will be free from defects in the materials and or parts for a period of 12 months from date of shipment and reported to the factory The purchaser is responsible for having eguipment properly installed operated under normal conditions with proper supervision and to perform periodic preventative maintenance Equipment failures caused by inadequate water quality improper cleaning harsh chemicals or acids are not covered under warranty The manufacturers obligation under this warranty shall be the replacement or repair of defective parts within the warranty period Excessive labor more than 1 2 hour required to access Piper equipment built into cabinets tables or structures by others is NOT covered under labor warranty Example Piper multiple or single well food wells
5. ast 30 Does not maintain food Not pre cooled A temperature Were pans of food placed into the unit at or below Food Temperature 38 F Remove pan covers to achieve proper air flow Thermostat Control Is the thermostat control set properly Voltage Call a service technician Indicator light is off and condensing unit does not run N electrical supply Call Piper Products directly at 800 544 3057 if you need further assistance 11 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net CB EXPLODED VIEW 18 1S OF FAN VALVE 1 CM DEFLECTOR PLASTIC CONSULT FACTORY 1501109 6 S S LEG IN LIEU OF CASTERS NOT SHOWN T 7 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25A 25B 26 EN Z _8_ _9_ CH NUN _12_ NN Ea EUM _19_ HN EI ECH 258 E N _ R CB EXPLODED VIEW TN ASSURE WIRE CONNECTION ur IS ON TOP OF FAN ITEM PART NO DESCRIPTION ACCUMULATOR 5 8 CU IN 3 8ODF s FAN TUBEAXALS1SSQSIEM _ s 87 ACRYUC ENDCOOLBREEZE _ s 0955 DIGITAL CONTROL IGFIEMD _ 10 0114525 VALVE SOLENOID 1 4 ODF 120V 11 0112764 DRIER REFRIG 0325 1 4 ODF 13 CSTR 4POPB 4 CASTER WITH BRAKE CORD FAN POWER RPC24 17 _ DEFLECTOR PLASTIC CB CONSULT FACTORY 4501109 6 S S LEG IN LIEU OF CASTERS NOT S
6. be alarms P1 and P2 start some seconds after the fault in the related probe they automatically stop some seconds after the probe restarts normal operation Check connections before replacing the probe Temperature alarms HA and LA automatically stop as soon as the temperature returns to normal values Alarms EA and CA with iF bL recover as soon as the digital input is disabled For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 MAINTENANCE To obtain the best performance from your eguipment it should be cleaned daily and maintained in good condition Z SAFETY ENVIRONMENTAL CAUTION PERSONAL PROTECTION Check your company safety and environmental policy before cleaning or servicing Safety Tip Utilize protective gloves and safety glasses ELECTRICAL POWER become wetted the power switch must be turned to OFF and the unit disconnected from the power source Before performing EXTENDED CLEANING where electrical components can WARNING Do not use any chlorinated or highly caustic cleaners acids ammonia N or other corrosive cleaners These may cause corrosion and or damage to the stainless steel Piper only approves soap and water for cleaning stainless steel Do not allow water to stand in wells for long periods of time Well must be emptied and cleaned after every serving period REQUIRED MONTHLY MAINTENANCE Check that the condenser fan w
7. damage claim This must be done within ten 10 days after delivery was made Be sure to retain all packing material and cartons WARNING Installation of this equipment should be done only by persons qualified or licensed to install electrical eguipment Adjustments and service work should be performed only by a qualified service technician Service is available through Authorized Piper Products Parts and Service Distributors throughout the United States For a complete listing of these call or write Piper Products Inc for the name of the nearest distributor This eguipment is intended for commercial use only Not for household use Use of other than genuine Piper Products replacement parts or service work performed by other than an authorized Piper Products service agent will void the warranty Do not use any corrosive cleaners Piper only approves soap and water for cleaning stainless steel 4 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 INSTALLATION N ELECTRICAL CONNECTION WARNING DO NOT USE EXTENSION CORDS VOIDS WARRANTY Ground The electrical outlet must be provided with an efficient ground and the voltage and the frequency of the electrical line matches those indicated on the data plate w If unsure about the efficiency of the ground have your electrical circuit checked by a qualified technician Supply Voltage When the cooler is operating check that the supply v
8. e it browses the parameter codes or increases the displayed value NO an In programming mode it browses the parameter codes or decreases the displayed value KEY COMBINATIONS NU tz To lock or unlock the keyboard CET 87 Toenterin programming mode SET Toretur to room temperature display LED MODE SIGNIFICATION n On Defrost in progress Dripping in progress Fans output enabled 5 Measurement unit Programming mode For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 HOW TO SEE THE SET POINT 1 Push and immediately release the SET key The set point will be shown 2 Push and immediately release the SET key or wait about 5 seconds to return to normal visualization HOW TO CHANGE THE SETPOINT 1 Push the SET key for more than 2 seconds to change the Set Point Value 2 The value of the set point will be displayed and the C or F LED starts blinking change the set value push the or arrows 4 memorize the new set point value push the SET key again or wait 10 seconds HOW TO START A MANUAL DEFROST Push the DEF key for more than 2 seconds and a manual defrost will start Message Cause Outputs 0 Compressor output according to Cy and Cn Defrost end is timed Minimum temperature alarm Outputs unchanged External alarm Outputs unchanged Serious external alarm All outputs OFF ALARM RECOVERY Pro
9. oltage is not dropping or increasing under over 10 the rated voltage 98 Volts to 127 Volts OR 198 Volts to 243 Volts The manufacturer is not responsible for damages or accidents arising from the misuse or disregard of electrical connections Outside Storage ATTENTION cooler is not designed for outdoor use e cooler should not be stored outside in direct sun or rain Ambient Environmental Conditions e Only locate the cooler in a maximum condition of 80 F 27 C and 60 Relative Humidity Positioning e Keep away from heat sources such as radiators or air conditioning pipes e The ambient temperature must not be higher than 80 F 27 C Air Flow e When installing unit make sure there is a minimum of 2 inches air space at the louvered panel located at the end of the unit e 12 inches air space at the louvered panel front and rear of the cabinet Cooler Leveling e To provide the best performance the cooler must remain level 5 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 START UP AND OPERATION OPERATING THE COOLER Before Operating the Cooler e Ensure that the electrical outlet is connected effectively to earth ground suitable to provide the voltage indicated on the data plate e Ensure proper air flow to the front rear and sides e Ensure the cooler is level Electrical Service Switch Turn the control panel switch to the ON position e The pilo
10. orks properly Check thermostat settings Check operating temperature of unit Clean entire refrigerated case Clean condenser coils Check and clean drainage lines Check electrical connection Check the evaporator fan 2 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 STAINLESS STEEL AND GENERAL CLEANING Stainless Steel and Aluminum e Piper only approves soap and water for cleaning stainless steel e NOTICE Do NOT use chlorinated cleaners General Surfaces Fiberglass e Clean surfaces with a soft cloth or sponge utilizing a mild detergent Rinse completely with warm water and then dry e NOTICE Do NOT use steel wool Hardened Foods or Scale Deposits e Clean hardened foods or scale deposits by utilizing a plastic scouring pad and a mild detergent Rinse completely with warm water and dry e NOTICE Do NOT use steel wool CLEANING CONDENSING UNIT CB NOTICE FAILURE TO PROPERLY CLEAN THE CONDENSER WILL VOID THE WARRANTY Monthly cleaning of the condensing unit is essential for product temperature and refrigeration system performance Cleaning Method e WARNING Disconnect electrical power to the cooler by turning master switch to the OFF position and unplugging cooler from electrical receptacle e Remove the louvered panels from the condensing unit compartment e Clean condenser by using a brush and vacuum cleaner to remove all dust and dirt CAUTION The fins on the conden
11. sing unit coils are sharp Safety Tip Utilize protective gloves and safety glasses WARNING Refrigerant is under high pressure Do NOT bend kink or damage any tubing or condensing unit coil 10 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 TROUBLESHOOTING GUIDE problems are not found by the following checks then you should contact your Authorized Parts and Service Dealer for service They have the necessary parts and training to repair your unit guickly and efficiently N DANGER Disconnect all power to unit before servicing Symptoms Possible Cause Is the unit plugged in Check circuit breaker and fuse Check switch on control panel is in on position Call a service technician Indicator light is on but condensing unit does not run Thermostat Control Is the thermostat control set properly Are there heating or A C ducts make up air ducts or Ducting fans causing cool drafts Has the unit been allowed to pre cool for at least 30 Unit does not cool to proper Not pre cooled wines temperature Thermostat Control Is the thermostat control set properly Voltage Call a service technician Check condenser and evap coils for proper air flow Ductin Are there heating are A C ducts make up air ducts 9 or fans causing cool drafts Food longer than 4 Food should not be kept in CB units for long periods hours of time o Has the unit been allowed to pre cool for at le
12. t light will light and the condensing unit will start e Note After 30min the bottom of the cold pan should be cold to the touch and start to frost over Energy Savings Product Performance Location Tips e When possible DO NOT place the cooler near air conditioning vents or returns e When possible place the cooler the maximum distance from the exit or entrance door THEORY OF OPERATION The Cool Breeze Table CB R CB is designed to display cold foods and salads during the meal period NOTE Cold Food Tables are NOT refrigerators and will NOT keep food N cold for long periods of time Food should always be placed into the table directly from the refrigerator When the food in the table reaches a temperature of 38 to 40 Fahrenheit it should be placed back into the refrigerator and replaced with cold food from the refrigerator um AIRFLOW DIRECTION _J ihn tU PAN LEDGE 3 EVAPORATORCOL C FIN amp m T Fp pr qum AIRFLOW DIRECTION jm STAINLESS STEEL LINER 6 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 THERMOSTAT SETTINGS The thermostat has a preset temperature of 39 Fahrenheit with a 4 differential from the factory To display target set point In CET programming mode it selects a parameter or confirms an operation ate To start manual defrost In programming mod
13. tion neglect abuse accident damage during transit or delivery fire flood riot or acts of God then this warranty shall also be void When any situation occurs which voids the warranty the manufacturer shall not be liable for any damage to any person or any property which may result from the use of the equipment thereafter Warranty is limited to Piper manufactured products only and does not apply to other equipment which may be connected to or installed within No representative dealer distributor or any other person is authorized or permitted to make any other warranty or obligate Piper Products Inc to any liability not strictly in accordance with this policy This warranty is in lieu of all other warranties expressed or implied including any warranty of merchantability and fitness for a particular purpose Piper Products does hereby exclude and shall not be liable to purchaser for any consequential or incidental damages including but not limited to damages to property damages for loss of use loss of time loss of profits or income resulting from any breach of warranty 15 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net 9 3 2015 16 PIPER PRODUCTS 300 South 84 Avenue Wausau WI 54401 Phone 715 842 2724 Fax 715 842 3125 For Tech Support call 800 544 3057 Fax 715 842 3125 www piperonline net

Download Pdf Manuals

image

Related Search

Related Contents

Capitolato tecnico [file]  PCIe-COM232-8 - ACCES I/O Products, Inc.  Téléchargez la fiche  Axing SPU 910-09  Dynamic Contact Angle Analyzer Tutorial  Assembly manual, Sample pages  "user manual"  Blue Rhino CBC701W User's Manual  Samsung Galaxy S Advance NFC Uživatelská přiručka  FOUNDATION フィールドバス対応 スマート・バルブ  