Home

High Wall Inverter

image

Contents

1. 20K 1 390000595 7 Sensor insert 1 42020063 8 Receiver Board JKD 1 30046074 9 Wire Clip 1 42012415 10 Wire Clamp 1 71010103 11 Electric Box 1 20102186 12 Transformer 48X26G 1 43110233 13 Main PCB 1 30030120 14 Wire Slot 1 70482001 15 Terminal Board T4B3A 1 42011233 16 Electric Box Cover 1 1 20102187 17 Room Sensor 15K 1 390000451 18 Front Case 1 20002119 19 Electric Box Cover 2 1 20102188 20 Filter 2 11122016 21 Front Panel Link 2 10582026 22 Front Panel Dowel 2 10562002 23 Front Panel Crank 2 10562001 24 Stepping Motor MP24GB 2 15212111 25 Front Panel 1 20002076 26 Front Panel Holder 1 01792006 27 lOrnamental Bar 1 68012022 28 Pilot Lamp Frame 1 26112045 29 Pilot Lamp Panel 1 22432066 30 Button Panel 1 26112046 31 Evaporator Flashboard 1 010723101 32 Evaporator Support 1 24212028 33 Water Tray 1 20182032 34 Swing Link 1 1 10582024 35 SwingLlink2 1 10582025 36 Swing Louver 10 10512043 37 Guide Louver 1 10512042 38 Guide Louver Bearing 3 10542011 39 Connecting Cable 1 400205235 40 41 Drainage Pipe 1 052324111 42 Stepping Motor MP24GA 1 15212102 43 Evaporator Assy 1 01002221 44 Fan Bearing 1 76512210 45 Ring of Bearing 1 76512203 46 CrossFlow Fan 1 10352004 47 Remote Controller Y512F 1 30515002 48 Power Cord 1 40022011 49 Shield Box of Electric Box Assy 1 01592024 50 Shield Box of Electric Box Assy 1 01592032 All data subject to change without notice Spare
2. parts Indoor unit YVKC 12 31 32 RM oie HR 34 i 00 000 00 36 o We x 39 40 41 42 All data subject to change without notice Spare parts Indoor unit YVKC 12 No Description Qty Part Code Exploded View Product Code 1 Wall Mounting Frame 1 01252001 2 Pipe Clamp 1 24242001 3 Rear Case 1 22202327 4 Motor FN20Y 1 15012068 5 Motor Clamp 1 22242034 6 Tube Sensor 20K 1 390000595 7 Sensor insert 1 42020063 8 Receiver Board JKD 1 30046074 9 Wire Clip 1 42012415 10 Wire Clamp 1 71010103 11 Electric Box 1 20102186 12 Transformer 48X26G 1 43110233 13 Main PCB 1 30039131 14 Wire Slot 1 70482001 15 Terminal Board T4B3A 1 42011233 16 Electric Box Cover 1 1 20102187 17 Room Sensor 15K 1 390000451 18 Front Case 1 20002119 19 Electric Box Cover 2 1 20102188 20 Filter 2 11122016 21 Front Panel Link 2 10582026 22 Front Panel Dowel 2 10562002 23 Front Panel Crank 2 10562001 24 Stepping Motor MP24GB 2 15212111 25 Front Panel 1 20002076 26 FrontPanel Holder 1 01792006 27 lOrnamental Bar 1 68012022 28 Pilot Lamp Frame 1 26112045 29 Pilot Lamp Panel 1 2
3. system switches be tween cool and heat modes automatically if the ambient temperature is above or below the set point The unit operates in cool mode if the ambient temperature is above the set point and in heat mode if it is below said set point This is the operating mode recommended 3 Adjusting ambient temperature Press the or buttons to change the ambient temperature set point This should remain between 16 and 30 C To select fan speed and air louver posi tion Speeds available are Low Medium High Press the FAN button to achieve the desired air flow The FAN symbol shows the speed selected Use the SWING button to control the air louvers If pressed once the louvers are sta tionary if pressed a second time the louvers sweep to distribute air throughout the room 4 Timer operations The control unit is equipped with a timer that sets the on and off times of the unit The configurations stored in the control unit will be the predominating parameters upon turning the unit on To use the timer proceed as follows On off timer The on off timing function is achieved by pressing the TIMER button To start the unit at a determined time press the TIMER but ton in half hour intervals until the on time is achieved The unit will start once the pro grammed time has elapsed which will be memorised by the unit In the same way to turn the unit off at a de termined time carry out the same operation by pre
4. 1 RoomTemperature Sensor 15K 1 3900012123 32 TubeTemperature Sensor 20K 1 39000071 33 Exhaust Gas Temperature Sensor 50K 1 39000016 34 Electric Box Cover 1 01413048 35 Power Module 1 32210093 36 Recti er S25VB60 2 46010602 37 Sensor Insert 1 42020063 38 Radiator 1 49010212 39 Rear Grill 1 01473030 40 Condenser Assy 1 01103587 41 Top Cover 1 01253443 42 Motor Support 1 01703391 43 Reactor L16 5mH 10A 14 650 1 43130169 44 Reactor Box B 1 01413503 45 Motor FW30K 1 15013067 46 Axial Flow Fan 1 10333413 47 Nut 1 70310131 48 Front Grill 1 22413431 All data subject to change without notice Operating and maintenance instructions HORIZONTAL SWING AUTOMATIC ROTATION OF VERTICAL LOUVERS Infrared ray remote control unit FAN SPEED LCD E FAN AUTOFAN oper ON OFF PROGRAMMER Note Use alkaline AAA batteries only AUTO E 49 3e 3t SLEEP 9C AR RE BACTERIA LI PURIF AUTO AUTO FAN HUMID adl Y D EB 22H lt a SPEED 1 TIMER ONOFF VERTICAL SWING AUTOMATIC ROTATION OF HORIZONTAL IC 3 LOUVERS E DISPLAY LIGHT C3 LIGHT RE BACTERIA TEMPERATURE NOT IN USE SETTING c C C3 SELECCI N DE MODO SLEEP MODE COOL DRY HEAT AUTO 6 f m X A y ON OFF 1 The ON OFF button allows turn ing the air co
5. 2432066 30 Button Panel 1 26112046 31 Evaporator Flashboard 1 010723101 32 Evaporator Support 1 24212028 33 Water Tray 1 20182032 34 Swing Link 1 1 10582024 35 Swing Link 2 1 10582025 36 Swing Louver 10 10512043 37 Guide Louver 1 10512042 38 Guide Louver Bearing 3 10542011 39 Connecting Cable 1 40020538 40 41 Drainage Pipe 1 052324111 42 Stepping Motor MP24GA 1 15212102 43 Evaporator Assy 1 01002187 44 FanBearing 1 76512210 45 Ring of Bearing 1 76512203 46 Cross Flow Fan 1 10352004 47 Remote Controller Y512F 1 30515002 48 Power Cord 1 400204643 49 Shield Box of Electric Box Assy 1 01592024 50 Shield Box of Electric Box Assy 1 01592032 All data subject to change without notice Spare parts Outdoor unit YVJC 09 40 42 41 43 44 32 33 51 EW 77 peed All data subject to change without notice Spare parts Outdoor unit YVJC 09 No Description Qty Part Code Exploded View US Product Code 1 Front Panel 1 01533005 2 Clap Board 1 01233381 3 Reactor Box C 1 01413504 4 Reactor 1004 1 43130165 5 Drainage Connecter 1 06123401 6 Reactor Support 1 01213429 7 Overload Protector 1 00180039 8 Compressor E
6. 42 41 43 44 Um 45 OE TS SY Ma Ga 46 51 32 35 SLSINS SIS AES N 47 48 ct to change without notice All data subje Spare parts Outdoor unit YVJC 12 No Description Qty Part Code Exploded View ENG Product Code 1 Front Panel 1 01533005 2 Clap Board 1 01233381 3 Reactor Box C 1 01413504 4 Reactor L004 1 43130165 5 Drainage Connecter 1 06123401 6 Reactor Support 1 01213429 7 Overload Protector 1 00180039 8 Compressor EU1011DV 1 00100125 9 Compressor Gasket 3 76710238 10 Bolt 3 70212014 11 Nut 3 70310014 12 Walve Support 1 01713041 13 Right Side Plate 1 01303048 14 Valve 1 2 1 07100006 15 Valve 1 4 1 07100003 16 Capillary Assy 1 03103191 17 M4 Way Valve 1 430004032 18 4 way Rever sing Valve Component 1 03023234 19 Big Handle 1 26233433 20 4 way Valve Coil 1 430004002 21 WireClap 1 71010102 22 Insulation Piece D 1 70410525 23 Terminal Board A 1 42011113 24 Capacitor CBB61 2 5uF 450V VDE 33010026 25 Electric Box 2 1 01413051 26 Capacitor 2200uF 20 400V 1 33010803 27 Capacitor CBB60A 20uF 400V 10 1 33010057 28 Capacitor 100uF 400V 10 1 33310054 29 Electric Box A 1 20103501 30 PCB W923HB 1 30039244 3
7. D extinguishs for 3 seconds then flicker 8 times Anti cooling protection Heating mode start up E9 The LED extinguishs for 3 seconds then flicker 9 times Reduce running frequency when the AC voltage falls down In EO nm N verter The LED extinguishs for 3 seconds then flicker 10 times No response from indoor motor H6 The LED extinguishs for 3 seconds then flicker 11 times Indoor ambient sensor short circuit or open circuit F1 The LED extinguishs for 3 seconds then flicker 1 times Indoor tube sensor short circuit or open circuit F2 The LED extinguishs for 3 seconds then flicker 2 times Outdoor ambient sensor short circuit or open circuit F3 The LED extinguishs for 3 seconds then flicker 3 times Outdoor tube sensor short circuit or open circuit F4 The LED extinguishs for 3 seconds then flicker 4 times Outdoor ambient sensor short circuit or open circuit F5 Cooling mode LED indicator The LED extinguishs for 3 seconds then flicker 5 times Reduce running freguency to protect overload in cooling mode F6 The LED extinguishs for 3 seconds then flicker 6 times Oil return problem F7 The LED extinguishs for 3 seconds then flicker 7 times Reduce running freguency in overcurrent condition inverter F8 The LED extinguishs for 3 seconds then flicker 8 times Reduce running frequency when discharge temperature is F9 The LED extinguishs for 3 seconds then flicker 9 times overhigh Inverter Defrosting problem H1 The LED extinguishs for 3 second
8. Drain tray and pipe 1 Clean and make sure there are no obstructions Every season prior to start up Trouble shooting Problem Possible cause and correction A Air conditioning unit inoperative 1 Make sure fuse is not blown out or main switch has not been activated 2 Is main switch set to OFF 3 Has any mistake been made when programming B Unit does not cool sufficiently 1 Is the filter dirty See instructions on how to clean filter 2 The room was probably too warm when turning the unit on Wait until the unit has had time to lower the room temperature 3 Has the adequate temperature been programmed 4 Are the unit air intake or outlet grids obstructed C There is a bad odour in the room 1 Make sure said odour is not from dampness of walls carpets furniture or other fabrics in the room D Air conditioning unit makes noise 1 A noise similar to running water Caused by refrigerant liquid going through refrigerant circuit 2 A noise similar to a shower Caused by dehumidification water treated inside the unit E Seems as if condensed water is flowing from the unit 1 Condensation is produced when the unit cools the air in the room F Air conditioning unit inoperative 3 minutes after reset 1 Due to a system protecting device Wait 3 minutes for operation to start again G The remote control display becomes weak or goes off 1 The batteries may
9. ECIFICATIONS APPLIED EN ISO 9001 Pr EN378 PLACE Sabadell Espa a SIGNATURES ROMAN ARRODA QUALITY CONTROL MANAGER ES oet CONTROLS www johnsonc TI YVHC 09 12GB 03 07
10. High Wall Inverter YVHC 09 to 12 SERVICE MANUAL YVHC 09 YVHC 12 al YORK cy TI YVHC 09 12GB 03 07 Fig 1 E CALEFACCION REFRIGERACION DESHUMIDIFICACION HEAT COOL DRY CHAUD FROID DESHUMIDIFICATION D AQUECIMENTO REFRIGERACAO DESHUMIDIFICACAO RISCALDAMENTO RAFREDAMENTO DEUMIDIFICAZIONE HEIZEN KULEN ENTFEUCHTEN lo VERWARMING KOELING ONTVOCHTIGING OPPVARMING AVKJOLIG AVFUKTNING MARCHA O AUTOMATICO ON AUTO MARCHE AUTOMATIQUE LIGACAO AUTOMATICO ACCESO AUTOMATICO EIN AUTOMATICBETRIEB AAN AUTOMATISCH BEDRIJF PA AUTOMATISK gt 30 cm SAT A K Fig 2 Fig 3 Fig 4 Fig 5 N 0g 04 NZ p 90 90 Fig 6 Fig 7 1 Panel frontal Front panel Panneau frontal Painel frontal Pannello frontale Frontblende Frontpaneel Frontpanel 2 Filtros Filters Filtres Filtros Filtri Filter Filters Filtre Tapa de conexiones el ctricas Wire connection cover plate Couvercle de connexions lectriques Tampa de conex es el ctricas Coperchio dei collegamenti elettrici Abdeckung elektrische Anschl sse Deksel voor elektrische aansluitingen Lokk over elektriske koblinger 4 Cable de alimentaci n Power supply cable C blage d alimentation Cabo de alimentac o Cavo d alimentazione Speisakabel Nets
11. TOR STEP MOTOR POWER 220 230 240V 50 60Hz EFT Richt MOTOR 230 40 BN HZ SBL S XT LIGHT BL N a 28K peal S Lim 1BN en O 5 5 AP2 E N 4YE GN U 22 ROOM TUBE amp TC EVAPORATOR ELECTRIC BOX RTI RT3 NO Ne ROOM PIPE TRANSFORMER INDOOR UNIT TEM SENSOR TEM SENSOR Outdoor units YVJC 09 12 reu SENSOR TENSENGOR TE SENSOR 3YE GN H n X606 X603 A A JA La XT2 609 x615 Xei4 X63 D gt E wa ES R X610 AP4 Lv X627 X604 607 X628 M id X621 UC N X621 CJ 7 1608 318000 X602 X60Is XO0l 18H 18K N OR OR Uf 158U 44WH 120R ere RT DN a A 22wH Ct 2200uF 12 1004 TRANSFORMER CX 100uF C4 2 5uF All data subject to change without notice Spare parts Indoor unit YVKC 09 All data subject to change without notice Spare parts Indoor unit YVKC 09 No Description Qty Part Code Product Code YVKC 09 1 Wall Mounting Frame 1 01252001 2 Pipe Clamp 1 24242001 3 Rear Case 1 22202327 4 Motor FN20Y 1 15012068 5 Motor Clamp 1 22242034 6 Tube Sensor
12. U1011DV 1 00100125 9 Compressor Gasket 3 76710238 10 Bolt 3 70212014 11 Nut 3 70310014 12 Valve Support 1 01713041 13 Right Side Plate 1 01303048 14 Valve 3 8 1 07100005 15 Valve 1 4 1 07100003 16 Capillary Assy 1 03103018 17 4 Way Valve 1 430004022 18 4 way Rever sing Valve Component 1 03023671 19 Big Handle 1 26233433 20 4 way Valve Coil 1 43000400 21 Wire Clap 1 71010103 22 nsulation Piece D 1 70410525 23 Terminal Board A 1 42011113 24 Capacitor CBB61 2 5uF 450V VDE 33010026 25 Electric Box 2 1 01413051 26 Capacitor 2200uF 20 400V 1 33010803 27 Capacitor CBB60A 16uF 400V 10 1 33010054 28 Capacitor 100uF 400V 10 1 33310054 29 Electric Box A 1 20103501 30 PCB W923HAA 1 30039243 31 RoomTemperature Sensor 15K 1 3900012123 32 Tube Temperature Sensor 20K 1 39000071 33 Exhaust Gas Temperature Sensor 50K 1 39000016 34 Electric Box Cover 1 01413048 35 Power Module 1 32210096 36 Recti er S15VB60 2 46010601 37 Sensor Insert 1 42020063 38 Radiator 1 49010212 39 Rear Grill 1 01473030 40 Condenser Assy 1 01103532 41 Top Cover 1 01253443 42 Motor Support 1 01703020 43 Reactor L16 5mH 10A 14 650 1 43130169 44 Reactor Box 1 1 01413035 45 Motor FW30K 1 15013067 46 Axial Flow Fan 1 10333414 47 Nut 1 70310131 48 Front Grill 1 22413431 All data subject to change without notice Spare parts Outdoor unit YVJC 12 40
13. given on the need to clean the air filter periodically gt Op p The guarantee card has been filled out Maintenance instructions have been given or a contract has been made for periodical serv icing gt ATTENTION A Your product is marked with this symbol This means that at the end of its service life it should not be mixed with other non classified household waste Therefore disposal should be carried out in compliance with the corresponding local and national regulations in a correct and environment friendly manner The dismantling of the air conditioning unit as well as the processing of refrigerant oil and other compo nents should be carried out by a qualified technician and in compliance with the applicable legislation Contact your local authorities for further information Wiring Fig 8 Models YVKCO9DS YVKC12DS POWER SUPPLY 230 1 Ph 50 Hz AZ T E 1 LEN LL N 1 T L 2 NG N 1 4 a GROUND TERMINAL CLAMP INDOOR UNIT OUTDOOR UNIT MA BROWN AM V YELLOW GREEN AZ BLUE RJ RED AM YELLOW NG BLACK All data subject to change without notice Connection Schema Indoor units YVKC 09 12 STEP MO
14. hysikalische Angaben Fysieke gegevens Fysiske data Modelo Model Modele Modelo Modello Modell Model Modell YVKCO9DS AAA YVKC12DS AAA Caudal Flow D bit Caudal Portata Durchsatz Luchtdebiet Strom Velocidad alta High speed mh 450 500 Grande vitesse Velocidade elevada Velocita alta Hohe Geschwindigkeit Hoge snelheid Hay hastighet mYs 0 13 0 14 Control Control Contr le Controlo Infrarrojos Infrared rays Infrarouges Infravermelhos Comando Bedienung Regeling Kontroll Infrarossi Ir Infrarood Infrarod Conexiones frigor ficas Cooling connections Liaisons frigorifiques Ligac es frigor ficas Collegamenti frigoriferi K lteanschlisse Koelaansluitingen Kjelekoblinger Diametro mayor Larger diameter Diam tre le plus grand 9 52 127 Di metro maior Tubo di diam maggiore mm 3 8 1 2 Durchm dickes Rohr Grootste diameter Storste diam Diametro menor Smaller diameter Diam tre le plus petit 6 35 6 35 Di metro menor Tubo di diam minore mm 1 4 1 4 Durchm d nnes Rohr Kleinste diameter Minste diameter Peso aproximado Approximate weight Poids approximatif Peso aproximado Peso approssivativo Ungef hres Gewicht Gewicht ong Tiln rmet vekt Neto Nett Net L quido Netto Netto Netto Netto kg 11 11 Bruto Gross Brut Bruto Lordo Brutto Bruto Bru
15. nditioning unit on or off 2 Setting operating mode There are five operating modes available System operating mode can be set by press ing the MODE button in the following se quence Automatic Cool Dehumidification Vent Heat Vent mode In FAN mode only the fan is operative Fan speeds low medium high auto can be selected If AUTO is set in cool or heat mode fan speed will change in low medium high se quence or high medium low automatically depending upon the differential between the ambient temperature and the set points Dehumidification mode In DRY mode if the ambient temperature is above the set point the unit will operate in cool mode with the fan on AUTO If the am bient temperature is below this set point the compressor and fan ON OFF periods will go to a fixed repetition cycle depending upon the differential between the ambient tem perature and the set point Cool mode In COOL mode low medium high auto fan speeds can be set Heat mode In HEAT mode low medium high auto fan speeds be set In order to avoid cold air originating in the unit in heat operation when the coil tem perature is too low the fan will stop As the coil temperature rises as a result of com pressor operation the fan restarts This fea ture is also operative when the unit is turned on delaying fan operation until the tempera ture has reached the selected value Auto mode In AUTO mode the
16. need changing 2 Do not invert polarity of the batteries when changing H Air conditioning unit does not respond to remote control unit or to direct manual control 1 The batteries may need changing 2 Do not invert polarity of the batteries when changing 3 Contact your authorized Service Centre to have them check the power supply of your installation LED codes in High Wall and cassette units Failures description or protection behavier clea Indoor LED Behavier HP Protection E1 The LED extinguishs for 3 seconds then flicker 1 times When inner tube temperature is low the preset program will cut E2 Tke LED Bidinguisher r 8 seconde inen Dicker 2 m s off compressor meanwhile the inner motor won t stop 9 System low pressure protection Lp Bp protection The LED extinguishs for 3 seconds then flicker 3 times Compressor discharge protection E4 The LED extinguishs for 3 seconds then flicker 4 times Overcurrent protection in low voltage situation E5 The LED extinguishs for 3 seconds then flicker 5 times Communication failure E6 Running LED indicator The LED extinguishs for 3 seconds then flicker 6 times Mode collision E7 The LED extinguishs for 3 seconds then flicker 7 times Anti high temperature protection E8 The LE
17. ositions The drain line should include an elbow U shaped Fig 4 Connect a plastic con densed water drain pipe with a 12 mm in ner diameter The drain pipe should be fastened to the cooling lines with vinyl tape see Fig 6 Typical installation Fig 1 This illustration shows in general a typical installation of this equipment After carrying out a drain test apply vinyl tape ref 3 joining all tubing Wiring 1 Open the front panel 2 Remove the wiring cover 3 Locate the connecting cable from the indoor unit passing though the connect ing hole 4 Connect the blue power supply cable to terminal N 1 the brown cable to 2 and the yellow green cable to the ground connection as indicated in Fig 8 5 For heat pump models connect the power supply cables as indicated in Fig 8 and fasten the cable to the casing 6 Install the electrical connection protec tor 7 Mount the front panel Cable section Sizes YVKCO9DS YVKC12DS Power supply mm 3x2 5 3x2 5 Interconnection ind out 4x2 5 4x2 5 Fuse K Curve A 10 Prior to final approval of the installation Check The voltage is always between 198 254 V The power supply cable section is at least that recommended Condensed water drainage is carried out correctly and there are no leaks in the water circuit Operating instructions have been given to the user Information has been
18. panningkabel Mateleding G Cinta vinilo Vinyl tape Ruban de vinyle Fita de vinilo Nastro vinilico Klebeband Vinyltape Vinyltape Mando a distancia Remote control unit T l commande Comando a distancia Telecomando Fernbedienung Afstandsbediening Fjernkontroll Manguera de desag e Drain hose Tuyau de drainage Mangueira de desaguamento Tubo scarico condensa Kondensatablauf Afvoerslang Avlopsslange Lineas frigorificas Cooling lines Lignes frigorifigues Linhas frigorificas Tubazioni frigorifere K lteleitungen Koelleidingen Kjolelinjer Cable de interconexi n Interconnecting cable C blage d interconnexion Cabo de interligac o Cavo di collegamento Verbindungskabel Aansluitkabel Forbindelsesledninger 10 Salida aire Air outlet Sortie d air Saida de ar Uscita d aria Luftaustritt Luchtuitlaat Luftutlop Salida lateral de lineas de refrigerante Refrigerant line side outlet Sortie lat rale dans lignes de r frig rant Saida lateral das linhas de refrigerante Uscita laterale per i tubi del refrigerante Seitlicher Austritt der Kalteleitung Zijuitgang koellijnen Sideutlop av kjelelinjer Dimensiones generales General dimensions mm Dimensions g n rales Dimens es gerais Dimensioni d ingombro Algemeine abmessungen Algemene afmetingen Generelle dimensjoner YVKCO9DS AAA YVKC12DS AAA Datos f sicos Physical data Donn es physiques Dados f sicos Dati tecnisi P
19. s then flicker 1 times Electrostatic dusting protection H2 The LED extinguishs for 3 seconds then flicker 2 times Compressor Overload protection H3 The LED extinguishs for 3 seconds then flicker 3 times System abnormally H4 The LED extinguishs for 3 seconds then flicker 4 times Module protection H5 Heating mode LED indicator The LED extinguishs for 3 seconds then flicker 5 times Synchronous failure H7 The LED extinguishs for 3 seconds then flicker 7 times Water is full H8 The LED extinguishs for 3 seconds then flicker 8 times Electric heating tube malfunction H9 The LED extinguishs for 3 seconds then flicker 9 times Reduce running frequency anti high temperature in heating mode HO T N Inverter The LED extinguishs for 3 seconds then flicker 10 times Reduce running freguency when tube temperature is overhigh FA Inverter Reduce the running freguency for Anti icing Inverter FH ATTENTION Your product is marked with this symbol This means that at the end of its service life it should not be mixed with other non classified household waste Therefore disposal should be carried out in compliance with the corresponding local and national regulations in a correct and environment friendly manner The dismantling of the air conditioning unit as well as the processing of refrigerant oil and other compo nents should be carried out by a gualified technician and in compliance with the applicable legislation Contac
20. ssing the TIMER button as many times as necessary to achieve the required time 5 Sleep function The Sleep mode which can be used in Cool and Heat is a program that controls the ambient temperature at night Cool mode In Sleep mode and cool operation the unit will operate in the following phase se quence 1 2 Phase 1 The unit will operate in cool mode until the ambient temperature set point is reached Phase 2 After reaching the ambient tem perature set point the unit will operate in cool mode so as to keep the ambient temperature within the limits of the set point 1 to 2 C for 1 hour Heat mode In Sleep mode and heat operation the unit will operate in the following phase se quence 1 2 Phase 1 The unit will operate in heat mode until the ambient temperature set point is reached Phase 2 After reaching the ambient tem perature set point the unit will operate in heat mode so as to keep the ambient temperature within the limits of the set point 1 to 2 C for 1 hour Operating Control Emergency operation The emergency switch is located in the re ceiving panel on the front of the unit This switch is used when the batteries of the re mote control unit have run out or in the case of any trouble Operation of the system in Emergency mode Cool System The ambient temperature set point is set to 20 C The unit operates in the cool mode Heat and Cool System The ambient temperature se
21. t point is set to 25 C The unit operates in automatic mode Automatic reset and antifreeze protec tion After any power failure the unit resets au tomatically when power supply is re estab lished remaining in the same mode as prior to the failure Defrost and overheating protection This feature is used to avoid freezing of the evaporating unit in cool or dry mode as well as to avoid overheating in heat mode When in the defrost antifreeze and over heating protection cycle the compressor is inoperative its LED flashes in cycles and the air louver stops in fully open position At the end of this cycle the louver operates in accordance with the previously programmed parameters Maintenance These units are designed to operate during long periods of time with minimum mainte nance Nevertheless the following opera tions should be carried out regularly Component Maintenance Frequency recommended Dust filter Clean with a vacuum cleaner or tap lightly and wash with luke warm water 40 and mild detergent Rinse and dry before reinstalling on unit Do not use gasoline alcohol or other chemical products Every month more frequently if necessary Unit casing 1 Remove dust from front panel with a soft rag or a rag mois tened in a mild soapy solution 2 Do not use gasoline alcohol or other chemical products Every month or more frequently if necessary
22. t your local authorities for further information All data subject to change without notice DECLARACION CE DE CONFORMIDAD SOBRE MAQUINAS FABRICANTE CLIMA ROCA YORK S L DIRECCION Paseo Espronceda 278 08204 SABADELL La m quina corresponde a las exigencias b sicas de la Directiva de la CE sobre m quinas Directiva CE 89 392 CEE incluidas las modificaciones de la misma y la correspondiente transposici n a la ley nacional APLICACI N DE LA M QUINA AIRE ACONDICIONADO REFRIGERACION DIREC TIVAS DE CNCE APLICADES 89 392 EEC 89 336 EEC 73 23 EEC NORMAS ARMONIZADAS APLICADAS EN292 1 EN292 2 EN 60335 1 EN60335 2 40 EN55104 1 EN55104 2 EN61000 3 2 EN61000 3 3 NORMAS INTERNACIONALES Y ESPECIFICACIONES T CNICAS APLICADAS EN ISO 9001 Pr EN378 LUGAR Sabadell Espa a FIRMA ROMANJARRODA JEFE CONTROL DE CALIDAD DECLARATION OF COMPLIANCE ON MACHINERY MANUFACTURER CLIMA ROCA YORK S L ADDRESS Paseo Espronceda 278 08 204 SABADELL This machine complies with the basic demands of the EC Standards on machinery Standard EC 89 392 CEE including any modification of same APPLICATION OF THE MACHINE AIR CONDITIONER COOLING TYPE YVKCO9DS AAA YVKC12DS AAA EC STANDARDS AFPLIED 89 392 EEC 89 336 EEC 73 23 EEC MATCHING STANDARDS APPLIED EN292 1 EN292 2 EN 60335 1 EN60335 2 40 EN55104 1 EN55104 2 EN61000 3 2 EN61000 3 3 INTERNATIONAL STANDARDS AND TECHNICAL SP
23. too kg 13 18 Installation Instructions Inspection Upon reception inspect the equipment and notify both the carrier and the insurance company in writing of any possible dam age Environmental protection Eliminate packing in accordance with the regulations in force on en vironmental conservation Installation of indoor unit Fasten the mounting plate to the wall Tighten screws slightly Level the mounting plate and then tighten screws to a maxi mum Fig 2 If the tubing goes through the back of the unit drill a 50 mm diameter hole in the wall The outer side of this hole should be slightly below the inner side Figs 3 and 7 Install the through guide The refrigerant lines can be installed in dif ferent positions Fig 6 Installation of the interconnecting tubing and wiring with the central mounting plate located at the back of the chassis Hang the upper part of the unit over the mounting panel and press forward Fasten the indoor unit to the mounting plate per manently Bend the tubing carefully without flattening or obstructing it Pass the tubing and cables of the unit through the hole and hand the upper part of the indoor unit on the upper edge of the mounting plate see Fig 2 Make sure the unit is installed properly moving it first to the left and then to the right Condensed water drain The drain pipe of the unit is flexible and can be placed in different p

Download Pdf Manuals

image

Related Search

Related Contents

ATC550 Antenna Control Unit Installation Manual  SoundStation Duo Conference Phone Quick Start Guide  Princess 221201 mixer  2 Year Guarantee Statement  Smussatrice AT-200    Canon 5252B001AA Printer User Manual  Philips CD-R CR7D5QB10  INSTRUCCIONES DE INSTALACIÓN Y FUNCIONAMIENTO  Manual da Cyber-shot  

Copyright © All rights reserved.
Failed to retrieve file