Home
Agilent RF Network Analyzers PNA Series
Contents
1. Verification Kits All Agilent Technologies verification kits include e precision Z airline e mismatched airline e fixed attenuators e traceable measured data and uncertainties O 85055A 300 kHz to 18 GHz Type N kit Includes attenuators and mismatch attenuator with data on a 3 5 inch disk for use in confirming accuracy enhanced system measurement performance traceable to national standards Test procedure is provided in the service manual O 85053B 300 kHz to 26 5 GHz 3 5 mm kit Includes attenuators and mismatch attenuator with data on a 3 5 inch disk for use in confirming accuracy enhanced system measurement performance traceable to national standards Test procedure is provided in the service manual Adapters O 11853A 50 ohm Type N accessory kit Includes 1250 1472 Type N f to Type N f adapter two included 1250 1475 Type N m to Type N m adapter two included 11511A Type N short 11512A Type N m short O 11878A Type N to 3 5 mm adapter kit Includes 1250 1744 3 5 mm f to Type N 50 ohm m adapter 1250 1743 3 5 mm m to Type N 50 ohm m adapter 1250 1745 3 5 mm f to Type N 50 ohm f adapter 1250 1750 3 5 mm m to Type N 50 ohm f adapter O 11524A 7 mm to Type N f adapter O 11525A 7 mm to Type N m adapter O 11906A 7 16 to 7 16 Includes 7 16 m to 7 16 m adapter 7 16 to 7 16 adapter 7 16 m to 7 16 f adapter two included C1 11906B 7 16 to Type N Includes Type N m
2. 00M substitutes module with 85092 60006 Type N m to Type N m RF ECal module Ol Option 00F substitutes module with 85092 60007 Type N f to Type N f RF ECal module Option 00A adds 85054 60037 Type N f to Type N f adapter 85054 60038 Type N m to Type N m adapter For devices with 3 5 mm or SMA connectors see Adapters section for information about the Agilent 11878A 3 5 mm adapter kit Mechanical calibration kits O 85033E economy 30 kHz to 9 GHz Includes 85033 60016 3 5 mm m load 85033 60017 3 5 mm f load 85033 60018 3 5 mm m open 85033 60019 3 5 mm f open 85033 60020 3 5 mm m short 85033 60021 3 5 mm f short 8710 1761 torque wrench O Option 100 adds 85027 60005 3 5 mm f to 3 5 mm f adapter O Option 200 adds 85027 60007 3 5 mm m to 3 5 mm m adapter O Option 300 adds 85027 60006 3 5 mm m to 3 5 mm f adapter O Option 400 adds 1250 1744 3 5 mm f to Type N 50 ohm m adapter 1250 1743 3 5 mm m to Type N 50 ohm m adapter 1250 1745 3 5 mm f to Type N 50 ohm f adapter 1250 1750 3 5 mm m to Type N 50 ohm f adapter O Option 500 adds 1250 1746 3 5 mm m to 7 mm adapter two included 1250 1747 3 5 mm f to 7 mm adapter two included O 85052C precision TRL 45 MHz to 26 5 GHz Includes 00902 60003 3 5 mm m fixed load 00902 60004 3 5 mm f fixed load 85052 60006 3 5 mm m short 85052 60007 3 5 mm f short 85052 60008 3 5 mm m open 85052 60009 3 5 mm f open
3. 5968 5329E 8 Hints for Making Better Network Analyzer Measurements Application Note 1291 1 literature number 5965 8166E Key Web Resources Visit our component manufacturer industry area at www agilent com find component_test Visit the PNA Series home page at www agilent com find pna Most application and product notes may be downloaded from our web site at www agilent com find tmappnotes apps Agilent Technologies Test and Measurement Support Services and Assistance Agilent Technologies aims to maximize the value you receive while minimizing your risk and problems We strive to ensure that you get the test and measurement capabilities you paid for and obtain the support you need Our extensive support resources and services can help you choose the right Agilent products for your applications and apply them successfully Every instrument and system we sell has a global warranty Support is available for at least five years beyond the production life of the product Two concepts underlay Agilent s overall support policy Our Promise and Your Advantage Our Promise Our Promise means your Agilent test and measurement equipment will meet its advertised performance and functionality When you are choosing new equipment we will help you with product information including realistic performance specifications and practical recommendations from experienced test engineers When you use Agilent equipment we can veri
4. 85052 60032 3 5 mm f to 3 5 mm f adapter 85052 60033 3 5 mm m to 3 5 mm m adapter 85052 60034 3 5 mm f to 3 5 mm m adapter 85052 60035 3 5 mm short TRL line 85052 60036 3 5 mm long TRL line O 85052D economy 45 MHz to 26 5 GHz Includes 00902 60003 3 5 mm m fixed load 00902 60004 3 5 mm f fixed load 85052 60006 3 5 mm m short 85052 60007 3 5 mm f short 85052 60008 3 5 mm m open 85052 60009 3 5 mm f open 85052 60012 3 5 mm f to 3 5 mm f adapter 85052 60013 3 5 mm f to 3 5 mm m adapter 85052 60014 3 5 mm m to 3 5 mm m adapter Electronic calibration kits O 85093B RF ECal 30 kHz to 9 GHz Includes 85093 60005 3 5 mm f to 3 5 mm m RF ECal module O Option 00M substitutes module with 85093 60006 3 5 mm m to 3 5 mm m RF ECal module O Option OOF substitutes module with 85093 60007 3 5 mm f to 3 5 mm f RF ECal module O Option 00A adds 85052 60012 3 5 mm f to 3 5 mm f adapter 85052 60014 3 5 mm m to 3 5 mm m adapter For devices with 7 mm connectors see Adapters section for information about Agilent 7 mm adapters Mechanical calibration kits O 85031B economy 30 kHz to 6 GHz Includes 00909 60008 7 mm coax termination 85031 60001 7 mm open short O 85050C precision TRL 45 MHz to 18 GHz Includes 00909 60008 7 mm coax termination 85050 60003 7 mm to 7 mm airline 85050 60005 7 mm to 7 mm TRL adapter 85050 60006 7 mm fixed broadband load 85050 80008 7 mm short 85050 80009 7
5. find mta Accessories are available in these connector types 50 ohm Type N 3 5 mm 7 mm and 7 16 Test port cables and a calibration kit should be added for a complete measurement system A verification kit is used to verify corrected system performance Test port cables Test port cables are used to connect the network analyzer to the device under test O N6314A 50 ohm Type N RF cable 300 kHz to 9 GHz Includes one 610 mm 24 in cable with male connectors part number 8120 8862 O N6315A 50 ohm Type N RF cable 300 kHz to 9 GHz Includes one 406 mm 16 in cable with one male and one female connector part number 8121 0027 O N3839A 50 ohm Type N RF cable 300 kHz to 9 GHz Includes one 406 mm 16 in cable with male connectors part number 8121 0101 Calibration kits Mechanical calibration kits include standards such as open short circuits and loads which are measured by the network analyzer for increased measurement accuracy Electronic calibration ECal kits replace mechanical calibra tion standards with one solid state calibration module that is controlled by the network analyzer to present many differ ent impedances to the test ports A full two port calibration can be performed quickly with a single connection This tech nique reduces errors and connector wear and abrasion Choose a calibration kit for each connector type to be used Economy includes e open standards male and female e short standards male
6. 0 kHz to 6 GHz O E8358A network analyzer 300 kHz to 9 GHz Options O Option 010 time domain capability For viewing reflection and transmission responses in time or distance domain O Option 015 configurable test set Adds front panel access to the source output and coupler input on both ports 1 and 2 35 dB step attenuators are also added between the couplers and receivers This capability provides the ability to improve measurement sensitivity for measuring low level signals or to add components and other peripheral instruments for a variety of measurement applications O Option 1CM rack mount kit Adds a rack mount part number 5063 9216 and rail kit E3663AC for use without handles O Option 1CP rack mount kit Adds a rack mount part number 5063 9236 and rail kit E3663AC for use with previously supplied handles O Option AM8 CD RW drive Adds an external read write CD drive with a USB cable O Option B30 USB hub Adds a 4 port USB hub for connecting additional USB peripherals Documentation O Option AVK adds printed copy of User s and Programmer s documentation part number E8356 90028 O Option OBW adds printed copy of assembly level service manual part number E8356 90002 Localization The following options provide a translated printed copy of User s documentation and an English printed copy of the Programmer s documentation Localized documentation will be available early 2001 O Option ABD Germa
7. 1 800 629 485 fax 61 3 9272 0749 New Zealand tel 0 800 738 378 fax 64 4 495 8950 Asia Pacific tel 852 3197 7777 fax 852 2506 9284 Product specifications and descriptions in this document subject to change without notice Copyright 2000 Agilent Technologies Printed in USA 09 2000 5980 1235E Agilent Technologies Innovating the HP Way
8. GHz power out 24 dBm to 20 GHz or 21 dBm to 26 5 GHz O 83020A power amplifier 2 to 26 5 GHz 30 dB gain to 20 GHz or 27 dB to 26 5 GHz power out 30 dBm to 20 GHz or 26 dBm to 26 5 GHz Couplers O 87300B coaxial coupler 1 to 20 GHz SMA f 10 dB coupling O 87300C coaxial coupler 1 to 26 5 GHz 3 5 mm f 10 dB coupling Equipment racks and case O 5063 9223 rack mount flange kit for use with handles includes handles O 5063 9216 rack mount kit for use without handles may be ordered as option 1CM O 5063 9236 rack mount kit for use with previously supplied handles may be ordered as option 1CP O E3663AC rail kit included with option 1CM and 1CP O 9211 2658 transit case Peripherals The following peripherals may be used with the E8356A E8357A and E8358A Other peripherals not listed here may also be compatible with these instruments CD ROM Drive O USB compatible CD ROM drive Monitors O VGA compatible monitor Printers O USB LAN parallel or serial printers with Microsoft Windows 2000 printer driver Interface cables Choose the appropriate cables to connect each peripheral to the network analyzer O 10833A GPIB cable 1 0 m 3 3 ft O 10833B GPIB cable 2 0 m 6 6 ft O 10833D GPIB cable 0 5 m 1 6 ft O HP C2950A Centronics parallel printer cable 2 0 m 6 6 ft Upgrade kits Upgrade kits for the E8356A E8357A E8358A Upgrade kits are available to add options aft
9. System Configuration Summary This summary lists the main components required to form a basic measurement system Options or peripherals may be added to provide enhanced measure ment and data storage capability Full S parameter measurements a Agilent PNA Series network analyzer Test port cables 50 ohms Calibration kit for applicable connector type Agilent RF Network Analyzers PNA Series Configuration Guide E8356A 300 kHz to 3 GHz E8357A 300 kHz to 6 GHz E8358A 300 kHz to 9 GHz ei een S E 6 m ql EEI C eig CL A This configuration guide describes standard configurations options accessories upgrade kits and compatible peripherals for the PNA Series of vector network analyzers This guide should be used with the Agilent PNA Series Technical Specifications for a complete description of these analyzers ifs Agilent Technologies fT Innovating the HP Way Agilent PNA Series Each PNA Series instrument is an integrated network analyzer with a built in LCD display hard and floppy disk drives S parameter test set and synthesized source The analyzer has two 50 ohm Type N f test ports Included with each instru ment is a mouse keyboard CD ROM containing a copy of the operating and programming manual set a mini parallel to paral lel adapter and a three year return to Agilent service warranty O E8356A network analyzer 300 kHz to 3 GHz O E8357A network analyzer 30
10. and female e fixed termination standards male and female e in series adapters Standard includes the devices in the economy kit and adds e connector tools Precision includes the devices in the economy kit and adds e 50 ohm airline for TRL calibration e TRL adapters e connector tools For devices with Type N connectors Mechanical calibration kits O 85032F economy 30 kHz to 9 GHz Includes 85032 60017 Type N m fixed load 85032 60018 Type N f fixed load 85032 60013 Type N m open 85032 60014 Type N f open 85032 60016 Type N m short 85032 60015 Type N f short CO Option 100 adds 85032 60021 Type N f to Type N f adapter O Option 200 adds 85032 60019 Type N m to Type N m adapter Ol Option 300 adds 85032 60020 Type N m to Type N f adapter O Option 500 adds 85054 60001 Type N f to 7 mm adapter two included 85054 60009 Type N m to 7 mm adapter two included O 85054D economy 45 MHz to 18 GHz Includes 85054 60025 Type N m short 85054 60026 Type N f short 85054 60027 Type N m open 85054 60028 Type N f open 85054 60031 Type N f to 7 mm adapter 85054 60032 Type N m to 7 mm adapter 85054 60037 Type N f to Type N f adapter 85054 60038 Type N m to Type N m adapter 85054 60046 Type N m fixed load 85054 60047 Type N f fixed load Electronic calibration kits O 85092B RF ECal 30 kHz to 9 GHz Includes 85092 60005 Type N f to Type N m RF ECal module C Option
11. er initial purchase To order an upgrade kit for an E8356A E8357A E8358A order the analyzer s model number followed by a U then indicate the option to be added O Option 010 time domain upgrade kit part number E8356 60101 The serial number of the E8356A E8357A or E8358A to be retrofitted must be specified when ordering this kit Installation is not included O Option 015 configurable test set upgrade kit part number E8356 60102 Includes installation at an Agilent service center O Option AM8 CD RW drive Includes an external read write CD drive with a USB cable O Option B30 USB hub Includes a 4 port USB hub for connecting additional USB peripherals O Option 099 firmware upgrade part number E8356 60103 Provides the latest revision of firmware for the PNA Series on CD ROM Firmware is user installable Installation requires USB CD ROM drive or external computer connected via LAN The latest firmware is also available from our web site Visit our web page at www agilent com find pna Upgrades requiring model number changes are addressed on a special handling quotation basis Contact your local Agilent sales or service office for further information Literature and information PNA Series Brochure 5968 8472E PNA Series Technical Specifications 5980 1236E Application and product notes Literature number Application Development with the Agilent PNA Series of Network Analyzers literature number 5980 2666ENUS Understandi
12. fy that it works properly help with product operation and provide basic mea surement assistance for the use of specified capabilities at no extra cost upon request Many self help tools are available Your Advantage Your Advantage means that Agilent offers a wide range of addi tional expert test and measurement services which you can purchase according to your unique technical and business needs Solve problems efficiently and gain a competitive edge by con tacting us for calibration extra cost upgrades out of warranty repairs and on site education and training as well as design system integration project management and other professional services Experienced Agilent engineers and technicians world wide can help you maximize your productivity optimize the return on investment of your Agilent instruments and systems and obtain dependable measurement accuracy for the life of those products Microsft and Windows are U S registered trademarks of Microsoft Corporation For more assistance with your test and measurement needs go to www agilent com find assist Or contact the test and measurement experts at Agilent Technologies During normal business hours United States tel 1 800 452 4844 Canada tel 1 877 894 4414 fax 905 206 4120 Europe tel 31 20 547 2000 Japan tel 81 426 56 7832 fax 81 426 56 7840 Latin America tel 305 267 4245 fax 305 267 4286 Australia tel
13. mm short collet 85050 80010 7 mm open O 85050D economy 45 MHz to 18 GHz Includes 85050 60006 7 mm fixed broadband load 85050 80007 7 mm short 85050 80010 7 mm open Electronic calibration kits O 85091B RF ECal 30 kHz to 9 GHz Includes 85091 60003 7 mm to 7 mm RF ECal module For devices with 7 16 connectors see Adapters section for information about the Agilent 11906B 7 16 to Type N adapter kit Mechanical calibration kits O 85038A standard 30 kHz to 7 5 GHz Includes 85038 80002 7 16 f open 85038 80003 7 16 m open 85038 80004 7 16 f short 85038 80005 7 16 m short 85038 80006 7 16 f fixed load 85038 80007 7 16 m fixed load 8710 2175 torque wrench 8710 2174 open end wrench O 85038F economy 30 kHz to 7 5 GHz Includes 85038 80002 7 16 f open 85038 80004 7 16 f short 85038 80006 7 16 f fixed load 11906 80016 7 16 f to 7 16 f adapter O 85038M economy 30 kHz to 7 5 GHz Includes 85038 80003 7 16 m open 85038 80005 7 16 m short 85038 80007 7 16 m fixed load 11906 80015 7 16 m to 7 16 m adapter Electronic calibration kits O 85098B RF ECal 30 kHz to 7 5 GHz Includes 85098 60005 7 16 m to 7 16 f RF ECal module Ol Option 00F substitutes module with 85098 60007 7 16 f to 7 16 f RF ECal module Ol Option 00M substitutes module with 85098 60006 7 16 m to 7 16 m RF ECal module Ol Option 00A adds 11906 80015 7 16 m to 7 16 m adapter 11906 80016 7 16 f to 7 16 f adapter
14. n manual part number E8356 90032 O Option ABE Spanish manual part number E8356 90031 O Option ABF French manual part number E8356 90029 O Option ABJ Japanese manual part number E8356 90030 Certification options O Option UK6 Commercial calibration certificate with test data Service and support options O Option WO1 Converts three year return to Agilent service warranty to one year on site service check with your local Agilent sales or service office for availability in your area O Option W31 Converts three year return to Agilent service warranty to three year on site service check with your local Agilent sales or service office for availability in your area O Option W32 Three year return to Agilent commercial calibration agreement O Option W34 Three year return to Agilent standards compliant calibration agreement O Option W50 Extends return to Agilent service warranty to 5 years O Option W51 Converts three year return to Agilent service warranty to five year on site service check with your local Agilent sales or service office for availability in your area O Option W52 Five year return to Agilent commercial calibration agreement O Option W54 Five year return to Agilent standards compliant calibration agreement Measurement accessories A complete line of RF test accessories can be found in the Agilent RF and Microwave Test Accessories Catalog literature number 5968 4314EN or by visiting www agilent com
15. ng and Improving Network Analyzer Dynamic Range Application Note 1363 1 literature number 5980 2778EN The Need for Speed in Component Manufacturing Test literature number 5980 2783EN Generate Component Data Sheets with Agilent s BenchLinkXL literature number 5980 2781EN Connectivity Advances in a LAN enabled Instrument literature number 5980 2782EN De embedding and Embedding S parameter Networks Using the PNA Series Network Analyzer Application Note 1364 1 literature number 5980 2784EN Advanced Filter Tuning Using Time Domain Application Note 1287 10 literature number 5980 2785EN Understanding the Fundamental Principles of Vector Network Analysis Application Note 1287 1 literature number 5965 7707E Exploring the Architectures of Network Analyzers Application Note 1287 2 literature number 5965 7708E Applying Error Correction to Network Analyzer Measurements Application Note 1287 3 literature number 5965 7709E Network Analyzer Measurements Filter and Amplifier Examples Application Note 1287 4 literature number 5965 7710E Improving Throughput in Network Analyzer Applications Application Note 1287 5 literature number 5966 3317E Using a Network Analyzer to Characterize High Power Components Application Note 1287 6 literature number 5966 3319E Simplified Filter Tuning Using Time Domain Analysis Application Note 1287 8 literature number 5968 5328E In Fixture Measurements Using Vector Network Analyzers Application Note 1287 9 literature number
16. to 7 16 m adapter Type N to 7 16 adapter Type N f to 7 16 m adapter Type N m to 7 16 f adapter O 11854A 50 ohm BNC accessory kit Includes 1250 0929 BNC m short 1250 1473 BNC m to Type N m adapter two included 1250 1474 BNC f to Type N f adapter two included 1250 1476 BNC to Type N m adapter two included 1250 1477 BNC m to Type N f adapter two included General accessories Probe O 85024A high frequency probe Provides high impedance in circuit test capability from 300 kHz to 3 GHz Power meters and sensors Recommended for self support adjustments and performance tests to verify proper instrument operation O E4418B single channel power meter O E4419B dual channel power meter O 8482A power sensor 100 kHz to 4 2 GHz Type N m 100 mW O E4412A CW power sensor 10 MHz to 18 GHz Type N m 200 mW 1 RF connectors 3 5 mm f on RF input and output BNC f detector out Type N f on RF input and output for 8347A 2 A PNA Series analyzer is supplied with handles Amplifiers O 8347A RF power amplifier 100 kHz to 3 GHz 25 dB gain power out 20 dBm O 83006A power amplifier 10 MHz to 26 5 GHz 20 dB gain power out 18dBm to 10 GHz or 16 dBm to 20 GHz or 14 dBm to 26 5 GHz O 83017A power amplifier 50 MHz to 26 5 GHz 25 dB gain power out 20 dBm to 20 GHz or 15 dBm to 26 5 GHz O 83018A power amplifier 2 to 26 5 GHz 27 dB gain to 20 GHz or 23 dB to 26 5
Download Pdf Manuals
Related Search
Related Contents
取扱説明書 Fujitsu ESPRIMO P2540 Valueline VGVP34100B100 User Manual of AQ-ZSAi 30A 2~Bs Electronic - au owner`s manual manuel de l`utilisateur manual del propietario GoTalk 20+ User's Guide Peavey SP 112M User's Manual GC-1021D - Fiberglass Choppers, Operation, English qui - PLC Forum info fisher-price.com Copyright © All rights reserved.