1. MACHINED SURFACE AROUND INSIDE HOLE FACES AWAY FROM GLASS RIM POSITION ADJUSTMENT THIN PLASTIC WASHER GOES UNDER RING NUT SOLID PLATE GI aa n TAE N _ a N ni f b W g t 2 pi RI V e VE SENSOR vsi ADJUST SIGNAL LEVEL TO BE 9 1 2 10 wm GREEN LED OVERLAP K Sg DELAY 1000 P aes ser g lee san X CAN ATIC LOOSEN ZA KNOBS TO ROTATE NOZZLE TUBE L lt kadi zi Rad k AE 7 LOAD PILL COUNT HERE SECTION 4 RIM GUIDES DESCRIPTION AND SET UP 4 1The TC machine counts pills capsules etc when they fall from the edge of the glass turntable through a beam of light projected from a red light emitting diode LED light source to a photoelectric sensor The TC scanner actually detects the shadows of a product passing through the red LED light beam Product must drop through this beam to be counted The accuracy of the TC depends a great deal on proper adjustment of the product guides They are designed to accurately deliver a flow of product to the counting sensor area with little deviation from an ideal flow axis Piggyback product and jam ups in the guides must be prevented Certain guides are intended for certain type products Guides can be modified to accommodate unusual Shapes and sizes 4 2 Guide Support Block Assembly Centerpiece of the guide system The main feature of this assembly is that once it is lined up with the
2. before making the adjustment 44 P OOOOOOO j LOJ Back Side Adjustments 3 Diverter Flag Delay Test This is the setup procedure TC power on and motor and vibrator feed off Put 7 pills end to end in the guide channel and set the speed at 5 Set a count of 4 in the DC3 counter preset register and push reset Put bottles 1and 2 under each fill station When you turn on the motor switch the TC will deliver 7 pills through the scanner The diverter will separate these pills into 4 in bottle 1and then switch the flow to bottle 2 where it delivers the last 3 pills If you get 3 in bottle 1 you need more delay If you get 5 in bottle 1 you have too much delay The time delay set TDS trim pot adjustment is located next to the scanner adjustment trim pot inside the IC Perform this test at least 10 times You should get the same results every time If you discover it fills correctly when the diverter flag begins with the left side and changes to the right but has an error when beginning with the right side and changes to the left you have a diverter flag that binds in one direction Call for advice 4 Count Signal Threshold Adjustment Test TC power on Adjust the scanner signal lever with black knob located below the bargraph display As the level drops below 5 to 4 the red LED to the side of the bargraph will turn off It turns on again when you raise the level back to 5 This shows the level at which the threshold is set If the threshold m
3. through which it passes is clean If the flag movement is not free call for assistance 7 Check for loose hardware in these areas a Hopper door assembly b Vibrator feed pan two sieve hold down screws c Rim guide channel assemblies d Rim inner hub lower band assembly e Rim hub mounted deflector assembly spring and hardware f Diverter ahead assembly deflector flag funnel assembly 8 Be sureall door panels are tight before using the machine If not the vibrating action of the feed pan will be compromised 9 When cleaning the DC3 electronic counter panel do not allow liguid to drip into the switch assembly It will damage the switch elements Be sure the switch buttons will move the digits easily without binding 10 There are no parts on the machine that require lubrication Turn on the machine prior to actual production and listen carefully for unusual noises while the motor and vibrator are set at half their range of adjustment This can be the best indication of something that is not right Listen for loose hardware and or guides that rattle glass rubbing against the rim or against the guides Look for smooth movement of the glass plate The rim should not rise and fall as the glass turns rubbing Recommended optional or replacement parts 1 Hopper Extension doubles capacity of the hopper 2 Glass Plate 20 if the plate breaks during handling you can not operate 3 AS1 Filters must be replaced when the fi
4. hot water in a sink Larger items that are not easily removed can be wiped clean with a cloth dampened with cleaning disinfecting solution c Use a cleaning disinfecting product that has been determined to be most suitable for your application A 50 50 water alcohol solution is commonly used d Use clean compressed air to speed the drying process Otherwise dry with a cloth or paper towels 8 2 Cleaning contact surfaces for product changeover This procedure covers surfaces that have contact with the product Refer tot he attached drawing IC2 R and L are similar Disassemble the machine as shown but do not remove legs or bottle shelf They are not shown for clarity a Hopper remove hopper door to clean door and surface under the door Wipe down all surfaces of the hopper b Vibrator feed tray and sieves remove and wash sieve Feed tray can be removed if desired or may be wiped down as installed c Dust cup wash in sink d Rim assembly although it can be removed and washed in a sink it is usually subjected to a thorough wipe down Guides are removed and washed Air guide nozzle is removed and washed e Glass plate wash thoroughly The aluminum support ring should not be removed if glued to the glass plate Wash the plastic washer and ring nut f Scanner do not wash the scanner in the sink Wipe down surfaces Prevent fluid from entering the scanner body g Diverter head remove and wash the sheet metal outer cover inn
5. inch high Use it for capsules caplets and gel caps Do not use the height guide with this guide As capsules align with the opening on the capsule guide the piggyback condition corrects itself as the top capsule rolls off the lower capsule and falls outside the low profile edge of the capsule guide Should this not be the case then the piggybacked capsule will run into the capsule kick out wire which will eject the top capsule at the opposite end of the channel The capsule guide attaches to the same type guide support arm as the tablet guide This guide is used at all times with the AGS option See photo below 4 7 Capsule Kick out Wire Guide A stainless steel wire bent to achieve a desired effect When adjusted correctly the rectangular end is so that the top capsule of a piggybacked pair is diverted out of the guide channel This guide must be mounted so that it retains its springiness and will not create a blockage When a capsule hits the wire bounces and ejects the capsule Not for use with AGS option See photo below 4 8 Deflector Guide Spring loaded curved blade that is attached to the rim center hub It pushes the product toward the perimeter of the rim Because it is spring loaded it gives under a load The spot where it attaches to the hub is the only adjustment You can increase or decrease the force that is applied to the product flow by moving the diverter spring to a tighter hole position Bend the blade to suit your condit
6. processing equipment Stainless Steel Shafting Type 303 desired for machineability Properties similar to Type 304 Polycarbonate Thermoplastic Tubing FDA compliant Glass plate Lime glass FDA Compliant SECTION 8A SUGGESTED SPARE PARTS FOR PHARMAFILL MACHINES TCA2 Tablet Counter P2503 20 diameter glass plate 165 00 P0118 AS i air filters 17 00 FM2199 Glass protection plastic ring 2 00 EMA2515 2R Capsule guide for TC2R 33 00 FM2540 1 Scanner LED cover all clear 5 00 FM2540 100 Scanner photocell cover masked 10 00 AD1085 Full set of TC and ABF2 fuses 10 total 20 00 Explanation The glass plate will break if dropped during cleaning The AS1 filters will become too dirty to clean The glass protection ring seems to get lost easily It protects the glass plate from the ring nut The capsule guide has a somewhat delicate weld that can snap if handled roughly The scanner cell and LED covers are wiped clean frequently and will eventually scratch and need replacement Fuses will blow out for various reasons ABF2 AClauto index control CV4 5 conveyor P0142 Electric air valve Mead part of AC1and CS1 61 00 FM3067F Air cylinder bottle stop Norgren modified 53 00 P1107 4 5 Wide tablet top chain links conveyor 17 00 ft P5816 Relay MK2PS24vdc part of AC1 and CS1 17 00 P1184 Conveyor rail splice links 5 00 Explanation The air valve will malfunction if there is dirt and moisture in the compress
7. warranty provided by the manufacturer of non Pharmafill machinery electric motors and clutch assemblies supersedes the Pharmafill warranty In most cases the other warranty periods are one year All warranties require that the faulty component subassembly or complete machine is returned promptly to Deitz Co freight prepaid Warranty replacement parts are shipped by next day express service without charge to the customer Deitz Co is not obligated by this warranty to reimburse a customer for any loss greater than the original price of the purchased Pharmafill machinery A complete machine must be returned to Deitz Co with prior approval to obtain reimbursement A return reimbursement request must be made within 30 days after delivery of the equipment Freight charges shipping to and from the customer are the responsibility of the customer and are not reimbursed Warranty terms are suspended if the purchase and payment terms are not current or are not as described in the sales invoice rendered by Deitz Co to the customer A suspended warranty will be reinstated when payment or sale terms are complied with Payment can not be withheld or postponed without advance approval by Deitz Co Customers Name amp Address Model and Serial No s Sample sample sample sample Customer should sign copy of this document and return to Deitz Co Inc
8. while the delay is in effect will be ignored 6B 4 Overlap Time Delay Adjustment Located below the green LED Fully CCW is minimal delay Keep the adjustment CCW for all opaque products The green LED should not flash For clear gel caps turn the adjustment CCW for all opaque products The green LED should not flash For clear gel caps turn the adjustment CW until the green light begins to flash as gel caps are passing through the scanner beam This should be the proper setting for whatever length gel cap you are counting The adjustment numbers are for reference and mean nothing otherwise Check bottle guantity before beginning production and make small adjustment changes based on test bottle count check Generally speaking under filled bottles mean the delay is too short Over filled bottles mean the delay is too long Back Side Adjustments SCAN ADJ TPS TDS Open the main control door to get access to these adjustments 6B 5 Time Delay Set TDS The diverter flag directs the flow of counted product from one fill station to the other shortly after the electronic counter registers the preset count value The count signal is created by the scanner which is about 3 4 above the diverter flag range of travel The diverter changes fill stations after a slight delay in order to compensate for the distance from the scanner to the diverter flag Delay time is changed by adjusting the TDS trim pot Normally delay is minimal and the adjustme
9. AS1 filters should be checked regularly See photo Section 2 8 IMPORTANT NOTE DEITZ CO DOES NOT GUARANTY THAT THE USE OF THE AS1 BLOWER WILL NOT CAUSE CONTAMINATION OF PRODUCT TO THE BEST OF OUR KNOWLEDGE AND RESEARCH WE HAVE CONCLUDED THAT THERE IS NO MORE RISK BY USING THE AS1 WITH BOTH FILTERS THAN OCCURS WITH ANY PRODUCT EXPOSED TO ROOM AIR 5 4 Air Guide Adjustments The nozzles must be as close to the slotted guide as possible and they should be low enough to blow away the top tablet or capsule when a piggybacked pair passes A nozzle is too low if it causes the line of tablets to lift and dance as they pass the nozzle 5 5 Keeping Blockages from Happening Most blockages are caused by odd shaped or rough caplets The guide channel opening gets randomly hit by misaligned caplets If a caplet hits the point of the AGS inner guide it will not climb up on the guide as we would like Adjust the guide by loosening two screws in the support bracket Adjust so the point at the leading edge is close to the glass The misaligned caplet will climb up on the capsule guide which will put it in the air stream of nozzle 1 and it will be blown clear of the guide channel See Section 3 photo 14 5 6 Do not use the height guide with the AGS inner guide because the AGS guide will interfere You can use the capsule wire guide if heavy product is not moved by the air flow The air will provide a force to push heavy product once the wire begins the pr
10. PHARMAFSLL DEITZ COMPANY WALL NJ USA Models TCI TC2 and ICA2 Tablet Counter Operations and Service Manual TABLE OF CONTENIS 1 GENERAL DESCRIPTION OF PHARMAFILL TABLET COUNTERS 2 MAJ OR COMPONENTS OF THE TC 3 HOW TO PUT THE IC IN SERVICE 4 RIM GUIDES DESCRIPTION AND SET UP 4A RIM GUIDES ADJ USTMENT PROCEDURES amp COUNT ACCURACY TIPS 4B RIM LOCATION ADJ USTMENT INSTRUCTIONS 5 THE AIR GUIDE ASSEMBLY AGS OPTION 6 EXTERNAL ELECTRONICS SET UP AND ADJ USTMENT GA AD0956 SCANNER INSTALLATION AND OPERATION 6B SCANNER SIGNAL DISPLAY PANEL 7 AUTOMATIC VIBRATOR FEED CONTROL AFC OPERATION 8 PHARMAFILL CLEANING PROCEDURE amp CONSTRUCTION MATERIALS 8A SUGGESTED SPARE PARTS FOR PHARMAFILL MACHINES 8B TCAZR AS1 MAINTENANCE REQUIREMENTS 9 TABLET COUNTER ADJ USTMENTS FOR ACCURACY 10 DRAWINGS PHARMAFILL TWO YEAR LIMITED WARRANTY FOR NEW MACHINES SECTION 1 GENERAL DESCRIPTION OF THE PHARMAFILL TABLET COUNTER Pharmafill tablet counters are usually described as electronic tablet counters They can be used to count tablets capsules caplets gel caps hard and soft and most common solid oral dose type products They are also used to count cosmetic gel caps and other products with a shape Similar to a tablet or capsule The word tablet as used in the operating manual will include capsules gel caps etc There are two distinct models The TC1 is the smaller of the two It has a 16 diame
11. You must use the guides that are appropriate for the size TC1 TC2 machine and the configuration R L The following guides are part of the guide adjustment block assembly tablet guide capsule guide height guide kick out wire guide In addition there is a flow corrector guide and the optional air guides may be part of the machine The guides make the guide channel through which the tablets move single file to the edge of the turntable Look for more information about the guides in section 4 2 3C Spring Loaded Deflector Guide Attached to the side of the center hub It pushes the tablets toward the inside edge of the rim band inline with the opening of the guide channel Spring tension can be adjusted by moving the tip of the coil spring into a different hole in the deflector guide The half round metal target for the automatic vibrator feed sensor mounts on top of the deflector guide shaft See photo below 2 3D Air Guide Nozzle Assembly This optional assembly attaches under the guide block Look for information in the Air Guide System AGS section See photo below 2 3E Rim Cover Deitz Co provides a clear poly carbonate cover for the rim The cover has a 3 diameter round tube to which vacuum can be attached The cover is held in place by the same knob that holds the rim in place Guide Block SECITON 2 4 GLASS PLATE ASSEMBLY 2 4A Glass Plate A nominal 25 thick and either 16 or 20 in diameter Glass is used because it will rem
12. ae deliver AC power to the entire tablet counting machine and also specifically to the turntable motor and feed vibrator The PC3 connects by two cable connectors to the AD0995 Interconnection Board Fuses that protect the PC3 circuits are normally located on the Interconnection Board Main Power Switch A lighted rocker type switch Switches power to the entire machine through the Interconnection Board Motor Turntable Switch A lighted rocker switch that turns on power to the turntable motor circuit Turntable speed depends on the adjustment of the motor speed control knob The motor switch delivers power to the feed vibrator switch Feed Vibrator Switch A lighted rocker switch that turns on power to the feed vibrator circuit if the motor switch is also on Feed rate depends on adjustment of the feed control knob and a signal from the automatic vibrator feed control sensor Exceptions There are several different versions of the PC3 in use This information is current Older TC machines may have a PC3 that looks the same but is wired differently Older PC3s have fuses located on the back panel 2 1B DC3 Electronic Counter ADO770 2 A blue panel located beside the PC3 The DC3 displays how many tablets are counted in large red numbers upto 9999 _ am DEITZ COUNTER DC3 Preset Count Register A mechanical count register located below the display can be preset with a number at which the DC3 will reset Push th
13. ain flat under all conditions and does not react with most chemicals The center hole is precisely located and drilled It is not easy to duplicate See Section 3 photo 1 2 4B Aluminum Ring Supports the glass Itis machined to fit level on the glass support hub A slot in the ring must line up with a pin located in the side of the glass support hub See Section 3 photo 1 2 4C Glass Protecting Washer Placed on top of the glass before the ring nut is tightened This protects the glass from abrasion by the ring nut See Section 3 photo 2 2 4D Ring Nut Large threaded ring with a knurled edge It tightens the glass on the glass support hub Hand tighten Do not use a tool on this ring nut See Section 3 photo 2 SECTION 2 5 VIBRATOR FEED ASSEMBLY 2 5A Vibrator Inside the machine under the hopper area It shakes the feed tray and causes the tablets to spread out and move toward the rim The rate of vibration is controlled by the knob on the PC3 The automatic vibrator feed control circuit will also turn the vibrator on and ofi depending on a signal from the automatic vibrator feed control sensor The vibrator will not operate if either the feed or the motor switch is off 2 0B Feed Tray Mounts on top of the vibrator Be sure the hopper is not touching the tray during operation See Section 3 photo 7 2 5C Sieve Plate Fits in the base of the tray Dust and broken pills fall through the holes in the plate to the bottom of the tray The debris f
14. alls through a slot in the tray into a dust cup located under the feed tray There are three sieve plates each with different size holes A solid panel has no holes See Section 3 photo 8 2 5D Dust Cup Under feed tray Accumulates dust and debris that falls through sieve plates into feed tray and through slot in bottom of feed tray See Section 3 photo 9 SECITON 2 6 HOPPER ASSEMBLY 2 6A Hopper Nested around the feed tray It isnot attached to the machine Open the hopper door to allow a product flow that is equal to the count rate Do not overload the tray 2 6B Hopper Extension Nests on top of the _ It roughly doubles the capacity of the 2 7A Interconnection Board AD0995 Accessible from the rear of the machine It is the connection point for 115 vac line power the PC3 vibrator and the power supply It has four fuses for main power external outlet motor and vibrator circuits 2 7B Power Supply AD0986 Reduces 115 vac to low voltages required for the control circuits Three LED indicators red yellow and green show the status of certain voltages and signals A metal heat sink on this board is normally hot 2 7C Signal Processor Board AD0984 Coordinates inputs and outputs for most of the machine operations This board is attached to the scanner signal display panel by a flat ribbon cable and can not be disconnected from it Three test switches should not be touched The test switch handles norma
15. aps Blow debris off the circuit boards 3 Check the scanner LED and photocell covers The LED cover is clear The photocell cover has a clear middle slot surrounded by a black mask Clean the outside surface If you see dust under the cover remove the cover and clean the underside as well If you see dust on the LED or photocell use a fine brush to dust off the elements or use compressed air to blow off the dust It should never be necessary to take the scanner apart It is not recommended Dust on the covers reduces the scanner signal level as displayed on the scanner signal display panel 4 Check glass plate for scratches nicks and chips If there is evidence of a chip and the glass is still usable use a hand held fine grit grinding stone to soften the edges of the chip This will show that the chip has been identified and treated and is not anewchip Scratches occur when the guides are adjusted too low and they scratch the glass Adjust the guides so they do not touch the glass 5 Check the motor and glass support hub sprockets for integrity and proper belt tension When the motor is off you should not be able to rotate the glass plate with fingertip pressure If you can the motor sprocket is loose 6 Check the diverter flag movement and it s linkage located behind the diverter head assembly inside the machine The flag should move freely If it is binding it will effect count accuracy Be sure the flag shaft is not bent and the bushing
16. block the light and may not be counted Tablet trajectory can be adjusted so that the flow is through the scanner centerline by turning the entire rim assembly CW or CCW See 4B 4 Rim Locating 4B 1 Scanner Centerline 2 small dots are machined into the top surface of the scanner end blocks Each dot is centered over either the LED or the photocell The scanner beam axis is in line with the dots Tablets should fall between the dots See Section 3 photo 12 4B 2 Diverter Flag Centerline Factory adjusted always lined up with the scanner centerline 4B 3 Scanner Signal Display Panel SS Part of the front control door A 10 segment bar graph display provides a visual indication of the scanner s photocell signal strength An adjustment knob makes signal level adjustment possible As product drops through the scanner beam the photocell signal momentarily decreases Rim adjustments that achieve an ideal tablet trajectory through the scanner centerline are indicated on the SS display as the greatest decrease in signal Older machines that do not have the SS panel on the control door have this display on circuit board 43 inside the control door 4B 4 Rim Locating Techniques In order to be sure the rim is always installed on the TC machine in the same position a sheet metal fork shaped fabrication is fastened to the rim A pin is mounted in the machine top cover As the rim is placed in position the fork always straddles the pin to correctly al
17. centerline of the diverter flag and the scanner sensor LED axis it maintains the centerline position regardless of changes to the width of the guide opening Four slots hold guides in position never four at a time All guides should fit tightly in the slot with little side to side movement See Section 3 photo 10 4 3 Outer Flow Guide Attached to a short guide support arm It is one side of the guide channel A flexible stainless steel tab attached to the rim must be located to the inside of this guide to conform to the bend in the rim at the entrance to the guide channel As product circles on the glass turntable it moves to the perimeter and the outer flow guide directs it into the guide channel It is slotted for use with the AGS option See photo below 4 4 Tablet Guide Attaches to a long guide support arm It is a rectangular blade with a sharp vertical edge at the front It is used with tablets only and is always used with the height guide It separates the flow of product on the glass turntable into a single line of tablets that pass down the channel See photo below 4 5 Height Guide White plastic wedge that attaches to an adjustment bracket by a rod Its function is to knock off the top tablet of piggybacked pairs as they attempt to enter the guide channel Use with tablets only See photo below 4 6 Capsule Guide Attaches to a long guide support arm For use instead of the tablet guide It has a long narrow pointed end and is 1 8th
18. e 9 pills pass through the scanner into the bottles You should have 5 pills in the first bottle and 4 in the second If there are 4 in the first bottle the diverter needs more delay If there are 6 in the first bottle the diverter has too much delay You can change the number of pills used but never count fewer than half the number available because the diverter can not move two times in so short a time SECTION 7 AUTOMATIC VIBRATOR FEED CONTROL AFC OPERATION Automatic Vibrator Feed Control turns the tablet feed vibrator on or off depending on the load of tablets on the turntable AFC is a standard feature on new Pharmafill TC2s and an option on TC1 and older machines Tablet counters without this feature delivered product to the turntable at whatever rate was selected The glass turntable could be underfed or overloaded depending on how fast the product moved down the guide channel and was counted AFC changes the feed function to deliver product as needed Components of the AFC 7 1 Deflector Guide The deflector guide is a spring loaded 8 long blade that is attached to the center hub of the turntable rim Its original purpose was to push product toward the outer edge of the turntable in line with the opening of the guide channel When a heavy load of product hits the deflector blade it pushes the blade in toward the center hub Spring tension is adjustable Tension should reliably push a light load of pills toward the turntable edge and sho
19. e scanner signal is produced by the photocell It reacts to the light from the LED which is carefully aimed at the photocell If the LED is touched too hard it can be misaligned and may not be aimed at the photocell correctly When the light from the LED is detected by the photocell there is a strong signal When a falling pill blocks the light the signal drops significantly and a count occurs The intensity of the LED is controlled by a trim pot adjustment inside the TC 3 The electronic circuits that amplify and process the photocell signal are adjusted so whenever the signal drops below a certain threshold trigger point a single count is generated The signal signal must return to a level above the threshold before another pill passes the scanner In other words the scanner must see a clear space between the pills falling through the scanner gap Photocell signal amplification is controlled by the black knob located under the level bargraph display on the front control door The threshold is adjusted by a trim pot adjustment inside the TC 4 The photocell and the LED mounting blocks have a plastic cover The LED side has a clear plastic cover The photocell side has a masked cover which is mostly black with a clear strip in the middle Covers are intended to keep dust off the LED and photocell Dust reduces the light from the LED and will cause low signal problems Clean the outside of the cover when dust accumulates It may al
20. e sguare buttons above or below the register window to change the preset number Count Reset When the DC3 resets the diverter head changes filling stations A push button manually resets the counter and 0000 is displayed Exceptions The DC3 normally displays 0000 when power is applied If anumber such as 2222 is displayed and can not be reset by the reset push button it is an electronic guirk Change the number to 2223 by passing your finger through the scanner beam and then push the reset button 2 1C Bottle Counter This is a small counter module located at the hopper end of the control door panel It is a self contained battery operated device that counts the number of times the DC3 counter resets A reset button below the display will reset the displayed count to zero The counter can be used to show how many bottles have been filled during a production run The battery can not replaced When it fails the entire counter module must be replaced 2 1D Scanner Signal Display Panel AD0985 A 10 segment bar graph display shows the scanner signal level It reacts guickly as pills pass through the scanner beam Using the knob located below the display set the signal to 9 10 level for normal operations The red LED indicator to the left of the display is lit when the signal processing circuit is ready to count If this LED is not lit the TC can not count and some corrective actions are probably necessary Clear Gel Cap Center Overlap Thi
21. ection will itemize and explain in detail the major considerations 4A 1Channel Width Especially important It should be as narrow as possible and yet present no resistance to product flow The product should not bounce from side to side within the channel This causes an uncertain drop trajectory from the edge of the glass depending on which side of the channel was last hit 4A 2 Outer Flow Tablet and Capsule Guides Can be adjusted for their height over the glass They should be no more than half the thickness of the product counted The guides should not scrape on the glass or they will scratch it The capsule guide tip must be as close to the glass as possible so that the point does not hold capsules or caplets at the opening of the channel 4A 3 Height Guide Used with the tablet guide only It should be adjusted slightly higher than the tablet height When piggybacked tablets attempt to enter the channel this guide will knock off the top tablet The height guide will jam up with capsules and especially caplets and soft gel caps 4A 4 Kick out Wire Guide Normally used with capsules caplets and soft gel caps but it can be helpful for tablets as well if the capsule guide is being used It is used with the capsule guide unless the AGS option is used You must adjust this guide so that the rectangular paddle at the end will nudge the top capsule of a piggybacked pair out of the guide cutout opening Do not let the wire make contact with the
22. ed air Same applies to the bottle indexing air cylinders The conveyor chain links can break The relay contacts will eventually pit from use and require replacement If you custom cut the conveyor guide rail you may need the slice links indicates part is also used in other machines March 2005 SECTION 8B TCA2R AS1 MAINTENANCE REQUIREMENTS 8B 1The TCA2 should be cleaned according to your cleaning protocol prior to use Use cleaning solution or diluted alcohol and water to wipe down all surfaces that have product contact 8B 2 End of day Maintenance 1 Remove the AS1 input and output filters a Clean input filter by tapping the filter on a table top or use compressed air to blow dust out of the filter element folds Input filter can be reused until it 1 noticeably restricts air flow 2 allows dust to pass through because it has a hole b Check output filter for dust It should be clean If not dust must be passing through a hole in the input filter Another source of dust on the output filter is potentially from a disintegrating AS1 impeller If it is determined that the impeller is wearing out you must stop using the AS1 To date 3 30 05 an impeller has never failed c Never swap the two filters Opposite sides are contaminated d Restricted air flow will make the output air warmer than usual 2 Open the front and rear doors Remove blow out accumulated product debris that falls into the machine through the door closure g
23. ensor Be sure the target is directly in front of the sensor after the rim cover is installed The sensor bracket is mounted on top of the rim cover 7 7 The yellow indicator light at the rear of the sensor should be off When the deflector blade tip is moved about 2 inches in toward the center hub the sensor light should go on If the vibrator power is on you will see that the vibrator turns off when the sensor light is on Notes The deflector guide must move freely and not drag against the glass Adjust the deflector bracket at the center hub as required Tf the vibrator will not turn on be sure the AFC sensor is not turning it off Refer to drawings of the deflector adjustments located at the end of this manual SECTION 8 PHARMAFILL ICA2 ABF2 DABF2 ASTY AGS CLEANING PROCEDURE AND CONSTRUCTION MATERIALS 8 1 Cleaning procedure for Pharmafill Tablet Counters The method used to clean the tablet counter must be based on the cleaning protocols that prevail at your establishment Cleaning may not remove all traces of product A machine used to count certain pharmaceutical products ie penicillin that can cause a serious allergic reaction in a patient should be dedicated to only that product to prevent cross contamination The following information is only suggested and may not be suitable for your operation a Disconnect the machine from power before cleaning interior and exterior b Small items can be washed in cleaning solution and
24. er LED or photocell surfaces will reduce the signal strength When this happens the scanner should be wiped clean 6B 2 Scanner Signal Strength Adjustment Located below the bar graph display Adjust so both the 9th and 10th segment 9 1 2 setting of the bar graph are lit at the Same time when nothing blocks the scanner light beam We suggest this setting because the 10th segment is the highest display possible but in fact you may have the signal strength adjustment higher than 10 By setting 9 1 2 you can see the signal strength is not excessively high and is in fact slightly less than 10 Small tablets and amber colored gel caps may count best at a lower signal setting because they do not block the scanner light beam as effectively as large tablets Never set below 6 6B 3 Clear Gel Cap Center Overlap Used only when clear gel caps are counted Never use with solid opaque products The green LED indicates when a special time delay circuit is rejecting a scanner signal that occurs too soon after a previous signal We refer to the signal rejection as a time delay overlap The signal we want to reject is the false signal caused by red light from the scanner LED passing through the center of a clear gel cap As a gel cap falls through the scanner light beam the light intensity is reduced by refraction from the thick edge of the gel cap At the moment the initial scanner signal occurs the time delay begins to function and any other signal that occurs
25. er plate with slot to clear the flag funnel holders and funnels Wipe down the diverter flag the aluminum base through which the flag extends and the machine surfaces around the diverter head 8 3 General cleaning for non contact surfaces Always start the complete cleaning of the machine with Step 1 a While the contact parts listed above are off the machine or before cleaning with anything else open the front control door and rear door Use a cloth or a brush to wipe or low pressure lt 50 psi compressed air to blow out dust and debris Do not use cleaning solution inside the machine as a regular practice Under very dirty conditions I can suggest a cleaning procedure if you contact Deitz Co This part of the cleaning process will blow dust on all other parts so do this first b Wipe all exterior surfaces with a damp cloth Do not spray from a spray bottle Try to prevent liguids from dripping into the machine c Carefully wipe down the DC3 electronic counter PC3 power control panel and the scanner signal display panel These electronic panels are especially susceptible to damage if liguids enter the preset count register or switches d Dry with a clean cloth or paper towel e Apply stainless steel cleaner polish on non contact surfaces to keep the machine looking good f After cleaning cover the machine with the vinyl cover 8 4 Cleaning the AS1Air Supply and AGS components Disconnect the AS1 blower from power before c
26. he DC3 loads the preset value into the counter each time the counter resets to zero When the main power is turned on the reset to zero function causes the existing preset number to be loaded Also when counting is taking place and the preset value is reached the settings on the preset value are reloaded Therefore if the preset value is changed while the DC3 is counting the counter will reset at the previous preset number and then load the new number for following counts Always press reset after changing the preset value 6 4 When to use the Center Overlap CO Also known as SRD on an earlier version machine When counting opaque product this feature is not used and the adjustment is turned fully CCW The CO must be used for translucent products or products with a center hole For a CO theory explanation see Center Overlap Information section below See photos Section 2 1 6 5 Setting the CO Adjustment With the TC running product at a rate slightly less than the maximum desired rate turn the CO adjustment knob fully CW The indicator light now should flash once for each piece counted It may appear to be on continuously 6 5a Slowly turn the CO adjustment knob CCW until the green CO indicator light is observed to flash nearly in sequence with the product passing through the scanner beam one short pulse per capsule or gel cap 6 5b Turn the adjustment slightly more CCW so the indicator light flashes once every few pieces This indica
27. ign the rim on the machine The pin or fork location was slightly adjustable so that the rim position could be adjusted to put the product trajectory through the scanner beam centerline There are two different pin fork configurations the old and the new arrangements 4B 5 Rim Location Pin Fork Located on the rim under the vibrator feed tray The fork is attached to the rim The pin is mounted on a threaded shaft supported by a bracket attached to the TC top cover The pin location can be changed by turning the threaded shaft Adjustments can be made while the machine is being used See Section 3 photo 3 4B 6 Adjustment Procedure Observe the product trajectory If it isn t falling between the dots on the scanner adjust the rim relocation pin which will move the pin and the fork causing the rim to pivot on the center hub The knob should be loosened slightly while adjustments are made When the trajectory is satisfactory tighten the hub knob again Rim center hub knob also known as rim hold down knob 4B 7 Flow Corrector Guide Small wedge shaped guide that is located at the edge of the glass at the point of product discharge from the guide channel It will stabilize an erratic moving tablet or caplet as it leaves the turntable In some cases use of the flow corrector will make a rim location change unnecessary See Section 4 9 about use of this guide SECTION 5 THE AIR GUIDE ASSEMBLY AGS OPTION The Air Guide System is a supe
28. ignals until the number of tablets counted equals a preset number entered into the count register at which time the counter resets and the flow of tablets is diverted to the other fill station Special circuits make it possible to count clear gel caps which would otherwise present a problem for photoelectric type counters These machines can count standard type products at 1200 to 3000 units per minute SECTION 2 MAJ OR COMPONENTS OF THE TC 2 1 MAIN CONTROL PANEL A PC3 Power Control Module AD0997 B DC3 Electronic Counter ADO770 2 C Bottle Counter D Scanner Signal Display Panel AD0985 2 2 DIVERTER HEAD ASSEMBLY A Scanner AD0956 B Diverter Flag C Solenoid Assembly D Funnel Assembly 2 3 RIM ASSEMBLY A Product Guides B Spring Loaded Deflector Guide C Air Guide Nozzle Assembly D Rim Cover 2 4 GLASS PLATE ASSEMBLY A Glass Plate B Glass Support Ring C Glass Protecting Washer D Ring Nut 2 5 VIBRATOR HEAD ASSEMBLY A Vibrator B Feed Tray C Sieve Plates D Dust Cup 2 6 HOPPER ASSEMBLY A Hopper B Extension 2 7 ELECTRONIC ASSEMBLIES A Interconnection Board AD0995 B Power Supply ADO986 C Signal Processor Board AD0984 D Scanner Signal Display Panel AD0985 2 8 ASTAIR SUPPLY ASSEMBLY A Regenerative Blower B Air Filters SECITON 2 1 MAIN CONTROL PANEL s 2 1A PC3 Power Control Module ee jao z ADO0997 A blue panel mounted in the CONTROLLER MNA IZKA control door Switches on this panel 4 o
29. inner edge of the outer flow guide or it will lose its necessary springy quality Bend the wire to get everything in place If the Air Guide System option is part of the TC machine see AGS information 4A 5 Glass Turntable Should turn flat There should not be a variation of greater than 1 16 up and down as the glass turns Wobble is often caused by foreign matter dirt between the bottom of the glass surface and the top of the glass support ring A small imperfection close to the main hub is greatly magnified at the outer edge of the glass Be sure the surface between the glass and the support ring are clean The clear plastic washer is used between the top of the glass and the ring nut 4A 6 The hopper gate opening and PC3 Feed Control adjustment should be set so that the turntable will not overload with product resulting in guide channel blockage The Automatic Vibrator Feed Control AFC modification will prevent a turntable overload 4A 7 Itis not necessary to use the tablet guide height guide and the capsule wire guide if the Air Guide System AGS is used SECTION 4B RIM LOCATION ADJ USIMENT INSTRUCTIONS Count accuracy depends on tablet trajectory after it falls from the edge of the glass turntable It must fall through the scanner beam centerline blocking the light from the red light emitting diode LED on one side of the scanner gap from the photocell on the other side A tablet that falls off center may not sufficiently
30. ions There is a band around the bottom of the center hub above the glass An extension from the band should be adjusted to deflect product away from the hub to the deflector guide so that the product can not get behind the back side of the diverter guide where it attaches to the hub There is a metal block attached to the top of the diverter blade shaft The block triggers the sensor that is part of the Automatic Vibrator Feed Control AFC See sections 2 3C and 7 for details 4 9 Flow Corrector Guide FC Attached to rim segment hardware under the end of the guide channel It has a wedge shaped flat surface intended to fill in the space between the edge of the glass turntable perpendicular line to the guide channel It allows product dropping from the turntable to fall from an edge that is square with the guides rather than at the angle presented by the glass edge It is adjusted so the product will not stop on its surface The trailing edge is bent and polished to present minimal resistance to passing product Product will touch this guide as it drops but only enough to assure that the drop is straight See photo below SECTION 4A RIM GUIDES ADJ USTMENT PROCEDURES AND COUNT ACCURACY TIPS There are a few basic rules to follow for most types of tablets and capsules You should use the capsule or tablet guide for the appropriate product The turntable speed must be suitable for the difficulty of aligning the product to the channel This s
31. leaning a Remove both air filters Examine the output filter for dust and debris Normally it is clean because the input filter has filtered everything If the output filter is dirty the input filter is worn out or the blower impeller is wearing badly Check to see why the output filter is dirty Examine the input filter One side should be dirty Tap the filter on a hard surface to shake the dust out of the filter If the filter is too dirty to successfully clean replace it Never interchange the input and output filters The opposite side of each filter is contaminated b Wipe down the AS1 stainless steel cabinet c Air hose if the filters are working correctly the air hose should be clean If you want to wash the hose in the sink use soap and water Dry by v attaching the hose back to the ASland turn it on Be careful you don t drain water from the hose into the AS1 filter d Air nozzle assembly do not disassemble unless necessary I suggest washing it as an assembly and using compressed air to blow it dry These are suggested procedures that should not be considered complete or suitable for every Pharmafill TC user You are responsible for determining what cleaning procedure is necessary for your application CONTACI SURFACE MATERIALS AcetalThermoplastic NSF and USDA compliant Meets FDA 21 CFR 177 2480 and ASTM D6100 Stainless Steel Sheet Metal Fabrications Type 304 widely used form of stainless steel recommended for food
32. lly point toward the left LED indications on this board show the status of machine operations There is one LED that always blinks 2 7D Scanner Signal Display Panel AD0985 Attached to the signal processor by a flat ribbon cable It is mounted on the control door There is a bar graph display signal intensity adjustment and clear gel cap center overlap adjustment on the panel that are operator adjustments On the opposite side of the panel inside the machine are three small trim pot adjustments that the operator will not normally adjust The DC3 connects to this board See photos in Section 2 1D and Section 6B SECITON 2 8 ASTAIR SUPPLY ASSEMBLY _ 2 8A Regenerative Blower Installed in a stainless steel enclosure or inside the LPA2 Lift Platform when used as part of an automatic ABF2 line This source of low pressure high volume air is very suitable for the air guide system purpose Unlike most common compressors it does not condense ____ vapor in the air it is oil less quiet and small 2 8B Air Filters There are two paper filters used with the blower One cleans the incoming air and the other cleans the outgoing air Normally the outgoing filter is clean Never interchange the filters opposite sides are contaminated SECTION 3 HOW TO PUT THE TC IN SERVICE 3 1 To install the glass plate remove the rim by loosening the black knob in the center of the rim hub Remove the ring nut and the plastic protective wa
33. ls in the bottle This is because one or more pills pass the scanner without being detected If you get undercounts one or more too few in the bottle it is unusual If you get an undercount in every bottle there is no good explanation If you get a mix of one undercount and one overcount it is usually a diverter flag movement problem Hopefully this information will help you understand the reason and solution for count problems PHARMAFILL TWO YEAR LIMITED WARRANTY New Machinery Deitz Company Incorporated Deitz Co manufacturer of the Pharmafill line of bottle filling equipment warrants to the original purchaser that the machinery described below is free from material and workmanship defects Deitz Co s sole obligation under this warranty shall be to provide without charge to the original customer repair or replacement at Deitz Co option of failed components or subassemblies within two years from the date of delivery to the customer The following limitations apply Warranty does not apply to 1 any defect malfunction or failure caused by misuse abuse accident or faulty installation 2 the glass turntable plate 3 machines not manufactured by Deitz Co ie bottle capper or labeler when they are specified recommended or installed as part of a bottle filling line assembled by Deitz Co 4 electric motors and clutch assembly The Pharmafill Two Year Warranty applies when there is no other manufacturers warranty to consider The
34. lter can no longer be cleaned or if a hole is found 4 Capsule Guide somewhat fragile and can break if bent too much If you have a maintenance problem that is difficult to solve call Deitz Co for assistance 732 681 0200 SECITON 9 TABLET COUNTER ADJ USIMENIS FOR ACCURACY The tablet counter is designed to be accurate when used within the limits of its accuracy and when it is in good operating condition In the following explanation the term pills will include tablets capsules caplets gel caps and examples of a solid oral dose type product in general TC1 TC2 TCA2 Operation Theory The TC photoelectrically counts pills as they drop from the glass plate through a scanner Count is accumulated on the DC3 electronic counter When a preset number is reached the counter resets to 0000 and produces an output which operates the diverter head deflector flag Pills drop into one of two filling stations depending on the position of the deflector flag L A IC uses a photoelectric scanner to detect pills as they fall from the edge of the glass turntable plate Pills must fall through the middle of a light beam emitted by a red LED light source The light beam is aimed at a photocell that is located directly opposite the LED The centerline of the beam is marked by two dots that are machined in the scanner Each dot is precisely located above the photocell and LED Pills must fall between the dots as close to the centerline as possible 2 Th
35. ly position 3 amp 11 amp T2 3 13 Check the scanner signal intensity on the scanner signal display panel Using the knob under the bar graph display set the signal level so the 9th and 10th bars are red As tablets drop through the scanner beam observe the scanner signal deflection Ideally the signal will drop to as low as 1 or 2 when the scanner beam is briefly blocked by the falling tablet The red LED light to the left of the bargraph will go out when a count occurs and be lit in between falling tablet detection 15 3 14 Load the number of pills to be put into a bottle into the preset register by pressing the buttons above or below each of the four digit displays After loading the number push the reset load button 16 3 15 The Clear Gel cap Center Overlap adjustment is used only for clear gel caps For other type products keep this adjustment fully CCW The green light should not light during a non gel cap count See Section 6 for more information 15 3 16 Adjust the Automatic Vibrator Feed target so the vibrator stops when the spring loaded deflector guide tip is move approximately 1 inch by a load of pills on the glass plate When the light at the rear of the sensor turns on the vibrator should stop 13 3 17 Adjust the bottle table height so the funnels are about 1 4 above the bottle opening Adjust the bottle locator assembly to or fro to line up bottles quickly under the funnel 5 BE SURE HUB PIN FITS IN SLOT
36. nt is almost completely CW TDS adjustment procedures are explained below 6B 6 Trigger Point Set TPS The scanner produces a signal proportional to the amount of light that falls on the photocell and the setting of the scanner signal strength adjustment on the front panel When a pill falls through the scanner beam it blocks the light and causes the signal to drop The signal must fall below the trigger level to produce a count signal The TPS trim pot adjustment sets the trigger point We set the trigger point at 5 To set the trigger point adjust the scanner signal strength adjustment to the front panel for a bargraph display of 5 Adjust the TPS until the red LED next to the bargraph is lit at a level of of 5 and is out at 4 After adjusting return the scanner Signal level to between 9 and 10 6B 7 Scanner LED Intensity Adjustment Adjusts the red LED intensity in the scanner so that the bargraph display will indicate 9 1 2 when the front panel signal Strength adjustment is at mid range The LED will dim slightly over time to this adjustment allows you to increase the LED intensity when necessary Eventually the scanner LED will dim more than can be compensated for and must be replaced If this happens contact Deitz Co 6B 8 TDS Adjustment Procedure Enter 5 in the counter register Push reset Line up 9 pills end to end in the guide channel Note which bottle will be filled first Set the motor speed at 5 Switch on the motor and let th
37. ocess Ad r m ee ae Thumb Screws S A ami k A a gt Air Relief Ring 4 a J A 1 Nozzle Rak SECTION 6 EXTERNAL ELECTRONICS SET UP AND ADJ USTMENT 6 1 Before Proceeding The following procedures are performed after the machine is mechanically set up to properly handle the product Load the hopper with product and adjust the product flow guides All machines should be closed and secured 6 2 Set the PC3 Dual Power Controller Motor and Feeder Rates With the main power switch ON and the motor and feed knobs turned fully counterclockwise CCW turn on the motor switch and the feed switch See photos Section 2 1 6 2a Ideal Rates Set the motor speed so that product is discharged at a rate that can be counted accurately Adjust the feeder control so the product fills the turntable from the feeder at a rate in which the turntable is kept as full of product as possible without exceeding the rate at which the product is being discharged 6 3 Set the DC3 Preset Counter Set the preset value for the total number of product to be counted into each bottle by putting the number on the decade switches below the display Each digit may be changed from 0 to 9 by pressing buttons above and below each place When the preset value is set press RESET amp LOAD PRESET The counter will immediately load the number that is on the preset value switches 6 3a Note About the Preset Counter T
38. rating Tighten the two sieve plate knobs so they don t loosen and fall out 7 amp 8 3 8 Put the dust cup under the bottom slot in the feed tray 9 3 9 Turn on the motor switch and adjust the speed to 5 The glass plate should turn Listen for rubbing sounds Be sure the guides do not rub against the glass If they do adjust the guides so they don t rub 10 3 10 Put tablets capsules etc on glass plate entering the guide channel Use the capsule or tablet guide depending on product Adjust channel to be slightly wider than product Eliminate piggyback one on top of another problems For tablets use height guide For capsules use kick out wire guide 10 3 11 If the Air Guide System AGS is part of the machine use the capsule guide at all times Adjust the nozzle level to knock off piggybacks Adjust air pressure by opening the air dump collar at the rear of the nozzle assembly Nozzle ends must always be against the slots in the slotted guide plate If not the air flow will be very ineffective 14 3 12 As tablets drop off the edge of the glass observe their trajectory through the scanner They should drop through the center line of the scanner beam Beam centerline is indicated by two dots machined in the top of the scanner If the trajectory is not centered you can adjust the guide drop off point by adjusting the rim location Turn the rim alignment screw located under the vibrator pan to move the entire rim and guide assemb
39. receive a momentary pulsed signal from the main signal processor board to move the diverter flag Two aluminum links attach between the solenoid center poles and the flag shaft These links must be in good condition and may be lubricated with light oil for reliable operation Never put oil on any part of the solenoid i J _ Diverter Flag Shaft 1 E n 2 2D Funnel Assembly At the bottom of the diverter head assembly is a funnel holder bracket with a pair of funnels installed There are four different size funnels Select a funnel with a bottom opening that closely matches the bottle opening Remove the bottom plate of the funnel holder put the funnels in the holes in the plate and reinstall the plate to correctly install the funnels Funnels do not drop in from the top of the funnel holder See Section 3 photos 5 amp 6 SECITON 2 3 RIM ASSEMBLY 2 3A The Rim Round stainless steel band that surrounds the glass plate When it is assembled at Deitz Co we use an assembly jig that correctly spaces the spokes We do not recommend disassembling the rim The rim contains the load of tablets and supports the various product guides The glass turntable plate should not rub against the rim The rim is held in place by aligning the alignment fork on the side of the rim band with the adjustable alignment pin located under the vibrator feed tray The rim is held in place by the center knob through the rim hub 2 3B Product Guides
40. rior method of preventing product blockages at the beginning of the guide channel and for deflecting piggybacked pairs of product inside the guide channel It consists of a manifold nozzle assembly that attaches under the rim guide block through two attachment slots The manifold assembly is fabricated with two different air input openings The correct opening depends on the source of air The pointed capsule guide is always used with the AGS option The tablet guide capsule kick out wire guide and height guide are no longer necessary 9 1 Air Source May be your already available compressed air source or the AS1 blower The air must be low pressure dry clean and regulated 5 2 Using Your Air We supply a manifold with a 1 4 inch pipe tap threaded hole fora fitting of your choice Your air should be regulated to less than 20 psi Compressors create moisture by condensation and are often lubricated so filtering will be necessary 5 3 Using the AS1 Air Supply We supply a manifold with a large opening suitable for our 1 1 4 air delivery hose The AS1 regenerative blower is our recommended air source It produces high volume low pressure low noise generally cleaner air than does a compressor We provide a stainless steel enclosure a fuse a power switch and two paper element filters Filter 1 cleans the air entering the blower inlet Filter 2 cleans the air again as it leaves the blower to trap possible internal contamination The
41. s circuit makes it possible to count clear gel caps accurately A green LED located above the overlap adjustment knob flashes when product pass the scanner beam Always set at minimum CCW when counting pills that are not perfectly clear SECITON 2 2 DIVERTER HEAD ASSEMBLY 2 2A Scanner AD0956 Tablets fall through the scanner beam when they drop from the edge of the glass turntable plate A bright red LED provides the light beam that falls on a photocell assembly on the opposite side of the scanner gap The scanner signal level depends on the intensity of the light received by the photocell and the setting of the scanner signal intensity adjustment It is indicated by the scanner signal display panel Beam Centerline Indicator Two small dots are machined in the top of the scanner over each side of the scanner beam gap One is over the center of the red LED and the other is over the center of the photocell When tablets are falling through the scanner gap they must fall precisely between these dots The rim location adjustment should be used to adjust the tablet flow so it does fall between the dots E Model TA 2 2B Diverter Flag Described as a flag because of its shape it directs the tablets to the right or left fill funnels The flag shaft must be straight and the flag must move freely It is pulled from side to side by a pulsed signal to a solenoid assembly located behind the diverter head 2 2C Solenoid Assembly Two electric solenoids
42. se a pill enters the scanner beam before the preceding pill leaves the scanner beam 5 The scanner signal level must be kept above 7 and ideally at 9 when no pills block the scanner beam A signal level below 7 may cause count problems 6 The scanner signal level should drop to at least 3 when a pill is passing through the scanner Ideally it will drop to 1 or 2 If it doesn t the pill is probably not dropping through the centerline of the scanner beam Adjust the rim location pin to move the pill flow as required 7 The diverter head deflector flag must move freely If it feels tight if it is bent or if it binds at any point in it s movement it will cause count problems 8 The diverter head actuator delay must be adjusted correctly This is an adjustment inside the TC and is initially made at the factory If it is not adjusted right you will get one pill over and or one under per bottle 9 If you are not counting a clear gel cap keep the clear gel cap center overlap fully CCW You should not see the green LED flash If the clear gel cap adjustment is turned CW and the LED flashes you may be allowing pills to pass without being counted overfilled bottles 10 If you are counting a clear gel cap you must set the clear gel cap center overlap If you do not set this adjustment you will get a substantially under filled bottle Adjustment procedure is described in Section 6 Adjustments 1 Scanner Keep the face of the red LED flu
43. sh with the stainless steel inner cover of the diverter head Loosen the scanner mounting screw to move the scanner Keep the scanner in it s slot Do not try to rotate the scanner to be at any other angle Scanner signal should be at 9 Adjust the black knob below the level bargraph to attain a 9 If you can not get as high as 9 you should adjust the scanner adjust trim pot located on the backside of the scanner display panel inside the machine It is labeled SCAN ADJ If you still can t get as high as 9 call for assistance See drawing below or photo in Section 6B GUIDE BLOCK WITH GUIDES RIM LOCATION ADJ USTMENT FLOW CORRECTION WEDGE 2 Guides Located on the rim Adjust the guide width to be slightly wider than the pill They should be wide enough so that the pill never jams in the guide channel but not so wide the pill bounces from side to side If you are using the height guide set it so it knocks off potential piggybacks For capsules use the capsule kick out wire to accomplish this If some pills appear to fall off the glass and veer to one side outside the scanner beam use the wedge shaped flow correction guide to present a square edge to the pill where it drops from the glass If all pills appear to drop to one side of the scanner beam adjust the rim locating pin under the vibrator tray to move the rim guide drop off point until they fall through the centerline of the scanner beam Loosen the big black rim tightening knob rim hub center
44. sher Picture 2 3 2 Install the glass with aluminum support plate on the bottom If plate is not glued to the glass put the plate over the hub first The machined surface surrounding the hole must be facing down Align the slot in the aluminum plate with the pin in the hub D 3 3 Put the plastic washer on top of the glass over the hub and screw down the ring nut Hand tighten Be sure the glass is level on the hub 2 3 4 Put the rim on the hub Be sure the rim alignment fork surrounds the pin correctly under the vibrator feed tray Lift the tray slightly to get the rim in position 3 3 5 Connect the multi pin connectors of the power cable together to get power to the TC Be sure the main power switch on the TC is off This is the wide red switch on the PC3 power control module Plug the TC into a 115 vac power source 4 3 6 The diverter head has a funnel holder assembly located below the bottom opening Install funnels if there are none in place Use the largest size funnel that matches the bottle opening Remove the stainless steel bottom plate from the diverter head drop funnels through the holes and reinstall 5 amp 6 3 7 he IC is supplied with a solid plate inside the vibrator feed tray The plate can be replaced by a sieve plate The sieve plate holes allow dust and pill chips to drop through to be collected by the dust collecting box Bend the sieve plate ends down so the plate doesn t rattle when the tray is vib
45. so be necessary to remove the cover and clean the area under the cover if you see dust under the cover The masked photocell cover serves two purposes It allows a narrow slice of the LED light beam to fall on the photocell This makes the photocell responsive to small narrow spaces between pills as they pass through the scanner beam A more responsive the photocell allows faster pill delivery and produces a more accurate count Important conditions that must be maintained L Pills must drop one at a time and there can be no side by sides or piggybacks This is controlled by accurate guide channel width adjustment and height guide adjustment or air guide nozzle adjustment when air guides are used 2 Pills must drop as close to the middle of the scanner beam as possible Adjust the rim location pin adjustment screw located under the vibrator feed tray as required 3 Pills must follow each other as they drop If a pill appears to drop off to one side outside the normal flow it may miss the scanner beam Keep the guide channel width as narrow as possible and use the flow corrector guide wedge if necessary 4 Turntable speed must not be higher than the accuracy speed limitation Test the TC with each different type pill to see what the fastest turntable speed will be for accurate counts If the turntable is too fast the trajectory of pills leaving the glass plate will be too flat The scanner will not detect the space between pills becau
46. ter rim The TC2 has a 20 diameter rim They are assembled as a right or left hand version A right hand TC2 R machine has the diverter head located on the right end of the machine A TC2 L has the diverter head on the left end If the optional air guide system AGS is installed the TC2 R becomes a TCA2 R TC2 machines can be used semi automatically as a tabletop set up where the operator manually moves bottles in and out of the fill stations They can also be added to a fully automatic filling line with a conveyor and automatic bottle indexing Automatic lines are described as ABF2 and DABF2 All semi automatic machines are prewired for easy conversion to full automation at a later date Tablets are loaded into a bulk hopper A vibratory feed tray delivers product from under the hopper to the rim assembly and glass plate As the plate turns it delivers tablets to a guide channel attached to the rim that lines up tablets single file The line of tablets leave the guide channel as they fall off the edge of the turntable They pass through the diverter head where the tablet flow is directed to one of two fill station funnels Bottles are placed under the funnels When a bottle is filled the machine directs the flow to the other fill station and the filled bottle is replaced with an empty bottle Counting is accomplished by a tablet falling through a photoelectric scanner beam creating a scanner signal The electronic counter accumulates these s
47. tes that the delay is sufficient to slightly overlap some products entire signal and therefore overlaps most of any product s signal SECITON 6B SCANNER SIGNAL DISPLAY PANEL AD0985 The scanner signal display panel shows the quality and strength of the scanner Signal indicates when a count occurs indicates when the center overlap delay is in effect provides adjustment of the scanner signal strength and adjusts the amount of delay being applied to the scanner signal when center overlap is being used Three small trim pot adjustments are located on the backside of the panel which is accessed by opening the control door These adjustments are called time delay trigger point and scanner LED intensity See photo Section 2 1D and Section 3 photo 15 6B 1 10 segment Bar Graph Display Acts like a signal strength meter It shows the scanner signal strength When the 10th segment is lit the signal from the photocell inside the scanner is maximum Signal strength depends on how much light from the scanner red LED light source falls on the photocell and on the adjustment located below the bar graph display As pills fall through the scanner light beam they momentarily block the light from the photocell and the signal strength decreases very rapidly Whenever the signal drops below the trigger point level factory set at 5 the red LED to the left of the bar graph flashes and a count signal is sent to the DC3 counter Dust accumulating on the scann
48. uld allow the blade to deflect toward the center under a big load The tip of the blade can be bent to allow 2 rows of product to pass without deflecting the blade 7 2 Target Block The target is a half round metal block mounted on top of the deflector shaft When the blade moves toward the center hub under a heavy load the target rotates at the top of the deflector shaft A sensor aimed at the target detects this movement and will turn off the vibrator when the deflector blade moves past an adjustable limit See Section 3 photo 13 7 3 Sensor A proximity sensor detects the leading edge of the target block The sensor must be very close to the target approximately 1 8th inch When the target is detected a yellow LED locator at the rear of the sensor lights The sensor is 2 part sensor head and cable WE mount the sensor in a metal bracket that locates under the rim hold down knob on top of the rim cover if used See Section 3 photo 13 Using the AFC Function 7 4 Feed rate is adjusted on the PC3 control to deliver product at a slightly greater rate than it is being counted overfeed 7 5 The target block is adjusted to control the AFC on off function To adjust the target the deflector blade must not be deflected no pills pushing against the blade 7 6 Loosen the target block set screw Move the target so the flat area is in front of the sensor The leading edge of the round part of the target should be about 1 4 inch from the s
49. ust be adjusted the adjustment trim pot is located next to the scan adjust and time delay set trim pots inside the TC It is labeled TPS 5 Turntable Speed Accuracy Test Set up the TC for accuracy Begin the turntable speed at 5 Count 30 pills from the same bottle at least 10 times The counter should show 30 Increase the speed to 5 1 2 Count the bottle contents 10X again Continue raising the turntable speed in 1 2 increments until you get an error This indicates the speed at which two pills appear to overlap one another to the scanner There is still a Space between the pills but the more horizontal trajectory is causing the overlap in the scanner beam This is the upper limit of the pill delivery rate The upper limit depends on pill shape and size There are tricks that increase the rate Call for tips 6 Observation Watch the pills fall from the glass through the scanner beam between the dots Keep an eye out for piggy backs Be sure there are none Watch the pills fall Straight down If one or more veers out of the flow periodically determine why Ifthe guide channel is too wide it will contribute to the problem Use the flow corrector wedge guide if necessary Adjust the rim guide location if necessary Check the scanner signal level Is it as high as 9 and does it drop at least below 3 when pills pass the scanner If not check to see why it isn t Most of the count errors can be corrected The usual error is overcounts too many pil

Download Pdf Manuals

image

Related Search

Related Contents

Fagor CFC-40AX  取扱説明書 - パラマ・テック  Severin EK 3161  Cisco Systems OL-1911-05 User's Manual  ShadowProtect Desktop Edition User Guide  Vanguard Heating VMH26PRA User's Manual  Feature - LED蛍光灯の特徴  Quicklube Lubrication System, Maintainence and  Multi Sensor - Jacob Jensen Store  Buena Depth Cue v2 User Manual  