Home
        Manual TA440
         Contents
1.  Appendix A         ALNOR    Alnor Products  TSI Incorporated  Visit our website www alnor com for more  information     USA Tel   1 800 874 2811  India Tel   91 80 67877200  China Tel   86 10 8219 7688    Singapore Tel   65 6595 6388    P N 1980584 Rev  F      2014 TSI Incorporated       AIRFLOW    INSTRUMENTS    Airflow Instruments  TSI Instruments Ltd   Visit our website at  www airflowinstruments co uk for more  information        UK Tel   44 149 4 459200  France Tel   33 491 11 87 64  Germany Tel   49 241 523030    Printed in U S A     
2.  Check the individual parts against the list of components  below  If anything is missing or damaged  notify TSI immediately     1  Carrying case   2  Instrument   3  USB cable   4  CD ROM with downloading software        This page intentionally left blank     Chapter 1    Chapter 2    Setting up       Supplying Power to the Alnor AVM440 Airflow Instruments  TA440    The Alnor   AVM440 Airflow    Instruments TA440 is powered with  four size AA batteries     Installing the Batteries   Insert four AA batteries as indicated by the diagram located on  the inside of the battery compartment  The Alnor AVM440  Airflow  Instruments TA440 is designed to operate with either alkaline or  NiMH rechargeable batteries  although it will not recharge NiMH  batteries  Battery life will be shorter if NiMH batteries are used   Carbon zinc batteries are not recommended because of the  danger of battery acid leakage     Using the Optional AC Adapter   When using the AC adapter  the batteries  if installed  will be  bypassed  Be sure to provide the correct voltage and frequency   which is marked on the back of the AC adapter  The AC adapter  will not recharge the batteries     Using the Telescoping Probe   The telescoping probe contains the velocity  temperature  and  humidity sensors  When using the probe  make sure the sensor  window is fully exposed and the orientation dimple is facing upstream        For temperature and humidity measurements  make sure that at  least 3 inches  7 5 cm  of the p
3.  described in the operator s manual  to be free from defects in workmanship  and material for 24 months  or if less  the length of time specified in the operator s  manual  from the date of shipment to the customer  This warranty period is inclusive of  any statutory warranty  This limited warranty is subject to the following exclusions and  exceptions     a  Hot wire or hot film sensors used with research anemometers  and certain other  components when indicated in specifications  are warranted for 90 days from the date of  shipment     b  Pumps        warranted for hours of operation as set forth in product or operator   s  manuals     c  Parts repaired or replaced as a result of repair services are warranted to be free from  defects in workmanship and material  under normal use  for 90 days from the date of  shipment     d  Seller does not provide any warranty on finished goods manufactured by others or on  any fuses  batteries or other consumable materials  Only the original manufacturer s  warranty applies     e  This warranty does not cover calibration requirements  and seller warrants only that  the instrument or product is properly calibrated at the time of its manufacture   Instruments returned for calibration are not covered by this warranty     f  This warranty is VOID if the instrument is opened by anyone other than a factory  authorized service center with the one exception where requirements set forth in the  manual allow an operator to replace consumables or pe
4.  is full Download data if  message appears desired  then DELETE  ALL memory     Fault in instrument Factory service  required on instrument     Remove the probe from excessive temperature immediately   excessive heat can damage the sensor  Operating temperature limits    can be found in Appendix A  Specifications        11    12     This page intentionally left blank     Chapter 5    Appendix A    Specifications       Specifications are subject to change without notice     Velocity Probe    Range  0 to 6000 ft min  0 to 30 m s    Accuracy      3  of reading or  3 ft min   0 015 m s    whichever is greater    Resolution  1 ft min  0 01 m s     Duct Size   Range  1 0 to 500 inches in increments of 0 1 in    2 5 to 1270 cm in increments of 0 1 cm     Volumetric Flow Rate   Range  Actual range is a function of actual velocity  and duct  size    Temperature from Velocity Probe   Range  14 to 140 F   10 to 60  C   Accuracy      0 5   F   0 3  C   Resolution  0 1   F  0 1   C     Relative Humidity from Velocity Probe   Range  5 to 95  RH   Accuracy      3  RH   Resolution  0 1  RH    Wet Bulb Temperature from Velocity Probe   Range  40 to 140 F  5 to 60       Resolution  0 1 F  0 1  C     Instrument Temperature Range    Operating  Electronics   40 to 113  F  5 to 45  C   Operating  Probe   14 to 140     10      60  C   Storage   4 to 140  F   20 to 60  C     Instrument Operating Conditions    Altitude up to 4000 meters   Relative humidity up to 80  RH  non condensing  Pollution degr
5.  the CALIBRATION menu  These field  adjustments are intended to make minor changes in calibration to  match a user s calibration standards  The field adjustment is NOT  intended as a complete calibration capability  For complete  multiple   point calibration and certification  the instrument must be returned to  the factory     Cases    If the instrument case or storage case needs cleaning  wipe it off with  a soft cloth and isopropyl alcohol or a mild detergent  Never immerse  the Alnor AVM440 Airflow Instruments TA440  If the enclosure of the  Alnor AVM440 Airflow Instruments TA440 or the AC adapter  becomes broken  it must be replaced immediately to prevent access  to hazardous voltage     Storage    Remove the batteries when storing the unit for more than one month  to prevent damage due to battery leakage     10     This page intentionally left blank     Chapter 4    Chapter 5    Troubleshooting       Table 5 1 lists the symptoms  possible causes  and recommended  solutions for common problems encountered with the Alnor  AVM440 Airflow Instruments TA440  If your symptom is not listed  or  if none of the solutions solves your problem  please contact TSI     Table 5 1  Troubleshooting the Alnor AVM440   Airflow Instruments TA440    Symptom Possible Causes Corrective Action         plug in AC adapter   contacts     Velocity reading Fluctuating flow Reposition probe in   fluctuates   less turbulent section   unstable or use longer time  constant     Instrument Error   Memory
6.  to provide you with maximum flexibility and power  To install this  software on your computer  follow the instructions on the label of the  LogDat2    CD ROM     To download data from the Alnor AVM440 AIRFLOw    TA440  connect  the supplied computer interface USB cable to the Alnor  AVM440 Airflow Instruments TA440 and to a computer USB port   Then run the LogDat2    downloading software  Within the LogDat2     software  either select the tests to be downloaded or double click on  a test to open it     8 Chapter 3    Chapter 4    Maintenance    The Alnor AVM440 Airflow Instruments TA440 requires very little  maintenance to keep it performing well        Recalibration    To maintain a high degree of accuracy in your measurements  we  recommend that you return your Alnor AVM440 Airflow Instruments  TA440 to TSI for annual recalibration  Please contact one of TSI   s  offices or your local distributor to make service arrangements and to  receive a Return Material Authorization  RMA  number  To fill out an  online RMA form  visit TSI   s website at http   service tsi com     U S   amp  International   TSI Incorporated TSI Instruments Ltd   Alnor Products Stirling Road   500 Cardigan Road Cressex Business Park    Shoreview MN 55126 3996 High Wycombe  Tel   800  874 2811 Bucks   651  490 2811 HP12 3ST United Kingdom  Fax   651  490 3824 Tel   44  0  149 4 459200  Fax   44  0  149 4 459700       The Alnor AVM440 Airflow Instruments TA440 can also be  recalibrated in the field using
7. AIR VELOCITY METER  ALNOR   MODEL  AVM440 AVM440A  AIRFLOW    INSTRUMENTS  MODEL TA440 TA440A       OPERATION AND SERVICE MANUAL    P N 1980584  REV F  SEPTEMBER 2014             ALNOR    AIRFLOW       START SEEING THE  BENEFITS GF  REGISTERING TODAY     Thank you for your TSI instrument purchase  Occasionally  TSI releases  information on software updates  product enhancements and new  products  By registering your instrument  TSI will be able to send this  important information to you     http   register tsi com  As part of the registration process  you will be asked for your comments    on TSI products and services    515 customer feedback program gives  customers like you a way to tell us how we are doing        UNDERSTANDING  ACCELERATED        TSI Incorporated   Visit our website www tsi com for more information     USA Tel   1 800 874 2811 India Tel   91 80 67877200  UK Tel   44 149 4 459200 China Tel   86 10 8219 7688  France Tel   33 4 91 11 87 64 Singapore Tel   65 6595 6388    Germany Tel   49 241 523030      2013 TSI Incorporated Printed in U S A     Copyright    TSI Incorporated   2007 2013   All rights reserved     Address  TSI Incorporated   500 Cardigan Road   Shoreview  MN 55126   USA    Fax No    651  490 3824    Limitation Of Warranty And Liability  effective April 2014    For country specific terms and conditions outside of the USA  please visit www tsi com      Seller warrants the goods  excluding software  sold hereunder  under normal use and  service as
8. IR OR    REPLACEMENT OF THE GOODS IN THE CASE OF SOFTWARE  SELLER WILL  REPAIR OR REPLACE DEFECTIVE SOFTWARE OR IF UNABLE TO DO SO  WILL  REFUND THE PURCHASE PRICE OF THE SOFTWARE  IN NO EVENT SHALL  SELLER BE LIABLE FOR LOST PROFITS  BUSINESS INTERRUPTION  OR ANY  SPECIAL  INDIRECT  CONSEQUENTIAL OR INCIDENTAL DAMAGES  SELLER  SHALL NOT BE RESPONSIBLE FOR INSTALLATION  DISMANTLING OR  REINSTALLATION COSTS OR CHARGES  No Action  regardless of form  may be  brought against Seller more than 12 months after a cause of action has accrued  The  goods returned under warranty to Seller s factory shall be at Buyer s risk of loss  and  will be returned  if at all  at Seller s risk of loss     Buyer and all users are deemed to have accepted this LIMITATION OF WARRANTY  AND LIABILITY  which contains the complete and exclusive limited warranty of Seller   This LIMITATION OF WARRANTY AND LIABILITY may not be amended  modified or  its terms waived  except by writing signed by an Officer of Seller     Service Policy   Knowing that inoperative or defective instruments are as detrimental to TSI as they are  to our customers  our service policy is designed to give prompt attention to any  problems  If any malfunction is discovered  please contact your nearest sales office or  representative  or call Customer Service department at  44  0  149 4 459200  Uk     800  874 2811  USA   or  1  651 490 2811  International      CONTENTS    CHAPTER 1 UNPACKING AND PARTS IDENTIFICATION                 CHA
9. PTER 2                0                                           Supplying Power to the Alnor AVM440 Airflow   Instruments     440                                            Installing the Batteries  pp  Using the Optional AC                                                                   Using the Telescoping Probe                                                            Extending the Probe                                             i                                    the PrODS  nenosiri earita                   Connecting to a Computer pp    CHAPTER    OPERATION  ee    Keypad                                                                                                              DISPLAY  SETUP                          SETTING Sissi                                                                BLOW SETUP                                             reel eat      ae  ACTUAL STANDARD SETUP eani aiie aeeai iaai einean aeaa ia adai  DATA LOGGING imiran drintu e de    aa            5                                                   Log Mode Log Settings                                                 Delete  Data                                        Y MEMO                            LogDat2    Downloading                                                                     CHAPTER 4 MAINTENANCE  ee     This page intentionally left blank     Chapter 1    Unpacking and Parts Identification    Carefully unpack the instrument and accessories from the shipping  container 
10. ee 1 in accordance with IEC 664  Transient over voltage category Il    Data Storage Capabilities   Range  12 700  samples and 100 test IDs  one sample can  contain fourteen measurement types     13    Logging Interval   Intervals  1 second to 1 hour    Time Constant   User selectable    Response Time     Velocity  200 msec  Temperature  2 minutes  to 66  of final value   Humidity   lt 1 minute  to 66  of final value     External Meter Dimensions   3 3 in  x 7 0 in  x 1 8        8 4 cm x 17 8 cm x 4 4 cm     Meter Probe Dimensions    Probe length  40 in   101 6 cm   Probe diameter of tip  0 28 in   7 0 mm   Probe diameter of base 0 51 in   13 0 mm     Articulating Probe Dimensions     Articulating section length  6 0 in  15 24 cm   Diameter of articulating knuckle  0 38 in  9 5 mm   Meter Weight     Weight with batteries  0 6 lbs  0 27 kg     Power Requirements   Four AA size batteries  included  or AC adapter  optional  9 VDC   300 mA min       Temperature compensated over an air temperature range of 40 to 150  F  5 to    65  C     The accuracy statement of  3 0  of reading or  3 ft min  0 015 m s   whichever is   greater  begins at 30 ft min through 6000 ft min  0 15 m s through 30 m s     Accuracy with instrument case at 77  F  25  C   add uncertainty of 0 05   F   F    0 03  C   C  for change in instrument temperature    4 Accuracy with probe at 77  F  25  C   Add uncertainty of 0 1           0 2  RH   C   for change in probe temperature  Includes 1  hysteresis     2    14
11. es while  Menu Soft Keys setting a parameter  Press the Menu soft key to    select the Menu selections  which are Display  Setup  Settings  Flow Setup  Actual Std Set up   Data Logging and Calibration              Common Terms  In this manual there are several terms that are used in different       places  The following is a brief explanation of the meanings of those  terms   Sample Consists of all of the measurement parameters stored at    the same time              Test ID A group of samples  The statistics  average  minimum   maximum  and count  are calculated for each test ID  The  maximum number of test IDs is 100    Time The time constant is an averaging period  It is used to   Constant   dampen the display  If you are experiencing fluctuating       flows  a longer time constant will slow down those  fluctuations  The display will update every second  but the  displayed reading will be the average over the last time  constant period  For example  if the time constant is 10  seconds  the display will update every second  but the  displayed reading will be the average from the last 10  seconds  This is also referred to as a    moving average              Menus    DISPLAY SETUP    Display setup menu is where you will setup the desired parameters to  be displayed on the running screen  With a parameter highlighted you  can then use the ON soft key to have it show up on the running  screen or select the OFF soft key to turn off the parameter  Use  PRIMARY soft key to have a 
12. parameter show up on the running  screen         larger display  Only one parameter can be selected as     primary  and up to 2 secondary parameters can be selected at one  time     SETTINGS    Settings menu is where you can set the general settings  These  include Language  Beeper  Select Units  Time Constant  Contrast   Set Time  Set Date  Time Format  Date Format  Number Format   Backlight and Auto Off  Use the  lt  or  gt  soft keys to scroll through the  settings for each option and use the    key to accept settings     FLOW SET UP    In Flow Setup mode  there are 4 types  Round Duct  Rectangle Duct   Duct Area  and Horn  Use the  lt  or  gt  soft keys to scroll through the  types and then press the     key to accept the desired type  To  change the value  highlight the Enter Settings option and press the     key  Use the instructions below to change the value of the type that  you selected     The horn numbers are the models of the horns  For example  100  refers to a horn model number AM 100  Only horns with Model  numbers as follows can be used with this function  AM 100  AM 300   AM 600 and AM 1200  If a horn model number is chosen  the  instrument will return to measuring mode and use a preprogrammed  curve to calculate flow rate from velocity              ACTUAL STANDARD SETUP    Choose Actual Standard measurements and parameters in the  Act Std Setup menu  Within this menu  the user can also select  Standard Temperature  Standard Pressure and a source for the  act
13. rform recommended  cleaning     g  This warranty is VOID if the product has been misused  neglected  subjected to  accidental or intentional damage  or is not properly installed  maintained  or cleaned  according to the requirements of the manual Unless specifically authorized in a  separate writing by Seller  Seller makes no warranty with respect to  and shall have no  liability in connection with  goods which are incorporated into other products or  equipment  or which are modified by any person other than Seller     The foregoing is IN LIEU OF all other warranties and is subject to the LIMITATIONS  stated herein  NO OTHER EXPRESS OR IMPLIED WARRANTY OF FITNESS FOR  PARTICULAR PURPOSE OR MERCHANTABILITY IS MADE  WITH RESPECT TO  SELLER   S BREACH OF THE IMPLIED WARRANTY AGAINST INFRINGEMENT   SAID WARRANTY IS LIMITED TO CLAIMS OF DIRECT INFRINGEMENT AND  EXCLUDES CLAIMS OF CONTRIBUTORY OR INDUCED INFRINGEMENTS   BUYER   S EXCLUSIVE REMEDY SHALL BE THE RETURN OF THE PURCHASE  PRICE DISCOUNTED FOR REASONABLE WEAR AND TEAR OR AT SELLER   S  OPTION REPLACEMENT OF THE GOODS WITH NON INFRINGING GOODS     TO THE EXTENT PERMITTED BY LAW  THE EXCLUSIVE REMEDY OF THE USER  OR BUYER  AND THE LIMIT OF SELLER S LIABILITY FOR ANY AND ALL LOSSES   INJURIES  OR DAMAGES CONCERNING THE GOODS  INCLUDING CLAIMS  BASED ON CONTRACT  NEGLIGENCE  TORT  STRICT LIABILITY OR  OTHERWISE  SHALL BE THE RETURN OF GOODS TO SELLER AND THE REFUND  OF THE PURCHASE PRICE  OR  AT THE OPTION OF SELLER  THE REPA
14. robe is in the flow to allow the  temperature and humidity sensors to be in the air stream        Extending the Probe    To extend the probe  hold the handle in one hand while pulling on  the probe tip with the other hand  Do not hold the cable while  extending the probe as this prevents the probe from extending     Retracting the Probe    To retract the probe  hold the handle in one hand while pulling  gently on the probe cable with the other hand        Connecting to a Computer    Use the Computer Interface USB Cable provided with the  Alnor AVM440 Airflow Instruments TA440 to connect the instrument  to a computer for downloading stored data     For more information on how to download stored data see Chapter     section titled LogDat2    Downloading Software         Pe  This symbol is used to indicate that the data port of the  Alnor AVM440 Airflow    Instruments TA440 is not  intended for connection to a public telecommunications  network  Connect the USB data port only to another  USB port        4 Chapter 2    Chapter 3    Operation       Keypad Functions       ON OFF Key    Press to turn the Alnor AVM440 TA440 on and  off  During the power up sequence the display  will show the following  Model Number  Serial  Number  Software Revision and Last Date  Calibrated        Arrow  AV     Keys   Press to scroll through choices while setting a  parameter         Enter  Key Press to accept a value or condition           Arrow   lt  or  gt   and   Press arrow keys to change choic
15. ual temperature  The actual barometric pressure must be entered  to convert air velocity and volume measurements to actual conditions     6 Chapter 3    DATA LOGGING    Measurements    Measurements to be logged are independent of measurements  on the display  and must therefore be selected under DATA  LOGGING  gt  Measurements     Log Mode Log Settings  You can set Log Mode to Manual  Auto save  or Cont key     e Manual mode does not automatically save data  but instead  prompts the user to save a sample     e In Auto save mode  the user manually takes samples that are  automatically logged     e In Cont key mode  the user starts taking readings and logging  by pressing the   key  The instrument will continue taking  measurements until the   key is pressed again     e Auto save and Cont Key modes have the following additional  Log Settings        Mode Log Settings  Auto save Log Interval  Cont key Log Interval    e Pressing the      keys simultaneously will lock the keypad to  prevent unauthorized adjustments to the instruments  To  unlock the keypad  press the AW keys simultaneously     Delete Data  Use this to delete all data  delete test or delete sample       Memory    This option displays the memory available  Delete All  under  Delete Data  will clear memory and reset the memory available     Operation 7    LogDat2    Downloading Software    The Alnor AVM440 Airflow Instruments TA440 comes with special  software called LogDat2    Downloading Software  which is designed 
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
BigStuff3 4 Stage Dry Nitrous (NOS) System Set Up  Raimondi Globe Valves, Forged High Pressure  User Manual - TEWS TECHNOLOGIES  Kingston Technology ValueRAM KVR1066D3Q8R7SK3/24G  User`s Manual - University of California, Santa Barbara  USER MANUAL    Jabra Freeway  取扱説明書ダウンロード(PDF)  取扱説明書 - 瀧住電機工業株式会社    Copyright © All rights reserved. 