Home
MILKPAK DISPENSER SERVICE MANUAL
Contents
1. Corneli ius Inc IL LU ST RA R TS LI ST 85 6018247 Geta gt MilkPak Service Manual ILLUSTRATED PARTS LIST 3S Description 3S 14L isa 2X10L 2X10L Illuminated nate thermostat cover 7 tep push type choke 205990100 205990100 856016007 4 8 8 2 8 8 8 thumbscrew not shown 583343001 583343001 583343001 583343001 6 Lg 8 EN 10 ima 15 16 EU 18 19 10 11 1 1 14 15 16 17 18 19 0 1 2 2 856018247 9 2006 IMI Cornelius Inc MilkPak Service Manual 2006 IMI Cornelius Inc NOTE 10 856018247 856018247 NOTE 11 MilkPak Service Manual 2006 IMI Cornelius Inc Release Date March 2006 Publication Number 856018247 Visit the IMI Cornelius Web Site at www cornelius asia com for all your Literature needs This manual applies to units which have a serial number from 89A0608XAXXX MILKPAK SERIES IMI CORNELIUS TIANJIN CO LTD
2. MILKPAK DISPENSER SERVICE MANUAL IMI CORNELIUS TIANJIN CO LTD CONTACT INFORMATION The products technical information and instructions contained in this manual are subject to change without notice These instructions are not intended to cover all details or variations of the equipment nor to provide for every possible contingency in the installation operation or maintenance of this equipment This manual assumes that the person s working on the equipment have been trained and are skilled in working with electrical plumbing pneumatic and mechanical equipment Appropriate safety precautions should be followed and all local safety and construction requirements should be met To inquire about current revisions of this and other documentation or for assistance with any Cornelius product contact i G SSL UNITED KINGDOM Internet www cornelius asia com E mail customerservice cornelius com cn 7 IMI Cornelius 2 2 In UK In the P R C 2 Ph 44 1789 763 101 Ph 86 22 2529 0858 Z Fax 44 1789 400 595 Fax 86 22 2529 0865 2 Add Tything Road Alcester Add No 12 Xintai Road 7 Warwickshire B49 6EU TEDA Tianjin 300457 2 2 2 2 SSSI SSS Trademarks and copyrights Aurora Cornelius Decade Hydro Boost Olympus Impulse Sitco Spirit UF 1 Vanguard Venture and Vista are registered trademarks of IMI Cornelius Optifill trademark is pending This document contains proprietary
3. H 285 mm H 430 mm W 258 mm W 120 mm D 230mm D 215mm PART NUMBER PO 3S 14L 35 2X10L 2X10L Illuminated Stainless Steel 89583400G 891418502 NA White Milkpak 89583000G 895832000 891416501 2006 IMI Cornelius Inc 2 856018247 Geta gt MilkPak Service Manual a INSTALLATION Always handle the unit carefully never tilt drop or place it upside down The unit should be stood on a solid counter or shelf Ensure that there is adequate ventilation around the unit In particular ensure that the top and base of the unit is clear of obstruction Allow a 25 mm 1 gap around the unit and a 50 mm 2 breathing space behind the unit Electrical supply required is 220 240 VAC and 50 Hz The unit must be earthed if in doubt consult a qualified electrician DO NOT SWITCH ON unit until the installation has been completed Switching on If the unit has been laying on it s side then allow at least 3 hours in the upright position before switching on The unit should be left on at all times as a domestic refrigerator The temperature within the unit is controlled by means of a thermostat Position No 7 is the coldest On the illuminated version the light ON OFF switch is located on the lower panel 856018247 3 2006 IMI Cornelius Inc MilkPak Service Manual C Gino 3 MAINTENANCE There are no user serviceable parts Repair and maintenance should only b
4. NEUTRAL BROWN LIVE As the colours of the wires in the mains lead of this appliance may not correspond with the coloured markings identifying the terminals in your plug proceed as follows The wire which is coloured green and yellow must be connected to the terminal which is marked with the letter E or by the Earth symbol or coloured green or green and yellow The wire which is coloured blue must be connected to the terminal which is marked with the letter N or coloured black The wire which is coloured brown must be connected to the terminal which is marked with the letter L or coloured red The appliance must be protected by a 10A ASTA approved BS1362 fuse if a IOA BS 1363 plug or a non rewireable plug is used or if any other type of plug is used by a 15A fuse either in the plug or adaptor or at the distribution board 2006 IMI Cornelius Inc 6 856018247 MilkPak Service Manual WARRANTY CONDITIONS EXCLUSIONS I The goods described under this contract All other warranties or conditions as to shall be of normal industrial quality unless specifically stated to the contrary and shall meet any specification laid down in the contract 2 It is for the purchaser to satisfy himself that the goods are fit for the purpose for which they are required For a period of TWELVE MONTHS from the date of delivery the company will repair or replace free of charge any component parts proven to be defective as a result of
5. aire card has been enclosed with your unit Please return this card to ensure the validity of your warranty and to help us improve our cus tomer service The Milkpak dispenser is only one product from a complete range of drinks dispense refrigeration and catering equipment Simply mark the warranty card and return postage paid for information on any of our products manufactured for use in the leisure industry Whilst every effort has been made to ensure accuracy in this guide Cornelius is unable to be held responsible for any loss consequential loss or damage resulting from any action you may take Cornelius policy is one of constant product development and improvement and some details and specifications of your unit may differ from that de scribed here In the event of any query please telephone the Cornelius Service Centre for latest infor mation 856018247 1 2006 IMI Cornelius Inc MilkPak Service Manual C Gies 3 GENERAL INFORMATION Milkpak can be used to dispense cold milk in cafeterias schools hospitals hotels kitchens etc Any BIB Pre Mix products such as flavored milks e g chocolate strawberry soya milk ice tea juices wine can be dispensed as well SPECIFICATION 3S 1L 35 Illuminated 2X10L 2X10L Illuminated outer height Clearances for maximum box size allow 10 mm clearance on both sides of the box 10 mm clearance overall for the depth Box dimensions 3 gallons 2X10L
6. anual KEEPING AND USING MILKPAK 1 Make sure the pack is in good condition upon arrival and check date code stamp Contact supplying dairy if any problems with the pack 2 Milkpak contains fresh milk and MUST BE KEPT UNDER REFRIGERATION AT ALL TIMES If dispenser is already full store extra pack in normal refrigerator 3 Ensure proper stock control use oldest pack first FIRST IN FIRST OUT 4 Ensure a constant supply of fresh milk by using up the pack in a reasonable period of time 5 Do not use milk that has been allowed to stand in the dispenser over the weekend 6 Do not allow milk to freeze Adjust thermostat to ensure milk is dispensed between 2 Cand4 C 7 Keep milkpak and drip tray clean at all times A Remember this is whole fresh milk Ensure it stays cool and fresh CHANGING BAG IN BOX MILK Ensure the box is empty Remove box and tube from tap Insert new box Push back operating lever and hold to keep tap open Feed milk delivery tube through slot into correct location release lever to lock Cut off delivery tube flush with lower face of tap body Oo BE CHANGING ILLUMINATED UNITS Changing the light and starter should be done by a qualified person 856018247 5 2006 IMI Cornelius Inc MilkPak Service Manual C Gino 3 CONNECTING TO POWER IMPORTANT UK ONLY The wires in the mains lead are coloured in accordance with the following code GREEN and YELLOW EARTH BLUE
7. e carried out by a competent person In order to maintain the efficiency of the unit and retain safe hygienic conditions of the bag in box milk a cleaning routine is essential MANUAL CLEANING INSTRUCTIONS Drip tray and tap are dish washer safe Mix 15 ml Milkflo Tube San in 5 litres of hand warm water Clean and sanitise the items listed below DO NOT STORE USED SOLUTION Prepare fresh solution at the end of the serving period Wear rubber gloves during manual cleaning DRIP TRAY Empty and clean whenever full and always at the end of serving period Never leave milk residue overnight 2 SURROUNDING WORK AREA Ensure it is always clean mop up spillages immediately and at the end of a serving period 3 TAP Clean whenever required BUT always at the end of a serving period 4 OUTER CABINET This should be cleaned at the end of a serving period 5 INSIDE THE DOOR AND GASKET Ideally it should be cleaned every time the bag in box is changed but at least once a week To clean behind the gasket ease it away from the metal to get in behind it 6 INSIDE THE CABINET This has to be defrosted before cleaning On no account should metal utensils be used to scrape off the ice leave to defrost Bag in box milk contains fresh milk and must be kept under refrigeration at all times If the dispenser is already full store extra packs in normal refrigerator 2006 IMI Cornelius Inc 4 856018247 Geta gt MilkPak Service M
8. faulty materials or workmanship 4 The company will carry out repairs or replacement either through its own engineers or through approved contractors 5 This warranty is applicable only to the original purchaser of the unit or in the case of multiple purchases to the FIRST customer of the original purchaser at the FIRST site location 856018247 quality and conditions statutory or otherwise are excluded The Company gives no warranty as to fitness for purpose unless specifically stated in writing to the contrary The Company will not be liable for the cost or repairs to the unit arising from i Wilful damage or neglect ii Disregard of Company s installation and operating instructions including inadequate ventilation or blocking of air vents failure to provide a suitably rated and safe electrical supply or failure to install the unit on an even level surface iii Damage to exterior or interior casing of the unit due to but not limited to corrosion scratching denting etc iv Failure of light bulbs tubes or starter assemblies v Damage arising from dismantling transit or reinstallation The company will not be liable for the cost of repairs effected by third parties without the company s prior consent and approval No transfer of warranty is possible beyond the FIRST customer or the FIRST location 2006 IMI Cornelius Inc Mi ilkP ak S ervice M an ual 20 06 IM
9. information and it may not be reproduced in any way without permission from Cornelius Printed in the P R C Copyright 2006 All Rights Reserved IMI Cornelius Inc CGinelius gt MilkPak Service Manual TABLE OF CONTENTS RET OO BUG TION LOI CECI POIL peto 1 GEN BALINEOBMATION A 2 20 E 2 Bass M A 2 NST ON eee 3 LLL E 4 4 2 5 S 5 5 CONNECTING TO POWER nennen 6 MIA SANTA ELI Pon M LE 7 ILLUSTRATED an 8 856018247 2006 IMI Cornelius Inc MilkPak Service Manual 2006 IMI Cornelius Inc NOTE 856018247 MilkPak Service Manual INTRODUCTION Thank you for specifying Cornelius The Milkpak dispenser has been designed and engineered to high standards and if properly installed and maintained will provide a long and reliable working life You are strongly advised to read carefully the contents of this guide and then retain it for future reference Please remember the warranty can be invalidated by unauthorised tampering and all service or repairs must be carried out by qualified engineers trained to Cornelius stan dards of competence Please read the warranty carefully and note the exclusions listed Should any claims become necessary make them through the Cornelius Service Centre on 44 114 285 2673 A warranty and customer questionn
Download Pdf Manuals
Related Search
Related Contents
PA-860(J) MANUAL September, 2001 RAEGuard LEL - RAE Systems Offboard Navigation Copyright © All rights reserved.
Failed to retrieve file