Home

Troubleshooting Service Manual

image

Contents

1. e f normal communication between the gateway and the AC module is established close all the circuit breakers except for that of the gateway and the AC module Disconnect the gateway from the AC module and re install it indoors e Verify that the connection between the gateway and AC module is maintained after the second installation The correct number of AC modules should now be visible from the app e Turn on one of the circuit breakers and wait 10 to 15 minutes Scan for the AC modules through the app If successful turn on another circuit breaker and scan for the AC modules Repeat until all circuit breakers are back on If you encounter an error while scanning the last circuit breaker is interfering with the communication 17 3 1 7 Connecting the Gateway to a Remote Router If the gateway cannot detect the installed AC modules it is recommended to move the gateway near the distribution panel for more reliable communication To do so the gateway needs to be connected to a remote router via PLC Bridge as illustrated below Power Line Adapter Broadband router PLC Bridge Server Power Line Adapter M 1 Connect the AC adapter from Power Port 12V 1A of the gateway to a dedicated 120VAC outlet 2 Connect the PLC cable from PLC IN Port of the gateway to a dedicated 120VAC outlet 8 Connect one of the power line adapters from the LAN Port of the gateway to a 120VAC outlet 4 C
2. e The built in power line communication module is powered through the micro inverter Depending on the level of solar power generation the communication module might not receive sufficient power to communicate normally with the gateway Refresh the app during a different time e Communication errors can arise from the use of certain household devices Please try again after powering off the devices suspected of causing the problem If the error persists please refer to 3 1 1 Factors that Affect Power Line Communication 16 3 1 6 Checking for Interferences to the Power Line Communication e f there is still a problem with the connection between the gateway and the AC module it is necessary to check the factors causing interference e First connect the gateway directly to the AC module This will eliminate any potential interference caused by other devices normal communication should be achieved and the AC modules should be detectable by the smart phone app If the AC modules are still not detected on the app there could be a communication problem between the smart phone tablet and the gateway If you suspect that there is a problem with the gateway please request for a replacement unit It is recommended to install the gateway as illustrated in the figure below to prevent communication interferences PV Rack AC Module Trunk Cable gt Transition Cable AC Junction Box BR Equipment Es SN Grounding E General AC Conductor
3. 11 04 am 48 D1 8E 00 02 44 High 2 AC module ID AC Frequency Jul 4 2014 TUE 00 02 11 04 RA 48 D1 8E 00 02 44 Changing Too Fast 48 D1 8E 00 02 44 AC b ad 8 Message type Jul 4 2014 48 D1 8E 00 02 44 AC Frequency 11 04 am Low Jul 4 2014 11 04 am MODE ODDO DC Voltage 48 D1 8E 00 02 44 High Jul 4 2014 11 04 am WIDE DC Current 48 D1 8E 00 02 44 High Jul 4 2014 11 04 am AC Current 48 D1 8E 00 02 44 High Jul 4 2014 Tq DE dWna Inverter 11 04 am 48 D1 8E 00 02 44 z Failure Jul 4 2014 Temperature C3 T2 Ex Web Array View Screen amp Full System Gateways SELECT v AC Modules oa Array View Graph View Reports Events E Lifetime 08 04 2014 O mum 12 kh Energy Wh E Today E Past 7 Days E Month to Date E Year to Date 1 Cu p ustom Range 17 kwt 06 kwHhB28 kwi 30 eta e 83 kWhi7il kK Whes0 kKWhe02 k ILLE ae ris kw 84 kwhe4e kWhi397 kwheo7 kw 160 kwhi547 kWhB09 kwhae4 kw IT kW S22 kwh64i kwh630 kwh 37 kwheso kwi a v Q 321 0 MWh PeakPower 525 W Latest Power 70 7 W at 07 30 2014 19 45 oii 30 2014 19 45 Full System Taday Energy Past 7 Days Month to Date Lifetime O Wh 136 kWh O Wh 21 0 MWh 1 Select monitoring levels ex Full System by Gateway or individual AC Module 2 Set the monitoring period Today Past 7 Days Month etc 8 Installer scan zoom in or out of the screen 4 If the module is red maintenance is r
4. refer to the Troubleshooting Guide Details OK App Message Screen Web Event Screen e Check if there other any other alerts from the app e Check the system voltage Inquire to the power company after closing the circuit breaker Notice 4 5 AC Frequency High Low e Occurs if system voltage is lower or higher than the operational threshold It is usually caused by a problem with the energy company It may be a temporary problem and is automatically corrected by the energy company If the problem persists check the following 59 3 to 60 5Hz 57 to 60 5Hz Ex AC Frequency Low AC Frequency is the frequency at which voltage varies on the utility grid AC Frequency Issue Details The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 1 devices show more Alert Notice started on 2014 09 02 09 03 03 ended on 2014 09 02 09 19 15 coming from the utility is too low than allowed And this events are usually transient and selfcorrecting by the utility No action is required unless the condition persists If the condition persists refer to the Troubleshooting Guide Duration AC Frequency is the frequency at which voltage varies on the utility grid AC Frequency coming from the utility is too low than allowed Details And this events are usually transient and selfcorrecting by the utility No action is
5. SEPIUS Delete condition Check PLC LED It should turn red 2 Press the Back button Wait for a minute and check that the PLC LED has changed green Then press MAC Address List and check if the Dobos additional AC modules have been listed X If you can t check the additional AC modules connect the gateway to another outlet near the distribution panel and search for the unlisted AC modules 9 Press Registration button to finish 48 D1 8E 00 02 14 Delete 48 D1 8E 00 02 1F Delete 48 D1 8E 00 01 F3 Delete Enc Box LGElectronics Grour ange Add Import Expo 3 1 10 Changing the EnerBox If the EnerBox is not working correctly follow steps below to troubleshoot Mac Address List Registration 1 After connecting a new EnerBox enter the serial number of the failed EnerBox on the blank and press EnerBox Group change button 2 Compare MAC addresses listed in App and web server 48 D1 8E 40 00 53 Delete 9 If matching press Registration button to finish MAC Address 48 D1 8E 00 02 14 Delete 48 D1 8E 00 02 1F Delete 48 D1 8E 00 02 AB Delete 48 D1 8E 00 01 F3 Delete ex 1121408000322 gorse Add Import Export 3 1 11 Registering a Replacement AC Module to the Gateway Add Mac Address List MAC Address 48 D1 8E 00 02 14 48 D1 8E 40 00 53 48 D1 8E 00 02 1F 48 D1 8E 00 02 AB 48 D1 8E 00 01 F3 LGElectronics Import Registration Delete Delete Delete Delete
6. Voltage 300V Connector Max Current 20A TC ER sunlight resistant 600V UO e Max Voltage Cable Max Current 18AWG 300V Size Max Voltage Connector Max Current Certification UL9703 UL6703A On gt lt O D C1 Dimensions 400 mm 95 75 inch 31 5 mm 1 24 inch 53 mm 2 09 inch 122 mm 4 80 inch 1 200 mm 66 mm 47 24 inch 2 60 inch Table of Contents Product Specifications 1 Safety 2 Messages and Alerts 1 1 APP Messages Notice 1 and 2 AC Voltage High Low Notice 3 AC Frequency Changing Too Fast Notice 4 5 AC Frequency High Low Error 1 DC Voltage High Error 2 DC Current High Error 3 AC Current High Error 4 Inverter Failure Error 5 Temperature Protection Alert GFDI 3 Gateway and Communication Issues 3 1 Power Line Communication Issues 3 1 1 Factors that Affect Power Line Communication 3 1 2 Cautions during Gateway Installation 3 1 3 Problems Checking AC Module through the Smartphone App 3 1 4 Discrepancy of Installed AC Module Quantity on Smartphone App 3 1 5 Number of Registered AC Modules Fluctuating on Smartphone App 3 1 6 Checking for Interferences to the Power Line Communication 3 1 7 Connecting the Gateway to a Remote Router 3 1 8 Solving Connection Issues in the Gateway 3 1 9 Registering Additional AC Modules to the Gateway 3 1 10 Changing the EnerBox 3 1 11 Registering a Replacement AC Module to the Gat
7. operation will automatically be stopped 40 90 C 40 194 F Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 1 devices show more Alert Error Duration started on 2014 09 03 01 27 20 ended on 2014 09 03 01 43 35 Temperature from the AC Module Inverter is too hot than allowed And AC Module doesn t generate to protect itself This condition usually clears without intervention If the condition persists refer to the Troubleshooting Guide Temperature from the AC Module Inverter is too hot than allowed And AC Module doesn t generate to protect itself Details This condition usually clears without intervention If the condition persists refer to the Troubleshooting Guide OK App Message Screen Web Event Screen e Check that the operational ambient temperature is within the operational range If the ambient temperature is above 65 C 145 F the internal temperature of the micro inverter may exceed 90 C 194 F e Operation will resume automatically when the ambient temperature returns within the operational range Alert GFDI e Occurs if the system current leakage exceeds the limit Ex GFDI Screen Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 1
8. Delete EnerBox Group change Export If you need toexchange an AC module follow the steps below 1 Enter LGElectronics initial password on the blank box in the figure and press the EnerBox Group chage button to return the gateway to the initial condition Check that the PLC LED has turned red 2 Press Back button Wait for a minute and check that PLC LED is now turned to green Then press MAC Address List and check if the additional AC modules have been listed X If you can t see the additional AC modules connect the gateway to another outlet near the distribution panel and search for the unlisted AC modules 83 Press Delete button to delete the exchanging AC module MAC address 4 Press Registration button to finish 3 1 12 Relocating a Gateway with Completed AC Module Registration 20 48 D1 8E 00 02 6F 48 D1 8E 00 02 79 48 D1 8E 00 02 52 48 D1 8E 00 02 AC 48 D1 8E 00 02 BE 48 D1 8E 00 02 81 48 D1 8E 00 0277F 48 D1 8E 00 02 94 48 D1 8E 00 02 66 48 D1 8E 00 02 80 48 D1 8E 00 02 AE 48 D1 8E 00 02 A1 48 D1 8E 00 02 5F 48 D1 8E 00 02 87 48 D1 8E 00 02 9B 48 D1 8E 00 02 C4 48 D1 8E 00 02 41 48 D1 8E 00 02 98 48 D1 8E 00 02 B3 48 D1 8E 00 02 63 48 D1 8E 00 02 B5 48 D1 8E 00 02 6B 48 D1 8E 00 02 91 AC Module Status 27 23 Start up Start up Start up Start up Start up Start up Start up Start up Start up Start up Start up Start up Start up Start u
9. required unless the condition persists If the condition persists refer to the Troubleshooting Guide App Message Screen Web Event Screen e f you receive a message regarding low AC Voltage please check the circuit breaker e Problem may occur due to instability of the utility service 11 Error 1 DC Voltage High e Occurs if the AC module DC input voltage is higher than 50V 20 to 45 VDC Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information AC Frequency is the frequency at which voltage varies on the utility grid AC Frequency Affected Devices 1 devices show more Alert Error started on 2014 09 03 05 16 59 coming from the utility is too low than allowed E And this events are usually transient and selfcorrecting by the utility No action is required unless the condition persists lf the condition persists refer to the Troubleshooting Guide Duration DC Input voltage from the AC Module is too high than allowed If the condition persists refer to the Troubleshooting Guide Details App Message Screen Web Event Screen e Check for possible damages in the module and microinverter e f problem persists request for a replacement AC module Error 2 DC Current High e Occurs if the AC module input current is higher than the limit 12 ADC Ex DC Current High Screen AC Frequency is the f
10. voltage and the voltage setting in the installation app e Check that the permissible current of the circuit breaker is 20A e Check if the cables are for outdoor usage e Check the size of the cables If the size of the cables is smaller than 12AWG the flowing current in cables may be limited and the voltage may rise 10 Notice 3 AC Frequency Changing Too Fast Occurs if system voltage is lower or higher than the operational threshold It is usually caused by a problem with the energy company It may be a temporary problem and is automatically corrected by the energy company If the problem persists check the following Ex Frequency Changing Too Fast Screen Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information AC Frequency is the frequency at which Affected Devices 1 devices show more Alert Notice started on 2014 09 02 22 27 05 Duration Snded on 2014 09 02 22 43 19 voltage varies on the utility grid This value is changing more rapidly than allowed And this events are usually transient and selfcorrecting by the utility If the condition persists refer to the Troubleshooting Guide AC Frequency is the frequency at which voltage varies on the utility grid This value is changing more rapidly than allowed And this events are usually transient and selfcorrecting by the utility If the condition persists
11. Perfect AC Module The Difference is in the Detail Troubleshooting Guide LGxxxA1C B3 Product Specifications AC module DC Input 295 W 300W 305W Power 39 7 V 39 8 V 40 0 V Voltage Max Power Point 31 8 V 32 0 V 32 1 V Short Circuit 9 85 A 9 98 A 10 10 A Current Max Power Point 9 28 A 9 40 A 9 52 A Relative Reduction lt 2 0 Efficienc k Note Relative efficiency reduction in respect to irradiance Note Rated electrical characteristics are within 10 percent of above figures PV module was measured at STC Standard Test Condition Irradiation 1 000W m2 Cell temp 77 F 25 C 1 5AM AC Output AC Continuous 280W DC Module 295W 285W DC Module Power 300W 290W DC Module 305W Inverter Rated Continuous 305W 300W Voltage 240V 211 264 V 208V 187 229V 1 274 1 44A Current Max Fault Current 77A Bi 60 Hz 59 3 60 5 Hz Efficiency Extended 57 0 Hz 60 5 Hz Power Factor gt 0 95 CEC Weighted Efficiency California Energy Commission Max Number of AC Modules 12 ea 1 Pmax AC Max Input DC Power x CEC Efficiency Protection Ground Fault Detection and Interrupt GFDI Applied 2A CAUTION FOR CONTINUED PROTECTION AGAINST THE RISK OF FIRE REPLACE ONLY WITH SAME TYPE AND RATING OF FUSE Over Current Protection Device OCPD 20A 96 5 AC module Mechanical Data Micro Inverter Model Utility Interactive 40 65 C 40 145 F Operating Temperatur
12. devices show more j j Alert Alert Description Duration started on 2014 09 02 07 07 41 ended on 2014 09 02 08 13 11 Leakage current from the System is too high Details If the condition persists refer to the Leakage current from the System is too high Troubleshooting Guide Check the system ground OK App Message Screen Web Event Screen e Check for other error messages In case of a GFDI error the system will automatically reset within 1 minute e f problem persists check all connections Check that the wirings status is ok The insulators or jackets of the cables may be worn out or cut What is GFDI Ground Fault Detector Interrupter Ground fault is when currents flowing through the cable leak through an exposed conductor and touches the ground The GFDI Ground Fault Detector Interrupter function detects events of ground fault and automatically stops operation of the AC module 3 Gateway and Communication Issues 3 1 Power Line Communication Issues e The micro inverter has a built in power line communication module to support communication with the gateway The gateway includes the same module to communicate with the microinverter LG AC module monitoring system is designed to automatically achieve power line communication without additional configuration However the gateway and microinverter are commonly connected to the same power source in a home or building As a result other devices can affect t
13. e internal 40 90 C 40 194 F 40 90 C 40 194 F Certification UL 1703 IEC 61215 Ed 2 IEC 61730 Safety Class ll CE ISO9001 UL1741 IEEE1547 CSA 22 2 No 107 1 01 FCC Part 15 Class B Dimension Unit mm in 1000 39 37 Size of Short Side Cross sectional Drawings 2 5 x 4 0 960 37 80 5 0 x 10 Drain Holes 4ea Distance between Mounting amp Grounding Holes Cable Fixing Holes 4ea 7 107 0 T aD x 4 0 Drain ee m f ZS FE gt A l yy 1g 64 35 Grounding Holes 12ea ees 7 j D Al e W tos Yap Mounding Holes 8ea N 35 1 35 N 22 0 87 Short Side Frame 1070 40 1040 40 94 Distance between Mounting Holes 1640 64 57 Size of Long Side 900 35 43 Distance between Mounting Holes 357 Isao 9g44 37 17 28 l 10 Long side frame i 3 0 14 57 300 11 81 cy 9o 9 I f Aala Ft Response to Abnormal Conditions IEEE 1547 Default V gt 144V lt 0 16 lt 0 016 Hawaii mode TOV requenc Note 1 This test is performed in nominal conditions except for test parameter Note 2 After clearing if grid returns to the normal state it takes up to 5 minutes for operation of AC module Dedicated Cables TC ER sunlight resistant Max Voltage 600V Cable 20A Trunk Max Current Size 12AWG Max
14. equired Click the red module to see more details 5 Installer can check today s production information in this area System Energy Peak Power and Latest Power 8 Ex Web Event Screen LG EnerVu MetisTestGw3 ses ses Bim o DASHBOARD Full System Gateways SELECT M AC Modules SELECT SYSTEMS Array View Graph View Reports Events Current Issues Y Qo 1Devices Vfreq Over ACTIVATIONS Event Type Started 3 D A R ACCOUNT Jevices dd dd 1 Current Issues Provides the current conditions of the system 2 Event History Provides the event records for aspecified period 8 Click the device in the query results to check the Issue Details A pop up window will appear Issue Details Shows the following information Affected devices alert type alert duration and detailed descriptions Notice 1 and 2 AC Voltage High Low e It occurs when the system voltage is lower or higher than the operational threshold Due to a problem of the power company it can temporarily happen or and it is automatically adjusted by the power company If the problem persists check the followings Nominal Voltage 240 Volt AC Nominal Voltage 208 Volt AC 106 to 132 Vac 106 to 132 Vac 211 to 264 Vac 183 to 229 Vac AC Voltage coming from the utility has been too low than allowed This condition should correct itself No action is required unless the condition persists If the conditio
15. eway 3 1 12 Relocating a Gateway with Completed AC Module Registration 4 Gateway and Communication Issues 4 1 Network Configuration Troubleshooting 11 11 12 12 13 13 14 14 15 15 16 16 16 16 17 18 18 19 19 20 20 21 1 Safety Note and comply with the safety guidelines of this manual while handling AC modules Failure to comply may result in severe damage to the equipment and or fatal injuries 1 1 Safety Symbols Safety symbols are used to minimize loss and injury during handling and operation of the equipment specified in this manual PW Ned Failure to comply with the instructions may cause fatal injuries or immediate death Failure to comply with the instructions may cause severe injuries or death CAUTION Failure to comply with the instructions may cause injuries or damage to property Failure to comply with the instructions may cause severe injuries or immediate death by overvoltage Failure to comply with the instructions may cause injuries or damage to property by fire AC Module A DANGER To prevent the risk of electric shock stay away from current carrying terminals during operation And allow several minutes after the circuit breaker has been turned off It may be energized in the open position To prevent the risk of overvoltage do not disconnect the cable connector during operation To prevent the risk of burns do not touch metal parts during operation For safety
16. following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 1 devices show more Error started on 2014 09 03 00 54 50 ended on 2014 09 03 01 11 05 DC Output current from the AC Module is too high than allowed If the condition persists refer to the Troubleshooting Guide Web Event Screen e Check that proper cables are used for the system and that the AC connector is connected correctly Error 4 Inverter Failure e Occurs if AC module malfunctions Ex Inverter Failure Screen Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 1 devices show more LJ Description Alert started on 2014 08 31 13 30 56 Duration Details AC Module has been failure mode If the condition persists refer to the Troubleshooting Guide App Message Screen e Check for other messages e Problem may stem from instability of the system Error ended on 2014 08 31 14 02 58 AC Module has been failure mode If the condition persists refer to the Troubleshooting Guide Web Event Screen e Check that proper cables are used for the system and that the AC connector is connected correctly 13 Error 5 Temperature Protection e Occurs if the internal temperature of the inverter is outside of the operation range
17. he communication between the gateway and micro inverter and vice versa This interference can lead to communication issues 1 AC Module Power Communication e 2 Communication Smartphone Gateway Installation t Distribution Server board lt 3 Monitoring do Smartphone 3 1 1 Factors that Affect Power Line Communication e Power strips or surge protectors in the same circuit e UPS Uninterruptible Power Supply or Battery backup units in the same circuit e Lamp dimming switches e Power line communication based home networks or home automation devices e Sensor lamps e Battery Chargers Cell phone and laptop charger e AC Adapters Heavy rotating motors fans refrigerators freezers water pumps etc e Home Appliances including but not limited to washing machines and dryers vacuums hair dryers electric drills etc e Electricity powered insect repellants e Other electronic devices Please designate a power outlet for the sole use of the gateway 15 3 1 2 Cautions during Gateway Installation Power strips surge protectors and outlet adapters can interfere with power line communication Be sure to plug the gateway directly to a power outlet A lamp or light switch can contribute unwanted noise to the communication Be sure to dedicate a power outlet for the sole use of the gateway e Existing home appliances and other electronics can interfere w
18. ith the gateway s power line communication 3 1 3 Problems Checking AC Module through the Smartphone App e f AC modules registered to a gateway cannot be accessed through the smart phone app there is a communication problem between the gateway and AC module e This could be a problem with the current outlet Try to connect the gateway to a different outlet e Though the maximum communication distance range is 328 yds under optimal conditions it is recommended to install the gateway within 109 yds 100m of the AC modules e t is strongly recommended to have a dedicated outlet between the gateway and AC module Appliances and devices using the same outlet will disrupt communication 3 1 4 Discrepancy of Installed AC Module Quantity on Smart phone App e f the number of AC module on the app does not correctly reflect the number of installed modules it is a possibility that the AC modules are not fully operational due to insufficient power supply for communication After checking that energy is being generated in the modules try scanning for the missing modules on the app e Scan for the AC modules during the day when they are generating energy e f the error continues there is a problem with the communication connection Please refer to 3 1 1 Factors that Affect Power Line Communication 3 1 5 Number of Registered AC Modules Fluctuating on Smart phone App e The number of registered AC modules can change on the app for two reasons
19. n persists refer to the Troubleshooting Guide Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 17 devices show more Alert Notice started on 2014 09 02 22 27 05 Duration ended on 2014 09 03 00 38 26 AC Voltage coming from the utility has been too low than allowed This condition should correct itself No Details action is required unless the condition persists If the condition persists refer to the Troubleshooting Guide OK App Message Screen Web Event Screen e Check the voltage at terminals in the distribution panel sub panel AC junctionbox and transformer between the grid and the AC module system Otherwise the grid may be unstable or there may be a problem with the maximum capacity of the transformer There is also a possibility of short circuits arising between two conductors The below diagram illustrates an example of checking the voltages Voltage Measurement io rm x x 2 pole Determined according tc the total current An array of AC modules AC junction box Distribution panel e Check the wirings to see if the connection is ok The conductors in the cables may have been damaged or cut e Check if the connector connection is ok The connector may be broken or connected improperly e Check that there is not discrepancy between the real grid
20. o not drop the module modules must be gently handled and placed down For proper operation do not scratch the coating surface of the frame It may increase the corrosion of the frame e For proper operation do not concentrate sunlight on the module surface e Addition of holes in the frame or glass of the module may decrease the strength and integrity of the frame or glass e Do not remove warning labels e Store the module in its original package until installation OY Gateway e EnerBox warranty void if cover removed No serviceable parts inside Refer servicing to qualified personnel e To avoid communication interference do not connect the product to power strips surge protectors or surge protector embedded power strips It is recommended to directly connect the gateway to a120VAC outlet e Only certified installers should enter the installer mode PV system may malfunction e Set the grid configuration to best suit the installation area PV system may malfunction 2 Messages and Alerts The app shows real time status of the AC modules under AC Module Status and System Status as well as Array View and Events through the monitoring web server Please refer AC module System Installation Instruction and AC Module Web Server Manual for further details Ex App Messages Screen AC Module ID Event Jul 3 2014 ITEN AC Voltage 11 04 am 48 D1 8E 00 02 44 Low Jul 3 2014 11 04 am Jul eg 2014 1 Date Jul 4 2014 Nee TN
21. only qualified persons should service modules To prevent the risk of electric shock stay away from damaged module s Do not use module s with broken glass or torn backsheets e Damaged modules must be handled with proper safety equipment Failure to comply may result in serious bodily injury or death For proper operation make sure to use exclusively cables connectors and accessories provided by LG Electronics Parts that are not listed may cause critical danger For proper operation the AC Module shall be connected only to a dedicated branch circuit To prevent the risk of fire do not connect any device between the AC module and circuit breaker Circuit breaker may not work properly Before installation make sure to check that the area of location meets the required environment specified in Chapter 6 Product Specification Voltage frequency temperature number of AC modules overcurrent device e Use proper equipment connectors wires and buttresses for the installation of the module Failure to comply may result in product damage product failure and or bodily injury o reduce the risk of accidents do not install during inclement weather To prevent the risk of electric shock do not touch the glass surface or frame of the solar module after installation To prevent the risk of injury do not apply pressure on the module ex placing heavy objects or stepping on the module To prevent the risk of injury d
22. onnect the other power line adapter from a spare port on the broadband router to a 120VAC outlet 3 1 8 Solving Connection Issues in the Gateway If connection problems occur on the gateway please check the LED status located on the back of the gateway and follow the troubleshooting table below If the problem persists please turn off the system circuit breaker and contact the service center 1 888 865 3026 lg solar lge com LED status Troubleshooting AC Adapter may be incorrectly connected Power LED No Light Check the AC Adapter and outlet in use if power still does not come on contact your electricity provider for possible power grid problems GFDI ON Possible wiring problems within the system Red Turn off then on using the system circuit breaker and wait 10 minutes PLC ON Connection between AC cable and outlet or system and power grid may be interrupted Red Reconnect the AC cable if light does not change to green try other outlets Wireless LAN ON Possible problem with the wireless module inside the gateway Red Contact the service center 18 3 1 9 Registering Additional AC Modules to the Gateway If you hit the Registration button before listing all AC modules or you need to add the unlisted AC module follow steps below Mac Address List Registration MAC Address 1 Enter LGElectronics initial password on the blank box in figure and press EnerBoxGroupchage button toreturn the gateway to the initial
23. p Start up Start up Start up Start up Start up Start up Start up Start up Start up Start up After the EnerBox is connected to a 120VAC outlet of the new location enter into AC Module Status and check that all previously registered MAC addresses colors are shown in black x MAC address color is red Unreliable link detection If some MAC addresses colors are red the EnerBox must be connected to a different AC outlet 4 Gateway and Communication Issues 4 1 Network Configuration Troubleshooting Web Server Communication Errors e Check the LAN cable connection to the wired LAN port If necessary reconnect e Check the hub or router settings e Check the smart phone app settings e Check that the server IP and domain are listed correctly on the app Reset the power of the Gateway e Check that the network is stable with your service provider 21 Memo 22 Memo 23 Life s Good This document is subject to change without notice LG LG logo and Life s Good are trademarks of LG Electronics Inc worldwide Trademarks and intellectual properties of LG Electronics Inc are protected by international copyright laws
24. requency at which voltage varies on the utility grid AC Frequency Issue Details A The following provides a summary of the detected issue Please follow the recommended action or contact LG EnerVu for more information Affected Devices 1 devices show more Alert Error started on 2014 09 02 07 40 33 ended on 2014 09 02 08 13 11 coming from the utility is too low than allowed And this events are usually transient and selfcorrecting by the utility No action is required unless the condition persists If the condition persists refer to the Troubleshooting Duration DC Input current from the AC Module is too high than allowed If the condition persists refer to the Troubleshooting Guide Details App Message Screen Web Event Screen e Using a multimeter check the voltage of the input terminal e Check for other messages e f problem persists request for a replacement micro inverter 12 Error 3 AC Current High e Occurs if the AC module output current exceeds the operational threshold Nominal Voltage 240 Volt AC 1 27A AC Nominal Voltage 208 Volt AC 1 44A AC Ex AC Current High Screen Issue Details A Alert DC Input current from the AC Module is too high than allowed If the condition persists refer to the Troubleshooting Guide Duration Details OK App Message Screen e Check for other messages e Problem may stem from instability of the utility service The