1. GRINDMASTER CORPORATION INSTALLATION OPERATION AND SERVICE MANUAL Model BL 2P Model BA P Model BL 3PW INSTALLATION INSTRUCTIONS FILL BREWER TANK WITH WATER BEFORE CONNECTION TO POWER SUPPLV Place the decanter under brew basket raise top evaporation cover and pour three decanters of water through the top pour in opening Water should come through the brew basket as the third decanter of water drains out of the pour in basin Brewer is shipped with thermostat turned on full clockwise position Plug brewer into a dedicated grounded 120V 15A circuit Allow 10 15 minutes for water in tank to heat to brewing temperature Hot water mav drip from brew basket on initial thermal expansion of water in the tank This will not occur thereafter After water has reached brewing temperature thermostat will click off heating noise will stop and green readv light will be on pour 1 decanter 60 oz of water through pour in opening More than 1 decanter of water will flow into decanter below brew basket due to water expansion in tank Machine in now readv to use Pour 1 decanter of water through pour in opening to check for proper temperature setting with an accurate thermometer Take the temperature of this water at a point below the brew basket opening at the start of the brew cycle and when the decanter is half full Recommended temperature of the water is approximately 195 F In higher altitude locations 5 000 f
2. start brew cycle with empty container Refer to dripping step 1 If you still need help call an authorized dealer in your area or Grindmaster Corporation s Technical Service Department You can reach Technical Service at 502 425 4776 or 800 695 4500 USA and Canada only Monday Friday 8 00 AM 6 00 PM EST Please have the model and serial number ready so that accurate information can be given Prior authorization must be obtained from Grindmaster Corporation s Technical Service Department for all warranty claims Page 8 AMWe Pourover Brewer Manual COMPONENT REPLACEMENT INSTRUCTIONS A WARNING Disconnect power before servicing Risk of electric shock These steps apply to replacement of TANK TANK HEATER and HI LIMIT or MAIN THERMOSTAT Remove brewer lid Disconnect electrical connectors from upper warmer plate if applicable Remove pour in basin assembly receiving pan Disconnect electrical terminals and hoses as needed Remove front two screws mounting the tank Lift tank and lid completely out of tank Remove two rear screws mounting tank to tank lid Reverse steps 1 6 to reassemble new tank assembly N a O re Li THERMOSTAT HI LIMIT Disconnect wires to hi limit thermostat Remove two screws and remove thermostat Check continuity of the new hi limit thermostat before installing Screw down new t stat and reconnect wires Make sure the hi limit thermostat is securely mounted and that all electr
3. 20 Element Heating 1400W 120V 37 73027 Airpot Stopper 70818 Element Heating 2500W 240V 38 73028 Leg Support VA 73037 Inlet Tube Assemblv 39 73095 Bracket Tank 11 73032A Cover Tank w Bracket Thermostat 40 73000 Bracket Warmer 12 71147 Grommet Thermostat 41 73031 Panel Warmer Top BL 2P 13 61243 Grommet Inlet Tube 42 73004 Top Cover SS BL 2P 15 62238 Bracket Hi Limit 120V 43 73015 Panel Top Body BL 2P 16 73096 Thermostat Clip Lock 44 73017 Panel Back BL 2P 17 73036 Thermostat Regulating 45 73023 Panel Center SS BL 2P 20 05911 02K Brew Basket 46 73029 Panel Base Cover BL 2P 21 73059 Switch Warmer Lighted 120V 50 73011 Panel Spray Head Assy 73058 Switch Warmer Lighted 230V 51 73012 Rail Brew L H 22 62436 Ready Light Green 120V 52 73013 Rail Brew R H 61125 Ready Light Green 240V 53 73049 Plastic Jug 23 06491 Deflector Spray HD 55 73003 Top Cover SS BA P 24 06490 Nozzle SPR HD 56 73014 Panel Top Bodv BA P 25 07220 Nut Lock Palnut SPR HD 57 73016 Panel Back BA P 26 70341 Elbow Silicone 90 deg 58 73022 Panel Center SS BA P 27 71607 Panel Pour Over Lid 54 73021 Bracket Tank Base BA P 28 71529 Wire Hinge Pour Over Lid 56 73005 Decal Main Front BA P 29 73002 Plate Warmer 73006 Decal Main Front BL 2P 30 13029 Heater Warmer 120V 100W 73097 Decal Main Front BL 3PW 31 100523 T Stat 1 2 Manual Reset 59 73080 Panel Base Cover BL 3PW 62237 T Stat Hi Limit 120V 60 73099 Panel Top Bodv BL 3PW AMWe Pourover Brew
4. eet above sea level the thermostat mav have to be adjusted lower to prevent boiling COFFEE PREPARATION PROCEDURES N ZE aH Place filter into brew basket Put the proper amount of coffee into the filter 3 Slide the brew basket into holder 4 Place empty decanter on warmer located directly under the brew basket and turn corresponding warmer switch ON NOTE For airpots open airpot lid remove pump stem from airpot and place airpot opening directly under center hole in brew basket 5 Pour decanter of fresh water through pour in opening at top of brewer 6 Hot water will be delivered through the sprayhead This distributes the hot water evenly over the coffee bed within the brew basket The coffee will drain from brew basket into the container below 7 TURN OFF WARMER WHEN NOT IN USE Red light indicates warmer is ON Not for airpot brewers 8 Before brewing next pot remove brew basket from brew rails and dump filter into waste basket SPARE PARTS LIST Item No Part No Description Item No Part No Description 1 73035 Water Tank 32 100524 Bracket Hi Limit Thermostat 2 07327 Clamp Black 5 8 33 73008 Nut Slotted Hex size M20x1 50 3 05826 Tubing 3 8 x 5 8 Silicone 34 73010 Pan Receiving 4 61232 Plug 3 8 Barbed 35 73019 Access Panel 5 73057 Gasket Tank O Ring 36 73024 Base Cover Panel BA P 6 708
5. er Manual Page 3 WATER TANK ASSEMBLY Page 4 AMWe Pourover Brewer Manual BL 2P PART LIST Page 5 AMWe Pourover Brewer Manual BA P PART LIST AMW e Pourover Brewer Manual Page 6 BL 3PW PART LIST Page 7 AMWe Pourover Brewer Manual TROUBLESHOOTING GUIDE Problem Possible Source Check Solution No Hot Water 1 Tank heater 1 Check the voltage at the tank heater terminals Voltage should be 120VAC Check serial tag for proper voltage 1 A If correct voltage is present at the tank heater terminals and water is not being heated replace tank heater B If voltage is not present at tank heater terminals refer to step 2 C If incorrect voltage is present at tank heater terminals check voltage at outlet and switch and between switch and warmer 2 Hi limit thermostat 2 Check the voltage between the 2 A If voltage is present on incoming terminal on or main thermostat white wire on the tank heater the hi limit thermostat but not on the outgoing terminal and the incoming terminal terminal replace hi limit thermostat black wire on the hi limit B Check voltage between black and white wire thermostat then the outgoing on receptacle If voltage is not present check black wire terminal on the hi limit outlet or circuit breaker thermostat C If voltage is not present on incoming terminal of hi limit thermostat replace main thermo
6. hat are binding to Grindmaster Corporation Neither written nor oral statements by such individuals establish warranties and thus should not be relied upon This will establish your warranty rights The purchaser s redress against Grindmaster Corporation for the breach of any obligation arising from the sale of this equipment whether derived from warranty or elsewhere shall be limited to repair replacement or refund at Grindmaster Corporation s discretion Grindmaster Corporation 4003 Collins Lane A Louisville KY 40245 USA e GRINDMASTER 502 425 4776 CORPORATION 800 695 4500 USA 8 Canada only FAX 502 425 4664 WWW grindmaster com Grindmaster Corporation 2004 0805 Form f BW 317 02 PRINTED IN USA
7. ical connections are tight and isolated m MAIN THERMOSTAT 1 Disconnect wires and remove tank and tank lid assembly 2 Remove two rear screws mounting tank to tank lid 3 Remove screws which secure thermostat to tank lid 4 Loosen thumb nut securing capillary bulb 5 Remove grommet from top of tank lid by pressing up with thumb and pulling capillary bulb out through hole 6 Reverse steps 1 5 to reassemble new tank assembly TANK HEATING ELEMENT 1 Disconnect wires and remove tank and tank lid assembly 2 Remove two rear screws mounting tank to tank lid 3 Loosen thumb nut securing capillary bulb and remove bracket 4 Remove two brass nuts and remove element 5 Install new element and washers with nuts secured tightly 6 Inspect tank lid gasket and replace if necessary 7 Reverse steps 1 3 to reassemble WARMER ELEMENT 1 Remove retaining screws from warmer plate 2 Lift plate and disconnect leads 3 Remove nuts and washers holding retaining plate and warmer element to plate 4 Reverse steps 1 3 to reassemble AMWe Pourover Brewer Manual Page 9 Page 10 AMWe Pourover Brewer Manual AMWe Pourover Brewer Manual Page 11 Grindmaster Corporation Product Warranty for USA Effective January 1 2003 New Machines that have been manufactured by or for Grindmaster Corporation and all parts thereof are conditionally warranted to the original user by Grindmaster Corporation to be free from defects in material a
8. nd workmanship existing at the time of manufacture and appearing during the stated warranty period under normal use and service as follows All Equipment including AMW unless specified otherwise below 2 years parts and 1 year labor Crathco barrel style freezers 1 year parts and 90 days labor Compressors on refrigerated dispensers 5 years parts and 1 year labor Compressors and evaporator assemblies on Crathco barrel style freezers 5 years parts and 90 days labor Compressors on granita machines distributed by Grindmaster Corporation 2 years parts 1 year labor Micro Controller based boards except granita and Crathco barrel style freezers 4 years parts and 1 year labor Grinding burrs on coffee grinding eguipment manufactured by Grindmaster Corporation does not include espresso grinders or Mahlkoenig grinders 4 years parts or 30 000 pounds of coffee whichever comes first and 1 year labor Grindmaster Accessories except glass decanters 90 days parts only e B Series and Space Saver Urns 2 years parts and 2 years labor e Espresso Machines and Distributed Products Espresso Grinders Mahlkoenig Grinders 1 year parts and 1 year labor e Restoration Station refurbished equipment 6 months parts 90 days labor on work performed During these warranty periods Grindmaster Corporation will at its option and after inspection repair or replace a defective unit with no charge for parts or bench labor during the applicable parts or labor warrant
9. of the unit e Upon request by Grindmaster Corporation some warranty parts including but not limited to motors compressors micro controlled based boards gear motors and burrs shall be shipped prepaid to the Grindmaster Factory Service Center designated in the RGA confirmation Upon receipt Grindmaster Corporation will inspect parts to verify warranty claim is valid Replacement parts will be billed out when shipped and then credited on return of a part that is proven to be a valid warranty claim upon inspection by Grindmaster Corporation Warranty labor will not be paid until warranty claim parts are received and validated by Grindmaster Corporation e The buyer shall give prompt notice to Grindmaster Corporation and must obtain prior authorization from Grindmaster Corporation for any claim to be made under said warranty via telephone at 800 695 4500 or writing to PO Box 35020 Louisville KY 40232 5020 e Upon request by Grindmaster Corporation the defective equipment shall be shipped prepaid to the Grindmaster Factory Service Center designated in the RGA confirmation or if requested by Grindmaster Corporation to an authorized Grindmaster service location e No field outside or service station work is covered by this warranty without prior authorization by the Grindmaster Service Department The dealers distributors employees and agents of Grindmaster Corporation are not authorized to modify this warranty or to add warranties t
10. stat Steaming or 1 Main thermostat 1 Thermostat contact stuck or out of 1 A Adjust thermostat to lower temperature Spitting Around calibration setting Funnel B Thermostat should be calibrated or replaced 2 High altitude 2 For altitude above 5 000 feet Dripping 1 Not siphoning 1 Water should flow from sprayhead 1 A Clean sprayhead holes properly freely B Check tightness of sprayhead tube C Check brass elbow in tank for debris Dry Coffee 1 Filters 1 Are correct filters being used 1 Use correct filter Remaining on 2 Not siphoning 2 Refer to dripping step 1 2 Refer to dripping step 1 Brew Basket properly 3 Improper loading of 3 Filter and coffee in brew basket 3 Filter should be centered in brew basket and brew basket coffee bed should be level Warmer Station 1 Warmer defective 1 Voltage at warmer terminals should 1 If voltage is present on terminals but warmer is be 120 VAC not heating replace warmer 2 Warmer On Off 2 If voltage is not present on warmer 2 If switch does not make and break continuity switch terminals check continuity of switch when turned on and off replace switch 3 Bad harness 3 Check connections between harness 3 All connections should be tight Overflowing Receiving container not completely empty at start of brew cycle 2 Not siphoning properly 2 Operating instructions Refer to dripping step 1 Always
11. y period respectively Grindmaster Corporation s obligation under these warranty periods shall be limited to repairing or replacing any part of said dispenser excluding plastic parts rubber parts light bulbs or normal wear items which proves defective within the warranty period These warranty periods run from the date of installation proof of installation date reguired or 6 months following the date of shipment from the Grindmaster Corporation factory whichever comes first Bench labor does not include the service agent s travel time or cost of shipping to and from the service station or factory This warranty is subject to the following conditions terms and exclusions for a detailed list see Warranty Addendum e Warranty does not apply to machines or any part thereof which have been subject to any accident abuse misuse neglect alteration use on incorrect voltage improper ventilation damage caused in transit improper installation or operation improper maintenance or repair normal wear items plastic or rubber parts poor water conditions machine adjustments temporary non functioning conditions fire flood or acts of God e Warranty is in lieu of all other warranties expressed or implied In no event shall Grindmaster Corporation be liable for conseguential or incidental damages e The model and serial number of the unit shown on the serial plate shall be supplied to the service station or factory along with the defective parts

Download Pdf Manuals

image

Related Search

Manual manual manualslib manual car manual timesheet manual transmission manuale digitale manually meaning manual wheelchair manual arts high school manually update your device drivers windows manual labor manual definition manual for courts martial manual muscle testing manual muscle testing grades manually register devices with autopilot manual keyboard manual blood pressure cuff manualidades manual lawn mower manual transfer switch manual transmission cars for sale manual therapy cpt code manual libs manual autopilot enrollment