MicroLux® DLX Camera System NTSC & PAL
Contents
1. MicroLux DLX Camera System NTSC amp PAL ta Bii 4 Operation and Service Manual N Table of Contents Table of Symbols scisso inariiraort p 3 General Warnings p 3 MicroLux DLX Camera Control Unit CCU Assembly p 4 MicroLux DLX Camera Overview Indication for USE p 5 Inspection Before Use eeeeees p 5 Installation of CCU to Floorstand optional p 6 Set up Before Use cece cece eeeeeenee ene p 6 Camera Spot Alignment cece cece eeeeeeeees p 6 Connection INStructions eee eee ee eeeenees pp 9 White Balance i p 10 TrOUDIESNOOTING p 10 Cleaning sresssona reti rs e anac p 10 MicroLux DLX Camera Specifications p 11 Ordering EQUIPMENT eee eee cece eeteeteeeeeees p 11 Limited Warranty eee eeeeeseee eee eeeees p 12 Repair and Return Instructions p 12 N Table of Symbols On Off button Composite video PXO Ordinary protection against ingress P Alternating current of fluids CSA Indicates this product is listed by CSA International as certified White Balance N General Warnings Warning Caution AN Read Operation and Service Manual before use Type BF Equipment e The user should carefully study this Operation a
2. or damaged during shipment This warranty is non transferable unless authorized in writing by Luxtec Luxtec reserves the right to make design changes on its products without liability to incorporate said change in Luxtec products previously designed or sold Upon receipt of the product it should be carefully inspected If any defect is discovered notification must immediately be given to the manufacturer and distributor N Limited Warranty Contact your local Luxtec distributor for Return Authorization This device must be clean when returned Luxtec reserves the right to return un repaired any equipment that is contaminated with blood or other organic material Warranty Service and Repair To obtain service under warranty or return product for repair the customer should contact your local Luxtec distributor or call Luxtec Customer Service at 1 800 325 8966 USA or 1 508 835 9700 Surgical 99 Hartwell Street West Boylston MA 01583 USA Telephone 800 325 8966 USA amp Canada or 1 508 835 9700 Fax 1 508 835 9976 email CustSvcLuxtec integra LS com www integra surgical com Integra Surgical and the Integra wave logo are trademarks of Integra LifeSciences Corporation Luxtec is a registered trademark of Integra LifeSciences Corporation or its subsidiaries P N 850328 Rev E
3. screws See Figure 4 3 Mount CCU to the bracket using a Phillips Figure 3 screwdriver See Figure 5 Figure 5 Set up Sequence Power must be off Align the red dot on the camera head connector with the red dot shown on the front of the CCU Push the camera head connector fully into the CCU Plug the AC power cord into the back of the CCU Connect the video cables from the back of the CCU to a monitor printer recording device etc See Connection Instructions e Push on 0 button to activate the camera green light on the front of CCU should be on CAUTION Carefully align the red dot on the camera head connector with the red dot shown on the front of the CCU See Figure 6 Connection Instructions Back View Recording Device Monitor Step 1 Step 2 Step 3 AC Power Connection Video Connection Recording Device to CCU to Recording Device Monitor Connection Front View Step 4 Step 5 Camera head connection Power on via camera cable Step 1 AC Power Connection to the Camera Control Unit CCU CAUTION DO NOT plug in the power supply to the wall outlet yet DO NOT TURN THE POWER ON YET Step 2 Camera Control Unit connection to a Recording Device The CCU has both S video and BNC video connections Connect the video cable s from the CCU to the VIDEO IN of the recording device If both S video and BNC video cables are used make sure they do not connect to the VID
4. 28 grams Weight complete headlight assembly includes camera head headband headlight and two feet of cable 230 grams 8 oz Dimensions control unit ii 4 6 W 117mm x 2 33 H 59mm x 5 77 D 147mm Weight of Control unit 700 grams 25 oz Power to COU ina 100 240VAC 10 Power consumption s ssssssssnesreesrerresrrrerrrsrrrerren 25W max 5w nominal Image Sensor siii Y Inch CCD OUIPUE core Seserenaveenewenoseseecerecesenee composite video and S Video in either NTSC or PAL PRE SOMIMOM iii iris NTSC 768 lines H x 494 pixels V PAL 752 lines H x 582 pixels V CIASSINCAlION arida Type BF Class II Electrical Safety i IEC 60601 1 UL 60601 1 CAN CSA C22 2 NO 601 1 M90 IEC 60601 2 18 Water Ingress Rating i IEC 60529 IPX0 Electromagnetic Compatibility IEC 60601 1 2 Class A IEC 61000 3 2 IEC 61000 3 3 Recommended Conditions Operating Temperature 5 to 40 C and 10 to 85 relative humidity non condensing Storage Temperature 0 to 50 C and 10 to 85 relative humidity non condensing N Ordering Equipment To place an order contact your local Luxtec distributor or call Luxtec customer service at 1 800 325 8966 USA or 1 508 835 9700 to identify your local distributor MicroLux DLX Camera System 003085NTSC Includes NTSC Camera Contro
5. EO IN of the same recording device Step 3 Recording Device connection to a monitor It is only necessary to connect one video cable to the monitor If both the S Video and BNC cables are connected to a single monitor please ensure that one is connected to line A and the other to line B If using more than one monitor or recording device you can use both S Video and BNC cables If the recording device is not used BNC Connection from the camera to the monitor If you used the BNC cable at the rear of the camera connect using the BNC cable to the rear of the monitor and lock the BNC connector as shown LINE B m VIDEO A BNC connection to Line A VIDEO IN OR If the recording device is not used S Video Connection from the camera to the monitor To connect using the S Video cable to rear of the monitor line up the pins and select the Y C INPUT Y C INPUT S Video cable connector pin orientation S Video cable connected to the Y C INPUT S video connection Infrequently you will need to use the RCA plug to connect to a monitor or recording device In order to do this connect the RCA plug adapter to the end of the BNC cable as shown below Step 4 Camera head connection to the CCU Carefully align the red dot on the camera head connector with the red dot shown on the front of the CCU Step 5 Power ON 1 Turn on the monitor recording device and or printer 2 Select Line A or Line B on the monitor 3 Put
6. N MicroLux DLX Camera Control Unit Assembly d D A LU TEC Front View Rear View 1 POWER switch Turns the camera control unit CCU on and off 2 POWER indicator Illuminates when the power is turned on 3 CAMERA head connector Connects the camera head to the CCU 4 WB switch Activates the white balance function 5 AC power Accepts a standard AC power cord 6 S Video connector Connects CCU to S Video input of a monitor recording device printer etc 7 BNC VIDEO connector Connects to video input of a monitor recording device printer etc Can be used at the same time as the S Video connector N MicroLux DLX Camera Overview Indication for Use The Luxtec video camera is mounted on a headlight to provide visualization of a wound or surgical site See Figure 1 Inspection Before Use The MicroLux DLX Camera system includes a camera head mounted on the headlight module a headlight cable a headband or sweatband video connecting cables and adapters and a camera control unit CCU Figure 2 Check to make sure you have all cables adapters and camera parts Please verify that all components have been received undamaged Figure 1 Installation to Floor Stand Optional 1 Using a 5 64 Allen or Phillips screwdriver remove cable bracket on left side of the floorstand and keep the screws handy See Figure 3 e g 2 Mount the bracket to the floorstand using the ili existing
7. l Unit CCU and Camera head mounted on the UltraLite Plus Headlight System 003085PAL Includes PAL Camera Control Unit CCU and Camera head mounted on the UltraLite Plus Headlight System Reordering parts 001270BIF Headband for UltraLite 2 bifurcated cable 001290BIF Sweatband for UltraLite 2 bifurcated cable 0029009 UltraLite 2 cable bifurcated 9 275cm 005331LX Cable clip kit package of 4 Recommended Light Sources 9300XDPTT 300 Watt Xenon Dual Port Light Source 9300XSPT 300 Watt Xenon Single Port Light Source OOLX300T 300 Watt Xenon Light Source with turret N Limited Warranty Luxtec warrants that the equipment manufactured by Luxtec shall be free from defects in material and workmanship under normal use and service for a period of one 1 year from the date of purchase from Luxtec Luxtec s sole and exclusive liability under the warranty shall be at Luxtec s option either to repair any component which fails during the warranty period due to any defect in workmanship or material F O B factory if 1 Customer promptly reports such defect to Luxtec in writing 2 If requested by Luxtec customer returns equipment to Luxtec with shipping charges and 3 Upon inspection Luxtec finds the equipment to be defective This warranty is contingent upon normal and proper use of the equipment It does not cover equipment modified without the written approval of Luxtec subjected to unusual physical or electrical stress
8. nd Service Manual before using this equipment in the clinical environment Instructions should be followed explicitly with special attention given to warnings controls and user specifications The Manual should be available to the appropriate personnel e The user of this product should be thoroughly familiar and trained in the assembly use and care of this product e Follow the instructions and restrictions in the operating manuals of other manufacturer s equipment when they are used in conjunction with this product e Before every procedure carefully inspect the Camera to ensure it has been properly maintained and cleaned and that it is fully functional DO NOT use if inspection reveals any damage such as cable cuts or loose connectors e To reduce the risk of fire and electric shock do not expose electrical equipment to moisture When cleaning do not immerse the camera head or any other electrical device in liquid Do not use or store liquids on or above the Camera All electrical equipment must be used with approved hospital grade power cords and power plugs inserted properly into grounded AC power outlets e Electric shock hazard If unit is not functioning properly DO NOT OPEN Please refer to the Repair and Return Section of this Manual for instructions e Do not use in the presence of flammable anesthetics liquids vapors gases or dusts e Use care not to point any light guide directly at the eye while operating this system
9. nitor settings not correct Intermediate component recording device printer connection not correct Poor image quality Components not connected properly Dirty Camera lens obstruction YBa damaged camera Video standard incompatibility NTSC PAL Image not centered on monitor Illumination spot not vertically cen tered on video image Colors not correct White balance is not correct Black and white image S video cable connection is loose Dim image Insufficient light at surgical site N Cleaning Action Turn power on Connect camera head cable to front of CCU with power OFF Plug CCU power cord into outlet Turn monitor on Consult monitor manufacturer s guide Consult connection diagram in this manual Consult connection diagram in this manual Refer to cleaning instructions Contact your Luxtec distributor Consult components manufacturers Contact your Luxtec distributor Follow white balance instructions in this manual to reset Secure S Video cable connections Increase light output per light source user instructions The Camera can be wiped down using 70 isopropyl alcohol Be sure to unplug the power cord before cleaning Allow 5 minutes for alcohol to evaporate before reconnecting to power a N Specifications Dimensions camera head only 0 43 W 10 9mm x 3 34 H 84 8mm x 1 03 D 26 2mm Weight camera head only
10. on the headlight with the camera 4 Connect the headlight cable to your Luxtec light source 5 Turn on the lightsource and the camera power The camera power switch is located on the front panel of the CCU 6 Look at the front of the monitor A picture should be visible on the monitor CAUTION The camera head MUST be connected to the CCU PRIOR to turning on the CCU Connecting the camera head to the CCU while the power is on will damage or destroy the video chip If you still do not have a picture make sure you have selected the same Line A or B that you have selected to in the rear of the monitor If you still do not have a picture turn OFF the camera power and check all of your connections on the camera recording device printer and monitor Turn the camera power back on If you still do not have a picture please contact your local distributor N White Balance White balance optimizes the color definition at different illumination levels White Balance before each procedure is strongly recommended 1 Fully open the iris of the headlight module 2 Point the camera and headlight at a white object Make sure the image fills the monitor entirely 3 Press the WB button on the front of the CCU and hold for 5 seconds The camera will white balance automatically N Troubleshooting Problem Cause Camera not turned on Camera head not connected to con CCU not plugged into AC outlet TP Monitor not tured on Mo
Download Pdf Manuals
Related Search
Related Contents
InnoPet IPS-075 User's Manual Health Navigation Toolkit - Iowa Primary Care Association Owner`s Manual Manual del Propietario Guide D`Utilisation Seminario sobre la gobernanza alternativa de las migraciones comprendere i messaggi delle nostre articolazioni control unit systems and parts ORANGE CLEANING POWER ® DIAMOND PROCESS Istruzioni d`uso Moisture Analyzer MJ33 Town & Country 2040 op complete.qxp Copyright © All rights reserved.