Home

Service Manual - Masterxoloda.ru

image

Contents

1. 4 Replace the defect compressor with a new one Re install the accessories wires amp screws in the opposite steps REPLACING THE OVERLOAD PROTECTOR 7 P2011 e OF THE COMPRESSOR Take off the accessories for the overload protector Take off the defect overload protector and replace it with a new one Re assemble the accessories for the overload protector in the opposite steps REPLACING THE COMPRESSOR CAPACITOR Take off the wires for the compressor capacitor Take off the defect compressor capacitor and replace it with a new one Re assemble in the opposite steps REPLACING THE DOWN MOTOR FOR CONDENSER Take off the front amp rear plates of the machine Unscrew the front amp rear fixers for the condenser Take off the rear fixer Take off the funnel of the condenser Take off the defect motor and replace it with a new one Re assemble the front amp rear plates and funnel in the opposite steps REPLACING THE DOWN MOTOR CAPACITOR FOR CONDENSOR Take off the rear plate of the machine Take off the wires for the capacitor then take off the capacitor Replace with a new one Re assemble in the opposite steps REPLACING THE UP MOTOR FOR EVAPORATOR Take off the front amp rear plate of the machine take off the up wind funnel for the evaporator and wires for the fan motor Unfasten the motor Take off the motor and replace with a new one Re assemble in the opposite steps REPLACING T
2. AY BALLU Service Manual AC N006R AC NO06RH AC T006R AC T006RH ROBLEM POSSIBLE CAUSE SOLUTION Water leakage Rubber plug at the rear plate of the machine Put back the rubber plug is out of place Water tube inside the machine is not in the Check and reinstall or replace the water place or broken tube inside the machine Water tube is of bad connection or broken Check or replace the water tube Weak cooling Dusty filter Clean the filter Dusty condenser Air vent is blocked The room temperature is too high Too many windows or doors are open Insufficient refrigerant or the refrigerant leaks out HEAT PUMP is broken Use a high pressure air spray to clean the dust Do not touch the condenser directly it is very hot now Remove the blockade It s out of the working range of the machine Close the windows doors Please check Is the current power consumption decreasing Is the suction pressure of the machine too low Is the temperature of the discharging tube too high Is the suction tube frozen in ambient temperature 7 Replace the heat pump Machine does not work at all Bad connection of the mains and plug P C Board fused P C Board or transformer breaks down Bad connection of the wires Re plug the power cord Check and replace Check and replace Check and replace Compressor doesn t work only the fan to circulate the air Voltage Frequency is too low Ov
3. HE UP MOTOR CAPACITOR FOR EVAPORATOR Take off the rear plate of the unit Unfasten the screws of the motor capacitor Take off the motor capacitor and replace 1t with a new one Re install in the opposite steps REPLACING THE FAN BLADE OF THE EVAPORATOR Take off the front amp rear plates Take off the up wind funnel of the evaporator Unfasten the motor and fan blade of the evaporator Replacing the defect fan blade Re install in the opposite steps REPLACING THE PUMP MOTOR Take off the front amp rear plates Unfasten the wires for the pump motor Take off the defect pump motor and replace it with a new one Re install in the opposite steps REPLACING THE HEAT PUMP 4 WAYS VALVE For AC N006RH AC T006RH only Take off the front amp rear plates Take off the evaporator wind funnel amp motor Unfasten the fixer for the middle spacer Take off the heat pump 4 ways valve Re assemble in the opposite steps REPLACING THE MICROSWITCH Take off the front and rear plates Take off the wires for the micro switch Take off the lever Take off the micro switch Replace the defect micro switch with a new one Re assemble in the opposite steps REPLACING THE CONTROL PANEL Take off the front amp rear plates Take off the control panel and its wires Replace with a new one Re install in the opposite steps After Check Please do the following checks after repair Make sure the working curre
4. ck and replace Bad installation of the water pump Re install Micro switch breaks down Check and replace Suction pressure is too Blocked capillary Replace the capillary low while the suction temperature is too high Blocked evaporator Blocked refrigerant filter Insufficient refrigerant or the refrigerant has been leaked Use high pressure N to clean the evaporator or replace it Replace the refrigerant filter Release the remained refrigerant vacuum the unit at least over 755mmHg Recharge the unit For correct refrigerant amount please refer to the rating label at the back of the unit The deviation should be within 3g PROBLEM POSSIBLE CAUSE SOLUTION Suction temperature amp suction pressure are too low Room temperature is too low Dusty Evaporator R P M of the fan motor is low Air return of the evaporator is blocked Air supply of the evaporator is blocked Increase the room temperature Clean the evaporator Increase the R P M of the motor Remove the blockade Remove the blockade Discharge pressure is too high Condenser is too dusty Air return of the condenser is blocked Exhaust tubes of the condenser is pressed or blocked R P M of the down motor too low Too much refrigerant Room temperature too high Clean the condenser Remove the blockade Check the exhaust tubes Increase the R P M Release all the refrigerant vacuum then rechar
5. erload protector of compressor breaks down Compressor capacitor breaks down Compressor breaks down P C board breaks down Room temperature is too low Check it by a voltmeter Check and replace Check and replace Check and replace Check and replace It is out of the working range of the machine PROBLEM POSSIBLE CAUSE SOLUTION Compressor works but Bad connection of the wires Check and reconnect or replace the fan doesn t Fan motor breaks down Check and replace Fan motor capacitor breaks down Check and replace P C board breaks down Check and replace Fan blade is stuck Fix it Big noise Screws nuts of the fan for evaporator Check and fasten condenser come loose Screws nuts of the compressor come loose Fan blade is blocked by something Check and fasten Remove the blockade Big vibration Screws nuts of the compressor come loose Fan of the evaporator or condenser does not fix well or is deformed The metal tubes inside the machine hit the other parts Check and fasten Check and replace Adjust the position of the tubes Motor doesn t work Wires problem Check and replace Loose terminal connection Check and fasten Motor breaks down Check and replace Motor capacitor breaks down Check and replace The fan blade is stuck Fix it Auto drainage system Wires problem Check and replace doesn t work Pump motor breaks down Che
6. ge For correct refrigerant amount please refer to the rating label at the back of the unit The deviation should be within 3g Re switch the unit after the temperature drops down Discharge temperature is too high Refrigerant is too less or has been leaked Condenser too dusty Air return of the condenser is blocked Air supply of the condenser is blocked R P M of down motor too low Release the remained refrigerant vacuum the unit at least over 755mmHg Recharge the unit For correct refrigerant amount please refer to the rating label at the back of the unit The deviation should be within 3g Clean the condenser Remove the blockade Remove the blockade Discharge pressure too low Room temperature too low Refrigerant is too less or has been leaked R P M of the down motor too high thus the air volume is too big This is normal situation please increase the room temperature Release the remained refrigerant vacuum the unit at least over 755mmHg Recharge the unit For correct refrigerant amount please refer to the rating label at the back of the unit The deviation should be within 3g Adjust the R P M of the down motor to the acceptable one How to REPLACING THE COMPRESSOR Take off the overload protector and wires of the compressor Take off the suction and discharging tubes Unfasten the screws on the compressor Take off the accessories for the compressor 40
7. nt is correct DEY Make sure the wire distribution is correct according to the supplied diagram Make sure the pipes tubes are in the right position do not hit with the other parts Make sure the insulation resistance between the plug and grounding is over 2MQ Make sure the whole cooling system is of no leakage Make sure the fan operates normally and does not hit the other parts Make sure the compressor can operate normally without abnormal noise Set the machine to max cooling and high ventilation after 30 minutes put your hand on the evaporator to check it is making the cooling or not Measure the temperature at the air inlet and outlet make sure the temperature difference is over 10 C Make sure the water tray water pipe inside the machine are of no leakage and well installed

Download Pdf Manuals

image

Related Search

Related Contents

Multiquip Saw TP24X User's Manual  1. About Lepide Active Directory Self Service  Reactive Power Controller Operating instructions  HM703U A      Disfrute de nuevo de aire puro en su coche gracias a Wynn`s  Samsung Monitor FHD touch da 24" S24C770T User Manual  バリオハーネス 取扱説明書 株式会社ロストアロー  SOUTH CAROLINA - Wando AFJROTC  