Home
        ArtAssist - deprimo.ie
         Contents
1.    Azizi  A A   Stevens  R J G   Wolfe  J H N  and Nicolaides  A N   Irvine Lab for Cardiovascular Investigation and Research Academic Vascular Surgery  Imperial  College School of Medicine  St Mary   s Hospital  London  U K  Eur J Vasc Endovasc Surg 19   261 269  2000      Enhancing Venous Outflow in the Lower Limb with Intermittent Pneumatic  Compression  A Comparative Haemodynamic Analysis on Effect of Foot vs  Calf vs  Foot  and Calf Compression  Delis  K T   Slimani  G   Hafez  H M  and Nicolaides  A N  Irvine  Lab for Cardiovascular Investigation and Research  Academic Vascular Unit  Imperial College  School of Medicine  St Mary   s Hospital  London UK  Eur J Vasc Endovasc Surg 19  250 260   2000      Effect of Posture on Popliteal Artery Hemodynamics  Delis  K T   Nicolaides  A N  and  Standsby  G  Irvine Lab for Cardiovascular and Investigation and Research  Academic  Vascular Surgery  Imperial College School of Medicine  St Mary   s Hospital  London UK  Arch  Surg  2000  135 265 269     Rapid Intermittent Compression Increases Skin Circulation in Chronically Ischemic Legs  with Infra popliteal Arterial Obstruction  Van Bemmelen  P S   Weiss Olmanni  J  and  Ricotta  J J  Div  of Vascular Surgery  State University of New York  Stony Brook  VASA  2000  29 47 52     Pneumatic Limb Compression  A Free Lunch  Porter  JM  Division of Vascular Surgery   Oregon Health Sciences University  J Vasc Surg 2000 31 821 2    Improving Walking Ability and Ankle Brachial Pressure Indi
2.    Mansour  Ashraf M   Borge  Marc  The Department of Surgery  Loyola University  Medical Center  Maywood Ill  Journal of Vascular Surgery  October 2005  Volume 42  Number  4  710 716     External Intermittent Compression Increases Collateral Artery Number and Size  Following Femoral Artery Occlusion  van Bemmelen  Paul S   Choudry  Rashad  Salvatore   Michael D   Goldenberg  Marat  Goldman  Bruce  Blebea  John  Temple University   Philadelphia  PA  VascularWeb  Provided by the Society for Vascular Surgery 2006     L 5 14 Rev  006  Effective Date  April 20  2007    19    44     45     46     A Randomized  Placebo Controlled Limb Salvage Trial Using the ArtAssist Pneumatic  Compression Device  George Louridas  MD  Univeristy of Manitoba  Winnipeg  Canada   2006     Non Operative Active Management of Critical Lower Limb Ischaemia  CLI   Initial  Experience Using a Sequential Compression Biomechanical Device  SCBD  for Acute  Limb Salvage in CLI  Esan  O   Mahendran  B   Fahy  A   Hynes  N   Twafink  S   Zalatel  E    and Sultan  S  Western Vascular Institute  University Hospital Galway  Ireland  Presented at  the European Society for Vascular Surgery  Sept  2006  Prague     Politeal Artery Volume Flow Measurement  A New and Reliable Predictor of Early  Patency After Infrainguinal Balloon Angioplasty and Subintimal Dissection  Ascher E    MD  Hingorani  A P   MD  and Marks  N A   MD  RVT  Maimonides Medical Center  Division  of Vascular Surgery  J of Vas Surg  Volume 45  Number 
3.   4    ArtASSISst    the Arterial Assist Device   Model AA 1000    Operations and Service Manual          1857 Diamond Street    San Marcos  California 92078   USA  Telephone   760  744 4400   Toll Free   888  4 LEG FLO  Fax   760  744 4401   E mail  info acimedical com    www artassist com    L 5 14 Rev  006  Effective Date  April 20  2007  AD2 00201 and above    TABLE OF CONTENTS    OPERATIONS MANUAL  TO 3  How Lo edad A A tds 4  Indications  Contraindications   uses Code di iio 5  Safety Considera OS   uo eroe re ver SS AI AR AA 6  MEAD RANCIO 7 8  Physical  IescripioD  a 9 10  Internal Pressure Adjustment  amp  Patient Compliance Assessment                    sssssss 11  E E                 12  Patient s Instructions For Use         0    ccc cece ccc cece eee eese 13 14  Packing INSU CONS  caes d A Ada as 15  RAICES ARO RRA a 16 20  European Authorized Representative       ooooocccocconconcconcnnccononncnnnonncnnconacnncanacos 21  SERVICE MANUAL   PAM de ed a ES 23  Pressure and Timing Prol ide 24  Pressure AUS aero rotando 25  Tank Flushing Instructions aso o ea or cer E RON OR Ib e Ree cU TP EE coniayeuudondet 26  Tro  bleshootine soscexums crean ee TAN uns O 27 29  APPENDIX   Electrical Schmid Appendix A    L 5 14 Rev  006  Effective Date  April 20  2007    OPERATIONS MANUAL    INTRODUCTION    When you finish reading this operations and service manual  you will become an  ArtAssist  Model AA 1000 expert  Well  maybe not an expert  but our hope at ACI  Medical  LLC  is 
4.   Exercise and Pneumatic Foot and Calf Compression  Preliminary Results at Six Weeks of  a Randomized Controlled Study  Kakkos  S   Geroulakos  G   Nicolaides  A N   Standfield   N  Vascular Unit  Ealing Hospital and Department of Vascular Surgery Hammersmith  Hospital  London  UK  Presented at the XI Congress of the Mediterranean League of  Angiology and Vascular Surgery  May 30 June 2  2001  Chios  Greece     Limb Salvage Using High Pressure Intermittent Compression Arterial Assist Device in  Cases Unsuitable for Surgical Revascularization  van Bemmelen  P   Gitlitz  D B   Faruqi   R M   Weiss Olmanni  J   Brunetti  V A   Giron  F   Ricotta  J J  Dept of Vascular Surgery and  Podiatry  VA Medical Center  Northport  NY  and the Division of Vascular Surgery  State  University of New York at Stony Brook  Arch Surg  2001  136 1280 1285     The ArtAssist   Device in chronic lower limb ischemia  A pilot study  Louridas  G   Saadi   R   Spelay  J   et al  Section of Vascular Surgery  the Department of Surgery and the  Department of Rehabilitation Medicine  University of Manitoba  St  Boniface Hospital and  Health Sciences Centre  Winnipeg  Manitoba  Canada  Int Angiol 2002  21 28 35     Intermittent Pneumatic Compression for the Treatment of Lower Extremity Arterial  Disease  A Systematic Review  Labropoulos  Nicos  Wierks  Carls  and Suffoletto  Brian   Department of Surgery  Loyola University Medical Center  Maywood  IL USA  Vascular  Medicine 2002  7 141 148     Critical Limb I
5.  Controlled Trial with 1 Year Follow up  Delis  K T   Nicolaides  A N     Cheshire  N J W   and Wolfe  J H N  Academic Vascular Surgery  St  Mary s Hospital   London  UK  The Vascular Surgical Society of Great Britain  amp  Ireland  Nov  2000  London  Arena     L 5 14 Rev  006  Effective Date  April 20  2007    17    22     23     24     25     26     27     28     29     30     31     32     Effects of Intermittent Pneumatic Compression of the Calf and Thigh on Arterial Calf  Inflow  A Study of Normals  Claudicants  and Grafted Arteriopaths  Delis  K T     Husmann  J W    Cheshire  N J    and Nicolaides  A N  Imperial College School of Medicine   St  Mary   s Hospital  London  UK  Surgery  2000  vol  129  no  2  p  188 195     The ArtAssist   Device in Chronic Lower Limb Ischemia  A Pilot Study  Louridas  G    Saadia  R   Spelay  J   Abdoh  A   et  al  Sect  of Vas  Surg   Dept  of Surg  and Dept  Of Rehab  Medicine  Univ  of Manitoba  St  Boniface Hospital and Health Sciences Centre  Winnipeg   Manitoba  Canada  Presented at the Canadian Vascular Society meeting  Banff  Alberta  Sept   2000     Intermittent Pneumatic Foot  amp  Calf Compression in Vascular Claudication  A  Randomized Trial  Delis  K T   Nicolaides  A N   Cheshire  N J   and Wolfe  J H  St  Mary   s  Hospital Imperial College  London  UK  Presented at the 29th Annual Symposium on Vascular  Surgery  Boca Raton  FL  April 2001     Improvements of the Walking Ability in Intermittent Claudication with Supervised
6.  Hospital Use  1  Clean the device between different patient   s use or after 1 month by the same patient     2  Wipe all areas of the device using a cloth and an EPA registered hospital grade  disinfectant following the manufacturer   s Material Safety Data Sheet  It is  recommended that hospital gloves be used to prevent the possible spread of  infections     Clean all visible soiling     4  If blood or body fluids are present on the device  follow the 2 step cleaning process  recommended by OSHA     a  Apply an EPA registered tuberculocidal disinfectant  Remove and clean all  visible soil     b  Wipe down with 1 100 sodium hypochlorite solution   5  Remove gloves and wash hands thoroughly     6  Allow the device to dry before reusing     The pressure delivered to the cuffs should be checked at least annually by connecting a  calibrated pressure gauge  available from ACI  to any one of the controller   s pneumatic  outlet connectors  Pressure accuracy of   10mmHg is adequate according to the most  recent clinical studies  which are available from ACI upon request at no charge     Check for overpressure alarm operation by increasing the regulator   s output to 170mmHg    10mmHg with the pressure gauge attached  Alarm should activate after one second   Check for improper deflation alarm operation by temporarily plugging the outlets of the  6mmHg relief valves  Alarm should activate after 10 seconds     Check the connectors and tubing sets at least annually for integrity and p
7.  Observe labels for    foot    and    calf    for  proper attachments   Sit in a comfortable chair with legs resting in a downward position or on the floor   Apply power with the POWER switch located on the front panel  The switch will illuminate to show the device is on   The controller will turn off automatically after one hour   Check for skin condition changes after each use and notify physician of any worsening   Clean this control unit with a damp cloth containing mild disinfectant solutions or detergents and water   Use this device only as prescribed by your doctor  Do not use for any other purpose or on other individuals     Front Panel Lights  TIMED OUT will light after the controller has operated for one hour  Turn the power switch to OFF and then back to ON  when compression therapy is to resume   REPAIR LEAK will light when the controller cannot operate at the proper pressure  Check the cuffs  tubing and  connectors for possible leaks   REPAIR will light when there is something wrong with the controller that can only be repaired by qualified service  personnel  Call for service     CAUTIONS    Use under medical supervision    Federal law restricts this device to sale by or on the order of a physician    While using oxygen  position this device only at the foot of the bed or as far as possible from equipment  administering oxygen     CONTRAINDICATIONS Do not prescribe or use this device   During episodes of inflammatory phlebitis or pulmonary embolism   When deep v
8.  curved part of the  front panel to the packing foam     2  Put the tubing  power cord and videotape into the white accessory box and slide it  down into the slots in front of the controller   s front panel  Figure 9      3  Use the tape enclosed to seal the box  as shown in Figure 10     4  Place the Federal Express Airbill that was sent with the ArtAssist   device on the top  of the box  as shown below     5  Telephone Federal Express at 1 800 GO FEDEX  1 800 463 3339   then press the    key when connected     TOP VIEW LOOKING DOWN TAPE    ARTASSIST   CONTROLLER   gt  f ev iy  AIRBILL U 77         FOAM  PACKING    ACCESSORY      F    BOX    Figure 9 Figure 10    IMPORTANT  Keep all packing materials and use it to the device  power cord   VHS DVD  and tubing to ACI     L 5 14 Rev  006  Effective Date  April 20  2007 15    10     11     REFERENCES    Augmentation of Blood Flow in Limbs with Occlusive Arterial Disease by Intermittent  Calf Compression  van Bemmelen  P S   Mattos  M A   Faught  W E   Mansour  M A    Barkmeier  L D   Hodgson  K J   Ramsey  D E   and Sumner  D S  Springfield  IL  J of Vas  Surg 1994  19 1052 8     Intermittent Pneumatic Compression Therapy in Patients with Leg Ischemia  Banga  J D    Idzerda  H H D   Schuurman  J G   and Eikelboom  B C  Vascular Center  Academic Hospital   Utrecht  the Netherlands  17    World Congress International Union of Angiology  London   April 1995     Intermittent Calf and Foot Compression Increases Lower Extremity Blood 
9.  doctor and follow the prescribed  schedule     IMPORTANT     Y Y  eo eo    Y  eo    Y    Y    Y  eo    Y  eo    Call ACI with any questions before use at  888  4 LEG FLO   Remove cuffs before walking or YOU MAY SLIP AND FALL     Report any adverse skin changes  pain  infection  or other medical issues to your  doctor     This device is for use only on the prescribed patient  It is not to be used on others   ELECTRICAL HAZARD  Do not operate in wet areas or with wet hands  feet  etc     If you experience any problems with ArtAssist    controller  tubing  cuffs  or the  electrical cord  please contact your local representative or ACI at  888  4 LEG FLO     Please refer to the    Rental Agreement And Doctor   s Prescription    that you and your  physician signed for additional information     DO NOT MACHINE WASH THE CUFFS  WIPE WITH A MOIST CLOTH  ONLY     Velcro   is a registered trademark of Velcro Corp     L 5 14 Rev  006  Effective Date  April 20  2007    14    PACKING INSTRUCTIONS    Upon termination of your prescription by your doctor  return the device  the power cord   tubing  and the instructional videotape to ACI by using the Federal Express Airbill that  was sent with the device  Do not send back the cuffs  they are yours to keep     1  Carefully pack the controller with its top handle facing up and curved front panel  matching the curved part of the front panel to the bottom packing foam  Put the top  packaging foam over the top of the controller again  matching the
10.  three basic components  an electrically operated controller   tubing sets that conduct the air pulses from the controller to the cuffs and single patient  use limb cuffs  The controller is connected to a wall outlet for power using the included  power cord  Either one or two pneumatic limb cuffs can be attached to the controller via  pneumatic fittings  The cuffs are for use on either left or right limbs and are    one size fits  all     The only control available to the user of the controller is an ON OFF power switch  that illuminates when power is applied  Pressure and time parameters have been  optimized for the population of ischemic patients  but in rare cases  the applied pressure  may be altered by opening the front panel     In three separate studies  this device was shown to significantly improve pain free    walking distance in patients with intermittent claudication and that those improvements  were long lasting after therapy was discontinued     L 5 14 Rev  006  Effective Date  April 20  2007    10     HOW TO GET STARTED    Unpack items and SAVE ALL PACKING MATERIALS AND PAPERWORK   You will need this to return the device to ACI     Place controller by a chair for use in therapy     Plug power cord into a wall outlet and the opposite end into controller  located on  the lower side     Plug the tubing set with the black plastic connector at the end into the upper side of  the controller  Plug all the way in     Connect the other end of the tubing set into the com
11. 1 17 24  January 2007     L 5 14 Rev  006  Effective Date  April 20  2007    20    TROUBLESHOOTING    PATIENT    If the device is not operating        1  Check if the power cord is plugged into both controller and wall outlet     2  Is the power switch turned on and is the power switch illuminated     If alarm indicators appear  to the right of the power switch         1  Immediately stop use   2  The audio alarm will sound with any visual indicator appearing      gt  TIMED OUT indicates the device has been continuously in use for about one  hour  Cycle controller power to reset the one hour timer and to continue use of  the device  as prescribed      gt  REPAIR LEAK indicates an under pressure condition  most likely due to an air  leak somewhere in the system  Check for leaks in the cuffs  tubing  and  connectors  The pump may be malfunctioning or there may be a leak elsewhere in  the system  It takes between 170 and 290 seconds of a leak condition to activate  the alarm  A leak is considered significant if pressure is not able to exceed 60  mmHg      gt  REPAIR indicates that there is a problem in the system that is not leak related   3  Next call ACI at 888 4 LEG FLO  888 453 4356      If the cuff pressure feels weak   1  Listen for air leaks in the cuffs     2  Lasten for air leaks in the tubes     3  For rental customers  if there is a leak in the cuffs or the tubes  notify ACI Medical  immediately  Cuffs and tubes will be replaced for normal wear and tear damage at  no 
12. Flow  Eze   A R   Comerota  A J   Cisek  P L   Holland  B S   Kerr  R P   Veeramasuneni  R   and  Comerota  A J  Jr  Temple University School of Medicine  Philadelphia  PA USA  24  Annual  meeting of the Society for Clinical Vascular Surgery  March 1996  Am J Surg 1996  172 130   135     Acute Effects of Intermittent Pneumatic Foot and Calf Compression on Lower Limb  Venous Hemodynamics  Labropoulos  N   Buckman  J   Size  G   and Wightman  R  Vascular  Diagnostics  Ltd   Parkridge  IL  Division of Surgery  Loyola Medical Center  Maywood  IL   Society of Vascular Technology 20  Annual Conference  San Francisco  CA  July 1997     Intermittent Foot and Calf Compression  Effects on Arterial Blood Flow and Value in  Treatment of Intermittent Claudication  Nicolaides  A N  and Delis K  24  Annual  Symposium on Current Critical Problems  New Horizons and Techniques in Vascular and  Endovascular Surgery  November 1997     Intermittent Pneumatic Foot and Calf Compression  Determining Its Optimal Effect on  Venous Haemodynamics Using Direct Pressure Monitoring  Delis  K   Zainal  A A    Stevens  R J G   Otah  K E   Ibegbuna  V   and Nicolaides  A N  Imperial School of Medicine   St Mary s Hospital  London UK  The American Venous Forum 10  Annual Meeting  Feb 1998     Improving Popliteal Artery Flow with Intermittent Pneumatic Foot and Calf  Compression  Delis  K   Labropoulos  N   Nicolaides  A N   Stansby  G   and Lumley  J   Irvine Laboratory for Cardiovascular Investigation and Res
13. ces in Symptomatic  Peripheral Vascular Disease with Intermittent Pneumatic Foot Compression  A  Prospective Controlled Study with One year Follow up  Delis  K   Nicolaides  AN  Wolfe   JHN  and Stansby  G  Imperial College School of Medicine  St  Mary   s Hospital  London  UK   J Vasc Surg 2000  31 650 61     The Acute Effects of Intermittent Pneumatic Foot versus Calf versus Simultaneous Foot  and Calf Compression on Popliteal Artery Hemodynamics  A Comparative Study  Delis   K T   Nicolaides  A N   Labropoulos  N   and Stansby  G  Imperial College School of  Medicine  St  Mary   s Hospital  London  UK  J Vasc Surg 2000  32 284 92     Enhancing Foot Skin Blood Flow in Patients with Infrainguinal Arterial Bypass Grafting  Using Intermittent Pneumatic Compression  Husmann  M J W  Delis  K T   Lennox  A F    Nicolaides  A N   Standsby  G  Irvine Laboratory for Cardiovascular Research  St  Mary   s  Hospital  London  UK  21    Conference on Microcirculation  June 2000     Effect of Intermittent Pneumatic Foot Compression on Popliteal Artery Haemodynamics   Delis  K T   Labropoulos  N   Nicolaides  A N   Glenville  B   and Stansby  G  Imperial  College School of Medicine  Academic Vascular Surgery  St  Mary   s Hospital  London  UK   Eur J Vasc Endovasc Surg  p 270 277  vol 19  no  3  March 2000     Improvement in Walking Ability  Ankle Pressure Indices and Quality of Life in Vascular  Claudication Using Intermittent Pneumatic Foot and Calf Compression  A Prospective  Randomized
14. dle adds 1  4    in height   Weight     23 pounds  controller only    Indicators     Located in  black out  on the front panel s black bezel just to the right of  the power switch     TIMED OUT indicates the device has been continuously in use for about one  hour     L 5 14 Rev  006  Effective Date  April 20  2007    REPAIR LEAK indicates an under pressure condition  most likely due to an air  leak somewhere in the system  Check for leaks in the cuffs  tubing and  connectors  The pump may be malfunctioning or there may be a leak elsewhere  in the system  It takes between 170 and 290 seconds of a leak condition to  activate the alarm     REPAIR indicates that there is a problem in the system that is not leak related   Refer to the Trouble Shooting section     Generally  cycling the controller   s power by turning it off then back on will reset  the indicators     2  Tubing sets     Two included in bilateral system  Six feet long   ID  2   OD vinyl   dual lumen with keyed  proprietary connector for attaching to the controller and barb  fittings to attach to the cuffs     3  Compressions cuffs   FOR SINGLE PATIENT USE ONLY  Two tubing sets and  compression cuffs are included in a bilateral system           2     Outside surface     Heavy duty nylon tricot of hook compatible loop with polymer  lamination for air bladder integrity  There are two internal bladders  one for the  foot and ankle regions  another for the calf region     Inside surface     Napp nylon tricot cloth with p
15. earch  Academic Surgical Unit   Imperial College school of Medicine  St Mary   s Hospital  London UK     The Contributions of Arterial and Venous Volumes to Increased Cutaneous Blood Flow  during Leg Compression  Eze  A R   Cisek  P L   Holland  B S   Comerota  AJ  Jr    Veeramasuneni  R   and Comerota A J  Philadelphia  Pennsylvania  Charlotte and Gastonia   North Carolina  Annals of Vascular Surgery  1998  12 182 186     Acute Effects of Intermittent Pneumatic Compression on Popliteal Artery Blood Flow   Labropoulos  N   Watson  W C   Ashraf Mansour  M   Kang  S S   Littooy  F N   Baker  W H   The Department of Surgery  Loyola University Medical Center  Maywood  IL  Arch Surg   1998  133 1072 1075     Intermittent Foot and Calf Compression  A Novel Way to Treat Intermittent  Claudication  Nicolaides  A N  Imperial College School of Medicine  St Mary s Hospital   London UK  4   Annual Congress of the International College of Angiology  Sapporo  Japan   July 1999     Case Study and Literature Review  Treatment of Non healing Lower Extremity  Ulceration with a New Form of Progressive  Rapid  Pneumatic Compression  Shebel     L 5 14 Rev  006  Effective Date  April 20  2007    16    12     13     14     15     16     17     18     19     20     21     N D   Amundsen D   and Arkans E  General Surgery Section of Vascular Surgery  Kaiser  Permanente Medical Center  Panorama City  CA      Optimum Intermittent Pneumatic Compression Stimulus for Lower limb Venous  Emptying  Delis  K T
16. ein thrombosis is diagnosed or suspected   When increased venous or lymphatic return is undesirable including presumptive evidence of congestive heart  failure   On limbs with uncontrolled infection   When pain increases significantly or with worsening skin tissue condition     PRECAUTIONS    1  The doctor is advised to make frequent observations of treated limbs for skin lesions and signs of infection   2  Use of ArtAssist   with acute arterial thrombi may cause distal embolization     DANGER Risk of explosion  Do not use this device in the presence of flammable anesthetics or other    flammable gases     DANGER For grounding reliability  plug only into a three pronged grounded outlet  When used in a health care  facility  use only with an outlet labeled    Hospital Grade        US pat  no  5 218 954  Israel pat  no  106 258  RSA pat  No  93 4841  Other US and foreign pat   s  pending        90 2493 01 ACI Medical  LLC   San Marcos  CA  USA Tel  888 4 LEG FLO 115V  60Hz  0 4A    L 5 14 Rev  006  Effective Date  April 20  2007    PHYSICAL DESCRIPTION    ArtAssist   Model AA 1000       Figure 1    1  Controller  Specifications  Unilateral or Bilateral  System     Operating Voltage Model Number Max  Current  115 V  60 Hz AA 1000 0 4 Amps  220 V  50 Hz AA 1000e 0 2 Amps  100 V  60 Hz AA 1000n 0 5 Amps    Maximum Operating Temperature  85   F degrees   Power cord     at least 6 feet long  hospital grade plug  universal female  Size     10    wide  12  high  7  4 deep  The top han
17. etherlands     Intermittent Pneumatic Calf and Foot Compression Improves Walking Distance in  Patients with Claudication  Results of a Randomized Study  Ramaswami  G   D    Ayala  M    Hollier  L H   Brem  H   McElhinney  A J   Baylor College of Medicine  Houston  TX  New  York Methodist Hospital  Brooklyn  NY  Mount Sinai Medical Center  New York  NY   Veterans Administration Hospital  Bronx  NY  Presented at the 32nd Annual Symposium on  Vascular Surgery  Rancho Mirage  CA  March 2004     Haemodynamic Effect of Intermittent Pneumatic Compression of the Leg After  Infainguinal Arterial Bypass Grafting  Delis  K   Husmann  M   Szendro  G   Peter  N    Wolfe  J H   Mansfield  A O  Regional Vascular Center  Surgery and Department of Academic  Cardiology  St  Mary   s Hospital  Imperial College School of Medicine  London  UK     Improvement in Walking Ability  Ankle Pressure Indices and Quality of Life in Vascular  Claudication Using Intermittent Pneumatic Foot and Calf Compression  A Randomized  Controlled Trial  Delis  K T   Nicolaides  A N   Cheshire  N J W  Wolfe  J H N  St  Mary   s  Hospital  London  UK  British Journal of Surgery December 2002  Volume 88  Issue 4 605   606     Intermittent Pneumatic Compression Therapy for Peripheral Arterial Occlusive Disease   Strejcek  J   Arkans  E  Phlebology Digest 2004  Volume 17  Issue 1 5 8     Improvement of the Walking Ability in Intermittent Claudification with Supervised  Exercise and Pneumatic Foot and Calf Compression  Resu
18. extra charge for customers renting the ArtAssist  device     4  Check for kinked hose that prevents airflow to the cuff s      L 5 14 Rev  006  Effective Date  April 20  2007 27    TRAINED SERVICE PERSONEL USE ONLY    If the device is not operating     l   2     Check if the power cord is plugged into both controller and wall outlet     Is the power switch turned on and is the power switch illuminated     3  Disconnect power cord from controller and wall outlet  Open the front panel by  removing the two screws on the bottom of the controller and lift up  First check if  both 1A fuses  F1  F2  are intact and then check if the 5 Amp pump fuse  F3  is  intact  If both are intact  then the next step is to call our service department at 888 4  LEG FLO     If alarm indicators appear  to the right of the power switch         L   2     Immediately stop use     The audio alarm will sound with any visual indicator appearing                 TIMED OUT indicates the device has been continuously in use for about one  hour  Cycle controller power to reset the one hour timer and to continue use of  the device  as prescribed     REPAIR LEAK indicates an under pressure condition  most likely due to an air  leak somewhere in the system  Check for leaks in the cuffs  tubing  and  connectors  The pump may be malfunctioning or there may be a leak elsewhere in  the system  It takes between 170 and 290 seconds of a leak condition to activate  the alarm  A leak is considered significant if pressure i
19. iquids onto the control units  This can cause possible damage to  the unit     After therapy  be sure to put it in a safe place and out of reach of children     If rented  return the device and accessories to ACI promptly after Physician orders  discontinuation of its use     Stop use if alarm sounds and refer to Trouble Shooting section     There is no known potential electromagnetic or other inference between the  ArtAssist  device and other devices     L 5 14 Rev  006  Effective Date  April 20  2007    LABELS    On Top Of Controller         ArtAssist     the Arterial Assist Device       Produced under license by Dr  Paul S  van Bemmelen     ACI Medical  LLC     On Bottom Of Controller    DANGER Risk of electric shock  Disconnect power cord before opening or servicing  this device     WARNINGS  1     Only qualified service personnel should repair this device  Improper repair may result  in serious injury  death  equipment damage or malfunction    2  For continued protection against fire and shock hazards  replace internal fuses only  with same type and rating  GMA 1 0 Amp   90 2491 01       L 5 14 Rev  006  Effective Date  April 20  2007    On Side Of Controller    Abbreviated Instructions Refer to the instruction manual for further details    1  Apply compression cuff to affected limb over all bandages and clean socks  Do not allow compression cuff to  contact broken  irritated or ulcerated skin   Attach the cuff s hoses to appropriate connectors and into the control unit 
20. lts at Six Months of a  Randomized Controlled Trial  S Kakkos  G Geroulakos  A Nicolaides  Vascular Unit  Ealing  Hospital and Department of Vascular Surgery Imperial College  London  UK  Presented at the  2004 European Society for Vascular Surgery Annual Meeting     Effect of Intermittent Pneumatic Compression of Foot and Calf on Walking Distance   Hemodynamics  and Quality of Life in Patients with Arterial Claudication  A Prospective  Randomized Controlled Study with 1 Year Follow up  Konstantinos Delis and Andrew N   Nicolaides  Annals of Surgery March 2005  Volume 241  Number 3 431 41    Rapid Food and Calf Compression Increases Walking Distance in Patients with  Intermittent Claudication  Results of Randomized Study  Ramaswami  G   D   Alaya  M    Hollier  L   Deutsch  R   McElhinney  A J  Houston  Tex  Brooklyn and Bronx  NY  New  Orleans  LA  and San Diego  CA  J  Vasc Surg  May 2005  Volume 41  Number 5 794 801    Improvement of the Walking Ability in Intermittent Claudication due to Superficial  Femoral Artery Occlusion with Supervised Exercise and Pneumatic Foot and Calf  Compression  A Randomised Controlled Trial  Kakkos  S K   Geroulakos  G   Nicolaides   A N  Imperial College of Science  Technology and Medicine  London U K  Eur J Vasc  Endovasc Surg  August 2005  Volume 30  164 175     Hemodynamic Effects of Intermittent Pneumatic Compression in Patients with Critical  Limb Ischemia  Labropoulos  Nicos  Leon  Luis R  Bhatti  Ahmad  Melton  Steven  Kang   Steven S
21. ng down  Figure 2   Center your foot over the cuff  Figure  3   Bring the side straps over the top of the foot and attach them snugly with the  Velcro  like hook tape  Figure 4   Bring the back heel strap around the ankle and  attach it  Figure 5      CALF  Center the remaining cuff behind your calf  Attach the upper and lower  straps snugly around the front of the leg with Velcro  like hook tape  Figure 6    Plug the barbed hose connector labeled    TO FOOT    into the lower cuffs hose  fitting on the side of the ankle  Figure 7   Plug the barbed hose connector labeled     TO CALF    into the upper cuff s hose fitting behind the calf or use integral dual  connectors   Figure 8         Figure 2 Figure 3 Figure 4 Figure 5    L 5 14 Rev  006  Effective Date  April 20  2007       13       Figure 6 Figure 7 Figure 8    STEP 3    Sit with feet on the floor and then turn on the power switch on the controller to begin  therapy  Turn off the switch to end therapy or wait for the 1 hour    timed out     indicator depending on your prescription  Turn off power to stop the audible and  visual indicators     It is recommended to use this device at least 3 4 hours a day  for 1 hour intervals or as  instructed by your doctor   Ideally  60 minutes in the morning  60 minutes in the  afternoon  60 minutes in the evening and 60 minutes before bedtime  For those who  work or unable to work around the ideal schedule  1 2 hours in the morning and 1 2  hours at night may be adequate   Consult your
22. olymer lamination     4  Instructions     An instructional video  DVD   pictorial instruction  sheet and  operations and service manual are supplied with all units     Note  Instruction manuals are not included with rental units because the VHS DVD and  pictorial instruction sheet are sufficient for proper operation  Most physicians wish the  patient to be unaware of the internal clock that monitors patient compliance     L 5 14 Rev  006  Effective Date  April 20  2007    10    INTERNAL PRESSURE ADJUSTMENT AND  PATIENT COMPLIANCE ASSESSMENT    Pressure Adjustment   The ArtAssist  device has undergone clinical testing  to determine the optimal timing  and pressure settings for maximizing the increase of arterial inflow  The timing  parameters are therefore not adjustable  However  patients with ischemic rest pain or  other conditions may experience discomfort from the factory pre set pressure of 120  mmHg  When that is the case  the pressure may be reduced by the clinician only  by  turning the pressure regulator knob counter clockwise  Compression with a lower  pressure may reduce the patient s pain and allow for gradual increase of pressure back to  120 mmHg as the patient is able  Make pressure changes by only using a pressure gauge   provided through ACI  Call 8884 LEG FLO to borrow a pressure gauge at no charge   The front panel is opened by removing the two screws located on the bottom of the  controller toward the front  Be sure to disconnect the power cord from the con
23. pression cuff  Plug barb fittings  labeled    To Foot Cuff    into the foot cuff and    To Calf Cuff    into the calf cuff     Keep any wound healing bandages in place and apply a white athletic sock on the  feet to be treated     Wrap compression cuffs around foot  ankle  and calf as shown on pictorial  instruction card or on the Instructional VHS DVD     Sit with feet on the floor and then turn on power switch on the controller to begin  therapy     After 1 hour therapy  the controller will stop compressing and    TIMED OUT    will  appear on the controller near the power switch  Removed cuff s  and store until the    next therapy session     Typically therapy consists of 1 hour compression  3 times a day  morning   afternoon and evening   Your doctor may prescribe a different usage for you     L 5 14 Rev  006  Effective Date  April 20  2007    INDICATIONS    This device is adjunct therapy for patients with ischemic disease of the lower limbs     It is indicated for patients with poor circulation including       REST PAIN  NIGHT PAIN   ULCERS     INTERMITTENT CLAUDICATION   ISCHEMIA     SMALL VESSEL DISEASE   GRAFT FAILURE     ARTERIOPATHIC WOUNDS   ANGIOPLASTY STENT FAILURE      MINOR AMPUTATIONS    CONTRAINDICATIONS    Infected limbs  Limbs with suspected deep vein thrombosis or arterial clots    During episodes of inflammatory phlebitis or pulmonary embolism    Ee be    When increased venous and lymphatic return is undesirable  such as congestive  heart failure     Preca
24. roper sealing and  for possible kinking of the hoses  Also  inspect the power cord for damage and replace as    necessary     Clean the fan filter annually or every 8000 hours  whichever is sooner     L 5 14 Rev  006  Effective Date  April 20  2007    12    PATIENT   S INSTRUCTIONS FOR USE    Review the VHS DVD and pictorial instructions that came with the device   If unavailable  follow the steps below     STEP 1    Set the controller by a chair for use in therapy  Plug the electrical cord into the  controller and the wall outlet  with power switch in the off position  Be careful not to  obstruct the air inlet  which is located on the side of the controller near the power  cord inlet  Plug the other end of the power cord into a properly grounded AC wall  outlet  Do not use an extension cord or a    cheater    adapter that eliminates the effect  of the ground pin on the outlet plug  In health care facilities  used only AC outlets  labeled    Hospital Grade        Plug the tubing set   s dual connector into the controller   s pneumatic outlet  Attach the  tubing   s barb connectors to the two elbow fittings on the cuffs by observing the  FOOT and CALF labels     STEP 2       Note how the cuff is assembled when it arrives  The foot area is folded to create a  sandal  Apply the cuff over a clean white sock with bandages left in place as des   cribed and pictured below     FOOT  Place the cuff open on the floor with the Velcro  like hook tape facing up  and the hose fittings faci
25. s not able to exceed 60  mmHg     REPAIR indicates that there is a problem in the system that is not leak related     The REPAIR alarm indicates one of the following possible problems     1     2     Overpressure     e When pressure applied to the cuff is greater than 170mmHg for more than 1  second  Check the regulator setting using a calibrated pressure gauge   provided by ACI     e When compression cuffs do not deflate and remain at  gt  30 mmHg   10mmHg  for 10 seconds  Check for proper operation of solenoid valves and 6mmHg  pressure relief valves     Pump temperature  If the pump motor temperature exceeds 58  C   2  C which  may be caused by a pump failure or cooling fan failure     The 12 volt solenoid value supply  If it fails completely  it is unable to power the  solenoid valves properly  Check power supply components  transformer  bridge  rectifier  BR2 or filter capacitor C23      L 5 14 Rev  006  Effective Date  April 20  2007    28    
26. schemia Successfully Treated by Intermittent Pneumatic Compression   Yoram Moses  MD and Boris Yoffe  MD  FACS  Department of General and Vascular Surgery   Marailai Medical Center  Ashkelon  Isreal  IMAJ  Vol 4  Issue 9  September 2002     Enhancing Foot Skin Blood Flux in Peripheral Vascular Disease Using Intermittent  Pneumatic Compression  Controlled Study on Claudicants and Grafted Arteriopaths   Delis  K T   Husmann  M J W   Nicolaides  A N   Wolfe  J H   and Cheshire  N J  World  Journal Surgery  Imperial College School of Medicine  St  Mary   s Hospital  London  UK     Intermittent Compression Pump for Nonhealing Wounds in Patients with Limb Ischemia   The Mayo Clinic Experience  1998 2000   Montori  V M   Kavros S J   Walsh E E   and  Rooke T W  Mayo Clinic  Rochester  MN  USA  Int Angiol 2002 21 360 6     Angiographic Improvement After Rapid Intermittent Compression Treatment   ArtAssist    for Small Vessel Obstruction  van Bemmelen  P   Char  D   Giron F   and  Ricotta J J  Dept  of Surgery  Div  of Vascular Surgery  State University of New York at Stony  Brook  NY  Ann Vasc Surg 2003  17 224 228     L 5 14 Rev  006  Effective Date  April 20  2007    18    33     34     35     36     37     38     39     40     41     42     43     Acute Effect of Intermittent Foot calf Compression on Skin Microcirculation in Patients  with Severe Leg Ischemia  Ubbink  D Th   van Iterson  V   Lagarnate  D A  Department of  Vascular Surgery  Academic Medical Center  Amsterdam  The N
27. to provide you with an informative manual to answer any questions you  might have regarding this device  This manual is filled with important information   useful tips and enlightening pictures to help you     GENERAL DESCRIPTION    The ArtAssist   device is the only external pneumatic compression device developed with  vascular surgeons for the sole purpose of increasing blood circulation and specifically   arterial blood flow  It applies impulse pressure to the foot  ankle  and calf  Single   patient use cuffs are made of soft durable material designed to last for months of therapy   Therapy takes place with the patient in a comfortable sitting position  The patient only  needs to turn the device on since all pressure and timing controls are pre set and hidden  from the patient  It is portable and suitable for home  clinic or hospital use     This device significantly increases patients    blood flow in the popliteal artery and at the  tissue level    9   Improvements were observed in calf blood flow using duplex ultra   sonic imaging and APG   Air Plethysmography     Further  it has been shown that calf and  foot region compression increases volumetric blood flow by better than three times that  of foot only compression as measured by duplex ultrasonography     Venous return flows  are increased over 5 times in muscular  superficial and deep veins    ArtAssist   has saved  limbs in severe cases where amputations below the knee were expected       ArtAssist   is composed of
28. troller  before opening the front panel     For instructions to adjust pressure  refer to page 25 in this manual     Timing Settings   All timing parameters have been established based upon clinical studies and are preset at  the factory  They are changeable only at the factory    Compression Time  3 seconds      0 5 seconds    Non Compression Time  17 seconds      3 seconds    DELAY between foot ankle and calf bladders  1 second      0 5 seconds    Pressure Rise and Fall Times  approximately 300 msec      100 msec     Patient Compliance Assessment   The Run time hour meter is located under the front panel toward the left side  It reads out  total time the controller is operated and cannot be reset  This is a tamper proof feature   Patient compliance can be easily assessed by subtracting successive meter readings  ACI  records the meter reading before the device is shipped  This reading is available to  clinicians by calling ACI  Please provide the serial number  patient name or prescribing  doctor s name     Close the panel using the screws to prevent further access     L 5 14 Rev  006  Effective Date  April 20  2007    11    MAINTENANCE    The device requires little maintenance  but it is recommended that hospitals maintain the  unit as required by hospital safety regulations  For home use  ACI recommends the  cleaning of the exterior case and tubing with a damped cloth of mild soap and water or  alcohol between different patient   s use     Suggested Cleaning Procedure for
29. ution  For use only under medical supervision  This device is restricted to sale by  or on the order of a physician     L 5 14 Rev  006  Effective Date  April 20  2007    SAFETY CONSIDERATIONS    SAFETY FEATURES     The device is safety fused for   1  Excessive current consumption by the controller  2  Excessive current consumption by only the internal pump    Alarms will sound if there are any problems concerned with overpressure  under  pressure  air leaks  power supplies  and pump temperature     A cooling fan is installed for temperature stability     In an alarm condition  power is removed from the pump and solenoid valves  which  exhausts pressure from all cuffs  The cooling fan remains on     If the unit loses power  all cuffs exhaust     SAFETY WARNINGS     Compression cuffs must be removed before walking or the patient MAY SLIP AND  FALL     Apply the cuffs over bandages and clean white cotton socks     ArtAssist   is to be used by the patient only  It is not to be used for any other person   nor for any other purpose than as prescribed by the Physician     The patient should contact their Physician if they notice a change of skin condition at  or near the sites of the cuff  such as any rash  redness  blister  etc  The patient should  examine the site before and after use     Proper use of the device is to be monitored by the patient and Physician  and not by  ACI     ELECTRICAL HAZARD  Do not operate in wet areas or with wet hands  feet  etc     Avoid spilling any l
    
Download Pdf Manuals
 
 
    
Related Search
    
Related Contents
  Manual de Purificador de aire por ionización Con control remoto  Manual de instalação de sensores de regulação de fluxo  User Manual - Axis Communications  Sanyo SC-505T User's Manual    Conceptronic IN-EAR HEADPHONE  Philips Soft-shell case DLN1757  USER MANUAL Made in the USA!      Copyright © All rights reserved. 