1.                                                                                      Service work should be performed only by qualified service technicians who are thoroughly familiar with all safety checks and the  servicing guidelines which follow     CAUTION   FOR CONTINUED PROTECTION AGAINST A  RISK OF FIRE REPLACE ONLY WITH SAME  TYPE FUSE   F7001  F7002  3 15A 250V     DVM    AC SCALE    1 5k ohm    10W    TO EXPOSED  METAL PARTS    CONNECT TO  KNOWN EARTH  GROUND    0 15   F    TEST PROBE    LC 32DH57E GY RU GY S GY    ii    Precautions for using lead free solder    Employing lead free solder            PWBs    of this model employs lead free solder  The LF symbol indicates lead free solder  and is attached on the PWBs and service manuals  The  alphabetical character following LF shows the type of lead free solder     Example     Using lead free wire solder         When fixing the PWB soldered with the lead free solder  apply lead free wire solder  Repairing with conventional lead wire solder may cause dam   age or accident due to cracks     As the melting point of lead free solder  Sn Ag Cu  is higher than the lead wire solder by 40 C  we recommend you to use a dedicated soldering  bit  if you are not familiar with how to obtain lead free wire solder or soldering bit  contact our service station or service branch in your area     Soldering         As the melting point of lead free solder  Sn Ag Cu  is about 220 C which is higher than the conventional lead solder by 40
2.     NEW  MARK    PART  DELIVERY  DESCRIPTION     1  PRINTED WIRING BOARD ASSEMBLIES    N  DUNTKF111FM08  CB  P  MAIN Unit  B3KU2H57CG     N  DUNTKF115FM02  AH  P  LED Unit  B3KU2H57CJ     N  DUNTKF069FM05  AP  P  KEY Unit  B3KU2A47CK     N  DUNTKF063FM01  BH  V  POWER Unit    N  DUNTKF071FM04  BF  V  INVERTER Unit    N  RUNTKA561WJZZ  N  P  LCD CONTROL Unit    N  RUNTKA550WJZZ  AR  V  GND PWB Unit     2  LCD PANEL    N  R1LK315T3GW40Y  CQ  P  32  LCD Panel Module    LC 32DH57E GY RU GY S GY    BK    3     3  CABINET AND MECHANICAL PARTS    1    22    25    26    2 1    2 2    2 4    2 2    2 2    2 2    4 1    4 2    4 3    33    7    34    2    32    1 4    27    32    34    35    5    1 1    29    28  1 3    1 2    10    10    9    8    4    35    21    24    35    15    34    34    3 2  3 1    6    35    17    12    18    19    20    35  11    35    16    30    31    23    3    31    36    LC 32DH57E GY RU GY S GY    14    37    2 3    2 3    4    NO   PARTS CODE  PRICE  RANK    NEW  MARK    PART  DELIVERY  DESCRIPTION     3  CABINET AND MECHANICAL PARTS    1  CCABAC243WJ08  N  P  Front Cabinet Ass y    1 1  Not Available     N     Front Cabinet    1 2  Not Available     N     LED Cover    1 3  Not Available     N     Decoration    1 4  XEBS730P08000  AA  J  Screw    2  CCABBB470WJ01  BA  N  P  Rear Cabinet Ass y    2 1  Not Available     N     Rear Cabinet    2 2  Not Available        VESA Holder  x4    2 3  Not Available     N     Spacer  0 5x10x30   x6    2 4  XEBS730P0
3.   Operation Manual  for Russia     X13  TiNS E057WJZZ  AH  N  P  Operation Manual  for Northern Europe     X14  TiNS E058WJZZ  AK  N  P  Operation Manual  for East Europe     X15  Not Available         AA  Size Battery    X3  X2  X1  X1 1 X1 2    X11 X12 X13 X14  X15    LC 32DH57E GY RU GY S GY    BC    6     5  PACKING PARTS  NOT REPLACEMENT ITEM     S8    S7    S2    S1    S7    S10    S7    S7    S3  S4  S6  S9    LC 32DH57E GY RU GY S GY    S5    7    NO   PARTS CODE  PRICE  RANK    NEW  MARK    PART  DELIVERY  DESCRIPTION     5  PACKING PARTS   NOT REPLACEMENT ITEM     S1  SPAKCE791WJZZ     N     Packing Case    S2  SPAKAA373WJZZ        Cover Sheet    S3  SPAKFB838WJZZ     N     Mirror Mat Sup    S4  SPAKFB732WJZZ     N     Stand Case    S5  SPAKPA382WJZZ        Wrapping Paper    S6  SPAKPB304WJZZ        Mirror Mat Base    S7  SPAKXC379WJZZ     N     Packing Add     S8  SSAKAA111WJZZ        Polyethylene Bag    S9  SSAKHA049WJZZ     N     Polyethylene Bag  for Screw     S10  TLABM5584BMZZ        No  Label     6  SERVICE JIGS    N  QCNW G616WJQZ  BK  J  Connecting Cord Main   LCD Control  LW     N  QCNW H347WJQZ  AY  J  Connecting Cord Main   LCD Control  LP     N  QCNW J413WJPZ  AQ  J  Connecting Cord Main   Speaker  SP     N  QCNW J415WJPZ  AT  J  Connecting Cord Main   Key LED  RA KM     N  QCNW J416WJQZ  CE  J  Connecting Cord LCD   LCD Control    N  QCNW J835WJQZ  AY  J  Connecting Cord Main   Power  PD LB     LC 32DH57E GY RU GY S GY    COPYRIGHT    2009 BY SHARP COR
4.  C  and as it has poor  solder wettability  you may be apt to keep the soldering bit in contact with the PWB for extended period of time  However  Since the land may be  peeled off or the maximum heat resistance temperature of parts may be exceeded  remove the bit from the PWB as soon as you confirm the  steady soldering condition     Lead free solder contains more tin  and the end of the soldering bit may be easily corroded  Make sure to turn on and off the power of the bit as  required     If a different type of solder stays on the tip of the soldering bit  it is alloyed with lead free solder  Clean the bit after every use of it     When the tip of the soldering bit is blackened during use  file it with steel wool or fine sandpaper          Be careful when replacing parts with polarity indication on the PWB silk     Lead free wire solder for servicing    L F a    Indicates lead free solder of tin  silver and copper     L F a a    Indicates lead free solder of tin  silver and copper     Part No   Description  Code    ZHNDAi123250E  J  0 3mm 250g  1roll   BL    ZHNDAi126500E  J  0 6mm 500g  1roll   BK    ZHNDAi12801KE  J  1 0mm 1kg  1roll   BM    LC 32DH57E GY RU GY S GY    iii    LC19D1RU BK  Service Manual    OUTLINE AND MODIFIED PARTS LIST    OUTLINE    MODIFIED PARTS LIST    Ref  No   Description     Base Models     LC 32DH57E BK RU BK S BK     These Models   Remarks    PRINTED WIRING BOARD ASSEMBLIES  N  MAIN Unit  DUNTKF111FM08  No Change    N  LED Unit  DUNTKF115FM02  
5.  SERVICE MANUAL    LC 32DH57E GY RU GY S GY    No  S79B1LC32DH57    Parts marked with      are important for maintaining the safety of the set  Be sure to replace these parts with specified ones for maintaining the    safety and performance of the set     This document has been published to be used for  after sales service only   The contents are subject to change without notice     SAFETY PRECAUTION    IMPORTANT SERVICE SAFETY PRE   CAUTION                                                            i  Precautions for using lead free solder                ii    OUTLINE AND MODIFIED PARTS LIST    OUTLINE                                                           iii  MODIFIED PARTS LIST                                    iii    Parts Guide    TopPage    CONTENTS    LCD COLOUR TELEVISION    LC 32DH57E GY  LC 32DH57RU GY  LC 32DH57S GY  MODELS    In the interests of user safety  Required by safety regulations in some countries  the set should be restored to its orig   inal condition and only parts identical to those specified should be used     This Service Manual covers the differences from LC 32DH57E BK RU BK S BK or other technical information  refer to  the   No  S59Z3LC32DH57  Service Manual     OUTLINE    LC 32DH57E BK RU BK S BK    i    LC19D1RU BK  Service Manual    SAFETY PRECAUTION    IMPORTANT SERVICE SAFETY PRECAUTION    WARNING    1  For continued safety  no modification of any circuit should be    attempted     2  Disconnect AC power before servicing     BEFORE RETU
6.  checks    Any reading of 1 05 V peak  this corresponds to 0 7 mA peak AC    or more is excessive and indicates a potential shock hazard which  must be corrected before returning the monitor to the owner                                                                                                                                                                                                                                                    SAFETY NOTICE    Many electrical and mechanical parts in LCD color television have  special safety related characteristics     These characteristics are often not evident from visual inspection  nor  can protection afforded by them be necessarily increased by using  replacement components rated for higher voltage  wattage  etc     Replacement parts which have these special safety characteristics are  identified in this manual  electrical components having such features    are identified by          and shaded areas in the Replacement Parts    List and Schematic Diagrams     For continued protection  replacement parts must be identical to those  used in the original circuit     The use of a substitute replacement parts which do not have the same  safety characteristics as the factory recommended replacement parts  shown in this service manual  may create shock  fire or other hazards                                                                                                                                                               
7. 8000  AA  J  Screw  for VESA   x4    3  CANGKC130WJ01  AK  P  Terminal Angle Ass y    3 1  Not Available        Terminal Label    3 2  Not Available        Terminal Angle    4  CANGKC165WJ02  AS  N  P  Stand Angle Ass y    4 1  Not Available     N       Support Angle  4 2  Not Available     N       Bottom Angle    4 3  Not Available     N     Screw  4x55   x4    5  JBTN A812WJ1A  AE  N  P  Control Button    6  LANGKC138WJFW  AF  N  P  AC Inlet Angle    7  LHLDFA036WJKZ  AB  J  Wire Holder  x4    8  LHLDWA143WJKZ  AC  J  Wire Holder    9  LHLDWA175WJUZ  AC  J  Wire Holder    10  LX HZA003WJFN  AC  J  Screw  for Speaker   x2    11  NSFTZA243WJFN  AB  J  Shaft  x4    12  PSLDMB578WJFW  AL  N  P  Main PWB Shield    14  PSPAKA423WJKZ  AA  N  P  Spacer  0 3x3x8     15  PSPANA032WJKZ  AC  J  Spacer  for PWB     16  QCNW J026WJQZ  AH  J  Connecting Cord  KM     17  QCNW J088WJQZ  AK  J  Connecting Cord    18  QCNW J206WJQZ  AH  N  P  Connecting Cord  LP     19  QCNW J207WJQZ  AY  N  P  Connecting Cord  LW     20  QCNW J208WJQZ  AK  N  P  Connecting Cord  LB     21  QCNW J211WJQZ  AG  N  P  Connecting Cord  x2    22  QCNW J550WJPZ  AH  N  P  Connecting Cord  SP     23  QEARPA339WJFW  AC  P  Earth Plate    24  RCORFA064WJZZ  AE  P  Core  for LCD FFC   x2    25  RSP ZA391WJZZ  AP  J  Speaker L    26  RSP ZA392WJZZ  AP  J  Speaker R    27  TLABNC117WJZZ  AA  P  Model Label    28  TLABZB406WJZZ  AC  P  ECO Label  for Europe     29  TLABZC169WJZZ  AF  N  P  POP Label  for Europe     29  TL
8. ABZC170WJZZ  AF  N  P  POP Label  for Russia     30  XBBS730P04000  AA  J  Screw  for Tuner     31  XBPS830P06000  AA  J  Screw  for HDMI   x3    32  XEBS730P08000  AA  J  Screw  x2    33  XEBS740P16000  AA  P  Screw  for Rear Cabinet   x9    34  XEBSN40P10000  AB  N  J  Screw  for LCD Module   x6    35  XHPS730P06WS0  AA  J  Screw  for PWB Angle   x25    LC 32DH57E GY RU GY S GY    36  PSPAKA425WJKZ  P  Spacer  for RS232C Terminal   N    37  XHPS730P08WS0  AA  J  Screw  for Rear Cabinet   x3    AV    BD    5     4  SUPPLIED ACCESSORIES    NO   PARTS CODE  PRICE  RANK    NEW  MARK    PART  DELIVERY  DESCRIPTION     4  SUPPLIED ACCESSORIES    X1  CDAi A542WJ08  N  P  Stand Unit    X1 1  Not Available     N     Stand Base    X1 2  Not Available     N     Screw Ass y       X2  QACCKA024WJPZ  AP  P  AC Cord  except U K  and Ireland        X2  QACCBA073WJPZ  AS  P  AC Cord  for U K  and Ireland     X3  RRMCGA779WJSA  AQ  N  P  Remote Control Unit    X4  TCAUSA034WJZZ  AA  P  Caution Sheet  for East Europe     X5  TCAUZA222WJN1  AB  P  Caution Card  for Europe     X6  TGAN A801WJZZ  AB  P  Warranty Card  for U K  and Ireland     X7  TGAN A077WJZZ  AE  J  Warranty Card  for Russia     X8  TGAN B078WJZZ  AB  P  Warranty Card  for East Europe     X9  TGAN B079WJZZ  AB  P  Warranty Coupon  for East Europe     X10  TGAN A802WJZZ  AB  P  AQUOS_Card Plan  for U K  and Ireland     X11  TiNS E056WJZZ  AG  N  P  Operation Manual  for Europe except East Europe     X12  TiNS E059WJZZ  AC  N  P
9. No Change    N  KEY Unit  DUNTKF069FM05  No Change    N  POWER Unit  DUNTKF063FM01  No Change    N  INVERTER Unit  DUNTKF071FM04  No Change    N  LCD CONTROL Unit  RUNTKA561WJZZ  No Change    LCD PANEL  N  32  LCD Panel Module  R1LK315T3GW40Y  No Change    CABINET PARTS  Refer to Parts List     SUPPLIED ACCESSORIES  Refer to Parts List     PACKING PARTS  Refer to Parts List     Service Jigs  No Change    LC 32DH57E GY RU GY S GY    N  GND PWB Unit  RUNTKA550WJZZ  No Change    DUNTKF111FM08  DUNTKF115FM02  DUNTKF069FM05  DUNTKF063FM01  DUNTKF071FM04  RUNTKA561WJZZ    R1LK315T3GW40Y    RUNTKA550WJZZ    This Service Manual covers the differences from LC 32DH57E BK RU BK S BK or other technical information  refer to  the   No  S59Z3LC32DH57  Service Manual   LC 32DH57E BK RU BK S BK    LC 32DH57E GY RU GY S GY    PARTS GUIDE    Parts marked with      are important for maintaining the safety of the set  Be sure to replace these    parts with specified ones for maintaining the safety and performance of the set     This document has been published to be used  for after sales service only   The contents are subject to change without notice      1   PRINTED WIRING BOARD  ASSEMBLIES     2   LCD PANEL     3   CABINET AND MECHANICAL     4   SUPPLIED ACCESSORIES     5   PACKING PARTS    CONTENTS    LCD COLOUR TELEVISION    No  S79B1LC32DH57    LC 32DH57E GY  LC 32DH57RU GY  LC 32DH57S GY  MODELS    LC 32DH57E GY RU GY S GY    PARTS     6   SERVICE JIGS    2    NO   PARTS CODE  PRICE  RANK
10. PORATION    ALL RIGHTS RESERVED     No Part of this publication may be reproduced   stored in a retrieval system  or transmitted in  any from or by any means  electronic  mechanical   photocopying  recording  or otherwise  without  prior written permission of the publisher     SHARP CORPORATION  AV Systems Group  CS Promotion Center  Yaita Tochigi 329 2193  Japan    July  2009  YT    LC 32DH57E GY RU GY S GY    
11. RNING THE RECEIVER     Fire  amp  Shock Hazard     Before returning the receiver to the user  perform the following  safety checks     3  Inspect all lead dress to make certain that leads are not pinched     and check that hardware is not lodged between the chassis and  other metal parts in the receiver     4  Inspect all protective devices such as non metallic control knobs     insulation materials  cabinet backs  adjustment and compartment  covers or shields  isolation resistor capacitor networks  mechanical  insulators  etc     5  To be sure that no shock hazard exists  check for leakage current in    the following manner          Plug the AC cord directly into a 220 240 volt AC outlet          Using two clip leads  connect a 1 5k ohm  10 watt resistor paral   leled by a 0 15 F capacitor in series with all exposed metal cabinet  parts and a known earth ground  such as electrical conduit or elec   trical ground connected to an earth ground          Use an AC voltmeter having with 5000 ohm per volt  or higher  sen   sitivity or measure the AC voltage drop across the resistor          Connect the resistor connection to all exposed metal parts having a  return to the chassis  antenna  metal cabinet  screw heads  knobs  and control shafts  escutcheon  etc   and measure the AC voltage  drop across the resistor   All checks must be repeated with the AC cord plug connection  reversed   If necessary  a nonpolarized adaptor plug must be used  only for the purpose of completing these
    