Home
Alliant Energy - Gas Service Rules
Contents
1. Gas Service Manual Appendix A Page 4 of 8 yA ALLIANT at ENERGY CUSTOMER PIPING MATERIAL SPECIFICATIONS CONTINUED Flanges Type Threaded Size 3 4 Material Forged Steel Rating ANSI 150 class preferred minimum ANSI 125 Flanges must meet requirements of ANSI B16 5 and MSS SP44 Note These minimum flange requirements apply to any customer flange that will meet up with a flange on the Company side piping All other flanges on customer piping must meet the requirements of ANSI B16 1 B16 20 or MSS SP 6 per NFPA 54 Section 5 6 10 Flex Connectors Approved Flexible connectors which meet NFPA 54 Section 9 6 and ANSI 221 75 Manufacturer Trade Name Dormont Super Safe BrassCraft ProCoat Tru Flex Home Flex Wrapping Coating Black Pipe Following item ID is for internal use only when ordering wrapping coating Item ID Description 103426 TAPE CORROSION 2IN 10MIL BLK P Base primer is recommended 3M Scotchrap Professional Grade Pipe Primer EXTERNALLY All weather performance and corrosion resistance pipe wrap tape 10 or 20 mil black tape with pvc backing resistant to impact and abrasions Suggested places to purchase Menards and The Home Depot Pro Pak pipe wrap tape available to special order from store or online at menards com or homedepot com Z E Specialty Plumbing supply stores PlumBest Online at shop3m com and other online specialty stores If you hear see or smell l
2. For SI units 1000 Btu hr 0 293 W 1 gal 3 8 L If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268 Gas Service Manual Appendix A Page 3 of 8 yA ALLIANT at ENERGY CUSTOMER PIPING MATERIAL SPECIFICATIONS The manufacturers listed below provide gas materials that are considered acceptable by the Company This list does not include all manufacturers that meet these criteria but is intended to provide a sample of sources from which acceptable gas materials can be obtained Valves All customer provided valves must be rated at the pressures listed below Threaded Valves 12 34 1 1 1 4 2 Valve gas plug non insulating threaded material is cast iron or ductile iron tamperproof minimum working pressure 100 psig rated for natural gas Manufacturer A Y McDonald Rockford Eclipse Mueller Flanged Valves 2 3 4 Valve gas plug flanged minimum ANSI 125 rated working pressure 200 psig wrench operated material is cast iron ductile iron or steel rated for natural gas Manufacturer Nordstrom Flowserve Resun Walworth Corrugated Stainless Steel Tubing CSST Pipe Manufacturer Ward Manufacturing Omegaflex Gastite Parker Hannifin Corporation Tru Flex Metal Hose Metal Fab Inc Under Ground Risers Manufacturer Perfection If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268
3. Estimated Date Permanent Gas Service Will Be Needed MM DD YY Delivery Pressure Needed 1 4 psi 7 water column wc e lbs per square inch psi Natural Gas Equipment Heating Quantity Water Heater Quantity Range Quantity Dryer Quantity Instantaneous nti Other Generator Pool uantit Quantity Q y Water Heater Heater etc BUILDING SITE SKETCH AND METER LOCATION REQUIREMENTS Customer must include a building site sketch with this application and mark the following information on the map 1 Mark a G for your proposed gas meter location with a measurement from the nearest corner of the dwelling 2 Mark an E for your proposed electric meter socket pedestal location with a measurement from the nearest corner of the dwelling 3 Show all decks pools wells septic underground tanks fuel lines drain tiles downspouts customer owned wires sprinkler systems yard lighting etc ITEMS ALLIANT ENERGY WILL NEED PRIOR TO SERVICE INSTALLATION CONNECTION Type an X in the following boxes to ensure the steps have been completed If they do not apply to your installation type N A in the box 1 Application filled out completely and signed 2 Sketch of customer owned facilities included with e 3 Payment of construction charges if applicable application 4 Electric gas route within 6 inches of final grade and clear of 5 Recorded copy of certified survey map or platted 6 Appropriate inspection form or statement tur
4. to the Company the right to clear for installation and maintenance of its overhead and or underground electric line or gas piping and to use any necessary equipment in on and across the above described b The applicant s jointly with other applicants on the same extension shall without cost to the Company maintain a right of way which the Company has the right to clear adequate for the extension and along a route approved by the Company c If requested by the Company the applicant s landowner shall grant to the Company an easement in recordable form conveying the rights and privileges in a and b above If applicant is not the Landowner the applicant is responsible for obtaining the e 3 IOWA ONLY The applicant s do es hereby certifies that the structure served by the gas and or electric service line if completed after April 1 1984 and if intended primarily for human occupancy conforms to the energy conservation requirements ado 4 The applicant s individually and jointly agree s to indemnify and hold harmless the Company from all claims against the Company because of any injury disease or death sustained by reason of any act omission or negligence of the applicant or any age 5 This agreement shall become effective when acceptance of the application has been signed on behalf of the Company 6 The Company agrees to return any deposit with interest according to the rules and regulations of the applicable State Regulatory
5. Authority 12 months from the date of this application unless 1 the customer s service has been disconnected within that ti 7 WISCONSIN ONLY The applicant s acknowledge s the right to make written request to the Company that the County Department of Health and Social Services be notified at least 5 calendar days prior to a scheduled disconnection of service for rule violat 8 The customer is responsible for notifying the Company of contaminated media soil groundwater etc that may be present on the premises prior to Company commencing installation or extension of service The Company reserves the right to consider alterna 9 If contaminated media is encountered during the installation or extension of service the Company shall terminate the installation or extension of service and notify the customer The customer is responsible for reporting the discovery of contamination to 10 The residential service customer charge on file with the State Regulatory Authority may be billed to the applicant beginning on the date the meter is installed 11 If a customer requests a gas pressure change 6 to 2 lbs or if a customer needs to increase meter size 250 to a 425 they will be charged the cost for Alliant Energy personnel to make the change 12 Failure to Consume Natural Gas a The applicant s agree s to begin consuming natural gas within 6 months of installation of the service lateral If the applicant is not consuming gas by that time the ap
6. Gas Service Manual Appendix A yA ALLIANT at ENERGY Page 1 of 8 Alliant Energy Gas Service Manual Appendix A Issued 2012 Supersedes 2009 APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES Appliance Space Heating Units Warm air furnace Single family Multifamily per unit Single family Multifamily per unit Space and Water Heating Units Hydronic boiler Single family Multifamily per unit Water Heating Appliances Water heater automatic storage 30 gal to 40 gal tank 50 gal tank Water heater automatic instantaneous Capacity at 2 gal min Capacity at 4 gal min Capacity at 6 gal min Water heater domestic circulating or side arm Cooking Appliances Range freestanding domestic Built in oven or broiler unit domestic Built in top unit domestic For SI units 1000 Btu hr 0 293 W 1 gal 3 8 L Input Btu hr Approx 100 000 60 000 100 000 60 000 120 000 75 000 35 000 50 000 142 800 285 000 428 400 35 000 65 000 25 000 40 000 If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268 Gas Service Manual Appendix A Page 2 of 8 y 4 ALLIANT at ENERGY APPROXIMATE GAS INPUT FOR TYPICAL APPLIANCES CONTINUED __ Appliance spt Btuhhr Approx gt S Other Appliances Refrigerator 3 000 Clothes dryer Type 1 domestic 35 000 Gas fireplace direct vent 40 000 Gas log 80 000 Barbecue 40 000 Gas light 2 500
7. and Light Company and Wisconsin Power and Light Company are Alliant Energy companies FOR OFFICE USE ONLY Date Received Electric WR No Gas WR No Customer Account No Alliant Energy Representative Work Phone No Map Location HOME OWNER AND SITE INFORMATION Home Owner Name Lasi First MI Social Security No Home Phone No Cell Phone No Work Phone No Fax No E mail Address as Town ka check one and enter name Subdivision Name Lot No an Square Footage of Dwelling Footage of Dwelling El Type BILLING INFORMATION Who should be billed for electric gas installation Who should be billed for electric gas usage during construction __ Builder __ Building Owner _ Builder ee Building Owner CONTRACTOR INFORMATION Builder Contractor Name Contact Person Name Federal Tax D No Home Phone No Cell Phone No Work Phone No Fax No E mail Address Electrical Contractor Work Phone No Cell Phone No Heating Contractor Work Phone No Cell Phone No ELECTRIC SERVICE REQUIREMENTS Date Permanent Electric Service Needed MM DD YY Date Temporary Electric Service Needed MM DD YY Service Amps Service Type Voltage Joo J200 __ s00 __Jother Jovernead Underground _ 120 240 _ Jother Electric Equipment Locked Electric Jwater Quantity Central Ground Source Rotor Amps __ other Hot Heat Heater A C Heat Pump LRA Tubs etc GAS SERVICE REQUIREMENTS
8. eaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268 Gas Service Manual Appendix A Page 5 of 8 qs a ALLIANT ENERGY CONVERSION CHART ENERGY CONVERSION FACTORS 1 Cf Cubic Feet Approximately 1 000 Btu C Hundred 1 Cef 100 Cf 1 Therm M Thousand 1 Therm 100 000 Btu 100 Cf 0 1 Mcf MM _ Million 10 Therms 1 Mcf 1 MMBtu Dth Dekatherm 1 Mcf 1 000 Cf 10 Ccf 10 Therms 1 Dth 1 Quad 10 Mcf 10 Therms 10 Btu Comparative 1 00 24 0 0 0916 0 125 0 139 0 150 0 003412 Thermal million million million million million million million Values Btu Btu Btu Btu Btu Btu Btu Natural Gas 1 000 24 000 91 600 m 7 m 150 000 3 412 1 000 Cf Cf Cf Cf Cf Btu Cf Coal 83 2 7 10 11 12 500 0 2843 12 000 lb Ib Btu Ib Propane 10 917 262 009 1 365 1 517 1 638 0 0373 91 600 Gal Gal Gal Gal Gal Gal Btu Gal Gasoline a 000 ia 000 ca 733 1 112 1 200 0 0273 3 Gai ka ca 5 zaje Btu Gal Fuel Oil 2 7 194 172 662 0 659 0 899 1 079 0 0245 139 000 Gal Gal Gal Gal Gal Gal Btu Gal Fuel Oil 6 6 666 160 000 0 611 0 833 0 927 l 0 0277 150 000 Gal Gal Gal Gal Gal Gal Gal Btu Gal Electricity 293 083 7 033 998 26 846 36 635 40 739 43 962 l 3 412 Kwh Kwh Kwh Kwh Kwh Kwh Kwh Btu Kwh If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268 Gas Service Manual A
9. ned all obstructions lumber machinery etc lot and lot corners staked into Alliant Energy for gas and electric utilities ie _ 7 Expose or locate with staking flagging and or other durable 8 Other marking the physical location of any customer owned underground facilities i e wells septic underground tanks fuel lines drain tiles downspouts customer owned wires sprinkler systems Alliant Energy and or its agent will not be held responsible for damage occurring to customer owned underground facilities that are not properly located and marked before the installation of electric and or natural gas service 75 0507 ELECT ECRM158843 01407 If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268 Gas Service Manual Appendix A Page 8 of 8 yA ALLIANT aan ENERGY RESIDENTIAL ELECTRIC AND NATURAL GAS SERVICE APPLICATION CONTINUED ALLIANT RESIDENTIAL ELECTRIC AND NATURAL GAS Pane 2 of 2 ENERGY SERVICE APPLICATION AND AGREEMENT Interstate Power and Light Company and Wisconsin Power and Light Company are Alliant Energy companies 1 The applicant s understand s and agree s that prior to installation of underground electric lines or gas piping the Landowner shall have established the final grade of the route and that after installation of the line the grade shall not be increased 2 Easement Right of Access a The applicant s if also the Landowner s grant s
10. on of any and all customer owned obstacles that lie underground within ten feet of proposed excavation Such obstacles include but are not limited to septic and sewer systems buried wires for out buildin APPROVAL AND ACCEPTANCE Ihave read and understand the terms and conditions above Owner Aesponsible Party Signature OwnerAesponsible Party Printed Name pe ACCEPTED BY APPLICABLE ALLIANT ENERGY COMPANY Alliant Energy Representive Signature Alliant Energy Representive Printed Name arene ROUTING ORIGINAL Return to Alliant Energy COPY Customer 75 0507 ELECT ECRM158843 0107 END If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268
11. plicant agrees to pay each month the Residential Service Customer Charge on file wi b Ifthe applicant s do es not begin consuming gas within ten years of the installation of the service lateral the applicant shall be liable for service pipe removal costs After the service lateral has been installed the applicant s may not avoid obligations under these agreements by requesting discontinuance of service or by requesting service under a different rate schedule d This agreement obligates the applicant s heirs successors and assignees This agreement may not be assigned to a tenant or future purchaser of the premise 13 The Company agrees to furnish and and the Customer agrees to take and pay for utility service in accordance with provisions and rates approved by the State Regulatory Authority subject to all applicable rules of the Company on file with the State Regula TRENCH MARKING AGREEMENT The Customer agrees that the Company will dig trench plow or bore on the customer s property located at the above address for the installation of utility service Utility rates are based on rough grade construction meaning the Company will backfill and Prior to digging trenching or boring the company will identify the route of the proposed excavation The Company will notify other utility owners to facilitate the marking of existing underground utilities including electric telephone and cable TV The Customer agrees to physically mark the locati
12. ppendix A Page 6 of 8 7 4 ALLIANT ENERGY GAS PIPING STATEMENT SAMPLE a ALLIANT ENERGY GAS PIPING STATEMENT Interstate Power amp Lightand Wisconsin Power amp Lightare Customer Name Alliant Enemy Companies Tax District Work Request Mo Owner of Premises U Same as above OF Contractor Name Gas Piping Installers Name Phone Ma TYPE OF 7 N APPLIANCES CONNECTED E SERVICE H Residence m New Piping I Furnace check CI Commercial L Existing Piping h a pnn CT Industrial EJ Manufactured Home T Tankless Water Heater Po 1 Converted Piping Range LJ Dryer J Fireplace Other a DELIVERY PRESSURE Orwe C2 psig The undersigned states the above pipin was completed or converted for natural gas service and was Inspected and pressure tested on the premises described above according to applicable codes and that the gas piping complies with the provisions of all applicable codes and Alllant Energy service rules PRESSURETEST DATE Required Month Day Year Signature 75 0621 ECRM158958 REV 3 1008 FROM Alliant Energy If you hear see or smell leaking natural gas call Alliant Energy at 1 800 ALLIANT 1 800 255 4268 Gas Service Manual Appendix A Page 7 of 8 7 4 ALLIANT ENERGY RESIDENTIAL ELECTRIC AND NATURAL GAS SERVICE APPLICATION SAMPLE it ALLIANT RESIDENTIAL ELECTRIC AND NATURAL GAS Page 1 of 2 ENERGY SERVICE APPLICATION AND AGREEMENT Interstate Power