IGB/IGX Series (Overseas Specifications) Service Manual

image

Contents

1. 10 12 13 4 2 15kg 6kg 0 005kg 0 002kg Dual Range 7 6kg 3kg 0 002kg 0 001kg Dual Range 3 60009 3000 29 19 Dual Range 6 30000 1500 19 0 59 Dual Range 7 150kg 150k 0 1kg 0 05kg Dual Range Fishery specification 150kg 0 05kg 1 3000 Single Range Body weight specification 30kg 0 01kg 1 3000 Single Range Baby scale specification 2 60Ib 30kg 1 3000 Multi Interval Individual scale settings 20 21 22 23 24 25 m 30 31 CD 1 By setting the Scale No the scale will function according to default data of addresses 110 and 111 2 The above data determines each specification so changing the data is prohibited 3 Data A indicates the upper position of the one byte data and B indicates the lower position Ref Refer to Weighing Condition Data Table for data details i f Manual No 085 3435 07 1345 IGB GX Series Overseas Specifications Service Manual 2 2 3 Operation Procedure Operation Display 1 Starting Test Mode C1 Press ON OFF Press and hold while all segments are lit Press SET 2 Setting Country Number To increase the number press ZERO decrease the number press Press Example Asia 3 3 3 Setting Scale Number When setting 60kg select 08 Press SET 4 Selecting Weight at Span Adju
2. e Enio nia 31 3 2 1 IGB Block DIAagratm so ii tere eot tele e rade E 31 3 2 2 Board PS 018 eter Neh atin t ae lon Ho d 32 3 2 3 Power Board PS 019 nee etre tee ren pat eee ER e lE nea Le re eo ER SR De nnn 33 3 3 Electric Parts IGX Serles based 34 3 3 1 IGX Block Diagram RE 34 3 22 Main Board PS 0106 x diee eid bec ee ite ee ec ane 35 CHAPTER 4 2 5 6 lt Ee ru RR uda 37 4 1 Disassembly Procedure for Display Unit emen enne 37 4 2 Replacement of Main Board pp 38 4 2 1 e ASI nte REN 38 4 2 2 IGX UU mS 39 4 3 X Replacing and Adjusting Load Ce 41 4 3 1 Checking and Adjusting Gap of Four corner Limit sse 42 4 3 2 Performing Zero Point and Span Adjustments RN 43 4 4 Troubleshooting keen ieri er tenet ce tet ee c Pet e ee geld ene ee e nee 44 Manual No 085 3435 07 145 IGB IGX Series Overseas Specifications Service Manual OUTLINE e Purpose of this manual e This manual is to be used as a reference for the maintenance servicing of IGB or IGX series Related manual e For placing the product mounting the display pole setup mode and setup values refer to the operation manual e Symbols in the description 1 Warning symbols Indicates informa
3. KEY 0 indicates that there is no key entry 4 Checking Keys 2 1 TARE 2 f SET 4 EXT INPUT 5 MEMORY SW 4 5 Finishing Procedure Press ON OFF to finish this procedure ms i OFF status 2 4 Mode Display Check 1 Simplified Check Operation Display 1 Starting Test Mode C1 Press ON OFF r i Press and hold ZERO while all segments are lit L 2 Entering C3 Mode Press ZERO twice es i 3 Checking Displays Press HHRH The display shows self diagnostic check 00000 11111 122 428 V 4 Returning to Test Mode Press COLUMN to return to Test Mode Manual No 085 3435 07 19 45 IGB GX Series Overseas Specifications Service Manual 2 5 C4 Mode Display Check 2 Detailed Check Operation 1 Starting Test Mode C1 Press ON OFF Press and hold ZERO while all segments are lit 2 Entering C4 Mode Press ZERO three times 3 Checking Displays Press SET The display shows self diagnostic check 4 Returning to Test Mode Press COLUMN to return to Test Mode 2 6 C5 Mode Program No Display Operation 1 Starting Test Mode Press O
4. LOAD CELL LOC ISS10 300kg 900 0816 05 Note Part numbers may change without notice due to product improvements Manual No 085 3435 07 28 45 j m L iPmMN N lm iiN IGB GX Series Overseas Specifications Service Manual Series Service Parts List Part Name CASE FRONT Remark 900 0756 05 CASE REAR TRANSFORMER 900 0757 09 COVER BATTERY 900 0754 08 BRACKET 900 0725 00 BRACKET DISPLAY 900 07 26 03 PLATE EARTH 900 0727 07 BRACKET CASE 900 0829 03 WASHER RUBBER 900 0748 05 FILTER DISPLAY 900 0755 01 SHEET DISPLAY SHEET DISPLAY Varied per country Varied per country SHEET AC ADAPTER 900 0770 08 NAME PLATE SPEC Varied per country NAME PLATE SPEC Varied per country PWB PS 016 TRANSFORMER ASSY 900 0676 01 900 1697 02 CABLE LOCKING PG 11 900 0758 02 HARNESS 52 GND 900 0772 05 HARNESS C3 POWER CORD Varied per country SHEET 900 1064 05 SIDE COVER 900 0037 11 POLE STAND 900 0032 49 RUBBER RING 900 0207 07 PLATTER 072 8847 05 SHEET PLATTER 900 0100 02 PLATE SUPPORT 900 0021 11 BASE 900 0020 35 FOOT LEVEL 900 0022 05 PLATE A LEVEL 900 0222 03 L
5. 085 3435 07 9 45 IGB IGX Series Overseas Specifications Service Manual 2 1 3 Test Mode Flow a e each C1 mode setup coun ZERO a TARE C2 Key check ZERO Each mode C3 to C6 operation LIS function COLUMN ZERO JE TARE pL Each mode operation COLUMN TARE C8 C9 2 1 4 Key Functions Key Function Turns the power ON or OFF for the IGB Series Turns the power ON or OFF for the IGX Series 5V is always supplied to the circuit voltage ZERO Increases the numeric value when the numeric value is set Advances the mode when conditions are set Adjusts the zero point TARE Decreases the numeric value when the numeric value is set Reverses the mode when conditions are set Adjusts the span point u Determines the data in the Details Mode 2 Changes between Adjust ZERO lt key display and Adjust TARE key d display when the span is adjusted Returns to each mode switch Tact switch on the main board Saves the E2ROM data of each item setting of C1 mode Manual 085 3435 07 IGB GX Series Overseas Specifications Service Manual 10 45 2 1 5 Mode List Wo ae 2 1 Country No Scale No Zero point Span adjustment C2 Key check Display check 1 simplified check All LEDs light up Display check 2 detailed check Each segmen
6. 110 to 115 Weighing condition setting data condition setting table p 2 DENEN 121 to 123 A D calibration data adwidth 24 bit 4 capacity setting Refer to Capacity setting 00 to 99 125A JAPAN onl oor 125B Span adjusted flag 5H or others as 126 127 Check sum from 100 to 113 Po Default 1 60kg Manual No 085 3435 07 25 45 IGB GX Series Overseas Specifications Service Manual 2 10 C9 Mode Board Inspection A D Check I F Check This mode is for factory inspection and shall not be used for maintenance Operation Display 1 Starting Test Mode r Press ON OFF f I Press and hold while all segments are lit 2 Entering C9 Mode Press ZERO eight times gq Or press TARE 3 Press SET f Span adjusted A D data is displayed G 7 4 Press SE A D converter output value is displayed 4 However the lower bits of 24 bit output change rapidly and lt 4 are outside of visual inspection range so they excluded 5 Press ZERO E H Used for A D board drift inspection a Kd 1 The inspection result is displayed OK or Err A lt gy A 6 Press TARE P I Connect the inspection jig and all I O ports are checked a ri ri 7 Press COLUMN to return to Key Test Mode hri Manual No 085 3435 07 26 45 IGB GX Series
7. 4 44 Troubleshooting The display does not appear when 1 AC power is not supplied Check the voltage of the main ON OFF is pressed IGX Series only power outlet Check the power cable and replace if necessary Each ON OFF key is shown below Check the FUSE 1A 250V for the IGB or IGX Series Check the TRANS ASSY Check the main board PS 016 b connector XJ2 er Battery voltage is low Check batteries and replace if IGB Series only necessary When using the AC adapter confirm that the adapter voltage is within the range of 3 2 to eVDC The ON OFF key is Using the tester check that the key defective is conducting and replace if necessary The main board is Replace the main board PS 016 defective IGX or PS 018 IGB with a normal one then check Err is displayed when the E2ROM data is garbled Initialize E2ROM all in Test Mode ON OFF key is pressed C6 Span adjustment is required after initialization If recovery is not possible the main board may be defective Replace if necessary Test mode C1 is displayed when Scale data is in initialized Perform span adjustment the ON OFF key is pressed state is displayed after the 1 A D value at Zero point is Remove items from the weighing ON OFF key is pressed and the outside of start range or platter display is checked unstable Check A D value and adjust Perform Test Mode C1 and if the Out of AD initial value value is
8. only for 8 communications 0 8 0 1 2 3 4 5 6 7 1 0 0 3 0 000 1 1 2 change in Dual range Multi Interval 2 2 5 10 change in Dual range Multi Interval 5 10 20 change Dual range Multi Interval Invalid 1 500 1 1 600 2 1 750 3 1 1000 1 1200 5 1 1500 6 1 2000 7 1 2500 1 3000 9 1 4000 1 5000 1 6000 1 7500 D 1 10000 1 12000 1 15000 Single range LED stable display only IGX 1 3000 Multi interval Stabe Upper Lower display IGB Single range Upper Lower display IGX 1 3000 Multi interval Stabe Upper Lower display IGB Single range Body weight specification 1 3000 Dual range A B range change Single range Ib kg change 1 3000 Multi interval Ib kg change 111A lt 111 gt 0 kg kg Ib 0 g 1 16 1 oz Filter setting Cut off Notch Output rate ANO Do not change the data 2 22 45 0 66Hz 2 50Hz 400ms 0 84Hz 3 20Hz 312ms 1 05Hz 4 00 2 250ms 1 31Hz 5 00Hz 200ms 1 68Hz 6 40Hz 156ms 2 10 2 8 00 2 125ms 2 62 2 10 00Hz 100ms 3 35Hz 12 80Hz 78ms IGB GX Series Overseas Specifications Service Manual lt lt _ lt Address Weight Item Data 112A Start width 1 50 2 of weighing capacity 1 25 4 of weighing capacity 1 10 410 of weighing capacity 1 7 5 413 3 of weighing capaci
9. 0VAC 57mA 120VAC 46mA 220VAC 28mA 240VAC 23mA Display LCD VFD Numerics 6 digits Height 25mm Numerics 5 1 2 digits Height 29mm Mark Battery Zero point Now subtracting Mark Zero point Now subtracting tare tare Stable Weight unit kgUb Over LED Under Accept Over Under Accept Tare Subtraction Key in tare Preset tare Preset Function Program Mode 10 PLUs from PLU 1 to PLU 10 Tare weight Upper limit Lower limit Upper Limit Range More than the lower limit within 5 digits 99999 Lower Limit Range Less than the upper limit 5 digits in case of the upper limit 0 Auto Power Off Setup Mode None 10min 20min 30min No 40min 50min 60min Auto Preset Call up Setup Mode Function Yes No selection PLU 1 is called up when the power is ON Battery Check Mode Yes N Buzzer No Setup Mode ON OFF Switch N Setup Mode Manual 085 3435 07 4 45 IGB IGX Series Overseas Specifications Service Manual 1 3 Appearance Series Asia Oceania Specification Display unit iy indicater Display pole Weighing platter Series Asia Oceania Specification Display unit indicater Weighing platter ML CN I Level adjuster Manual 085 3435 07 5 45 IGB IGX Series Overseas Specifications Service Manual 1 4 Display Unit Series Asia Oceania Specification WEI
10. 4 As for Weight a function is selected with 1 2 4 and 8 in bit unit and H indicates Hexadecimal data 5 Individual setting value 99 cannot be entered Displayed only when settings are changed in C7 6 USA 2 code is settings to allow changing between Ib and at anytime even in cases other Refer to Weighing Condition Data Table for detailed function selection mode than a stable condition at zero point USA 1 can change between Ib and kg only when the condition is stabilized at zero point When using this function a maximum of 0 2e error may occur in weighing immediately after the change This error is calibrated by zero point adjustment or zero tracking and an accurate weighing is guaranteed When selecting the weighing capacity exclusively for either Ib or kg use USA 1 Manual No 085 3435 07 12 45 IGB GX Series Overseas Specifications Service Manual 2 2 2 Scale No Table Address Scale No Specifications 110A 110B 111A 111B Default Data 150kg 0 05kg 0 02kg Multi Interval 30kg 0 01kg 0 005kg Multi Interval 15kg 0 005kg 0 002kg Multi Interval 7 6kg 0 002kg 0 001kg Multi Interval 60009 29 19 Multi Interval 30000 19 0 59 Multi Interval 7 120kg 0 02kg 1 6000 Single Range 60kg 0 01kg 1 6000 Single Range 15 30kg 0 01kg 1 3000 Single Range 2 16 19 30000 10 1 3000 Single Range
11. EVEL UNIT ASS 900 0315 15 BRACKET LEVEL 900 0010 01 LOAD CELL LOC ISS10 100kg 900 0815 01 LOAD CELL LOC ISS10 300kg 900 0816 05 Note Part numbers may change without notice due to product improvements Manual No 085 3435 07 20 45 IGB GX Series Overseas Specifications Service Manual 3 1 1 Load Cell Manual 085 3435 07 30 45 IGB IGX Series Overseas Specifications Service Manual 3 2 Electric Parts IGB Series 3 2 1 IGB Block Diagram Display Unit Main Board PS 018 AC Adaptor L Power Board PS 019 AC Adaptor JACK L Scale Unit Load Cell Manual 085 3435 07 31 45 Series Overseas Specifications Service Manual 3 2 2 Main Board PS 018 Parts Surface of Main Board The LCD and tact keys are installed on the soldering surface CPU AD CONVERTER OP AMP uPD78F9468 AD7714YR 0P177GP 1 SW1 Memory Switch Used to write the data when performing initialization in Test Mode Used to save write the data in E2ROM after changing Country No and Scale No and performing Span Adjustment 2 Connector XJ1 This connector is not used 6 NO 3 Connector XJ2 This connector is used for DC input Manual No 085 3435 07 32 45 IGB GX Series Overseas Specifications Service Manual 4 Connector XJ3 This connector is not used ee s Ro o4 TD Lo owe 5 Prog
12. GHT ui HO D HD NES STABLE ZERO UNDER ACCEPT OVER 150kg Min 1kg e 0 05kg 149 95 kg om l Y ISHIDA Series Asia Oceania Specification 150 kg Min 1 e 0 05 kg T 149 95 kg we I 1x 7 Manual 085 3435 07 6 45 IGB IGX Series Overseas Specifications Service Manual 1 5 Outer Dimensions gt 400 20 550 20 138 20 138 30 Unit mm Manual No 085 3435 07 7 45 IGB IGX Series Overseas Specifications Service Manual memo Manual 085 3435 07 8 45 IGB IGX Series Overseas Specifications Service Manual Chapter 2 Test Mode The Test Mode is used to check the machine when maintenance is performed or to perform settings 2 1 Operation The keys used in the following diagram are for Asia Oceania specifications For specifications for other countries use the corresponding keys 2 1 1 Starting Each Mode i Operation Manual Stat i Normal Mode V Scale ON Voltage Check Release IGE only ON OFF key Then press one of these keys Setup Mode while all segments are illuminated Program Mode Test Mode Press for 2 seconds or more 2 1 2 Ending Test Mode C1 Mode In Mod You cannot return to Cx mode C3 to C9 C3 to C9 In Mode Scale OFF Manual
13. N OFF Press and hold ZERO while all segments are lit 2 Entering C5 Mode Press ZERO four times 3 Displaying Program Number Press SET The installed program number D005 will be displayed 4 Returning to Test Mode Press COLUMN to return to Test Mode Manual No 085 3435 07 19 45 IGB GX Series Overseas Specifications Service Manual 2 7 C6 Mode RAM Clear and E2ROM Clear Operation Display 1 Starting Test Mode 1 Press f Press and hold ZERO while all segments lit 2 Entering C6 Mode ai Press ZERO five times dun LLEH 4 RAM Clear Preset data of Program Mode is cleared y H Press ZERO Press ZERO Y me ri h 5 Press COLUMN to return to Test Mode h E2ROM Clear Initializing E2ROM data 6 Press SET Push the Memory Switch SW1 located on the main board This does not work when there has been no data change C1 data and setting data FO1toF17 have been initialized Settings are required 8 Press ON OFF After initialization nothing except C1 will be displayed C1 data settings Country No Scale No Zero point Span adjustment are required Manual No 085 3435 07 20 45 IGB IGX Series Overseas Specifications Service Manual 2 8 C7 Mode Weigh
14. NM our a ee Name 3 _ 4 _ 5 Connector XJ2 Power Input Pin No Signal Name 1 12 2 3 wv 3 29C ae EE NC Non connection 4 5 6 ov CT Ac Manual 085 3435 07 35 45 IGB GX Series Overseas Specifications Service Manual 4 Connector XJ3 This connector is not used Pin No Signal Name 5 Program Memory Media e Mask ROM 256KB Writing or replacement is not possible There is no compatibility between the IGB Series main board PS 018 and the IGX Series main board PS 016 However basic operations are same for these models Manual No 085 3435 07 36 45 IGB GX Series Overseas Specifications Service Manual Chapter 4 Maintenance 4 1 Disassembly Procedure for Display Unit Disassembly procedure 1 If batteries are being used make sure to remove them or when using an AC adapter extract the cable from the power outlet IGB Series only When using AC power make sure to extract the cable from the power outlet IGX Series only 2 Remove the two angle adjusting knobs 3 Remove the Void Seal covering the sealing screw hole Void seal Remove the 8 screws including the sealing screw mentioned above that hold the front and rear cases together Manual No 085 3435 07 37 45 IGB GX Series Overseas Specificat
15. Overseas Specifications Service Manual 3 Hardware Configuration 3 1 Mechanical Parts IGB IGX Series IGB IGX Series Overseas Specifications Service Manual 27 45 Manual No 085 3435 07 Series Service Parts List Part Name CASE FRONT Remark 900 0756 05 CASE REAR BATTERY 900 0753 04 COVER BATTERY 900 0754 08 BRACKET 900 0725 00 BRACKET 900 0726 03 WASHER RUBBER 900 0748 05 FILTER DISPLAY 900 0755 01 SHEET Varied per country SHEET DISPLAY Varied per country SHEET COVER 900 0793 03 SPRING 1 900 1013 05 SPRING 2 900 1014 18 CUSHION BATTERY 900 0319 01 NAME PLATE SPEC Varied per country NAME PLATE SPEC Varied per country PWB PS 018 900 0677 04 PWB PS 019 CABLE LOCKING PG 11 900 0767 06 900 0758 02 HARNESS 52 GND 900 0772 05 SCREW M 4x45 SHEET 900 0842 02 900 1064 05 SIDE COVER 900 0037 11 POLE STAND RUBBER RING 900 0032 49 900 0207 07 PLATTER 072 8847 05 SHEET PLATTER 900 0100 02 PLATE SUPPORT 900 0021 11 BASE 900 0020 35 FOOT LEVEL 900 0022 05 PLATE 900 0222 03 LEVEL UNIT ASS 900 0315 15 BRACKET LEVEL 900 0010 01 LOAD CELL LOC ISS10 100kg 900 0815 01
16. V ISHIDA A IGB IGX Series Overseas Specifications Service Manual The First Edition IGB Series IGX Series FN eri B Read this manual thoroughly and do not perform installation operation maintenance or inspection unless you fully understand all of the contents B Keep this manual in a safe place where you can refer to it easily while installing operating and carrying out maintenance or inspections This manual is for use by service personnel of our company or qualified to perform maintenance services for this machine Use by anyone except the above personnel is not permitted Manual No 085 3435 07 ISHIDA CO LTD 86547 CONTENTS CHAPTER 1 PRODUCT OVERVIEW cient uoce reete 3 tI Machine Outlines steht E 3 1 2 Standard 3 1 3 ioe es ee es 5 Tur Display Unit 2 iii nO etf fiet 6 1 5 Outer DIMENSIONS i eet AFE 7 CHAPTER 2 TEST MODE onn err eere iii aii Te are reo reri Cose ee Eee pua eae 9 251 gt gt 9 2 1 1 Starting Each MOde 9 2 1 2 Endin
17. g Test Modes eene ae aes 9 2 752 10 2 1 4 FUrCLODS oen td 10 ARE Be ET 11 2 2 C1 Mode Country No Scale No Zero point Span 12 2 2 1 Country No Table RR 12 222 Scale HH deb E Pedes E rr shed ttt tas ted em eo atat 13 2 2 3 Operation Procedure sssssssssssssssssesseeeenenee nemen nnn daaa Enenda reni nnne 14 2 9 C2 Mode Key e rre tener ER D EXER ER SER ERR AY VER A Sue eR e RR FR oou RE ct 18 2 4 Mode Display Check 1 Simplified Check Ne 18 2 5 C4 Mode Display Check 2 Detailed Check 19 2 6 C5 Mode Program No Display csini eii EEEa 19 2 7 Mode RAM Clear and E2ROM 20 28 Mode Weighing Condition 21 2 9 C8 Mode E2ROM Data 24 2 10 C9 Mode Board Inspection A D Check I F 26 CHAPTER 3 HARDWARE CONFIGURATION ee 27 3 1 Mechanical Parts Nt 27 3 1 1 Doer Us 30 3 2 Electric Parts IGB
18. ing Condition Setting Setting Country No and Scale No determine the weighing conditions for securing certified specifications of the country Individual contents can be changed in this mode Specifications must be selected when used overseas Operation Display 1 Starting Test Mode Press ON OFF f I Press and hold ZERO while all segments lit 2 Entering C7 Mode Press ZERO six times 4 Or press TARE three times 3 Press SET To change data h Select the desired data by pressing ZERO to increase or TARE to decrease the address 3 digit address A Upper data Data To fix the data or advance the address Press f H i h h 3 digit address B Lower data Data 4 After changing data Push the Memory Switch SW1 located on the main am board ri This does not work when there was no data change 5 Press COLUMN twice to return to Test Mode Addresses for weighing condition settings from 110 to 115 Reference Reference Refer to the next page Manual No 085 3435 07 21 45 IGB GX Series Overseas Specifications Service Manual Weighing Condition Setting Table Address Manual No 085 3435 07 Decimal point position OJN Minimum graduation Accuracy Resolution A Changing method Weight unit lt 0 Valid
19. ions Service Manual 5 Open the front and rear cases IGB Series IGX Series Note Reverse the procedure to re assemble the display unit then affix a new Void Seal Part No 040 9585 01 Size 021 4 2 Replacement of Main Board 4 2 1 IGB Series 1 The procedure for opening the Front and Rear Cases is described in the previous section 2 Main Board PS 018 Extract the cable from the XJ2 connector Desolder the four lead wires of the Load Cell cable Manual No 085 3435 07 38 45 IGB GX Series Overseas Specifications Service Manual Remove the four screws holding the main board Reverse this procedure to install a new main board Note After installing a new main board carry out RAM Clear in C3 mode adjust the scale and set the user operation setup and program modes 4 2 2 Series 1 The procedure for opening the Front and Rear Cases is described the previous section 2 Main Board PS 016 Extract the cable from the XJ2 connector Desolder the four lead wires of the Load Cell cable Manual 085 3435 07 39 45 Series Overseas Specifications Service Manual Remove the screw holding the grounding cable to the rear case Remove the four screws holding the main board Reverse this procedure to install a new main board Note After installing a new main board carry out RAM Clear in C3 mode adjust the scale and set the user operation setup and program modes Ma
20. layed Tri Trimming display will appear This is possible even with the weight placed fra 2 Trimming Up Press ZERO then Tri U will be displayed Press ZERO for the desired number of times to increase the span 3 Trimming Down Press TARE then Tri d will be displayed Press TARE for the desired number of times to decrease the span Note The change amountfor one time may differ 12 depending on each machine however approximately one count for one time is average fra TE 4 Repeating Steps Press COLUMN then A D data will be displayed Place a weight on the weighing platter and perform adjustment by repeating steps 1 2 and 3 above 95954 5 Saving Data After completing the adjustment press COLUMN to save the data Manual No 085 3435 07 19 45 Series Overseas Specifications Service Manual Memory Switch The memory switch is located on the main board IGB Series Series Pushing memory switch Manual No 085 3435 07 17 45 IGB GX Series Overseas Specifications Service Manual 2 3 C2 Mode Key Check Operation Display 1 Starting Test Mode C1 Press ON OFF i Press and hold ZERO while all segments are lit L 2 Entering C2 Mode Press ZERO 3 Checking Keys Press SET h
21. nual No 085 3435 07 40 45 IGB GX Series Overseas Specifications Service Manual 4 3 Replacing and Adjusting Load Cell Load Cell Specifications Rated Rated Input Output insulation Capacity Output Resistance Resistance Resistance Model Type IGB X 60 LOC ISS10 100kg 100kg 2 0mV V x 5 15009 1092 10000 30 IGB X 150 LOC ISS10 300kg 300kg 2 0mV V x 5 15000 100 1000030 N 5 1 Using an allen wrench remove the four hexagon headed bolts and spacers fixing the load cell unit from the top of the base 2 Remove the four hexagon headed bolts and spacers from the bottom of the base Manual No 085 3435 07 41 45 IGB GX Series Overseas Specifications Service Manual 3 Remove the load cell unit Then install a new load cell unit and reverse the above procedure 4 3 1 Checking and Adjusting Gap of Four corner Limit In the two spots of the four corner limit front and of the four corner limit rear display pole side adjust the gaps to the following values Fate iGB amp iGX 60kg 1 1 9 2 1 IGB amp iGX 150 kg Hlz3 8mm H2 3 5mm Li H1 Manual No 085 3435 07 42 45 IGB GX Series Overseas Specifications Service Manual 4 3 2 Performing Zero Point and Span Adjustments Reference Refer to 2 2 C1 Mode of Chapter 2 Test Mode Manual 085 3435 07 43 45 Series Overseas Specifications Service Manual
22. on place a 30kg weight then 15000 Zero point 20000 35000 counts One graduation equals 5 counts M re J Processing is automatically executed in the following order Calib Calibration Computing process executing C OK Calibration OK Computing result succeeded No of adjusted counts Computing result 7 A C Err will be displayed indicating a computing result error when span adjustment is performed without placing a weight Place a weight and press TARE m n Calibration error 7 Saving Data To save Country No Scale No Zero point and Span data in E2ROM Remove the weight from the weighing platter Remove the seal covering the opening on the rear case of display unit Insert a thin rod such as the inner shaft of a ball point pen into the hole and push the Memory Switch located on the main board When writing has finished normally S OK will be displayed P na ay To release the above status press COLUMN Then the display will return to A D data AT Ca 8 Finishing Procedure OFF status Press ON OFF to finish this procedure Manual 085 3435 07 15 45 IGB GX Series Overseas Specifications Service Manual When Performing Fine Span Adjustment 1 Trimming After span adjustment press COLUMN while the A D data is disp
23. ram Memory Media e Mask ROM 256KB Writing or replacement is not possible e There is no compatibility between the IGB Series main board PS 018 and the IGX Series main board PS 016 However basic operations are same for these models 3 2 3 Power Board PS 019 PS 019 oN icN3 i i 5 i To main board Batteries Jack center Jack When the DC plug of the AC adapter is inserted into the DC jack the battery GND will be interrupted Manual 085 3435 07 33 45 IGB GX Series Overseas Specifications Service Manual 3 3 Electric Parts IGX Series 3 3 1 IGX Block Diagram Display Unit Main Board PS 016 Earth Board steel holder Eh AC Input Scale Unit Load Cell Manual No 085 3435 07 34 45 IGB GX Series Overseas Specifications Service Manual 3 3 2 Main Board PS 016 Parts Surface of Main Board The LCD and tact keys are installed on the soldering surface 1 2 3 CPU AD CONVERTER OP AMP uPD789407AGC AD7714YR 2 0 07 0 JP2 X YA25 NOL SOOO Eni ili cd axa Gains TRI VEX GND IN IN p CW 66 Bg SH3 TOP SILKSCREEN LAYER SW1 Memory Switch Used to write the data when performing initialization in Test Mode Used to save write the data in E2ROM after changing Country No and Scale No and performing Span Adjustment Connector XJ1 This connector is not used Pin No Signal Name o1
24. source For the IGX Series a VFD is adopted and a wide selection of power sources ranging from 100 VAC to 240 VAC is available 1 2 Standard Specifications Contents Model Name IGB Series IGX Series OIML R76 Class III Weighing Capacity Accuracy Non OIML ASIA Weighing Capacity Accuracy 1 6000 1 7500 1 6000 1 7500 Ib kg Switching Specification USA Weighing Capacity 150lb 60kg 3001 150 150lb 60kg 300lb 150kg 0 051b 0 02kg 0 11b 0 05kg 0 051b 0 02kg 0 11b 0 05kg Accuracy 1 3000 Weighing Platter 550mm L x 400mm W Display ABS resins Exterior Material Display pole Aluminum die cast Weighing platter Stainless SUS304 Display Angle Adjust Angle adjustable from the horizon 0 to the front Knob locking method Weight 16 0kg excluding batteries 16 8kg RCM c Temperature from 5 C to 40 C Relative humidity 8096RH max without condensation Manual No 085 3435 07 345 IGB IGX Series Overseas Specifications Service Manual wm 71 Model Name IGB Series Series IGB 60 IGB 150 IGX 60 IGX 150 Power Source Two dry batteries not included with the The required transformer is provided for machine or optional AC adapter each 100VAC 120VAC 220VAC or Battery Life 240VAC Conditions No option Temperature 20 C Relative humidity 6096 RH Two D size alkaline batteries Approx 500H continuous use Power Consumption 10
25. ss Press ZERO to increase an address Press to decrease an address Address 3 digits Data 1 byte Address 000 t key Address 110 C8 Starting address EROJ key Address 127 4 Press COLUMN to return to Test Mode E2ROM Data Address Item Data Range Remarks 0 to 99 Preset data 10 PLUs 0 to 60000 Data set in Program Upper limit 17bit Mode of Operation ue Lower limit 17bit 10 byte x 10 data Tare amount A range 18bit Tare amount B range Single weight 20bit B5 Reference e Check sum 8bit Refer to IGB IGX Operation Manual Scale mode data Capacity bit1 0 to F Ib mode bit2 Counting bit3 Manual No 085 3435 07 24 45 IGB GX Series Overseas Specifications Service Manual Address Item Data Range Remarks T 101 100A and 100B check data Writing twice 102A Selection of ON OFF key function bit 0 Data set in Setup Selection of Preset auto call up function bit 1 Mode of Operation Selection of 16 24 digit printer bit 2 Manual Selection of Date print function bit 3 102B Selection of Preset No print function bit4 Selection of single consecutive chit print bit5 Reterence Selection of Tare amount print function bit6 Refer to IGB IGX Selection of Upper Lower limits print function bit7 Operation Manual High level buzzer output setting bit 0 to 3 0 to F F15
26. stment The following weight can be selected kg 1 1 0 1 2 0 1 2 5 1 5 0 of weighing capacity Ib 1 1 0 1 2 0 1 2 5 1 5 0 of weighing capacity kg unit Same weight is used as weighing capacity Pressing ZERO selects the next item in the above sequence and pressing TARE selects the previous item Example Selecting kg unit and 1 2 0 for weighing capacity 150kg will require the total 75kg weight kg unit Half weight is used of weighing capacity To change between Ib and kg press ZERO and TARE at the same time Ib unit Same weight is used as weighing capacity 5 Zero Point Adjustment After selecting the weight amount ensure that nothing is placed on the weighing platter then press SET The previously set zero point A D data will be displayed T Zero point indicator lt will light up Press ZERO to set 20000 counts forcibly p LH Ca Zero point indicator will go off Manual No 085 3435 07 14 45 IGB GX Series Overseas Specifications Service Manual Operation Display 6 Span Adjustment Place the selected weight on the weighing platter then press Example 60kg Scale Weight selection kg unit and 1 1 Place a 60kg weight 30000 Zero point 20000 50000 counts In case of kg unit 1 2 for a weight selecti
27. t lights in sequence for each display digit Program No display Settings for weighing conditions Reading E2ROM data Board check A D check Interface check for factory inspection RAM clear Program mode data E2ROM clear Program mode data and Test mode 1 data Span adjustment is required Manual 085 3435 07 11 45 Series Overseas Specifications Service Manual 2 2 C1 Mode Country No Scale No Zero point Span adjustment 2 2 1 Country No Table Country Name EU AUS ASIA USA 2 Country Code 12 5 6 9 ADRS POS WGT Function Default Data Change not allowed Start width Stable Re stable count Stable Re stable width Re stable operation start width Zero point mark display Display loss than true IN Decimal point display veracale range 2 4 Tare clear with ZERO key Zero suppress Key in tare subtraction Zero tracking Micia weight follow up Unstable width PAU displa Stable display WB only Reserved Reserved Reference Reference 1 By setting the country code weighing conditions will function based on the default data from address 112 to 115 2 The data is set to meet certified conditions for each country so there is no need to change the data 3 Position A indicates the upper position of one byte data and B indicates the lower position
28. tion that if not heeded is likely to result in loss of life or serious injury Indicates information that if not heeded may result in loss of life or serious injury Indicates information that if not heeded could result in relatively serious injury damage to the machine or faulty operation neterence Indicates a page to refer to EG Q Information Indicates information to help you understand the related text e Readers of this manual This manual is designated for use by servicing personnel Use by other personnel is not permitted e This manual may be revised in accordance with modifications to the machine All rights are reserved Copying any part of this manual is prohibited without the permission of Ishida Manual No 085 3435 07 2 45 IGB IGX Series Overseas Specifications Service Manual Chapter 1 Product Overview 1 4 Machine Outline e The base of software used is the same as that of the IGB and IGX Series Therefore the Setup and Test mode items are same as those of the IGB and IGX Series The machine functions are available within these standard specifications A check function of the upper and lower weight limits are standardly provided with the IGB and IGX Series e The main board is different from that of the IGB and IGX Series However basic operations are same for these models e For the IGB Series an LCD is adopted and either two dry batteries or an AC adapter be used as a power
29. ty 1 6 116 696 of weighing capacity 1 5 420 of weighing capacity 31 4 425 of weighing capacity x 1 3 433 3 of weighing capacity 1 2 450 of weighing capacity 9 and more Invalid 112B EM Stable Re stable count 0 through 15 times 113A EU Stable Re stable width n 0 through 15 xn 10 e 113B Re stable operation start 0 through 15 n 10 width a essay ar oe zh 1 Minus numeric value H Zero supress display Multi Interval NOR WN specification only Key in preset tare subtraction and preset single weight function Preset unit weight function aC Unstable width 0 0 5e 1 20e 115B No of PLUs and PLU 0 10 PLUs 1 5 PLUs display IGB only Display No display Stable display 0 display 1 Y cursor display IGB only 4 Weight unit cursor display 0 Always light 1 Light only when No change is set a Manual 085 3435 07 23 45 IGB GX Series Overseas Specifications Service Manual 2 9 C8 Mode E2ROM Data Reading Data from address 000 to address 127 can be read Operation Display 1 Starting Test Mode 1 Press ON OFF f Press and hold ZERO while all segments are lit 2 Entering C8 Mode Press ZERO seven times H Or press twice 3 Press SET To change an addre
30. unstable first replace the Load cell is defective main board then replace the load cell If outside of the start range perform Zero and Span adjustments When performing Zero and Span adjustments if the weight that is less than the weighing capacity reaches the lower limit replace the load cell e 2 Main board is defective Replace the main board PS 016 IGX or PS 018 IGB with a normal one then check Manual No 085 3435 07 44 45 IGB GX Series Overseas Specifications Service Manual Symptoms Causes Remedies Zero point or weight is unstable 1 Vibration due to wind or e f Weighing platter is subject to conditions at place of wind move the scale to the place installation where there is no wind or provide something to block the wind If there is any vibration at the place of installation move the scale to the place where there is no vibration 2 Interference to Weighing Perform visual inspection to check platter Platter support or whether something is touching the Load cell Weighing platter Platter support or Load cell and remove if any 3 Main board or Load cell is e Perform Test mode C1 and check defective A D value and replace A D board and Load cell in this order if necessary 4 Extraordinary e Determine the source and remove electromagnetic wave it or move the scale to a place where the scale will not be subject to the electromagnetic waves No response or input difficult
31. y in 1 Defective key e Replace the tact key soldered to the key operation Main board 2 Bad clearance between e Install Main board along Keysheet Keysheet and Keys Main face board 3 Defective Main board e Replace Main board Non displaying part double 1 Defective Main board Replace Main board display digit or double segment Manual 085 3435 07 45 45 Series Overseas Specifications Service Manual l DA Design and specifications are subject change without notice A ISHIDA CO LTD 44 SANNO CHO SHOGOIN SAKYO KU KYOTO 606 8392 JAPAN PHONE 81 75 771 4141 FACSIMILE 81 75 751 1634 ULR http www ishida co jp