Home
CA Manual (portugese) 77155
Contents
1. quente Interruptor de Ganho Esse interruptor permite ao amplifi cador ser configurado de acordo com o padr o de sensibili dade de entrada 775V para pot ncia fixada em 80 ou para ganho opcional de voltagem X40 ou X20 Refere se s especifica es para valores de sensibilidade de entrada no ganho opcional de voltagem de X40 e X20 NOTA na vers o 5 way Output Binding Post do CA18 s o fornecidos dois pares de 5 way binding posts para cada canal de modo a possibilitar a conexdo dos falantes em para lelo SEMPRE desligue o amplificador antes de mudar as especificac es tanto com o interruptor XLR Pino ou com o interruptor de Ganho a Interruptor Pino XLR Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 Interruptor de Ganho Ap ndice E CREST AUDIO Crest Audio Inc 100 Eisenhower Dr Paramus NJ 07652 USA TEL 201 909 8700 FAX 201 909 8744 http www crestaudio com Printed in USA A escolha dos profissionais v 1 0 10 13 97 O 1997 Crest Audio Inc C4400013
2. o de Conex o de Sa da Conex o de Sa da 5 Way Binding Post Canal A Et reo Paralelo Conex o de Sa da 5 Way Binding Post Mono em Ponte Conex o de Sa da 5 Way Binding Post Canal B Et reo Paralelo Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO The CA18 rear panel features external switches for the fol lowing XLR Pin Switch This switch configures XLR input con nection polarity Either pin 2 or pin 3 may be selected as the hot pin Amplifiers are shipped pin 2 hot from the factory Gain Switch This switch permits the amplifier to be config ured for the standard input sensitivity 775V for rated power O 89 or for optional voltage gains of X40 or X20 Refer to the specifications for input sensitivity values at optional volt age gains of X40 and X20 NOTE on the 5 way Output Binding Post version of the CA18 two pairs of 5 way binding posts are provided for each channel so that paralleling of speakers is possible A CA18 Versao Binding Post Vis o Traseira Ap ndice E CA18 Funcoes Especiais O Painel traseiro do CA18 tem os seguintes interruptores externos como caracter sticas Interruptor Pino XRL Esse interruptor configura a polari dade da conex o de entrada XRL Tanto o pino 2 quanto o pino 3 podem ser selecionados como o pino quente Os amplificadores s o configurados de f brica com o pino 2
3. painel A imped ncia de carga nominal m nima no Modo Mono em ponte de 4 ohms o que equivale a usar os dois canais separadamente a 2 ohms Usar em ponte uma carga abaixo da m nima recomendada ativar o circuito IGM resultando em perda de pot ncia e tamb m poder levar a uma condi o de prote o t rmica Veja as figuras nas p gina 12 que demonstram as infor ma es sobre conex es de sa da Prote o TourClass Todos os modelos da S rie CA possuem caracter sticas da Prote o TourClass Oriunda da larga experi ncia da Crest com as maiores empresas de aluguel de som do mundo O grupo de circuitos TourClass estabelece novos padr es na prote o dos circuitos internos e de todas as cargas conectadas ACL Limitador Ativo de Clip Na pot ncia m xima do amplificador ou ponto de clip o ACL ser ativado Isso indicado pela ilumina o do LED de Clip O ganho do canal ser automaticamente reduzido prote gendo os alto falantes de um dano provocado por alta pot n cia e componentes DC O ACL pode ser ativado por realimen ta o descontrolada oscila es um ajuste impr prio do ganho ou o mau funcionamento de um equipamento que este ja conectado ao amplificador Somente um clipping est vel ou muito intenso acionar o ACL nenhum transit rio normal do programa Quando em opera o o circuito virtualmente transparente Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA
4. sinal terra ao chassis terra AC A posig o mais alta da chave suspende o sinal terra do amplificador Em um sistema apro priadamente projetado para proporcionar seguran a e mini mizar ru dos o amplificador deve ser conectado ao terra atrav s do cabo de alimenta o AC Sempre que poss vel o equipamento fonte de sinal deve compartilhar do mesmo terra AC assim como o amplificador Em alguns casos isso pode nao ser poss vel e resulta em um loop de terra Se isso aconte cer O primeiro passo deslocar a chave para a posi o superi or posi o lift Nessa posi o o sinal terra suspenso e os circuitos do amplificador ficam completamente isolados do chassis terra AC Persistindo o problema do loop de terra mesmo depois que a chave tiver sido colocada na posi o lift as blindagens das linhas balancedadas dos sinais de entrada devem ser aterradas em apenas uma das extremidades geralmente no lado da fonte de sinal 13 14 Conectores de Entrada Balanceados tipo 1 4 TRS e XLR Esses conectores aceitam sinais de entrada com linhas balanceadas atrav s de plugs tipo 1 4 TRS e XLR Veja a figura direita para maiores informa es sobre polaridade dos conectores Os conectores para cada canal est o em paralelo e os conectores em desuso devem ser usados para a conex o com outros amplificadores Nota Plugs n o balanceados 1 4 Mono devem ser usados com os conectores TRS Tip Ring Sleeve O te
5. Appendix E Input Sensitivity The CA Series amplifiers have a standard input sensitivity of 775 Volts for rated power at 8 Ohms Models CA2 CA4 CA6 CA9 and CA12 are fitted with an internal jumper which allows optional gains of X20 or X40 Model CA18 features an external voltage gain input sensitivity switch See Appendix E Standard and optional voltage gains input sensitivities are detailed below NOTE This jumper is NOT user configurable Please consult your supplier or local Crest Audio service center if you wish to have the voltage gain input sensitivity changed CA SERIES Configura o Interna e Controle Polaridade da Entrada XLR Os amplificadores da S rie CA s o padronizados com o XLR configurado como Pino 2 quente Uma liga o interna possibilita alterar o amplificador para pino 3 quente NOTA Essa mudan a n o pode ser feita pelo usu rio Por favor consulte o fornecedor ou a assist ncia t cnica local da Crest Audio se voc deseja mudar a polaridade de entrada XLR O modelo possui um seletor externo de polaridade do conec tor XLR Veja ap ndice E Sensibilidade da Entrada Os amplificadores da S rie CA t m uma sensibilidade padr o de 0 775 volts para pot ncia m xima em 8 ohms Cada ampli ficador ajustado com uma ponte interna que permite um acr scimo opcional de X20 ou X40 A sensibilidade de entra da padr o ou de ganho opcional de voltagem est o detalhados a
6. CHANNEL A PREAMP 2 3 R 7 a NON INVERTED 2 ATTENUATOR OUTPUTSTAGE 1 INVERTED PIN2 3 JUMPER REAR PANEL SWITCH 1 ON CA18 BRIDGED PARALLEL STEREO SWITCH Er AMP FRONT END OUTPUT RELAY t PREAMP INCORPORATES INPUT SENSITIVITY VOLTAGE GAIN JUMPER REAR PANEL SWITCH ON CA18 ATTENUATOR OUTPUTSTAGE 5 NON INVERTED 4 B INVERTED PIN2 3 JUMPER REAR PANEL SWITCH ON CA18 Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 PREAMP P CHANNEL B AMP FRONT END OUTPUT RELAY Ap ndice B Comprimento do Cabo sem dobras metros 2 10 30 Ap ndice C Ap ndice C Tabela de Dimensao dos Cabos M trico Dimens o do Cabo mm 0 3 0 5 0 75 1 5 2 5 4 0 5 0 75 1 5 2 5 0 5 0 75 1 5 2 5 0 75 1 5 2 5 10 Perda de Pot ncia carga de 8 ohm 2 9 1 74 1 16 0 58 0 35 0 22 4 3 2 9 1 45 0 87 0 55 0 37 8 24 5 6 2 9 1 09 0 73 15 5 8 2 5 1 3 2 2 2 Perda de Pot ncia carga de 4 ohm 5 6 3 4 2 3 1 16 0 70 0 44 8 2 5 6 2 9 1 09 0 73 15 5 10 8 5 6 2 9 1 09 0 73 15 5 9 8 6 3 4 3 2 6 CREST AUDIO Perda de Pot ncia carga de 2 ohm 10 8 6 7 4 5 2 3 1 39 0 87 15 5 10 8 5 6 3 4 2 2 1 45 28 19 9 10 8 6 7 4 3 2 9 45 28 12 0 8 2 5 1 A
7. Voc est entre o crescente n mero de profissionais de audio que tem feito da Crest Audio uma das l deres mundiais no fornecimento de sistemas de audio comercial industrial Para sua seguran a por favor leia a se o Precau es Importantes antes de instalar e operar o amplificador A S rie CA da Crest Audio baseada na mesma avan ada topologia de circuito que tem feito dos amplificadores da Crest Audio a escolha dos profissionais por todo o mundo A S rie CA foi projetada para uma alta efici ncia de funciona mento e um desempenho sonoro preciso em toda a faixa de udio mesmo sobre condi es severas Com o objetivo de manter o alto padr o de qualidade no desempenho todos os amplificadores da S rie CA s o produzidos com crit rios ri gorosos de fabrica o com o estado da arte da Crest ame ricana Os componentes internos s o os melhores dispon veis e os pontos chave de cada etapa de sub montagem s o testa dos passo a passo antes da montagem final Finalmente cada amplificador severamente testado usando equipamentos de precis o antes do embarque Ademais todos os amplifi cadores da S rie CA incorporam as exclusivas caracter sticas de prote o TourClass da Crest para guardar tanto os circuitos internos quanto os alto falantes conectados Essa combina o j provada de desenho avan ado constru o de qualidade e amplo circuito de prote o sua garantia con tra falhas e perda de seguran
8. estabelecida A m xima corrente s limitada pelo disjuntor do painel frontal Consulte as especifica es na se o de Ap ndices para calcular a corrente que cada amplificador requer Pag 9 SERIES Make sure the mains voltage is correct and is the same as that printed on the rear of the amplifier Damage caused by con necting the amplifier to improper AC voltage is not covered by any warranty Unless otherwise specified when ordered Crest amplifiers shipped to customers are configured as fol lows North America 120VAC 60Hz Europe 230VAC 50Hz Asia 220VAC 50Hz Australasia 240VAC 50Hz South America 120VAC 60Hz or 220VAC 50Hz Japan 100VAC 50Hz NOTE Always turn off and disconnect the amplifier from mains voltage before making audio connections Also as an extra precaution have the attenuators turned down during power up Cooling System and Requirements CA Series amplifiers use a twin tunnel forced air cooling sys tem to maintain a low even operating temperature Drawn in by dual 45 cubic feet per minute CFM fans on the rear panel air flows through the cooling fins of the channel heat sinks dissipating power transistor heat then exhausts through the front panel slots The intelligent variable speed DC fans are controlled by heat sink temperature sensing cir cuits When the amplifier is turned on the fans briefly rev up then slow to an idle this indicates that the tempe
9. is not excessive for your speaker system To ensure that the speakers never receive excessive power and to pre vent amplifier clipping use a properly adjusted external lim iter or a compressor with a ratio of 10 1 or higher to control power output Use one compressor limiter for each frequency band in systems with active electronic crossovers The ACL clip limiting circuit will automatically limit the duration of squared off continuous waveforms applied to the speakers The amplifier will however allow normal musical transient bursts to pass Of course when the amplifier does clip it is operating at its maximum output power Note that some speaker systems are packaged with proprietary proces sors that have power limiting circuits and therefore should not require additional limiting Do not drive any low frequency speaker enclosure with fre quencies lower than its own tuned frequency the reduced acoustical damping could cause a ported speaker to bottom out even at moderate power Consult the speaker system specifications to determine its frequency limits and employ a roll off filter if necessary Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 SERIES Frequ ncia Subs nica Fabricados com um sistema de filtros passa alta os amplifi cadores de S rie CA s o protegidos contra frequ ncias sub s nicas em cada canal Ademais o rel abrir se aparecer energia provenie
10. pre tested before final assembly Finally each amplifier is burned in and thoroughly tested using precision audio test equipment before shipping In addition all CA Series amplifiers incorpo rate Crest s exclusive TourClass protection features to safe guard both internal circuitry and connected loudspeakers This proven combination of advanced design quality con struction and comprehensive circuit protection is your guar antee of fail safe reliability You can depend on consistent stable performance even when your CA Series amplifier is subjected to punishing extremes in the most demanding fixed or mobile sound reinforcement applications Unpacking Please inspect the amplifier carefully immediately after unpacking If you find any damage notify your supplier deal er immediately Only the shipper may file a damage claim with the carrier for damage incurred during shipping Be sure to save the carton and all packing materials for the carrier s inspection If your packing materials are in good condition please save them If you ever need to ship the unit back to Crest Audio or an authorized service center you should use only the original factory packing Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 SERIES Introdu o Parab ns Por sua compra de um novo amplificador de pot ncia da S rie CA e gostar amos de agradecer a sua confi an a nos produtos Crest Audio
11. ser mantidos limpos para assegurar a ventila o adequada do equipamento Se o amplificador for usado em ambiente empoeirado ou com muita fuma a o filtro deve ser limpo ou substitu do frequentemente e o equipamen to dever periodicamente receber um jato de ar comprimido para livrar se de qualquer part cula estranha que possa ter penetrado atrav s do filtro Os usu rios n o precisar o fazer nenhum ajuste no amplifi cador durante toda sua via til N o existe nenhum ajuste que possa ser feito pelo usu rio que exija a abertura do amplifi cador A remo o da tampa ir exp lo ao risco de choque logo todo servi o dever ser feito pelo pessoal qualificado da assist ncia t cnica autorizada da Crest Audio Responsabilidade do Usu rio Seu amplificador da S rie CA muito potente e pode ser potencialmente perigoso tanto para os alto falantes como para os operadores de sua responsabilidade ler a se o Precau es Importantes e assegurar se que o amplificador seja apropriadamente instalado conectado e operado de maneira correta como est instru do nesse manual Muitos alto falantes podem ser facilmente danificados ou destru dos por sobrecarga especialmente com a alta pot ncia produzida por um amplificador em ponte Leia a se o Prote o do Alto falante e sempre esteja atento s capacidades de corrente con t nua e pot ncia de pico A Crest Audio n o respons vel por danos causados a alto falantes
12. 4 CA6 CA9 CA12 CA18 Pag 13 SERIES IGM Impedance Sensing IGM Instantaneous Gain Modulation is an innovative circuit that allows the amplifier to operate safely into loads as low as 2 ohms When the amplifier sees a load that overstresses the output stage the IGM circuit adjusts the channel gain to a safe level Like ACL the IGM circuit is inaudible in normal use In addition if extreme and sustained low impedance is encountered the amplifier s output relay will open AutoRamp Protection Auto Ramp operates every time the amplifier is turned on or is reactivated after a protect condition is corrected This exclusive Crest Audio feature gradually increases gain to the attenuator setting avoiding unnecessary stress on the loud speakers Thermal Protection Abnormally high heat sink temperatures will engage the Protect circuit for the overheating channel only An output relay disconnects the loudspeakers until nominal temperature range is restored During this time the Protect LED will light If the power transformer gets too hot its thermal sens ing circuit will disconnect both channel outputs During this time the Active LED will extinguish the Protect and Clip LEDs will stay lit and the cooling fan will continue running at low speed Normal operation resumes once the transformer cools to a safe level Short Circuit If an output is shorted i e defective speakers or crossed speaker wires the IGM and
13. ES CREST AUDIO _ AMPLIFICADORES DE POTENCIA PROFISSIONAL SERIES D e CREST 8 AUDIO O E gt o a JE 2 E O sa Ea proto Poe Als SSeS O gt gt no gt CREST 22 AUDIO Sa A MW O achis 3 OCN E DA x ED e NS E q PS ab O Ae O AS o Oo 8s SS ay E CREST 8 AUDIO 3 estos O op O AY O sw O e ANE O ra O W gt o o O Active SS aa o Ay eee Rih y j SS CREST AUDIO a y OS E 3 asiu O dd O ties 1 3 2233 a i rom o SANS O ae gt A O gs On CREST 8 AUDIO ca gt om O aut E 3 O sm O AY 3 o rae o AN E ED O Active oo of E ED i ome E o a che lt A al o MANUAL DO PROPRIET RIO Precaucdes Importantes 1 Esse S mbolo usado para alertar o operador A seguir importantes pro cedimentos operacionais e precau es detalhadas na documenta o Esse s mbolo usado para advertir o operador que voltagens potencial mente perigosas est o presentes na parte inter na do equipamento e que podem representar
14. a dos da seguinte maneira Am rica do Norte 120VAC 60Hz Europa 230VAC 50Hz sia 220VAC 50Hz Austr lia 240VAC 50Hz Am rica do Sul 120VAC 60Hz ou 220V AC 50Hz Jap o 100VAC 50Hz Nota Sempre desligue e desconecte o amplificador da ali mentac o AC antes de fazer as conex es de udio Tamb m como precaucdo extra ajuste os controles de volume para o m nimo quando for lig lo Sistema de Resfriamento e suas Exig ncias Os amplificadores da S rie CA usam um sistema de duplo t nel de resfriamento para manter a temperatura interna baixa Dois ventiladores com vaz o de 45 p s c bicos por minuto CFM projetam o ar para o interior do amplificador fazen do o circular por entre as aletas dos dissipadores de calor dos transistores de pot ncia saindo pelas fendas do painel frontal Os ventiladores inteligentes de velocidade vari vel DC s o controlados por um circuito sensor montado no dissipador de calor Quando o amplificador ligado o ventilador funciona a uma alta velocidade e ap s alguns segundos a velocidade reduzida mantendo se lenta indicando que os circuitos sen sores de temperatura est o funcionando normalmente A velocidade do ventilador s aumenta se for necess rio devido a um incremento de temperatura mantendo seu ru do no m ni mo Em uma situa o de sobrecarga extrema o ventilador for ar a entrada de um volume de ar maior atrav s dos dissi padores Se qualquer u
15. a Voc pode confiar no desem penho consistente e est vel mesmo quando seu amplificador da S rie CA for submetido s aplica es mais duras de sonoriza o tanto fixas quanto m veis Desempacotamento Por favor inspecione o amplificador cuidadosamente ime diatamente ap s desempacot lo Se voc encontrar qualquer dano notifique imediatamente seu fornecedor representante Somente o consignat rio pode fazer uma reclama o com a transportadora por danos ocorridos durante o embarque Assegure se de guardar a caixa e todo o material de empaco tamento para inspe o da transportadora Se o material de empacotamento estiver em boas condi es por favor conserve o Se alguma vez voc precisar enviar o equipamento de volta para a Crest Audio ou Assist ncia T cnica autorizada voc deve enviar somente na embalagem original de f brica Pag 5 C A Nunca tente segurar o interruptor disjuntor na posi o ON se o REST mesmo n o permanecer armado por si pr prio Sempre desligue o A amplificador ao alterar modos de operac o UDIO SERIES Installation and Mounting Four CA Series amplifiers are 2 rack space units models CA2 CA4 CA6 and CA9 Models CA12 and CA18 are 3 rack spaces high All mount in standard 19 inch racks Four front panel mounting holes are provided on each amplifier Rear mounting ears give additional support and use of rear supports is highly recommended in all mobile and touring s
16. aker s continuous and peak power capabilities Crest Audio is not responsible for damage to loudspeakers for any reason Pag 16 CREST AUDIO N o utilize caixa ac stica de graves com freqii ncias que este jam abaixo da freqii ncia de sintonia pr pria projetada para a mesma O reduzido amortecimento ac stico poderia causar dano ao cone de um alto falante montado numa caixa tipo bass relex bottom out mesmo com pot ncia moderada Consulte as especifica es do seu sistema de caixas ac sticas para determinar seus limites de freqii ncia e empregue um fil tro roll off se necess rio Cabos Recomendados para Caixas Ac sticas A tabela de dimens o dos cabos ir ajud lo a determinar a dimens o ideal do cabo de cobre para as suas caixas ac sticas Lembre se de que a resist ncia dos cabos do alto falante rouba a pot ncia do amplificador de duas maneiras atrav s da perda de pot ncia resistiva ou ohmica geralmente referida como perda de PR e atrav s do aumento da carga resistiva total a qual diminui a pot ncia dispon vel do amplificador As tabelas do Ap ndice C apresentam os comprimentos dos cabos em p s AWG e em valores m tricos Manutenc o Os amplificadores da S rie CA n o requerem nenhuma outra manuten o de rotina a n o ser uma limpeza ocasional e recoloca o dos filtros internos dos ventiladores na parte pos terior do amplificador Essa opera o n o requer ferramen tas Os filtros devem
17. baixo NOTA Essa mudan a na configura o n o pode ser feita pelo usu rio Por favor consulte seu fornecedor ou assist n cia t cnica local da Crest Audio se voc deseja ter a sensibi lidade de entrada ganho de voltagem alterada CA2 CA4 CA6 CA9 CA12 CA18 Gain Sens Gain Sens Gain Sens Gain Sens Gain Sens Gain Sens Std X45 715V X61 775V X68 775V X86 5 775V X97 5 175V X115 775V Opt 1 X40 866V X40 1 12V X40 1 32V X40 1 66V X40 1 87V X40 2 24V Opt 2 X20 1 73V X20 2 24V X20 2 65V X20 3 32V X20 3 74V X20 4 47V Operation Funcionamento Connecting Power Circuit Size Requirements CA Series amplifier power requirements are rated at a idle b 1 8th power typical music conditions c 1 3rd power continuous music conditions d maximum rated power circuit breaker limited The maximum power current draw rating is limited only by the front panel circuit breaker Consult the specifications in the Appendices section for figures on the current that each amplifier will demand Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 Tens o de Alimenta o Dimens es Requeridas do Circuito A pot ncia requerida para os amplificadores da S rie CA estabelecida em a repouso sem sinal de entrada b 1 8 de pot ncia condi es t picas de m sica c 1 3 de pot ncia condi es de m sica cont nua d Pot ncia m xima
18. balanced input lines should be grounded at one end only usually the signal source 13 14 Balanced 1 4 TRS amp XLR Input Connectors These connectors accept input signals on bal anced TRS and XLR input plugs See the fig ure at the left for information on polarity Connectors for each channel are in parallel the unused connectors may be used for loop through connection to other amplifiers NOTE Unbalanced Tip Sleeve plugs may be used with the balanced TRS Tip Ring Sleeve connectors The ring terminal or negative input will be connected to ground internally When using three pole stereo TRS connec tors make sure that the ring connection is made either to the cold output of the source equipment or to ground Incorrect connections may cause a 6dB loss in level 15 Fan Inlet Ports amp Filters Cooling air enters the amplifier through the fan inlet ports located on the rear of the amplifier chassis Be sure not to block these ports when installing the amplifier or other associated equipment Air must flow unimpeded through these ports Fan filters removable without tools are provided to minimize entry of dust and dirt Pag 8 Tip Positive Ring Negative Sleeve Ground CREST AUDIO 12 Interruptor de Suspens o do Terra O interruptor de suspens o do sinal terra ajustado na f bri ca na posi o ground terra que conecta eletricamente o
19. cadores ou consoles a qualquer fonte de tens o independentemente do amplificador ou console estar ligado ou desligado N o conecte a sa da de qualquer canal do amplifi cador com a entrada de qualquer outro canal N o conecte a sa da de um amplificador com a sa da de qualquer outro em s rie ou em paralelo A Crest Audio e seus dis tribuidores n o se respon sabilizam por dano aos alto falantes por qualquer raz o N o aterre nenhum termi nal quente Nunca conecte uma sa da quente ao terra ou a outra sa da quente Per odos de n o utiliza o o equipamento dever ser desligado da tens o de aimenta o quando n o for utilizado por um longo 21 22 per odo Informa es sobre Assist ncia O equipa mento deve ser assistido pelo pessoal qualificado quando Quando o cabo de alimen tac o ou tomada tenham sido danificados Tivier ca do objetos ou der ramados l quidos no interi or do equipamento O equipamento tiver sido exposto a chuva O equipamento parecer n o funcionar ou apresen tar uma mudanca significa tiva em seu desempenho O equipamento tenha ca do ou tenha seu gabi nete danificado Para obter assist ncia contate o Centro de Assist ncia da Crest Audio mais pr ximo o Distribudor O Representante ou a Crest Audio pelo numero 201 909 8700 EUA No Brasil ligue para 071 358 8313 CREST AUDIO Table of Contents Man
20. calor alcan ar um n vel anormalmente alto o circuito de prote o ser acionado ape nas para o canal superaquecido Um rel de saida desconecta o alto falante at que a temperatura nominal normal seja restaurada Enquanto isso o LED de Prote o acender Se o transformador da fonte de alimenta o esquentar demais seu circuito sensor t rmico desconectar os dois canais de sa da Durante esse per odo o LED Ativo apagar os LEDs de Prote o e Clip continuar o acesos e o ventilador de resfria mento continuar a funcionar em velocidade normal O fun cionamento volta ao normal assim que o transformador tiver resfriado a uma temperatura segura Curto Circuito Se uma sa da entrar em curto por exemplo um alto falante defeituoso ou um cruzamento dos condutores do cabo do alto falante o IGM e os circuitos t rmicos automaticamente prote ger o o amplificador O circuito IGM identifica o curto cir cuito como uma situa o de carga extremamente baixa e ate nua o sinal protegendo os transistores de sa da do canal de uma sobrecorrente Se o curto circuito permanecer a carga ser desconectada pelo circuito de prote o t rmica o rel da sa da se abre Prote o Contra Voltagem DC Se um canal de amplificador detecta a exist ncia de uma ten s o cont nua em seus terminais de sa da o rel de sa da abre os contatos imediatamente para evitar danos aos alto falantes O LED de prote o se acender A
21. e pelo telefone 201 909 8700 EUA Fax 201 909 8744 EUA No Brasil ligue para 011 6971 1641 Por sua complexidade de design e risco de choque el trico todos os reparos devem ser feitos somente pelo pessoal qualificado Se o equipamento necessi tar ser enviado de volta para a f brica deve ser enviado na caixa original Se for empacotado inadequadamente seu amplificador poder ser danificado Assistencia T cnica Pride Music www cesetec com br Crest Audio pelo endere o http www crestaudio com Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 Pag 17 SERIES Ap ndice A Especifica es Devo CE CREST AUDIO 2 4 6 9 12 18 1kHz 0 01 THD N 8Q Stereo Power 160W 250W 400W 600W 700W 1000W 03 THD N 40 Stereo Power 250W 435W 600W 900W 1200W 1800W 03 THD N 20 Stereo Power N A 500W 750W 1000W 1400W 2500W 03 THD N 8Q Bridged Mono Power 500W 830W 1200W 1800W 2400W 3600W 03 THD N 40 Bridged Mono Power N A 1000W 1500W 2000W 2800W 5000W 03 THD N 20Hz 20kHz 0 1 THD N 8Q Stereo Power 150W 245W 350W 550W 650W 950W 4Q Stereo Power 200W 400W 500W 800W 1100W 1700W 2Q Stereo Power N A 450W 600W 900W 1100W 2400W 8Q Bridged Mono Power 450W 800W 1000W 1600W 2200W 3400W 40 Bridged Mono Power N A 900W 1200W 1800W 2200W 4800W Max RMS Output Voltage each channel 44V 58V 73V 82V 90V 99V Max Peak Output Voltage 62V 82V 103V 116V 126V 140V Frequency Respon
22. e wire banana plugs or spade lug terminations Make con nections to both the Channel A and Channel B terminals for Stereo or Parallel Mode or a single connection across the red hot terminals only of Channels A and B for Bridged Mono Mode See Appendix D and the section on Mode Selection for more information NOTE on the 5 way Output Binding Post version of the CAIS two pairs of 5 way binding posts are provided for each channel so that paralleling of speakers is possible 11 Mode Selection Switch This recessed three position switch configures the amplifier for Stereo Parallel or Bridged Mono Mode operation Amplifiers are factory configured for Stereo Mode See Appendix D and the section on Mode Selection for more information Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 Painel Traseiro 10 Conectores de Sa da Seu amplificador possui conectores tipo borne 5 way biding post A conex o com o terminal de caixa pode ser feita com fio descoberto plug banana e terminal tipo crimp tipo garfo Fa a conex es com os dois terminais Canal A e Canal B para Modo Est reo ou Paralelo ou uma nica conex o atrav s dos terminais vermelhos quentes somente do Canal A e Canal B para Modo Mono em Ponte Veja o Ap ndice D e a se o Sele o de Modo para maiores informa es Nota Na vers o do CAIS que possui os terminais de sa da do tipo 5 Way Binding Post dois pare
23. ect o o O Ges o gt y CA9 Sag o 1 375 18 457mm gt A Ga o o o i ES a CAIZ 133mm CA 8 E T C y fetal o Nota Veja o Ap ndice E para detalhes do painel traseiro do CA 18 Pag 4 Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Introduction Congratulations on your purchase of a new CA Series profes sional power amplifier and thank you for your confidence in Crest Audio products You are among the growing number of audio professionals who have made Crest Audio one of the world s leading suppliers of professional and commercial industrial audio systems For your safety please read the Important Precautions section before installing and operating the amplifier The Crest Audio CA Series is based on the same advanced circuit topologies that have made Crest amplifiers the choice of touring professionals worldwide CA Series amplifiers are designed for high operating efficiency and accurate sonic per formance across the full audio bandwidth even under stress ful conditions In order to maintain strict quality assurance standards all CA Series amplifiers are built in Crest s state of the art USA manufacturing facility Internal components are the finest available and key sub assemblies are
24. enhuma garantia Mantenha os controles dos amplificadores na posi o de volume m nimo enquanto estiver ligando o equipamento para pre venir dano ao sonofletor caso existam n veis altos de sinais nas entradas Desligue e desconecte o equipamento da tens o de alimenta o antes de fazer as conex es Nunca segure o interruptor na posi o ON caso ele n o permane a l sozinho N o use o equipamento perto de fornos radi adores ou outros apare lhos produtores de calor N o bloqueie a entrada ou sa da do ventilador N o opere o e quipamento em uma superf cie ou ambi ente que possa impedir o fluxo normal do ar ao redor do equipamento tais como cama tapete carpete ou rack completamente fecha do Se o equipamento for usado em ambiente com muita poeira ou fuma a O 20 equipamento deve peri odicamente ser blown free soprado para tirar particulas estranhas Nao remova a tampa Remover a tampa ir exp lo a voltagens potencial mente perigosas N o existem partes internas teis so usuario Conectar a sa da do ampli ficador a oscilosc pios ou outro equipamento de teste enquanto o amplifi cador estiver no modo em ponte pode danificar tanto o amplificador quanto o equipamento de teste N o force as entradas com um nivel de sinal maior que o necess rio para produzir a pot ncia m xima do equipamento N o conecte as entradas sa das dos ampli fi
25. g 3 5 x 19 x 18 89 x 483 x 457mm 46 Ibs 20 88 kg Net Weight Warranty 33 Ibs 14 98 kg 3 years 41 lbs 18 61 kg 3 years 3 5 x 19 x 18 89 x 483 x 457mm 49 lbs 22 24 kg 44 lbs 19 97 kg 3 years 3 5 x 19 x 18 89 x 483 x 457mm 52lbs 23 60 kg 5 25 x 19 x 18 133 x 483 x 457mm 72 1bs 32 68 kg 5 25 x 19 x 18 133 x 483 x 457mm 82 Ibs 37 23 kg 47 Ibs 21 33 kg 3 years 67 Ibs 30 42 kg 3 years 77 Ibs 34 96 kg 3 years For full power at 4 Ohms See table below for optional settings Crest Audio reserves the right to make changes or improvements in manufacturing or design which may affect specification 1997 Crest Audio Inc 10 13 97 Garantia de 3 anos no Brasil Os Amplificadores da linha CA v m com garantia padr o de dois anos mais um ano adicional se o cart o de registro for enviado para a Foxtrot Com rcio Importa o e Exporta o Ltda Tel 071 358 8313 Factory Standard Option 1 Option 2 Ap ndice A CA2 CA4 Gain Sens Gain Sens X45 TISV X61 TISV X40 866V X40 1 12V X20 1 73V X20 2 24V CA6 CA9 CA12 CA18 Gain Sens Gain Sens Gain Sens Gain Sens X68 TISV X86 5 TIIN X97 5 TIIN X115 TISV X40 1 32V X40 1 66V X40 1 87V X40 2 24V X20 2 65V X20 3 32V X20 3 74V X20 447V Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Ap ndice B Diagrama em Bloco CA
26. give cable length figures in feet AWG wire gauges and in metric values Maintenance A CA Series amplifier requires no routine maintenance other than occasional cleaning or replacement of the fan intake fil ters on the rear of the amplifier This operation does not require any tools Filters must be kept clear and clean to ensure proper ventilation through the unit If the amplifier is used in an extremely dusty or smoky environment the filter should be cleaned or changed frequently and the unit should be periodically blown free using compressed air of any foreign matter that may penetrated through the filter Users will not need to make any internal adjustments to the amplifier during its lifetime There are no user serviceable parts or adjustments that require opening the power amplifier Cover removal exposes the risk of shock so refer all servicing to qualified service technicians authorized by Crest Audio User Responsibility Your CA Series amplifier is very powerful and can be poten tially dangerous to loudspeakers and operators alike It is your responsibility to read the section titled Important Precautions and make sure that the amplifier is installed wired and operated properly as instructed in this manual Many loudspeakers can be easily damaged or destroyed by overpowering especially with the high power available from a bridged amplifier Read the section on Speaker Protection and always be aware of the spe
27. h attenuators are used to con trol signal level in addition both must be adjusted to the same setting Either the 1 4 TRS or XLR input may be used NOTE The channel B input connectors XLR and or TRS may be used to loop thru the channel A signal when in par allel or bridged mono mode Use extreme caution when operating the amplifier in Bridged Mono Mode Never ground either side of the speaker cable when the amplifier is in Bridged Mono Mode both sides are hot If an output patch panel is used all connections must be isolated from each other and from the panel The recom mended minimum nominal load impedance in the Bridged Mono Mode is 4 ohms which is the equivalent to driving both channels separately at 2 ohms Driving bridged loads of less than the recommended minimums will activate the IGM cir cuitry resulting in a loss of power and may also lead to a thermal protect condition See figures on page 12 showing output connection informa tion TourClass Protection Every model in the CA Series incorporates TourClass protec tion features Derived from Crest Audio s extensive experi ence with the world s largest sound rental companies the TourClass group of circuits sets the industry standard for assured protection of internal amplifier circuits and all con nected loads ACL Active Clip Limiting At the amplifier s full power limit or clipping point ACL will be activated This is indicated by il
28. ica e Reparos 17 NO INDIO DA At Ap ndice A Especifica es Ap ndice B Diagrama em Bloco CA Ap ndice C Tabela de Dimens o dos Cabos Ap ndice D S mbolos do Painel Traseiro Legenda Ap ndice E CA18 Fun es Especiais Pag 3 CREST AUDIO CA12 CA18 Vista Frontal AN mM ED ED Ss EY o CREST 8 AUDIO EA gt E gt gt gt Altura E ED frontal SSS CA ES E CO TE l 16 sb gt 7 ES an O cp O pene 5 25 an 10 a 10 3 133mm ES 22 e a O Signa O y a gt E 1 O Protect O y gt 20 ob O Ate O amp oS E ES Ena ChB ES 5 O _ Professional Power Amplifier ES gt C gt gt y gt 55 5 YU at Largura frontal 19 483mm _ CA2 9 Vista Frontal O E ED ED E E o E E 3 CREST 8 AUDIO Altura gt CA gt frontal SS gt l 6 s c gt ronta Es gt it O Ue O il E Sa 10 s 10 3 ES 3 5 E O Sga O y gt 89mm Se gt 20 1 O Protect O y 4 E EOS CO ce CA ia ae E CD 0 ob O Active O og lt E COD JJ Ch A ChB lt SS Professional Power Amplifier O O lt Largura frontal 19 483mm z Vista Traseira Lateral Rear Side Views Dimension Information e J F CA2
29. ima para funcionamento em est reo de 2 ohms por canal Tanto a entrada de 1 4 TRS quanto XLR podem ser usadas no Canal A Modo em Paralelo Quando selecionado o Modo Paralelo um sinal aplicado entrada do Canal A ser amplificado e aparece nas sa das dos Canais e B Tanto a entrada 1 4 TRS quanto a entrada XLR podem ser usadas no Canal A Conectar as sa das do amplificador a oscilosc pios ou outros equipamentos de teste enquanto o mesmo estiver ligado no modo ponte poder danificar ambos Pag 11 CREST AUDIO SERIES Conex es de Modo Est reo NOTA Na vers o do CA 18 que pos suem os terminais de saida do tipo 5 Way Binding Posts s o dispon veis dois pares destes bornes para cada canal possibilitando conex es das caixas acusticas em paralelo Conex es no Modo em Paralelo Conex es de Modo Mono em Ponte Bridged Mono Pag 12 Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Bridged Mono Mode Bridged Mono Mode straps both amplifier channels together to make a very powerful single channel monaural amplifier One channel pushes and the other pulls equally doubling the power over that of either channel alone Signal is applied to the Channel A input only Bot
30. lifier input For more information see the sec tions on Balanced 1 4 TRS amp XLR Input Connectors Input XLR Polarity and Input Sensitivity Connecting Outputs Speakers are connected using 5 way Output Binding Posts Please note that on the CA18 two pairs of 5 way binding posts are provided for each channel so that paralleling of speakers is possible For more information see the Output Connectors and Mode Selection sections Mode Selection The three position recessed Mode Select switch located on the rear panel configures the amplifier for either Stereo Parallel or Bridged Mono Mode Amplifiers are factory con figured for Stereo Mode Stereo Mode In Stereo Mode both channels operate independently with their input attenuators controlling their respective levels Signal at Channel A s input produces output at Channel A s output while signal at Channel B s input produces output at Channel B s output Recommended minimum nominal load impedance for stereo operation is 2 ohms per channel Either the 1 4 TRS inputs or the XLR inputs may be used Parallel Mode When set to Parallel Mode a signal applied to Channel A s input will be amplified and appear at outputs for both Channels A amp B Either the 1 4 TRS input or the XLR input on Channel A may be used A Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 Conex es de Entrada Use ta
31. lumination of the Clip LED The channel gain is automatically reduced protecting the loudspeakers from potential damage from the high power continuous square waves that would otherwise be produced ACL may be activated by uncontrolled feedback oscillations improper equipment gain settings or an equipment malfunc tion upstream from the amplifier Only steady or excessive clipping not normal program transients will trigger ACL The circuit is virtually transparent in operation and full signal bandwidth is maintained CA SERIES Modo Mono em Ponte O Modo Mono em Ponte conecta os dois canais do amplifi cador para oferecer um amplificador monoaural canal nico muito potente Os canais trabalham em oposig o de fases dobrando assim a pot ncia O sinal aplicado somente na entrada do Canal A Os dois controles de volumes s o usados para controlar o n vel do sinal e devem estar ajustados para o mesmo ponto Tanto a entrada 1 4 TRS quanto a XLR podem ser usadas NOTA Os conectores de entrada do canal B XLR e ou TRS podem ser usados para conectar outros amplificadores ao Canal A loop thru quando em Modo Paralelo ou Modo Mono em Ponte Use de extremo cuidado quando operar em Modo Mono em Ponte Nunca aterre qualquer lado do cabo do alto falante quando o amplificador estiver em Modo Mono em Ponte os dois lados s o quentes Se um painel de sa da for usado todas as conex es devem ser isoladas umas das outras e do
32. m dos dissipadores de calor ultrapassar a temperatura m xima permitida o circuito sensor abrir os contatos do rel de sa da desconectando as caixas ac sticas daquele canal Se o transformador superaquecer outro circuito sensor abrir ambos os rel s das sa das at que o transfor mador esfrie a uma temperatura segura IMPORTANTE Para assegurar um timo resfriamento pe riodicamente limpe os filtros do ventilador remov veis sem ferramenta Tamb m certifique se de que haja espaco sufi ciente ao redor da frente do amplificador para permitir a sa da do ar Se o amplificador for montado em rack n o use portas ou tampas na frente do rack O ar liberado deve circu lar sem resist ncia Se os amplificadores forem alojados em rack com fundo fechado permita no m nimo o espaco de uma unidade de rack de abertura na frente do mesmo para todos os quatro modelos da S rie CA Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Connecting Inputs Use either the XLR or 1 4 inch input connectors on the rear to supply audio signals to your Crest Audio CA Series amplifier Both connectors accept balanced and unbalanced audio con nections The CA Series amplifiers are configured standard with Pin 2 hot on XLR inputs Please note that some other Crest Audio amplifiers are configured with Pin 3 hot The unused connector can be used to jumper the audio input to another amp
33. mplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Subsonic Frequencies Built in high pass filtering provides subsonic frequency pro tection for each channel In addition a relay will open if excessive subsonic energy appears at the output User Precautions Speaker Protection All loudspeakers have electrical thermal and physical limits which must be observed to prevent damage or failure Cone or compression drivers can be damaged sometimes to the point of failure from excessive power low frequencies applied to high frequency drivers severely clipped waveforms and DC voltage All CA Series amplifiers automatically protect speak ers from DC voltages and subsonic signals For more informa tion see the TourClass Protection section Mid and high frequency transducers compression driver in particular are highly susceptible to damage from overpower ing clipped waveforms or frequencies below their rated pass band When using an electronic crossover make absolutely certain that the low and mid bands are connected to the cor rect amplifiers and drivers and not accidentally connected to those for a higher or lower frequency band The amplifier s clipping point is its maximum peak output power At maximum peak output power Crest Audio CA Series amplifiers will deliver more power than many speakers can safely handle Be sure the peak power capability of the amplifier
34. mplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Ap ndice C Tabela de Dimensao dos Cabos Imperial Comprimento do Cabo Dimens o do Cabo Perda de Pot ncia Perda de Pot ncia Perda de Pot ncia sem dobras p s AWG carga de 8 ohm carga de 4 ohm carga de 2 ohm 5 18 0 81 1 61 3 2 16 0 51 1 02 2 0 14 0 32 0 64 1 28 12 0 20 0 40 0 80 10 0 128 0 25 0 51 10 18 1 61 3 2 6 2 16 1 02 2 0 4 0 14 0 64 1 28 2 5 12 0 40 0 80 1 60 10 0 25 0 51 1 01 40 18 6 2 11 9 22 16 4 0 77 14 6 14 2 5 5 0 9 6 12 1 60 3 2 6 2 10 1 01 2 0 4 0 8 0 60 1 20 2 4 80 18 11 9 22 37 16 7 7 14 6 26 14 5 0 9 6 17 8 12 3 2 6 2 11 8 10 2 0 4 0 7 1 8 1 20 24 4 7 Amplificadores de Pot ncia Crest Audio S rie CA Ap ndice C Modelos CA2 CA4 CA6 CA9 CA12 CA18 ou spo apro I At GAIN 40x 20x dBu XLR Pin 2 3 O gt Ap ndice D Ap ndice D CREST S mbolos do Painel Traseiro Legenda AUDIO Se o de Conex o de Entrada Indicador de Polaridade do Conector XLR Indicador de Polaridade do Conector TRS Interruptor de Sele o de Modo Posi o Mono em Paralelo Interruptor de Sele o de Modo Posi o Paralelo Interruptor de Sele o de Modo Posi o Est reo Interruptor de Suspens o do Terra no Chassis Posi o de Suspens o do Terra Interruptor de Suspens o do Terra no Chassis Posi o Aterrado Se
35. nnel Female XLR pin 2 configurable for pin 3 TRS tip Output Connectors per channel 5 way binding posts 2 pair on CA18 or Speakon connectors market dependent Filter Storage 20 000 uF 27 200 uF 68 000 uF 80 000 uF 140 000 uF 144 000 uF Power Supply factory configured 100V 240V 50 60Hz 100V 240V 50 60Hz 100V 240V 50 60Hz 100V 240V 50 60Hz 100V 240V 50 60Hz 100V 240V 50 60Hz Idle Current Draw 120V 1 24 1 44 1 6A 2 0A 2 84 3 04 1 8 Power Curr Draw typical music cond 120V 40 3 254 6 84 6 04 8 6A 10 5A 12 0A 1 3 Power Curr Draw cont music cond 120V 40 5 5A 10 04 13 04 16 04 23 04 25 04 Max Curr Draw continuous music cond 120V 40 9 04 15 04 18 04 21 04 30 04 36 04 Thermal Emissions 1 8 Power 42 1119 BTU hr 2030 BTU hr 2630 BTU hr 3250 BTU hr 4750 BTU hr 7125 BTU hr Thermal Emissions 1 3 Power 42 1607 BTU hr 2726 BTU hr 3713 BTU hr 4341 BTU hr 6300 BTU hr 9450 BTU hr Cooling Two rear panel variable speed DC fans filters detatchable without tools Controls LED Indicators per channel Front panel 2 attenuators magnetic circuit breaker power switch Rear panel signal ground lift amp mode switches CA18 XLR polarity amp input sens voltage gain switches Clip Limit Signal Temp DC Active Construction Steel chassis 16 gauge Double thickness in rack ear areas Dimensions Height x Width x Depth to rear rack ears Gross Weight 3 5 x 19 x 18 89 x 483 x 457mm 38 Ibs 17 25 k
36. nte de frequ ncias subs nicas excessiva na etapa de sa da Precau es do Usu rio Prote o dos Alto falantes Todos os alto falantes possuem limites el tricos t rmicos e f sicos os quais devem ser observados para prevenir perdas e danos Os cones ou drivers de compress o podem ser danifi cados pela pot ncia excessiva pela aplica o de baixa fre qu ncia em drivers de alta frequ ncia pela presen a de ondas de pico intenso e por corrente cont nua Todos os amplifi cadores da S rie CA protegem automaticamente os alto falantes da corrente cont nua e sinais subs nicos Para maiores informa es veja a se o de Prote o TourClass Alto falantes de m dia e alta frequ ncia especialmente os dri vers de compress o s o altamente suscet veis a danos por excesso de pot ncia forma o de ondas de clip ou frequ n cias que estejam abaixo da resposta de frequ ncia do transdu tor Quando estiver usando um crossover eletr nico esteja absolutamente certo de que as bandas baixas e m dias est o conectadas ao amplificador e drivers corretos e n o acidental mente conectados queles com uma banda de freqii ncia mais alta ou mais baixa O ponto de clipping do amplificador o pico m ximo de sua pot ncia de sa da Nesta situa o os amplificadores da S rie CA da Crest Audio v o liberar maior pot ncia que a maioria dos alto falantes poderia receber de maneira segura Certifique se que a capacidade m xima d
37. nto o conector de entrada XLR quanto o de 1 4 da parte posterior para fornecer os sinais de audio a seu amplifi cador Crest Audio S rie CA Os dois conectores aceitam conex es de audio balanceadas e n o balanceadas Os ampli ficadores da S rie CA tem como configura o padr o pino 2 quente nas entradas XLR Por favor observe que outros amplificadores da Crest Audio s o configurados com pino 3 quente O conector em desuso poder ser usado para ligar a entrada de audio entrada de outro amplificador Para maiores informa es veja as se es Conectores de Entradas Balanceadas tipo 1 4 TRS e XLR Polaridade das Entradas XLR e Sensibilidade de Entrada Conex es de Sa da Os alto falantes s o conectados usando conectores de sa da tipo borne 5 way binding post Para maiores informa es veja as se es Conectores de Sa da e Sele o de Modo Sele o de Modo A chave de sele o de modo de tr s posi es localizada no painel traseiro configura o amplificador para os modos est reo paralelo e mono em ponte Os amplificadores s o configurados de f brica em modo est reo Modo Est reo Em Modo Est reo ambos canais operam independentemente com seus atenuadores de volume controlando seus respectivos n veis O sinal na entrada do Canal A reproduzido na sa da do Canal A enquanto que um sinal na entrada do Canal B reproduzido na saida do Canal B A imped ncia de carga nominal m n
38. o amplificador n o seja excessiva para seu sistema de sonofletores Para assegu rar se de que o alto falante nunca receba uma pot ncia exces siva e para evitar o ponto de clipping do amplificador use um regulador externo apropriadamente ajustado ou um compres sor com raz o de 10 1 ou maior para controlar a pot ncia de sa da Use um compressor limitador para cada banda de fre qii ncia nos sistemas com crossovers eletr nicos ativos O circuito limitador de clip ACL limitar automaticamente a dura o de ondas que se mant m com amplitudes e freqii n cias constantes aplicadas aos alto falantes O amplificador ir contudo permitir a passagem de transit rios musicais nor mais Obviamente quando o amplificador atinge o clip ele estar operando com sua capacidade m xima de pot ncia Observe que alguns sonofletores s o fornecidos com seus pr prios processadores que possuem circuitos limitadores de pot ncia e consequentemente n o necessitam de um limita dor adicional Pag 15 SERIES Recommended Speaker Cabling The wire gauge charts will assist you in determining the opti mum copper wire gauge for your speaker cables Remember that the speaker cable resistance robs amplifier power in two ways through power lost directly to resistance often referred to as PR loss and through increased total load resistance which decreases the amount of power available from the amplifier The charts Appendix C
39. ound systems Optional rack mount handles are available Instala o e Montagem Quatro amplificadores da S rie CA possuem chassis com duas unidades de rack modelos 2 4 6 e 9 Os modelos 12 e 18 da S rie CA possuem chassis com tr s unidades de rack Todos os modelos adotam o padr o rack 19 e s o fornecidos com quatro orif cios de fixa o no painel frontal Os suportes de montagem posterior d o seguran a adicional e o uso destes altamente recomendado em todos os sistemas m veis de som Al as opcionais para montagem em rack podem facilmente ser adquiridas A nO SS ED E E CE a ED Clip gt S Signal ED i O Protect COD or S EE E 0 o O Active gt ESE Ch A i YN E O VU Professional Power Amplifier U O Front Panel 1 Rack Mounting Ears Two front panel mounting holes are provided on each mount ing ear 2 Optional Rack Handles Available from your authorized Crest Audio supplier 3 Fan Outlet Grills CA Series amplifiers are cooled by two rear mounted fans Cool air flows over the heat sinks and exhausts through the front grills Make sure these outlets remain clear to allow unrestricted air flow 4 AC Power Switch Circuit Breaker CA Series amplifiers have a front panel combination AC switch and circuit breaker No fuses are used If the switch shuts off during normal use push it back to the ON position once If it
40. por qualquer raz o Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Service and Repair In the unlikely event that your amplifier develops a problem it must be returned to an authorized distributor service center or shipped directly to our factory To obtain service contact your nearest Crest Audio Service Center Distributor Dealer or any of the worldwide Crest Audio offices For contact information reach Crest Audio Inc Customer Service directly at Tel 201 909 8700 USA Fax 201 909 8744 USA Because of the complexity of the design and the risk of elec trical shock all repairs should be attempted only by qualified technical personnel If the unit needs to be shipped back to the factory it must be sent in its original carton If improperly packed your amplifier may be damaged For those with Internet access please visit the Crest Audio website at http www crestaudio com CA SERIES Assist ncia T cnica e Reparos Na eventualidade de seu amplificador apresentar algum problema ele deve ser devolvido a um distribuidor autoriza do assist ncia t cnica ou enviado diretamente para nossa f brica Para obter esse servi o contate a assist ncia t cnica distribuidor ou representante mais pr ximo ou qualquer escrit rio da Crest Audio em v rias partes do mundo Para obter informa es contate o Servi o de Atendimento ao Consumidor da Crest Audio diretament
41. rature sensing circuits are operating normally The fan speed increases only as required by heat sink temperatures keeping fan noise to a minimum Under extreme thermal load the fans will force a very large volume of air through the heat sinks If either heat sink surpasses the maximum allowed temperature the sensing circuit will open the output relay disconnecting the load from that channel If the power transformer over heats another sensing circuit opens both channel output relays until the transformer cools to a safe temperature IMPORTANT To ensure optimum cooling periodically clean the amplifier fan filters removable without tools Also make certain that there is enough space around the front of the amplifier to allow the cooling air to escape If the amplifier is rack mounted do not use doors or covers on the front of the rack the exhaust air must flow out without resistance If the amplifiers are to be housed in racks with closed backs allow at least one 1 standard rack space of opening in the front of the rack for every four amplifiers Pag 10 CREST AUDIO Certifique se de que a tens o de alimenta o esteja correta e seja a mesma que a impressa na parte posterior do amplifi cador Danos causados por conectar o amplificador a uma voltagem impr pria n o s o cobertos por nenhuma garantia A n o ser que seja solicitada outro tipo de especifica o os amplificadores da Crest enviados aos clientes s o configur
42. risco de choque el trico Guarde a caixa e material de empacotamento mesmo que o equipamen to tenha chegado em boas condi es Caso algum dia voc precise enviar o equipamento use comente a caixa original de f brica Leia toda a documenta o antes de operar seu equipamento Retenha toda a documenta o para futuras consultas Para opera o adequada siga todas as instru es impressas no chassis do equipamento N o respingue gua ou outro l quido dentro ou sobre o equipamento ou opere o equipamento pisando em l quido Certifique se que a pot n cia das tomadas est em conformidade com as exig ncias de pot ncia lis tadas na parte traseira do equipamento N o use o equipamento se a fia o estiver gasta ou partida Os cabos de fornecimento de energia devem ser instalados de maneira que n o sejam pisados ou dobrados por itens colocados sobre ou contra eles prestando aten o especial nos cabos e tomadas recep Te t culos convenientes e o ponto onde eles saem do aparelho Sempre opere o equipa mento com o fio terra AC conectado ao terra do sis tema el trico Precau es devem ser tomadas com a forma de aterramento para que nenhum dos equipa mentos tenham o aterra mento anulado A tens o de alimenta o deve estar correta e ser a mesma que a impressa na parte traseira do equipa mento Danos causados pela conex o a uma vol tagem AC impr pria n o s o cobertos por n
43. rminal anel ou entra da negativa ser conectado ao terra interna mente Quando usando conectores tripolares est reo TRS certifique se de que a conex o do anel seja feita tamb m com a sa da fria do equipamento fonte de sinal ou ao terra Conex es incorretas podem causar uma perda de 6dB no n vel de sinal 1 Ground 3 Negative 2 Positive 15 Entradas e Filtros do Ventilador O ar fresco entra no amplificador atrav s das grades dos ven tiladores localizadas na parte posterior do chassis do amplifi cador Certifique se de que essas entradas n o estejam bloqueadas quando estiver instalando o amplificador ou outro equipamen to associado O ar deve circular livremente por essas entradas Os filtros do ventilador remov veis sem ferramenta compro vadamente minimizam a entrada de poeira e sujeira Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO Internal Configuration and Control Input XLR Polarity CA Series amplifiers are supplied standard with the XLR con figured as Pin 2 hot On models CA2 CA4 CA6 CA9 and CA12 an internal jumper makes it possible to alter the amplifier to Pin 3 hot NOTE This jumper is NOT user configurable Please consult your supplier or local Crest Audio service center if you wish to have the input XLR polarity changed On the CA18 an external XLR polarity switch is featured See
44. s destes s o dispon veis para que em cada canal sejam poss veis conex es de falantes em paralelo 11 Interruptor de Sele o de Modo Esse interruptor possui tr s posi es que configuram o ampli ficador para funcionamento em Est reo Paralelo ou Modo Mono em ponte Os amplificadores s o originalmente confi gurados para Modo Est reo Veja o Ap ndice D e a se o de Sele o de Modo para maiores informa es Pag 7 CA SERIES 12 Signal Ground Lift Switch The recessed signal ground lift switch factory set to the ground bottom position electrically connects signal ground to the chassis AC ground The top position lifts the amplifier s signal ground In a properly designed system for safety purposes and to minimize noise amplifiers should be connected to ground through the AC line cord Also whenev er possible the signal source equipment should share the same AC ground as the amplifier In some cases this may not be possible and a ground loop results If this happens the first step is to move the ground lift switch to the top lift position In this position the signal ground is lifted and com pletely isolated from the chassis AC ground Do not change the switch to the lift position if the amplifier and the signal source equipment are on the same AC ground Should the ground loop problem persist after the ground lift switch has been set to the lift position then the shield on
45. se 0 0 3dB 1W 8Q 20Hz 20kHz 3dB O 135kHz 20Hz 20kHz 3dB O 135kHz 20Hz 20kHz 3dB O 135kHz 20Hz 20kHz 3dB O 135kHz 20Hz 20kHz 34B G 135kHz 20Hz 20kHz 3dB 150kHz Power Bandwidth rated power at 40 1 THD N TourClass Protection 20Hz 20kHz 9dB 15dB 20Hz 20kHz 9dB 5dB 20Hz 20kHz 1 1dB 0dB 20Hz 20kHz 84dB 0dB 20Hz 20kHz 23dB 85dB ACL IGM AutoRamp short circuit DC voltage turn on off transient current inrush sub ultrasonic input 20Hz 20kHz 2dB 2dB THD N rated power 49 1kHz lt 0 01 lt 0 01 lt 0 01 lt 0 01 lt 0 01 lt 0 03 SMPTE IMD rated power 82 60 Hz amp 7kHz lt 0 01 lt 0 01 lt 0 01 lt 0 01 lt 0 01 lt 0 01 Damping Factor 10 400Hz at 89 368 1 550 1 400 1 700 1 800 1 800 1 Input CMRR 1kHz gt 60 dB gt 60 dB gt 60 dB gt 60 dB gt 60 dB gt 70dB Standard Input Sensitivity rated power at 89 0 775V 0 775V 0 775V 0 775V 0 775V 0 775V Standard Voltage Gain rated power O 80 X45 X61 X68 X86 5 X97 5 X115 Input Impedance balanced unbalanced gt 20kQ gt 10kQ gt 20kQ gt 10kQ gt 20kQ gt 10kQ gt 20kQ gt 10kQ gt 20kQ gt 10kQ gt 20kQ gt 10kQ Hum and Noise A weighted full power at 49 105dB 105dB 105dB 105dB 105dB 115dB Crosstalk A weighted full power at 40 gt 60dB gt 60dB gt 60dB gt 60dB gt 60dB gt 80dB Class AB AB H H H H Input Connectors per cha
46. tes at the clipping threshold Continuous illumination also indicates that ACL Active Clip Limiting protection cir cuitry is engaged 7 Active LED Indicates that AC power is connected and the amplifier is turned on 8 Protect LED Indicates that the channel is in Protect mode speakers discon nected by output relay 9 Input Attenuators Two input attenuators adjust level for their respective amplifi er channels In Bridged Mono Mode both attenuators are used to control signal level and must be adjusted to the same setting terra ou a qualquer outra saida quente vermelha Nunca conecte uma saida quente vermelha ao CA SERIES 6 O LED de Clip Acende no limiar maximo O brilho intenso e continuo tam b m indica que o circuito de prote o ACL Limitador Ativo de Clip foi acionado 7 O LED Active Indica que a corrente AC est conectada e que o amplificador est ligado 8 LED de Protec o Indica que o canal est no Modo de Prote o alto falantes desconectados pelo rel de sa da 9 Controles de Volume Dois controles de entrada ajustam o n vel para seus respec tivos canais No Modo Mono em Ponte ambos atenuadores s o usados para controlar o n vel do sinal e devem ser ajusta dos ao mesmo ponto Rear Panel 10 Output Connectors CA Series amplifiers are supplied with 5 way Binding Post connectors Connection to the binding posts can be made with bar
47. thermal circuits will automatical ly protect the amplifier The IGM circuit senses the short cir cuit as an extremely stressful load condition and attenuates the signal protecting the channel s output transistors from over current stress If the short circuit remains the load will be disconnected by the thermal protection circuitry output relay opens DC Voltage Protection If an amplifier channel detects DC voltage at its output termi nals the output relay will immediately open to prevent loud speaker damage The Protect LEDs will light Pag 14 CREST AUDIO Sensor de Impedancia IGM IGM Modula o Instant nea de Ganho um circuito ino vador que permite ao amplificador operar com seguran a em cargas t o baixas quanto 2 ohms Quando o amplificador detecta uma carga que sobrecarregue a etapa de sa da o cir cuito IGM ajusta o ganho do canal a um n vel seguro Como o ACL o circuito IGM inaud vel em uso normal Ademais se uma imped ncia extrema e cont nua for encontrada o rel de sa da do amplificador se abrir Prote o AutoRamp Auto Ramp opera toda vez que o amplificador for ligado ou reativado ap s a corre o de uma condi o de prote o Essa caracter stica exclusiva da Crest Audio aumenta gradual mente o ganho do sinal que enviado para os controles de volume evitando assim um esfor o desnecess rio sobre os alto falantes Prote o T rmica Se a temperatura do dissipador de
48. ual do proprietario do Amplificador de Pot ncia Introduction 5 Unpacking 5 Installation and Mounting 6 Front Panel 6 Rear Panel 7 Internal Configuration and Control 9 Operation 9 Connecting Power 9 Circuit Size Requirements 9 Cooling System and Requirements 10 Connecting Inputs 11 Connecting Outputs 11 Mode Selection 11 Stereo Parallel Bridged Mono Connections 12 TourClass Protection Features 13 User Precautions 15 Speaker Protection 15 Recommended Speaker Cabling 16 Maintenance 16 User Responsibility 16 Service and Repair 17 Appendix A Specifications Appendix B CA Block Diagram Appendix C Wire Gauge Charts Appendix D Rear Panel Symbols Legend Appendix E CA18 Special Functions Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 indice Introdu o 5 Desempacotamento Instala o e Montagem Painel Frontal Painel Traseiro Controle e Configura o Interna Funcionamento Tens o de Alimenta o Dimens es Requeridas do Circuito 9 Sistema de Resfriamento e suas Exig ncias 10 Conex es de Entradas 11 Conex es de Sa das 11 Sele o de Modo 11 Conex es Est reo Paralelo Mono em Ponte 12 Caracter sticas da Prote o TourClass 13 Precau es do Usu rio 15 Prote o dos Alto falantes 15 Cabos Recomendados para Caixas Ac sticas 16 Manuten o 16 Responsabilidade do Usu rio 16 Assist ncia T cn
49. will not stay on the amplifier needs servicing 5 Signal LED Tlluminates to indicate that a signal above a minimum thresh old is present at the amplifier input and that the signal is being amplified Pag 6 Painel Frontal 1 Suportes de Montagem em Rack Dois orif cios para fixa o no painel frontal s o oferecidos para cada aba do suporte de montagem 2 Al a opcional para Rack Dispon vel em seu revendedor autorizado da Crest Audio 3 Grelha de sa da do ventilador Os amplificadores da S rie CA s o resfriados por dois venti ladores fixados na parte de tr s O ar fresco corre pelo dissi pador de calor e sai pela grelha frontal Certifique se de que essas sa das estejam livres para permitir a circula o irrestrita do ar 4 Interruptor de Corrente AC Disjuntor Os amplificadores da S rie CA t m uma combina o de inter ruptor AC e disjuntor no painel frontal N o s o usados fus veis Se o interruptor desligar durante o uso normal empurre o bot o novamente para a posi o ON uma vez Se ele n o permanecer nessa posi o sozinho o amplificador precisa da Assist ncia T cnica 5 LED de Sinal Ele acende para indicar que o sinal abaixo do limite m nimo est presente na entrada do amplificador e que o sinal est sendo amplificado Amplificadores de Pot ncia Crest Audio S rie CA Modelos CA2 CA4 CA6 CA9 CA12 CA18 CREST AUDIO 6 Clip LED Tllumina