Home
        Instruction and maintenance manual Livret d
         Contents
1.       SCH       De        O PROFESSIONALE                DAL 1956            Manuale d uso e manutenzione  Instruction and maintenance manual  Livret d instruction et entretien  Bedienungs und Wartungsanlertung    rn I SURGELATORI RAPIDI  AST CHILLERS   SHOCK FREEZERS   CELLULES       REFROIDISSEMENT   SURGELATION RAPIDE  SCHNELLKUHLER   SCHOCKFROSTGERATE    ABF 20P 40P 80P 120P  RIV    Capitolo 1            ED AVVERTENZE GENERALI  Section 1 STANDARDS AND GENERAL WARNINGS  Chapitre 1 NORMES ET AVERTISSEMENTS GENERAUX  Kap  1 NORMEN UND ALLGEMEINE HINWEISE    1 1 DICHIARAZIONE DI CONFORMITA    1 1 DECLARATION OF CONFORMITY  1 1 DECLARATION DE CONFORMITE   1 1 KONFORMITATSERKLARUNG       DICHIARAZIONE CE DI CONFORMITA   CE DECLARATION OF CONFORMITY  DECLARATION CE DE CONFORMITE   KONFORMITATSERKLARUNG       NOI   THE COMPANY   NOUS   DIE FIRMA  EVERLASTING S R L    Fabbrica Frigoriferi Industriali  S S  Cisa km  161   46029 SUZZARA   MN     ITALIA    Dichiariamo sotto la nostra esclusiva responsabilit   che il prodotto ABBATTITORE  Declares  under its own sole responsibility  that the product designated BLAST CHILLER  D  clarons sous notre responsabilit   exclusive que le produit CELLULE DE REFROIDISSEMENT    Erkl  rt unter der eigenen und ausschlie  lichen Verantwortung  da   das Produkt SCHNELLKUHLER       Numero di serie  Serial number  Num  ro de s  rie  Seriennummer             al quale questa dichiarazione si riferisce     conforme alle seguenti direttive europee    to wh
2.      Premere il tasto Menu per uscire dal Menu oppure Start Stop per attivare immediatamente il ciclo di conservazione     Men   03   Programma in memoria   Se viene premuto il tasto Enter si entra nella selezione dei programmi che sono suddivisi in due categorie  programmi  memorizzati dall utente e programmi presettati non modificabili e il programma  sul display compare    Programmi Utente   Se viene premuto il tasto Enter per entrare nella selezione dei programmi Utente  1   20   sul display compare il  numero del programma con l indicazione del tipo di ciclo memorizzato  gli altri possono essere selezionati con i tasti  Up e Down  Premere il tasto Menu per uscire dal Menu senza selezionare il programma oppure Start Stop per attivare  immediatamente il ciclo di abbattimento selezionato    Premendo Enter si seleziona il programma e il dispositivo attende in Stand By    Programmi Preset   Se viene premuto il tasto Enter per entrare nella selezione dei programmi Preset  21   29   sul display compare il  numero del programma con il nome  gli altri possono essere selezionati con i tasti Up e Down    ITALIANO          20 40 80 120             programmi preselezionati sono i seguenti                                                           Prog Nome del programma Positivo o negativo an Hard Fao tempo  21  Abbattimento carni Positivo Temperatura Si  2  C 120 min  22   Abbattimento creme Positivo Tempo No  2  C 90 min  23   Abbattimento pasticci Positivo Tempo No  2  C 90 min  24
3.     225 175       Fluido refrigerante  Cooling gas   Gaz r  frig  rant  K  ltemittel    R404 A    R404 A    16    ENGLISH             20 40 80 120              Dimensioni esterne Lx Px Hmm  External dimensions Lx Dx Hmm  Dimensions ext  rieures Lx Dx Hmm  Au  enma  e B xT x Hmm    ABF 40 C    ABF 40 P      1   1 1560x1505    2420    2   2 1560x1650 x 2420       Dimensioni interne utili LxPxH mm  Useful internal dimensions Lx Dx Hmm  Dimensions int  rieures utiles Lx Px Hmm  N  tzliche InnenmaBen BxTx Hmm    C1 P1 821x1141 x 2220  C2 P2 821    1373 x 2220                      di carico   Load capacity   Capacit   de chargement  Belastungsfahigkeit         49 ON ID     20 GN2 1       40 60x40   20 60x80    40 GN1 1    1   20 GN2 1    40 60x40    1   20 60x80       Resa kg per ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     907 43  C    150    220       Resa kg per ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     90    18  C    120    170       Potenza frigorifera W   Refrigerating power W n     Puissance frigorifique     23 3   C  544  C  Gefrierleistung W    12920    16720       Potenza max assorbita kw  Max absorption kw  Absorption max kw  Max Energieverbrauch kw    9 7    15 8       Potenza nominale compressore HP  Nominal compressor power Hp  Puissance nominale compresseur Hp  Kompressorsnominalleistung HP    7 5    10       Tensione alimentazione  Voltage   Tension d alimentation  Spannung    400N 3 50    400N 3 50       Temperatur
4.     TL at Ta    BL  NE       4  E KV            BI                    CR i RO             BI  KS  ella              LJ  COMANDO ELETTRONICO  CELLA ABBATTITORE       ELECTRONIC COMMAND    BLAST CHILLERS ROOM  ALARM  By Client  CON UNITA    CONDENSATRICE     WITH CONDENSATING UNIT             PNR    18          19    ENGLISH             20 40 80 120           46029 SUZZARA  MN    ITALY   5 5  Cisa      161  Tel 0376 521800  4                   Telefax 0376 521794                     Nttp   www everlasting it   E mail everlasting everlasting  it    Fy o  EVERLASTING EVERLASTING s r l  age       
5.    Abbattimento preparati Positivo Tempo No  2  C 90 min  25  Abbattimento prodotti ittici Positivo Tempo Si  2  C 90 min  26  Abbattimento prodotti avicoli   Positivo Tempo Si  2 90 min  27  Abbattimento verdure Positivo Tempo No  2  C 90 min  28  Cong temper prodotti generici   Negativo Temperatura Si  22  C 240 min  29  Congtempo prodotti generici   Negativo Tempo Si  22  C 240 min    Men   04   Avvio sbrinamento   Se viene premuto il tasto Enter si accede alla richiesta start sbrinamento    Premendo il tasto Enter si esce dal menu e lo sbrinamento non viene attivato  Premendo il tasto Up si attiva uno  sbrinamento se    in corso una fase di conservazione    Premendo il tasto Start Stop lo sbrinamento viene disattivato    Nota  dal menu principale    possibile attivare immediatamente uno sbrinamento  premendo per 5 secondi il tasto  Enter     Men   05   Impostazioni   Se viene premuto il tasto Enter  viene richiesta la password per accedere ai sottomen   di impostazione e di Service   Selezionare la password con i tasti Up e Down e premere Enter    La password impostata     19     Menu 06  Regolazione orologio   Se viene premuto il tasto Enter si entra nella modalit   di impostazione orologio  La cifra lampeggiante pu   essere  modificata tramite i tasti Up e Down   Premendo il tasto Enter si conferma il valore e si passa al dato successivo   Premere il tasto Menu per tornare al Menu Principale     Menu 07  Memorizzazione di un programma   Se viene premuto il tasto Enter s
6.    LI 5 H          20 40 80 120           Chilling Freezing cycles   The compressor remains deactivated until the chamber temperature is over 90  C    The evaporator fan remains deactivated until the chamber temperature is over 70  C    A chilling freezing cycled starts only when the core probe detects a temperature lower than 70  C     Temperature based chilling or freezing   To activate this cycle  enter Menu Set and select a temperature based chilling freezing  then push the Start Stop  key  In this mode of operation the compressor adjusts itself on the planned SetPoint  referred to the chamber probe   The normally acknowledged duration for this phase is the planned one  and it is expressed in minutes  This operative  phase ends when the core probe temperature reaches the set value  During the execution of this phase the display  shows the chamber probe temperature and the core probe temperature  The chilling freezing phase ends when the  temperature detected by the core probe reaches the planned set  then the system automatically sets in storage mode   If the chilling freezing has not ended within the planned duration  the chilling freezing continues but the writing  TimeOut flashes on the display  By pushing the Up key  the time elapsed from the beginning of the chilling freezing  is displayed  After the chilling freezing  the storage phase takes place automatically    Time based chilling or freezing To activate this cycle  enter the Menu Set and select a time based chil
7.    The chilling freezing phase starts when the temperature detected by the core probe reaches the set value  Then  the storage takes place automatically  If the chilling freezing has not ended within the set time  the chilling freezing  continues  but the writing TimeOut flashes on the display  by pushing the Up key  the time elapsed from the beginning  of the chilling freezing is displayed  After the chilling freezing  the storage phase takes place automatically     Time based Hard chilling freezing   To activate this chilling freezing cycle  enter the Menu Set and select a time based Hard chilling freezing  then push  the Start Stop key  In this mode of operation  the chilling freezing is divided into two phases  in the first phase  called  Hard  the compressor adjusts itself on the Setpoint  referred to the chamber probe  The duration of the Hard phase  is the percentage  set on 60   of the total time  During the execution of this phase the display shows the chamber  temperature and the remaining time  In the second phase  called Soft  the compressor adjusts itself on the Setpoint   referred to the chamber probe  The duration of the Soft phase is the remaining of the total time    During the execution of this phase the display shows the chamber temperature and the remaining time    At the end of the chilling freezing phase the storage phase takes place automatically     Positive and negative storage   During the positive storage phase  the display shows  Cell  5 Cons   The
8.   but can be silenced by pushing the Enter key     14             LI 5 H          20 40 80 120           Evaporator Probe   The probe allows to end a defrost and to activate the Evaporator Fans  A probe breakdown causes an Evaporator Probe  breakdown Alarm The buzzer and the alarm relay activate  The alarm writing ALL Sonda Evap flashes on the display   The defrost end by time and the activation of the Evaporator Fans take place regardless of the evaporator probe  The  buzzer rings for a minute m but can be silenced by pushing the Enter key  The alarm is immediately called off at the  end of the breakdown and the alarm relay deactivates     Core probe   The core probe is used for temperature based core chilling freezing cycles  A breakdown of the core probe causes a  Core Probe Breakdown Alarm only if a temperature based chilling freezing cycle is under way  in this case  the cycle  automatically converts into a time based cycle  The display shows the flashing alarm writing  ALL Sonda Spill   By pushing the Enter key  this visualization disappears  and the prospective conservation phase takes place  normally     Uninserted core probe alarm   This alarm activates if the core probe insertion test fails during a temperature based chilling freezing cycle  The cycle  automatically converts into a time based cycle and the display shows  ALL Insert Spill   By pushing the Enter key  the signal disappears     Menu 09  Print  optional with printer    Access the stored chilling freezing
9.   espressa in minuti     La fase di abbattimento termina quando la temperatura rilevata dalla sonda a spillone raggiunge il set impostato e si  ha il passaggio automatico in conservazione     Tasto avvio rapido Abbattimento negativo a temperatura   Con la scheda in Stop  premere 5 secondi il Tasto Down ed inizia immediatamente un ciclo di abbattimento negativo  standard a temperatura  Il compressore regola sul SetPoint impostato  riferito alla sonda cella  La durata  normalmente ammessa per tale fase    quella massima impostata ed    espressa in minuti    La fase di abbattimento termina quando la temperatura rilevata dalla sonda a spillone raggiunge il set impostato e si  ha il passaggio automatico in conservazione     Sbrinamento  I cicli di sbrinamento vengono gestiti automaticamente dalla scheda elettronica al termine di ogni ciclo e manualmente  dal Men   04 Avvio Sbrinamento manaule    Verifica inserimento spillone   All   inizio di un ciclo di abbattimento a temperatura spillone  viene eseguito un test per verificare se la Sonda Spillone     correttamente inserita nel prodotto     test spillone    organizzato su due livelli  il primo denominato veloce o a soglia  ed il secondo denominato lento o differenziale     Test a soglia  Durante il test veloce vengono eseguiti cinque confronti tra le temperature della cella e dello spillone  se almeno in tre    delle cinque verifiche i rilievi rispettano la seguente relazione   Tspillone   Tcellal  gt  5  C   lo spillone    consi
10.  4       Potenza nominale compressore HP  Nominal compressor power Hp  Puissance nominale compresseur Hp  Kompressorsnominalleistung HP    Tensione alimentazione  Voltage   Tension d alimentation  Spannung    15 20    400N 3 50 400N 3 50       Temperatura ambiente max   C  Classe  Room temperature max        Class  Temp  rature ambiance max   C   Classe  Raumtemperatur max   C  Klasse    Peso cella   unit   condensatrice  Cold room   condensing unit weight  Poids chambre froide   unit   condensatrice     43  C T  43  C T    720 436 800 475    Kiihlzellegewicht Kondensationseinheitsgewicht       Fluido refrigerante  Cooling gas   Gaz r  frig  rant  K  ltemittel    R404 A R404 A  17       ENGLISH          Dimensioni esterne Lx Px Hmm  External dimensions Lx Dx Hmm  Dimensions ext  rieures Lx Dx Hmm  AuBenmaBe BxTxH                  20 40 80 120           ABF 120C ABF120P    C1 P1 1560x3905 x 2420  C2 P2 1560 x 4050 x 2420       Dimensioni interne utili Lx Px H mm  Useful internal dimensions Lx Dx Hmm  Dimensions int  rieures utiles Lx Px Hmm  N  tzliche InnenmaBen BxTxH         C1 P1 821x3541 x 2220  C2 P2 821x3773 x 2220       Capacit   di carico   Load capacity   Capacit   de chargement  Belastungsf  higkeit         40      3  40 NI  X 20 GN2 1    20 GN2 1       40 60x40     40 60x40   20 60x80 20 60x80       Resa kg per ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     907 43  C    420 630       Resa kg per ciclo   Output kg for blast chilling  Rendement k
11.  Sonda Spillone    utilizzata per i cicli di abbattimento per temperatura al cuore  Un guasto della sonda spillone  provoca un Allarme guasto della Sonda Spillone solo se    in corso un ciclo di abbattimento a temperatura  in tal  caso il ciclo automaticamente commuta a tempo  Sul display lampeggia la scritta di allarme ALL Sonda Spill  Premendo il tasto Enter la visualizzazione rientra  l eventuale fase di conservazione avviene normalmente     Allarme spillone non inserito   Questo allarme si attiva se fallisce il test di inserimento spillone durante un ciclo di abbattimento a temperatura  il  ciclo automaticamente commuta a tempo e sul display compare l indicazione  ALL Insert Spill   Premendo il tasto Enter la segnalazione scompare     Menu 09  Stampa  optional con stampante    Se viene premuto il tasto Enter si accede alla richiesta della stampa dei cicli di abbattimento memorizzati   Premendo il tasto Enter si esce dal menu e la stampa non avviene  Premendo il tasto Up inizia la stampa dei cicli di  abbattimento memorizzati con un tempo di campionamento programmato     Menu 10  Ingressi   Uscite   Se viene premuto il tasto Enter si entra nella modalit   di visualizzazione ingressi e uscite  Tramite i tasti Up e Down si  scorrono le grandezze da visualizzare    valori della temperature di Cella e Spillone  il valore della sonda evaporatore e  lo stato degli ingressi digitali e dei Rel      Menu 11  Sterilizzazione  optional con lampada UV sterilizzatrice   Per utilizzare 
12.  by pushing the Menu key     Menu 08  Alarms list   Enter the alarms visualization mode by pushing the Enter key  It is possible to store up to 30 alarms with their  respective information  The memory is circular  once 30 alarms are reached  the new alarm deletes the oldest  If no  alarms are stored  the display shows NO DATA  If some alarms are stored  the display shows the start time of the last  occurred alarm with a progressive alarm number from A01 to A30  By pushing the Enter key  further information  about the alarm are displayed  maximum and minimum temperature  duration  call the SERVICE  time of alarm end if  the alarm has ended  or it indicates that the alarm is still under way  The other stored alarms can be selected through  the Up and Down keys     Push the Menu key to go back to the Main Menu     Chamber probe   In Stand By mode  the display shows the temperature value detected by the probe  A probe breakdown causes a  Chamber Probe Alarm  The buzzer and the alarm relay are activated and the display shows the flashing error writing  ALL Sonda Cella     A chilling freezing cycle is immediately interrupted  and the device sets in Stand By mode preventing any new  start  on the contrary  during the storage phase the compressor activates cyclically with a Duty Cycle  The buzzer  rings for a minute  but can be silenced by pushing the Enter key  At the end of the breakdown the alarm is called off  automatically and the alarm relay is deactivated     High Temperature 
13.  compressor adjusts itself on the Setpoint  referred to the chamber probe  This phase ends by pushing the Start   Stop key and the device sets in Stand By mode     Key for quick start of temperature based chilling   With the board on Stop mode  push the Up key for 5 seconds  A temperature based standard chilling cycle starts  immediately  The compressor adjusts itself on the planned Setpoint  referred to the chamber probe  The normally  acknowledged duration of this phase is the longest that has been set  and is expressed in minutes    The chilling phase ends when the temperature detected by the core probe reaches the planned set  then the storage  phase takes place automatically                    LI 5 H          20 40 80 120           Key for quick start of temperature based freezing   With the board on Stop mode  push the Down key for 5 seconds  A temperature based standard freezing cycle starts  immediately  The compressor adjusts itself on the planned Setpoint  referred to the chamber probe  The normally  acknowledged duration of this phase is the longest that has been set  and is expressed in minutes    The chilling phase ends when the temperature detected by the core probe reaches the planned set  then the storage  phase takes place automatically     Defrost  The defrost cycles are automatically managed by the electronic board at the end of each cycle and manually by Menu  04 Manual Defrost Start     Probe insertion check   At the start of a temperature based chilling 
14.  cycles printing request by pushing the Enter key  Exit the menu by pushing the  Enter key  and the printing does not take place  By pushing the Up key  the stored freezing chilling cycles printing  starts with a programmed sampling time     Menu 10  Inputs Outputs   Enter the input and output visualization mode by pushing the Enter key  Scroll the values to be visualized by pushing  the Up and Down keys  chamber probe and core probe temperature  evaporator probe temperature and the digital  inputs and relay status     Building characteristics   Mono block construction with inside and outside in stainless steel AIS  304 18 10   inside with rounded corners  and moulded bottom   CFC and HCFC free insulation by high density polyurethane foam with sslide way        wire   shelfes supports easily removable without using tools   internal fitting for GN1 1 and GN2 3 containers sair cooled  refrigerating unit measuring of temperature by means of core probe  from  90   to  3  C during blast chilling process  and from  90   to  18  C during freezing process   electronic control panel   possibilities of choice between    soft    and     hard    blast chilling cycles depending on the delicacy of the goods and of choice between prearranged cycles sself   closing doors with easily replaceable magnetic gaskets   adjustable in height stainless steel feet    voltage 230 1 50  and 400 3 50     15       Dimensioni esterne Lx Px Hmm  External dimensions Lx Dx Hmm  Dimensions ext  rieures L x Dx 
15.  temperatura con sonda al cuore in abbattimento da  90   a  3  C  ed in congelazione rapida da  90       18  C   pannello comandi elettronico con display LCD   porte autochiudenti Je  macchine vengono normalmente spedite smontate             LI S H          20 40 80 120                                   ABF 20 P ABF 40 P ABF 80 P ABF 120 P    Door           a    start stop        GENERAL DESCRIPTION   The card allows a control for blast chillers   freezers and allows blast chilling and freezing cycles with temperature  control at the heart of the product and simple time regulated cycles  A conservation cycle follows to each blast  chilling freezing cycle  A manual and or automatic defrosting cycle is available    If the chosen pattern allows it  it is possible to connect a printer for printing on line temperature and alarm values     Description of blast chiller shock freezer LCD controls Keys    ON OFF key 6    By pushing the ON OFF key for 5 seconds  the controller turns off and the word OFF with flashing cursor is displayed   By subsequently pushing the ON OFF key the controller turns on again and sets in Stand By mode     Enter key       It allows to access menus or to select a parameter     Menu key       It allows to access the main menu or to return to the previous menu     Up and Down keys    GA    It allows to scroll the various menus or to change the parameter values     Start Stop key       It allows to start a chilling freezing cycle or to stop it     10          
16. 40 80 120           Menu 01  Cycle settings   Enter the chilling freezing cycle setting mode by pushing the Enter key  The display shows  Abbattimento Negativo   Positivo  Chilling Freezing   Enter in the modification mode by pushing the Enter key  The setting type flashes  and it  is possible to modify this value by pushing the Up and Down keys  By pushing the Enter key  the set value is confirmed  and the datum does not flash anymore  By pushing the Up and Down keys  it is possible to pass on to the next settings   Time based Chilling Freezing  Temperature based Chilling Freezing  Cycle duration and Setpoint Temperatures   Push the Menu key to exit the Menu  or the Start Stop key to immediately start a chilling freezing cycle     Note  during a chilling freezing cycle it is possible to enter the Menu Set to see the settings  but it is not possible to  modify them     Menu 02  Storage   Enter the Storage mode to start a storage only cycle by pushing the Enter key  The display shows  Conservazione   storage     Enter in the modification mode by pushing the Enter key  The setting type flashes  and it is possible to modify this  value  Negative Positive  by pushing the Up and Down keys  By pushing the Enter key  the set value is confirmed  and the datum does not flash anymore  By pushing the Up and Down keys  it is possible to pass on to Set Chamber in  storage mode  By pushing the Enter key  the value is confirmed and the datum does not flash anymore    Push the Menu key to ex
17. Alarm   During the positive  negative  storage phase  if the temperature settles over the alarm threshold value for over 30  minutes  and the delay from the storage phase start or from the end of a defrost has run out  a High Temperature  Alarm activates  The alarm writing Alta Temp Cella flashes on the display  The alarm is stored  the buzzer and the  alarm relay activate  The buzzer rings for a minute  but can be silenced by pushing the Enter key  The alarm is called off  immediately when the temperature returns under the limit     Low Temperature Alarm   During the positive  negative  storage phase  if the temperature settles under the value for over 30 minutes  and the  delay from the storage phase start or from the end of a defrost has run out     Low Temperature Alarm activates  The  alarm writing Bassa Temp Cella flashes on the display  The alarm is stored  the buzzer and the alarm relay activate  The  buzzer rings for a minute  but can be silenced by pushing the Enter key  The alarm is called off immediately when the  temperature returns over the limit     Black Out Alarm   If the board lacks power during the positive  negative  storage phase  and if when the power returns the temperature  is higher than the set value     Black Out Alarm is activated because of a lack of power  The alarm writing ALL BlackOut  flashes on the display  The times of the lack of power and of its return are stored  the buzzer and the alarm relay are  activated  The buzzer rings for a minute
18. Hmm  AuBenmaBe BxTxH            ABF 20 C    950x1190 x 2180    ABF 20 P    950x1190 x 2180       Dimensioni interne utili LxPxH mm  Useful internal dimensions Lx Dx Hmm  Dimensions int  rieures utiles Lx Px Hmm  N  tzliche InnenmaBen BxTxH         607    716 x 1860    607    716 x 1860                      di carico   Load capacity   Capacit   de chargement  Belastungsfahigkeit         20 6           20 60x40    1  20 GN     20 60x40       Resa kg per ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     907 43  C    80    110       Resa kg per ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     90    18  C    60    85       Potenza frigorifera W   Refrigerating power W S     Puissance frigorifique     23 3   C 4544 C  Gefrierleistung W    5370    7200       Potenza max assorbita kw  Max absorption kw  Absorption max kw  Max Energieverbrauch kw    4 5    5 6       Potenza nominale compressore HP  Nominal compressor power Hp  Puissance nominale compresseur Hp  Kompressorsnominalleistung HP    4 5       Tensione alimentazione  Voltage   Tension d alimentation  Spannung    400N 3 50    400N 3 50       Temperatura ambiente max        Classe  Room temperature max        Class  Temp  rature ambiance max   C  Classe  Raumtemperatur max   C   Klasse     43  C T     43  C T       Peso cella   unit   condensatrice  Cold room   condensing unit weight  Poids chambre froide   unit   condensatrice    190 173    Kiihizellegewicht  Kondensationseinheitsgewicht
19. a ambiente max   C  Classe  Room temperature max        Class  Temp  rature ambiance max   C   Classe  Raumtemperatur max   C Klasse     43  C T     43  C T       Peso cella   unit   condensatrice  Cold room   condensing unit weight  Poids chambre froide   unit   condensatrice    400 243    Kihizellegewicht  Kondensationseinheitsgewicht    440 354       Fluido refrigerante  Cooling gas   Gaz r  frig  rant  K  ltemittel    R404 A    R404 A    Dimensioni esterne Lx Px Hmm  External dimensions Lx Dx Hmm  Dimensions ext  rieures Lx Dx Hmm  Au  enma  e B xT x Hmm       ABF 80 C    ABF 80 P      1   1 1560 x 2705    2420    2   2 1560    2850 x 2420       Dimensioni interne utili L x Px H mm  Useful internal dimensions Lx Dx Hmm  Dimensions int  rieures utiles Lx Px Hmm  N  tzliche InnenmaBen Bx Tx Hmm    C1 P1 821x2341 x 2220  C2 P2 821 x 2573 x 2220       Capacit   di carico   Load capacity   Capacit   de chargement  Belastungsfahigkeit    ax 40 6 11      40 GN1 1     20 GN2 1    20 GN2 1  2  40 60x40 40 60x40   20 60  80 20 60  80       Resa kg        ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     907 43  C    340 420       Resa kg per ciclo   Output kg for blast chilling  Rendement kg   Leistung kg     90    18  C    280 330       Potenza frigorifera W  Refrigerating power W  Puissance frigorifique W 23  Gefrierleistung W      C  54 4   C    23910 27980       Potenza max assorbita kw  Max absorption kw  Absorption max kw  Max Energieverbrauch kw    17 8 19
20. ased  ES   generig Freezing Temperature Yes  22  C 240 min  products   29   ER  freezing  generic Freezing Time Yes  22  C 240 min  products   Menu 04  Defrost Start    Enter the defrost start request by pushing the Enter key  Exit the menu by pushing the Enter key  defrost will not be  activated  By pushing the Up key  defrost is activated if a storage phase is under way  By pushing the Start Stop key  the defrost is deactivated    Note  it is possible to immediately start a defrost cycle from the main menu by pushing the Enter key for 5 seconds     Menu 05  Settings   By pushing the Enter key  a password is requested to access the setting s and service submenus  Select the  password with the Up and Down keys and push the Enter key    The set password is  19     13             LI 5 H          20 40 80 120           Menu 06  Clock Set   Enter the clock set mode by pushing the Enter key  The flashing number can be modified through the Up and Down  keys  Confirm the value then pass on to the next datum by pushing the Enter key    Push the Menu key to go back to the Main Menu     Menu 07  Program storage   Enter the storage mode for a previously set chilling freezing program by pushing the Enter key  The display shows the  program number  indicating whether the program has already been stored or it is free  Scroll all the programs from  1 to 20 by pushing the Up and Down keys  To store a program at the intended number push the Enter key  Exit the  menu without saving the program
21. ation of this test is set at 567 while the increment factor is fixed and equal to 1  C  in this case too  8 detections  are performed  the test is passed when in at least 6 cases the relation was verified     Setting visualization menu   With the device in Stand By mode  push the Enter key and enter the setting visualization menu  Cycle settings are  displayed  With the Up and Down keys it is possible to scroll further information  such as the chamber SetPoint in  chilling freezing mode  the chamber SetPoint in storage mode   the value of the core probe chamber  the maximum  allowed time in the Hard and Soft phase and the chamber SetPoint in Hard and Soft chilling  freezing modes  Exit the  setting visualization menu by pushing the Enter key  The device returns to the previous conditions    Note  the chilling  freezing cycle settings cannot be modified by this menu     Menu description  From the main window  press the Menu key and select the needed menu with the Up and Down keys     Menu 01 Set Chilling Freezing cycle setting menu  Menu 02 Storage Storage only setting menu   Menu 03 Programs Selection of a stored program   Menu 04 Defrost Defrost activation menu   Menu 05 Settings Device settings menu   Menu 06 Clock set Clock setting menu   Menu 07 Data storage Storage of a set program   Menu 08 Alarms Visualization of stored alarms   Menu 09 Print Stored cycles print menu   Menu 10 Inputs Outputs Visualization of Input and Output status    12             LI 5 H          20 
22. derato inserito nel prodotto da surgelare  In questo caso la successiva fase di test non viene  eseguita    La durata di questa fase    di circa 50 secondi visto che ogni test    eseguito con una cadenza di 10 sec  teoricamente  questo tipo di verifica dovrebbe risolvere la maggior parte dei casi che si possono presentare  infatti solo nell ipotesi  di prodotto alla stessa temperatura della cella  dovrebbe essere necessario eseguire il test differenziale  L esecuzione  di pi   verifiche consente di avere un test affidabile e versatile  ovvero che non vincoli l utilizzatore ad una rigida  procedura operativa     Test differenziale   Il test differenziale si basa sul fatto che raffreddando la cella  la temperatura di quest ultima scende pi   rapidamente  di quella all interno del prodotto a causa dell inerzia termica di quest ultimo  questa situazione viene riassunta  matematicamente dalla relazione riportata di seguito  in altre parole    Il test verifica quindi che il At tra l esterno       l interno del prodotto aumenti      At attuale   Dt precedente    gt  1  C  La durata di questo test    fissata    56  mentre il fattore di incremento    fisso e pari a 1  C  Anche in questo caso vengono  eseguite otto misure  il test viene superato quando in almeno 6 casi si    riscontrato che la relazione    verificata     Menu di visualizzazione delle impostazioni   Con il dispositivo in Stand By  premendo il tasto Enter  si entra nel menu di visualizzazione delle impostazioni e sul  di
23. di sterilizzazione    Men   01   Impostazione del ciclo   Se viene premuto il tasto Enter si entra nella modalit   di impostazione del ciclo di abbattimento e sul display viene  visualizzato  Abbattimento Negativo Positivo  Premendo Enter si entra in modifica e il tipo di impostazione diventa  lampeggiante  con i tasti Up e Down sar   possibile modificarne il valore  La pressione del tasto Enter conferma il  valore impostato e il dato non lampeggia pi    con i tasti Up e Down sar   possibile passare alle successive impostazioni  che sono  Abbattimento a tempo o Temperatura al cuore  Durata ciclo  e Temperature di Setpoint    Premere il tasto Menu per uscire dal Menu oppure Start Stop per attivare immediatamente il ciclo di abbattimento     Nota  durante un ciclo di abbattimento    possibile accedere al Menu Set per vedere le impostazioni  ma non     possibile modificarle     Men   02   Conservazione   Se viene premuto il tasto Enter si entra nella modalit   per avviare un ciclo di sola conservazione e sul display viene  visualizzato  Conservazione   Premendo Enter si entra in modifica e il tipo di impostazione diventa lampeggiante  con i tasti Up e Down sar    possibile modificarne il valore  Negativa Positiva la pressione del tasto Enter conferma il valore impostato e il dato  non lampeggia pi    con i tasti Up e Down sara possibile passare all impostazione del Set Camera in conservazione  la  pressione del tasto Enter conferma il valore impostato e il dato non lampeggia pi 
24. e questo ciclo di abbattimento  entrare nel Menu Set e selezionare un abbattimento Hard a tempo  poi  premere il tasto Start Stop In questa modalit   operativa l abbattimento    diviso in due fasi  nella prima fase chiamata  Hard il compressore regola sul Setpoint   riferito alla sonda cella  La durata della fase Hard    la percentuale  impostata  60   del tempo totale  Durante l esecuzione di questa fase il display visualizza la temperatura di cella e il tempo  rimanente  Nella seconda fase chiamata Soft il compressore regola sul SetPoint  riferito alla sonda cella  La durata della  fase Soft    il rimanente del tempo totale    Durante l esecuzione di questa fase il display visualizza la temperatura di cella e il tempo rimanente   AI termine della fase di abbattimento si ha il passaggio automatico in conservazione     ITALIANO          20 40 80 120           Conservazione positiva e negativa   Durante la fase di conservazione positiva sul display viene visualizzato  Cell  5 Cons   il compressore regola sul Setpoint  riferito alla sonda cella  Questa fase termina premendo il tasto Start Stop e il  dispositivo entra in Stand By     Tasto avvio rapido Abbattimento positivo a temperatura Con la scheda in Stop  premere 5 secondi il Tasto Up ed  inizia immediatamente un ciclo di abbattimento positivo standard a temperatura  Il compressore regola sul SetPoint  impostato  riferito alla sonda cella  La durata normalmente ammessa per tale fase    quella massima impostata tramite  ed  
25. ella e si attivano il buzzer e il rel   allarme e sul display  lampeggia la scritta di errore  ALL Sonda Cella   Un ciclo in fase di abbattimento viene interrotto immediatamente commutando il dispositivo in Stand By e  impedendo un nuovo Start  invece durante la fase di conservazione il compressore viene attivato ciclicamente con  un Duty Cycle    Il buzzer suona per 1 minuto  ma pu   essere tacitato premendo il tasto Enter  al termine del guasto l allarme rientra  automaticamente e il rel   allarme si disattiva     ITALIANO  lt          20 40 80 120           Allarme Alta Temperatura   Durante la fase di conservazione positiva  negativa   se la temperatura rimane superiore al valore di soglia d allarme   per un tempo superiore a 30 minuti  ed    scaduto il ritardo dall inizio della fase di conservazione o dalla fine di uno  sbrinamento  si attiva un Allarme di Alta Temperatura  Sul display lampeggia la scritta di allarme  Alta Temp Cella  L allarme viene memorizzato  si attivano il buzzer e il rel   allarme  Il buzzer suona per 1 minuto  ma pu   essere tacitato  premendo il tasto Enter e l allarme rientra automaticamente quando la temperatura scende sotto il limite     Allarme Bassa Temperatura   Durante la fase di conservazione positiva  negativa   se la temperatura rimane inferiore al valore  per un tempo  superiore a 30 minuti          scaduto il ritardo dall inizio della fase di conservazione o dalla fine di uno sbrinamento  si  attiva un Allarme di Bassa Temperatura  Su
26. g   Leistung kg     90    18  C    330 480       Potenza frigorifera W  Refrigerating power W  Puissance frigorifique W 23 3  Gefrierleistung W      C  54 4   C    27980 34800       Potenza max assorbita kw  Max absorption kw  Absorption max kw  Max Energieverbrauch kw    19 4 29 1       Potenza nominale compressore HP  Nominal compressor power Hp  Puissance nominale compresseur Hp  Kompressorsnominalleistung HP    Tensione alimentazione  Voltage   Tension d alimentation  Spannung    20 30    400N 3 50 400N 3 50       Temperatura ambiente max   C   Classe  Room temperature max   C  Class  Temp  rature ambiance max   C  Classe  Raumtemperatur max        Klasse    Peso cella   unit   condensatrice  Cold room   condensing unit weight  Poids chambre froide   unit   condensatrice     43  C T  43  C T    1000 475 1120 556    Kiihlzellegewicht Kondensationseinheitsgewicht       Fluido refrigerante  Cooling gas   Gaz r  frig  rant  K  ltemittel    R404 A R404 A           20 40 80 120    ENGLISH       COLLEGAMENTI                                                                                                                                                                                                                                                                         VE UNITA    CONDENSATRICE  Be Q CONDENSATING UNIT  RP   gt  CONNECTION  PRB PRB PRB  1 3 2 3 3 818099    F  N i N CH SH y 230  50 60 Hz   20 19 18 17 16 1510  9  8  7 61 5  4  3 aleje 1    2 Il I 81 80 p9  F  N  0  
27. i entra nella modalit   di memorizzazione di un programma di abbattimento  precedentemente impostato  Sul display compare il numero del programma con l indicazione se il programma    gi    stato memorizzato oppure    libero  Tramite i tasti Up e Down si scorrono tutti i programmi da 1 a 20  per salvare il  programma al numero desiderato premere Enter  Con il tasto Menu si esce senza salvare il programma     Men   08   Lista allarmi   Se viene premuto il tasto Enter di conferma  si entra nella modalit   di visualizzazione allarmi  Possono venire registrati  fino a 30 allarmi con le relative informazioni La memoria    circolare e al raggiungimento di 30 allarmi  il nuovo allarme  cancella il pi   vecchio  Se non ci sono allarmi registrati sul display viene visualizzato Se ci sono degli allarmi registrati   sul display viene visualizzato l orario di inizio dell ultimo allarme avvenuto con il numero progressivo di allarme da  A01 ad A30  Premendo il tasto Enter vengono indicate ulteriori informazioni relative all   allarme  la temperatura di  massima o di minima  la durata  chiamare il SERVICE  l orario di fine allarme se l allarme    terminato  oppure indica che     ancora in corso gli altri allarmi memorizzati possono essere selezionati con i tasti Up e Down    Premere il tasto Menu per tornare al Menu Principale     Sonda Cella   In Stand By sul display viene visualizzato il valore della temperatura rilevata dalla sonda    Un guasto della sonda provoca un Allarme della Sonda C
28. ich the present declaration refers  complies with the following european directives    auquel cette d  claration se rapporte  est conforme aux dispositions europ  ennes suivantes    auf das sich diese Erkl  rung bezieht  den Bestimmung folgende europ  ische Richtlinien entsprechen      Macchine  2006 42 CE    Bassa tensione  2006 95 CEE e sucessive modificazioni    Compatibilit   elettromagnetica  2004 108 CEE e sucessive modificazioni    Materiali ed oggetti destinati a venire in contatto con i prodotti alimentari  89 109 CEE   Direttiva 97 23 CE   PED   Pressure Equipment Directive  apparecchi in classe 1     Machines  2006 42 CE    Low voltage  2006 95 EEC and subsequent modifications    Electromagnetic Compatibility  2004 108 EEC and subsequent modifications   Materials and objects designed to come into contact with foodstuff  89 109 EEC   Directive 97 23 EC   PED   Pressure Equipment Directive  appliances in class 1     Machines  2006 42 CE    Basse Tensions  2006 95 CEE et modifications successives    Compatibilit   Electromagn  tique  2004 108 CEE et modifications successives    Mat  riels et objets destin  s    entrer en contact avec des produits alimentaires  89 109 CEE   Directive 97 23 CE   PED   Pressure Equipment Directive  appareils en class 1     Maschinen  2006 42 CE    Niaderspannung  2006 95 EG und nachfolgende   nderungen    Elektromagnetische Vertr  glichkeit  2004 108 EG und nachfolgende   nderungen    Zum Umgang mit Nahrungsmitteln bestimmte Materialien 
29. it the Menu  or the Start Stop key to immediately start a storage cycle     Menu 03  Stored program  Enter the program selection mode by pushing the Enter key  Programs are divided into 2 categories  programs  stored by the user  non modifiable preset programs The display shows     User programs   Enter the User program selection  1 20  by pushing the Enter key The display shows the program number and the  type of cycle stored  Other programs can be selected with the Up and Down keys  Push the Menu key to exit the  Menu without selecting any program  or push the Start Stop key to activate the selected cycle immediately    By pushing the Enter key  the program is selected  and the device sets in Stand By     Preset Programs   Enter the Preset Programs selection  21 29  by pushing the Enter key The display shows the program number with  itsname The other programs can be selected with the Up and Down keys    The preset programs are the following                                                        Prog   Program name Chilling                    setstorage Duration  Freezing Temperature chamber   21 Meat chilling Chilling Temperature Yes  2  C 120 min   22 Creams chilling Chilling Time No  2  C 90 min   23 Pies chilling Chilling Time No  2  C 90 min   24 Preparations chilling Chilling Time No  2  C 90 min   25 Fish products chilling Chilling Time Yes  2  C 90 min   26 Poultry chilling Chilling Time Yes  2 90 min   27 Vegetables chilling Chilling Time No  2  C 90 min   28 Temp B
30. l display lampeggia la scritta di allarme  Bassa Temp Cella   L allarme viene memorizzato  si attivano il buzzer e il rel   allarme  Il buzzer suona per 1 minuto  ma pu   essere tacitato  premendo il tasto Enter e l allarme rientra automaticamente quando la temperatura sale sopra il limite     Allarme Black Out   Se manca l alimentazione alla scheda durante la fase di conservazione positiva  negativa      al rientro la temperatura     superiore al valore programmato  si attiva un Allarme di Black Out per mancanza di alimentazione    Sul display lampeggia la scritta di allarme  ALL BlackOut   Viene memorizzato l orario di quando    mancata l alimentazione e l orario del ritorno dell   alimentazione  si attivano  il buzzer e il rel   allarme  Il buzzer suona per 1 minuto  ma pu   essere tacitato premendo il tasto Enter e l allarme  scompare con una successiva pressione del tasto Enter     Sonda Evaporatore   La sonda permette di terminare un defrost e di attivare le Ventole Evaporatore  Un guasto della sonda provoca un  Allarme guasto della Sonda Evaporatore e si attivano il buzzer e il rel   allarme    Sul display lampeggia la scritta di allarme  ALL Sonda Evap   Gli sbrinamenti terminano a tempo e l attivazione delle Ventole Evaporatore avviene indipendentemente dalla  sonda evaporatore  Il buzzer suona per 1 minuto  ma pu   essere tacitato premendo il tasto Enter  l allarme rientra  automaticamente al termine del guasto e il rel   allarme si disattiva     Sonda Spillone   La
31. la funzione sterilizzatrice l abbattitore deve essere vuoto in stand by con la porta chiusa     Se viene premuto il tasto Enter si accede alla richiesta start sterilizzazione    Premendo il tasto Enter nuovamente si esce dal menu e la sterilizzazione non viene attivata  Mentre premendo il  tasto Up si attiva un ciclo di sterilizzazione della durata di 20 minuti    Premendo il tasto Start Stop la sterilizzazione viene interrotta prima del termine    Ogni apertura della porta termina anzitempo il ciclo di sterilizzazione     ITALIANO          20 40 80 120           Nota  Avviene per mezzo di lampade speciali    raggi UV che eliminano i batteri presenti sulle superfici e nell aria  dell abbattitore  quindi importantissima per la pulizia del vano interno  per evitare l innalzamento della carica batterica  nelle condense residue  sviluppate nei periodi di sosta  Pu   essere utilizzata anche per sterilizzare gli utensili da cucina   NON deve essere utilizzata per sterilizzare il prodotto da abbattere o congelare     Caratteristiche costruttive   Celle di abbattimento congelamento rapido   costruzione a pannelli   acciaio inox AISI 304   interno con spigoli arrotondati   isolamento in poliuretano           inserimento carrelli porta teglie GN1 1   GN2 1   BN 60x40   BN 60x80 refrigerazione ventilata con evaporatori  e ventilatori facilmente ispezionabili per pulizia e manutenzione   predisposizione per il collegamento ad unit    condensatrici ad aria    ad acqua    misurazione della
32. ling freezing   The duration of the cycle is the planned one  and it is expressed in minutes  Modify this value if necessary  then push  the Start Stop key       this mode of operation  the compressor adjusts itself on the planned SetPoint  referred to the  chamber probe  This chilling freezing phase ends when the set time elapses  During the execution of this phase the  display shows the chamber temperature and the remaining time  At the end of the chilling freezing phase  the storage  phase takes place automatically     Temperature based Hard chilling freezing   To activate this cycle  enter the Menu Set and select a temperature based Hard cycle  then push the Start Stop  key  In this mode of operation  the chilling freezing cycle is divided into two phases  in the first phase  called Hard   the compressor adjusts itself on the Hard Setpoint  referred to the chamber probe  this Hard phased ends when the  core probe temperature reaches the set value  During the execution of this phase the display shows the chamber  temperature and the core probe temperature    In the second phase  called Soft  the compressor adjusts itself on the Setpoint  referred to the chamber probe  The  normally acknowledged duration for the Hard and Soft chilling freezing phase is expressed in minutes  The Soft phase  ends when the core probe temperature reaches the value set by the parameter  During the execution of this phase   the display shows the chamber temperature and the core probe temperature 
33. nche un ciclo di sbrinamento manuale e o automatico    Se la configurazione scelta lo permette    possibile collegare un terminale di stampa per la stampa on line dei valori  di temperatura e degli allarmi     TASTO ON OFF        Premendo il tasto ON OFF per 5 sec  il controllore si spegne e sul display compare la scritta OFF con il cursore  lampegginate    Premendo successivamente il tasto ON OFF il controllore si riaccende e va in Stand by     TASTO ENTER 5    Permette di accedere ad un men   o selezionare un parametro    TASTO MENU  5    Permette di accedere al men   principale o di ritornare al men   precedente    TASTI Up e Down  A  GA    Permettono di scorrere i vari men   o di variare i valori dei parametri    TASTO Start Stop         Permette di iniziare un ciclo di abbattimento o di interromperlo     ITALIANO  lt          20 40 80 120           Cicli di abbattimento   Il compressore rimane disattivato finch   la temperatura della Cella    superiore alla temperatura di 90  C    La ventola evaporatore rimane disattivata finch   la temperatura della Cella    superiore alla temperatura 70  C   Si considera iniziato un abbattimento solo quando la Sonda Spillone rileva una temperatura inferiore a 70  C      Abbattimento Positivo o Negativo a TEMPERATURA   Per attivare questo ciclo di abbattimento  entrare nel Menu Set e selezionare un abbattimento positivo negativo a  temperatura  poi premere il tasto Start Stop    In questa modalit   operativa il compressore regola sul Se
34. splay compaiono le impostazioni del ciclo  Con i tasti Up e Down    possibile scorrere ulteriori informazioni come  il SetPoint della cella in abbattimento  ed il SetPoint cella in conservazione il valore della Sonda Spillone     possibile  scorrere ulteriori informazioni il tempo massimo consentito nella fase Hard e Soft il SetPoint cella in abbattimento  Hard e Soft  Premendo il tasto Enter si esce dal menu di visualizzazione delle impostazioni    il dispositivo ritorna nelle  condizioni precedenti    Nota  Le impostazioni del ciclo di abbattimento non possono essere modificate da questo menu     ITALIANO  lt          20 40 80 120           Descrizione Menu  Dalla finestra principale premere il tasto Menu e selezionare il men   desiderato con i tasti Up    Down  Menu 01 Set Menu di impostazione del ciclo di abbattimento    Menu 02 Conservazione Menu di impostazione di un ciclo di sola conservazione    Menu 03 Programmi Menu di selezione di un programma memorizzato  Menu 04 Sbrinamento Menu di attivazione di uno sbrinamento   Menu 05 Impostazioni Menu di impostazione del dispositivo   Menu 06 Set Orologio Menu di impostazione dell   orologio    Menu 07 Memorizzazione Menu di memorizzazione di un programma impostato  Menu 08 Allarmi Menu di visualizzazione degli allarmi memorizzati   Menu 09 Stampa Menu di stampa dei cicli memorizzati   Menu 10 Ingressi Uscite Menu di visualizzazione dello stato degli ingressi e uscite  Menu 11 Sterilizzazione Menu di attivazione di un ciclo 
35. tPoint impostato  riferito alla sonda cella  La durata  normalmente ammessa per tale fase    quella impostata ed    espressa in minuti Questa fase operativa termina quando  la temperatura dello spillone raggiunge il valore impostato  Durante l esecuzione di questa fase il display visualizza la  temperatura della cella e dello spillone  La fase di abbattimento termina quando la temperatura rilevata dalla sonda  a spillone raggiunge il set impostato e si ha il passaggio automatico in conservazione  Se l abbattimento non si     concluso entro il tempo fissato l operazione di abbattimento continua  ma sul display compare la scritta TimeOut  lampeggiante  premendo il tasto Up si vede il tempo trascorso dall inizio dell   abbattimento    Dopo l abbattimento la fase di conservazione avviene regolarmente     Abbattimento Positivo o Negativo a TEMPO   Per attivare questo ciclo di abbattimento  entrare nel Menu Set e selezionare un abbattimento positivo negativo a  tempo  il tempo di durata dell   abbattimento    quello impostato         espresso in minuti  modificare eventualmente  tale valore  poi premere il tasto Start Stop In questa modalit   operativa il compressore regola sul SetPoint impostato   riferito alla sonda cella  Questa fase di abbattimento termina allo scadere del tempo impostato in fase di settaggio   Durante l esecuzione di questa fase il display visualizza la temperatura della cella    il tempo rimanente    AI termine della fase di abbattimento si ha il passaggio au
36. tomatico in conservazione     Abbattimento Hard a temperatura   Per attivare questo ciclo di abbattimento  entrare nel Menu Set e selezionare un abbattimento Hard a temperatura   poi premere il tasto Start Stop  In questa modalit   operativa l abbattimento    diviso in due fasi  nella prima fase  chiamata Hard il compressore regola sul Setpoint Hard  riferito alla sonda cella  questa fase Hard termina quando la  temperatura dello spillone raggiunge il valore impostato  Durante l esecuzione di questa fase il display visualizza la  temperatura della cella e dello spillone    Nella seconda fase chiamata Soft il compressore regola sul Setpoint  riferito alla sonda cella  La durata normalmente  ammessa per la fase di abbattimento Hard e Soft    espressa in minuti  Questa fase Soft termina quando la temperatura  dello spillone raggiunge il valore impostato tramite il parametro  Durante l esecuzione di questa fase il display  visualizza la temperatura della cella e dello spillone    La fase di abbattimento termina quando la temperatura rilevata dalla sonda a spillone raggiunge il set impostato e si  ha il passaggio automatico in conservazione  Se l abbattimento non si    concluso entro il tempo fissato l operazione  di abbattimento continua  ma sul display compare la scritta TimeOut lampeggiante  premendo il tasto Up si vede il  tempo trascorso dall inizio dell abbattimento  Dopo l abbattimento la fase di conservazione avviene regolarmente     Abbattimento Hard a tempo   Per attivar
37. und Gegenst  nde  89 109 EG   Richtlinie 97 23 EG   PED   Pressure Equipment Directive  Ger  te in Klasse 1    La persona autorizzata a costituire il fascicolo tecnico    Paolo Guidetti  legale rappresentante della ditta  EVERLASTING S R L  S S  CISA KM 161   46029 SUZZARA  MN      ITALIA  sede presso la quale    anche custodito     The person authorized to constitute the technical file is Paolo Guidetti  legal representative of the Company  EVERLASTING S R L  S S  CISA KM 161   46029 SUZZARA  MN      ITALY  where the file is kept     La personne autoris  e    constituer le dossier technique est Paolo Guidetti  repr  sentant l  gal de la soci  t    EVERLASTING S R L  S S  CISA      161   46029 SUZZARA            ITALIE  ou le dossier est conserve     Die Person die berechtigt ist die technische Unterlagen zusammenzustellen ist Paolo Guidetti  gesetzlicher Vertreter der Firma  EVERLASTING S R L  S S  CISA KM 161   46029 SUZZARA  MN      ITALIEN  wo die Datei gehalten wird     SELE IA          N  E WEE      A soa                    le    ITALIANO          20 40 80 120                                   ABF 20P ABF 40 P ABF 80 P ABF 120 P    Door OFern    H    Stant stop       DESCRIZIONE GENERALE   La scheda fornisce un controllo per Abbattitori Surgelatori garantendo cicli di Abbattimento Surgelazione con  controllo sulla temperatura al cuore del prodotto e semplici cicli a tempo  Ogni ciclo di Abbattimento Surgelazione     seguito da un ciclo di conservazione  E  disponibile a
38. with core probe  a test is performed to check whether the core probe  is correctly inserted in the product  The probe test is organised on two levels  the fist is called fast or threshold  the  second is called slow or differential     Threshold test  During the fast test 5 comparisons are performed between the chamber temperature and the core probe temperature   If in at least 3 of the five tests the detections respect the following relation     IT  T 15        probe chamber    the probe is considered as inserted in the product to be chilled or frozen  In this case  the next phase of the test  is not executed  The duration of this phase is of around 50 seconds  since each test is performed at intervals of 10  seconds  this type of check should theoretically solve the majority of occurrences  since the differential test is only to  be executed when the product has the same temperature as the chamber  Performing more than one check allows to  have a reliable and versatile test  which does not bind the user to a strict operating procedure     Differential test  The differential test is based upon the fact that  by cooling the chamber  its temperature decreases faster than the  temperature inside the product because of the thermal inertia of the latter  This situation is summarized mathematically    by the following relation  In other words  the test verifies that the At between the inside and the outside of the  product rises     At    current previous    Dtl gt 1  C    The dur
    