Home

Detergent Pumps

image

Contents

1. Tubing Code Sekobri 9900090121 9900090098 9900090096 S een 9900090068 9900090067 Norprene i secco eo LL ia roi iii ii dkz i i I _ _____ _ _i__i_i_r r___ _ 9900090242
2. Detergent Pumps 7 A Dosing pump with conductivity probe control Hole for probe connection 22 5 mm 7 8 Power supply 230 Vac Consumption 3 5 W PA 6 Santoprene tubing 0 1 PA 9 Santoprene tubing 0 1 9 D E Fixed flow rate pump Power supply 230 Vac Consumption 3 5 W PE 1 5 Santoprene tubing 0 1 1 PE 3 Santoprene tubing 0 1 3 D Adjustable flow rate dosing pump with speed control Power supply 230 Vac Consumption 3 5 W PR 4 Santoprene tubing 0 1 PR 7 Santoprene tubing 0 1 y S a a n S 2 Q 3 S S gt het 3 D S x S Q 5 gt S D Q J and rinse solenoid valves Two setting trimmer enable detergent First Fill and Top Up Power supply 230 Vac Consumption 3 5 W First Fill time 5 to 220 sec Top Up time 1 to 20 sec PS 3 Santoprene tubing 0 1 3 PS 10 Santoprene tubing 0 1 10 Fixed flow rate dosing pump with timer control Models powered via First Fill time 18 to 180 sec Top Up time 2 to 15 sec PRT 6 Santoprene tubino 0 1 6 PRT 9 Santoprene tubino 0 1 9 Fig 1 Fig 2 Regolazione Regulation POMPA DOSATRICE PERISTALTICA A VELOCITA VARIABILE VARIABLE SPEED PERISTALTIC DOSING PUMP biadesivo adhesive tape LBAAAS MANUALE DI USO E MANUTENZIONE Pompa peristaltica a dosag
3. gio predisponibile mediante la regolazione della velocit di funzionamento Altezza di aspirazione 1 5 m AVVERTENZE In fase di installazione della pompa leggere l etichetta e verificare che e il tubo membrana sia di materiale compatibile con MAINTENANCE AND INSTRUCTIONS MANUAL Variable capacity peristaltic pump regulated through speed control Max suction hight 1 5 m NOTICE When installing the pump read the label and verify the following tubing material is compatible with the liquid Fig 3 Fig 4 il liquido che deve essere dosato the power supply available is identical to the la tensione di alimentazione sia corrispondente a indicated one lai quella indicata pressure at the injection point is lower or equal direzione di i la pressione in corrispondenza del punto di to the pump nominal pressure montaggio iniezione sia inferiore o uguale a quella nominale suction tubing is inserted in the liquid mounting i della pompa container fitted to the suction connection of direction il tubo di aspirazione sia inserito all interno del the pump represented on the lid with A and p serbatoio del prodotto sia connesso al raccordo di tightened with the proper nut see fig 1 vA aspirazione della pompa segnato sul coperchio delivery tubing is fitted to the delivery va con A e serrato con l apposita ghiera v fig 1 connection of the pump represented on the lid il tubo di mandata sia connesso al raccordo di with V t
4. hear the click Tubing Characteristics SEKO Characteristics Limitations Tubing suitable for a wide range of applications supplied as standard in all PBR PBM PE PG and PP Pumps Available in a special versione suitable for food application NOP Guna einer ON ens Tubing suitable for a wide range of applications where may be supplied with all range Not recommended with strong acids or alkaline solution of pumps Available in a special versione suitable for food application Swells up in many organic solutions Tubing with an uncomparable flexibility that assure the constant dosing after ours of i Not suitable for strong acids black pigments may leach out operation also Suitable for Alkaline products Tubing suitable for applications where are used very aggressive acids and solvents Limited lifetime High quality for medical laboratory and research use Homogeneous structure tubing More hard than the other tubing may affect the life of the for a better chemical resistance Suitable for food and medical applications gearbox Norprene Same as Santoprene is a standard tubing for the PSG and PSH models Suitable for Additives and black pigments may leach out Alkaline chemicals l l at l l Become hard and may affect motor life with some chemical Tygon R 1000 Tubing with a strong chemical compatibility but low mechanical life whit which ahs a good chemical compatibility Norprene AND Tygon R 1000 are a Saint Gobain Co Reg TM
5. ig 2 e nel caso di fissaggio su pareti con piastrelle o con finitura superficiale a basso attrito fare uso del biadesivo fornito con la pompa togliere uno dei due fogli protettivi dal biadesivo attaccare il biadesivo alla staffa togliere il secondo foglio protettivo dal biadesivo e procedere al fissaggio della staffa con la vite appoggiare la parte posteriore della pompa al di sopra della staffa in modo da far scivolare la staffa nel canale di invito ricavato sul coperchio posteriore sino all incastro Montaggio con fissaggio del coperchio e Smontare la pompa svitando le viti di fissaggio sulla scatola sollevare verso l alto il morsetto della tensione per staccarlo dal circuito 1 fori per il fissaggio sono sul coperchio posteriore della pompa far saltare le protezioni plastiche dai fori destinati al fissaggio mediante un punteruolo o un giravite come dima di foratura si pu utilizzare il coperchio stesso fissare il coperchio mediante la vite in dotazione o mediante viti 4 mm connettere nuovamente il morsetto volante al circuito e montare la parte anteriore della pompa mediante le viti di fissaggio per il cablaggio dei cavi si veda la fig 3 Montaggio filtro di aspirazione e Inserire l estremit del tubo di aspirazione nel peso metallico in modo che il tubo fuoriesca dalla parte svasata del peso stesso infilare fino in fondo il portafiltro nella stessa estremit del tubo serrare il tubo avvicinando con u
6. ightened with the proper nut and Livello mandata della pompa segnato sul coperchio con fitted to the tank injection connection Level V serrato con l apposita ghiera e sia inserito nel the protection lid of the liquid end is properly E raccordo di entrata in vasca fitted in its seat Vac il coperchio di protezione del gruppo idraulico sia the pump is connected to an electric system correttamente incastrato nella sua sede which has an all poles disconnection device PR 18 18 It hr with Santoprene tubing Cod 136131 R4 96 PERPR_IE la pompa sia connessa alla rete in modo che sia presente un dispositivo di disinserzione onnipolare con distanza di apertura dei contatti di almeno 3 mm IL MANCATO RISPETTO DI UNA DELLE PRESCRIZIONI QUI CONTENUTE PU PROVOCARE DANNI ALLE PERSONE F O IL NON CORRETTO FUNZIONAMENTO O DANNEGGIAMENTO DEGLI APPARECCHI YUY ATTENZIONE UUU Prima di effettuare qualunque intervento sulla pompa disconnettere la tensione di alimentazione with open state distance between contacts of at least 3 mm IF ANY OF THE INSTRUCTIONS HERE CONTAINED IS NOT RESPECTED THERE CAN BE DAMAGE TO PERSONS AND OR INCORRECT WORKING OR DAMAGE TO THE APPARATUS YUY IMPORTANT UUW Before carrying out any operation on the pump disconnect the power supply ISTRUZIONI DI MONTAGGIO Montaggio con staffa in dotazione e Fissare la staffa metallica mediante la vite in dotazione nella maniera indicata in f
7. na rotazione il peso al portafiltro fino a battuta La fig 4 illustra la sequenza di montaggio dei pezzi componenti il filtro di aspirazione si consiglia di usare sempre il filtro di fondo in aspirazione di accertarsi che arrivi sul fondo del serbatoio e di pulirlo periodicamente da eventuali residui di prodotto essiccato sporcizia accumulata Regolazione della portata e Per impostare il valore di portata desiderato estrarre con un giravite 5x20 il tappo di protezione a destra della spia di funzionamento Cod 136131 R4 96 INSTALLATION INSTRUCTIONS Installation with the provided bracket e Fix the metal bracket with the provided screw see fig 2 e in case of tiled or low friction walls use the supplied adhesive tape as follow peel off one of the two protective foils from the tape stick the tape to the bracket peel off the second protective foil and proceed to fix the bracket with the provided screw fix the pump on the bracket making tongues on the back of the pump slide in the bracket Installation with the back cover e Open the pump unscrewing the fixing screws on the box detach the power supply connection from the circuit holes for mounting are on the back cover of the pump break the plastic protections from the holes with an awl or screwdriver to trace the drilling template the back cover can be used fix the back cover with the provided screw or with 4 mm screws reattach the power supply connection
8. ntaggio posizionare il portarullini con i due rullini in posizione orizzontale inserire a fondo il raccordo posto a sinistra della pompa con la parte curva in basso premere il tubo nella sua sede seguendone man mano il percorso ruotando manualmente il portarullini in senso orario sino ad inserire a fondo anche il raccordo posto a destra della pompa inserire nuovamente il coperchio di protezione a partire dal bordo superiore posizionandolo con il bordo di incastro verso la pompa e premendo leggermente sui lati sino a sentire lo scatto di chiusura Tubing substitution Disconnect the pump from the power supply take off the transparent lid on the hydraulic group to dismantle the tube turn the roll holder so that the rollers are on a vertical line remove from its seat the connection on the left of the pump alternatively pull the tube out of its seat and manually rotate the roll holder clockwise until it is possible to extract the right hand side connection from its seat to mount the tube turn the roll holder so that the rollers are on a horizontal line insert the connection in its seat on the left of the pump with the curved side towards the floor alternatively push the tube into its seat and manually rotate the roll holder clockwise until it is possible to insert the right hand side connection into its seat insert the protection lid starting from the top with the shear facing the pump and pushing slightly on the sides so to
9. to the circuit and mount the front part of the pump with the fixing screws for the wiring see fig 3 Suction filter installation e Insert the end of the tubing in the metal wieght so that it exits from the flared part insert the filter container in the same end of the tubing tighten the tubing screwing the weight until it sits on the filter container Fig 4 shows the mounting steps to follow to install the suction filter It is strongly recommended to use the suction filter in all situations to assure that it reach the bottom of the tank and to clean it periodically to avoid dry residual of product or accumulation of dirt Capacity regulation e To modify the capacity take out the protection tap on the right of the operation led with a screw driver 5 x 20 e to reduce capacity turn the trimmer counter clockwise PERPR_IE per diminuire la velocita di rotazione ruotare in senso antiorario Sostituzione tubo Togliere la alimentazione alla pompa in maniera che non possa azionarsi il motore in maniera non voluta togliere il coperchio trasparente a scatto di protezione del gruppo idraulico per lo smontaggio posizionare il portarullini con 1 due rullini in posizione verticale rimuovere dalla sua sede il raccordoposto a sinistra della pompa tirando il tubo verso l alto seguendone il percorso ruotando manualmente il portarullini in senso orario sino ad estrarre anche il raccordo posto a destra della pompa per il mo

Download Pdf Manuals

image

Related Search

Related Contents

Rexel Gemini Stapler Black    LED SQUARE BASE LIGHT  WWW.BEGLEC.COM Operation Manual Mode d'emploi  Montage- und Betriebsanleitung Operation and Assembly Instructions    Panas。ni閤  Original Instructions - Evolution Power Tools  Les inégalités cantonales de santé en Auvergne  Fresh 'n Rebel 2NA500BL  

Copyright © All rights reserved.