Home

uso e manutenzione - dr drives ql0233

image

Contents

1. Lubrication Ball bearing motors are adequately lubricated at the factory motors with re greasing provisions should be re lubricated after 5000 hours running The lubricant is li base Il Motors stored over two years are recommended to check the lubrication and re grease it if necessary Ill Centre height 63 160 motors install shielded bearings and permanently lubricated Motors with centre height 180 and above use open bearings it is necessary to re grease at regular intervals If the motor is equipped with grease fittings remove the drain plug and use 3 to 4 strokes on it Operate the motor for 20 minutes before replacing drain plug QL0233 2013 REV 0
2. triangolo i Motori possono essere collegati direttamente al cavo di alimentazione Non consentito cambiare di posto la morsettiera Il filo o cavo in uscita dal motore pu essere collegato direttamente al cavo di alimentazione Il giunto di collegamento deve essere sigillato con materiale isolante IV Controllare il cablaggio e verificare che sia corretto Tutto il collegamento deve essere solido interruttori e avviamento sensibili II contattore deve essere collegato bene V Controllare la rotazione del motore Quando le sequenze di fase dell alimentazione ed i segni di collegamento del motore corrispondono l albero gira in senso orario guardando dalla sua estremit Modificare le sequenze di fase per cambiare la direzione di rotazione VI motori possono utilizzare un accoppiamento ingranaggio o cinghia per collegarsi alle attrezzature di carico i motori a 2 poli superiori a 4kW e a 4 poli superiori a 30 kw non sono adatti per il collegamento a cinghia Messa a terra Il motore deve essere messo a terra in conformit alle normative locali Funzionamento I Quando il motore collegato al carico per il corretto senso di rotazione e avviato dovrebbe mettersi in moto velocemente e senza intoppi in caso contrario arrestare immediatamente il motore ed esaminare il caso Potrebbe trattarsi di bassa tensione oppure il motore collegato in modo non corretto il carico eccessivo ecc Il Si raccomanda di controllare la corrente del mo
3. MOTORI ASINCRONI TRIFASE CON CASSA IN GHISA ISTRUZIONI DI INSTALLAZIONE E MANUTENZIONE MOTOVARIO HEART OF MOTION motori sono utilizzati per azionare diverse macchine che non presentano esigenze particolari Soddisfano la norma EN600341 1 L installazione il funzionamento e la manutenzione devono essere eseguiti da personale appositamente qualificato Si prega di seguire le seguenti istruzioni per la sicurezza personale e il corretto funzionamento del motore Controllo prima del funzionamento Verificare i dati della targhetta per accertarsi di avere scelto il modello di motore giusto ll Ispezionare il motore per eventuali danni a parti della struttura o parti di fissaggio allentate L albero deve essere ruotato a mano senza alcun sfregamento meccanico o altri rumori udibili III Prima di utilizzare un motore nuovo o che sia stato conservato per lungo tempo controllare l isolamento degli avvolgimenti al telaio con un megaohmmetro a 500v Il valore deve essere superiore a 0 38MQ OPPURE asciugare accuratamente il motore Installazione I motori sono adatti per l uso in luoghi esposti a umidit sporcizia alla maggior parte delle condizioni esterne e zone con atmosfere corrosive La temperatura ambiente compresa tra 15 e 40 C Il Controllare l apparecchio nei motori dotati di protezione da cortocircuito e sovraccarico termico III Collegare il motore secondo lo schema di collegamento fornito Tranne per l avviamento stella
4. e lubrificati in fabbrica i motori con disposizioni di reingrassaggio devono essere nuovamente lubrificati dopo 5000 ore di funzionamento Il lubrificante a base di litio Il Per i motori conservati per due anni si raccomanda di verificare la lubrificazione e se necessario reingrassare III Per i motori con altezza del centro da 63 a 160 installare cuscinetti schermati e lubrificati in modo permanente Per i motori con altezza del centro superiore a 180 usare cuscinetti aperti necessario reingrassare a intervalli regolari Se il motore dotato di ingrassatori rimuovere il tappo di scarico e impiegare 3 4 tempi Far funzionare il motore per 20 minuti prima di sostituire il tappo di scarico QL0233 2013 REV 0 CAST IRON HOUSING THREE PHASE INDUCTION MOTORS INSTALLATION MAINTENANCE INSTRUCTION ee SF MOTOVARIO HEART OF MOTION The motors apply to drive various machines that have no special requirements They measure up to the EN600341 1 Installation operation and maintenance should be performed by personnel qualified for the task Please follow the following instructions for personal safety and for proper motor operations Checking before operation I Check the nameplate data to confirm you have chosen the right motor model Il Inspect the motor for damage to structure parts loose to fastening parts Shaft should be turn by hand without any mechanical rubbing or other audible noises Ill Before operating a new motor o
5. r motors having been stored for long time inspect the winding insulation to the frame with 500v megger The value should be exceed 0 38MQ OR dry out motors thoroughly Installation I Motors are suitable for use in locations that expose to moisture dirt most outdoor conditions and areas with corrosive atmospheres Ambient temperature is between 15 40 C Il Control apparatus to the motors equipped with short phase protection and over load thermal protection Ill Connect the motor in accordance with furnished connection diagram Except for star delta starting motors can be connected to the power cable directly Terminal strip are not allowed to change place Lead or cable out of the motors can be connected directly to power cable Connection joint should be sealed by insulation material IV Check the wiring and verify it is correct All the connection should be firm switches and starter sensitive Contactor connected well V Check the rotation of the motor When phase sequences of power supply and the motor connection marks are correspond the shaft rotate clockwise viewing from shaft extension end Change the phase sequences to change the rotation direction VI Motors can use coupling gear or belt to connect with loading equipment 2 poles motors above 4kw and 4 poles motors above 30 kw are not suit for belt connection Grounding The motor must be grounded in accordance with local codes Operation When the motor is connected to
6. the load for proper direction of rotation and started it should start quickly and run smoothly if it is not the case immediately shut motor off investigate the case The case could be low voltage the motor is incorrectly connected or the load is excessive etc Il It is recommended that the motor current be checked after it has been operating a short time and compared with nameplate current III The motor is allowed to start twice in succession at ambient status but only once at heart status after running with rated load Any more start will be done when the motor temperature is lower than steady state temperature IV Choose the right starting method according to capacity of electric network source the motor output starting torque It is recommended that star delta or step down starting method should be used for bigger output motors Power supply and connections Motors will operate satisfactorily on line voltage within 5 of the nameplate value Il The running current cannot exceed the nameplate value or the motor will be heated even burnt III The motor should be kept clean and dry prevent water and dirt enter IV The motor should be well ventilated V The motor must be shut off when any of the following situation occurred personal shock motors fire motor strong vibration loading equipment damage bearing over heat abnormal noises peculiar smell sudden speed dropped quick temperature rise short phase fastener loose etc
7. tore dopo un breve periodo di funzionamento e di confrontarla con la corrente riportata sulla targhetta Il Il motore viene fatto partire due volte di seguito in condizioni normali ma solo una volta in condizioni di calore dopo aver girato a carico nominale Il prossimo avviamento verr effettuato quando la temperatura del motore sar inferiore a quella di regime IV Scegliere il metodo di avviamento corretto in base alla capacit della sorgente di rete elettrica alla potenza del motore e alla coppia di avviamento Si raccomanda di utilizzare il metodo di avviamento stella triangolo o a tensione ridotta per i motori con potenza superiore Alimentazione e collegamenti I motori funzionano in modo soddisfacente a una tensione di rete entro il 5 del valore della targhetta Il La corrente di di funzionamento non pu superare il valore della targhetta altrimenti il motore si riscalda o si brucia III Il motore deve essere mantenuto pulito e asciutto evitare la penetrazione di acqua e sporco IV II motore deve essere ben ventilato V Il motore deve essere spento quando si verifica una delle seguenti situazioni scossa incendio motore forte vibrazione del motore danni alle attrezzature di carico surriscaldamento dei cuscinetti rumori anomali odore particolare improvvisa riduzione della velocit rapido aumento della temperatura fase corta fissaggio allentato ecc Lubrificazione I motori su cuscinetti a sfera sono adeguatament