Contents
1. Solsonica S p A non si assume alcuna responsabilit e declina espressamente qualsiasi responsabilit per perdita danno lesione o spesa che dovessero insorgere da o in relazione a dette installazione funzionamento utilizzo e manutenzione del modulo o da errori di progettazione degli impianti ospitanti il modulo Solsonica S p A declina qualsiasi responsabilit in merito a eventuali violazioni di brevetti o di altri diritti di terzi che dovessero insorgere dall uso del modulo Solsonica S p A si riserva la facolt di apportare modifiche al prodotto alle specifiche o al presente Manuale senza preavviso Index General precautions General rules Elettrical installation Mechanical installation Maintenance Responsability limitation pag pag pag pag pag pag 10 10 11 12 15 15 ENG 10 1 General precautions Attention read carefully all instructions for installation and safety reported in this manual before starting any installation s operation electrical connection activation or maintenance of the modules If you do not observe following recommendations warranty can decays All installation s and maintenance s operation must be done by certified and qualified staff that works following in force law Contact with active parts of the module like connectors can cause burns sparks or lethal electrocutions both if the module is connected or not Contact wi
2. 14 In special cases Solsonica allows the installation of Silver Plus S610 PP on the short edge using dedicated fixing kit on support bars Front view EE 550420 224210 RN E This solution can be used only for coplanar mounting in respect the roof in climatic area where wind cannot have a force higher than 50 Kg mq For 72 cells modules and depending on the local wind and snow loads a third support bar and related clamping kit may be required Solsonica suggest to use a containment support to be connected to the main structure for anchorage of the frames of the modules in the first row e Sealed frame modules Mounting have to be done with modules on horizontal uprights positioned at fixed distances and using specific clamps See below explaining drawing Back side Installazione Sealed Frame JBOX wees Particolare installmivo morsetto finale Particolare installativo morsetto centrale Se I p Clamps can be provided by Solsonica ENG e Frameless modules For Frameless S610 FLP used on standard applications on uprights must be used specific clamps like those used for glass glass solutions In specific cases like greenhouse holder frame must be projected in a way that contact between module and frame is through appropriate rubber gaskets to avoid direct contact between glass and frame See you below a mounting example through uprights with highl
3. autorit competenti Assicurarsi che i siti d installazione siano in grado di sopportare il carico aggiuntivo dovuto ai moduli Assicurarsi che le eventuali strutture di supporto ai moduli siano state opportunamente dimensionate al carico Attenersi alle opportune procedure di sicurezza e utilizzare un idoneo equipaggiamento protettivo Si raccomanda di effettuare le operazioni di trasporto dei moduli almeno in due persone provviste di opportuni guanti anti scivolo 3 Installazione Elettrica Il modulo stato certificato in classe di protezione Il a 1000 V di isolamento a queste caratteristiche di protezione necessario rifarsi al momento dell uso dello stesso Tutte le caratteristiche elettriche e meccaniche dei moduli sono riportate sul sito di Solsonica all indirizzo www solsonica com Il numero massimo di moduli che possono essere collegati in serie deve essere tale che la massima tensione a vuoto del campo fotovoltaico deve essere inferiore alla massima tensione ammessa dal modulo 1000 V Per il calcolo fare riferimento alla formula N Max Tensione 1 25 Voc La massima sovracorrente ammessa dal modulo di 14 00 A Nel caso in cui pi stringhe di moduli siano poste in parallelo necessario prevedere dei diodi di bypass con caratteristiche adeguate al fine di eliminare potenziali sovracorrenti che possono danneggiare i moduli Il modulo equipaggiato con una scatola di giunzione che permette la connessione elettrica d
4. el modulo La scatola di giunzione equipaggiata con 3 diodi di by pass le cui caratteristiche sono riportate di seguito J Box COMPEL Schottky Rectifier IFav 18 A VRRM da 35V a 45V Top Max 175 C J Box ANSA Schottky Rectifier IF av 20 A VRRM 45V Top Max 150 C Non sono ammessi interventi all interno della scatola di giunzione La scatola di giunzione posta nella parte posteriore del modulo sulla parte frontale della scatola sono riportati i simboli della polarit positiva e negativa ai quali necessario attenersi in fase di connessione dei moduli Per un corretto accoppiamento dei connettori con la scatola di giunzione la guarnizione del connettore O ring non deve essere visibile e le clip di ritenzione devono garantire resistenza a forze di trazione Connettore femmina Connettore maschio moduli possono essere connessi tra di loro utilizzando dei connettori compatibili con quelli presenti sulla scatola di giunzione Per la connessione sulle scatole di giunzione utilizzare connettori e cavi in classe II forniti da Solsonica Nel caso di cavi elettrici non forniti da Solsonica assicurarsi che le caratteristiche tecniche minime rispettino la normativa CEI 20 91 v1 La connessione va fatta nel rispetto della normativa vigente La connessione sulla scatola di giunzione deve essere effettuata utilizzando esclusivamente la posa fissa dei cavi di cablaggio Il minimo raggio di curva
5. hat the structures are suitable for modules weight Follow safety procedures and use suitable protective equipment At least Two persons with anti skid gloves are necessary to carry the module ENG 3 Electrical installation Module is certified for safety class Il at 1000V and to this specification is necessary to refer to use it All electrical and mechanical characteristic are reported on Solsonica web site www solsonica com Maximum number of modules that can be series connected is limited by maximum Open circuit voltage of the photovoltaic plant that must be less than maximum module s voltage 1000V For calculation refer to the formula N Max Voltage 1 25 Voc Maximum overcurrent accepted by module is 14 00A In the case that several module s strings are parallel connected Bypass diodes of suitable electrical characteristic are necessary to eliminate potential overcurrent that could damage the modules Module has a junction box for electrical connection the junction box has 3 by pass diodes with following electrical characteristic J Box COMPEL Schottky Rectifier IF AV 18 A VRRM 35V to 45V Top Max 175 C J Box ANSA Schottky Rectifier IF Av 20 A VRRM 45V Top Max 150 C Manipulation inside the Junction box are not allowed The Junction box is placed on the back of the module itself on the front of the junction box are indicated the positive and negative pole to which refers to for module connectio
6. ighted distance between uprights themselves dotted line Back side JBOX 350423 9552 5 Maintenance No ordinary maintenance is required its suggested to periodically check to modules to detect damages to the glass frame or back of the module No cleaning it s required as normal rain it s enough to keep the module in proper operation Anyway cleaning of dirtiness s excess can increases the energy s production We recommend to clean the glass with water and soft cloth or sponge Do not clean with corrosive or chemically aggressive substances Check yearly mechanical and electrical connection For electrical and mechanical inspection refer to trained staff to avoid electrical shock 6 Responsibility limitation Solsonica S p a do not assume any responsibility and declines expressly any responsibility for loss damage expense related to installation working use and maintenance of the modules or due to wrong project of the photovoltaic plant Solsonica S p A declines any responsibility for patent s or third party s right violation due to the module s use Solsonica S p A can modify the product datasheet and manual without any notification REINA Solsonica S p A viale delle Scienze 5 02015 Cittaducale RI Italy Numero Verde 800 078 555 sales solsonica com aora is www solsonica com
7. meccanica del capocorda al modulo va fatta utilizzando bullone rondella e dado M4 In casi particolari Solsonica permette l ancoraggio dei moduli Silver Plus S610 PP anche sul lato corto utilizzando appositi morsetti di serraggio Front view 24410 _ 23 soa 550420 4210 a E a Questa soluzione pu essere utilizzata esclusivamente con montaggio del modulo coplanare alla copertura in zone climatiche tali che il vento non sia in grado di generare una spinta superiore a 50 Kg mq Per i moduli a 72 celle e nelle zone con particolari condizioni di carico di vento o neve si consiglia l uso di 3 barre di supporto e relative coppie di morsetti di serraggio E inoltre consigliato l uso di un supporto di contenimento da ancorare alla struttura per le cornici dei moduli in prima fila e Moduli Sealed Frame Il montaggio va effettuato posizionando il modulo su montanti orizzontali posizionati a distanza prestabilita e utilizzando dei morsetti specifici Di seguito sono riportati dei disegni esemplificativi Back side IBOX Installazione Sealed Frame x I Iii I mi Particolare installaivo morsetto fimabe Particolare installativo morsetto centrale UN ar morsetti possono essere forniti da Solsonica e Moduli Frameless Per il modello Frameless S610 FLP utilizzato per applicazioni standard su montanti si dev
8. ns For a correct connection of connectors to the Jbox the O ring must not be visible and the locking clamp must resist to traction s forces Negative pole i ENG 12 Modules can be connected using compatible connectors For connection use Class Il connectors and electrical cables supplied by Solsonica or with technical characteristics aligned with CEI 20 91 v1 Connection must obeys to in force law Connection to the Jbox must be done only with fixed cable s laying Minimum radius of curvature allowed must be higher or equal to 5 times cable s diameter Cable must be layed in order to avoid traction stess both on connections and conductor After installation cables must not be fixed to the Junction box Radius R gt 5Xcable diameter 5x 2 OK Junction box must be disconnected from any energy source during cables and connectors installation to assure suitable protection from Electrical shock and module s damages In normal operation a module can produce more current or voltage than reference values that are related to standard test conditions If you refer to Isc or Voc value for electrical dimensioning of the photovoltaic plant multiply this value by a safety factor 1 25 minimum 4 Mechanical installation WARNING don t walk on the module or leave load on the surface PV cells may break e The junction box must be in the higher side of the module when it is mounted in order t
9. o orient the breather port correctly and avoid humidity or rain penetration e Silver Plus Modules Modules must be installed on support bars using anchorage systems specific for photovoltaic installation Use mounting holes available on the module s frame or specific clamps No fixing element of the support structure must be in contact with glass unless expressly projected and approved Mounting with bolts See below the Silver Plus S610 PP drawing with mounting holes highlighted Same fixing holes are available on all Solsonica models with aluminum frame ENG Back view Sent JBOX 3S1 Sz1 351 Set For modules installation use M6 screws nuts and washers of A1 steel The torque on the clamp bolt should be 8 Nm Mounting with clamping tools Use photovoltaic modules clamping kits only following the supplier recommendations for the torque Front view 351 4225 960250 166 3613025 Installation using holes Installation using clamps For grounding of the modules it s necessary to use the ground s hole on one of the long side of the module identified by a label with ground symbol For ground electrical connection use 1x4mmq cable with yellow green sheath The electrical cable must have a cable terminal with hole suitable for M4 bolt Cable terminal must be of A1 steel Electrical connection to the module must be done using M4 bolt washer and screw nut ENG
10. ono utilizzare morsetti specifici simili a quelli utilizzati per soluzioni vetro vetro Nel caso invece si utilizzi il modulo per applicazioni specifiche quali per esempio le serre necessario che il telaio di contenimento del modulo sia realizzato in modo tale che il contatto tra modulo e telaio avvenga tramite opportune guarnizioni che impediscano il contatto diretto tra vetro e struttura Di seguito un esempio di montaggio mediante montanti con evidenziato il passo tra i montanti stessi linea tratteggiata Back side JBOX 955250 5 Manutenzione Non sono richieste operazioni ordinarie di manutenzione consigliabile tuttavia effettuare dei controlli periodici per verificare eventuali danni a vetro telaio e parte posteriore del modulo Il modulo non richiede pulizia essendo sufficiente la pioggia per mantenere un funzionamento efficace tuttavia l eliminazione di eventuali eccessi pu incrementare la produzione di energia Si raccomanda di effettuare le operazioni di pulizia del vetro con acqua e un panno soffice o una spugna Non effettuare operazioni di pulizia con materiali potenzialmente corrosivi o chimicamente aggressivi Si raccomanda di effettuare ispezioni annuali sulle connessioni meccaniche ed elettriche Nel caso si abbia necessit d ispezioni di tipo meccanico o elettrico bene rivolgersi a personale qualificato per evitare di esporsi a rischi di shock elettrici 6 Limitazione di responsabilit
11. oraggio specifici per installazioni fotovoltaiche utilizzando le asole di ancoraggio presenti sulla cornice o appositi morsetti di serraggio Nessun elemento di fissaggio alle barre di supporto deve venire in contatto diretto con il vetro se non appositamente progettato ed approvato Ancoraggio su asole di seguito viene riportato il disegno del modulo Silver Plus S610 PP dove sono evidenziate le asole di ancoraggio Le medesime sono presenti anche su tutti gli altri modelli di Solsonica provvisti di cornice in alluminio Back view JBOX 3S1 Sz1 351 Set Per il fissaggio dei moduli utilizzare viti dadi e rondelle M6 in acciaio A1 La coppia di serraggio deve essere 8 Nm Ancoraggio con morsetti di serraggio Usare solo morsetti specifici per moduli fotovoltaici seguendo le raccomandazioni del fornitore per la coppia di serraggio da utilizzare Front view 351 ars 960250 ast ders 3514235 A Aggancio con morsetti di serraggio Per la messa a terra del modulo necessario utilizzare l apposita asola presente su uno dei due lati lunghi della cornice contrassegnato dal simbolo di terra Per la connessione elettrica di terra utilizzare un cavo 1x4mmq con guaina di colore giallo verde Il cavo elettrico va intestato con un capocorda che presenta un asola tonda con foro da permettere l utilizzo di un bullone M4 Il capocorda deve essere in acciaio A1 La connessione
12. solsonica 4 IVETAITE Me KTE moduli fotovoltaici Solsonica pv modules use and maintenance manual Indice Avvertenze generali Regole generali Installazione elettrica Installazione meccanica Manutenzione Limitazione responsabilit pag 3 pag 3 pag 4 pag 5 pag 8 pag 8 1 Avvertenze generali Attenzione leggere con attenzione tutte le istruzioni per l installazione e la sicurezza riportate nel presente manuale prima di eseguire qualsiasi operazione d installazione collegamento elettrico azionamento o manutenzione del modulo La mancata osservanza delle indicazioni di seguito riportate pu costituire il decadimento dei termini di garanzia Tutte le operazioni d installazione e manutenzione devono essere eseguite da personale certificato e qualificato che operi secondo le disposizioni normative vigenti Il contatto con i componenti elettricamente attivi del modulo come i connettori pu provocare ustioni scintille o elettrocuzioni letali sia che il modulo sia collegato o scollegato Il contatto con una tensione a corrente continua di almeno 30V potenzialmente pericolosa moduli generano tensione quando sono esposti alle radiazioni solari inoltre sia la corrente elettrica sia la potenza generata aumentano proporzionalmente all intensit della luce rischi legati a shock elettrici aumentano qualora i moduli vengano connessi in serie aumentando la
13. tensione prodotta oppure in parallelo aumentando la corrente prodotta moduli sono stati sottoposti a rigidi test di qualit ed efficienza i cui parametri sono riportati nei data sheet di prodotto tutti i dati sono riferiti a condizioni standard di test L energia elettrica prodotta dai moduli pu essere influenzata dall area geografica e dalla loro esposizione clinometrica Non eseguire le operazioni d installazione in presenza di forti venti Non installare i moduli in prossimit di potenziali sorgenti infiammabili Tutte le persone non autorizzate non devono essere in prossimit della zona di Installazione Si raccomanda di maneggiare i moduli tenendo coperta l intera superficie con materiale opaco in modo da impedire alla luce di raggiungere la parte attiva del modulo celle Lavorare sempre in condizioni di asciutto ambiente moduli strumenti Non calpestare il modulo Non forare o danneggiare nessuna parte del modulo n ostruire i fori di drenaggio Non rimuovere alcuna delle parti che costituiscono il modulo assemblate dal costruttore Non lasciare i moduli privi di sostegno o di un appropriato fissaggio Non trattare con sostanze adesive tinture oli o lubrificanti nessuna parte del modulo moduli non sono adatti per essere utilizzati con sistemi che concentrino la luce solare 2 Regole Generali Prima di installare i moduli accertarsi di essere in possesso dei requisiti e le autorizzazioni richiesti dalle
14. th Voltage by continuous current of at least 30V can be dangerous Modules produce voltage when exposed to sun voltage and current increase proportionally with sun s intensity Risks related to electrical Shock may increase when the modules are connected in series with higher voltage or in parallel with higher current Modules have been put through serious quality test as reported into datasheet all data are related to standard test conditions Energy produced can be influenced by geographical area and by clinometer exposition Do not install the modules in windy days Do not install the modules near flammable material Only authorized people can get to the installation s area Handle the modules covering the surface with matt material to avoid sunlight to reach active part of the module solar cell Work always in dry condition ambient modules tolls Do not walk over the module Do not make additional holes or damage any part of the module do not close the drainage holes Do not remove any part form the module installed by the manufacturer Do not leave module without fixing Do not use adhesive painting oil or lubricant on any part of the module Modules are not suitable to be used with light concentrating system 2 General rules Before starting installation assure to have all authorization required by authorities Make sure that the installation s site can carry the additional load due to the modules Make sure t
15. tura consentito deve essere maggiore o uguale a 5 volte la misura del diametro del cavo Il cavo deve essere posizionato in modo da impedire stress da trazione sia sul conduttore che sulle connessioni cavi non devono essere fissati alla scatola di giunzione una volta terminata l installazione Raggi R 2 5x diametro del cavo 5 x OK La scatola di giunzione deve essere disconnessa da ogni sorgente di energia durante l installazione di cavi e o dei connettori per garantire una adeguata protezione contro shock da scariche elettriche e danneggiamenti al modulo In condizioni di funzionamento normale un modulo pu produrre pi corrente o tensione di quanto riportato nei dati di targa del modulo che sono stati calcolati secondo la normativa in condizioni di test standard Nel caso in cui i valori di Isc o Voc vengano utilizzati per il dimensionamento di componenti elettrici del campo fotovoltaico necessario moltiplicare questi ultimi per un fattore di sicurezza minimo pari a 1 25 4 Installazione meccanica ATTENZIONE non camminare sui moduli o porre pesi sulla superficie Le celle fotovoltaiche potrebbero rompersi e L orientamento del modulo nella struttura deve essere tale che la scatola di giunzione sia nella parte alta del modulo Questo per evitare che la condensa o la pioggia entrino nella scatola e Moduli Silver Plus moduli devono essere fissati su barre di supporto trasversali mediante sistemi di anc