Home

Scarica il catalogo

image

Contents

1. Range di potenza HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 Nome modello 1JHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH162GALH AJH180GALH AJH198GALH AJH216GALH AJH234GALH AJH252GALH AJH270GALH AJH288GALH AJH306GALH AJH324GALH AJH342GALH AJH360GALH AJH378GALH AJH396GALH AJH414GALH AJH432GALH Unit 1 AJHA72GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJHA90GALH AJHA90GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH Unit 2 AJHA72GALH AJHA90GALH AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH AJH108GALH AJH108GALH AJH108GALH AJH108GALH AJH144GALH AJH144GALH AJH144GALH AJH144GALH Unit 3 AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJHA90GALH AJH108GALH AJH126GALH AJH144GALH Livello massimo unit interne collegabili 15 16 17 21 24 27 30 32 35 39 42 45 48 50 53 57 60 63 64 64 64 Capacit unit interna collegabile kW 11 2 33 6 14 0 42 0 16 8 50 2 20 0 60 0 22 5 67 5 25 2 75 6 28 0 84 0 30 8 92 2 33 5 100 5 36 5 109 5 39 3 117 7 42 5 127 5 45 0 135 0 47 5 142 5 50 3 150 7 53 3 159 7 56 0 168 0 59 0 177 0 61 8 185 2 65 0 195 0 67 5 202 5 Alimentazione 3 fasi 4 fili 400 V 50Hz 3 fasi 4 fili 400 V 50Hz Capac
2. per dispositivo di controllo del sistema per dispositivo di controllo del sistema Lite UTY PLGXA1 L energia usata da Viene calcolata l energia ciascuna unit viene distribuita dall unit calcolata esterna a ciascuna unit interna Cani Cani Condomino A Gq Y Condomino B li k Condomino C Viene calcolato il livello di L energia usata da ciascuna elettricit per ciascun unit interna e l energia condomino distribuita dall unit esterna II livello di distribuzione per l energia vengono aggiunte percalcolare utilizzata da ciascuna unit interna la quantit totale di energia viene calcolato il consumo elettrico utilizzata da parte di ciascuna unit interna viene calcolato dai livelli totali di elettricit consumata Energia unit interna usata Condomino A Condomino B Condomino C ds Energia distribuita Xp e Il disegno sul layout del l piano pu essere importato per effettuare con facilit le impostazioni W 3 4 fili 400V 50Hz sull edificio effettivo Operazioni con un clic sull unit Bolletta Bolletta Bolletta elettricit elettricit elettricit CondominoB 2 Controllo d insieme su unit liberamente selezionate Nota Layout piano 2D Visual edificio 3D non disponibili lei io per il dispositivo di controllo sistema Lite Vista piano 062 063 Dispositivi di controllo RIEPILO
3. 166 650 154 eo N e nE JH LS E E D Ges e Terminal blocks Transmission Terminal blocks Power 1334 3 Way valve Liquid S 3 Way valve Gas Gas valve Pipe amp cable port 0000000000000 029 030 Pompa di calore Design d avanguardia e intelligente Composizione ampia da 8HP a 48HP Livello capacit unit interne collegabili fino a 150 8 10 12HP 14 16HP Caratteristiche Caratteristiche Funzionamento effettivo ad alta efficienza IICOP elevato di alta classe viene realizzato per tutte le combinazioni tramite la nostra struttura esclusiva di scambiatori di calore compressore Twin DC ad alta efficienza e tutta la tecnologia applicata Combinazione per spazi ridotti COP 5 4 37 417 4 17 402 4 04 393 3 97 4 03 404 398 4 00 395 397 404 40 400 401 3 98 399 396 397 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 42 44 46 48 HP Combinazione per alta efficienza energetica COP 5 4 37 4 37 4 08 4 23 4 22 4 15 4 12 06 402 396 393 3 94 es Combinazione 24 HP Riduzione spazio Efficienza energetica 1 COP 12 IN PIU 16 22 24 26 28 30 32 34 36 40 42 44 HP Compattezza e risparmio di spazio Per ottenere le dimensioni comp
4. e G S Test operativo e e B e e e i N Impostazione aletta per direzionamento dell aria verso l alto verso il basso e a E e e e e e Timer e Impostazione aletta per direzionamento F Controllo Termo Timer spegni f dell aria verso destra verso sinistra e e a e e hd e individuale sensore settimanale mento Display temperatura 5 automatico Impostazione gruppo E amp nella stanza E Blocco RC e e o N 5 Impostazione antigelo e e e o Impostazione modalit risparmio e e o e Sensore temperatura nell ambiente Funzione errore e e e o Sbrinamento e o e A T Vari sistemi di controllo del risparmio energetico TIMER e e e e o Giorno della settimana o e E e e e o Timer spegnimento automatico Timer settimanale con 2 programmi Blocco RC e e o e o e o e L unit interna viene automaticamente spenta quando raggiunge la fascia possibile impostare due programmi ad esempio per l inverno e l estate Priorit raffreddamento riscaldamento oraria operativa pre impostata ui PA e ii gt e e e e e e e e e La fasci ia del ti di t t ico ont t e 8 impostazioni modificabili per giorno della settimana voci di impostazione e Display indirizzo O e e e e SA Teoerel OrstHet Oen PUCO SpSuHe o uD PUO ESSEE progra accensione spegnimento temperatura modalit or
5. Dispositivo di Dispositivo di Dispositivo di controllo wireless controllo semplice controllo con filo Dispositivo di controllo con filo Pannello touch Dispositivo di controllo Dispositivo di controllo Dispositivo di controllo Sistema di controllo remoto per gruppo remoto centrale con pannello touch LITE Software 015 Efficienza energetica elevata L efficienza risulta considerevolmente migliore grazie all impiego del compressore rotativo Twin CC della tecnologia a inverter e di uno scambiatore di calore di grandi dimensioni 16 8 WZ IN PI x 27 IN PI 27 IN PI m m Modello nuovo 1 m NM Modello precedente n EERM COE Pompa di calore 10HP Pompa di calore 6HP Pompa di calore 8HP Funzione di risparmio energetico Limitazione punto impostato temperatura ambiente Gli intervalli di temperatura massima e minima possono essere limitati garantendo pertanto un ulteriore risparmio energetico e assicurando il massimo comfort per gli occupanti Funzionamento risparmio energetico Il funzionamento a risparmio energetico pu essere impostato tramite il dispositivo di controllo remoto L impostazione della temperatura viene automaticamente bilanciata per un certo periodo di tempo C 30 28 26 mM we 24 bee p PAIA 22 i 20 Imposta temp v Impostazione temperatura di riscaldamento MAX 4 C Temperatura controllo gt
6. Scambiatore di calore Unit esterna L efficienza risulta sostanzialmente migliorata grazie al motore ad alta efficacia dotato di un sofisticato sistema di controllo della trasmissione Inoltre il motore a ventola Scambiatore di calore sottoraffreddamento con l impiego di una struttura a doppio tubo dalla forma del nuovo scambiatore di calore a 4 lati che aumenta Porta assunzione frontale struttura di aspirazione dell aria ad angolo tagliato Nelle installazioni di unit esterne multiple l esclusiva porta di aspirazione aria frontale garantisce il miglioramento del flusso d aria nello scambiatore di calore Controllo sofisticato delle operazioni Quando vengono collegate unit multiple il carico termico viene distribuito su pi compressori L efficienza risulta migliorata da tutti i compressori a carico parziale con la distribuzione del refrigerante a tutti gli scambiatori di calori e non ad un solo compressore Sistema ad Alta Efficienza Sistema meno efficiente Livello carico compressore 039 040 Caratteristiche Flessibilit di design Lunghezza totale delle tubazioni 1 000 m Lunghezza effettiva delle tubazioni Max 165 m Lunghezza tubazioni dal primo giunto di separazione all unit interna pi lontana Max 60m Pressione statica utile di 80 Pa La ventola a diametro grande e il motore CC a 3 fasi sono stati utilizzati cos da consentire una pre
7. Per tipo a soffitto Pompa scarico condensa UTR DPB24T Per modelli a soffitto o Arresto di emergenza TY XWZXZ dis Q UTY XWZXZB ev 6 O UTY XWZXZ8 o UTY X VZXZE Blocco termostato forzato O UTY XWZXZ7 Low Noise Mode Operation UTY X VZxZ6 Priorit raffreddamento 4 UTY xwzxze riscaldamento UTY xwzxz6 O UTY XWZXZB Operazioni in modalit rumore UTv xwzxzo basso Informazioni sul consumo elettrico tramite il contatore 9 UTY XWZXZ6 Stato operativo UTv xwzxzc Q UTY XWZXZ6 Q UTY XWZXZA Q UTY XWZXZA Stato errore UTv xwzxzc Q UTY XWZXZ6 Q UTY XWZXZA Q UTY XWZXZA S Stato operazioni ventola unit 3 niens UTv xwzxzc Uscita calorifero ausiliare UTY xwzxzc 2 Calorifero base UTY X VZXZ9 1 Solo per modello con pompa di calore 2 Solo per modello con tubo Contatto asciutto O Applicazione tensione 079
8. B OWS Dispositivi di illuminazione VRF network system 2 i JI E Sistema sicurezza non incluso moo LI b Interfaccia allarme automatico 1 l adattatore USB una interfaccia di rete U10 USB di Echelon Corporation Requisiti di sistema del PC UTY ABGX Microsoft Windows Vista Home Premium 32 bit SP2 Windows Vista Business 32 bit SP2 Microsoft Windows 7 Home Premium 32 bit o 64 bit SP1 Windows 7 Professional 32 bit o 64 bit SP1 Microsoft Windows 8 32 bit o 64 bit Windows 8 Pro 32 bit o 64 bit Microsoft Windows 8 1 32 bit o 64 bit Windows 8 1 Pro 32 bit o 64 bit Lingue supportate Inglese cinese francese tedesco russo spagnolo polacco Sistema operativo CPU Intel Core M i3 2 GHz o successivo Per Windows Vista e Windows 7 32 bit 2 GB o maggiore pma Per Windows 7 64 bit Windows 8 e Windows 8 1 4 GB o maggiore HDD Spazio libero maggiore o uguale a 40 GB Display Risoluzione maggiore o uguale a 1024 x 768 Porta Ethernet per accedere a Internet utilizzando la LAN Interfaccia Porte USB Max 5 porte 1 porta USB necessaria per la chiave Wibu Max 4 porte USB sono necessarie per l interfaccia di rete Echelon U10 USB numero max di poter USB richieste dipende dalle configurazioni di sistema applicabili Software Adobe Reader 9 0 o successivo Unit ottica Unit DVD ROM Elenco imballaggio N
9. Il PC deve essere fornito su campo L interfaccia di rete U10 USB deve essere fornita su campo Contattare Echelon Corporation o i suoi rappresentanti locali per ulteriori informazioni Nome prodotto Interfaccia rete U10 USB TP FT 10 canali Numero modello 75010R Il sistema di rete VRF pu supportare Strumento di monitoraggio web UTY AMGX sistemi VRF Caratteristiche prodotto 1 10 0 unit interne eLa risoluzione dei problemi viene svolta monitorando da remoto ciascuna unit di condizionamento durante i controlli periodici sul sistema AUS eLa notifica di errore pu essere automaticamente trasmessa a varie localit utilizzando Internet Richiede una connessione Internet dedicata o la linea pubblica telefonica Una presenza di errore pu essere determinata tramite la segnalazione di allarme e tramite le informazioni sullo stato dell impianto ottenute da una localit remota dati di monitoraggio su uno schermo remoto possono essere scaricati in forma opzionale Inoltre questi dati possono essere visualizzati in modalit non in linea nel service tool eII monitoraggio sul computer non richiede l installazione di software specifici unicamente richiesto un browser web 1 richiesto l uso del sistema di posta elettronica via Internet Sistema di monitoraggio web Monitoraggio Sistema di rete VRF Unit esterna Linea di trasmissione Strumento di monitoraggio web Internet o linea pubblica del
10. 1936 Costituita come Yaou Shouten Ltd 1960 Ha inizio il business dei condizionatori d aria Ha inizio il business sul territorio giapponese 1971 Esportazioni dei condizionatori d aria in Medio Oriente 1977 Serie Massima potenza super silenzioso Creazione stabilimenti aziendali Creazione societ di vendita 004 1982 3 super serie da finestra AL AX series 1985 Vengono introdotti i multi condizionatori d aria e montati su grandi pareti 1991 Condizionatori d aria con il primo scambiatore di calore lambda al mondo Creazione stabilimento produttivo 1976 Societ di vendita in Nord America 1977 Societ di vendita in Europa Regno Unito 1225 Condizionatore d aria con il primo per potenza di diffusione al mondo Diffusore di energia Stabilimento produttivo di condizionatori d aria in Tailandia 1978 Societ di vendita in Australia Societ di vendita in Europa Germania 1980 Societ di vendita in Brasile 2001 Condizionatori d aria VRF AURSTAGE 2003 Condizionatori d aria con il primo sistema di filtraggio di auto pulizia Stabilimento produttivo di condizionatori d aria a Shanghai Cina 1997 Societ di vendita in Asia Singapore 2009 Tipo combinato VRF V ATERSTAGE Stabilimento produttivo motorizzato di condizionatori d aria in Tailandia 1998 Societ di vendita
11. Creazione di comfort europe FIDAKIS GROUP Sede Via Vouliagmenis 128 16674 Glyfada Atene Grecia tel 30 210 9696500 fax 30 210 9697625 www fgeurope gr Fujitsu General crea prodotti di alta qualit ed ecosostenibili che offrono il massimo conforto in conformit alla propria politica fondamentale la quale richiede di creare un ambiente confortevole utilizzando le tecnologie di condizionamento dell aria e la creativit alimentata e sviluppata nel corso dei tanti anni di esperienza FG ITALIA S p A Via Po 14 Localit Mellaredo 30030 Pianiga Ve Italia tel 39 041 5190312 fax 39 041 5190041 fax assistenza Tecnica 39 041 517315 info fgitalia general com www fgitalia general com PEC fgitaliaspa legalmail it f Fujitsu General Limited AANRSTAGE Jl s J IIS ALIA Im 8 A qi VA H 014 016 022 026 030 038 046 052 066 072 074 Presentazione AIRSTAGE Caratteristiche AIRSTAGE AIRSTAGE J IIS AIRSTAGE J II AIRSTAGE V II Versione recupero di calore AIRSTAGE VR II Unit interne AIRSTAGE Dispositivo di controllo Adattatore e convertitore Assistenza e manutenzione Parti opzionali per VRF 12 societ di vendita all estero e 7 societ di produzione all estero E Sede centrale ll Societ di vendita liM Societ di produzione am A mA FUJITSU GENERAL AMERICA INC FUJITSU GENERAL
12. Dispositivo Dispositivo Dispositivo Dispositivo Dispositivo Dispositivo Dispositivo DISPOSTO Dispositivo U controllo con filo di Sonirallo di iic di ui di controlio Ai controllo di controlla di controllo RELA dr Operazioni facilitate grazie al pannello LCD Finger Touch Pannello touch con io semplice semplice wireless Ee e Ene Timer interno giornaliero settimanale ON OFF Temp Mod La retroilluminazione consente operazioni facilitate in ambienti oscurati Nome modello UTY RNRG UTY RLRG UTY RSKG UTY RHKG UTY LNHG UTY CGGG UTY DCGG UTY DTGG UTY ALGX UTY APGX Display temperatura nella stanza dispositivo remoto Disponibile in 7 diverse lingue inglese cinese francese tedesco spagnolo russo polacco Max unit interne controllabili 16 16 16 16 16 128 100 400 400 1600 Tipo a 2 fili Gruppi max controllabili 16 400 400 1600 Acceso Spento e e e e e e e o e o E iii e e e _ e e e e e e Alte prestazioni e dimensioni compatte Controllo preciso e nella massima comodit G Impostazione velocit ventola e Q e G e e e o e In aggiunta al controllo individuale e al timer settimanale i vari sistemi La temperatura interna pu essere monitorata con precisione con l inserimento i di controllo per il risparmio energetico sono disponibili utilizzando un solo di un termosensore nel corpo del dispositivo di controllo con filo Limitazione punto impostato temp ambiente e e
13. Me 7 pH Num max di piccole e medie dimensioni mas C bna net A on dee Schermo a colori TFT di grandi dimensioni 7 5 pollici Controllo individuale e monitoraggio di 100 unit interne cen RL 1 6 Operazioni facilitate Finger Touch sul LCD Schermo a colori TFT da 5 pollici Ripi fi wam y gruppi Design e forme d avanguardia ben adattabili a tutte le applicazioni Alta visibilit e operazioni facilitate e Contatto esterno ingresso uscita Non sono richiesti componenti aggiuntivi per l installazione possibile controllare fino a 400 unit interne Unit di alimentazione elettrica rimovibile 2 tipi di visualizzazioni selezionabili icone elenco in modalit monitoraggio S Ap in 7 diverse lingue inglese cinese francese tedesco spagnolo russo Disponibile in 7 diverse lingue inglese cinese francese tedesco spagnolo russo polacco Tipo a 2 fili Tipo a 2 fili Presentazione del sistema Operazioni facilitate Consente il raggruppamento multiplo di unit interne max 16 gruppi controllati Ampia gamma di icone di facile comprensione Gruppo l Interblocco con dispositivi esterni Cortile Le operazioni possono essere selezionate utilizzando le dita o la Touch Pen dedicata premendo sull icona desiderata che appare sullo schermo G 3F pini Visualizzazione aggiornata dello stato Gruppo Divisione A Gruppo Divisione B Gruppo Divisione
14. lo SN T R LN DN ha D mm Unit interna Eccc Adattatore USB da reperire su campo da reperire Ps po su campo Unit interna Funzioni Dettagli impianto diagramma x Dettagli impianto elenco Cronologia errori eDownload file da remoto Elenco sistema Strumento per la messa in opera Requisiti di sistema del PC UTY ASGX Microsoft Windows Vista Home Premium 32 bit SP2 Windows Vista Business 32 bit SP2 Microsoft Windows 7 Professional 32 bit o 64 bit SP1 r NA OPE ra Microsoft Windows 8 Pro 32 bit o 64 bit CPU 1 GHz or higher Memoria For Windows Vista Windows 7 32 bit e Windows 8 32 bit 1 GB o maggiore For Windows 7 64 bit e Windows 8 1 64 bit 2 GB o maggiore HDD Spazio libero maggiore o uguale a 10 GB Display Risoluzione maggiore o uguale a 1024 x 768 2 porte USB Interfaccia 1 porta USB necessaria per la chiave Wibu 1 porta USB necessaria per l interfaccia di rete Echelon U10 USB Software Internet Explorer 8 0 o 9 0 o 10 0 Adobe Reader 9 0 o successiva Unit ottica Unit DVD ROM lt Elenco imballaggio gt Nome e forma Quantit Applicazione DVD ROM 1 Include software e manuali Chiave WIbu 1 Chiave protezione software da collegare alla porta USB sul Service Tool installaz PC Chiave protezione software Questi prodotti funzionano unicamente su PC dotati di chiave Wibu
15. richiesta l alimentazione esterna autonoma Utilizzabile per unit interne singole e unit interne controllate a gruppi fino a 16 Unit interna a Smartphone Tablet Router Fornito su campo PC Internet Interfaccia LAN wireless Controllo di base e Accensione e spegnimento delle unit e Controllo modalit caldo freddo asciutto autom ventola e Impostazione velocit ventola e Posizione alette impostazione direzionamento del flusso d aria e Display temperatura nella stanza e Controllo temperatura impostata z f D Multi lingue Visualizzazione unica e timer Controllo avanzato Funzioni opzionali Notifiche e cronologia Modalit lavoro in base al clima ECO Comfort Potente versione futura Notifica via e mail degli allarmi versione futura Funzionalit programmabili ACCENSIONE SPEGNIMENTO modalit punto Allarmi sul malfunzionamento del climatizzatore impostato temperatura velocit ventola posizione feritoia Monit llarmi tivit Monitoraggio e allarmi connettivit Limite temperatura impostata versione futura s Cionolegia versione futura Visualizzazioni e timer multipli e funzione di calendario Specifiche Nome modello FJ RC WIFI 1 Dimensioni A x L x P mm 70x108x28 Peso g 80 069 Adattatore e convertitore unit controllabili Dispositivo di controllo interruttore esterno UTY TEKX 1 Convertitore di
16. Sono possibile varie impostazioni del timer ACCESO SPENTO SETTIMANALE La temperatura ambiente pu essere controllata monitorando con attenzione la temperatura grazie al termosensore integrato In caso di malfunzionamento viene visualizzato il codice dell errore Cronologia errori possibile accedere agli ultimi 16 codici degli errori Tipo a 2 fili Alte prestazioni e dimensioni compatte In aggiunta al controllo individuale e al timer settimanale i vari sistemi di controllo per il risparmio energetico sono disponibili utilizzando un solo dispositivo di controllo remoto Controllo Termo Timer Timer individuale sensore spegnimento automatico settimanale Timer spegnimento automatico L unit interna si spegne automaticamente una volta trascorso l intervallo temporale impostato Stato Operativo SPEGNIMENTO SPEGNIMENTO automatico automatico ON REA OFF Il timer di spegnimento automatico pu essere impostato da 30 a 240 minuti Funzione timer settimanale Oltre all attivazione e disattivazione della fascia oraria impostabile possibile impostare la modalit operativa e la temperatura grazie alla funzione del timer settimanale ACCESO SPENTO ACCESO SPENTO Y Ore di lavoro Ore di lavoro 8 00 12 00 13 00 17 00 i 4 tipi ACCENSIONE SPEGNIMENTO ACCENSIONE SPEGNIMENTO possono essere impostati ogni giorno della settimana in una settimana Specifiche Nome modell
17. UTY ALGX UTY APGX Convertitori adattatori Dispositivi esterni Gateway BACnet UTY ABGX DVD ROM Chiave di Software potezione software Convertitore di rete per L oNWORKS UTY VLGX Interfaccia KNX FJ RC KNX 1i Interfaccia MODBUS FJ RC MBS 1 Per espansione sistemi Interfaccia LAN wireless FJ RC WIFI 1 Convertitore di rete UTY VGGXZ1 Amplificatore di segnale UTY VSGXZ1 Pannelli Per tipo a cassetta Griglia cassetta UTG UFGC W Per tipo a cassetta compatta Griglia cassetta UTG UGGA W Per tipo a cassetta Interrutore esterno UTY TEKX 078 PARTI OPZIONALI per vRF Altro Sistema di comunicazione kit collegamento Per unit interne utvxwzxz7 B E SUONO p E Per unit RB Ur xwzxzE E E Per dispositivo di controllo remoto centrale urc xwzxz B E UTY XWzxzo E ES Elenco funzioni Per unit esterne uTtv xwzxze E E ea a Per dispositivo di controllo con pannello touch Dispositivo di controllo Altro Per canalizzati Flangia rotonda UTD RF204 Per tipo canalizzato pressione statica media tipo soffitto Filtro a vita prolungata UTD LF25NA Per tipo canalizzato pressione statica media UTD LF60KA Per tipo canalizzato pressione alta statica
18. fino alla progettazione delle tubature e degli allacci stato semplificato grazie alle funzioni interne del programma Una volta ultimata la progettazione grazie alla funzione di esportazione possibile ottenere con facilit gli elenchi dei materiali le specifiche del prodotto i calcoli sulla refrigerazione e altro ancora le esportazioni sono inoltre possibile nei formati Word e Excel ed possibile raggruppare i dati CAD rilevanti Informazioni sulla selezione del modello creato automaticamente Ciascuna unit pu essere impostata automaticamente inserendo le prestazioni desiderate le tipologie e le condizioni di temperatura per ciascun porta interna trascinando quindi tali informazioni e applicandole anche all unit esterna diagrammi sui cablaggi e sulle tubature possono essere creati automaticamente e l impostazione di opzioni raggruppamenti diramazioni risulta facilitata La quantit di refrigerante aggiuntivo da caricare viene calcolata automaticamente una volta inserita la lunghezza del tubo Inoltre facile impostare i gruppi di dispositivi remoti di controllo dispositivi di controllo centrali e convertitori L elenco dei dispositivi comprendente le informazioni su ciascun dispositivo viene quindi creato automaticamente Produzione nel formato che corrisponde all applicazione m CE i Le informazioni specifiche per ciascun progetto possono essere mui i E Baro esportate in vari format
19. funzioni risparmio energetico a Funzionamento risparmio P energetico Imposta temp Funzionamento risparmio lt a Temperatura controllo Sa energetico funzione risparmio energetico 14 TEE EEEE T max zc Impostazione temperatura di raffreddamento set point Impostazione limitazione impostato set point Funzionamento con risparmio di capacit Il funzionamento pu essere impostato a 5 stadi in base al livello di capacit Il consumo energetico di picco viene ridotto e il carico massimo viene limitato Timer spegnimento automatico e L unit interna viene automaticamente disattivata quando si raggiunge la fascia oraria prestabilita La fascia oraria del timer di spegnimento automatico pu essere programmata in modo molto flessibile Capacit FREE Impostazione i Impostazione priorit Impostazione fascia oraria intervallo capacit MERE EE ACCESO automatico 100 ERO OD x 80 Impostazione tempo T z spegnimento L 60 da 30 a 240 minuti 40 0 Tempo 016 Maggiore comfort Controllo preciso sul flusso del refrigerante II controllo preciso sull uniformit di flusso del refrigerante possibile grazie al sistema di controllo tramite inverter DC unitamente al sistema di controllo con valvola di espansione elettrica per la singola unit interna Questo consente un controllo ad alta precisione con margin
20. il timer del programma attiva il timer di ACCENSIONE e SPEGNIMENTO una volta entro un periodo di 24 ore Timer veglia la funzione Timer notte corregge automaticamente la temperatura impostata in base all impostazione dell orario cos da evitare un eccessivo raffreddamento o riscaldamento durante le ore di sonno Installazione e operazioni facilitate Il selettore dei codici evita possibili confusioni tra le unit interne possibile impostare fino a 4 codici Intervallo di trasmissione ampio e preciso Unit ricevitore IR UTB YWC Necessario per controllare tutti i tipi di canalizzati tramite il dispositivo di controllo remoto wireless Indirizzamento sistema In fase di installazione l indirizzamento del sistema pu essere svolto utilizzando il dispositivo di controllo remoto wireless eliminando pertanto le impostazioni di selezione manuale T Oo Mi a Unit esterna Unit ricevitore IR Linea di trasmissione Unit interna Dispositivo di controllo wireless E n xS Unit interna x DE M con canalizzabili DS 271 Dispositivo di controllo remoto wireless Unit ricevitore RI UTY LRHGB1 E possibile controllare l unit interna del tipo a cassetta con un dispositivo di controllo OR PASO AER remoto wireless wireless Specifiche Nome modello UTY LNHG UTB YWC UTY LRHGB1 B
21. opzioni di controllo per la gestione degli edifici Dispositivo di controllo del sistema Dispositivo di controllo con UTY APGX un AR ns pannello touch UTY ALGX Edizione Lite rn UTY DTGG e Fornito su campo Controllo individuale Internet o linea pubblica del telefono Dispositivo di controllo con filo Pannello touch UTY RNRG Dispositivo di controllo remoto centrale UTY DCGG Per tutte le serie AIRSTAGETM Lato monitoraggio remoto Dispositivo di controllo con filo UTY RLRG Dispositivo di controllo remoto di gruppo UTY CGGG Convertitore Adattatore per dispositivo esterno P Convertitore di rete TE UTY VGGXZ1 Gateway BACnet software Pi UTY ABGX l Di itivo di troll li JE Adattatore USB 2 E ispositivo di controllo semplice ko LT II ar 1 UTY RSKG lt Mor 1 E BMS BAS oJ T VAL Accessorio non fornito LI eL E ES Convertitore di rete BMS LON WORKS UTY VLGX Pp Dispositivo di controllo semplice UTY RHKG Funzionalit limitate Interfaccia KNX FJ RC KNX 1i BMS Sistema domotica Dispositivo di controllo wireless UTY LNHG Interfaccia MODBUS FJ RC MBS 1 Interfaccia LAN wireless EM FJ RC WIFI 1 Dispositivo Strumento per la
22. 123 5 kW 44HP AJH396GALH UNIT AJH144 144 108GALH 130 0 kW 46HP AJH414GALH UNIT AJH144 144 126GALH 135 0 kW 48HP gt C M e AJH432GALH UNIT AJH144 144 144GALH Combinazione in funzione della resa energetica 44 8 kW 16HP nc x r Ww AJH144GALHH UNIT AJHA72 A72GALH 62 4 kW 22HP lt e e T pr AJH198GALHH UNIT AJH126 A72GALH 67 2 kW 24HP a T T oW w AJH216GALHH UNIT AJHA72 A72 A72GALH 72 8 kW 26HP r w w AJH234GALHH UNIT AJHA90 A72 A72GALH 78 4 kW 28HP w w gt mr AJH252GALHH UNIT AJHA90 A90 A72GALH 84 0 kW 30HP i w a w gl AJH270GALHH UNIT AJHA90 A90 A90GALH 90 4 kW 32HP x m AJH288GALHH UNIT AJH126 A90 A72GALH 96 0 kW 34HP Fr A e M eg _ AJH306GALHH UNIT AJH126 A90 A90GALH 102 4 kW 36HP mi is mz 2 x w AJH324GALHH UNIT AJH126 126 A72GALH 108 0 kW 38HP w o F wr AJH342GALHH UNIT AJH126 126 A90GALH 113 0 KW 40HP a AJH360GALHH UNIT AJH144 126 A90GALH 120 0 kW 42HP T lw w w wm a w AJH378GALHH UNIT AJH126 126 126GALH 125 0 kW 44HP AJH396GALHH UNIT AJH144 126 126GALH Di
23. 37 38 41 50 Media dB A 28 30 30 30 34 34 35 44 Bassa 21 25 25 25 27 27 27 30 Dimensioni A x L x P mm 245 x 570 x 570 Peso kg 15 17 Diametro linee Liquido svasato 26 35 29 52 frigorifere Gas svasato mm 612 70 015 88 Tubo di scarico VP 225 D I 632 D E Griglia Nome modello UTG UFGC W cassetta Dimensioni AxL x P 50 x 700 x 700 Peso 2 6 Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Tensione 230 V 1 questo valore in ciclo raffreddamento Cassetta Nome modello AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH Alimentazione VIDIHZ 230 1 50 Capacit Raffreddamento 5 6 LA 9 0 11 2 12 5 14 0 Riscaldamento 8 0 10 0 12 5 14 0 16 0 Potenza d ingresso 46 59 80 99 119 Portata flusso dell aria Alta 1 280 1 600 1 800 1 900 2 000 Media 1 040 1 300 1 300 1 970 1 370 Bassa 870 1 100 1 100 1 100 1 100 Livello pressione sonora Alta 38 40 44 46 47 Media 33 38 38 39 39 Bassa 29 33 33 33 33 Dimensioni A x L x P mm 246 x 840 x 840 288 x 840 x 840 Peso kg 22 27 Diametro linee Liquido svasato 99 52 frigorifere Gas svasato mm 215 88 219 05 Tubo
24. 45 48 48 48 48 48 48 48 48 48 Capacit unit interna collegabile Raffiedde kw 16 8 50 2 20 0 60 0 22 5 675 252 756 33 5 100 5 36 8 110 2 39 3 117 7 42 5 127 5 45 0 135 0 47 5 142 5 50 3 150 7 53 5 160 5 56 0 168 0 59 3 177 7 61 8 185 2 65 0 195 0 67 5 202 5 Alimentazione 3 fasi 4 fili 400 V 50Hz 3 fasi 4 fili 400 V 50Hz Gia Meme Luv 22 4 28 0 33 5 40 0 45 0 50 4 55 9 61 5 67 0 73 5 78 5 85 0 90 0 95 0 100 5 107 0 112 0 118 5 123 5 130 0 135 0 Riscalda 25 0 31 5 37 5 45 0 50 0 56 5 62 5 69 0 75 0 82 5 87 5 95 0 100 0 106 5 112 5 120 0 125 0 132 5 137 5 145 0 150 0 WWW Ree o 23 79 25 70 28 34 26 97 28 86 30 77 37 96 39 87 42 51 Riscalda 5 72 7 83 9 28 11 45 12 60 13 55 15 00 17 11 18 56 20 73 24 05 25 20 26 39 27 84 34 48 36 65 37 80 EER Raffredda 4 07 3 62 3 48 3 47 3 18 3 81 3 69 3 54 3 48 3 48 3 31 3 18 3 52 3 48 3 25 3 26 3 18 COP EE a 4 37 4 02 4 04 3 93 3 97 4 17 4 17 4 03 4 04 3 98 3 95 3 97 4 04 4 04 3 99 3 96 3 97 Portata flusso dell aria Alta m h 11 100 11 100 11 100 13 000 13 000 11 100 x 2 11 100 x 2 11 100 x 2 11 100 x 2 13 000 11 100113 000 11 400 13 000x2 13 000x2 11 100x 3 11 100x3 13 000 11 100 x 213 000 11 100 x 213 000 x 2 11 10013 000 x 2 11 100 13 000 x3 13 000x3 Livello pressione Raffredda qB 58 58 60 61 60 60 61 61 62 64 64 63 63 65 65 66 sonora Riscalda A 59 60 61 61 62 62 63 63 64 64 64 64 65 65 66 66 Pressione statica estena massima Pa 80 80 80 80 80 80 80 80
25. ARXC36GATH ARXC45GATH ARXC60GATH ARXC72GATH ARXC90GATH Universale i ABHA12GATH ABHA14GATH ABHA18GATH Canalizzato ad incasso Pavimento installazione verticale dati come versione i canallizzato slim ARXB07GALH ARXBO9GALH ARXB12GALH ARXB14GALH ARXB18GALH Canalizzato ad incasso installazione verticale come versione canallizzato slim ARXD04GALH ARXDO7GALH ARXD12GALH ARXD14GALH 3 h S pap Soffitto Soffitto pa p le ABHA12GATH ABHA14GATH ABHA30GATH ABHA36GATH ABHA45GATH ABHA54GATH Parete con valvola Bone esp incorporata Parete ASHA18GACH ASHA24GACH ASHA30GACH Parete valvola espansione EEV esterna ASHE04GACH ASHEO7GACH ASHEO9GACH ASHE12GACH ASHE14GACH Con questo modello necessario il collegamento con il Kit EV i modelli ARXC60 72 90LATH non sono collegabili alle serie J IIS e J Il 047 Specifiche unit interne Cassetta Compatta k LUN qe Nome modello AUXB04GALH AUXB07GALH AUXBO9GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH Alimentazione V Q Hz 230 1 50 Capacit Raffreddamento 1 1 2 2 2 8 3 6 4 5 5 6 7 1 Riscaldamento dd 8 0 Potenza d ingresso W 84 Portata flusso dell aria Alta 1 030 Media m3 h 420 450 450 450 530 590 580 830 Bassa 300 350 350 350 390 390 400 450 Livello pressione sonora Alta 34 34 35
26. Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Altezza 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 Dimensioni Larghezza 930x2 1 2404930 930x3 930x3 930x3 930x3 1 2404930x2 1 2404930x2 1 240x2 930 1 240x2 930 1 240x2 930 1 240x3 1 240x3 Profondit 765 765 765 765 765 765 765 Peso kg 286 262 286 262x2 286 262x2 286x2 262 286x2 262 286x2 262 286x3 286x3 Carica refrigerante kg 11 8x2 11 8x3 11 8x3 11 8x3 11 8x3 11 8x3 11 8x3 11 8x3 f l Liquido 15 88 19 05 19 05 19 05 19 05 19 05 19 05 19 05 Piro Ines Gas scarico mm 28 58 28 58 28 58 28 58 34 92 34 92 34 92 34 92 frigorifere Gas suzione 28 58 34 92 34 92 34 92 34 92 34 92 34 92 34 92 41 27 41 27 41 27 41 27 41 27 Limiti e da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 da 10 a 46 operativi Aei CDB da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 Raffreddamento da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6
27. C DUE 0 N colori sullo sfondo identificano le diverse operazioni di controllo blu per monitoraggio verde per controllo operativo re n o o w lee e isst Ui UE eue E Pea Funzioni Versatilit Group 2F Funzione arresto di emergenza condizionatore d aria pu essere j spento tramite il dispositivo di controllo esterno Gruppo Condomino A Gruppo Condomino B Gruppo Condomino C dati registrati possono essere trasferiti tramite la porta USB dati in formato CSB modificati dal PC possono essere importati nel dispositivo di controllo con pannello Touch dati in formato CSB modificati dal PC possono essere importati nel dispositivo di controllo Funzione con pannello Touch arresto di emergenza Funzione arresto di emergenza Trasferimento dati tramite USB eg Impostazione modello 1 Impostazione modello 2 Installazione facilitata n Soffitto pannello di controllo e l unit di alimentazione possono essere installati Unit dw e p distintamente fr di alimentazione L Controllo programma Monitoraggio operazioni unit interne Pas d i HP w Scatola M WSQ elettrica f f f Installazione facilitata Per la flessibilit dell installazione il pannello di controllo pu essere integrato Interruttori agi Dez Regolazione automatica dell orologio m E
28. CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Quando le operazioni di raffreddamento vengono svolte con temperatura esterna dell aria inferiore a 5 C l unit esterna deve essere installata in una posizione che risulti maggiore o uguale a quella delle unit interne 1 Il numero minimo di unit interne collegabili 2 2 Il valore sonoro corrisponde al valore misurato in una camera anecoica Quando misurati nello stato effettivo di installazione e il valore misurato pu essere diverso rispetto al valore indicato 045 046 Gamma unit interne 12 tipi 55 modelli intervallo capacit da 1 1 kW a 25 0 kW Capacit kW 1 1 2 2 2 8 3 6 4 5 5 6 7 1 9 0 11 2 12 5 14 0 18 0 22 4 25 0 Codice modello 7 12 14 18 24 60 72 90 c E lt EN lt 2 x C i Je E Cassetta Compatta a Nas av Na k W gas Cassata AUXBOAGALH AUXBO7GALH AUXBO9GALH AUXB12GALH AUXB14GALH AUXB18GALH AUXB24GALH Cassetta E ku AUXD18GALH AUXD24GALH AUXA30GALH AUXA36GALH AUXA45GALH AUXA54GALH pressione statica ARXB07GALH ARXBO9GALH ARXB12GALH ARXB14GALH ARXB18GALH uie e con pompa di scarico Canalizzati ARXD07GALH ARXD09GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH Canalizzato a media v rere pressione statica l ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH Canalizzato ad alta i Fy pressione statica
29. Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Tensione 230 V Nome modello ASHA04GACH ASHA07GACH ASHA09GACH ASHA12GACH ASHA14GACH ASHEO4GACH ASHE07GACH ASHEO9GACH ASHE12GACH ASHE14GACH Alimentazione VIDIHZ 230 1 50 230 1 50 Capacit Raffreddamento kW 1 1 2 2 2 8 3 6 4 5 1 1 2 2 2 8 3 6 4 5 Riscaldamento 1 3 2 8 3 2 4 1 5 0 19 2 8 3 2 4 1 5 0 Potenza d ingresso W 13 17 18 22 34 12 16 21 34 Portata flusso dell aria Alta 490 500 450 490 500 560 680 Media m h 370 440 450 450 370 440 450 450 480 490 Bassa 320 420 370 420 370 420 300 420 370 420 370 420 420 420 Livello pressione sonora Alta 33 35 36 32 34 35 38 43 Media dB A 27 32 33 33 35 37 26 31 32 32 34 35 Bassa 221317 27 31 1 27 31 1 31 32 19 30 26 30 26 30 30 30 Dimensioni A x L x P mm 275 x 790 x 215 275 x 790 x 215 Peso kg 9 9 Diametro linee Liquido svasato 26 35 26 35 frigorifere Gas svasato mm 912 70 912 70 Tubo di scarico 213 8 D I 215 8 216 7 D E 213 8 D I 215 8 216 7 D E Kit EV opzione E UTR EV09XB UTR EV14XB Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Ri
30. alto Porta tubo 036 Specifiche unit esterne Combinazione in funzione dell economia di spazio 42 44 46 48 Range di potenza HP 8 10 12 14 16 18 20 22 24 26 28 30 32 34 36 38 40 Nome modello AJHA72LALH AJHA9OLALH AJH108LALH AJH126LALH AJH144LALH AJH162LALH AJH180LALH AJH198LALH AJH216LALH AJH234LALH AJH252LALH AJH270LALH AJH288LALH AJH306LALH AJH324LALH AJH342LALH AJH360LALH AJH378LALH AJH396LALH AJH414LALH AJH432LALH Unit 1 AJHA72LALH AJHA90LALH AJH108LALH AJH126LALH AJH144LALH AJHA90LALH AJH108LALH AJH108LALH AJH108LALH AJH126LALH AJH144LALH AJH144LALH AJH144LALH AJH108LALH AJH108LALH AJH126LALH AJH144LALH AJH144LALH AJH144LALH AJH144LALH AJH144LALH Unit 2 AJHA72LALH AJHA72LALH AJHA90LALH AJH108LALH AJH108LALH AJH108LALH AJH126LALH AJH144LALH AJH108LALH AJH108LALH AJH108LALH AJH108LALH AJH126LALH AJH144LALH AJH144LALH AJH144LALH Unit 3 AJHA90LALH AJH108LALH AJH108LALH AJH108LALH AJH108LALH AJH108LALH AJH126LALH AJH144LALH Livello massimo unit interna collegabile 17 21 24 32 35 39 42
31. dettagli operativi e dello stato di errore senza utilizzare alcuno strumento specifico LED 7 segmenti e Stato modalit operativa e Temperatura di scarico Stato pressione e Indicazione operazioni compressore e Indirizzo Tipo Numero dell unit esterna esterna Diagnosi errori con il Service Tool Collegamento al Service Tool e Lo stato delle operazioni in dettaglio e la cronologia degli errori recenti possono essere controllati e analizzati utilizzando il Service Tool e Inoltre possibile registrare la memoria delle funzioni degli ultimi 5 minuti Unit esterna Linea di trasmissione Service Tool UTY ASGX Unit interna e Adattatore USB non incluso Pannello PCB mobile Lavori di manutenzione facilitati dietro il PCB Visualizzazione di errori e quantit Codice errore indirizzo anomalie unit interna Lo stato di errore pu essere facilmente fumi controllato tramite il display dell unit Lo stato dell errore pu essere facilmente individuato tramite il dispositivo di controllo a filo dell unit interna Un codice di errore viene visualizzato sullo schermo a cristalli liquidi Dispositivo di controllo con filo Numero sistema 001 Dispositivo di controllo Codi 002 Unit interna odice errore Numero unit Dispositivo di controllo semplice Indirizzo dispositivo di controllo remoto Codice
32. di calore Blue Fin La resistenza alla corrosione dello scambiatore di calore stata migliorata grazie all introduzione del trattamento Blue Fin nello scambiatore dell unit esterna Scambiatore di calore Blue Fin Protezione blu cobalto Protezione cromatura standard Materiale base alluminio Rivestimento idrofilico L ordine di avvio dei compressori viene fatto ruotare cos che il tempo di lavoro possa essere ripartito Rotazione Rotazione Rotazione rene j oe a Jd LE e us Nota compressori inverter iniziano in priorit L operazione di rotazione viene alternata dal tempo di avvio e arresto dei compressori Operazioni di backup Nel caso in cui un compressore non dovesse funzionare le operazioni di backup verranno svolte dai compressori rimanenti Nota Le operazioni di backup potrebbero non essere possibili a seconda dello stato dell avaria m m u um um mm e m um
33. di scarico VP25 225 D I 932 D E Griglia Nome modello UTG UGGA W cassetta Dimensioni mm 50 x 950 x 950 Peso kg Di Nota le specifiche si basano sulle condizioni seguenti 048 Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Tensione 230 V Canalizzato a bassa pressione statica Installazione orizzontale e verticale Nome modello ARXB07GALH ARXBO9GALH ARXB12GALH ARXB14GALH ARXB18GALH Alimentazione VIDIHZ 230 1 50 Capacit Raffreddamento 2 2 2 8 3 6 4 5 5 6 Riscaldamento 4 0 5 0 6 3 Potenza d ingresso 63 90 96 Portata flusso dell aria Alta 590 800 890 Media 750 810 450 700 730 Intervallo pressione statica da 0 a 50 da 0 a 50 da 0 a 50 da 0 a 50 da 0 a 50 Pressione statica standard 25 25 25 25 25 Livello pressione Alta 29 31 30 33 36 sonora Media 26 29 28 32 34 Bassa 24 27 25 30 30 Dimensioni A x L x P 217 x 663 x 595 217 x 953 x 595 Peso 15 23 Diametro linee 06 35 29 52 frigorifere Gas svasato mm 912 70 215 88 Tubo di scarico VP25 925 D I 632 D E Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CW
34. errore Dispositivo di controllo con filo Pannello touch Stato errore Cronologia errore Error History Page 1 3 No Date Time Address Code Next Erase Page AII Monitoraggio remoto Il sistema di monitoraggio in rete consente di monitorare il funzionamento del sistema in qualsiasi momento tramite Internet garantendo un funzionamento senza problemi Schermata di monitoraggio f Sistema di rete VRF Unit esterna Linea di trasmissione Internet o linea pubblica del telefono Adattatore USB fornito su campo Strumento di monitoraggio web Unit interna IN p Il sistema della rete VRF operativa nell edificio pu essere monitorato in tempo reale tramite Internet 021 022 Pompa di calore AJHO40LCLAH AJHOASLCLAH AJHOS4LCLAH General offre sistemi di aria condizionata per una ampia gamma di applicazioni da piccoli edifici adibiti ad uffici ed esercizi commerciali ad abitazioni domestiche di grandi dimensioni Caratteristiche Caratteristiche Pu essere trasportato con facilit Modello attuale cl Altezza 1334 mm Peso 117 kg LI 1 L LI E m m ANO s G m m JJ m s zs Unit esterna di piccole dimensioni e peso contenuto Questo modello molto pi compatto rispetto alle unit esterne convenzionali 6HP r
35. in Medio Oriente EAU Societ di vendita in Nuova Zelanda 2011 2012 Modello con design altamente Tipo recupero di calore VRF specializzato F IRSTAGE YR ARSTAGE J IT 2006 2007 Stabilimento produttivo di Stabilimento tecnologico sui vendita e assistenza per i condizionatori d aria completato condizionatori d aria VRF sugli uffici centrali del gruppo in Cina 2002 Societ di vendita a Taiwan 2006 Societ di vendita a Cina 2014 Serie VRF piccolo AIRSTAGE j IIS Inizio dell attivit dello stabilimento produttivo 3 dei compressori in Tailandia 2012 Joint venture con Toshiba Carrier Corporation 005 006 Strutture e strumenti d avanguardia per la ricerca Collaudi di funzionamento Collaudo sonoro Collaudo calorimetro f e Collaudo flusso d aria Trasporto e movimentazione Test di comprimibilit Test vibrazioni Collaudi di affidabilit Severi collaudi ambientali Centro ricerca e sviluppo A QUALIT DEGLI AMBIENTI DI PROGETTAZIONE E SVILUPPO Laboratori di collaudo Fujutsu General laboratorio CEM Sito per i test internazionali sulla CEM Torre di collaudo di altezza 60m L obiettivo verificare la circolazione d olio nel compressore per una massima affidabilit ASSICURAZIONE ALTA QUALIT Assicurazione alta qualit Assicurazione qualit prodotti Tutti gli stabi
36. ita cgarr BELEET ENTE Unit RB Pulsante di settaggio sull unit esterna Accesso facile tempo di installazione ridotto per accesso frontale 4 vie di accesso per le tubazioni Utilizzando un pannello frontale a forma di L che pu successivamente essere rimosso l area di lavoro per l installazione e la manutenzione risulta considerevolmente ampliata grazie a questa nuova disposizione Per installazioni multiple il lavoro viene svolto in modo facile ed efficiente anche in spazi ristretti fi A T 7 Tn D ay XY A VA WV Jy 7 R V A 2 IN W n A W Wi x Ww QW Z M VA NV N ANN i M X 1 AN QA y PA W 1 W 7 X 7 N o GA 2 X Gli indirizzi vengon e AV V V A DX 5 N K VA AAA N VA o Q V A VA g O Espansione dell area di lavoro Collegamento seriale automaticamente generati dall unit esterna Amplificatore segnale Fino alla massima lunghezza di 3 600 m inoltre possibile l impostazione manuale dell indirizzo dall unit interna e dal dispositivo di controllo remoto 020 Manutenzione e riparazione facile Progettate per una facile manutenzione LED a 7 segmenti di facile lettura conferma dei
37. manutenzione e riparazione Chiave scheda Internet Dispositivo di controllo interruttore esterno Service Tool UTY TEKX UTY ASGX Fornito su campo 1 BMS BAS Sistema di gestione degli edifici Sistema di domotica 2 Adattatore USB Interfaccia di rete U10 USB Echelon Sistema di monitoraggio web UTY AMGX Lato di monitoraggio Lato sistema di rete VRF Unit esterna Linea di trasmissione Strumento di monitoraggio web Convertitore Adattatore per espansione del sistema Internet o linea pubblica deltelefono Adattatore USB I x i E I pen ni Convertitore di rete MOROSENI Amplificatore ams Sistema di rete VRF esteso Fornito su campo k l ns HEU di segnale s E UTY VGGXZ1 UTYVSGXSI Unit interna 052 053 Dispositivi di controllo Num max s ja ssi d controllabile Tabella di confronto dei dispositivi di controllo i 1 6 Dispositivo di controllo con filo Pannello touch UTY RNRG E mes ET Al pum au m Unit interne ET A Hu C gt Operazioni facilitate grazie al grande pannello Touch Screen STN LCD TIPOLOGIA E s n n Dispositivo di
38. massimo di 101 configurazioni per ciascun gruppo di dispositivi di controllo remoto Le impostazioni possono essere effettuate per periodi a cavallo della mezzanotte Consente la programmazione speciale per festivit incluse feste nazionali per un intero anno Operazioni programmabili con bassi livelli di rumore di unit interne Controllo diversificato dell unit interna Viene visualizzato lo stato operativo dell unit interna la modalit operativa ecc Selezione dell accensione spegnimento dell unit interna e della modalit operativa Limitazione punto impostato temperatura ambiente Blocco dispositivo di controllo remoto Questa funzione blocca le variazioni alla modalit operativa alla temperatura all accensione spegnimento ecc Distribuzione rete elettrica Struttura di calcolo della distribuzione della rete elettrica Se si vuole conoscere l elettricit consumata dai condizionatori d aria di ciascun condomino dalla rete elettrica per ciascun mese Grazie alla funzione di distribuzione della rete elettrica viene visualizzato il livello di distribuzione dell energia utilizzata calcolando in dettaglio l energia consumata dalle unit utilizzate da ciascun condomino Queste informazioni vengono quindi utilizzate per calcolare il livello di elettricit consumata per il condizionamento d aria di ciascun condomino dal livello di elettricit totale come da fattura emessa dalla soci
39. nel muro o fissato sulla parete E ug Jl Bennel NE ON dispositivo di controllo del pannello Touch viene AH L ora su ciascun dispositivo au 7 7 i i i ELCHE PUT css nn B NEO a e La superficie posteriore piana consente di installarlo Pannello di controllo Unit alimentazione elettrica Parete impostata automaticamente i dovunque necessario I sul gruppo Non sono richiesti componenti aggiuntivi per Funzioni l installazione e Controllo diversificato delle unit interne Timer settimanale Regolazione automatica dell orologio Cronologia errori Specifiche Specifiche Nome modello UTY DCGG Nome modello UTY DTGG Pannello di controllo Unit di alimentazione elettrica Alimentazione elettrica 100 240 V 50 60Hz monofase Alimentazione elettrica DC5V 100 240 V 50 60Hz monofase Dimensioni A x L x P mm 260 x 246 x 54 Dimensioni A x L x P mm 120 x 162 x 25 7 99 x 135 x 39 2 Peso g 2 150 Peso g 308 355 Interfaccia USB 2 0 ELENCO IMBALLAGGIO gt Elenco imballaggio Pannello di controllo Unit alimentazione elettrica Cavo di collegamento ecc 060 061 Dispositivi di controllo Num max controllabile Dispositivo di controllo del sistema UTY APGX sistemi di rete 5 k Num max II dispositivo di controllo del sistema consente di realizzare il monitoraggio E controllabile integrato avanzato e il controllo del sistema di rete VRF in edifici
40. rete UTY VGGXZ1 del convertitore La commutazione del climatizzatore pu essere effettuata con la connessione ad un sensore remoto Insieme all interruttore con chiave a scheda fornito su campo o altro sensore il dispositivo di controllo per la selezione esterna consente il controllo della temperatura in ambiente della funzione di ACCENSIONE SPEGNIMENTO della Questo convertitore di rete deve essere utilizzato per collegare sistemi monosplit o dispositivi di controllo remoto velocit della ventola e del controllo generale Questo rende il prodotto idoneo per installazioni tipo stanze di hotel Y dei gruppi con il sistema di rete VRF eLa chiave a scheda o altri interruttori a sensore sono disponibili come componenti forniti su campo Selezionare la funzione utilizzando il Dip Switch durante l installazione Esempio di installazione Cablaggio elettrico Esempio di installazione Chiave scheda sistemi di tipo split sono controllabili da un dispositivo di controllo remoto centralizzato o dispositivo di controllo da PC tramite collegamento al convertitore Le funzioni in modalit automatica che selezionano automaticamente Raffreddamento E TIF 2 gt Z eOC l opzione di riscaldamento o raffreddamento vengono abilitate utilizzando di rete VRF l interruttore a sensore e il dispositivo di controll
41. 0 kW J Il collegabile fino a 14 0 kW ue lt a Cem a Cassetta compatta Gassel Canalizzabile a bassa Canalizzabile sottile Canalizzabile a media pressione statica con pompa di scarico pressione statica n Canalizzabile ad alta I I I A parete pressione statica Pavimento Soffitto Soffitto pong valvole d espansione A parete esterna o interna all unit NOIE 3 nuovi modelli di unit interne canalizzabili 014 eSti TAHT Sistema a portata variabile Sistema a portata variabile VRF VR II 3 tubi per VRF V II due tubi funzionamento simultaneo riscaldamento e condizionamento Sistemi per grandi uffici e hotel e grandi Sistemi compatibili con modalit di controllo per operazioni plessi strutturali singole nonch per grandi uffici hotel e plessi strutturali di dimensioni considerevoli 34 modelli 8HP 48HP e Composizione per risparmio dello spazio 8HP 48HP 21 modelli e Composizione ad efficienza energetica 16HP 44HP 13 modelli ARSTAGE VIT ARSTAGE R II 33 modelli 8HP 48HP Composizione per risparmio dello spazio 8HP 48HP 21 modelli Composizione ad efficienza energetica 16HP 44HP 12 modelli Varie soluzioni di controllo di facile utilizzo Le necessit dell utente vengono supportate offrendo una ampia gamma di soluzioni di controllo tra cui controllo individuale controllo centrale nonch opzioni di controllo per la gestione degli edifici NOVIT
42. 0x2 1 240x2 1 240 930x2 1 240 930x2 1 240x2 930 1 240x2 930 1 240x3 1 240x3 Profondit 765 765 765 765 765 765 765 765 765 765 Peso 286 262 286 262 286x2 286x2 286 262x2 286 262x2 286x2 262 286x2 262 286x3 286x3 Carico refrigerante 11 8x3 11 8x3 11 8x3 Liquido 19 05 19 05 19 05 Diamentro linee Gas scarto 34 92 34 92 34 92 frigorifere Gas suzione 41 27 41 27 41 27 mm Rafiredda da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10 a 46 da 10 a 46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a46 da 10a 46 operativi Riscalda CDB da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20 a21 da 20a 21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a21 da 20a 21 Raffreddamento da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 da 10 a 21 Combinazione in funzione della resa energetica Kongo d poteiza HP 16 22 24 26 28 30 32 34 36 38 40 42 44 Nome modello AJH198GALHH AJH216GALHH AJH234GALHH AJH252GALHH AJH270GALHH AJH288GALHH AJH306GALHH AJH324GALHH AJH360GALHH AJH378GALHH AJH396GALHH Unit 1 AJHA72GALH AJH126GALH AJHA72GALH AJHA90GALH AJHA90GALH AJHA90GALH AJH126G
43. 1 UTY PLGXE1 ipei unit piis Orario DVD ROM 1 1 1 _ I Li Senermnofolazione Unita lmema aii Chiave Wibu Schiave protezione software 1 1 1 1 1 Chiave di protezione del software da inserire un uno slot USB per il dispositivo di controllo del sistema o dispositivo di controllo del sistema Lite Il dispositivo di controllo del sistema o dispositivo di controllo del sistema Lite pu unicamente funzionare su un PC dotato di chiave Wibu Tuttavia la chiave Wibu non richiesta per il software VRF Explorer da remoto 064 065 Adattatore e convertitore 066 Gateway BACnet UTY ABGX possibile collegare BMS di grandi dimensioni ad un sistema di rete VRF tramite BACnet s standard globale per reti aperte DVD ROM Chiave possibile collegare un massimo di 1600 unit interne con 4 sistemi di rete VRF Software protezione un massimo di 400 unit interne e 100 unit esterne per un sistema di rete ad un gateway software BACnet possibile controllare o monitorare il sistema di rete VRF dal BMS tramite il gateway BACnet Compatibile con il dispositivo di controllo specifico per l applicazione BACnet ANSI ASHRAE 135 2004 B ASC e Compatibile con BACnet IP su Ethernet Le funzioni di programmazione di gestione eventi e allarmi nonch di ripartizione del consumo elettrico sono fornite all interno del gateway BACnet BACneta un marchio fegitrato di ASHRAEDRSHRAE non e I I I i
44. 2 L unit RB non necessaria per l utilizzo della sola modalit di raffreddamento Installazione e manutenzione facilitata Installazione flessibile dell unit RB Altezza 198 mm Il design compatto e ristretto consente di risparmiare spazio Non richiesto il tubo di scarico La posizione del quadro di controllo pu essere cambiata per rispondere alle condizioni di installazione L installazione possibile dall altro L installazione possibile in verticale lato cos da liberare il quadro per l utilizzo in spazi ristretti di controllo Il design compatto consente di risparmiare spazio Non richiesto il tubo di condensa Collegamenti in serie per una installazione facilitata pe 1 Collegamento a 2 vie gt in ica possibile collegare lI in serie fino a 2 unit Unit RB Tipo multiplo Unit RB Tipo singolo Manutenzione facilitata in spazi ristretti L i Le attivit di manutenzione possono essere svolte dal lato Il quadro elettrico accessibile facendo scorrere lo sportello di chiusura Le parti possono essere facilmente posizionate in spazi ristretti nel soffitto Esere gt Unit RB Soffitto 041 Composizione unit esterne Sono sconsigliate composizioni diverse da quelle indicate di seguito Combinazione in funzi
45. 3 11 8 11 2x 2 11 8 11 2x 2 11 8 x 2 11 2 11 8 x 2 11 2 11 8 x 2 11 2 11 8x 3 11 8x 3 11 8 x 3 Diametro linee Liquido 12 70 15 88 15 88 15 88 15 88 19 05 19 05 19 05 19 05 19 05 19 05 19 05 frigorifere Gas iud 28 58 34 92 34 92 34 92 34 92 34 92 34 92 34 92 41 27 41 27 41 27 41 27 Limiti SSS FP da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 operativi ir dl da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 Nota le specifiche si basano alle seguenti condizioni Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Quando l operazione di raffreddamento viene effettuata con una temperatura d aria esterna inferiore a 5 C l unit esterna deve essere installata in una posizione che risulti maggiore o uguale a quella delle unit interne 1 Il numero minimo di unit interne collegabili 2 Tuttavia ARXC72 e ARXC90 possono funzionare anche con una singola unit Quando misurati nello stato effettivo di installazione il rumore circostante e il valore misurato pu essere diverso rispetto al v
46. 5 Alimentazione 3 fasi 4 fili 400 V 50Hz 3 fasi 4 fili 400 V 50Hz Capacit e T kW 44 8 62 4 67 2 72 8 78 3 84 8 89 4 95 9 102 4 113 5 120 0 125 0 mento 37 23 Potenza d ingresso Riscalda kW 35 50 EER ep o WAN 3 36 COP mento 3 94 Portata flusso dell aria Alta m h 11 100 x 2 13 000 11 100 11 100 x 3 11 100 x 3 11 100 x 3 13 000 11 000 x 2 11 100 x 3 13 000 11 100 x 2 13 000 x 2 11 100 13 000 x 2 11 100 13 000 x 3 13 000 x 3 Livello pressione P JB 59 61 61 62 62 63 62 63 64 64 65 65 sonora Riscalda A 62 61 62 63 63 64 64 65 65 66 66 Pressione statica esterna massima Pa 80 80 80 80 80 80 80 80 80 80 80 Potenza nominale compressore kW 3 9x2 3 9x2 4 5 3 9x 3 3 9x 3 3 9x3 4 5 3 9x3 4 5 3 9 x 3 4 5 x 2 3 9x3 4 5x2 3 9x3 45x2 3 9x3 45x3 3 9x3 45x3 3 9x3 45x3 Scambiatore di calore Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Altezza mm 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 Dimensioni Larghezza mm 930 x 2 930 1 240 930 x 3 930 x 3 930 x 3 930 x 2 1 240 930 x 3 930 x 2 1 240 930 1 240 x2 930 1 240 x 2 1 240 x 3 1 240 x 3 Profondit mm 765 765 765 765 765 765 765 765 765 765 765 765 Peso kg 220 220 303 220 220 220 220 220 220 220 275 220 220 303 220 220 275 275 220 303 275 220 303 303 220 303 303 275 303 303 303 303 303 303 Carica refrigerante kg 11 2 x 2 11 8 11 2 11 2x 3 11 2x
47. 80 80 80 80 80 80 80 Potenza nominale compressore kW 3 9 3 9 3 9 4 5 3 9 4 5 3 9 4 5 3 9 x2 39x2 45x2 39x2 45x2B9x2 45x239x2 45x239x2 45x23B9x3 45x239x3 45x339x3 45x3B9x3 45x339x3 45x3B9x3 45x389x3 45x339x3 45x3 Scambiatore di calore Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Altezza mm 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 Dimensioni Larghezza mm 930 930 930 1 240 1 240 930 x 2 930 x 2 930 x 2 930 x 2 930 1 240 930 1 240 1 240x2 1 240 x 2 930 x 3 930x3 930 x2 1 240 930 x 2 1 240 930 1 240 x 2 930 1 2240 x2 1 240 x 3 1 240 x 3 Profondit mm 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 765 Peso kg 220 220 275 303 303 220 220 275 220 275 220 275 275 303 275 303 275 303 303 296 296 275 275 220275 275 275303 275 275803 275 275803 303 275803 303 275303 303 3033303 303 303 Carica refrigerante kg 11 2 11 2 11 8 11 8 11 8 11 2 x 2 11 8 11 2 11 8 11 2 11 8 x 2 11 8 x 2 11 8 x 2 11 8 x 2 11 8x2 11 8x2 11 2 118x3 11 8 x 3 11 8x 3 11 8 x 3 11 8x 3 11 8x 3 11 8x 3 Diametro linee Liquido m 15 88 19 05 19 05 19 05 19 05 19 05 19 05 19 05 19 05 frigorifere Gas 22 22 22 22 28 58 28 58 28 58 28 58 28 58 34 92 34 92 34 92 34 92 34
48. 92 34 92 34 92 41 27 41 27 41 27 41 27 41 27 41 27 41 27 Limiti SS NM da 15a 46 da 15a46 da 15a46 da 15a46 da 15a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 da 5 a 46 operativi Aer d da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20a21 da 20a21 da 20a21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 da 20 a 21 Combinazione in funzione della resa energetica Range di potenza HP 16 22 24 26 28 30 32 34 36 40 42 44 Nome modello AJH144LALHH AJH198LALHH AJH216LALHH AJH234LALHH AJH252LALHH AJH270LALHH AJH288LALHH AJH306LALHH AJH324LALHH AJH360LALHH AJH378LALHH AJH396LALHH Unit 1 AJHA72LALH AJH126LALH AJHA72LALH AJHA90LALH AJH108LALH AJH126LALH AJH108LALH AJH126LALH AJH126LALH AJH126LALH AJH126LALH AJH144LALH Unit 2 AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJH108LALH AJH108LALH AJH126LALH AJH126LALH AJH126LALH AJH126LALH Unit 3 AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJHA72LALH AJH108LALH AJH126LALH AJH126LALH Livello massimo unit interna collegabile 30 33 36 39 42 45 48 48 48 48 48 48 Capacit unit interna collegabile Rafigdda kw 22 4 67 2 31 2 93 6 33 6 100 8 36 4 109 2 39 2 117 4 42 4 127 2 44 7 134 1 48 0 143 8 51 2 153 6 56 8 170 2 60 0 180 0 62 5 187
49. ALH AJH126GALH AJH126GALH AJH126GALH AJH144GALH AJH126GALH AJH144GALH pua AJHA72GALH AJHA72GALH AJHA72GALH AJHA72GALH AJHA90GALH AJHA90GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH AJH126GALH AJHA72GALH AJHA72GALH AJHA72GALH AJHA90GALH AJHA72GALH AJHA90GALH AJHA72GALH AJHA90GALH AJHA90GALH AJH126GALH AJH126GALH Livello massimo unit interna collegabile 24 33 36 39 42 45 48 51 54 57 60 64 64 Capacit unit interna collegabile kW 22 4 67 2 31 2 93 6 33 6 100 8 36 4 109 2 39 2 117 6 42 0 126 0 45 2 135 6 48 0 144 0 51 2 153 6 54 0 162 0 56 5 169 5 60 0 180 0 62 5 187 5 Alimentazione 3 fasi 4 fili 400 V 50Hz 3 fasi 4 fili 400 V 50Hz Capacit Raffredda Da 44 8 62 4 67 2 72 8 78 4 84 0 90 4 96 0 102 4 108 0 113 0 120 0 125 0 AE 50 0 70 0 75 0 81 5 88 0 94 5 101 5 108 0 115 0 121 5 126 5 135 0 140 0 Potenza eio n da 32 06 34 02 36 29 d ingresso Riscalda M 31 00 32 70 34 57 EER Raffredda WIW 3 52 3 53 3 44 COP Riscalda W W 4 08 4 13 4 05 Portata flusso dell aria m h 13 000 11 100 11 100x3 11 100x3 11 100x3 13 000 11 100x2 13 000 11 100x2 13 000x2 11 100 13 000x2 11 100 13 000x3 13 000x3 Livello pressione Pamredda 59 62 64 64 65 65 65 sonora us nid 61 63 65 65 66 66 Pressione statica esterna massima Pa 80 80 80 80 80 80 Potenza in uscita motore kW 11 0 7 5 7 5x3 7 5x3 7 5x3 11 0 7 5x2 11 0 7 5x2 11 0x2 7 5 11 0x2 7 5 11 0x3 11 0x3 Scambiatore di calore Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin
50. Alta visibilit e operazioni facilitate Operazioni con un clic La propriet viene mostrata visivamente dalla prospettiva pi idonea per le operazioni e attivata di conseguenza Operazione con un clic possibile selezionare tra 4 visualizzazioni sito edificio piano o elenco Le propriet possono essere visualizzate Operazioni con un clic sull intero edificio Vista sito Controllo d insieme su gruppi definiti liberamente utilizzando una delle quattro opzioni sito edificio piano o elenco La visualizzazione facilmente intercambiabile premendo il tasto Gruppi definiti liberamente per il controllo sull insieme Le unit interne possono essere liberamente raggruppate per ottenere un controllo facilitato sull insieme grazie al menu ad albero inoltre possibile il raggruppamento per struttura gerarchica ad esempio per sezioni divisioni o reparti Operazioni con un clic per qualsiasi unit specificata wa quer pasaq i x Vista elenco Gestione operazioni diversificate e gestione dei dati Gestione programmi programmi annuali possono essere impostati per ciascun gruppo di dispositivi di controllo remoto gruppo definito dall utente Le funzioni di accensione spegnimento modalit operativa blocco dispositivo di controllo remoto impostazioni temperatura possono essere regolate fino a 143 volte al giorno ad intervalli di 10 minuti per un
51. B Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Canalizzato slim installazione verticale e orizzontale Nome modello ARXDO9GALH ARXD12GALH ARXD14GALH ARXD18GALH ARXD24GALH Alimentazione VIDIHZ 230 1 50 Capacit Raffreddamento kW 1 4 2 2 2 8 3 6 4 5 5 6 7 1 Riscaldamento 1 3 2 8 3 2 4 0 5 0 6 3 8 0 Potenza d ingresso W 40 44 50 54 92 83 122 Portata flusso dell aria Alta 510 550 600 600 800 940 1 330 Media 400 470 490 550 510 710 840 1 240 Bassa 320 440 440 480 450 610 750 1 100 Intervallo pressione statica da 0 a 90 da 0 a 90 da 0 a 90 da 0 a 90 da 0 a 90 Pressione statica standard Pa 25 25 25 25 Livello pressione Alta 26 29 34 35 sonora Media dB A 21 25 26 32 32 Bassa 20 22 24 28 29 Dimensioni A x L x P mm 198 x 700 x 620 198 x 900 x 620 198 x 1 100 x 620 Peso kg 22 26 Diametro linee 09 52 frigorifere mm 015 88 Tubo di scarico VP25 925 D I 932 D E Nota le specifiche si basano sulle condizioni seguenti Canalizzato a media pressione statica Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit e
52. Blue fin Blue fin Blue fin Altezza mm 998 998 998 Dimensioni 970 970 370 370 370 Peso kg 86 87 Diametro linee Liquido mim 29 52 29 52 frigorifere Gas 015 88 215 88 Lunghezza totale del tubo 80 80 80 Dislivello max 30 30 30 Limiti PAU pd ic da 5 a 46 da 5 a 46 da 5 a 46 operativi Riscalda da 20 a 21 da 20 a 21 da 20 a 21 Nota le specifiche si basano alle seguenti condizioni Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m La funzione di protezione funziona quando l utilizzo al di fuori dell intervallo operativo Dimensioni Unit mm Modello AJH040LCLAH AJH045LCLAH AJH054LCLAH 970 Terminal blocks Transmi ssion Terminal blocks Power 3 Way valve Lioii 998 697 608 297 Gas valve Liquid valve Dettaglio A 025 026 Pompa di calore AJHAAOLALH AJHA45LALH AJHASALALH General offre sistemi di aria condizionata per una ampia gamma di applicazioni da piccoli edifici adibiti ad uffici ed esercizi commerciali ad abitazioni domestiche di grandi dimensioni Caratteristiche Caratter
53. GO FUNZIONI Gestione remota per dispositivo di controllo del sistema per dispositivo di controllo del sistema Lite UTY PLGXR1 Dispositivo di controllo del sistema Dispositivo di controllo sistema Lite Funzione Tipo EE EIE Il dispositivo di controllo del sistema pu essere usato presso UTY PEGX UTY PLGXR1 UTY PLGXA1 UTY PLGXE1 il si ie reti i 4 1 Ms pena an a Dispositivo di controllo centralizzato da remoto DETINE Max unit interne gruppi dispositivi di controllo remoto per rete VRF 400 400 2 software Il dis iti di trollo VRF ei 1 VRF Explorer in grado di controllare o monitorare fino a 10 siti Susie Max unit esterne per dispositivo di controllo sistema 100 100 positivo di controllo avora presso Il SITO Max unit interne gruppi dispositivi di controllo remoto per dispositivo di controllo sistema 1600 400 comunica con il sistema VRF L Explorer VRF lavora da remoto Explorer VRF Max unit esterne per dispositivo di controllo sistema 400 100 e contiene l interfaccia utente comunicando con il dispositivo di Visualizzazione siti multipli 10 o 10 controllo VRF Controller VRF Numero di edifici 1 sito 20 Societ gestione fabbriche centri di gestione ecc N Numero di piani per 1 sito Numero di piani per 1 edificio a Vista layout grafico 3D Vista layout grafico 2D Visualizzazione elenco Il programma VRF Con
54. ID MUN ALS bm mee Ii re TL LTD ALT SL TC Per tipo a cassetta Flangia quadrata UTD SF045T Per tipo canalizzato pressione statica media Kit griglia chiusura automatica UTD GXSA W per ARXD04 07 09 12 14GALH UTD GXSB W per ARXD18GALH UTD GXSC W per ARXD24GALH Per tipo tubo sottile EE Unit sensore remoto UTY XSZX Per tutti i canalizzati possibile offrire un ulteriore spazio di servizio installando il sensore remoto Unit pompa di scarico UTZ PX1BBA Per tipo canalizzato pressione statica bassa UTZ PX1NBA Per tipo canalizzato pressione statica media Unit interna Unit esterna remoto centrale Operazione blocco UTY xwzxzD _ O UTY XWZXZB UTv xwzxz7 Tutto acceso tutto spento P Q UTY XWZXZ8 Blocco dell insieme UTv xwzxze n Blocco forzato UTY xwzxzD O UTY XWZXZB UTY XWZXZD UTY XWZXZ7 Dispositivo di controllo Dispositivo di controllo con pannello touch Unit RB Kit presa aria esterna UTZ VXAA UTZ VXGA Per tipo a cassetta Per tipo a cassetta compatto Pannello chiusura meccanica uscita aria UTR YDZB Per tipo a cassetta compatta 60x60 Chiude un uscita aria quando si vogliono usare solo 3 uscite Pannello chiusura meccanica uscita aria UTR YDZC Per tipo a cassetta 900x900 Chiude un uscita aria quando si vogliono usare solo 3 uscite emm
55. SO 14001 Filiali per la vendita 3 Filiali per la produzione 5 Ciascun centro di produzione estero 5 aziende ha singolarmente portato a termine la procedura di certificazione in conformit alle normative ISO 9001 e ISO 14001 Nel 2012 i centri di vendita esteri 11 aziende hanno acquisito la certificazione ISO 14001 Europa MI Filiali per la vendita 3 Nord America W Filiali per la vendita 1 Medio Oriente MI Filiali per la vendita 1 Sud America W Filiali per la vendita 1 BEISO9001 MI ISO014001 Ispezione RoHS Ispezione visiva sulle parti Ispezione specifiche delle parti Ispezione visiva sul gruppo T Ispezione visiva completa sul prodotto Giappone Sede centrale Filiali per la produzione 2 Oceania W Filiali per la vendita 2 Numero di aziende General offre una ampia gamma di prodotti e di informazioni tecniche a ingegneri e consulenti oltre a svolgere attivit di consulenza sui sistemi VRF L azienda offre servizi di consulenza cos da garantire la massima qualit costante dalla progettazione all installazione L am s f y j s de E a Nn 008 Informazioni tecniche L azienda offre una serie di informazioni e strumenti utili per la progettazione di sistemi di condizionamento dell aria tra cui tool e dati sulle prestazioni delle unit che facilitano le preventivazioni e selezioni dei var
56. TH ARXC60GATH ARXC72GATH ARXC90GATH Alimentazione VIDIHZ 230 1 50 Capacit Raffreddamento kW 11 2 12 5 18 0 22 4 25 0 Riscaldamento 12 5 14 0 20 0 25 0 28 0 Potenza d ingresso W 405 715 730 1 110 1 250 Portata flusso dell aria Alta 2 600 3 500 3 500 3 900 4 300 Media m3 h 1 950 3 000 3 000 3 300 4 000 Bassa 1 450 2 460 2 460 3 000 3 500 Intervallo pressione statica da 100 a 200 da 100 a 250 da 100 a 250 da 50 a 300 da 100 a 300 Pressione statica standard Pa 100 100 100 260 250 Livello pressione Alta 45 49 49 51 53 sonora Media dB A 38 45 45 48 51 Bassa 32 42 42 45 49 Dimensioni A x L x P mm 400 x 1 050 x 500 450 x 1 550 x 700 Peso kg 43 46 83 85 Diametio ince Liquido 29 52 Combustione 12 70 Brasatura frigorifere Gas mm 19 05 Combustione 22 22 Brasatura Tubo di scarico VP25 925 D l 932 D E Nota le specifiche si basano sulle condizioni seguenti modelli ARXC60 72 90LATH non sono collegabili alla serie J Il Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Pavimento Soffitto IW Nome modello ABHA12GATH ABHA14GATH ABHA18GATH ABHA24GATH Alimentazione V Hz 230 1 50 Capacit Raffreddamento 56 A Ri
57. U K CO LIMITED FG EUROFRED LIMITED WAVE AIR CONDITIONING LIMITED FUJITSU GENERAL EURO GmbH ue wm ay e FUJITSU GENERAL MEDIO ORIENTE FZE e FUJITSU GENERAL CENTRAL AIR CONDITIONER WUXI CO LTD e EG L S ELECTRIC CO LTD y P2 B F We FUJITSU GENERAL LIMITED FUJITSU GENERAL ORIENT INTERNATIONAL ELECTRONICS SALES SHANGHAI CO LTD FUJITSU GENERAL SHANGHAI CO LTD FUJITSU GENERAL TAIWAN CO LTD FUJITSU GENERAL AUST PTY LIMITED FUJITSU GENERAL NEW ZEALAND LIMITED FUJITSU GENERAL ASIA PTE LTD FUJITSU GENERAL TAILANDIA CO LTD FUJITSU GENERAL ENGINEERING TAILANDIA CO LTD FGA TAILANDIA CO LTD TCFG COMPRESSOR TAILANDIA CO LTD Alta qualit degli ambienti di progettazione e produzione di alta qualit Sede centrale GIAPPONE Centro ricerca e sviluppo e torre di collaudo di altezza 60 m Fujitsu General Shanghai Co Ltd Fujitsu General Central Air conditioner Wuxi Co Ltd FGA Tailandia Co Ltd F G L S Electric Co Ltd 1 sf rmm M eem Il Fujitsu General Tailandia Co Ltd Fujitsu General Engineering Tailandia Co Ltd TCFG Compressor Tailandia Co Ltd STORIA AZIENDALE La nostra Storia s s TT ER a __ ____ em Azienda impegnata nella produzione di soluzioni di condizionamento dell aria dal 1971 con diffusione su scala mondiale
58. UNIT AJHA90 A72 A72LALH UNIT AJH108 A72 A72LALH 84 8 KW 30HP 89 8 KW 32HP 95 9 KW 34HP 102 4 KW 36HP 113 5 KW 40HP ea lt lt a wa ES Tia c5 AJH270LALHH AJH288LALHH AJH306LALHH AJH324LALHH J AJH360LALHH UNIT AJH126 A72 A72LALH UNIT AJH108 108 A72LALH UNIT AJH126 108 A72LALH UNIT AJH126 126 A72LALH UNIT AJH126 126 108LALH 120 0 kW 42HP 125 0 KW 44HP AJH378LALHH AJH396LALHH UNIT AJH126 126 126LALH UNIT AJH144 126 126LALH 034 14 16HP AJH126LALH AJH144LALH 8 10 12HP AJHA72LALH AJHA90LALH AJH108LALH 690 Passo del bullone 80 530 Passo J bullone A 8 12 x 17 Foro 732 Passo del bullone 1576 1000 Passo del bullone 1690 t ti TTT 840 Passo del bullone 732 Passo del LA Posizione separatore lato frontale D 34 5 43 7 Porta cavo alimentazione Porta cavo 22 2 alimentazione 22 2 Porta cavo alimentazione Porta cavo trasmissione Porta cavo trasmissione D Posizione separatore lato sinistro 50 Porta cavo alimentazione 22 2 Porta cavo trasmissione Posizione separatore lato inferiore Vista dall
59. Unit RB Tipo Tipo singolo Tipo multiplo Nome modello UTP RX01 AH UTP RX01BH UTP RX01CH UTP RX04BH Alimentazione VIDIHZ 230 1 50 Potenza d ingresso W 96 Numero diramazioni 4 Capacit massima delle unit interne collegabili Q Capacit massima delle unit interne collegabili per diramazione Q kW Q 56 0 1 kW Q lt 18 0 Numero massimo delle unit interne collegabili per diramazione Dimensioni AxLxP mm 198x298x268 260x658x428 3 8 8 8 1 In caso di due unit RB collegate in serie totale 8 diramazioni la capacit massima di unit interne collegabili raggiunge i 56 0 kW 075 Dispositivi di controllo Per controllo individuale Dispositivo di controllo con filo Dispositivo di controllo con filo Dispositivo di controllo semplice Pannello touch UTY RLRG UTY RSKG UTY RNRG Con modalit operazioni Dispositivo di controllo semplice Dispositivo di controllo wireless Unit ricevitore IR UTY RHKG UTY LNHG UTB YWC Senza modalit operazioni C Per tutti i tipi di canalizzati Unit ricevitore IR UTY LRHGB1 Per tipo a cassetta Per controllo centralizzato Dispositivo di controllo remoto Dispositivo di controllo con pannello Dispositivo di controllo remoto per gruppo centrale touch UTY CGGG UTY DCGG UTY DTGG Dispositivo di controllo Dispositivo di sistema Lite controllo sistema
60. aborazione di progetti e layout altamente affidabili E So ue s Informazioni sull installazione Le altre informazioni tra cui i simboli che indicano la direzione del flusso d aria necessarie per essere inserite negli elaborati grafici di installazione vengono elaborate e possono essere automaticamente applicate negli elaborati grafici 2D Gli elaborati grafici sull installazione possono essere creati con la massima facilit amp ille Depth 350 mm Specifiche prodotti informazioni e link Contiene le informazioni di base necessarie per la progettazione dei condizionatori d aria tra cui dimensioni dell unit capacit alimentazione in ingresso rumore tasso flusso d aria 011 General desidera garantire un servizio sempre rapido di manutenzione e riparazione In caso di problemi ad una unit o sistema sono disponibili numerosi strumenti tra cui un display di visualizzazione del codice di errore sul prodotto un Service Tool che consente di verificare in dettaglio lo stato dell intero sistema un tool per il monitoraggio a distanza che utilizza Internet ecc In questo modo possibile garantire un servizio sempre rapido di manutenzione e riparazione in qualsiasi momento e dovunque Progettazione per una facile manutenzione Lo stato operativo del condizionatore d aria e lo stato dettagliato dei guasti vengono visualizzati sul 7 segmento della PCB unit esterna o sullo schermo del dispositivo di
61. affrontabili Anche quando viene installata su un balcone adattabile all altezza del parapetto La dimensione compatta con altezza inferiore a 1 m consente di installare l unit sotto le finestre e in spazi ristretti Modello classe 6HP Differenza di altezza 996 mm A 25 Peso leggero 87 kg A 26 Basso livello sonoro Raffreddamento dB A 53 51 4 HP 5 HP Grande ventola assiale Prestazioni elevate e livelli ridotti di rumore grazie alla grande ventola assiale e all ottimizzazione dell angolo di inclinazione delle pale Motore ventola DC Il motore del ventola a bassa emissione sonora garantisce prestazioni elevate e molteplici stadi di velocit Scambiatore di calore di grandi dimensioni Le prestazioni dello scambiatore di calore risultano considerevolmente potenziate con il montaggio di uno scambiatore di calore grande a 3 tubi Trasferimento di calore elevato con tubo in rame angolo di spostamento migliorato Il livello sonoro considerevolmente basso viene migliorato grazie al compressore rotativo Twin DC alla tecnologia a inverter e alla progettazione strutturale avanzata relativa al flusso dell aria In modalit riduzione rumore possibile impostare un 56 livello di emissione sonora minore rispetto a 54 nominale basso 6 HP 6 HP ARsTAGE J IS Modello precedente Tecnologia d avanguardia ad elevata efficienza ku QT T Grigl
62. alore indicato 2 Il valore sonoro corrisponde al valore misurato in una camera anecoica 037 038 Recupero calore Design d avanguardia e intelligente Composizione ampia con incremento da 8HP a 48HP Livello capacit unit interne collegabili fino a 150 della potenza delle unit esterne Caratteristiche 8 10 12HP 14 16HP Caratteristiche Alta efficienza Funzionamento effettivo ad alta efficienza IICOP elevato di alta classe viene ottenuto per tutte le combinazioni tramite la nostra struttura esclusiva di scambiatori di calore compressore Twin DC ad alta efficienza e tutte le altre tecnologie aziendali Composizione per risparmio dello spazio COP 5 4 39 430 vr 4 34 430 4 390 3 92 07 390 405 391 401 392 401 390 400 394 400 391 3 98 3 92 3 2 1 0 8 10 12 14 16 18 20 22 24 26 28 30 32 34 Composizione ad efficienza energetica COP 5 499 422 995 435 432 430 424 423 4148 447 408 4 13 m 16 22 24 26 28 30 32 34 36 38 40 42 44 HP 36 38 40 42 44 46 48 HP Per composizione 24 HP Riduzione spazio Efficienza energetica ej gt tea COP 12 6 IN PI Tecnologia di risparmio energetico che potenzia l efficienza del sistema Ventola assiale grande e potente Grazie alla tecnologia CFD la ventola di nuova progettazione raggiunge prestazioni elevate e un funzionamento con livelli ridot
63. ario 4 in modo altamente flessibile Temperatura ambiente Programma 1 Programma estate Programma 2 Programma inverno e Lo spegnimento automatico pu essere impostato tra i 30 e i 240 minuti a 7 3 Multi lingue e e O o amp 26 C LCD S sui SPENTO SPENTO i T i g I g O Pasa Ora legale o E i E e e EB y raa asc i A i N N i i s E Registrazione nome O a i o e e e Impostazione fascia oraria dalle 17 00 alle 24 00 2 m i i HEN i Retroillluminazione o o o o e SPEGNIMENTO 8 40 11 40 17 30 2040 7 8 40 10 00 15 30 17 30 20 40 ACCESO SPENTO i ACCESO automatico ACCE Tenno Tempo Layout piano 2D Visual edificio 3D E _ u _ _ EA _ z v P Periodo Settimana Settimana Settimana Settimana Anno Anno Anno Programmazione Acceso Spento Orario normale Orang straordi Ritorno automatico Impostazione temperatura Wer Li Ph i 1 H H 4 ci a 144 DE 8 17 24 La temperatura impostata ritorna automaticamente alla temperatura Es In corrispondenza dell ora della fascia impostata dalle 17 00 alle 24 00 impostata n precedenza La fascia oraria in cui la temperatura impostata Timer acceso spento e o e per evitare di dimenticarsi di spegnere pu essere modificata compresa tra 10 e 120 minuti 2 Timer veglia _ i u u _ _ _ _ _ Tempo impostato per lo spegniment
64. armio della capacit dell unit esterna consente di La porta Ethernet richiesta per il collegamento da remoto utilizzando ruotate all interno di un gruppo in base al programma annuale impostato selezionare il limite superiore di capacit dell unit esterna per eliminare Acceleratore Microsoft DirectX 9 0c compatibile cos da ridurre il consumo di energia pur mantenendo il massimo comfort il consumo elettrico durante le estati molto calde e gli inverni molto freddi Software Adobe Reader 9 0 o successivo Inoltre possibile selezionare il livello di blocco delle operazioni dell unit ottenendo una media dell effetto del risparmio energetico su ciascun sistema Unit ottica DVD ROM drive interna refrigerante E possibile selezionare dal 50 in poi di limite superiore della capacit Il PC deve essere fornito su campo x dii L interfaccia di rete U10 USB deve essere fornita su campo Contattare Echelon Corporation o i suoi rappresentanti locali per ulteriori informazioni Calde 22 B UENIT Nome prodotto Interfaccia rete UTO USB TP FT 10 canali Numero modello 75010R giomate ne za ELENCO IMBALLAGGIO Suus Per dispositivo di controllo sistema Per dispositivo di controllo sistema zm Tipo Dispositivo di noq dira N o controllo del sistema Gestione energia sistema Lite Accesso remoto Distribuzione rete elettrica Risparmio energetico d inverno Nome modello UTY APGX UTY PEGX UTY ALGX UTY PLGXR1 UTY PLGXA
65. assimo di capacit dell unit interna collegabile del 110 L installazione in condizioni di temperatura estrema possibile grazie all aumento dell intervallo operativo AIRSTAGE Serie J IIS Tipo pompa di calore AIRSTAGE Serie V II Tipo pompa di calore C Raffreddamento C Raffreddamento SL 46 C ie 46 C 40 40 30 Riscaldamento 30 Riscaldamento 2 21 C a 21 C 10 10 O O 10 10 20 20 20 C 20 C AIRSTAGE Serie J Il Tipo pompa di calore AIRSTAGE Serie VR II Tipo recupero di calore EE Raffreddamento C Raffreddamento 50 46 C 50 46 C 40 40 Raffreddamento 30 Riscaldamento 30 e riscaldamento Riscaldamento d 21 C 7 21 C 21 C 10 10 O O 10 10 20 20 10 C 20 C 20 C 018 4 Nota quando viene utilizzato un collegamento dell unit esterna multiplo l intervallo operativo compreso tra 5 C e 46 C in modalit raffreddamento Alta affidabilit Protezione da ritorno del liquido Nell adottare un accumulatore di grandi dimensioni il refrigerante non completamente vaporizzato rimane all interno dell accumulatore per garantire che non vi sia refrigerante alimentato nel compressore Refrigerante completamente vaporizzato lt Dall evaporatore Refrigerante liquido rimane all interno dell accumulatore Accumulatore Compressore di grandi dimensioni Prolungamento della vita dei compressori Adozione dello scambiatore
66. ate a display E possibile visualizzare i numeri di indirizzo impostati in duplicato per le unit interne Range di potenza HP 4 5 6 Nome modello AJHA45LALH AJHA54LALH Livello massimo unit interna collegabile 7 8 9 Alimentazione VIQDIHZ 230 1 50 230 1 50 230 1 50 Capacit meno n kW T r 12 RES 6 0 18 0 aaa dde 3 25 3 89 4 49 Alimentazione d ingresso Riscalda kW 3 17 3 81 4 56 EER Rete w 3 60 3 45 COP mena 4 29 4 20 3 95 Portata flusso d aria ms h 6 200 6 400 6 900 Livello pressione memo dB 50 51 53 sonora Riscalda A 52 53 55 Scambiatore di calore Blue fin Blue fin Blue fin Altezza mm 1 334 1 334 1 334 Dimensioni 970 970 370 370 370 Peso kg 117 117 Carica refrigerante kg 5 3 5 3 Diametro linee Liquido 99 52 99 52 frigorifere Gas 015 88 219 05 Diametro linee igo da da 5 a 46 da 5 a 46 frigorifere A cdd da 20 a 21 da 20 a 21 da 20 a 21 Nota le specifiche si basano alle seguenti condizioni Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m La funzione di protezione funziona quando l utilizzo al di fuori dell intervallo operativo Dimensioni Unit mm Modello AJHA40LALH AJHA45LALH AJHASALALH
67. atte stata ridotta considerevolmente la larghezza delle unit esterne a confronto con i modelli precedenti c a Serie V Serie V II Serie V Serie V II 10HP 10HP 16HP 8HP x2 16HP 28 riduzione riduzione 1 300 mm 2 600 mm 1 240 mm Tecnologia di risparmio energetico che potenzia l efficienza del Sistema Ventola assiale grande e potente Grazie alla tecnologia CFD la ventola di nuova progettazione raggiunge prestazioni elevate e un funzionamento con livelli ridotti di rumore ur m a d 1 CFD Fluidodinamica computazionale Motore ventola DC Il consumo energetico stato ridotto di un 25 a confronto con i modelli precedenti utilizzando un motore a ventola DC compatto e ad alte prestazioni Scambiatore di calore sottoraffreddamento L elevata efficienza dello scambiatore di calore ottenuta utilizzando una struttura interna con doppi tubi Controllo inverter DC a onda sinusoidale Le operazioni ad alta efficienza vengono realizzate utilizzando un dispositivo di controllo inverter CC a onda sinusoidale Compressore rotativo Twin DC La considerevole maggior efficienza viene ottenuta con l utilizzo di un compressore rotativo Twin DC di grande capacit con assunzione sostanzialmente maggiore di refrigerante e alta efficienza di compressione Scambiatore di calore a 4 lati L efficienza dello scambiatore di calore risulta considere
68. atteria 1 5 V R03 LR03 AAA x 2 CC 12V CC 12V Dimensions H x W x D mm 170 x 56 x 19 145 x 90 x 30 193 9 x 193 9 x 31 2 Peso g 85 150 140 La DC 12 V viene erogata dall unit interna Num max controllabile per gruppo V In un sistema di rete VRF Dispositivo di controllo remoto per gruppi UTY CGGG Controllo sul gruppo di unit interne con una semplice operazione Num max controllabile 8 gruppi di dispositivi di controllo remoto possibile controllare fino a 8 gruppi di dispositivi di controllo remoto con un solo dispositivo di controllo ALE IAUT a remoto per gruppi possibile collegare fino a 64 dispositivi di controllo remoto per gruppo all interno di un sistema di rete VRF ell convertitore di rete necessario per poter collegare i dispositivi di controllo remoto per gruppi al sistema di rete VRF Il convertitore di rete consente l impiego di max 4 dispositivi di controllo remoto per gruppi Tipo a 3 fili Controllo fino a 8 gruppi di dispositivi di controllo remoto ell singolo dispositivo di controllo remoto per gruppi controlla e monitora fino a 8 gruppi di dispositivi di controllo remoto Refrigerante sistema 1 Refrigerante sistema 2 Li Ln SN l Sala conferenze o Convertitore Dispositivo
69. ca E allarme antincendio Dispositivo di Unita interna Split controllo con filo Attacco E finestre Interfaccia MODBUSMODBUS FJ RC MBS 1 m anisa di L interfaccia MODBUS consente la totale integrazione dei climatizzatori d aria alla rete MODBUS Installazione facilitata grazie alle dimensioni piccole e compatte cune uma E o6 nan Non richiesta l alimentazione esterna autonoma uu L interfaccia MODBUS permette il monitoraggio centrale e il controllo dei condizionatori d aria da BMS Max 63 Interfaccia MODBUS L interfaccia MODBUS pu essere usata con Rete MODBUS tt eelllu o senza il dispositivo di controllo remoto con filo BMS E i u i Dispositivo w di controllo kL l centrale wana Unit interna VRF NECI I i mari La Hn i sie dl E i Unit interna VRF NN E z En cs Dispositivo di Unit interna Split UE BURN sm w m mim NAM s controllo con filo Specifiche Nome modello FJ RC MBS 1 Nome modello FJ RC KNX 1i Dimensioni A x L x P mm 93x53x58 Dimensioni A x L x P mm 70x70x28 Peso g 85 Peso g 70 068 Interfaccia LAN wireless FJ RC WIFI 1 IntesisHome Si tratta della soluzione pi avanzata per la gestione da remoto di un sistema di aria condizionata utilizzando tutti i tipi di dispositivi mobili tra cui Smartphones Tablets e PC Non
70. cnologia d avanguardia 16 6 Modello attuale classe 6HP 0 7 Temperatura esterna C Ventola assiale Controllo inverter DC Prestazioni elevate e livelli ridotti di rumore grazie alla ventola assiale grande e all ottimizzazione dell angolo di inclinazione delle pale L efficienza migliorata grazie al montaggio di un nuovo modulo del filtro attivo Motore ventola DC Il motore ventola DC produce bassi livelli Py TE di rumore garantisce prestazioni elevate m fce 2 24 ed multi funzione F Scambiatore di calore sottoraffreddamento Le prestazioni di raffreddamento risultano migliori grazie al montaggio di uno scambiatore di calore a tubo doppio ej MEZ E lt p Scambiatore di calore di grandi dimensioni m w w r i o m om ME Le prestazioni dello scambiatore di LIII EO aspa calore risultano considerevolmente A potenziate con il montaggio di uno i scambiatore di calore grande a 3 tubi Entalpia Compressore rotativo Twin DC L efficienza in tutte le situazioni di carico buona Prestazioni particolarmente soddisfacenti sopratutto in funzionamento nominale o a carichi medio bassi T Compressore rotativo Twin DC Motore compressore ad alta efficienza Design flusso refrigerante ottimizzato gt s Parti ad alta precisione o s O o o O a oi E O O Efficienza Capacit compressore Sla 027 Caratteristiche S
71. controllo remoto Lo stato dell unit pu essere rapidamente controllato ed altres possibile ottenere una risposta in tempi rapidi Stato modalit operativa Dispositivo di controllo con filo Pannello touch Dispositivo di controllo con filo Stato errore Cronologia errore Numero sistema Temperatura di scarico Stato pressione 001 Dispositivo di En History I nag controllo 002 Unit interna Codice errore e Indicazione operazioni compressore Indirizzo Tipo Numero dell unit esterna Numero unit Codice errore Tool per la risoluzione di problemi per iPhone Lanceremo una App con un tool per la risoluzione dei problemi da installare su iPhone iPod touch e altri prodotti Apple Bara isa AMATI ILA Indiaer Uni HER Temperature Ganen Li APREA TA Questa applicazione un tool per la risoluzione di problemi dedicato ai condizionatori d aria GENERAL RAC PAC VRF Si tratta di un valido aiuto per il controllo delle condizioni del condizionatore d aria Sono disponibili le funzioni di controllo del codice di errore di risoluzione dei problemi e di controllo del sensore 012 Strumento di monitoraggio per Fornita su campo la manutenzione e riparazione UTY ASSX Scatola comunicazione e software Tubatura refrigerante VD c 9 o 2 UM Em Unit interna zz 5 Fornita su campo S Service T
72. d intervallo blocco unit esterna Consumo elettrico target Microsoft Windows 7 Home Premium 32 bit o 64 bit SP1 Windows 7 Professional 32 bit o 64 bit SP1 controllare possono f f Microsoft Windows 8 32 bit o 64 bit Windows 9 8 Pro 32 bit o 64 bit essere raggruppate Sistema operativo e Microsoft Windows 8 1 32 bit o 64 bit Windows 9 8 1 Pro 32 bit o 64 bit Dati risparmio energetico su grafico Questo grafico confronta il consumo di elettricit con il mese precedente Lingue supportate liberamente ed possibile Inglese cinese francese tedesco russo spagnolo polacco impostare il livello e l anno precedente per facilitare di controllo Linea di controllo CPU Intel Core i3 2 GHz o successivo l analisi dell effetto di risparmio ideale uso del Memoria Per Windows Vista e Windows i 32 bit 2 GB o successivo energetico NP petra AE EEAO EEr ma energetico e Wi dow 7 64 bit Windows 8 e Windows 8 1 4 GB o successivo PA HE HDD spazio libero maggiore o uguale a 40 GB Mostra le modifiche del consumo energetico in base all ora Display Risoluzione maggiore o uguale a 1024 x 768 La porta USB necessaria per ciascuno dei seguenti PC server Operazione rotazione unit interna Risparmio capacit unit esterna Interfaccia N A E sus Le operazioni delle unit interne possono essere automaticamente La funzione di risp
73. di controllo remoto per gruppi 1 Per controllare le stanze adibite ad uffici l area conferenze il ristorante e la hall 8 gruppi di dispositivi di controllo remoto Dispositivo di controllo remoto per gruppi 2 per controllare la stanza degli ospiti e sala conferenze 7 gruppi di dispositivi di controllo remoto Dispositivo di controllo remoto per gruppo Alte prestazioni e dimensioni compatte Le impostazioni ACCENSIONE SPEGNIMENTO Modalit operativa Temperatura in ambiente e Velocit ventola possono essere controllate monitorate a livello centrale o individuale Timer settimanali integrati Il timer settimanale viene fornito come funzione standard 1 Il timer pu essere impostato fino a 4 volte al giorno Accensione Spegnimento modalit operativa impostazione temperatura Controll Controllo T 2 Consente di effettuare le impostazioni distinte per ciascun giorno on ip A ACCESO TL a della settimana centrale SPENTO Specifiche Nome modello UTY CGGG Alimentazione elettrica CC 12V Dimensioni A x L x P mm 120 x 120 x 18 Peso g 200 La DC12 V viene erogata dall unit interna 059 Dispositivi di controllo Num max Num max controllabile controllabile Dispositivo di controllo remoto centrale UTY DCGG M Unit interne Dispositivo di controllo con pannello touch UTY DTGG Unit interne Il dispositivo di controllo remoto centrale adatto per condomini ed edifici Mss s
74. e del 0 5 C per ottenere una temperatura gradevole Funzionamento silenzioso Le due modalit a bassa pressione sonora o priorit capacit sono automaticamente selezionabili tramite l impostazione della priorit silenzioso e l impostazione della priorit di capacit in base all ambiente interno e al carico di temperatura esterna Questa funzione controllabile tramite l ingresso esterno dell unit esterna e o tramite il dispositivo di controllo del sistema Impostazione priorit silenzioso Fattore di carico climatizzazione Carico di calore 100 n Capacit i gi 0 Funzionamento 58 dB con emissione sonora 0 tempo Modalit rumore baso priorit capacit Impostazione capacit prioritaria Condizionamento dell aria fattore di carico Carico di calore Capacit 1908 Alternanza automatica 0 Funzionamento 58 dB wwuunumunnunuunnunuanun con emissione sonora 0 I Reimpostaz automatica tempo Modalit rumore baso priorit capacit Alta Bassa Raggiunge rapidamente la temperatura impostata Funzione di cambio automatico In modalit di impostazione automatica la modalit di raffreddamento riscaldamento viene automaticamente selezionata in base alla temperatura impostata e alla temperatura ambiente 2 C 0 5 C Imposta temp 0 5 C 2 C Tempo 5 Funzion raffredd 342223 Funzion ventola
75. e del limite superiore e inferiore della temperatura Reimpostazione segni filtri Funzionamento memoria Funzionamento modelli Altro L Programma annuale Impostazione giornata speciale Accensione spegnimento per giornata linea pubblica Programma Accensione spegnimento per settimana 504 del telefono o LAN Giornata di ferie Controller VRF Impostazione unit minima del timer Minuti Modalit rumori ridotti Programma settimanale Explorer VRF Gestione Monitoraggio remoto Explorer VRF Controllo operazioni da remoto remota Ri Impostazione funzioni da remoto I Societ di vigilanza i Calcolo bolletta consumo elettricit A m Impostazione condomini m p Impostazione distribuzione spazi comuni Impostazione ripartizione consumo elettrico Societ gestione edifici B Incaricata del turno notturno O O dia uas bh l N NI N Internet o Us I Wu 2 a i BILI o0 IIT pope unen ALI T y D E LEIT Distribuzione rete l z Eu Li I DI j IU i4 ARI E lt re I ru Centro gestione sedi centrali ms Schermo speciale di monitoraggio dettagliato sulle dmm elettrica A ape ato Contatore elettrico supportato Rotazione unit interna Controllo riduzione dei picchi Gestione Risparmio capacit unit e
76. entire una pressione statica esterna di 80 Pa Essa all incirca 2 6 volte pi grande rispetto al modello precedente 032 Maggiore comfort Funzionamento continuo durante il recupero dell olio Una condizione confortevole in ambiente viene mantenuta durante la modalit di recupero dell olio in quanto il prodotto continua ad operare senza dover arrestare le operazioni di raffreddamento o riscaldamento Modello precedente Serie V II Funzione di riscaldamento Funzionamento continuativo durante il recupero dell olio ACCESO ACCESO SPENTO Tempo Manutenzione e riparazione facilitata La manutenzione di componenti elettrici valvole Funzionamento attivo durante la manutenzione e altre parti del compressore tutta agibile dalla parte anteriore del compressore Pannello frontale separato Durante le procedure di riparazione di una unit interna specifica la manutenzione pu essere Il pannello frontale separato svolta anche senza dover spegnere le altre unit interne consente di effettuare la manutenzione nella zona superiore o inferiore dell unit esterna Nota Non disponibile per la serie VR II e serie J Il Unit esterna 00 e Tz Ux fai Unit interna ACCESO SPENTO ACCESO ACCESO ACCESO ACCESO 033 Composizione unit esterne Sono sconsigliate composizioni diverse da
77. ersi al distributore per il condizionatore d aria di tipo split collegabile possibile collegare fino a 100 d convertitori di rete in un sistema di rete VRF singolo Un convertitore di rete singolo viene considerato come ca Soluzione multipla grande sistema refrigerante singolo a prescindere del numero di modelli singoli collegati eLa lunghezza della linea di trasmissione pu essere estesa fino a 3 600m con amplificatori di segnale multipli possibile installare fino a 8 amplificatori di segnali nel sistema di rete VRF richiesto un amplificatore di segnale 1 quando la lunghezza totale dei fili della linea di trasmissione supera i 500 m 2 quando il numero totale delle unit sulla linea di trasmissione supera le 64 Soluzione utilizzata per il collegamento di un dispositivo di controllo remoto per gruppi possibile collegare 4 dispositivi di controllo remoto per gruppi ad un singolo convertitore di rete Convertitore di rete Esempio di installazione Dispositivo di controllo remoto gruppi LT 2 circuiti refrigeranti possono essere inclusi in un convertitore di rete singolo I E possibile collegare fino ad un totale di 16 convertitori di rete e gli adattatori A gt T C 4 Sistema di del dispositivo di controllo remoto centralizzato in un s
78. et di erogazione dell energia elettrica V figura a destra Il calcolo dettagliato tiene in considerazione gli aspetti tra cui le stanze inutilizzate e l elettricit erogata durante la notte queste voci vengono riportate nel foglio di calcolo sul consumo elettrico Esempio di configurazione di sistema x7 AE Societ Energia elettrica condizionamento dell aria lia Unit RB Linea trasmissione segnale Dispositivo di controllo del sistema Scheda distribuzione Condomino A 1 elettrica Scheda distribuzione Unit esterna elettrica l i i per il dispositivo di controllo del sistema e il dispositivo di controllo del sistema Lite Visualizzazione errori e notifiche via e mail L errore viene notificato con un messaggio di popup con un segnale sonore e una e mail inviata in tempo reale non appena si verifica l errore Gli errori per l intero anno precedente sono registrati e possono essere consultati in un secondo momento Visualizza la cronologia dello stato operativo e del controllo Importazione esportazione del database Importa esporta i dati di registrazione i A dati di layout i dati sulle immagini L amministratore il solo a poter utilizzare questa impostazione Regolazione automatica dell orologio L ora su ciascun dispositivo di controllo pu essere impostata automaticamente sul gruppo
79. hi 1 1 1 garantisce approva o collauda i prodotti per verificare la Il collegamento tra il sistema di rete VRF ad un PC possibile tramite una interfaccia piccola ns p RTT NU NER US U10 USB Tuttavia sia l interfaccia U10 USB sia il PC devono essere forniti su campo indicati nei requisiti dello standard ASHRAE 135 sar di 7 m 3 J responsabilit di BACnet International BTL un marchio Disponibile in 7 diverse lingue inglese cinese francese tedesco spagnolo russo polacco registrato di BACnet International Esempio di installazione Operatore BACnet Workstation Sistema di rete VRF 1 BACnet Unit RB I Adattatore USB 1 rm non incluso Unit interna esterna ze l 0500 RB Unit Adattatore USB L antincendio Gateway BACnet Unit esterna ium E Adattatore USB EHI x non incluso m DVD ROM Chiave Adattatore USB Software protezione software mm Cavo USB non incluso Unit interna maaa Ethernet Max 4 sistemi di rete VRF erne UTY ABGX f _ E e nna Sistema ventilazione inea trasmissione Rete VRF Num max controllabile 4 sistemi di rete VRF Num max controllabile 400 Unit esterne Num max controllabile 1 600 Unit interne
80. i di file standard per il settore industriale cmi Ends ens Formato Word rtf mi EE gz E d mm Formato Excel csv i 1 T o Formato Auto CAD DXF i s Dati 2D DXF a Dati 3D RFA n Richieste di informazioni sugli ultimi aggiornamenti Aggiornamenti del simulatore di in ordine cronologico progettazione B i _ Mb L Invio delle informazioni Il database pu facilmente essere aggiornato online sugli ultimi aggiornamenti in ordine cronologico Lato utente PC Lato server FTP PC 010 GENENRAL offre i contenuti e i Modelli di informazioni dell edificio BIM per i sistemi VRF e per alcuni altri prodotti ad architetti progettisti e fornitori che si avvalgono della tecnologia Autodesk Revit dal nostro sito web dal sito web Autodesk Seek ecc Dati prodotti 3D e 2D Offriamo dati 3D che ricreano in modo altamente verosimile l aspetto del prodotto Sono inoltre supportate le progettazioni CD 2D ed J inoltre disponibile il display 2D I dati possono altres essere prodotti N in altri formati tra cui DXF e DWG i quali vengono utilizzati da altri CAD di progettazione Limitazioni installazione se R L intervallo di limitazione per l installazione dell impianto viene altres mostrato requisiti di installazione tra cui la distanza dalla parete vengono automaticamente visualizzati per facilitare l el
81. i modelli Caratteristiche Manuale tecnico e di progettazione Preventivazione e selezione modelli Dati certificazioni Dati CAD 2D 3D Informazioni sui prodotti Le informazioni sui nuovi prodotti vengono fornite sotto forma di documenti e filmati per ciascun nuovo modello lanciato Esse possono essere scaricate da una sezione privata del sito web aziendale Caratteristiche Notizie sui prodotti Brochure e tutti i manuali Video di promozione del prodotto Formazione per gli installatori Formazione General provvede alla formazione dei suoi installatori all installazione dei sistemi a portata variabile VRF e alla formazione di Centri di Assistenza Specializzati in questa tipologia di prodotti Caratteristiche e Progettazione sistemi AIRSTAGE Formazione in loco per il controllo dei sistemi Presentazione e formazione Assistenza tecnica In ogni fase dalla progettazione all istallazione viene fornita l assistenza tecnica per ottenere le soluzioni di climatizzazione pi idonee Caratteristiche e Simulazione Linee guida Assistenza alla messa in opera 009 Simulatore di progettazione ora di lasciare da parte carte e penne e di realizzare in modo facile ed immediato il progetto sul proprio computer grazie al simulatore di progettazione Ogni singolo aspetto dalla selezione delle unit interne ed esterne all assegnazione dei comandi e dei componenti opzionali
82. ia per un flusso uniforme dell aria Questa griglia stata progettata in modo aerodinamico per garantire la massima efficienza di scambio quello nominale Modalit rumore Modalit rumore Controllo inverter DC L efficienza migliorata grazie al montaggio di un nuovo modulo del filtro attivo Riduzione livello di rumore NN Motore compressore a efficienza elevata Design ottimizzato del flusso di refrigerante a Parti ad alta _ precisione Compressore rotativo Twin DC compatto e ad alte prestazioni L efficienza in tutte le condizionidi carico buona Prestazioni particolarmente soddisfacenti rispetto alle condizioni operative normali medie e basse Alto QD X tv O 8 Capacit 100 Alto compressore 023 Caratteristiche Lunghezza tubi La tecnologia d avanguardia per il controllo del refrigerante ci consente di ottenere una aan lunghezza totale del tubo per il refrigerante tubazioni pari a 80 m Questa soluzione apre a nuove 80 Max m possibilit nella progettazione del sistema Lunghezza massima Lunghezza effettiva della tubazione Max 50 m Differenza altezza tra unit esterne e interne Max 30 m Lunghezza delle tubazioni dal primo separatore di tubi all ultima unit esterna Max 40m Maggiore comfort Funzionamento continuo durante il recupero dell oli
83. istema di rete VRF C sS s M rete VRF singolo W hi D AB BD BC lt 500m Amplificatore di segnale Specifiche Specifiche Nome modello UTY TEKX Nome modello UTY VSGXZ1 Nome modello UTY VGGXZ1 Alimentazione elettrica DC 12V Alimentazione elettrica 208 240V 50 60Hz monofase Alimentazione elettrica 208 240V 50 60Hz monofase Dimensioni A x L x P mm 120 x 75 x 30 Consumo elettrico W 4 5 Consumo elettrico W 6 5 Peso g 100 Dimensioni A x L x P mm 67 x 288 x 211 Dimensioni A x L x P mm 67 x 288 x 211 La DC 12 V viene erogata dall unit interna Peso g 1 500 Peso g 1 500 070 071 Assistenza e manutenzione 072 Max Service Tool UTY ASGX y moniorabil e controllabili a PU Max Funzioni speciali di monitoraggio e analisi per l installazione e la manutenzione 100 unit interne monitorabili eLo stato operativo pu essere controllato e analizzato per rilevare anche le minime anomalie Cj e controllabili Archiviazione dei dati sullo stato operativo del sistema sul PC che consente l accesso anche da fuori sito possibile controllare e monitorare fino a 400 unit interne sistema di rete VRF singolo per hotel o edifici di grandi dimensioni Questo software pu essere collegato a qualsiasi punto della linea di trasmissione con l adattatore USB da reperire su campo Collegamento Service Tool i Tubazioni refrigerante S E E
84. istiche La curva di carico dell edifico va dal 40 al 80 del carico massimo Di conseguenza la maggior parte dei condizionatori d aria non funziona a carico massimo ma solo a carichi medio bassi In particolare per i sistemi multipli le prestazioni a carichi parziali sono importanti in quanto i condizionatori d aria non operano sempre a carico massimo Pensando alle prestazioni di risparmio energetico corrispondenti alle operazioni effettive General ha elaborato un condizionatore d aria ad alte prestazioni che corrisponde non solo alle prestazioni classificate a un carico del 100 95 ma anche ad un livello medio basso Curva di carico tipico edificio adibito ad uffici Carico edificio 96 0 3 6 9 12 15 18 21 24 Tempo h EER COP elevato 4 29 4 20 3 72 n 4HP 5 HP Mem eer P corp Prestazioni elevate a carico parziale usse eur 66 50 46 50 5 73 iuis 5 75 m y lt Li niente EER COP raffreddamento riscaldamento Condizioni Unit interne collegate AUXA30GALH AUXD24GALH Raffreddamento temp interna di 27 CDB 19 CWB temp esterna di 35 CDB 24 CWB Riscaldamento temp interna di 20 CDB 15 CWB temp esterna di 7 CDB 6 CWB Potenza elevata in riscaldamento Capacit di riscaldamento KW Serie J Il 6HP La capacit di riscaldamento risulta k L_ migliorata a temperature esterne basse grazie alla nostra te
85. it mangoa 22 4 28 0 33 5 40 0 45 0 50 4 56 0 61 5 67 0 73 0 78 5 85 0 123 5 130 0 135 0 Aea a 25 0 31 5 37 5 45 0 50 0 56 5 63 0 69 0 75 0 81 5 87 5 95 0 137 5 145 0 150 0 Potenza ana 5 45 7 11 9 75 11 34 13 61 12 56 14 22 16 86 19 50 20 72 23 36 24 95 36 97 38 56 40 83 d ingresso C WW 2554 2657 2886 2972 3201 3287 3546 3644 3831 EER Raffredda W W 4 01 3 94 3 65 3 44 3 41 3 31 3 57 3 44 3 50 3 38 3 34 3 37 3 31 COP Prod W W 4 34 4 30 4 07 3 90 4 01 3 92 4 01 3 90 4 00 3 91 3 91 3 98 3 92 Portata flusso dell aria m h 11 100x2 11 100x2 11 100x2 11 100x2 13 000 11 100 13 000 11 100 13 000x2 13 000x2 11 100x3 11 100x3 13 000 11 100x2 13 000 11 100x2 13 000x2 11 100 13 000x2 11 100 13 000x3 13 000x3 Livello pressione Raffredda dB A 60 61 62 62 64 64 63 64 64 65 65 65 66 sonora rc 58 59 61 61 61 62 62 63 64 63 64 64 64 65 66 65 66 65 66 66 66 Pressione statica esterna massima 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 80 Potenza nominale compressore 7 5 7 5 7 5 11 0 11 0 7 5x2 7 5x2 7 5x2 7 5x2 11 0 7 5 11 0 7 5 11 0x2 11 0x2 7 5x3 7 5x3 11 0 7 5x2 11 0 7 5x2 11 0x2 7 5 11 0x2 7 5 11 0x3 11 0x3 Scambiatore di calore Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Blue fin Altezza 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 1 690 Dimensioni Larghezza 1 240 930 1 240 930 1 24
86. limenti Fujitsu General sono dotati della certificazione ISO 9001 e hanno elaborato un sistema di controllo qualit comune per tutti gli stabilimenti del mondo I prodotti di qualit vengono offerti a tutto il mondo dopo aver superato severi ispezioni sulla qualit Ispezione alla ricezione L approvvigionamento delle parti richiede il test sui collaudi del fornitore Inoltre vengono effettuate le ispezioni in base alla normativa europea RoHS da parte di un reparto di collaudo speciale interno all azienda Le ispezioni sui numeri totali vengono eseguite in modo particolare sulle parti principali cos da rimuovere quelle eventualmente difettose Severe ispezioni sulla qualit dei prodotti Le severe ispezioni sulla qualit dei prodotti vengono svolte sull intero processo produttivo L alta qualit viene mantenuta grazie a controlli severi da parte di ispettori e attraverso ispezioni ripetute nel tempo Dotazione della Parti e materiali e Ispezione bilanciatore Assemblaggio Ispezioni qualit prodotti Ispezione resistenza pressione Ispezione presenza crepe e perdite Seconda ispezione presenza crepe e perdite Resistenza isolamento Ispezione Tensione di tenuta Ispezione Resistenza isolamento ispezione Tensione di tenuta ispezione Parti e materiali ga a ims Ispezione produzione calore Ispezione suoni anomali certificazione ISO 9001 e I
87. mensioni 042 8 10 12HP AJHA72GALH AJHA90GALH AJH108GALH 690 Passo del bullone 1576 14 16HP AJH126GALH AJH144GALH 80 530 Passo del 8 12x 17 Foro bullone Ko O o 6 alge 2 mio r oO e O o 1000 Passo del bullone 840 Passo del bullone 8 12x7 Foro Z MZ NE SS Nim 732 Passo del s ti l LA Posizione separatore lato frontale 34 5 Porta cavo alimentazione 43 7 Porta cavo alimentazione D 22 2 Porta cavo trasmissione Porta cavo alimentazione D 22 2 Porta cavo trasmissione 1690 D Posizione separatore lato sinistro A 34 5 orta cavo alimentazione 43 7 Porta cavo alimentazione D 50 Porta cavo alimentazione 22 2 Porta cavo trasmissione 22 2 Porta cavo trasmissione C si E Posizione separatore lato inferiore Vista dall alto Porta tubo 044 Specifiche unit esterne Combinazione in funzione dell economia di spazio
88. o Una condizione confortevole in ambiente viene mantenuta durante la modalit di recupero dell olio in quanto il prodotto continua ad operare senza dover arrestare le operazioni di raffreddamento o riscaldamento Modello precedente Serie J Il Funzione di riscaldamento Interruzione funzionamento per Funzionamento continuativo durante il recupero dell olio recupero olio ACCESO SPENTO EET ACCESO Tempo Tempo 024 Differenza altezza tra unit interne Max 15m Installazione facilitata Funzione controllo collegamenti possibile verificare se il collegamento dei cavi e le impostazioni degli indirizzi sono corrette tramite la funzione di controllo rapido PEL rnm Ha Cs ki aue TER Numeri unit interne collegate a display E possibile visualizzare i numeri di indirizzo impostati in duplicato per le unit interne Specifiche Range di potenza HP 4 5 6 Nome modello AJHOAOLCLAH AJHOA5LCLAH AJHO54LCLAH Livello massimo unit interna collegabile 7 8 8 Alimentazione VIDIHZ 230 1 50 230 1 50 230 1 50 Raffredda Capacit mento kW 12 1 14 0 15 1 da 13 6 16 0 16 5 Raffredda 3 44 4 43 5 32 mento Potenza d ingresso Riscplda kW 3 09 3 03 4 26 EER Rete w 3 16 2 84 COP Risga 4 40 4 07 3 87 Portata flusso dell aria m3 h 4 040 4 200 4 200 Livello pressione Renee dB 51 53 54 sonora Pasa A 54 55 56 Scambiatore di calore
89. o 1 ora m Regolazione del limite superiore e inferiore della Timer programma e W temperatura impostata Tine A s e e N N NH N N m NH L intervallo della temperatura impostata pu essere regolato per ciascuna Giornata di ferie amp e gt e o modalit operativa Raffreddamento riscaldamento automatico Impostazione unit minima del timer 10 30 30 30 30 5 10 10 10 10 10 Minuti Sistema di monitoraggio di stato e e Distribuzione rete elettrica E Q Cronologia errori e e o e e Arresto di emergenza e Gestione remota z z e Z O e Specifiche Gestione risparmio energetico _ Z Da E Q Q Nome modello UTY RNRG Notifica e mail per malfunzionamento e Alimentazione CC 12V e Dimensioni A x L x P mm 120 x 120 x 20 4 Blocco tasti Blocco Blocco m m m Blocco Impostazione Impostazione Impostazione Impostazione Peso g 220 bambini bambini bambini password password password password 9 1 L impostazione Modalit operativa non disponibile per questo modello Supportata QO Funzione Opzionale La CC12 V viene erogata dall unit interna 2 Questa funzione unicamente disponibile solo tramite il controllo di ingresso esterno Non ancora supportata 054 055 Dispositivi di controllo Max unit 16 Dispositivo di controllo remoto con filo UTY RLRG ee ____un Unit interne
90. o Alimentazione elettrica Dimensions H x W x D mm Alta visibilit e operazioni facilitate Le voci Modalit Imp temp Ventola vengono visualizzate a caratteri grandi sullo schermo in alto A ciascuna funzione da impostare corrisponde un icona La guida all utilizzo dei vari controlli viene visualizzata e le operazioni sono facili e intuitive I contenuti impostati possono essere visualizzati in modo pi chiaro grazie al LCD Tasti di controllo sofisticati Operazioni facilitate grazie al pad di navigazione con 4 direzioni Ritorno automatico impostazione temperatura La temperatura impostata ritorna automaticamente alla temperatura impostata in precedenza The time range in which the set temperature can be changed is 30 to 120 minutes Operazioni di raffreddamento Operazioni di riscaldamento Impostazione temp Impostazione temp Cambiamento impostazione temperatura Ritorno automatico Cambiamento impostazione temperatura Ritorno automatico Y Y 25 C Y Y 24 C Fascia oraria ED impostabile da 30 a 120 minuti Fascia oraria impostabile da 30 a 120 minuti AM11 40 PM1 40 Orario AM11 40 PM1 40 Orario Regolazione del limite superiore e inferiore della temperatura impostata L intervallo della temperatura impostata pu essere regolato per ciascuna modalit operativa Raffreddamento riscaldamento automatico Durante il raffreddamento Durante il ri
91. o dell interruttore esterno amp ell dispositivo di controllo remoto standard e il dispositivo di controllo remoto centralizzato consentono l accensione e lo spegnimento il controllo generale Unit AO S Nota tutte le unit interne funzionano con la stessa modalit T2 Riscaldamento Interna E scheda il controllo su temperatura e ventola ELCs conto gresso fornita su E possibile utilizzare un singolo convertitore di rete per collegare e controllare fino a 16 unit singole remoto SL campo T1 ON T2 OFF Ora Dispositivo di controllo interruttore esterno m Nota 1 Int sensore g Selezionare un interruttore Cohvertitor dirate e termosensore impostabile per T1 e T2 Int sensore mi mi m da da dan fornito su campo Unit re 27 Inr e s Int sensore nterna Ce SW1 SW2 fornito d Ingresso su campo B d Nota 2 Wm Il funzionamento del dispositivo di controllo lt A contatto individuale Dispositivo di controllo interruttore esterno da remoto precedente al funzionamento Dispositivo di controllo interruttore esterno asciutto UTY TEKK in modalit automatica ia da Gruppo di monosplit T LJ Sistema di Adattatore rete VRF USB I Dispositivo di controllo sistema Monosplit au e Je Am Jul Amplificatore di seg nale UTY VSGXZ1 Rivolg
92. ome e forma Applicazione DVD ROM Include software e manuali per gateway BACnet WibuKey Chiave protezione software da collegare alla porta USB su BACnet Installaz PC Chiave protezione software Il gateway BACnet lavora solo su PC dotati di chiave Wibu Il PC deve essere fornito su campo L interfaccia di rete UTO USB deve essere fornita su campo Contattare Echelon Corporation o i suoi rappresentanti locali per ulteriori informazioni Nome prodotto Interfaccia rete U10 USB TP FT 10 canali Numero modello 75010R Num max controllabile 4 Convertitore direte per LONWORKS UTY VLGX i unit suBMS Num max controllabile 128 unit interne e Per il collegamento tra il sistema di rete VRF e una rete apertaLoNWoRks per la gestione di sistemi piccoli medi di rete VRF e BMS UTY VLGX consente il monitoraggio centrale e il controllo di un sistema di rete VRF da un BMS attraverso una interfaccia LONWORKS e possibile collegare fino a 128 unit interne ad un convertitore di rete per LoNWORKS Esempio di installazione Max 128 unit interne Max 4 convertitori di rete Scopi generici computer controllo edificio LONWORKS dispositivo Unit RB I 1 s vy vu Sistema di rete VRF 1 z Dispositivi di illuminazione Max 128 unit interne 4 Sistema sicurezza NA In
93. one dell economia di spazio 22 4 kW 8HP i w AJHA72GALH UNIT AJHA72GALH 28 0 kW 10HP E rr AJHA90GALH UNIT AJHA90GALH 33 5 kW 12HP E AJH108GALH UNIT AJH108GALH 40 0 kW 14HP AJH126GALH UNIT AJH126GALH 45 0 kW 16HP AJH144GALH UNIT AJH144GALH 50 4 kW 18HP H mm yh r AJH162GALH UNIT AJHA90 A72GALH 56 0 kW 20HP w yr lt AJH180GALH UNIT AJHA90 A90GALH 61 5 kW 22HP J w lt p AJH198GALH UNIT AJH108 A90GALH 67 0 KW 24HP AJH216GALH UNIT AJH108 108GALH 73 0 kW 26HP T wn j ee ir AJH234GALH UNIT AJH144 A90GALH 78 5 kW 28HP lt w T wF cQ AJH252GALH UNIT AJH144 108GALH 85 0 kW 30HP lt m AJH270GALH UNIT AJH144 126GALH 90 0 kW 32HP AJH288GALH UNIT AJH144 144GALH 95 0 kW 34HP x x m w T AJH306GALH UNIT AJH108 108 A90GALH 100 5 kW 36HP or wr AJH324GALH UNIT AJH108 108 108GALH 106 5 kW 38HP Em x x Cm ERR T o w AJH342GALH UNIT AJH144 108 A90GALH 112 0 KW 40HP E dm zm sie Pl IA AJH360GALH UNIT AJH144 108 108GALH 118 0 kW 42HP rr s w AJH378GAL UNIT AJH144 144 A90GALH
94. ool 5 L AO xw AO CA _ Mae UTY ASGX Unit interna Software Adattatore USB Fornita su campo Strumento di monitoraggio web UTY AMGX Software Monitoraggio ig um x 1 Internet o linea pubblica del telefono IKOE R264 1 u Lit de Diagnosi errori da parte del Service Tool Le informazioni dettagliate sullo stato dell unit dai modelli monosplit al sistema VRF possono essere verificate sullo schermo del PC collegando il Service Tool Inoltre possibile effettuare contromisurazioni in tempi rapidi Stato operativo controllo Monitoraggio condizione operativa Monitoraggio dati sensore Indicazione del grafico tendenze Cronologia errori Indicazione del diagramma circuito refrigerante per VRF Monitoraggio remoto Le informazioni in dettaglio sullo stato del sistema operativo VRF e sullo stato dei guasti pu essere costantemente monitorato da remoto tramite Internet ecc Inoltre possibile richiedere la collaborazione rapida del personale tecnico addetto alla manutenzione e riparazione 013 _ AIRSTAGE CARATTERISTICHE PRINCIPALI NOVITA Sistemi per grandi abitazioni e per uffici e Sistemi per grandi abitazioni e per uffici e negozi di medie dimensioni negozi di medie dimensioni 3 modelli 4HP 5HP 6HP 3 modelli 4HP 5HP 6HP ARSTAGE J S ARSTAGE Composizione unit interne Range capacit da 1 1 kW fino a 25
95. pecifiche Lunghezza tubi La tecnologia d avanguardia per il controllo del refrigerante ci consente di ottenere una lunghezza totale delle tubazioni del refrigerante pari a 80 m Questa soluzione apre a nuove possibilit nella progettazione del sistema II Lunghezza effettiva delle tubazioni T Max 120m P Lunghezza tubazioni dal primo tubo di separazione all unit interna pi lontana Max 40m Maggiore comfort Funzionamento continuo durante il recupero dell olio Una condizione confortevole in ambiente viene mantenuta durante la modalit di recupero dell olio in quanto il prodotto continua ad operare senza dover arrestare le operazioni di raffreddamento o riscaldamento Modello precedente Serie J Il Funzione di riscaldamento Interruzione funzionamento per I i ali recupero ARA p Funzionamento continuativo durante il recupero dell olio ACCESO ACCESO SPENTO PPP a Tempo Tempo 028 Lunghezza totale delle tubazioni Max 180 m Differenza altezza tra unit esterne e interne Max 30 m Lunghezza tubazioni dal primo tubo di separazione all unit interna pi lontana Max 15m Installazione facilitata Funzione controllo collegamenti possibile verificare se il collegamento dei cavi e le impostazioni degli indirizzi sono corrette tramite la funzione di controllo rapido Numeri unit interne colleg
96. plicabili Software Internet Explorer 8 0 or 9 0 or 10 0 Adobe Reader 9 0 o successiva Unit ottica Unit DVD ROM Elenco imballaggio Nome e forma Quantit Applicazione DVD ROM 1 Include software e manuali Chiave Wibu 1 Chiave protezione software da collegare alla porta USB sul Service Tool installaz PC Chievo pne lee sno Questi prodotti funzionano unicamente su PC dotati di chiave Wibu I PC deve essere fornito su campo L interfaccia di rete UTO USB deve essere fornita su campo Contattare Echelon Corporation o i suoi rappresentanti locali per ulteriori informazioni Nome prodotto Interfaccia rete UTO USB TP FT 10 canali Numero modello 75010R 073 Unit collegamento Separatori di tubi Tubo del gas Tubo del gas Tubo del gas Tubo del gas Tubo del liquido Tubo del liquido Tubo del liquido Tubo del liquido ana Neb LL LL Lee eem UTP AX054A UTP AX090A UTP AX180A UTP AX567A Tubo suzione gas _ Tubo suzione gas Tubo suzione gas ym Tubo scarico gas D Tubo scarico gas Tubo scarico gas jum Tubo del liquido Tubo del liquido Tubo del liquido UTP BX090A UTP BX180A UTP BX567A Kit diramazione unit esterna Tubo del gas Tubo del gas E adi Tubo del liquid ubo de AT Tubo del liquido Tra UTR H0908L UTR H1808L UTP CX567A Tubo gas RU Tubo gas scarico ST Tubo liquidi Collettori Tubo nn EEN Tubo del TT UTR H0906L UTR H1806L Tubo gas z s T
97. quelle indicate di seguito Combinazione per risparmio dello spazio Dimensioni 22 4 KW 8HP 28 0 KW 10HP 33 5 KW 12HP 40 0 KW 14HP 45 0 KW 16HP AJHA72LALH AJHA90LALH AJH108LALH AJH126LALH AJH144LALH UNIT AJHA72LALH UNIT AJHA90LALH UNIT AJH108LALH UNIT AJH126LALH UNIT AJH144LALH 50 4 KW 18HP 55 9 KW 20HP 61 5 KW 22HP 67 0 KW 24HP 73 5 KW 26HP AJH162LALH AJH180LALH AJH198LALH AJH216LALH AJH234LALH UNIT AJHA90 A72LALH UNIT AJH108 A72LALH UNIT AJH108 A90LALH UNIT AJH108 108LALH UNIT AJH126 108LALH 78 5 KW 28HP 85 0 KW 30HP 90 0 KW 32HP 95 0 KW 34HP 100 5 KW 36HP L fU UH ef ui C C gr i AJH252LALH AJH270LALH AJH288LALH AJH306LALH AJH324LALH UNIT AJH144 108LALH UNIT AJH144 126LALH UNIT AJH144 144LALH UNIT AJH108 108 A90LALH UNIT AJH108 108 108LALH 107 0 kW 38HP 112 0 kW 40HP 118 5 kW 42HP 123 5 KW 44HP 130 0 kW 46HP AJH342LALH AJH360LALH AJH378LALH AJH396LALH AJHA14LALH UNIT AJH126 108 108LALH UNIT AJH144 108 108LALH UNIT AJH144 126 108LALH UNIT AJH144 144 108LALH UNIT AJH144 144 126LALH 135 0 kW 48HP AJHA32LALH UNIT AJH144 144 144LALH Combinazione per l efficienza energetica 44 8 KW 16HP 62 4 KW 22HP 67 2 KW 24HP 72 8 KW 26HP 78 3 KW 28HP AJH144LALHH AJH198LALHH AJH216LALHH AJH234LALHH AJH252LALHH UNIT AJHA72 A72LALH UNIT AJH126 A72LALH UNIT AJHA72 A72 A72LALH
98. raffredd FUNZION riscald sussmeee Fupz ventola riscald Particolarmente indicato vio per le soluzioni di E e recupero del calore Riscaldamento Raffreddamento Deumidificazione Ventilazione 017 Flessibilit di design Elevato range di Capacit AIRSTAGE Serie J IIS 4HP 6HP Tipo pompa di calore Intervallo capacit unit interna collegabile dal 50 al 130 Numero unit interne collegabili fino a 8 AIRSTAGE Serie J Il 4H P 6H P Tipo pompa di calore intervallo capacit interne collegabili dal 50 al 13096 Numero unit interne collegabili fino a 9 Ampio Range operativo 8H P 48H P AIRSTAGE Serie V II AIRSTAGE Serie VR II Tipo pompa dicalore Versione recupero calore Intervallo capacit unit Intervallo capacit unit interna collegabile interna collegabile dal 50 al 15096 dal 50 al 15096 Numero unit interne Numero unit interne collegabili collegabili fino a 48 fino a 64 1 Condizioni di livello massimo di capacit dell unit interna come da tabella seguente 2 Solo 4HP al 46 Livello massimo di capacit dell unit interna collegabile Capacit unit esterna Modelli senza 1 1 kW Modelli con 1 1 kW 3 8HP 48HP 150 130 4HP 6HP 130 120 3 Nel caso di unit interne collegabili i modelli 1 1 KW e cassetta e o tipo di canalizzabile di classe 9 0 kW o superiore il livello m
99. scaldamento 30 C 30 C 25 C 25 C 18C _______ 16C ______r Intervallo Impostazione Intervallo Impostazione impostazione limite inferiore impostazione limite superiore temp originaria temp originaria UTY RLRG CC 12V 120 x 120 x 17 Peso g 170 La CC12V viene erogata dall unit interna 056 Dispositivo di controllo semplice UTY RSKG UTY RHKG senza modalit operativa Max unita 16 Unit interne Il dispositivo di controllo remoto compatto garantisce l accesso alle m funzioni di base possibile controllare fino a 16 unit interne con un dispositivo di controllo remoto Indicato per hotel o uffici in quanto facilmente maneggiabile senza operazioni complesse Tipo a 3 fili Utilizzo facilitato Consente di effettuare le operazioni di base ad esempio avvio arresto controllo ventola selezione modalit operativa impostazione temperatura in ambiente tasto di accensione e spegnimento di grandi dimensioni ed collocato al centro del dispositivo di controllo remoto cosi da garantire un utilizzo facilitato Utilizzabile insieme ad altre unit con controllo individuale Quando viene visualizzato un errore la diagnostica pu essere effettuata sul dispositivo di controllo Installazione facilitata Pu essere montato nella scatola di montaggio europea dimensioni di installazione 60mm o nella scatola integrata JIS Dimensioni di installa
100. scaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Tensione 230 V 1 questo valore in ciclo raffreddamento Parete Compatto Nome modello ASHA18GACH ASHA24GACH ASHA30GACH Alimentazione VIQDIHZ 230 1 50 Capacit Raffreddamento 5 6 7 1 8 0 Riscaldamento KW 6 3 8 0 9 0 Potenza d ingresso W 32 60 91 Portata flusso dell aria Alta 840 1 100 1 240 Media m3 h 770 910 980 Bassa 690 730 770 Livello pressione sonora Alta 41 48 52 Media dB A 39 43 45 Bassa 35 35 35 Dimensioni A x L x P mm 320 x 998 x 228 Peso kg 15 Diametro linee Liquido svasato 29 52 frigorifere Gas svasato mm 015 88 Tubo di scarico 412 D l 916 D E Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Tensione 230 V 051 Dispositivi di controllo Presentazione sistema di controllo Controlli centralizzati Le necessit dell utente vengono supportate offrendo una ampia gamma di soluzioni di controllo tra cui controllo individuale controllo centrale nonch
101. scaldamento 6 3 8 0 Potenza d ingresso W 74 99 Portata flusso dell aria Alta 1 000 1 000 Media m h 720 820 Bassa 580 680 Livello pressione sonora Alta 46 47 Media dB A 39 42 Bassa 35 37 Dimensioni A x L x P 199 x 990 x 655 Peso kg 25 26 26 27 Diametro linee Liquido svasato 26 35 29 52 frigorifere Gas svasato mm 612 70 015 88 Tubo di scarico VP25 925 D l 232 D E Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m Tensione 230 V Soffitto Nome modello ABHA30GATH ABHA36GATH ABHA45GATH ABHA54GATH Alimentazione VIDIHZ 230 1 50 Capacit Raffreddamento kW 12 5 14 0 Riscaldamento 14 0 16 0 Potenza d ingresso W 131 180 Portata flusso dell aria Alta 2 010 2 270 Media m3 h 1 600 1 780 Bassa 1 230 1 280 Livello pressione sonora Alta 42 45 48 51 Media dB A 38 38 42 45 Bassa 33 34 35 36 Dimensioni A x L x P mm 240 x 1 660 x 700 Peso kg 46 48 Diametro linee Liquido svasato 29 52 29 52 frigorifere Gas svasato mm 2015 88 219 05 Tubo di scarico VP25 925 D I 932 D E Nota le specifiche si basano sulle condizioni seguenti
102. ssione statica esterna di 80 Pa Questo consente l installazione delle unit esterne sui balconi ecc in corrispondenza di ciascun piano di stabilimenti molto alti Scambio altamente efficiente con una pressione statica esterna di 80 Pa 80 Pa come standard Serie V II Modello precedente La ventola a diametro grande e il motore CC sono stati utilizzati cosi da consentire una pressione statica esterna di 80 Pa Essa all incirca 2 6 volte pi grande rispetto al modello precedente Lunghezza totale delle tubazioni Max 1 000 m 1 Nota Dove presente 1 unit esterna il massimo 700m iu Differenza altezza tra unit esterne e interne Max 50m Per le unit esterne indicate di seguito 40m max Differenza altezza tra unit interne Max 15m Esempio di installazione Collegamento flessibile delle tubazioni Un sistema di tubazioni pi flessibile per il passaggio del refrigerante possibile grazie all impiego di vari collegamenti tra le unit esterne il box RB e unit interne Applicazione Max 308 unit interne I Tubo di separazione Unit RB Tipo multiplo m A f Qt i Norm ORA ORA Csi Gi i i ue Gis e X VET L Max 8 unit interne L unit RB pu essere liberamente posizionata tra la prima diramazione e l unit interna La differenza massima di altezza tra le unit RB 15 m
103. sterna lili mt OIOJ O O O OJO Gestione rispa rmio energetico per dispositivo di controllo sistema UTY PEGX risparmio Registro operazioni risparmio energetico per dispositivo di controllo sistema Lite UTY PLGXE1 xu ues ER E onitoraggio consumo elettrico possibile impostare una ampia gamma di operazioni di risparmio S e D DE i Operazione riduzione picchi Importazione esportazione database energetico da gestire in base alla stagione al tempo e all orario i x Altro Regolazione automatica dell orologio i Vengono svolte ottime operazioni di risparmio energetico mentre Il contatore viene collegato per rilevare il consumo totale di energia Multi lingue 7 lingue 7 lingue all utente costantemente garantito il massimo comfort durante il cambio della temperatura impostata per l unit interna il O Disponibile Non disponibile termostato dell unit interna viene disattivato in modo forzato e vengono L applicazione di calcolo energetico necessaria rivolgersi al rappresentante locale di FGL um effettuate le altre misurazioni per controllare l energia consumata mentre viene garanti il massimo comfort e si effettuano i controlli per mantenere costante il Requisiti di sistema del PC consumo stabilito di energia ogni volta Intervallo blocco termostato forzato Microsoft Windows Vista Home Premium 32 bit SP2 Windows Vista Business 32 bit SP2 Le unit interne
104. sterna 0 m 1 questo valore in ciclo raffreddamento Nome modello ARXA24GBLH ARXA30GBLH ARXA36GBLH ARXA45GBLH Alimentazione VIDIHZ 230 1 50 Capacit Raffreddamento 74 9 0 11 2 12 5 Riscaldamento KW 8 0 10 0 12 5 14 0 Potenza d ingresso W 94 108 194 240 Portata flusso dell aria Alta 1 280 1 410 1 840 1 970 Media m3 h 990 1 280 1 600 1 860 Bassa 840 1 150 1 470 1 640 Intervallo pressione statica da 0 a 150 da 0 a 150 da 0 a 150 V Pressione statica standard Pa 40 50 50 60 Livello pressione Alta 31 34 37 41 sonora Media dB A 27 32 35 38 Bassa 23 29 33 36 Dimensioni A x L x P mm 270 x 1 135 x 700 Peso kg 36 40 Diametro linee Liquido svasato mm 29 52 frigorifere Gas svasato 215 88 219 05 Tubo di scarico VP25 225 D l 932 D E Nota le specifiche si basano sulle condizioni seguenti Raffreddamento temperatura interna di 27 CDB 19 CWB e temperatura esterna di 35 CDB 24 CWB Riscaldamento temperatura interna di 20 CDB 15 CWB e temperatura esterna di 7 CDB 6 CWB Lunghezza tubo 7 5 m differenza altezza tra unit interna e unit esterna 0 m 049 050 Specifiche unit interne Canalizzato ad alta pressione statica Parete Compatto Nome modello ARXC36GATH ARXC45GA
105. su piccola j 400 e su grande scala possibile controllare fino ad un massimo di 4 sistemi di rete VRF 1600 unit interne e 400 unit esterne unit esterne Num max controllabile e In aggiunta alla funzione di controllo di precisione sul condizionamento dell aria le funzioni di 1 600 controllo remoto centralizzato di calcolo della carica elettrica di gestione dei programmi e unit interne risparmio energetico sono rafforzate cos da rispondere alle esigenze dei proprietari e dei gestori degli edifici Disponibile in 7 diverse lingue inglese cinese francese tedesco spagnolo russo polacco Num max controllabile Dispositivo di controllo sistema Lite UTY ALGX sistemi di rete NOVIT j Num max controllabile Il dispositivo di controllo sistema Lite presenta funzioni standard sufficienti Ed unit esterne per la gestione del condizionatore d aria in edifici di piccola media scala TA Num i Pn st C controllabils E possibile controllare fino ad un massimo di 1 sistemi di rete VRF 400 unit interne e 100 400 unit esterne Oltre ala funzione di controllo di precisione del condizionamento dell aria disponibile una unit interne ampia gamma di software opzionali per la gestione cos da offrire agli utenti una scelta pi completa Disponibile in 7 diverse lingue inglese cinese francese tedesco spagnolo russo polacco
106. telefono Adattatore USB da reperire su campo Unit interna adattatori USB Supporta 4 sistemi VRF L adattatore USB max 4 adattatori per PC consente il monitoraggio di max 1 600 unit interne Soluzione indicata per hotel e edifici di grandi dimensioni H mi A Sistema di rete Sistema di rete Sistema di rete Sistema di rete VRF 1 VRF 2 VRF 3 VRF 4 Max 400 Max 400 Max 400 Max 400 Unit interne Unit interne Unit interne Unit interne Requisiti di sistema del PC UTY AMGX e Microsoft Windows Vista Home Premium 32 bit SP2 Windows Vista Business 32 bit SP2 Microsoft Windows 7 Professional 32 bit o 64 bit SP1 m EM E Microsoft Windows 8 Pro 32 bit o 64 bit CPU 1 GHz o maggiore Memoria For Windows Vista Windows 7 32 bit e Windows 8 32 bit 1 GB o maggiore For Windows 7 64 bit e Windows 8 64 bit 2 GB o maggiore HDD Spazio libero maggiore o uguale a 40 GB Display Risoluzione maggiore o uguale a 1024 x 768 Porta Ethernet per accedere a Internet usando la LAN o Modem per accedere a Internet usando la linea pubblica telefonica Porte USB Max 5 porte Interfaccia 1 porta USB necessaria per la chiave Wibu Max 4 porte USB sono necessarie per l interfaccia di rete Echelon U10 USB numero max di poter USB richieste dipende dalle configurazioni di sistema ap
107. terfaccia allarme automatico E antincendio B x 3 i Sistema ventilazione o Unit RB ca m Rete Sistema di rete VRF 2 LONWORKS Specifiche Dimensioni Unit mm Nome modello UTY VLGX Alimentazione elettrica 208 240V 50 60Hz monofase Consumo elettrico W 4 5 2 5 Dimensioni A x L x P mm 67 x 288 x 211 For M4x20Lscrews Peso g 1 500 o E Specifiche di trasmissione lato BMS zi E Velocit trasmissione 78 kbps 2 2 Transricevitore FT X1 Echelon Corporation LO Oo Forma modalit trasmissione Topologia libera i E cole pitch 67 Nessuno pol Meo 88 Resistore terminale Si attacca al terminale della rete 067 Adattatore e convertitore Interfaccia KNX FJ RC KNX 1i g temen Q L interfaccia KNX consente la totale integrazione dei condizionatori d aria con i sistemi di rete KNX aF i Installazione facilitata grazie alle dimensioni piccole e compatte Non richiesta l alimentazione elettrica esterna solo alimentazione bus KNX Utilizzabile per unit interne singole e unit interne controllate a gruppi fino a 16 L interfaccia KNX pu essere usata con o senza Rete KNX P il dispositivo di controllo remoto con filo Dispositivo di controllo E da casa Di g Interfaccia KNX ispositivi di illuminazione VRF Unit interna Sistema m sicurezza x ec Interfaccia automati
108. ti di rumore 1 CFD Fluidodinamica computazionale Motore ventola DC 3 fasi DC produce livelli ridotti di rumore L efficienza dello scambio termico elevato ottenuta della proiezione interna Controllo inverter DC a onda sinusoidale L alta efficienza viene realizzata mediante l adozione di un IPM con perdite di commutazione ridotte Compressore ad alta efficienza Compressore con inverter DC a grande capacit Compressore rotativo Twin DC ad alta efficienza con una capacit intermedia eccellente Scambiatore di calore a 4 lati L efficienza dello scambiatore di calore risulta considerevolmente migliorata grazie all introduzione l area superficiale effettiva Distribuzione del refrigerante nello scambiatore di calore Lo scambiatore di calore suddiviso tra area superiore e area inferiore L efficienza dello scambio di calore risulta migliorata grazie al controllo ottimale sul refrigerante all interno del percorso dello scambiatore di calore Il refrigerante risulta maggiormente distribuito sulla sommit laterale dello scambiatore di calore con l assunzione di un flusso d aria di grandi proporzioni Controllo altamente efficiente sul flusso del refrigerante Ventola Flusso Assunzione di refrigerante flusso d aria di maggiori di grandi LJ proporzioni proporzioni Assunzione di flusso d aria di basse proporzioni Scambiatore di calore Distributore
109. troller e VRF Explorer pu essere eseguito Un massimo di in un PC singolo o in pari PC separati dalla rete Utilizzando il software 10 luoghi ad esempio VRF Explorer un PC pu svolgere il controllo centralizzato di 10 siti Uli O l dotati di sistema VRG con max 20 edifici per sito 91 eo Visualizzazione ad albero Visualizzazione gruppo Notifiche errori Controllo centralizzato presso il sito n Internet o Gestione Max 4 sistemi di rete VRF per sito sia EM Segnale di allarme acustico o LAN Notifica errore via e mail 2 EE EH EN EE EH EN EH EH EN Cronologia errori Cronologia Cronologia operazioni Cronologia controllli Acceso Spento Modalit operativa Temperatura in ambiente Velocit ventola o 1 VRF Controller pu essere monitorato da qualsiasi numero di Ere s Cuma Modalit risparmio energetico VR Eep orei di VRF Explorer fino as collegamenti in contemporanea Controllo Limitazione punto impostato temperatura ambiente Schermo di monitoraggio Explorer VRF lean operazioni Test operativo centralizzato Incaricata del turno diurno Anticongelamento per tutte le propriet Explorer VRF lo Impostazione blocco dispositivo di controllo remoto SR Explorer VRF Centro gestione uffici Internet o linea pubblica del telefono Controllo individuale Gestione individuale Regolazion
110. ubo gas scarico TS Tubo TO UTP J0906A UTP J1806A Tubo gas aspirazione Tubo gas scarico I Tubo liquidi UTP J0908A UTP J1808A UTP DX567A Per modello compatto montato a parete tu Model code 09 UTR EVO9XB Model code 12 UTR EV14XB UTP RX01AH UTP RX01BH UTP RX01CH UTP RX04BH Tipo singolo Tipo multiplo 074 Specifiche Separatori di tubi Nome modello UTP AX054A solo per J IIS UTP AX090A UTP AX180A UTP AX567A Capacit totale di raffreddamento dell unit interna KW 19 6 o inferiore 28 0 o inferiore da 28 1 a 56 0 56 1 o superiore Nome modello UTP BX090A UTP BX180A UTP BX567A Capacit totale di raffreddamento dell unit interna KW 28 0 o inferiore da 28 1 a 56 0 56 1 o superiore Collettori 3 6 diramazioni UTR H0906L UTR H1806L Nome modello Capacit totale di raffreddamento dell unit interna KW 28 0 o inferiore da 28 1 a 56 0 3 6 diramazioni UTP J0906A UTP J1806A Nome modello 3 8 diramazioni UTP J0908A UTP J1808A Capacit totale di raffreddamento dell unit interna KW 28 0 o inferiore da 28 1 a 56 0 Kit diramazione unit esterna Nome modello UTP CX567A per V II UTP DX567A per VR II 2 unit esterne 1 Numero unit esterna 3 unit esterne 2 Kit EV Nome modello UTR EVO9XB UTR EV14XB ASHE04GACH Modello applicazione ASHEO7GACH ASHEO9GACH ARME TACACR ASHE12GACH
111. um um um m Controllo refrigerante avanzato L innovativa logica di controllo del compressore stata introdotta per poter equilibrare il livello di flusso della massa refrigerante per ciascuna unit esterna controllando la velocit dell inverter ACCESO ACCESO ACCESO ACCESO SPENTO Principale Ausiliario1 Ausiliario 2 Livello Principale Ausiliario 1 Ausiliario 2 di carico Condizione operazioni Condizione operazioni bilanciamento sbilanciamento 5 Non disponibile per tutti modelli AIRSTAGE M Serie J IIS e J Il 019 Installazione facilitata Trasporto facile Facilmente trasportabile utilizzando cinghie di sollevamento con ganci Il design dell unit esterne consente l impiego di fasce di sollevamento Pu essere trasportato con un elevatore di piccole dimensioni Trasporto mediante carrello elevatore Cablaggio facilitato L installazione dei cavi facilitata in quanto possono essere installati in modo continuativo tra le unit interne esterne e RB Nota il collegamento seriale non pu utilizzare l impostazione di indirizzo automatico in un sistema di refrigerazione multiplo Collegamento in parallelo Impostazione indirizzo automatico Le impostazioni di indirizzo sull unit esterna automatico vengono riportate E MAP settet ANE
112. volmente migliorata grazie all introduzione del nuovo scambiatore di calore a 4 lati che aumenta l area superficiale effettiva Lato aspirazione aria frontale struttura di aspirazione dell aria ad angolo tagliato Nelle installazioni multiple di unit esterne il design esclusivo di aspirazione frontale migliora il flusso d aria nello scambiatore di calore 031 Caratteristiche Flessibilit di design Lunghezza totale delle tubazioni 1000 m La lunghezza massima delle tubazioni firgorifere sino a 1 000 m consente un ampia gamma di applicazioni Lunghezza totale delle tubazioni ii i Max 1000 m Differenza altezza tra unit esterne e interne Lunghezza effettiva Max 5 0 m delle tubazioni Max 150 m Se le unit esterne sono installate in basso Max 40 m Differenza altezza tra unit interne Max 15m Lunghezza tubazioni dal primo tubo di separazione all unit interna pi lontana Max 60m Pressione statica utile di 80 Pa L unit esterna pu essere facilmente collegata ad un condotto di espulsione aria grazie ad una pressione statica utile di 80 Pa Questo consente di installare unit esterne in locali interni canalizzando verso l esterno l aria di condensazione Esempio di installazione Pressione statica di 80 Pa 80 Pa come standard Modello precedente Serie V II La ventola a diametro grande e il motore DC sono stati utilizzati cos da cons
113. zione 83 5mm w nr Scatola interruttori europea Scatola integrata JIS 83 5mm CONDITIONER senza modalit operativa Retroilluminazione La retroilluminazione consente operazioni facilitate in ambienti oscurati La retroilluminazione si attiva con l utilizzo di tutti i tasti e dura 10 secondi in modalit operativa e 5 secondi in modalit di arresto una volta premuto il tasto Funzioni Modello Operazioni UTY RSKG Acceso Spento e e Controllo ventola e Modalit operativa e 1 Impostazione temperatura ambiente 1 L impostazione Modalit operativa non disponibile Si raccomanda l utilizzo insieme ad un altro dispositivo di controllo Specifiche Fonte di alimentazione DC 12V CC 12V Dimensioni A x L x P mm 120 x 75 x 14 120 x 75 x 14 Peso g 90 90 La CC12 V viene erogata dall unit interna 057 Dispositivi di controllo 058 Dispositivo di controllo wireless UTY LNHG Operazioni facili ma sofisticate grazie alla selezione di 4 timer giornalieri eUn dispositivo di controllo singolo in grado di controllare fino a 16 unit Num max controllabile 16 Unit interne Selezionabile 4 timer giornalieri Timer integrati Selezione da 4 diversi programmi per i timer Accensione Spegnimento Programma Notte Timer programma

Download Pdf Manuals

image

Related Search

Related Contents

Télécharger  Timing Advance Unit Remove Timing Advance Unit  DLP-6 speaker processor user manual - ENGLISH  XM-360 Process Module User Guide    取扱説明書 - 追補 - 428.72 KB  ORF Monitor user manual  Philips Harmony DCD7010/12 home cinema system  Manuale 655 KB 05.10.2012  取扱説明書  

Copyright © All rights reserved.
Failed to retrieve file