Home

IRIS LIR311K, LIR411K, LIR511K, LIR608K (V4) FARETTI

image

Contents

1. core To remove any deposit use a plastic layer like a phone card and a dry rag e Clean the lamps each time the boat is raised out of the water BINDING UNION srl www binding it MTU LIRx11KW V4 002 20100416 docx Binding Union marine amp automation instruments MANUALE TECNICO TECHNICAL MANUAL DIMENSIONI DIMENSIONS A B C 4 0 10 0 PERE in pee i 29 5 4 P D Cl oo Whe WTS ae Sp CA Tm TO Fig A cornice montaggio a incasso LIR311K Fig B cornice montaggio a parete LIR411K Fig C corpo centrale nudo LIR608K CARATTERISTICHE TECNICHE Alimentazione 10 30 Vcc Consumo max 4 W Angolo fascio luminoso 30 Sorgente luminosa 48 LED Protette contro l inversione di polarit Vita operativa 30000 ore Intensit luminosa max 432 lux dist 1m Temperatura operativa 10 60C Controllo luminosit opzione D 1 kHz PWM TTL compatibile Grado di protezione IP68 Contenitore policarbonato Dimensioni 110 x 22 5 mm Foro installazione mod da incasso 86 mm Peso 190 g LIR311K 210 g LIR411K 240 g LIR511K 160 g LIR608K OPZIONI e ACCESSORI Opzione D Ingresso da dimmer elettronico ACD001 Dimmer elettronico AV0417 Distanziale che consente il montaggio a parete connettendo elettricamente la lampada al di sopra della linea di galleggiamento evitando di forare lo scafo Quindi il cavo di alimentazione raggiunge la lampada lateralmente lungo la parete invece che pos
2. BJ Binding Union MANUALE TECNICO marine amp automation instruments TECHNICAL MANUAL IRIS LIR311K LIR411K LIR511K LIR608K V4 FARETTI SUBACQUEI UNDERWATER LAMPS Designed amp Produced e Non utilizzare avvitatori elettrici in Do not use power screwdrivers ITALY e Non utilizzare viti a testa svasata Do not use countersunk screws e Sigillare con Sikaflex 295 o 3M 4200 Seal with Sikaflex 295 or 3M 4200 DESCRIZIONE DESCRIPTION Luminosissime lampade a LED per esterni Very bright LED outdoor lamps suitable for adatte per immersione completa sotto la linea di installations below the water line completely galleggiamento Molto leggere robuste ed submerged Elegant with a small footprint and a eleganti hanno dimensioni contenute e very light weight they can be installed quickly consentono un installazione rapida Modelli per Models for surface and recessed mounting to be montaggio a parete o a incasso con fissaggioa fixed with three screws Ideal in engine rooms tre viti Ideali per plancette rollbar tendalini and outside the yacht to illuminate the sprayhood pozzetti vani motore cucine e bagni or cockpit area from rollbars and spreaders Long Lunga durata e basso consumo life and low power consumption LIR311K corpo centrale e cornice da incasso LIR311K core body and recessed frame LIR411K corpo centrale e cornice da parete LIR411K core body and surface frame LIR511K corpo centrale e due cornici incasso LI
3. O 1 Identificare il punto dove si desidera montare la lampada 2 Eseguire uno scasso con una punta a tazza da 86 mm di diametro 3 Inserire completamente il cavo di alimentazione nel foro appena eseguito 4 Far combaciare la lampada alla parete e ruotarla sino a raggiungere l orientamento desiderato 5 Inserendo la punta del trapano nei tre fori frontali presenti sulla cornice della lampada tracciare la posizione dei fori per le viti di fissaggio 6 Distaccare la lampada dalla parete e sfilare leggermente il cavo di alimentazione circa 30cm in modo da operare agevolmente 7 Sui segni tracciati eseguire tre fori di diametro 3 5 mm per le viti di fissaggio autofilettanti diam 3 9 mm a testa cilindrica 8 Inserire nei tre fori frontali della lampada le tre viti autofilettanti 9 Avvitare con cacciavite manuale senza forzare molto COLLEGAMENTI Le lampade dispongono di 2 m di cavo a tre poli Filo Rosso positivo batt Filo Nero negativo batt Filo Blu ingresso controllo luminosit da dimmer esterno attivo solo con opzione D Il collegamento elettrico va effettuato rispettando la polarit dei fili altrimenti le lampade non funzionano NOTE IMPORTANTI e Non utilizzare solventi sulla lampada o sulla cornice Vernici antivegetative e qualunque prodotto utilizzato a contatto con le lampade deve essere compatibile con il policarbonato e Per pulire la parte trasparente usare solo acqua per ri
4. R511K core body and both frames recessed e parete and surface LIR608K corpo centrale LIR608K core body only Nota Bene Nota Bene e Per montaggio subacqueo su scafo si e Only the surface mount models are suitable for raccomandano solo i modelli da parete underwater installations on the hull e codici menzionati non includono l ultima cifra The product codes mentioned above lack the che indica il colore della luce emessa last digit which specifies the colour of the light BINDING UNION srl www binding it MTU LIRx11KW V4 002 20100416 docx 1 BJ Binding Union marine amp automation instruments MONTAGGIO A PARETE USO SUBACQUEO 1 Identificare il punto dove si desidera montare la lampada ispezionare l interno dello scafo per evitare ostacoli strutturali 2 Tracciare ed eseguire un foro da 11 mm per il passaggio del cavo di alimentazione della lampada 3 Inserire completamente il cavo di alimentazione nel foro appena eseguito 4 Far combaciare la lampada alla parete e ruotarla sino a raggiungere l orientamento desiderato 5 Inserendo la punta del trapano nei tre fori frontali presenti sulla cornice della lampada tracciare la posizione dei fori per le viti di fissaggio 6 Distaccare la lampada dalla parete e sfilare leggermente il cavo di alimentazione circa 30cm in modo da operare agevolmente 7 Sui segni eseguire tre fori di diametro 3 5 mm per le viti di fissaggio 8 Riempire tre fo
5. ace and rotate it to the desired orientation Inserting the drill tip in each of the three front holes of the lamp frame mark the position of the front screws Take the lamp off and pull back the power cable for about 30 cm to be able to operate easily On the marks drill three 3 5 mm holes for the front screws Fill the three holes done on the surface with sealing gel Sikaflex 295 or 3M 4200 Generously deposit sealing gel on the rear side of the lamp and specifically around the screw holes and power cable Sliding the power cable back in completely align the lamp to the surface and make sure the three holes on the surface coincide with the ones on the lamp In the lamp front holes insert the three screws provided diam 3 9 mm length 32 mm cylinder head Nota Bene do not use countersunk screws Tighten the screws using a manual screwdriver without over doing it Clean up with a dry rag to remove any sealing gel left on the surface If the wall surface needs repainting wait 30 minutes at least Then protect the lamp by laying a tape around its frame Paint then remove the tape as soon as the painting is done the screws are provided with models LIR411 amp LIR511 only MONTAGGIO A PARETE SURFACE MOUNT Errato usare AVo417 Wrong use AV0417 instead BINDING UNION srl www binding it MTU LIRx11KW V4 002 20100416 docx Binding Union marine amp automation instruments MONTAGGIO A INCASS
6. muovere eventuali depositi si consiglia di usare una tessera telefonica 0 simile e un panno morbido e La pulizia v eseguita ogni volta cha l imbarcazione viene tirata a secco MANUALE TECNICO TECHNICAL MANUAL RECESSED MOUNT 1 Locate the exact point where the lamp will be mounted 2 Drill the recessed housing hole using an 86mm cup drill tip 3 Insert and slide the power cable completely in the hole just done 4 Align the lamp to the surface and rotate it to the desired orientation 5 Inserting the drill tio in each of the three front holes of the lamp frame mark the position of the front screws 6 Take the lamp off and pull back the power cable for about 30 cm to be able to operate easily 7 On the marks drill three 3 5 mm holes for the front screws diam 3 9 mm cylinder head 8 Insert the three screws in the lamp front holes 9 Tighten the screws using a manual screwdriver without over doing it CONNECTIONS The lamps feature a three pole cable 2 m long Red wire positive battery Black wire negative battery Blue wire external dimmer input active only with option D The lamps only work if connected following the right polarity No damage occurs if the connection is inverted IMPORTANT NOTES e Do not use solvents on the lamp core frame Paint antifouling and any other product used on the lamps must be compatible with polycarbonate e Use water only to clean the lamp transparent
7. ri eseguiti sulla parete con sigillante Sikaflex 295 oppure 3M 4200 9 Depositare il sigillante sul retro della lampada e in particolare attorno ai fori delle viti e del cavo di alimentazione in modo abbondante 10 Reinserendo completamente il cavo di alimentazione nel foro far combaciare la lampada alla parete e ruotarla sino a far coincidere tre fori eseguiti sulla parete con fori frontali della lampada 11 Inserire nei tre fori frontali della lampada le tre viti autofilettanti fornite diam 3 9 mm lunghezza 32 mm a testa cilindrica Nota Bene non utilizzare viti a testa svasata 12 Avvitare le tre viti con un cacciavite manuale senza forzare molto 13 Pulire con uno straccio asciutto l eventuale sigillante fuoriuscito sulla parete 14 Nel caso si debba riverniciare la parete attendere almeno 30 minuti e proteggere la lampada adagiando sul suo bordo un giro di nastro da rimuovere subito a fine verniciatura le viti sono fornite solo con i modelli LIR411 e LIR511 Corretto Correct Sigillante Sealing gel MANUALE TECNICO TECHNICAL MANUAL SURFACE MOUNT UNDERWATER USE 1 SA 11 12 13 14 Locate the exact point where the lamp will be mounted inspect inside the hull in order to avoid any obstacles Mark and drill an 11 mm hole for the lamp power cable Insert and slide the power cable completely in the hole just done Align the lamp to the surf
8. teriormente attraverso la parete OL He Fig A frame for recessed mount LIR311K Fig B frame for surface mount LIR411K Fig C central core body LIR608K TECHNICAL SPECIFICATIONS Power supply 10 30 Vdc Max power consumption 4 W Light beam angle 30 Light source 48 LED s Protected against polarity inversion Operating life 30000 hours Light intensity max 432 lux 1m distance Operating temperature 10 60 Dimming control option D 1 kHz PWM TTL compatible Protection class IP68 Case polycarbonate Dimensions 110 x 22 5 mm Dim of hole for recessed model 86 mm Weight 190 g LIR311K 210 g LIR411K 240 g LIR511K 160 g LIR608K OPTIONS and ACCESSORIES Option D Input from electronic dimmer ACD001 Electronic dimmer AV0417 Adapter that allows to surface mount the lamp and connect it above the water line without making any hole through the hull The power cable can therefore reach the lamp from the side running alongside the surface instead than from the rear through the surface BINDING UNION srl www binding it MTU LIRx11KW V4 002 20100416 docx