1. supplied screw and plug at a height between 2 10 m and 2 30 m from ground If necessary you can attach the detector directly to the wall or in the corner using the predrilled holes provided CONNECTIONS Connections with detector must be performed with shielded cable Connect the shield to the control panel earth leaving it unconnected on the detector side If the distance between detector and control panel is significant ensure there is no voltage drop Connections NC contatto normalmente chiuso di allarme TAMPER Normally closed antisabotage contact 24 h of the control panel and Power supply 8 16 Vdc PROGRAMMAZIONE Tramite il ponticello sfilabile jumper possibile programmare il rivelatore per due distinti modi di funzionamento JUMPER INSERITO AND la commutazione del rel avviene solo se entrambi i sensori rilevano contemporaneamente un intrusione JUMPER SFILATO OR l allarme viene inviato anche se a rilevare uno solo dei due sensori Nota la funzione OR garantisce una maggiore protezione ma aumenta notevolmente la possibilit di falsi allarmi soprattutto in ambienti difficili in ogni caso occorre regolare il trimmer relativo alla portata del sensore sens MW non oltre la zona da proteggere FUNZIONE DEI LED LED giallo lampeggiante la microonda sta rilevando del movimento nell ambiente LED verde acceso fisso il sensore infrarosso ha rilevato una presenza LED rosso acceso f
2. LINCESI LINCE ITALIA S p A ART ITEM 1630DT JOLLY 1 43DT JOLLY T 1830DT JOLLY E 187 9DT JOLLY TE DT JOLLY RILEVATORE DI PRESENZA A DOPPIA TECNOLOGIA Manuale di installazione programmazione ed uso Istruzioni originali GENI DISTRATTI RA Installation programming and operating manual Translation of original instructions SISTEM A A DI GESTIONE 6 CERTIFICATO G N 47 UNI EN ISO 9001 2008 MADE IN ITALY LINCE ITALIA S p A DESCRIZIONE I rilevatori DT JOLLY DT JOLLY T uniscono in un unico dispositivo un rilevatore a microonda ed un sensore ad infrarosso Appositamente studiato e realizzato per il funzionamento in ambienti difficili garantisce un elevato grado di immunit a fenomeni che in altri tipi di sensori possono causare falsi allarmi La sequenza dei preallarmi forniti dai due sensori in esso contenuti viene opportunamente analizzata dall elettronica evitando cos che fenomeni esterni come correnti d aria sorgenti di calore e disturbi di origine elettrica diano luogo ad allarmi indesiderati Facilmente adattabile a qualsiasi tipo di installazione sia a parete che ad angolo dotato di indicatori luminosi per la verifica del corretto orientamento e regolazione di sensibilit portata della microonda Una semplice impostazione dei modi di funzionamento AND ed OR ottenibile tramite un ponticello sfilabile jumper CARATTERISTICHE TECNICHE 1830DT OLLY E 1879D
3. T JOLLY TE i Oog O 70g Copertura orizzontale 90 6 INSTALLAZIONE rilevatori DT JOLLY DT JOLLY T offrono prestazioni ottimali ed una elevata immunit contro i falsi allarmi Anche se pi tollerante di altri sensori tradizionali consigliabile praticare una buona installazione attenendosi alle istruzioni Individuare il punto dove fissare il sensore valutando i punti di passaggio pi probabili L altezza consigliata di 2 2 m Per il fissaggio agire come segue e Togliere la copertura facendo pressione sulla clip di aggancio presente sul lato inferiore del rivelatore e passare il cavo attraverso lo snodo solo per articoli 1630DT JOLLY e 1830DT JOLLY E e fissare il supporto con la vite ed il tassello in dotazione ad un altezza da terra compresa tra i 2 10 m e i 2 30 m Se necessario possibile fissare direttamente il rilevatore a parete o ad angolo usando le preforature previste COLLEGAMENTI I collegamenti al rilevatore devono essere effettuati con cavo schermato collegare lo schermo alla massa della centrale lasciandolo scollegato dalla parte del sensore Se la distanza tra il rilevatore e la centrale notevole assicurarsi che non vi sia caduta di tensione Collegamenti NC contatto normalmente chiuso di allarme TAMPER contatto normalmente chiuso di antisabotaggio 24 h della centrale e alimentazione 8 16 Vcc DESCRIPTION The DT JOLLY DT JOLLY T detectors combines a mi
4. crowave detector and an infrared sensor in one device Especially designed and produced for operation in challenging environments it assures a high degree of immunity to phenomena that in other types of sensors may cause false alarms The sequence of pre alarms provided by the two sensors it contains is suitably analysed by electronics thus preventing external phenomena such as air drafts heat sources and electrical disturbances from triggering unwanted alarms Easily adaptable to any type of wall and corner installation it is provided with indicator lights for checking the correct orientation and sensitivity adjustment microwave range Simple setting of AND and OR operating modes can be obtained by means of a removable jumper TECHNICAL FEATURES 1830DT OLLY E 1879DT JOLLY TE Weight 709 709g Horizontal coverage go e INSTALLATION The DT JOLLY DT JOLLY T detectors offers optimal performance and high false alarm immunity Although it is more tolerant than other conventional sensors it is advisable to install it carefully following the instructions Locate the point where to secure the sensor after identifying the most likely waypoints The recommended height is 2 2 m For fastening act as follows e remove the cover by pressing the attachment clip on the underside of the detector e run the cable through the bracket only for items 1630DT JOLLY e 1830DT JOLLY E e secure the support with the
5. cted LED FUNCTION Yellow LED Flashing the microwave is detecting motion in the room Green LED Steady on the infrared sensor has detected a presence Red LED Steady on alarm condition COVERAGE The coverage of the protected area is determined by the combined effect of the two infrared and microwave sensors The microwave has a coverage angle of 90 on a horizontal plane while the infrared sensor within the same area has 24 4 level bundles each of which generates a differential signal The figure shows both the infrared sensor beams and by a continuous line the area covered by the microwave TEST COVERAGE In the environment where the detector has been installed perform a range test gradually increasing the microwave sensitivity via the trimmer range so as to switch on the yellow LED lights up to the limit of the area to be protected and not beyond N B The test coverage must be performed with the detector properly closed Grafico di copertura Covered area pattern Il grafico di copertura indica la posizione dei fasci dell IR La The range chart indicates the position of the IR beams The copertura della microonda di 90 microwave coverage is 90 Trimmer della portata mi 1 630 DT J O L LY sui ite croonda Jumper per la selezione 1830DT OLLY E della funzione AND o OR Di fabbrica Jumper inseri to AND Microwave range trimmer Jumper for selecting the AND or OR function Fac tory set Connec
6. isso condizione di allarme COPERTURA La copertura dell area protetta determinata dall effetto combinato dei due sensori infrarosso e microonda La microonda ha un angolo di copertura di 90 sul piano orizzontale mentre il sensore infrarosso all interno della stessa area dispone di 24 fasci su 4 livelli ognuno dei quali genera un segnale differenziale Nella figura sono riportati sia i fasci del sensore infrarosso sia mediante linea continua l area coperta dalla microonda PROVA DI COPERTURA Eseguire nell ambiente in cui installato il rilevatore una prova di portata aumentando gradualmente la sensibilit della microonda tramite il trimmer range al fine di ottenere l accensione del LED giallo fino al limite della zona da proteggere e non oltre N B La prova di copertura deve essere effettuata con il rivelatore perfettamente chiuso LINCE ITALIA S p A PROGRAMMING Through the removable jumper the detector can be programmed for two distinct modes JUMPER CONNECTED AND relay switching takes place only if both sensors simultaneously detect an intrusion JUMPER REMOVED OR the alarm is sent even if only one of the two sensors detects Note The OR function ensures increased protection but significantly increases the possibility of false alarms especially in difficult environments in any case when setting the sensor range sens MW via a trimmer do not extend range beyond the area to be prote
7. ted jumper AND VISTA LATERALE SIDE VIEW VISTA IN PIANTA Trimmer della portata micro 1743DT JOLLY T PLanvew onda Jumper per la selezione 1879DT JOLLY TE i della funzione AND o OR Di fabbrica Jumper inserito Microwave range trimmer Jumper for selecting the AND or OR function Fac tory set Connected jumper AND VISTA LATERALE SIDE VIEW Fig 2 LINCE ITALIA S p A Via Variante di Cancelliera snc 00040 ARICCIA Roma Tel 39 06 9301801 Fax 39 06 930180232 001530 00373AB info lince net www lince net